Use the Page Down button on your keyboard or these blue buttons to step through the presentation. System Overview

Use the Page Down button on your keyboard or these blue buttons to step through

  • Upload
    emory

  • View
    34

  • Download
    0

Embed Size (px)

DESCRIPTION

System Overview. Use the Page Down button on your keyboard or these blue buttons to step through the presentation. System Overview. Patient Management Recording Analysis Reporting. Patient Management. - PowerPoint PPT Presentation

Citation preview

Page 1: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Use the Page Down button on your keyboard or these blue buttons to step through the presentation.

System Overview

Page 2: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

System Overview

• Patient Management• Recording• Analysis• Reporting

Page 3: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Patient Management

Page 4: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

When Cognitrace starts the patient management database is opened automatically. From here you can manage patients, review recordings, analyze data and build reports.

The patient management database includes tools for searching through records and archiving data to CD or DVD. Intuitive icons let you navigate the data.

Page 5: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The top pane shows Patients. The table can be sorted on each of the fields, i.e. last name, first name, patient ID etc. Search forms are available to quickly find patients.

Patient information is not restricted to the above shown fields, information related to medication, diagnosis, address information or other text fields can be included as well.

Page 6: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The middle pane shows the Recordings for the selected patient. The table can be sorted on each of the fields, i.e. date of recording, type of recording, name of technician etc.

Search forms are available to quickly find those recordings that were done in the previous week, months etc.

Page 7: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The lower pane shows Studies. Studies are all the analysis results and reports that were generated for a certain recording. The table can be sorted on each of the fields, i.e. type of analysis, finished yes/no, notes etc.

Search forms are available to locate all studies that were not finished yet.

Page 8: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

By clicking the Control pane button a small window appears on the left of the screen that allows the user to search the patient database (so-called queries) and to perform archiving.

Page 9: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Control Pane: Performing queries using filters

Patients, Recordings and Studies can be filtered in order to select a subset of them.

(for instance, the letter b can be entered in the Patient field, which selects from the list of patients only those of whom the last name starts with b)

Unfinished studies and recent recordings can be selected quickly for review and archiving.

Page 10: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Control Pane: Archiving

Archiving of data is accomplished by selecting the Archive tab in the control pane. Here you can export data that you selected via a filter to CD, DVD, HD or local network.

Cognitrace archives all data that was selected by the data filter. Archiving is done within cognitrace and the progress tab shows the completion of the process.

Page 11: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Via this check box it is also possible to define which data will be archived.

Page 12: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Control Pane: Import / View

Data can be imported into the patient database by selecting the Import option. With View a temporary database is generated that allows the technician to review data without having to import the data completely.

Page 13: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Clicking the New or Edit patient buttons allows the user to enter new patient information.

Page 14: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

New Patient Form Edit patient information form

Patient information is not restricted to the shown fields,information related to medi-cation, diagnosis, address or other text fields can be included as well.

Page 15: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Recording

Page 16: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

New recordings are started by clicking the New recording button and by selecting one of the templates from the new recording dialogue.

The recording is automatically initialized and opens a new window.

Page 17: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

New recording dialogue:The drop down list next to templates allows selection of different recording templates (protocols). Notes can be added to facilitate data identification on later occasion.

Page 18: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

After clicking the check mark of the new recording dialogue a connection to the amplifier is made and the program starts showing the data as it comes in. Data is not stored at this moment.

Page 19: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The panel on the lower left shows the protocol of the recording. It includes different steps such as patient preparation (impedance check) and different stimulation sessions. A red dot next to a step indicates that it is mandatory. Steps without it can be skipped.

Page 20: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The upper left panel shows information for each of the steps in the protocol and guides the user through the recording protocol.

Clicking >> and << allows the user to step forward and backward in the protocol.

Page 21: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

First thing to do is to check impedance and make sure each electrode makes a good connection to the scalp. Impedances should be lower than 50k Ohm for high-quality recordings.

By clicking the Impedance check button the program automatically switches to impedance view.

Page 22: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Impedance view

A colour at each electrode defines the level of impedance, blue being a good, red being a poor connection to the scalp.

All channels are shown in head layout to allow easy navigation on the cap.

Page 23: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

After the impedance has been checked the user switches back to EEG preview. The quality of the EEG can be checked visually. The user can always return to Impedance check to access the impedances. Impedance values are stored at the beginning in the raw data and can be reviewed off line.

Page 24: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The user should click >> to continue with the protocol of recording.

Page 25: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The next step in this protocol consists of recording sessions of continuous EEG with eyes closed, eyes open and hyperventilation.

The following slides explain all the sessions in this recording protocol in more detail.

Page 26: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Eyes closed

During the eyes closed session continuous EEG is recorded and markers are placed in the EEG to denote the type of session and the number of the run (EC_1 = First Eyes Closed run).

The Start Eyes Closed button starts the recording, Pause allows the technician to pause the recording, Stop Eyes Closed terminates this session and allows the user to continue with the next.

The timer starts counting automatically when the session is started and keeps track of the total session time so far.

Data is epoched in 2s intervals for the spectral analysis processing after the recording.

EC_1 EC_1 EC_1 EC_1 EC_1 EC_1 EC_1

2s epochs

Page 27: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

EO_1 EO_1 EO_1 EO_1 EO_1 EO_1 EO_1

2s epochs

Eyes open

During the eyes open session continuous EEG is recorded and markers are placed in the EEG to denote the type of session and the number of the run (EO_1 = First Eyes Open run).

The Start Eyes Open button starts the recording, Pause allows the technician to pause the recording, Stop Eyes Open terminates this session and allows the user to continue with the next.

The timer starts counting automatically when the session is started and keeps track of the total session time so far.

Data is epoched in 2s intervals for the spectral analysis processing after the recording.

Page 28: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Visual Evoked Potential (VEP)

Recording of the brain responseduring stimulation with a photic flash.

Start, Stop and Pause buttons are available to control the recording of the VEP’s.

Again multiple runs can be recorded and make it possible to switch between different types of recording sessions (i.e. between VEP and AEP etc).

VEP_1

1s ISI

VEP_1 VEP_1 VEP_1 VEP_1 VEP_1 VEP_1

Page 29: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Auditory Evoked Potential (AEP)

Recording of brain responses evoked by 1000 Hz tones that are presented at 1 second interval.

Start, Stop and Pause buttons are available to control the recording of the AEP’s.

Again multiple runs can be recorded and make it possible to switch between different types of recording sessions (i.e. between AEP and VEP etc).

AEP_1

1 seconds ISI

AEP_1 AEP_1 AEP_1 AEP_1 AEP_1 AEP_1

Page 30: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Auditory Oddball Paradigm (P300 auditory)

Recording of brain responses to the stimulation of two different tones; a frequent (1000Hz) and rare (2000Hz) one. These tones are presented pseudo-random with a 80/20 likelihood ratio.

Start, Stop and Pause buttons are available to control the recording. The timer keeps track of the recording time in this run.

Multiple runs of P3 can be recorded and make it possible to switch between different types of recording sessions.

freq_1

1 seconds ISI

freq_1 rare_1 freq_1 rare_1 freq_1 freq_1

Page 31: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

AnalysisAuditory Evoked Potential

Page 32: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

AnalysisAnalysis of a recording is started by selecting a recording and then clicking the New button below Studies.

Page 33: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The preferred template for analysis can be selected from a drop-down list and the check mark button is clicked to start the analysis.

Page 34: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The analysis template is opened and some pre-processing steps (like filtering and artefact detection) are performed automatically.

Page 35: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Once these pre-processing steps are finished (takes about 5s), the data and the protocol of analysis is presented.

Page 36: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

AEP_1 events

Event List

Detectedartefacts in pink

Page 37: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Artefacts that were missed by the automatic detection algorithm can be added manually by clicking the artefact event button. The artefact will then be marked and excluded from the rest of the analysis.

Page 38: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Events and Channels can also be selected easily by dragging the mouse over the corresponding EEG event or channel.

The corresponding event is automatically highlighted in the event list to allow the user to enable (check mark) or disable (cross) it.

Page 39: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Once the data is reviewed and artefacts are marked, >> should be clicked. Data is averaged and presented.

Page 40: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The averages are shown in maps and as traces. The blue, black and red traces correspond to three runs of AEP that were collected. At this stage the users can decide which of the runs should be included in the grand average.

Page 41: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Presentation of the grand average.

Page 42: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Age-matched reference data is loaded and presented together with the patient AEP traces. The maps on the right show the AEP maps together with statistical difference (based on z-score) at a certain latency.

Patient

Reference data

z-score

Page 43: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

After reviewing of the statistical maps the report is automatically generated and shows all the snapshots that could be taken during the analysis steps.Extra comments can be added. The report is stored automatically in the database and can be opened on later occasions.

Page 44: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

AnalysisSpectral analysis of Eyes Closed EEG

Page 45: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

The spectral analysis of continuous EEG from eyes closed and eyes open sessions, works similar to the AEP analysis. First, in a pre-processing phase filtering and artefact detection is done, followed by a stage where the user is able to manually review the data.Again, snapshots can be taken from the data and included in the report.

Page 46: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

After review of data, for each 2s epoch the FFT spectra are calculated and an average across these FFT spectra is made. The result is presented with a spectrum for each of the channels.

The colours in the spectra mark the different frequency bands that were configured by the user.

Page 47: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Age-matched reference data is loaded and presented together with the FFT maps of the patient. Statistical maps are shown as well.

Patient

Reference data

z-score

Frequency Bands (theta, delta, alpha, beta)

Page 48: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Patient Reference data

z-score

FFT maps for one frequency band (alpha).

Page 49: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

In the report of spectral analysis comments can be entered. The report can be printed and is saved in the patient database.

Page 50: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Optional recording protocols

Page 51: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Visual Oddball Paradigm (P300 visual)

Similar to the auditory oddball stimulation but instead of tones, two different images are presented. Again, one image is present more frequent than the other (pseudo-random with a 80/20 likelihood ratio):

Start, Stop and Pause buttons are available to control the recording. The timer keeps track of the recording time in this run. Multiple runs can be recorded.

freq_1

1s - 1.1s ISI

freq_1 rare_1 freq_1 rare_1 freq_1 freq_1

FREQUENT

RARE

Picture duration = 250ms

Page 52: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Contingent Negative Variation (CNV) Paradigm

Recording of the brain response to a warned reaction time task.

Warning stimulus (WS): tone of 1000HzImperative stimulus (CNV_1) : flash

“Active” task instruction: turn flash off by button press.

850ms ISI 7.5s to 10.5s ITI

WS CNV_1 WS CNV_1

Tone duration = 60msFlash duration = maximally 1000ms

Page 53: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

P50 Pair-wise tones Paradigm

Recording of very early brain response to presentation of short tones presented in pairs.

Tones: 1000Hz

“Passive” task no response required to task stimuli.

S_1

3200ms ITI

S_2 S_1 S_2 S_1 S_2

300ms ISI

Tone duration = 6ms

Page 54: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

freq_1

500ms ISI

freq_1 rare_1 freq_1 rare_1 freq_1 freq_1

Tone duration = 60ms

Mismatch Negativity Paradigm (Frequency)

Recording of brain response to the stimulation of two different tones; a frequent and a rare tone varying in frequency.

Frequent (freq_1): 1000HzRare (rare_1): 1200Hz

Presented pseudo-randomly with a 10/90 likelihood ratio.

“Passive” task no response required to task stimuli.

Page 55: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

freq_1

500ms ISI

freq_1 rare_1 freq_1 rare_1 freq_1 freq_1

Frequent tone duration = 50msRare tone duration = 100ms

Mismatch Negativity Paradigm (Duration)

Recording of brain response to the stimulation of two different tones; a frequent and a rare tone varying in duration.

Frequent (freq_1): 1000Hz Rare (rare_1): 1000Hz Different Duration!!

Presented pseudo-randomly with a 10/90 likelihood ratio.

“Passive” task no response required to task stimuli.

Page 56: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Somatosensory Evoked Potential (SEP)

Recording of brain response evoked by electrical pulses with a default strength of 6000 and a length of 200 ms at approx. 0,5 sec interval.

Start, Stop and Pause buttons are available to control the recording of the SEP’s.

You can also do a test run containing 10 pulses.

Page 57: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Classic EEG recording

During this protocol continuous EEG is recorded while eyes closed and eyes open, hyperventilation and photic stimulation sessions are performed.

With Start Writing to File the EEG recording is started.

With Start and Stop the hyperventilation and photic stimulation sessions can be started and marked in the EEG.

The timer keeps track of the hyperventilation time so far.

With placing Annotations the eyes closed and eyes open sessions can be marked in the EEG.

Page 58: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Thank you for your interest.

Page 59: Use the  Page Down  button  on your keyboard or these  blue buttons to step through

Visit our website for more information