101
LUNA2000-(5-30)-S0 User Manual Issue 02 Date 2020-11-20 HUAWEI TECHNOLOGIES CO., LTD.

User Manual - Amazon Web Services

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: User Manual - Amazon Web Services

LUNA2000-(5-30)-S0

User Manual

Issue 02

Date 2020-11-20

HUAWEI TECHNOLOGIES CO., LTD.

Page 2: User Manual - Amazon Web Services

Copyright © Huawei Technologies Co., Ltd. 2020. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without priorwritten consent of Huawei Technologies Co., Ltd. Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respectiveholders. NoticeThe purchased products, services and features are stipulated by the contract made between Huawei andthe customer. All or part of the products, services and features described in this document may not bewithin the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,information, and recommendations in this document are provided "AS IS" without warranties, guaranteesor representations of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in thepreparation of this document to ensure accuracy of the contents, but all statements, information, andrecommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.Address: Huawei Industrial Base

Bantian, LonggangShenzhen 518129People's Republic of China

Website: https://e.huawei.com

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. i

Page 3: User Manual - Amazon Web Services

About This Document

PurposeThis document describes the LUNA2000 battery in terms of its overview,application scenarios, installation and commissioning, system maintenance, andtechnical specifications. The LUNA2000 battery consists of a LUNA2000-5KW-C0power control module and LUNA2000-5-E0 battery expansion modules.

Intended AudienceThis document is intended for:

● Sales engineers

● System engineers

● Technical support engineers

Symbol ConventionsThe symbols that may be found in this document are defined as follows.

Symbol Description

Indicates a hazard with a high level of risk which, if notavoided, will result in death or serious injury.

Indicates a hazard with a medium level of risk which, if notavoided, could result in death or serious injury.

Indicates a hazard with a low level of risk which, if notavoided, could result in minor or moderate injury.

Indicates warning information about device or environmentsecurity which, if not avoided, could result in equipmentdamage, data loss, performance deterioration, orunanticipated results.NOTICE is used to address practices not related to personalinjury.

LUNA2000-(5-30)-S0User Manual About This Document

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. ii

Page 4: User Manual - Amazon Web Services

Symbol Description

Supplements the important information in the main text.NOTE is used to address information not related to personalinjury, equipment damage, and environment deterioration.

Change HistoryChanges between document issues are cumulative. The latest document issuecontains all the changes made in earlier issues.

Issue 02 (2020-11-20)● Updated 2.3 Label Description.● Updated 3.1 Grid-tied ESS.● Updated 4.3 Determining the Installation Position.● Updated 7.4 Battery Storage and Recharge.● Updated 8.1 LUNA2000-5KW-C0.● Updated 8.2 LUNA2000-5-E0.

Issue 01 (2020-10-20)This issue is the first official release.

LUNA2000-(5-30)-S0User Manual About This Document

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. iii

Page 5: User Manual - Amazon Web Services

Contents

About This Document................................................................................................................ ii

1 Safety Precautions...................................................................................................................11.1 General Safety.......................................................................................................................................................................... 11.2 Personnel Requirements....................................................................................................................................................... 31.3 Electrical Safety........................................................................................................................................................................41.4 Installation Environment Requirements.......................................................................................................................... 51.5 Transportation Requirements.............................................................................................................................................. 61.6 Mechanical Safety................................................................................................................................................................... 71.7 Commissioning......................................................................................................................................................................... 81.8 Maintenance and Replacement..........................................................................................................................................8

2 Product Introduction............................................................................................................ 102.1 Overview.................................................................................................................................................................................. 102.2 Appearance............................................................................................................................................................................. 132.3 Label Description.................................................................................................................................................................. 152.4 Features.................................................................................................................................................................................... 172.5 Working Mode....................................................................................................................................................................... 18

3 Application Scenarios and Settings.................................................................................. 203.1 Grid-tied ESS...........................................................................................................................................................................203.1.1 Grid-tied ESS Networking...............................................................................................................................................203.1.2 Setting the Grid-tied ESS Mode....................................................................................................................................243.2 Grid-tied and Off-grid ESS.................................................................................................................................................303.2.1 Grid-tied and Off-grid ESS Networking.....................................................................................................................303.2.2 Setting the Grid-tied and Off-grid ESS Mode..........................................................................................................343.3 Pure Off-grid ESS.................................................................................................................................................................. 353.3.1 Pure Off-grid ESS Networking...................................................................................................................................... 353.3.2 Setting the Pure Off-grid ESS Mode........................................................................................................................... 36

4 System Installation............................................................................................................... 384.1 Checking Before the Installation..................................................................................................................................... 384.2 Preparing Tools and Instruments.................................................................................................................................... 384.3 Determining the Installation Position............................................................................................................................404.4 Equipment Installation........................................................................................................................................................ 414.4.1 Floor-Mounted Installation............................................................................................................................................ 41

LUNA2000-(5-30)-S0User Manual Contents

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. iv

Page 6: User Manual - Amazon Web Services

4.4.2 Wall-Mounted Installation............................................................................................................................................. 46

5 Electrical Connection............................................................................................................505.1 Preparing Cables................................................................................................................................................................... 515.2 Internal Electrical Connections of the Battery............................................................................................................ 525.2.1 Installing an Internal Ground Cable............................................................................................................................525.2.2 Installing Internal DC Terminals................................................................................................................................... 535.2.3 Connecting Internal Signal Cables...............................................................................................................................545.3 External Electrical Connections of the Battery........................................................................................................... 555.3.1 Installing a PE Cable.........................................................................................................................................................565.3.2 Installing DC Input Power Cables................................................................................................................................ 585.3.3 Installing a Signal Cable................................................................................................................................................. 595.4 (Optional) Cascading Batteries........................................................................................................................................ 625.5 Installing the Cover.............................................................................................................................................................. 64

6 System Commissioning........................................................................................................ 666.1 Verification Before Power-On........................................................................................................................................... 666.2 System Power-On................................................................................................................................................................. 676.3 Battery Commissioning....................................................................................................................................................... 686.3.1 Battery Deployment......................................................................................................................................................... 686.3.2 Battery Control................................................................................................................................................................... 696.3.3 Querying the Battery Status.......................................................................................................................................... 726.3.4 Battery Maintenance and Upgrade............................................................................................................................. 72

7 System Maintenance............................................................................................................ 757.1 System Power-Off.................................................................................................................................................................757.2 Routine Maintenance.......................................................................................................................................................... 757.3 Troubleshooting..................................................................................................................................................................... 767.4 Battery Storage and Recharge..........................................................................................................................................86

8 Technical Specifications....................................................................................................... 918.1 LUNA2000-5KW-C0.............................................................................................................................................................. 918.2 LUNA2000-5-E0..................................................................................................................................................................... 92

9 FAQ........................................................................................................................................... 939.1 How Do I Replace a Fuse?................................................................................................................................................. 93

A Acronyms and Abbreviations............................................................................................. 95

LUNA2000-(5-30)-S0User Manual Contents

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. v

Page 7: User Manual - Amazon Web Services

1 Safety Precautions

1.1 General Safety

DeclarationBefore installing, operating, and maintaining the equipment, read this documentand observe all the safety instructions on the equipment and in this document.

The "NOTICE", "WARNING", and "DANGER" statements in this document do notcover all the safety instructions. They are only supplements to the safetyinstructions. Huawei will not be liable for any consequence caused by the violationof general safety requirements or design, production, and usage safety standards.

Ensure that the equipment is used in environments that meet its designspecifications. Otherwise, the equipment may become faulty, and the resultingmalfunction, component damage, personal injuries, or property damage are notcovered under the warranty.

Follow local laws and regulations when installing, operating, or maintaining theequipment. The safety instructions in this document are only supplements to locallaws and regulations.

Huawei will not be liable for any consequences of the following circumstances:

● Operation beyond the conditions specified in this document● Installation or use in environments which are not specified in relevant

international or national standards● Unauthorized modifications to the product or software code or removal of the

product● Failure to follow the operation instructions and safety precautions on the

product and in this document● Equipment damage due to force majeure, such as earthquakes, fire, and

storms● Damage caused during transportation by the customer● Damage caused by storage conditions that do not meet the requirements

specified in related documents

LUNA2000-(5-30)-S0User Manual 1 Safety Precautions

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 1

Page 8: User Manual - Amazon Web Services

General Requirements

D ANGER

Do not work with power on during installation.

● Do not install, use, or operate outdoor equipment and cables (including butnot limited to moving equipment, operating equipment and cables, insertingconnectors to or removing connectors from signal ports connected to outdoorfacilities, working at heights, and performing outdoor installation) in harshweather conditions such as lightning, rain, snow, and level 6 or stronger wind.

● After installing the equipment, remove idle packing materials such as cartons,foam, plastics, and cable ties from the equipment area.

● In the case of a fire, immediately leave the building or the equipment area,and turn on the fire alarm bell or make an emergency call. Do not enter thebuilding on fire in any case.

● Do not scrawl, damage, or block any warning label on the equipment.● Tighten screws using tools when installing the equipment.● Understand the components and functioning of a grid-tied PV power system

and relevant local standards.● Repaint any paint scratches caused during equipment transportation or

installation in a timely manner. Equipment with scratches cannot be exposedto an outdoor environment for a long period of time.

● Do not open the host panel of the equipment.● Without prior consent from the manufacturer, do not alter the internal

structure or installation procedure of the equipment.● Ensure that battery terminal components are not affected during

transportation. Do not hoist or move batteries by using battery terminal bolts.

Personal Safety● Wear proper personal protective equipment (PPE) during operation. If there is

a probability of personal injury or equipment damage, immediately stop theoperations, report the case to the supervisor, and take feasible protectivemeasures.

● Use tools correctly to avoid hurting people or damaging the equipment.● Do not touch the energized equipment, as the enclosure is hot.● To ensure personal safety and normal use of the equipment, the equipment

must be reliably grounded before use.● When a battery is faulty, the temperature may exceed the burn threshold of

the touchable surface. Therefore, avoid touching the battery.● Do not disassemble or damage the battery. The released electrolyte is harmful

to your skin and eyes. Avoid contact with the electrolyte.● Do not place irrelevant objects on the top of the equipment or insert them

into any position of the equipment.● Do not place inflammables around the equipment.

LUNA2000-(5-30)-S0User Manual 1 Safety Precautions

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 2

Page 9: User Manual - Amazon Web Services

● To prevent explosions and body injury, do not place batteries in a fire.● Do not place the battery module in water or other liquids.● Do not short-circuit wiring terminals of batteries. Short circuits can cause a

fire.● Batteries may cause electric shocks and high short-circuit currents. When

using the battery, pay attention to the following points:(a) Remove any metal objects from yourself, such as watches and rings.(b) Use tools with insulated handles.(c) Wear rubber gloves and boots.(d) Do not place tools or metal parts on top of batteries.(e) Before connecting or disconnecting battery terminals, disconnect thecharging power supply.(f) Check whether batteries are accidentally grounded. If it is accidentallygrounded, remove the power supply from the ground. Touching any part of agrounded battery can cause an electric shock. If these grounding points areremoved during installation and maintenance, the possibility of electric shockscan be reduced.

● Do not use water to clean electrical components inside or outside of acabinet.

● Do not stand on, lean on, or sit on the top of the equipment.● Do not damage the modules of the equipment.

1.2 Personnel Requirements● Personnel who plan to install or maintain Huawei equipment must receive

thorough training, understand all necessary safety precautions, and be able tocorrectly perform all operations.

● Only qualified professionals or trained personnel are allowed to install,operate, and maintain the equipment.

● Only qualified professionals are allowed to remove safety facilities and inspectthe equipment.

● Personnel who will operate the equipment, including operators, trainedpersonnel, and professionals, should possess the local national requiredqualifications in special operations such as high-voltage operations, workingat heights, and operations of special equipment.

● Only professionals or authorized personnel are allowed to replace theequipment or components (including software).

NO TE

● Professionals: personnel who are trained or experienced in equipment operationsand are clear of the sources and degree of various potential hazards in equipmentinstallation, operation, and maintenance

● Trained personnel: personnel who are technically trained, have required experience,are aware of possible hazards on themselves in certain operations, and are able totake protective measures to minimize the hazards on themselves and other people

● Operators: operation personnel who may come in contact with the equipment,except trained personnel and professionals

LUNA2000-(5-30)-S0User Manual 1 Safety Precautions

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 3

Page 10: User Manual - Amazon Web Services

1.3 Electrical Safety

Grounding Requirements● For the equipment that needs to be grounded, install the protective earthing

(PE) cable first when installing the equipment and remove the PE cable lastwhen removing the equipment.

● Do not damage the ground conductor.

● Do not operate the equipment in the absence of a properly installed groundconductor.

● Ensure that the equipment is connected permanently to the protectiveground. Before operating the equipment, check the electrical connection toensure that it is securely grounded.

General Requirements

D ANGER

Before connecting cables, ensure that the equipment is intact. Otherwise, electricshocks or fire may occur.

● Ensure that all electrical connections comply with local electrical standards.

● Obtain approval from the local electric utility company before using theequipment in grid-tied mode.

● Ensure that the cables you prepared meet local regulations.

● Use dedicated insulated tools when performing high-voltage operations.

DC Operation

D ANGER

Do not connect or disconnect power cables with power-on. Transient contactbetween the core of the power cable and the conductor will generate electric arcsor sparks, which may cause fire or personal injury.

● Before connecting cables, switch off the disconnector on the upstreamequipment to cut off the power supply if people may contact energizedcomponents.

● Before connecting a power cable, check that the label on the power cable iscorrect.

● If the equipment has multiple inputs, disconnect all the inputs beforeoperating the equipment.

LUNA2000-(5-30)-S0User Manual 1 Safety Precautions

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 4

Page 11: User Manual - Amazon Web Services

Cabling Requirements● When routing cables, ensure that a distance of at least 30 mm exists between

the cables and heat-generating components or areas. This prevents damageto the insulation layer of the cables.

● Bind cables of the same type together. When routing cables of different types,ensure that they are at least 30 mm away from each other.

● Ensure that the cables used in a grid-tied PV power system are properlyconnected and insulated and meet specifications.

1.4 Installation Environment Requirements● Install the battery in a dry and well-ventilated environment to ensure good

heat dissipation.● You are advised to install the battery in a sheltered place or install an awning

over it.● Install the battery in a clean environment that is free from sources of strong

infrared radiation, organic solvents, and corrosive gases. Avoid exposing thebattery to direct sunlight or water.

● The installation position must be far away from fire sources.● Children are not allowed to enter the installation position.● The installation position must be far away from water sources such as taps,

sewer pipes, and sprinklers to prevent water seepage.● The battery must be placed on a solid and flat supporting surface.● Do not place any flammable or explosive materials around the battery.● To prevent fire due to high temperature, ensure that the ventilation vents or

heat dissipation system are not blocked when the battery is running.● Do not expose the battery to flammable or explosive gas or smoke. Do not

perform any operation on the battery in such environments.● The battery system site must be equipped with qualified fire extinguishing

facilities, such as fire extinguishing sands and powder fire extinguishers.

LUNA2000-(5-30)-S0User Manual 1 Safety Precautions

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 5

Page 12: User Manual - Amazon Web Services

Figure 1-1 Installation environment

CA UTION

The operation and service life of the battery depend on the operatingtemperature. Install the battery at a temperature equal to the ambienttemperature or in a better environment. The recommended operatingtemperature ranges from 15°C to 30°C.

1.5 Transportation RequirementsThe product passes the certifications of the UN38.3 (UN38.3: Section 38.3 of theSixth Revised Edition of the Recommendations on the Transport of DangerousGoods, Manual of Tests and Criteria) and SN/T 0370.2-2009 (Part 2: PerformanceTest of the Rules for the Inspection of Packaging for Exporting Dangerous Goods).This product belongs to class 9 dangerous goods.

The product can be delivered to the site directly and transported by land andwater. The packing case must be secured for transportation, compliant withrelated China standards, and printed with marks such as anti-collision andmoisture prevention. Affected by external environment factors, such astemperature, transportation, and storage, the product specifications at the deliverydate prevail.

Protect the packing case with the product from the following situations:

LUNA2000-(5-30)-S0User Manual 1 Safety Precautions

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 6

Page 13: User Manual - Amazon Web Services

● Being dampened by rains, snows, or falling into water● Falling or mechanical impact● Being upside-down or tilted

1.6 Mechanical Safety

Using Ladders● Use wooden or fiberglass ladders when you need to perform live working at

heights.● When a step ladder is used, ensure that the pull ropes are secured and the

ladder is held firm.● Before using a ladder, check that it is intact and confirm its load bearing

capacity. Do not overload it.● Ensure that the wider end of the ladder is at the bottom, or protective

measures have been taken at the bottom to prevent the ladder from sliding.● Ensure that the ladder is securely positioned. The recommended angle for a

ladder against the floor is 75 degrees, as shown in the following figure. Anangle rule can be used to measure the angle.

● When climbing a ladder, take the following precautions to reduce risks andensure safety:– Keep your body steady.– Do not climb higher than the fourth rung of the ladder from the top.– Ensure that your body's center of gravity does not shift outside the legs

of the ladder.

Drilling HolesWhen drilling holes into a wall or floor, observe the following safety precautions:

● Wear goggles and protective gloves when drilling holes.● When drilling holes, protect the equipment from shavings. After drilling, clean

up any shavings that have accumulated inside or outside the equipment.

LUNA2000-(5-30)-S0User Manual 1 Safety Precautions

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 7

Page 14: User Manual - Amazon Web Services

Moving Heavy Objects● Be cautious to avoid injury when moving heavy objects.

● When moving the equipment by hand, wear protective gloves to preventinjuries.

1.7 CommissioningWhen the equipment is powered on for the first time, ensure that professionalpersonnel set parameters correctly. Incorrect settings may result in inconsistencywith local certification and affect the normal operation of the equipment.

1.8 Maintenance and Replacement

D ANGER

High voltage generated by the equipment during operation may cause an electricshock, which could result in death, serious injury, or serious property damage.Prior to maintenance, power off the equipment and strictly comply with the safetyprecautions in this document and relevant documents.

● Maintain the equipment with sufficient knowledge of this document andusing proper tools and testing equipment.

● Before maintaining the equipment, power it off and follow the instructions onthe delayed discharge label to ensure that the equipment is powered off.

● Place temporary warning signs or erect fences to prevent unauthorized accessto the maintenance site.

● If the equipment is faulty, contact your dealer.● The equipment can be powered on only after all faults are rectified. Failing to

do so may escalate faults or damage the equipment.● Do not open the cover without authorization. Otherwise, electric shocks may

occur, and the resulting faults are beyond warranty scope.● Installation personnel, maintenance personnel, and technical support

personnel must be trained to operate and maintain the equipment safely andcorrectly, take comprehensive precautionary measures, and be equipped withprotective instruments.

● Before moving or reconnecting the equipment, disconnect the mains andbatteries and wait for five minutes until the equipment powers off. Beforemaintaining the equipment, check that no dangerous voltages remain in theDC bus or components to be maintained by using a multimeter.

LUNA2000-(5-30)-S0User Manual 1 Safety Precautions

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 8

Page 15: User Manual - Amazon Web Services

● Battery maintenance should be carried out or supervised by personnel whoare familiar with batteries and the precautions required.

● When replacing batteries, replace them with batteries or battery strings of thesame type.

● Take out all tools and parts from the equipment after maintenance iscomplete.

● If the equipment is not used for a long time, store and recharge batteriesaccording to this document.

LUNA2000-(5-30)-S0User Manual 1 Safety Precautions

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 9

Page 16: User Manual - Amazon Web Services

2 Product Introduction

2.1 Overview

FunctionThe LUNA2000 battery consists of a power control module and battery expansionmodules. It can store and release electric energy based on the requirements of theinverter management system. The input and output ports of the LUNA2000battery are high-voltage direct current (HVDC) ports.

● Battery charge: The power control module connects to the battery terminals(BAT+ and BAT–) of the inverter. Under the control of the inverter, the powercontrol module charges the batteries and stores excessive PV energy inbatteries.

● Battery discharge: When the PV energy is insufficient to supply power to theloads, the system controls the batteries to supply power to the loads. Thebattery energy is output to the loads through the inverter.

Model● Model of the power control module in the LUNA2000 battery:

LUNA2000-5KW-C0

Figure 2-1 Model number

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 10

Page 17: User Manual - Amazon Web Services

Table 2-1 Model description

No. Meaning Value

1 Product LUNA2000: LUNA2000 battery

2 Power level 5KW: The power level is 5 kW.

3 Design code C0: product series of the power controlmodule

● Model of battery expansion modules in the LUNA2000 battery: LUNA2000-5-E0

Figure 2-2 Model number

Table 2-2 Model description

No. Meaning Value

1 Product LUNA2000: residential battery

2 Energy level 5: The energy level is 5 kWh.

3 Design code E0: battery pack module

● The model of the LUNA2000 battery is LUNA2000-5-S0.

Figure 2-3 Model number

Table 2-3 Model description

No. Meaning Value

1 Product LUNA2000: residential battery

2 Energy level 5: The capacity level is 5 kWh. This productsupports 5 kWh to 30 kWh.

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 11

Page 18: User Manual - Amazon Web Services

No. Meaning Value

3 Design code S0: battery

Battery Capacity DescriptionThe battery supports power and capacity expansion. Two power control modulescan be connected in parallel. One power control module supports a maximum ofthree battery expansion modules.

Figure 2-4 Battery capacity description

Networking ApplicationThe LUNA2000 battery is applicable to the grid-tied systems of residential rooftopPV plants. Typically, a grid-tied system consists of PV strings, LUNA2000 batteries,an inverter, an AC switch, and a power distribution box (PDB).

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 12

Page 19: User Manual - Amazon Web Services

Figure 2-5 Networking (dashed boxes indicate optional components)

(A) PV string (B) DC switch (C) SUN2000

(D) AC switch (E) ACDU (F) Smart Power Sensor

(G) Power grid (H) LUNA2000 (I) 4G Smart Dongle

(J) WLAN-FE Smart Dongle (K) Router (L) FusionSolar managementsystem

(M) FusionSolar app (N) Load

NO TE

● indicates a power cable, indicates a signal cable, indicateswireless communication.

● The input and output ports of the LUNA2000 battery are connected to the battery portsof the inverter.

● The following communication modes are supported by the LUNA2000 battery:● Connect the LUNA2000 battery to the inverter over the RS485 port and Enable port

to implement communication and control between the inverter and the LUNA2000battery.

● Use the mobile phone App to directly connect to the inverter or connect to theinverter in the same LAN to manage and maintain the LUNA2000 battery.

● Connect the inverter to the public network through the Smart Dongle to manageand maintain the LUNA2000 battery through the management system.

2.2 Appearance

BatteryThis topic describes the battery appearance.

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 13

Page 20: User Manual - Amazon Web Services

Figure 2-6 Battery appearance

(1) LED-indicator (2) DC switch (3) Power controlmodule

(4) Battery expansionmodules

(5) Installation base () Black start switch

(7) Heat sink

Power Control ModuleThe power of the power control module is 5 kW.

Figure 2-7 Power control module

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 14

Page 21: User Manual - Amazon Web Services

(1) Power controlmodule

(2) Black start switch (3) Battery terminals (BAT+/BAT–)

(4) COM port (COM) (5) Battery cascadingterminals (B+/B–)

(6) DC switch (DC SWITCH)

(7) COM port (COM) (8) Fuse (9) Ground point

(10) Batteryterminals (BAT+/BAT–)

Battery Expansion ModuleThe standard capacity of a battery expansion module is 5 kWh.

Figure 2-8 Battery expansion module

(1) Battery expansionmodule

(2) Boss for alignment (3) Battery cascadingterminals (B+/B–)

(4) Battery cascadingterminals (B+/B–)

(5) COM port (COM) (6) Ground point

(7) Heat sink (8) Ground point

2.3 Label Description

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 15

Page 22: User Manual - Amazon Web Services

Enclosure Labels

Table 2-4 Enclosure label description

Icon Name Meaning

Burn warning Do not touch theproduct, as the shell ishot when it is running.

Delayed discharge ● High voltage existsafter the battery ispowered off. Ittakes 5 minutes forthe battery todischarge to thesafe voltage.

Operator ● High voltage existsafter the battery ispowered on. Onlyqualified andtrained electricaltechnicians areallowed to installand operate thebattery.

● Ground the batterybefore powering iton.

Refer todocumentation

Reminds operators torefer to thedocumentationprovided with theequipment.

Grounding Indicates the positionfor connecting the PEcable.

NO TE

The labels are for reference only.

NameplateNameplate of a power control module

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 16

Page 23: User Manual - Amazon Web Services

Figure 2-9 Nameplate (power control module)

Nameplate of a battery expansion module

Figure 2-10 Nameplate (battery expansion module)

2.4 Features

Multi-Scenario and Multi-Working Mode● Supports multiple working modes such as grid-tied, grid-tied and off-grid,

pure off-grid multi-scenario, self-consumption, time-of-use, and full fed to thegrid modes.

● Allows users to query the total discharge capacity in the product life cycle inreal time.

Intelligent and Simple Operation

Works with the inverter, supports plug-and-play, and integrates the mobile phoneapp and management system.

Easy Installation and Replacement● Standard battery DC terminals are used for system connection.● Modular design is adopted for batteries.● The installation or replacement can be performed by two persons.

Flexible Scalability

The battery supports power expansion, battery capacity expansion, and hybrid useof old and new batteries.

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 17

Page 24: User Manual - Amazon Web Services

Intelligent O&M● The factory defaults meet the requirements of target markets and the battery

can be started by pressing only one button and supports black startup.● The LED indicator shows the status. You can also use the mobile phone app to

perform local and remote operations.● The cloud data management system is used to manage the battery anytime

and anywhere.

Low Investment● Only common installation tools are required.● The battery features high efficiency and power density, which saves

installation space.● The battery features easy O&M.

2.5 Working ModeThe LUNA2000 converts HVDC generated by PV strings into low-voltage directcurrent (LVDC) through DC-to-DC conversion and stores the power in batteries. Itcan also convert LVDC into HVDC and then into AC power through the inverter.

Working ModeThe LUNA2000 battery can work in hibernation, standby, or operating mode.

Table 2-5 Working mode

WorkingMode

Description

Hibernationmode

The internal auxiliary power source and DC-DC converter of thebattery do not work.

Standbymode

The auxiliary power source inside the battery works, and theDC-DC converter does not work.

Operatingmode

The internal auxiliary power source of the battery works, andthe DC-DC converter charges or discharges.

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 18

Page 25: User Manual - Amazon Web Services

Figure 2-11 Switchover among working modes

LUNA2000-(5-30)-S0User Manual 2 Product Introduction

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 19

Page 26: User Manual - Amazon Web Services

3 Application Scenarios and Settings

The LUNA2000 battery is mainly used in grid-tied systems of residential rooftopPV plants and small-scale PV plants in industrial and commercial scenarios. Thesystem can be classified into the following three types based on applicationscenarios:

● Grid-tied energy storage system (ESS)● Grid-tied and off-grid ESS● Off-grid ESS

Multiple working modes can be set, such as maximum self-consumption, time-of-use, and fully fed to the grid.

3.1 Grid-tied ESS

3.1.1 Grid-tied ESS Networking

Networking 1: Inverter + BatteriesThe grid-tied ESS consists of the PV strings, LUNA2000 batteries, inverter, ACswitch, load, power distribution unit (PDU), Smart Power Sensor,and grid.

The SUN2000-(2KTL–6KTL)-L1 or SUN2000-(3KTL–10KTL)-M1 inverters aresupported.

The PV string converts solar energy into electric energy, which is then converted bythe inverter into power for loads and then fed to the power grid.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 20

Page 27: User Manual - Amazon Web Services

Figure 3-1 Grid-tied ESS networking diagram (dashed boxes indicate optionalcomponents)

Networking 2: Inverter (with Batteries) + Inverter (Without Batteries)The grid-tied ESS supports inverter cascading. A maximum of three inverters canbe cascaded. The batteries can be connected to one of the inverters formanagement. The batteries, power meter, and Smart Dongle need to beconnected to the same inverter.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 21

Page 28: User Manual - Amazon Web Services

Figure 3-2 Inverter (with batteries) + inverter (without batteries) (dashed boxesindicate optional components)

Table 3-1 Mapping relationship

Inverter SUN2000-1 SUN2000-2

Model SUN2000-(2KTL–6KTL)-L1/SUN2000-(3KTL–10KTL)-M1

SUN2000-(2KTL–6KTL)-L1/SUN2000-(3KTL–10KTL)-M1

NO TE

When the grid charging function is enabled, the surplus power generated by the inverterwithout batteries can be used to charge the inverter connected to the batteries.

Networking 3: Inverter (with Batteries) + Inverter (with Batteries)When the capacity requirement is high, you can add inverters and batteries. Amaximum of three inverters can be cascaded. Each battery connects to theinverter through an independent RS485 port and is managed by the inverterconnected to it.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 22

Page 29: User Manual - Amazon Web Services

Figure 3-3 Inverter (with batteries) + inverter (with batteries) (dashed boxesindicate optional components)

Table 3-2 Mapping relationship

Inverter SUN2000-1 SUN2000-2

Model SUN2000-(2KTL–6KTL)-L1/SUN2000-(3KTL–10KTL)-M1

SUN2000-(2KTL–6KTL)-L1/SUN2000-(3KTL–10KTL)-M1

NO TE

The parameters of each battery need to be set separately. When the grid charging functionis enabled, the surplus power generated by one inverter can be used to charge the otherinverter.

(A) PV string (B) DC switch (C) SUN2000

(D) AC switch (E) ACDU (F) Smart Power Sensor

(G) Power grid (H) LUNA2000 (I) 4G Smart Dongle

(J) WLAN-FE SmartDongle

(K) Router (L) FusionSolarmanagement system

(M) FusionSolar app (N) Load

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 23

Page 30: User Manual - Amazon Web Services

NO TE

indicates a power cable, indicates a signal cable, indicateswireless communication.

3.1.2 Setting the Grid-tied ESS ModeThe grid-tied ESS has three main working modes: self-consumption, time-of-use,and excess fed to the grid.

Self-Consumption● This mode applies to areas where the electricity price is high, or areas where

the FIT subsidy is low or unavailable.● Excess PV energy is stored in batteries. When PV power is insufficient or no PV

power is generated at night, batteries discharge to supply power to the loads,improving the self-consumption rate of the PV system and the self-sufficiencyrate of residential energy, and reducing electricity costs.

● In this mode, Maximum self-consumption is selected. By default, the chargecutoff capacity is 100% and the discharge cutoff capacity is 15% for HuaweiLUNA2000 batteries. For details about how to change the charge or dischargecutoff capacity, see 6.3 Battery Commissioning.

Figure 3-4 Battery control parameter setting

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 24

Page 31: User Manual - Amazon Web Services

Parameter Description Value Range

Working mode Set this parameter to the maximumself-consumption mode.

● Maximum self-consumption

● Time-of-use● Fully fed to grid

Maximum chargepower (kW)

Retain this parameter to the maximumcharge power. Additional configurationis not required.If only one batteryexpansion module is configured, themaximum charge power is 2.5 kW.

● [0, Maximum chargepower]

Maximum dischargepower (kW)

Retain this parameter to the maximumdischarge power. Additionalconfiguration is not required.If only onebattery expansion module is configured,the maximum charge power is 2.5 kW.

● [0, Maximum dischargepower]

End-of-charge capacity(%)

Set the charge cutoff capacity. 90%–100%

End-of-dischargecapacity (%)

Set the discharge cutoff capacity. 0%–20%

Example of Self-ConsumptionExamples of self-consumption:

(1) When the sunlight is sufficient, the PV module outputs 8 kW power, the loadsconsume 4 kW power, and the batteries charge 4 kW power.

(2) When the sunlight becomes weak, the PV module outputs 3 kW power, theloads consume 4 kW power, and the batteries discharge to supply 1 kW power tothe loads.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 25

Page 32: User Manual - Amazon Web Services

Figure 3-5 Example of Self-Consumption

Time-of-Use● This mode applies to scenarios where the price difference between peak and

off-peak hours is large.● In this mode, Time-of-use is selected. You can manually set the charge and

discharge time segments. For example, you can allow the grid to chargebatteries in low electricity price periods at night and discharge batteriesduring high electricity price periods, saving electricity fee. The charge fromgrid function must be enabled.

● A maximum of 14 time segments can be set. For details about how to setcharge and discharge parameters, see 6.3 Battery Commissioning.

● In some countries, the grid is not allowed to charge batteries. Therefore, thismode cannot be used.

● This mode requires at least one charging period and one dischargingperiod,the grid charges batteries during the charge time and supplies powerto loads during the discharge time. In other time segments that are not set,the batteries do not discharge, and the PV modules and grid supply power toloads. (In gird-tied and off-grid mode, if the grid is powered off, the batteriescan discharge at any time.)

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 26

Page 33: User Manual - Amazon Web Services

Figure 3-6 Time-of-use working mode

Table 3-3 Time-of-use mode setting

Parameter Description Value Range

Priority ofexcess PVenergy

● Charge: When the generated PV energyis greater than the loads, excess PVenergy is used to charge the batteries.After the maximum charge power isreached or the batteries are fullycharged, the excess PV energy is fed tothe grid.

● Fed to grid: When the generated PVenergy is greater than the loads, theexcess PV energy is preferentially fed tothe grid . When the inverter outputpower reaches the maximum value, theexcess energy is used to charge batteries.This setting is applicable to the scenariowhere the FIT is higher than theelectricity price. Batteries are used onlyfor backup power.

● Charge● Fed to grid

Allowed chargepower of grid(kW)

Indicates the maximum charge powerallowed by the grid. The value isdetermined by the local grid company. Ifthere is no requirement, the value is themaximum charge power of the ESS bydefault.

● [0,Maximumchargepowerallowed bythe grid]

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 27

Page 34: User Manual - Amazon Web Services

Figure 3-7 Battery control parameter setting

Table 3-4 Time-of-use parameter setting

Parameter Description Value Range

Charge fromgrid

If Charge from grid function is disabled bydefault, comply with the grid chargerequirements stipulated in local laws andregulations when this function is enabled.

● Disable● Enable

Grid chargecutoff SOC

Set the grid charge cutoff state of charge(SOC).

[20%, 100%]

Example of the time-of-use electricity price

Examples of the time-of-use electricity price:

Set power consumption peak hours (14:00 to 24:00) as the discharge time. Duringthis time, the batteries discharge. During other periods, such as 03:00-14:00 ,surplus PV energy can be used to charge the batteries, and the batteries do notdischarge. When the load power supply is insufficient, the grid supplies power tothe loads. For example, when the sunlight is insufficient, the PV module outputs 3

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 28

Page 35: User Manual - Amazon Web Services

kW power, the loads consume 4 kW power, and the grid supplies 1 kW power tothe loads.

Figure 3-8 time-of-use(set the discharge time)

Fully Fed to Grid● This mode applies to the grid-tied scenario where PV energy is fully fed to the

grid.● This mode maximizes the PV energy for grid connection. When the generated

PV energy in the daytime is greater than the maximum output capability ofthe inverter, the batteries are charged to store energy. When the PV energy isless than the maximum output capability of the inverter, batteries dischargeto maximize the output energy of the inverter to the grid.

● In this mode, Fully fed to grid is selected. For details, see 6.3 BatteryCommissioning.

Example of fully fed to grid:For example, when the PV modules generate 8 kW power, the SUN2000-5KTLinverter connects to the grid with the maximum output power of 5.5 kW, and thebatteries charge 2.5 kW power. When the sunlight becomes weak, the PV modulesgenerate 3 kW power, the batteries charge 2.5 kW power, and the inverterconnects to the grid with the maximum output power of 5.5 kW.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 29

Page 36: User Manual - Amazon Web Services

Figure 3-9 fully fed to grid

3.2 Grid-tied and Off-grid ESSThe grid-tied and off-grid ESS is mainly used to supply power to loads when thegrid is unstable and there are primary loads. The grid-tied and off-grid ESSswitches the inverter to the grid-tied or off-grid state through the Backup Box.When the grid fails, the inverter switches to the off-grid state and supplies powerto primary loads in backup mode. When the grid recovers, the inverter switchesback to the grid-tied state.

3.2.1 Grid-tied and Off-grid ESS Networking

Networking 1: Inverter + BatteriesThe grid-tied and off-grid ESS consists of the PV strings, LUNA2000 batteries,inverter, AC switch, load, Backup Box, PDU, Smart Power Sensor and grid. The gridconnection status of the inverter is switched by using the Backup Box.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 30

Page 37: User Manual - Amazon Web Services

Figure 3-10 Basic networking of the parallel off-grid ESS (dashed boxes indicateoptional components)

NO TE

The primary load power does not exceed the max off-grid output power of the Inverter.

Networking 2: Inverter (with Batteries) + Inverter (Without Batteries)The grid-tied and off-grid ESS supports inverter cascading. One inverter connectsto and manages the batteries. The Backup Box can connect to only one inverteroutput. The batteries, power meter, and Smart Dongle need to be connected tothe same inverter.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 31

Page 38: User Manual - Amazon Web Services

Figure 3-11 Inverter (with batteries) + inverter (without batteries) (dashed boxesindicate optional components)

NO TE

When the grid charging function is enabled, the surplus power generated by the inverterwithout batteries can be used to charge the inverter connected to batteries.

Networking 3: Inverter (with Batteries) + Inverter (with Batteries)A maximum of three inverters can be cascaded in the grid-tied and off-grid ESS.The batteries, power meter, and Smart Dongle need to be connected to the sameinverter.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 32

Page 39: User Manual - Amazon Web Services

Figure 3-12 Inverter (with batteries) + inverter (with batteries) (dashed boxesindicate optional components)

NO TE

The parameters of each battery need to be set separately. When the grid charging functionis enabled, the surplus power generated by one inverter can be used to charge the otherinverter.

WARNING

In the off-grid state, the output phases of cascaded inverters are different. Theload outputs of the Backup Boxes connected to each inverters cannot beconnected in parallel. As shown in the following figure, the P-1 output isconnected to primary O-1 and the P-2 output is connected to O-2. The P-1 andP-2 load outputs cannot be connected in parallel.

(A) PV string (B) DC switch (C) SUN2000

(D) AC switch (E) ACDU (F) Smart Power Sensor

(G) Power grid (H) LUNA2000 (I) 4G Smart Dongle

(J) WLAN-FE SmartDongle

(K) Router (L) FusionSolarmanagement system

(M) FusionSolar app (N) Load (O) Important Load

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 33

Page 40: User Manual - Amazon Web Services

(P) Backup

NO TE

indicates a power cable, indicates a signal cable, indicateswireless communication.

3.2.2 Setting the Grid-tied and Off-grid ESS ModeThe grid-tied and off-grid ESS switches the inverter to the grid connection statusthrough the Backup Box. When the grid fails, the ESS supplies power to primaryloads in backup mode. When the grid recovers, the ESS automatically switchesback to the grid-tied mode.

● This mode can be used together with the self-consumption or time-of-usemode.

– When the grid is normal, the self-consumption or time-of-use mode isused.

– After the grid fails, the ESS switches to the power backup mode. Thebattery backup time depends on the battery SOC when the grid fails.(The battery SOC for power backup can be set based on customerrequirements.)

Enabling Off-grid Mode

On the home screen, choose Settings > Feature parameters and enable Off-gridmode.

Figure 3-13 Backup power setting

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 34

Page 41: User Manual - Amazon Web Services

Table 3-5 Grid-tied and off-grid parameter setting

Parameter Description Value Range

Off-grid mode If this parameter is set to Enable, the ESSswitches to the off-grid mode when the gridfails.

● Enable● Disable

Backup powerSOC

Sets the backup power SOC. In grid-tiedmode, the battery does not discharge whenit is discharged to the backup power SOC.When the grid fails, loads are powered inbackup mode.

[20%, 100%]

Grid-tied/Off-grid modeswitching

If this parameter is set to Automaticswitching, the system switches to the off-grid mode when the grid fails, and switchesto the grid-tied mode when the gridrecovers.

● Automaticswitching

● Manualswitching

Setting a Working ModeThe grid-tied and off-grid ESS mode can be used together with the self-consumption or time-of-use mode. Enable Off-grid mode during site deployment.For details about how to set the self-consumption or time-of-use mode, see 3.1.2Setting the Grid-tied ESS Mode.

3.3 Pure Off-grid ESSThe pure off-grid ESS is mainly used in the scenario where there is no grid and thesystem operates in pure off-grid mode. The pure off-grid ESS stores the generatedPV energy in batteries and supplies power to loads when the PV energy isinsufficient or there is no PV energy at night.

3.3.1 Pure Off-grid ESS NetworkingThe pure off-grid ESS consists of the PV strings, LUNA2000 batteries, inverter, ACswitch, and load. In off-grid mode, PV strings and batteries must be configured.

The pure off-grid ESS supports only a single inverter and does not support parallelconnection of inverters.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 35

Page 42: User Manual - Amazon Web Services

Figure 3-14 Off-grid ESS (dashed boxes indicate optional components)

(A) PV string (B) DC switch (C) SUN2000

(D) AC switch (E) ACDU (H) LUNA2000

(I) 4G Smart Dongle (J) WLAN-FE Smart Dongle (K) Router

(L) FusionSolar managementsystem

(M) FusionSolar app (N) Load

NO TE

indicates a power cable, indicates a signal cable, indicateswireless communication.

3.3.2 Setting the Pure Off-grid ESS ModeThe inverter works in off-grid mode. When the sunlight is sufficient, the ESSsupplies power to loads and stores surplus PV energy in batteries. When thesunlight is insufficient or there is no sunlight, the batteries discharge to supplypower to loads. By default, the charge cutoff capacity of Huawei LUNA2000batteries is 100% and the discharge cutoff capacity is 15%. For details about howto change the charge or discharge cutoff capacity, see 6.3 BatteryCommissioning. In off-grid mode, you need to set the off-grid power grid code onthe Quick setting screen.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 36

Page 43: User Manual - Amazon Web Services

Figure 3-15 Setting the off-grid power grid code

NO TE

If the mains is unavailable, you need to set the off-grid power grid code. In off-grid mode,the battery must be configured.The battery does not discharge when it is discharged to the SOC. When sunlight is availableon the next day, the battery starts to supply power to loads after being charged to a certainamount of electricity.

LUNA2000-(5-30)-S0User Manual 3 Application Scenarios and Settings

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 37

Page 44: User Manual - Amazon Web Services

4 System Installation

4.1 Checking Before the Installation

Checking the Outer Packing

Before unpacking the battery, check the outer packing for damage, such as holesand cracks, and check the battery model. If any damage is found or the batterymodel is not what you requested, do not unpack the product and contact yourdealer as soon as possible.

Checking Deliverables

After unpacking the battery, check that the deliverables are intact and complete,and free from any obvious damage. If any item is missing or damaged, contactyour dealer.

NO TE

For details about the number of deliverables delivered with the battery, see the Packing Listin the packing case.

4.2 Preparing Tools and InstrumentsType Tools and Instruments

Installation

Hammer drill (with adrill bit of 8 mm)

Torque socket wrench Torque wrench

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 38

Page 45: User Manual - Amazon Web Services

Type Tools and Instruments

Diagonal pliers Wire strippers Torque screwdriver

Rubber mallet Utility knife Cable cutter

Crimping tool (model:PV-CZM-22100)

Cord end terminalcrimper

Disassembly andAssembly Tool (model:PV-MS-HZ open-endwrench)

Cable tie Vacuum cleaner Multimeter (DCvoltage measurementrange ≥ 600 V DC)

Marker Steel measuring tape Level

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 39

Page 46: User Manual - Amazon Web Services

Type Tools and Instruments

Hydraulic pliers Heat-shrink tubing Heat gun

Personal protectiveequipment (PPE)

Safety gloves Safety goggles Anti-dust mask

Safety boots

- -

4.3 Determining the Installation Position

Basic Requirements● Do not install the battery in a position where it is easy to touch because the

temperature of the chassis and heat sink is high when the battery is running.● Do not install the battery in areas with flammable or explosive materials.● Do not install the battery outdoors in salt-affected areas because it may

corrode and cause fires. A salt-affected area refers to the region within 500meters from the coast or prone to sea breeze. The regions prone to sea breezevary with weather conditions (such as typhoons and monsoons) or terrains(such as dams and hills).

● Do not install the battery in a position where children can touch it.

Installation Angle RequirementThe battery can be floor-mounted and wall-mounted. The installation anglerequirement is as follow:

● Do not install the battery at forward tilted, back tilted, side tilted, horizontal,or upside down positions.

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 40

Page 47: User Manual - Amazon Web Services

Installation Space Requirements● Reserve sufficient clearance around the battery to ensure sufficient space for

installation and heat dissipation.

Figure 4-1 Installation space

4.4 Equipment Installation

4.4.1 Floor-Mounted Installation

Installation PrecautionsFigure 4-2 shows the dimensions of mounting holes for a battery.

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 41

Page 48: User Manual - Amazon Web Services

Figure 4-2 Floor-mounted installation dimensions

Procedure

Step 1 Align the floor support with the wall surface and keep the support 10 mm to 15mm away from the wall surface. Level the hole positions using a level, and markthe hole positions for installing the floor support using a marker. Align themarking-off template with the surface of the floor mounting kit, determine thedrilling hole positions on the wall for securing the power control module, andmark the positions using a marker.

Step 2 Install the floor support.

D ANGER

When drilling holes, avoid the water pipes and power cables buried in the wall.

NO TE

M6x60 expansion bolts delivered with the battery are used to install the floor support andpower control module. If the length and quantity of the bolts do not meet installationrequirements, prepare M6 stainless steel expansion bolts by yourself. The expansion boltsdelivered with the battery are mainly used for solid concrete walls and concrete floors. Ifother types of walls and floors are used, ensure that the walls and floors meet the load-bearing requirements and select the bolts by yourself.

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 42

Page 49: User Manual - Amazon Web Services

Figure 4-3 M6 expansion bolt structure diagram

(1) Bolt (2) Nut (3) Spring washer

(4) Flat washer (5) Expansion sleeve

NO TICE

● To prevent dust inhalation or contact with eyes, wear safety goggles and ananti-dust mask when drilling holes.

● Wipe away any dust in or around the holes and measure the hole distances. Ifthe holes are inaccurately positioned, drill holes again.

● Level the head of the expansion sleeve with the concrete wall or floor afterremoving the nut, spring washer, and flat washer. Otherwise, the mounting kitwill not be securely installed on the wall or ground.

● Loosen the nut, spring washer, and flat washer of the expansion bolt at thebottom.

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 43

Page 50: User Manual - Amazon Web Services

Figure 4-4 Installing expansion bolts

Step 3 Place the first battery expansion module on the floor support, install theconnecting pieces on both sides, and tighten the four screws. Install the remainingbattery expansion modules and power control module from bottom to top.

WARNING

After installing a module, install and tighten the connecting pieces and screws onthe left and right sides of the module, and then install the next module.

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 44

Page 51: User Manual - Amazon Web Services

Figure 4-5 Installing the battery expansion modules and power control module

Step 4 Secure the power control module to the wall.

WARNING

The power control module must be fixed on the wall to prevent it from fallingdown.

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 45

Page 52: User Manual - Amazon Web Services

Figure 4-6 Fixing the power control module

----End

4.4.2 Wall-Mounted Installation

Installation PrecautionsFigure 4-7 shows the dimensions of mounting holes for the battery on the wall.

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 46

Page 53: User Manual - Amazon Web Services

Figure 4-7 Wall-mounted installation dimensions

Procedure

Step 1 Determine the positions for drilling holes using the marking-off template. Levelthe positions of mounting holes using a level, and mark the positions with amarker.

Step 2 Install the mounting kit.

D ANGER

When drilling holes, avoid the water pipes and power cables buried in the wall.

NO TE

M12x60 expansion bolts delivered with the battery are used to fix the wall mountingsupport. If the length and quantity of the bolts do not meet installation requirements,prepare M12 stainless steel expansion bolts by yourself.M6x60 expansion bolts delivered with the battery are used to fix the power control module.If the length and quantity of the bolts do not meet installation requirements, prepare M6stainless steel expansion bolts by yourself.

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 47

Page 54: User Manual - Amazon Web Services

Figure 4-8 Wall-mounted installation

Step 3 Place the first battery expansion module on the wall-mounted support, install theleft and right connective pieces, and install the second battery expansion module,third battery expansion module, and power control module from bottom to top.

WARNING

After installing a module, install and tighten the connecting pieces and screws onthe left and right sides of the module, and then install the next module.

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 48

Page 55: User Manual - Amazon Web Services

Step 4 Secure the power control module to the wall.

WARNING

The power control module must be fixed on the wall to prevent the battery fromfalling down.

Figure 4-9 Fixing power control module

----End

LUNA2000-(5-30)-S0User Manual 4 System Installation

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 49

Page 56: User Manual - Amazon Web Services

5 Electrical Connection

Precautions

D ANGER

Before connecting cables, ensure that the DC switch on the battery and all theswitches connected to the battery are set to OFF. Otherwise, the high voltage ofthe battery may result in electric shocks.

WARNING

● The equipment damage caused by incorrect cable connections is not coveredunder any warranty.

● Only certified electricians are allowed to connect cables.● Operation personnel must wear proper PPE when connecting cables.

NO TE

The cable colors shown in the electrical connection diagrams provided in this chapter arefor reference only. Select cables in accordance with local cable specifications (green-and-yellow cables are only used for PE).

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 50

Page 57: User Manual - Amazon Web Services

5.1 Preparing Cables

Figure 5-1 Battery cable connections

(A) PV string (B) DC switch (C) SUN2000

(D) AC switch (E) ACDU (F) Smart Power Sensor

(G) Power grid (H) LUNA2000 (M) FusionSolar app

(N) Load (O) Important Load (P) Backup

Table 5-1 Cables prepared by the customer

No. Cable Type RecommendedSpecifications

Source

1 DC inputpower cable

(inverter tobattery andbattery tobattery)

Common outdoorPV cable in theindustry

● Conductorcross-sectionalarea: 4–6 mm2

● Cable outerdiameter: 5.5–9mm

Preparedby thecustomer

2 Signal cable(inverter tobattery andbattery tobattery)

Outdoor shieldedtwisted pair cable (8cores)

● Conductorcross-sectionalarea: 0.20–0.35mm2

● Cable outerdiameter: 6.2–7mm

Preparedby thecustomer

3 Ground cable Single-core outdoorcopper cable

● 10 mm2 Preparedby thecustomer

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 51

Page 58: User Manual - Amazon Web Services

Table 5-2 Cables delivered with the battery

No. Cable Type Source

1 DC inputpower cable(powercontrolmodule tobatteryexpansionmodule)

Common outdoor PV cable in the industry Deliveredwith theproduct

2 Signal cable(powercontrolmodule tobatteryexpansionmodule)

Outdoor shielded twisted pair cable Deliveredwith theproduct

3 Ground cable Single-core outdoor copper cable Deliveredwith theproduct

NO TE

● indicates a power cable, indicates a signal cable, indicateswireless communication, indicates a ground cable.

● The minimum cable diameter must comply with local cable standards.● The factors that affect cable selection include the rated current, cable type, routing

mode, ambient temperature, and maximum expected line loss.● The DC input power cable and signal cable between the battery and the inverter must

be less than or equal to 10 m.

5.2 Internal Electrical Connections of the BatteryNO TE

Internal cables are delivered with the battery. For details, see the Packing List in the packingcase.

5.2.1 Installing an Internal Ground Cable

Precautions

D ANGER

Ensure that the PE cable is securely connected. Otherwise, electric shocks mayoccur.

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 52

Page 59: User Manual - Amazon Web Services

NO TE

It is recommended that silica gel or paint be used around the ground terminal after the PEcable is connected.

Step 1 Connect the PE cable to the battery power control modules and battery expansionmodules.

Figure 5-2 Connecting the internal PE cable

----End

5.2.2 Installing Internal DC TerminalsStep 1 Insert the positive and negative connectors delivered with the battery into the

positive and negative battery cascading terminals (B+ and B–).

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 53

Page 60: User Manual - Amazon Web Services

Figure 5-3 DC power cable connection inside the battery

NO TE

The DC terminals between the power control module and the battery expansion modulesuse the DC connection cable (Amphenol terminal) delivered with the battery.

NO TICE

After the positive and negative connectors snap into place, pull the DC inputpower cables back to ensure that they are connected securely.

----End

5.2.3 Connecting Internal Signal Cables

Connecting Signal Cables Between the Power Control Module and BatteryExpansion Modules

Connect the communications terminals of the power control module and batteryexpansion modules in sequence and secure them using cable clips.

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 54

Page 61: User Manual - Amazon Web Services

Figure 5-4 Signal cable connections between the power module and batterymodules

NO TE

When a communications terminal is connected to a single network cable, a waterproofrubber plug must be installed.

5.3 External Electrical Connections of the Battery

Routing Cables Out of the Cable HoleCut a cable hole based on the cabling mode, and route external cables throughthe cable hole.

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 55

Page 62: User Manual - Amazon Web Services

Figure 5-5 Routing cables out of the cable hole

NO TICE

Before connecting external cables, route the cables through the cable hole toavoid disconnecting after installation.

5.3.1 Installing a PE Cable

Precautions

D ANGER

Ensure that the PE cable is securely connected. Otherwise, electric shocks mayoccur.

NO TE

It is recommended that silica gel or paint be used around the ground terminal after the PEcable is connected.

Procedure

Step 1 Crimp an OT terminal.

NO TICE

● Avoid scratching the core wire when stripping a cable.● The cavity formed after the conductor crimp strip of the OT terminal is crimped

must wrap the core wires completely. The core wires must contact the OTterminal closely.

● Wrap the wire crimping area with heat shrink tubing or insulation tape. Theheat shrink tubing is used as an example.

● When using a heat gun, protect the equipment from being scorched.

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 56

Page 63: User Manual - Amazon Web Services

Figure 5-6 Crimping an OT terminal

(A) Core wire (B) Insulation layer (C) Heat shrink tubing

(D) Heat gun (E) Hydraulic pliers

Step 2 Connect the ground point of the power control module to the external groundpoint.

Figure 5-7 Grounding the PE cable

NO TE

● It is recommended that silica gel or paint be used around the ground terminal after thePE cable is connected.

----End

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 57

Page 64: User Manual - Amazon Web Services

5.3.2 Installing DC Input Power Cables

Connect DC input power cables to the inverterInsert the positive and negative battery connectors (Staubli) into thecorresponding DC input terminals (BAT+ and BAT–).

NO TE

The DC input terminals (BAT+ and BAT–) on the left and right sides of the battery are thesame.

Step 1 Assemble DC connectors.

Figure 5-8 Assembling DC connectors

CA UTION

Use Staubli MC4 positive and negative metal terminals and DC connectors. Usingincompatible positive and negative metal terminals and DC connectors may resultin serious consequences. The caused equipment damage is not covered under anywarranty or service agreement.

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 58

Page 65: User Manual - Amazon Web Services

NO TICE

● Keep the DC input BAT+ cable and BAT– cable close to each other.● Cables with high rigidity, such as armored cables, are not recommended as DC

input power cables to avoid cable folding.● Before assembling DC connectors, label the cable polarities correctly to ensure

correct cable connections.● After crimping the positive and negative metal terminals, pull the DC input

power cables back to ensure that they are connected securely.● Insert the crimped metal terminals of the positive and negative power cables

into the appropriate positive and negative connectors. Then pull back the DCinput power cables to ensure that they are connected securely.

Step 2 Insert the positive and negative connectors into the battery terminals (BAT+ andBAT-) on the switch and connect the other end to the cascaded battery.

Figure 5-9 Connecting battery cables

----End

5.3.3 Installing a Signal Cable

Connecting the Signal Cable between the Power Control Module and theInverter

NO TICE

When laying out a signal cable, separate it from power cables and keep it awayfrom strong interference sources to prevent communication interruption.

The COM port definitions on both sides of the power control module are thesame. It is recommended that the COM port on the switch side be connected tothe inverter and the COM port on the other side be connected to the cascadedbattery.

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 59

Page 66: User Manual - Amazon Web Services

Figure 5-10 Signal cable ports

Table 5-3 COM port definition

No. Label Definition Description

1 PE Shield layer grounding Shield layer grounding

2 Enable- Enable signal GND Connects to the enable signalGND of the inverter.

3 Enable+ Enable signal+ Connects to the positiveenable signal of the inverter.

4 485A1 RS485A, RS485differential signal+

Connects to the RS485 signalport of the inverter.

5 485A2 RS485A, RS485differential signal+

6 485B1 RS485B, RS485differential signal–

Connects to the RS485 signalport of the inverter.

7 485B2 RS485B, RS485differential signal–

8 CANL Extended CAN bus port Used for signal cablecascading in batterycascading scenarios.

9 CANH Extended CAN bus port Used for signal cablecascading in batterycascading scenarios.

10 PE Shield layer grounding Shield layer grounding

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 60

Page 67: User Manual - Amazon Web Services

TerminalsNO TE

● Identify the signal terminal pins according to the following figures, and connect cablesaccording to Table 5-3. When you insert the communications terminal of the powercontrol module, the silk screens on the two sides of the communications port aredifferent. Insert the communications terminal according to the following figures.

● The communications terminals on the inverter side need to be connected to RS485+\RS485-, EN+\EN-, and PE.

Figure 5-11 Inserting the terminal

Connecting a Signal CablePrepare signal cable terminals for connecting to the inverter.

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 61

Page 68: User Manual - Amazon Web Services

Figure 5-12 Connecting inverter terminals

5.4 (Optional) Cascading Batteries

Battery Cascading Cable Connection

Figure 5-13 Battery cascading cable connection

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 62

Page 69: User Manual - Amazon Web Services

Connecting Cascading DC Input Power Cables (Cascading)

Connect the DC input terminals (BAT+ and BAT–) between the power controlmodule by referring to 5.3.2 Installing DC Input Power Cables.

TerminalsNO TE

● Identify the signal terminal pins according to the following figures, and connect cablesaccording to Table 5-3. When you insert the communications terminal of the powercontrol module, the silk screens on the two sides of the communications port aredifferent. Insert the communications terminal according to the following figures.

● The communications terminals on the cascading side need to be connected to RS485+\RS485-, EN+\EN-, CANH\CANL, and PE.

Figure 5-14 Inserting the terminal

Connecting a Signal Cable (Cascading)

Prepare a signal cable terminal for connecting the power control module.

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 63

Page 70: User Manual - Amazon Web Services

Figure 5-15 Cascading communication terminal

5.5 Installing the CoverAfter electrical connections are complete, check that cables are correctly andsecurely connected, install the external protective cover, and secure it using screws.

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 64

Page 71: User Manual - Amazon Web Services

Figure 5-16 Installing the cover

LUNA2000-(5-30)-S0User Manual 5 Electrical Connection

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 65

Page 72: User Manual - Amazon Web Services

6 System Commissioning

6.1 Verification Before Power-On

Table 6-1 Check items and acceptance criteria

No. Check Item Acceptance Criteria

1 Battery installation The installation is correct and reliable.

2 Cables routing Cables are routed properly as requiredby the customer.

3 Cable tie Cable ties are evenly distributed and noburr exists.

4 Grounding The PE cable is connected correctly,securely, and reliably.

5 Switch The DC switch and all switchesconnected to the battery are OFF.

6 Cable connection The AC output power cable, DC inputpower cable, battery cable, and signalcable are connected correctly, securely,and reliably.

7 Unused terminal and port Unused terminals and ports are lockedby watertight caps.

8 Installation environment The installation space is proper, andthe installation environment is cleanand tidy.

LUNA2000-(5-30)-S0User Manual 6 System Commissioning

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 66

Page 73: User Manual - Amazon Web Services

6.2 System Power-On

NO TICE

After turning on the battery switch, power on the inverter. For details about howto power on the inverter, see the quick guide for the corresponding inverter model.

NO TE

If no PV module is configured, press the black start button first.

Turn on the DC switch on the battery. After the battery is installed and poweredon for the first time, the ring LED blinks for three circles. Observe the batteryindicator to check the running status.

LED IndicatorsLED indicator description

Table 6-2 LED indicators

Category Status (Blinking at LongIntervals: On for 1s and thenOff for 1s; Blinking at ShortIntervals: On for 0.2s andthen Off for 0.2s)

Description

Running indicator N/A

Steadygreen

Steady green Operating mode

Blinkinggreen slowly

Blinking greenslowly

Standby mode

Off Off Hibernation mode

Blinking redfast

N/A Power control module environment alarm

N/A Blinking redfast

Battery expansion module environmentalarm

Steady red N/A The power control module is faulty.

N/A Steady red The battery expansion module is faulty.

Battery systemindicator

N/A

Green Battery level. Each bar indicates 10%.

LUNA2000-(5-30)-S0User Manual 6 System Commissioning

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 67

Page 74: User Manual - Amazon Web Services

Category Status (Blinking at LongIntervals: On for 1s and thenOff for 1s; Blinking at ShortIntervals: On for 0.2s andthen Off for 0.2s)

Description

Steady red The first three bars indicate the numberof faulty battery expansion modules.

6.3 Battery Commissioning

Download and install the FusionSolar app.

Download and install the latest FusionSolar app by referring to the quick guide forthe corresponding inverter model or the FusionSolar App Quick Guide. Thenregister the installer and create a PV plant and owner (skip this step if the accounthas been created). You can obtain the FusionSolar App Quick Guide by scanningthe following QR code.

Figure 6-1 FusionSolar App Quick Guide

6.3.1 Battery Deployment

Function

Add a battery and set the working mode on the quick settings screen of theinverter.

(Optional) Upgrading the Inverter and Dongle

When the app connects to the inverter, a message is displayed, asking you toupgrade the inverter version. Dongle V100R001C00SPC117 and later versionssupport LUNA2000 battery. But the Smart Dongle cannot be upgraded locally. Youneed to perform the upgrade through the management system. The operationprocedure will be updated later.

Quick Settings

Step 1 Log in to the FusionSolar app using the installer's account. Tap Quick Settings onthe home screen to add the battery and set the battery working mode. By default,the battery working mode is set to the maximum self-consumption mode. Tap ? toview the detailed settings, and select a working mode by referring to 3Application Scenarios and Settings.

LUNA2000-(5-30)-S0User Manual 6 System Commissioning

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 68

Page 75: User Manual - Amazon Web Services

Figure 6-2 Quick settings

----End

6.3.2 Battery Control

FunctionWhen the inverter connects to a battery, add the battery and set batteryparameters.

Adding a BatteryTo add a battery, choose Maintenance > Subdevice management on the homescreen.

LUNA2000-(5-30)-S0User Manual 6 System Commissioning

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 69

Page 76: User Manual - Amazon Web Services

Figure 6-3 Adding a battery

Parameters SettingsOn the home screen, choose Power adjustment > Battery control, and set thebattery parameters and working mode.

LUNA2000-(5-30)-S0User Manual 6 System Commissioning

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 70

Page 77: User Manual - Amazon Web Services

Figure 6-4 Battery control parameter setting

Parameter Description Value Range

Working mode For details, see the descriptionon the app screen.

● Maximum self-consumption

● Time-of-use● Fully fed to grid

Maximum chargepower (kW)

Retain this parameter to themaximum charge power.Additional configuration is notrequired.

● Charge: [0,Maximum chargepower]

Maximum dischargepower (kW)

Retain this parameter to themaximum discharge power.Additional configuration is notrequired.

● Discharge: [0,Maximumdischarge power]

End-of-chargecapacity (%)

Set the charge cutoff capacity. 90%–100%

End-of-dischargecapacity (%)

Set the discharge cutoffcapacity.

0%–20%

LUNA2000-(5-30)-S0User Manual 6 System Commissioning

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 71

Page 78: User Manual - Amazon Web Services

Parameter Description Value Range

Charge from grid If Charge from grid function isdisabled by default, complywith the grid chargerequirements stipulated in locallaws and regulations when thisfunction is enabled.

● Disable● Enable

Grid charge cutoffSOC

Set the grid charge cutoff SOC. [20%, 100%]

6.3.3 Querying the Battery StatusOn the home screen, tap Device monitoring on the home screen to view therunning status, level, power, and charge and discharge status of the battery.

Figure 6-5 Device monitoring

6.3.4 Battery Maintenance and UpgradeOn the home screen, choose Maintenance > Battery upgrade and set relatedparameters.

Forced Charge and Discharge

Step 1 Choose Maintenance > Battery maintenance > Forced charge and discharge,set forced charged and discharged parameters, and tap Submit.

LUNA2000-(5-30)-S0User Manual 6 System Commissioning

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 72

Page 79: User Manual - Amazon Web Services

Figure 6-6 Forced Charge and Discharge

Table 6-3 Description of forced charge/discharge parameters

Parameter Description Value Range

Charge/Discharge Specifies whether tocharge or discharge thebattery.

● Stop● Charge● Discharge

Charge/Discharge power(kW)

Specifies the forcedcharge/discharge power.

● Charge: [0, Maximumcharge power]

● Discharge: [0,Maximum dischargepower]

Charge/Discharge settingmode

Set the charge anddischarge mode.

● Duration● Charged/Discharged

energy

Charge/Dischargeduration (min)

Sets the charge anddischarge duration.

[0, 1440]

Remaining charge/discharge duration (min)

Indicates the remainingcharge and dischargeduration. This parametercannot be set.

-

Charged/Dischargedenergy (kWh)

Indicates the charged ordischarged battery level.This parameter cannotbe set.

-

Charged/Dischargedduration (min)

Indicates the chargedand discharged duration.This parameter cannotbe set.

-

LUNA2000-(5-30)-S0User Manual 6 System Commissioning

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 73

Page 80: User Manual - Amazon Web Services

----End

Downloading an Upgrade PackageDownloading an Upgrade Package

Step 1 When your phone is connected to a network, on the connection screen, tap inthe upper right corner, and then choose File download.

Figure 6-7 Downloading a file

Step 2 Download the device upgrade package and grid code when an update is detected.

Step 3 On the screen for downloading the upgrade package, tap Download.

----End

LUNA2000-(5-30)-S0User Manual 6 System Commissioning

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 74

Page 81: User Manual - Amazon Web Services

7 System Maintenance

7.1 System Power-Off

Precautions

WARNING

After the system powers off, the remaining electricity and heat may still causeelectric shocks and body burns. Therefore, wear protective gloves 5 minutes afterthe system is powered off before performing any operation on the battery.

After powering off the connected inverter, turn off the DC switch for the battery.

7.2 Routine MaintenanceTo ensure that the battery can operate properly for a long term, you are advisedto perform routine maintenance on it as described in this chapter.

CA UTION

Before cleaning the system, connecting cables, and ensuring the groundingreliability, power off the system.

Table 7-1 Maintenance checklist

Check Item Check Method MaintenanceInterval

Systemcleanliness

Check periodically that the heat sinksare free from obstacles and dust.

Once every 6 to 12months

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 75

Page 82: User Manual - Amazon Web Services

Check Item Check Method MaintenanceInterval

Systemrunning status

● Check that the battery is notdamaged or deformed.

● Check that the battery does notgenerate abnormal sound when it isin operation.

● Check that the battery parametersare correctly set when the battery isrunning.

Once every 6months

ElectricalConnection

● Check that cables are secured.● Check that cables are intact, and

that in particular, the parts touchingthe metallic surface are notscratched.

● Check that unused DC inputterminals, battery terminals, andCOM ports are locked by watertightcaps.

The first inspection is6 months after theinitialcommissioning.From then on, theinterval can be 6 to12 months.

Groundingreliability

Check that ground cables are securelyconnected.

The first inspection is6 months after theinitialcommissioning.From then on, theinterval can be 6 to12 months.

7.3 TroubleshootingAlarm severities are defined as follows:

● Major: The battery shuts down or some functions are abnormal due to a fault.● Minor: Some components of the battery are faulty but the battery can still

work.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 76

Page 83: User Manual - Amazon Web Services

Table 7-2 Common alarms and troubleshooting measures

AlarmID

Alarm Name AlarmSeverity

Possible Cause Troubleshooting

3000 Low battery DC inputbus voltage

Major 1. The DC bus voltageof the battery is low.2. The battery DCswitch is OFF.3. The battery cablesare not correctlyconnected.

1. Turn off the inverterAC output switch,inverter DC inputswitch, and battery DCswitch, and wait for 5minutes.2. Check the cableconnections to the[Battery-1/2] powercontrol module byreferring to the quickinstallation guide.3. After checking thatthe battery powercables are correctlyconnected, turn on thebattery DC switch, ACoutput switch, andinverter DC inputswitch in sequence.4. If the alarm persists,contact your dealer orHuawei technicalsupport.

3001 Abnormal batterypower control module

Major An unrecoverable faulthas occurred on aninternal circuit of thebattery power controlmodule.

1. Turn off the inverterAC output switch,inverter DC inputswitch, and battery DCswitch, and wait for 5minutes.2. Turn on the batteryDC switch, inverter ACoutput switch, and DCinput switch.3. If the alarm persistson the [Battery-1/2]power control module(the battery faultindicator is steady on),contact your dealer orHuawei technicalsupport.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 77

Page 84: User Manual - Amazon Web Services

AlarmID

Alarm Name AlarmSeverity

Possible Cause Troubleshooting

3002 Battery power controlmoduleovertemperature

Minor 1. The installationposition of the batterypower control moduleis not well ventilated.2. The ambienttemperature isexcessively high.3. The battery powercontrol module isabnormal.

1. Check theventilation andwhether the ambienttemperature of the[Battery-1/2] powercontrol moduleexceeds the upperthreshold.2. If the ventilation ispoor or the ambienttemperature isexcessively high,improve theventilation and heatdissipation.3. If the ventilationand ambienttemperature arenormal, contact yourdealer or Huaweitechnical support.

3003 Battery power controlmodule fuse blown

Major The fuse of thebattery power controlmodule is blown.

1. Turn off the inverterAC output switch,inverter DC inputswitch, and battery DCswitch, and wait for 5minutes.2. Replace the fuse ofthe [Battery-1/2]power control module.3. Turn on the batteryDC switch, inverter ACoutput switch, andinverter DC inputswitch in sequence. Ifthe alarm persists,contact your dealer orHuawei technicalsupport.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 78

Page 85: User Manual - Amazon Web Services

AlarmID

Alarm Name AlarmSeverity

Possible Cause Troubleshooting

3004 Battery power controlmodule reverselyconnected

Major The positive andnegative terminals arereversely connectedwhen the batterypower control moduleconnects to theinverter.

1. Turn off the inverterAC output switch,inverter DC inputswitch, and battery DCswitch, and wait for 5minutes.2. Check the cableconnections to the[Battery-1/2] powercontrol module byreferring to the quickinstallation guide.3. After checking thatthe battery powercables are correctlyconnected, turn on thebattery DC switch, ACoutput switch, andinverter DC inputswitch in sequence.4. If the alarm persists,contact your dealer orHuawei technicalsupport.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 79

Page 86: User Manual - Amazon Web Services

AlarmID

Alarm Name AlarmSeverity

Possible Cause Troubleshooting

3005 Battery power controlmodule DC switch OFF

Warning 1. The DC switch ofthe battery powercontrol module is OFF.2. The DC bus cable tothe battery powercontrol module isdisconnected.

1. Turn off the inverterAC output switch,inverter DC inputswitch, and battery DCswitch, and wait for 5minutes.2. Check the cableconnections to the[Battery-1/2] powercontrol module byreferring to the quickguide.3. After checking thatthe battery powercables are correctlyconnected, turn on thebattery DC switch, ACoutput switch, andinverter DC inputswitch in sequence.4. If the alarm persists,contact your dealer orHuawei technicalsupport.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 80

Page 87: User Manual - Amazon Web Services

AlarmID

Alarm Name AlarmSeverity

Possible Cause Troubleshooting

3006 Abnormal batteryexpansion module

Major An unrecoverable faulthas occurred on aninternal circuit of abattery expansionmodule.

1. Check that thepower cables andcommunicationscables are correctlyconnected to the[Battery-1/2 batteryexpansionmodule-1/2/3] batteryexpansion modules.2. Send a shutdowncommand on the app,turn off the inverterAC output switch,inverter DC inputswitch, and battery DCswitch, and wait for 5minutes.3. Turn on the batteryDC switch, inverter ACoutput switch, and DCinput switch.4. If the alarm persists,contact your dealer orHuawei technicalsupport.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 81

Page 88: User Manual - Amazon Web Services

AlarmID

Alarm Name AlarmSeverity

Possible Cause Troubleshooting

3007 Battery expansionmodule cabledisconnected

Major 1. A battery expansionmodule cable isdisconnected.2. A battery expansionmodule is abnormal.

1. Turn off the inverterAC output switch,inverter DC inputswitch, and battery DCswitch, and wait for 5minutes.2. Check whether thepower cable issecurely connected tothe [Battery-1/2battery expansionmodule-1/2/3] batteryexpansion modules(the terminal is looseor disconnected, orthe cable isdisconnected). Fordetails, see the quickinstallation guide.3. After checking thatthe cables arecorrectly connected,turn on the battery DCswitch, AC outputswitch, and inverterDC input switch insequence.4. If the alarm persists,contact your dealer orHuawei technicalsupport.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 82

Page 89: User Manual - Amazon Web Services

AlarmID

Alarm Name AlarmSeverity

Possible Cause Troubleshooting

3008 Battery expansionmoduleovertemperature

Minor 1. The batteryinstallation position isnot well ventilated.2. The ambienttemperature isexcessively high.3. The battery powercontrol module isabnormal.

1. Check theventilation andwhether the ambienttemperature of the[Battery-1/2 batteryexpansionmodule-1/2/3] batteryexpansion modulesexceeds the upperthreshold.2. If the ventilation ispoor or the ambienttemperature isexcessively high,improve theventilation and heatdissipation.3. If the ventilationand ambienttemperature arenormal, contact yourdealer or Huaweitechnical support.

3009 Battery expansionmodule lowtemperature

Minor 1. The ambienttemperature isexcessively low.2. A battery expansionmodule is abnormal.

1. Check whether theambient temperaturein the installationpositions of the[Battery-1/2 batteryexpansionmodule-1/2/3] batteryexpansion modules islower than the lowerthreshold.2. If the ambienttemperature isexcessively low,improve theinstallationenvironment.3. If the alarm persistsafter the ambienttemperature becomesnormal, contact yourdealer or Huaweitechnical support.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 83

Page 90: User Manual - Amazon Web Services

AlarmID

Alarm Name AlarmSeverity

Possible Cause Troubleshooting

3010 Battery expansionmodule short circuit

Major 1. The batteryexpansion module isshort-circuited.2. A battery expansionmodule is abnormal.

1. Turn off the inverterAC output switch,inverter DC inputswitch, and battery DCswitch, and wait for 5minutes.2. Check the powercable connection tothe [Battery-1/2battery expansionmodule-1/2/3] batteryexpansion modules byreferring to the quickinstallation guide. Ifthe cable is damagedor short-circuited,replace it.3. After checking thatthe cables arecorrectly connected,turn on the battery DCswitch, AC outputswitch, and inverterDC input switch insequence.4. If the alarm persists,contact your dealer orHuawei technicalsupport.

3011 Battery expansionmodule undervoltage

Warning The voltage of abattery expansionmodule is low.

If the sunlight issufficient or ACreverse charging isallowed, the[Battery-1/2 batteryexpansionmodule-1/2/3] batteryexpansion modulescan be charged whenthe inverter is running.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 84

Page 91: User Manual - Amazon Web Services

AlarmID

Alarm Name AlarmSeverity

Possible Cause Troubleshooting

3012 Abnormal batterypower control moduleparallelcommunication

Major The battery powercontrol modules of theparallel system fail tocommunicate witheach other.

1. Send a shutdowncommand on the app,turn off the inverterAC output switch,inverter DC inputswitch, and battery DCswitch, and wait for 5minutes.2. Check that thecommunications cableis correctly connectedbetween the[Battery-1/2] batterypower controlmodules of theparallel system.3. After checking thatthe cables arecorrectly connected,turn on the battery DCswitch, AC outputswitch, and inverterDC input switch insequence.4. If the alarm persists,contact your dealer orHuawei technicalsupport.

3013 Abnormal batteryexpansion modulecommunication

Major The battery powercontrol module fails tocommunicate with thebattery expansionmodules.

1. Turn off the batteryDC switch.2. Check that thepower cables andcommunicationscables are correctlyconnected to the[Battery-1/2 batteryexpansionmodule-1/2/3] batteryexpansion modules.3. After checking thatcables are correctlyconnected, turn on thebattery DC switch.4. If the alarm persists,contact your dealer orHuawei technicalsupport.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 85

Page 92: User Manual - Amazon Web Services

7.4 Battery Storage and Recharge

Battery Acceptance Inspection

A battery recharge label must be put on the battery packing case. The rechargelabel should contain the latest charge time and the next recharge time.

Battery Storage Requirements

1. Place batteries according to the signs on the packing case during storage. Donot put batteries upside down or sidelong.

2. Stack battery packing cases by complying with the stacking requirements onthe external package.

3. Handle batteries with caution to avoid damage.

4. The storage environment requirements are as follows:

– Ambient temperature: -10–55°C; recommended storage temperature: 20–30°C

– Relative humidity: 5% to 80%

– Place batteries in a dry and clean place with proper ventilation.

– Place batteries in a place that is away from corrosive organic solvents andgases.

– Keep batteries away from direct sunlight.

– Keep batteries at least 2 meters away from heat sources.

5. The batteries in storage must be disconnected from external devices. Theindicators (if any) on the batteries should be off.

6. AC mains input voltage requirements in the recharge places: single-phasepower grid: 220 V/230 V/240 V, ±10%; three-phase voltage: 380 V/400 V,±10%.

7. The warehouse keeper should collect battery storage information everymonth and periodically report the battery inventory information to theplanning department. The batteries that have been stored for nearly 15months (-10–25°C) 、9 months (25–35°C) or 6 months (35–55°C) should berecharged in a timely manner.

8. Regional offices or organizations should not store batteries.

9. Batteries should be delivered based on the "first in, first out" rule.

10. After the battery production test is complete and before the batteries arestored, the batteries must be recharged to at least 50% of the SOC.

Conditions for Judging Overdue Storage

It is recommended that batteries not be stored for a long period. They should beused soon after being deployed onsite. The batteries should be handled accordingto the following requirements.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 86

Page 93: User Manual - Amazon Web Services

Table 7-3 Lithium battery recharge interval

RequiredStorageTemperature

Actual StorageTemperature

RechargeInterval

Remarks

-10°C–55°C T≤-10℃ Not allowed Not reaching thetime for recharge:Use the batteriesas soon aspossible.Reaching the timefor recharge:Recharge thebatteries.The total storageduration shouldnot exceed thewarranty period.

-10℃<T≤25℃ 15 months

25℃<T≤35℃ 9 months

35℃<T≤55℃ 6 months

55℃<T Not allowed

1. Dispose of deformed, damaged, or leaking batteries directly irrespective ofhow long they have been stored.

2. The storage duration starts from the latest charge time labeled on the batterypackage. If a battery is qualified after recharge, update the latest charge timeand the next recharge time (next recharge time = latest charge time +recharge interval) on the label.

3. The maximum power storage period of a lithium battery is three years. Alithium battery can be recharged at most for three times within the threeyears. For example, it can be recharged every 8 months or every 12 months. Itis recommended that batteries be scrapped if the maximum allowable storageperiod and recharging times are exceeded.

4. If a lithium battery is stored for a long time, capacity loss may occur. After alithium battery is stored for 12 months in the recommended storagetemperature, the irreversible capacity loss rate is 3%–10%. If customersperform the discharge test according to the specifications, they may fail topass the test if the storage capacity of the battery is not 100% of the ratedcapacity.

Inspection Before Recharge1. Before recharging a battery, you need to check its appearance. Recharge the

battery if it is qualified or dispose of it if not.2. The battery is qualified if it is free from the following symptoms:

– Deformation– Shell damage– Leakage

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 87

Page 94: User Manual - Amazon Web Services

Battery Recharging Scenarios

Three-Phase Power Supply Scenario

● The SUN2000-10KTL-M1 provides 10 kW power to charge batteries. It allowstwo charge units (six battery packs) to be charged at the same time. Othermodels can charge batteries with a power of less than 10 kW.

Figure 7-1 Networking diagram for three-phase power supply scenario

(C) SUN2000-10KTL-M1 (D) AC switch (E) ACDU

(G) Power grid (H) LUNA2000 (M) FusionSolar app

Single-phase power supply scenario

● The SUN2000-(3KTL-6KTL)-L1 provides 3 kW power to charge batteries. Itallows one charge unit (three battery packs) to be charged at the same time.

Figure 7-2 Networking diagram for single-phase power supply scenario

(C) SUN2000-(3KTL-6KTL)-L1 (D) AC switch (E) ACDU

(G) Power grid (H) LUNA2000 (M) FusionSolar app

NO TE

indicates a power cable, indicates a signal cable, indicateswireless communication.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 88

Page 95: User Manual - Amazon Web Services

Battery Recharging Cable ConnectionConnect cables by referring to 5 Electrical Connection. If two charge units needto be charged at the same time, cascade the batteries by referring to 5.4(Optional) Cascading Batteries.

Figure 7-3 Cable connection diagram

Battery Power-On and Commissioning● For details about how to store and recharge the battery, see the Lithium

Battery Storage and Recharge Guide.

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 89

Page 96: User Manual - Amazon Web Services

NO TICE

● Ensure that the charge process is supervised to prevent any abnormality.● If a battery experiences an abnormality such as bulging or smoking, stop

charging immediately and dispose of it.● Ensure that only trained professionals perform recharge operations.● After turning on the battery switch, power on the inverter. For details about

how to power on the inverter, see the quick guide for the correspondinginverter model.

● When the battery SOC is 0%, the battery cannot be activated by holding theblack start button. The battery can be started only after both the DC and ACpower supplies are connected.

● It is recommended that the battery be charged to 50% SOC. Long-term storagewill cause capacity loss, after a lithium battery is stored for 12 months in therecommended storage temperature, the irreversible capacity loss rate is 3%–10%.

Step 1 Connect power cables and communications cables correctly.

Step 2 Turn on the battery power pack switch by turning the DC switch to ON.

Step 3 Turn on the AC switch between the inverter and the grid.

Step 4 Check that LED1 is steady green, LED2 is steady green, and LED3 is blinking greenslowly.

Step 5 Hold down the black start button for 5s to activate the battery. The power controlmodule LED blinks three times and then the green indicator is steady on. Thebattery comprehensive LED blinks three times and then the green indicator issteady on. The ring LED blinks three circles.

Step 6 Connect the FusionSolar app to the inverter, the operation procedure will beupdated later.

Step 7 Confirm that the recharge is complete if five indicators of the ring LED are on andthe comprehensive LED of the battery expansion modules is steady green.

Step 8 After the battery is charged, switch off the inverter input AC circuit breaker andthen the battery input circuit breaker. If other batteries need to be charged, repeatthe preceding steps.

----End

LUNA2000-(5-30)-S0User Manual 7 System Maintenance

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 90

Page 97: User Manual - Amazon Web Services

8 Technical Specifications

8.1 LUNA2000-5KW-C0TechnicalSpecifications

LUNA2000-5KW-C0

Rated charge anddischarge power

5 kW

Nominal voltage(single-phase system)

360 V

Operating voltage(single-phase system)

350–560 V

Nominal voltage(three-phase system)

600 V

Operating voltage(three-phase system)

600–980 V

Dimensions (H x W xD)

240 mm x 670 mm x 150 mm

Weight 12 kg

Cooling mode Free cooling

IP rating IP66

Communications RS485 and CAN (for cascading)

Operatingtemperature

–25°C to +55°C

Operating humidity 5%–95% RH

Maximum operatingaltitude

4000 m

LUNA2000-(5-30)-S0User Manual 8 Technical Specifications

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 91

Page 98: User Manual - Amazon Web Services

8.2 LUNA2000-5-E0TechnicalSpecifications

LUNA2000-5-E0

Nominal availablecapacity

5 kWh

Battery cell type Li-ion

Dimensions (H x W xD)

360 mm x 670 mm x 150 mm

Weight 50kg

Cooling mode Free cooling

IP rating IP66

Operatingtemperature

–10°C to +55°C

Maximum operatingaltitude

4000 m

LUNA2000-(5-30)-S0User Manual 8 Technical Specifications

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 92

Page 99: User Manual - Amazon Web Services

9 FAQ

9.1 How Do I Replace a Fuse?Step 1 Power off the system. For details, see 7.1 System Power-Off.

WARNING

After the system is powered off, the remaining electricity and heat still exist in thechassis, which may cause electric shocks or burns. Therefore, you need to wearprotective gloves and perform operations 5 minutes after the system is poweredoff.

Step 2 Loosen the screws on the fuse shell.

Figure 9-1 Removing the screw shell

Step 3 Lift the fuse box opening, remove the fuse, insert a new fuse into the slot, andclose the fuse box. If you hear a click sound and the bulge on the side is inside thebox, the fuse box is properly installed.

LUNA2000-(5-30)-S0User Manual 9 FAQ

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 93

Page 100: User Manual - Amazon Web Services

Figure 9-2 Replacing a fuse

----End

Fuse Specifications

Table 9-1 Fuse specifications

Fuse Required Specifications

Type Lower Limit Typical Value Upper Limit

Component type - Fuse -

Fuse type - Fast blow fuse -

Rated voltage (VAC&V DC)

1100 V DC - -

Rated current 32 A - -

Breaking capacity 10 kA - -

Nominal fusingheat I2T

- - -

Cold resistancevalue

- - 0.005 Ω

Packagedimensions (thedimensiontolerance shouldbe specified in thespecificationsprovided by thesupplier)

- 14 mm x 51 mm -

LUNA2000-(5-30)-S0User Manual 9 FAQ

Issue 02 (2020-11-20) Copyright © Huawei Technologies Co., Ltd. 94

Page 101: User Manual - Amazon Web Services

A Acronyms and Abbreviations

A

APP application

B

BMS battery management system

D

DC direct current

F

FIT feed-in tariff

E

EMI electromagnetic interference

P

PV photovoltaic

V

VPP virtual power plant

LUNA2000-(5-30)-S0User Manual A Acronyms and Abbreviations