F l o w m e t e r s
Light
User friendly
Highly effective
Accurate
Flow selector device. To be used in any kind of flowmeter with a DISS outlet. With a simple twist you can choose betweenthe humidifier or the hose outlet without having to remove the humidifier.
Single patient use humidifier. Bubble device. Jar made of crystal polysterene and ABS cover. Jar capacity: 285 mL.
Single patient use nebulizer / humidifier.O2 concentration in the supply mixture can be adjusted between 35-100%. Bubble device.Complete cover with two plugs for a quick water recharging. Jar capacity: 450 mL.
Metallic DISS connector for O2 tube.
Plastic DISS connector for O2 tube.
Single patient use O2 face mask. 3210221Adult
Child
Adult
Child
3210220
Single patient use O2 nasal cannula.
Single patient use concentration O2 face mask.
Flowmeters rail coupling system with fitting (fitting to be specified by customer).Please consult.
Single patient use O2 face mask with nebulizer.
4540610
4905400
0520101
0930001
0930013
0520000
0520002
0930005
0930006
Flowmeters with f loat ing bal l Accessories
L/min SS8752430 BS 5682 NF 90 116 DIN 13260
0-15 Rail
0-15 dual
Rail
0-15 selector
Rail
0-15 selector dual
Rail
0-15
Rail
0-15 dual
Rail
0-15 selector
Rail
0-15 selector dual
Rail
5450637
5450001
5450600
54506475450644545064254506415450640
55406465540643554064255406404540606
5450634545063254506315450630
55406565540653554065255406504540605
54503075450304545030254503015450300
55403565540353554035255403504540305
54503175450314545031254503115450310
55403065540303554030255403004540300
54506275450624545062254506215450620
5450607545060454506025450601
54500575450054545005254500515450050
545000754500045450002
55406265540623554062255406204540603
55406065540603554060255406004540600
55400565540053554005255400504540005
5450000
55400065540003554000255400004540000
DISS CHEMETRON OHMEDA PURITAN UNI AFROX
Without fitting
O2
Air
PPyzmmyzmm ®
PPyzmmyzmm ®
Leaflet No.
IN-4540/13/02
HERSILL, S.L.Puerto de Navacerrada, 3 • Polígono Industrial Las Nieves28935 Móstoles (Madrid) SPAINTel.: +34 91 616 60 00 • Fax: +34 91 616 48 [email protected] • [email protected]
QfQfssggmpmpxx ®
P
Standards: EN 13220:1998ISO 15002:2008
Special fittings are available upon request. Please contact Hersill for details
Sterilizable humidifier.With diffuser, sterilizable by autoclave at 121 ºC (250 ºF). Bubble device. Jar made of polycarbonateand polyamide cover. Jar capacity: 350 mL.
Sterilizable humidifier.With diffuser and over-pressure valve, sterilizable by autoclave at 121 ºC (250 ºF). Bubble device.Jar made of polycarbonate and polyamide cover. Jar capacity: 350 mL.
5530000
5530002
Caudalímetros (INGLES):Maquetación 1 27/02/13 20:01 Página 1
F l o w m e t e r s
Light
User friendly
Highly effective
Accurate
Flow selector device. To be used in any kind of flowmeter with a DISS outlet. With a simple twist you can choose betweenthe humidifier or the hose outlet without having to remove the humidifier.
Single patient use humidifier. Bubble device. Jar made of crystal polysterene and ABS cover. Jar capacity: 285 mL.
Single patient use nebulizer / humidifier.O2 concentration in the supply mixture can be adjusted between 35-100%. Bubble device.Complete cover with two plugs for a quick water recharging. Jar capacity: 450 mL.
Metallic DISS connector for O2 tube.
Plastic DISS connector for O2 tube.
Single patient use O2 face mask. 3210221Adult
Child
Adult
Child
3210220
Single patient use O2 nasal cannula.
Single patient use concentration O2 face mask.
Flowmeters rail coupling system with fitting (fitting to be specified by customer).Please consult.
Single patient use O2 face mask with nebulizer.
4540610
4905400
0520101
0930001
0930013
0520000
0520002
0930005
0930006
Flowmeters with f loat ing bal l Accessories
L/min SS8752430 BS 5682 NF 90 116 DIN 13260
0-15 Rail
0-15 dual
Rail
0-15 selector
Rail
0-15 selector dual
Rail
0-15
Rail
0-15 dual
Rail
0-15 selector
Rail
0-15 selector dual
Rail
5450637
5450001
5450600
54506475450644545064254506415450640
55406465540643554064255406404540606
5450634545063254506315450630
55406565540653554065255406504540605
54503075450304545030254503015450300
55403565540353554035255403504540305
54503175450314545031254503115450310
55403065540303554030255403004540300
54506275450624545062254506215450620
5450607545060454506025450601
54500575450054545005254500515450050
545000754500045450002
55406265540623554062255406204540603
55406065540603554060255406004540600
55400565540053554005255400504540005
5450000
55400065540003554000255400004540000
DISS CHEMETRON OHMEDA PURITAN UNI AFROX
Without fitting
O2
Air
PPyzmmyzmm ®
PPyzmmyzmm ®
Leaflet No.
IN-4540/13/02
HERSILL, S.L.Puerto de Navacerrada, 3 • Polígono Industrial Las Nieves28935 Móstoles (Madrid) SPAINTel.: +34 91 616 60 00 • Fax: +34 91 616 48 [email protected] • [email protected]
QfQfssggmpmpxx ®
P
Standards: EN 13220:1998ISO 15002:2008
Special fittings are available upon request. Please contact Hersill for details
Sterilizable humidifier.With diffuser, sterilizable by autoclave at 121 ºC (250 ºF). Bubble device. Jar made of polycarbonateand polyamide cover. Jar capacity: 350 mL.
Sterilizable humidifier.With diffuser and over-pressure valve, sterilizable by autoclave at 121 ºC (250 ºF). Bubble device.Jar made of polycarbonate and polyamide cover. Jar capacity: 350 mL.
5530000
5530002
Caudalímetros (INGLES):Maquetación 1 27/02/13 20:01 Página 1
Technical features
Variable input pressure
3 – 5.5 bar 43 - 80 psi
Fixed input pressure
4 bar
50 psi
!
!QQ66
!QQ55
!
!
!
Click s ty le dia l f lowmeters
Technical features
The flowmeter selector has been designed to save time and O2.It performs a revolving control knob that allows to supply O2
through the direct outlet to the face mask, nebulizer or throughthe humidifier. There is no interruption of O2 supply during thisoperation.
Chromium–plated brass body, inner an outer tube inpolycarbonate, stainless steel float, other parts in brass,polyamide and NBR.
This equipment compensates the variations of pressure of thepipeline since it admits all the pressure of the line, maintainsthe pressure and it provides to the patient the selected flowunder atmospheric pressure, through the mask, nasal catheter,humidifier, etc.
45400004540600
4540600
5530000
0930005
5450000
+
+
PPyzmmyzmm ®
QfQfssggmpmpxx ®
P
!
!
PPyzmmyzmm
!
!
PPyzmmyzmm
!
!
PPyzmmyzmm
!
!
PPyzmmyzmmevbmevbm
Dimensions 145 / 48 mm 155 / 63 mm 145 / 145 mm
Weight 160 g 214 g 570 g
Inlet Whitworth GAS 1/8”
Outlet DISS O2 9/16” - 18 UNF
Pressure 4.2 Kg/cm2 – 60 psi – 414 kPa
L/min 0 - 15
4540000 4540600 4540005
Rail
Special fittings are available upon request: DISS, Chemetron, Ohmeda, Puritan, UNI, AFROX
OX1 0-1 L/min 0 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.5 0.6 0.7 0.8 0.9 1
OX5 0-5 L/min 0 0.1 0.2 0.3 0.4 0.6 0.8 1 1.5 2 2.5 3 4 5
OX15 / AIR15 0-15 L/min 0 0.2 0.4 0.7 1 1.5 2 3 4 6 8 10 12 15
OX50 / AIR50 0-50 L/min** 0 2 4 8 12 16 20 24 28 32 36 40 45 50
* Flows calibrated at STP conditions (23 ºC, 101.3 kPa)** Perflow flowmeter 0-50 L/min is indicated for CPAP
Flow settings*
Perflow P4 Perflow P5 Perflow multy
Dimensions 56 x 37 mm 65 x 38 mm
Weight 98 g 112 g
Inlet Whitworth GAS 1/8”
Outlet DISS O2 9/16”-18 UNF
4540005
Incorporates a pressure stabilizer micro-regulator thatassures the flow accuracy in case of change of the pressuresupply, allowing variations in such input pressure.
!QfQfssggmpmpxx
evbmevbm !
!QfQfssggmpmpxxnvmuz!sbjmnvmuz!sbjm
QfQfssggmpmpxxQ5!bjsQ5!bjs !
L/min SS8752430 BS 5682 NF 90 116 DIN 13260 DISS
P4 OX15
Rail
P4 OX15 dual
Rail
P4 OX50
Rail
P5 OX15
Rail
P5 OX50
Rail
multy OX1
Rail
multy OX5
Rail
multy OX15
Rail
P4 AIR15
Rail
P4 AIR50
Rail
P5 AIR15
Rail
P5 AIR50
Rail
multy AIR15
Rail 54508775450874545077354508715450870
55408775540874554087355408714540870
54508995450895
55408994540895
54508985450890
55408984540890
54508375450834545083354508315450830
55408375540834554083355408314540830
54508275450824545082354508215450820
55408275540824554082355408214540820
54508675450864545086354508615450860
55408675540864554086355408614540860
54508575450854545085354508515450850
55408575540854554085355408514540850
54508475450844545084354508415450840
55408475540844554084355408414540840
54508895450885
55408894540885
54508885540880
55408884540880
54508175450814545081354508115450810
55408175540814554081355408114540810
54528075452804545280354528015452800
55428075542804554280355428014542800
54508075450804545080354508015450800
55408075540804554080355408014540800
Without fitting
QfQfssggmpmpxx ®
O2
Air
High precision flowmeters with calibrated orifices, a long diameter and great visibility. Control knob with click style positions, makesit more comfortable to use and safer against accidental flow changes.
Aluminium body, polycarbonate dial, DISS outlet in chromium-plated brass, rest in stainless steel, NBR, silicone and polyamide.
Require fixed and stable input pressure.QfQfssggmpmpxx!QQ55
!
!
QfQfssggmpmpxx!QQ66
!
!
Caudalímetros (INGLES):Maquetación 1 27/02/13 20:01 Página 2
40 - 100 2.8 - 7
Technical features
Variable input pressure
3 – 5.5 bar 43 - 80 psi
Fixed input pressure
4 bar
50 psi
!
!QQ66
!QQ55
!
!
!
Click s ty le dia l f lowmeters
Technical features
The flowmeter selector has been designed to save time and O2.It performs a revolving control knob that allows to supply O2
through the direct outlet to the face mask, nebulizer or throughthe humidifier. There is no interruption of O2 supply during thisoperation.
Chromium–plated brass body, inner an outer tube inpolycarbonate, stainless steel float, other parts in brass,polyamide and NBR.
This equipment compensates the variations of pressure of thepipeline since it admits all the pressure of the line, maintainsthe pressure and it provides to the patient the selected flowunder atmospheric pressure, through the mask, nasal catheter,humidifier, etc.
45400004540600
4540600
5530000
0930005
5450000
+
+
PPyzmmyzmm ®
QfQfssggmpmpxx ®
P
!
!
PPyzmmyzmm
!
!
PPyzmmyzmm
!
!
PPyzmmyzmm
!
!
PPyzmmyzmmevbmevbm
Dimensions 145 / 48 mm 155 / 63 mm 145 / 145 mm
Weight 160 g 214 g 570 g
Inlet Whitworth GAS 1/8”
Outlet DISS O2 9/16” - 18 UNF
Pressure 4.2 Kg/cm2 – 60 psi – 414 kPa
L/min 0 - 15
4540000 4540600 4540005
Rail
Special fittings are available upon request: DISS, Chemetron, Ohmeda, Puritan, UNI, AFROX
OX1 0-1 L/min 0 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.5 0.6 0.7 0.8 0.9 1
OX5 0-5 L/min 0 0.1 0.2 0.3 0.4 0.6 0.8 1 1.5 2 2.5 3 4 5
OX15 / AIR15 0-15 L/min 0 0.2 0.4 0.7 1 1.5 2 3 4 6 8 10 12 15
OX50 / AIR50 0-50 L/min** 0 2 4 8 12 16 20 24 28 32 36 40 45 50
* Flows calibrated at STP conditions (23 ºC, 101.3 kPa)** Perflow flowmeter 0-50 L/min is indicated for CPAP
Flow settings*
Perflow P4 Perflow P5 Perflow multy
Dimensions 56 x 37 mm 65 x 38 mm
Weight 98 g 112 g
Inlet Whitworth GAS 1/8”
Outlet DISS O2 9/16”-18 UNF
4540005
Incorporates a pressure stabilizer micro-regulator thatassures the flow accuracy in case of change of the pressuresupply, allowing variations in such input pressure.
!QfQfssggmpmpxx
evbmevbm !
!QfQfssggmpmpxxnvmuz!sbjmnvmuz!sbjm
QfQfssggmpmpxxQ5!bjsQ5!bjs !
L/min SS8752430 BS 5682 NF 90 116 DIN 13260 DISS
P4 OX15
Rail
P4 OX15 dual
Rail
P4 OX50
Rail
P5 OX15
Rail
P5 OX50
Rail
multy OX1
Rail
multy OX5
Rail
multy OX15
Rail
P4 AIR15
Rail
P4 AIR50
Rail
P5 AIR15
Rail
P5 AIR50
Rail
multy AIR15
Rail 54508775450874545077354508715450870
55408775540874554087355408714540870
54508995450895
55408994540895
54508985450890
55408984540890
54508375450834545083354508315450830
55408375540834554083355408314540830
54508275450824545082354508215450820
55408275540824554082355408214540820
54508675450864545086354508615450860
55408675540864554086355408614540860
54508575450854545085354508515450850
55408575540854554085355408514540850
54508475450844545084354508415450840
55408475540844554084355408414540840
54508895450885
55408894540885
54508885540880
55408884540880
54508175450814545081354508115450810
55408175540814554081355408114540810
54528075452804545280354528015452800
55428075542804554280355428014542800
54508075450804545080354508015450800
55408075540804554080355408014540800
Without fitting
QfQfssggmpmpxx ®
O2
Air
High precision flowmeters with calibrated orifices, a long diameter and great visibility. Control knob with click style positions, makesit more comfortable to use and safer against accidental flow changes.
Aluminium body, polycarbonate dial, DISS outlet in chromium-plated brass, rest in stainless steel, NBR, silicone and polyamide.
Require fixed and stable input pressure.QfQfssggmpmpxx!QQ55
!
!
QfQfssggmpmpxx!QQ66
!
!
Caudalímetros (INGLES):Maquetación 1 27/02/13 20:01 Página 2
F l o w m e t e r s
Light
User friendly
Highly effective
Accurate
Flow selector device. To be used in any kind of flowmeter with a DISS outlet. With a simple twist you can choose betweenthe humidifier or the hose outlet without having to remove the humidifier.
Single patient use humidifier. Bubble device. Jar made of crystal polysterene and ABS cover. Jar capacity: 285 mL.
Single patient use nebulizer / humidifier.O2 concentration in the supply mixture can be adjusted between 35-100%. Bubble device.Complete cover with two plugs for a quick water recharging. Jar capacity: 450 mL.
Metallic DISS connector for O2 tube.
Plastic DISS connector for O2 tube.
Single patient use O2 face mask. 3210221Adult
Child
Adult
Child
3210220
Single patient use O2 nasal cannula.
Single patient use concentration O2 face mask.
Flowmeters rail coupling system with fitting (fitting to be specified by customer).Please consult.
Single patient use O2 face mask with nebulizer.
4540610
4905400
0520101
0930001
0930013
0520000
0520002
0930005
0930006
Flowmeters with f loat ing bal l Accessories
L/min SS8752430 BS 5682 NF 90 116 DIN 13260
0-15 Rail
0-15 dual
Rail
0-15 selector
Rail
0-15 selector dual
Rail
0-15
Rail
0-15 dual
Rail
0-15 selector
Rail
0-15 selector dual
Rail
5450637
5450001
5450600
54506475450644545064254506415450640
55406465540643554064255406404540606
5450634545063254506315450630
55406565540653554065255406504540605
54503075450304545030254503015450300
55403565540353554035255403504540305
54503175450314545031254503115450310
55403065540303554030255403004540300
54506275450624545062254506215450620
5450607545060454506025450601
54500575450054545005254500515450050
545000754500045450002
55406265540623554062255406204540603
55406065540603554060255406004540600
55400565540053554005255400504540005
5450000
55400065540003554000255400004540000
DISS CHEMETRON OHMEDA PURITAN UNI AFROX
Without fitting
O2
Air
PPyzmmyzmm ®
PPyzmmyzmm ®
Leaflet No.
IN-4540/13/02
HERSILL, S.L.Puerto de Navacerrada, 3 • Polígono Industrial Las Nieves28935 Móstoles (Madrid) SPAINTel.: +34 91 616 60 00 • Fax: +34 91 616 48 [email protected] • [email protected]
QfQfssggmpmpxx ®
P
Standards: EN 13220:1998ISO 15002:2008
Special fittings are available upon request. Please contact Hersill for details
Sterilizable humidifier.With diffuser, sterilizable by autoclave at 121 ºC (250 ºF). Bubble device. Jar made of polycarbonateand polyamide cover. Jar capacity: 350 mL.
Sterilizable humidifier.With diffuser and over-pressure valve, sterilizable by autoclave at 121 ºC (250 ºF). Bubble device.Jar made of polycarbonate and polyamide cover. Jar capacity: 350 mL.
5530000
5530002
Caudalímetros (INGLES):Maquetación 1 27/02/13 20:01 Página 1