16
USER MANUAL EAR AND FOREHEAD THERMOMETER

USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

USER MANUAL

EAR AND FOREHEADTHERMOMETER

Page 2: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

PRODUCT STRUCTURE

(1) Probe cover

(2) Probe

(3) LCD display

(4) Power/ Measure

(5) °F/°C switch

(6) Mode(Adult/Child/Object)

(7) Battery cover

(8) Memory/Mute

5

1

6

7

4

3

2

8

Structure

Probe cover1

Cover on | Cover off

Ear ModeForehead/Object mode

Automatically switched between forehead & ear mode.

Page 3: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

USE INSTRUCTIONS

Measuring foreheadtemperature

With the probe cover attached, point the thermometer at the center of the forehead.

Move the thermometer towards the forehead until the probe cover 1-3 cm away from the skin.

Press and release the Measure button. The temperature will be displayed on the screen instantly.

Make sure that the forehead is free of hair and perspiration.

1

2

3

Measuring temperature via eardrum

Gently remove the probe cover to reveal the ear probe.

Insert the ear probe into the ear canal.

Press and release the Measure button. The temperature will be displayed on the screen instantly.

Make sure that the ear canal is straight so that the sensor is in line with the eardrum.

1

2

3

Page 4: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

Make sure that the ear canal is straight so that the sensor is in line with the eardrum.

FEATURES

Good safety

Passive infrared receiving technology

Easy operation

Ergonomic design

One button measurement

Quick measurement

1-second measurement

High accuracy

Advanced infrared temperature sensor, with high sensitivity

High accuracy with automatic temperature calibration

Diverse functions

20 readings recall

Fever alert

Switching between ºC and ºF

Automatic power-off, power saving

Extensive application scope

Forehead temperature measurement applicable to all age groups

Ear temperature measurement applicable to children older

than three months, adults, and the elderly

Child mode

This mode is recommended for people under 12 years of age

1

2

3

4

5

6

7

Page 5: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

DISPLAY DESCRIPTION1 Object temperature mode

2 Forehead temperature mode

3 Child mode

4 Ear temperature mode

5 Mute/un-mute

6 Temperature unit (ºF/ºC)

7 Low battery

8 Memory recall

9 Temperature value

Screen Display Operating Instructions

Measuring Ear temperature (Adult / Child)

Ear temperaturefor adult

Take off the probe cover, press andrelease the Power button for 1second to power on thethermometer. The symbol “ ” isdisplayed on the screen.

Switch to the adult or childmeasurement mode by pressing theMode button according to yourmeasurement needs.

Insert the temperature probe into aproper position in the ear canal.Press the Measure button to start ameasurement.

See the table in the“Sounds andbacklight colorinstructions”section.

Sound andBackground Light

Ear temperaturefor child

Page 6: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

SCREEN DISPLAY OPERATING INSTRUCTIONS

Measuring Forehead temperature (Adult / Child)

Forehead temperature

for adult

SOUND ANDBACKLIGHT

COLOR

Forehead temperature

for child

Put the cover on the probe, pressand release the Power button for 1second to power on thethermometer The “Head” symbol

is displayed on the screen.

Switch to the adult or childmeasurement mode by pressing theMode button according to yourmeasurement needs.

Point the thermometer to the centerof the forehead.about”1-3cm ”away from the skin surface. Pressand release the Measure button.The temperature will be displayedon the screen.

See the table in“Sounds andbacklight colorinstructions”section.

DISPLAY DESCRIPTION

Page 7: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

Put the cover on the probe, switchto the object measurement mode bypressing the Mode button.Thethermometer enters the Objectmode. The “House” symbol isdisplayed on the screen.

Point the thermometer to the centerof the object. Press and release theMeasure button. The temperaturewill be displayed on the screen.

See the table in the“Sounds andbacklight colorinstructions”section.

In Ear mode, a temperature readingof more than 42.0ºC (107.6ºF)

In Forehead mode, a temperaturereading of more than 42.2ºC(108.0ºF)

In Object mode, a temperaturereading of more than 100ºC(212.0ºF)

A long beeps,thebacklight is red.

For referenceonly

In Ear mode, a temperature readingof less than 35.0ºC (95.0ºF)In Forehead mode, a temperaturereading of less than 35.0ºC (95.0ºF)In Object mode, a temperaturereading of less than 0ºC (32.0ºF)

A long beeps, thebacklight is red.

SCREEN DISPLAY OPERATING INSTRUCTIONS

SOUND ANDBACKLIGHT

COLOR

Out of the Measuring Range Display

Recall 20 memories

For referenceonly

Page 8: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

In a power-on state, press theMemory button enter the memorymode.

When the Memory button isreleased, 01 will be shown,followed by the recorded reading.

Press the Memory button again forthe next recorded data. 02 will beshown, followed by the recordedreading.

A maximum of 20 temperaturereadings can be recalled.When the maximum number ofrecords is exceeded, the earliestmemory data will be overwritten.

Note:01 means the latest data.

Silent,thebacklight is

green.

SCREEN DISPLAY OPERATING INSTRUCTIONS

SOUND ANDBACKLIGHT

COLOR

No memory data / Clear memory data

Page 9: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

The display is as shown , whenthere is no more data checked whilerecalling memories. Remove 2 drybatteries and after 10 secondsre-install the power to clear allmemory data.

When the power isturned back on,there are a longbeep and a greenbacklight, whichthen turns into red.

In the power-on state, press andhold the sound switch button forabout 2 seconds to switch the soundon or off. When the sound is turnedon, it will beep once and the mutesymbol will be displayed when thesound is off.

The symbol shows up in Mutemode and disappears in Un-mutemode.

When the sound isturned on, itsounds a longbeep and thebacklight isgreen.

SCREEN DISPLAY OPERATING INSTRUCTIONS

SOUND ANDBACKLIGHT

COLOR

Switching between mute and un-mute

Switching between object temperature and body temperature

Page 10: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

When putting on the probe cover,press the Mode button to switchbetween object and foreheadmodes. Ear mode (adult/child) willbe activated by removing the probecover.

Silent, thebacklight is green.

In a power-on state,you can changeunits, by switching the ºF/ºCbutton.

Silent

SCREEN DISPLAY OPERATING INSTRUCTIONS

SOUND ANDBACKLIGHT

COLOR

Switching between ºF/ºC

Page 11: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

The ambient temperature is higherthan 40.0ºC (104.0ºF) or lower than10.0ºC (50.0ºF).

A long beeps,thebacklight is red.

An error occurs when data is beingread from or written to the memory,or the temperature correction is notcomplete.

A long beeps,thebacklight is red.

When the battery voltage is lowerthan 2.4V ± 0.1V, the low batterysymbol will appear on the display.Please replace the batteries.

Silent

SCREEN DISPLAY OPERATING INSTRUCTIONS

SOUND ANDBACKLIGHT

COLOR

Error Information & Low Battery

Page 12: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

24

The temperaturereading is higherthan the typicalbody temperaturerange.

The temperature probeis damaged.

Contact themanufacturer.

Product Name Infrared ThermometerProduct Model JPD-FR412Power SupplyMode

Internal power supply

Operating Voltage DC 3VBattery Model AAA x 2Operating Mode Continuous operatingDisplay Segment LCDMeasure time About 1 secondLatency Time About 3 seconds

Measuring RangeForehead mode:35.0°C–42.2°C (95.0°F–108.0°F)Ear mode:35.0°C–42.0°C (95.0°F–107.6°F)Object mode:0.0°C–100.0°C (32.0°F–212.0°F)

Accuracy(Laboratory)

Forehead mode: ±0.2°C (±0.4°F)Ear mode: ±0.2°C (±0.4°F)Object mode: ±1.0� /±2.0�

Resolution 0.1°C (0.1°F)Memory 20 temperature readings

Low-battery AlertThe low-battery symbol is displayed if the powervoltage is lower than 2.4 V±0.1V

AutomaticPower-off

The thermometer automatically powers off if it is notused in 10±1 seconds.

SPECIFICATIONS

24

The temperaturereading is higherthan the typicalbody temperaturerange.

The temperature probeis damaged.

Contact themanufacturer.

Product Name Infrared ThermometerProduct Model JPD-FR412Power SupplyMode

Internal power supply

Operating Voltage DC 3VBattery Model AAA x 2Operating Mode Continuous operatingDisplay Segment LCDMeasure time About 1 secondLatency Time About 3 seconds

Measuring RangeForehead mode:35.0°C–42.2°C (95.0°F–108.0°F)Ear mode:35.0°C–42.0°C (95.0°F–107.6°F)Object mode:0.0°C–100.0°C (32.0°F–212.0°F)

Accuracy(Laboratory)

Forehead mode: ±0.2°C (±0.4°F)Ear mode: ±0.2°C (±0.4°F)Object mode: ±1.0 /±2.0°C °F

Resolution 0.1°C (0.1°F)Memory 20 temperature readings

Low-battery AlertThe low-battery symbol is displayed if the powervoltage is lower than 2.4 V±0.1V

AutomaticPower-off

The thermometer automatically powers off if it is notused in 10±1 seconds.

Page 13: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

SPECIFICATIONS

Outer dimensions(mm)

155.9*40.2*49.2mm

Weight (g) Thermometer (with batteries): 90g

OperatingEnvironment

Temperature: 10°C~ 40°C (50°F–104°F)Humidity: 15%–95% RH, non-condensingAtmospheric pressure: 86–106 kPa

The infrared thermometer has been tested and conforms to the standard

ASTM E1965-98. ASTM laboratory accuracy requirements in the display

range of 96.8°F to102.2°F (36°C-39°C) for ear canal IR thermometers is

±0.4°F (±0.2°C). Note that for mercury-in-glass and electronic

thermometers, the requirement per ASTM Standards E667-86 and

E1112-86 is ±0.2°F (±0.1°C).

Security Class

Type of protection against electric shock: internally powered equipment.

Degree of protection against electric shock: Type BF applied part.

■ Degree of protection against ingress of water:IP22

■ Safety degree of using in flammable anesthetic gas blending with air,

oxygen or nitrous oxide: Non-AP/APG

■ No application parts of the thermometer prevents defibrillation charge

effect.

■ No application parts of the thermometer output signal.

■ The thermometer is impermanent installed device.

Storage and Transportation

Page 14: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

NOTICE

Please use the thermometer indoor or in an environment where there is no strong air draft.

Make sure that both user and thermometer have stayed in steady-state room condition for at least 30 minutes.

Please wait at least 10 minutes before using the thermome-ter, If the thermometer is transferred from an environment.

Operating environment

Keep sensor clean

Check and clean the lens regularly. If it’s not clear, please clean it with a cotton swab with alcohol, wait 5-10 mins, you can use thermometer after alcohol evaporated completely.

Page 15: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C

Forehead mode: make sure there isn’t any sweat, water or condensation on it.

Ear mode: please remove earwax, keep the ear canal clean.

Keep forehead/ear clean

Don’t move during measurement.

Don’t hold the thermometer for long time as it’s highly sensitive to heat.

Do not repeat use with no pause. If taking multiple readings, it is advised to wait at least 10 seconds between readings.

NOTICE

Page 16: USER MANUAL EAR AND FOREHEAD THERMOMETER€¦ · USER MANUAL EAR AND FOREHEAD THERMOMETER. PRODUCT STRUCTURE (1) Probe cover (2) Probe (3) LCD display (4) Power/ Measure (5) °F/°C