8
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Fixing hole Bayonet Front View Back View

User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View

Embed Size (px)

Citation preview

Page 1: User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View

User Interface – Switch Panel

6 Gang Switch Panel Configuration guide

RS485 Terminal

Fixing hole

Fixing hole

Bayonet

Front View Back View

Page 2: User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View

Subnet ID and Device ID

Remark

MAC Address

Backlit brightness setting

LED indicator brightness of the buttons

Switc

h Pa

nel

Basic information

Page 3: User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View

Switc

h Pa

nel

Key No.

Remark

Switch Mode

Control Target

Function Interface

Input control target No., default is 1, Maximum 99 targets while using Combination Mode

Page 4: User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View

1. Select Mode to open key mode menu

2. Select key control mode

3. Save

Switc

h Pa

nel

Start Programming

Page 5: User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View

Common Key Control Mode

Single On: Run scene on or lights on every time you pressSingle Off: Off Light or scene, every time you press itSingle On/Off: The classical use of toggling of single press ON/OFFMomentary: To run 1 command as momentary pressingCombination ON: To trigger up to 99 different commands every time the button pressedCombination OFF: To OFF up to 99 commands every time the button pressedCombination ON/OFF: To trigger up to 99 commands toggling between ON/OFF each time the button pressed

Page 6: User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View

Switc

h Pa

nel

1. Select Remark

2. Edit remark

3. Save

Page 7: User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View

1. Select Function to

open key function edit

menu

2. Input device address, type and parameter.Example: the control target is a dimmer module(Subnet ID:0, DeviceID:30) channel 1, channel 2 and channel 3 intensity are both 60%, so first select area 1 and set scene 1 60% intensity, then input Subnet ID : 0 Device ID :30 Type : Scene switch parameter 1 : 1, parameter 2 : 1

3. Save

Switc

h Pa

nel

Page 8: User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View

The Button Function of switch panel is listed down:

Invalid: Is to disable the functionScene Switch: Used to trigger the Scene that you create on the Dimmer or Relay AreaSequence Switch: Used To trigger the Sequence that you create on the Dimmer or relay AreaUniversal Switch: Used to send infrared code number, play show control list , set logic flag On or Off, set the hotel door bell services , disable or enable (Motion sensor, light intensity, zone port automation )Single channel Lights: Used to turn one channel lights on./off with special level and running fade timeCurtain Switch: Used to open, close or stop the curtain channelBroadcast scene: Used to trigger same scene number for all the Areas of the dimmer or relayBroadcast Channel: Used to turn ON/OFF or set channel to brightness level for the all channel of Dimmer or relay