Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
2
Explosion venting for sterile applications
Multi-layer panels forpressure and vacuum protection
Explosion venting with special requirements
Easy venting withsingle layer panels
Flameless venting
Isolationof pipelines / Decoupling
Explosionsuppression
REMBE®, Inc. with its premises in Charlotte, N.C. was established in 2006 in order to serve customers in U.S.A.,Canada and Mexico on-site. Representatives in several federal states of the U.S.A. provide the customers in all industries consultation, engineering, design and sales ofREMBE® premium pressure and explosion safety systems.
The products of the Safety Division cover both standardand customized components by utilizing the latest laser,welding and precision tool production technologies.
Extensive material stocks provide the foundation for flexible production and fast response deliveries in mostmaterial grades - Stainless Steel, Inconel, Hastelloy, Monel,Aluminium, Tantalum, Titanium, Gold, FEP, etc. Premiumdeliveries can be negotiated on a case by case basis.
REMBE® products are manufactured in accordance withNational and International Certifications, Standards andNorms, i.e. NFPA, ASME VIII, ATEX, DIN-EN ISO 4126-2,-4126-6, AD2000-Merkblatt A1, PED, Promatomnadzor,GOST-R, GOST-K, CML, API, BS2915, KTA.
Whatever the industry: Oil & Gas, Petrochemical, Chemical, Pharmaceutical, Biotech, Food & Beverage,Power, Pulp & Paper and many others; REMBE® have long established referenced experience which is supported by our long serving team of in-house degreed engineers.
REMBE® GMBH SAFETY + CONTROL
headquarter and factory at Brilon / Germany
ABOUT US…
3
Additional information about defined functions and benefits
ERO Sterile explosion venting inrectangular up to 2 m2 (21.5 sqft)venting area
100 % efficiencyfor food and asepticapplications (FDA-approved)USDA compliant
ODUODV
High performanceexplosion venting in round from DN 25 - 2000, (1" - 80"),rectangular up to2 m2 (21.5 sqft) venting area
maintenance-freeperfect opening characteristicslongest lifetimefunction dispersion of burst element and vacuum support layer
EDP
EX-GO-VENT
Controlled explosion ventingin rectangular design
Explosion venting in round-, rectangular- and individual design
domed, ultra stable
flexible, bionic structure
Q-Rohr®-3
Q-Box II
Indoor explosion ventingwith flame absorber and dust retainer
Explosion venting with flame absorber
no vent ductsno access to outsidepassive systemmaintenance-free pressure and noiseabsorbing
EXKOP® IIEXKOP® MINI
Q-Flap / Q-Flap Plus
Quench valve with electronic controllerDN 80 - 600 (3"-24")
Non-return explosion valve
fast installationself-monitoringfail-safeeasy and quick maintenancepassive system
Q-Bic Isolation of big pipesby means of dry powder
Suppression in large scale equipment
safe interlockredundant sensor
INTELLIGENT PREVENTION OF EXPLOSION DAMAGES WITH…
5
6
7
8910111213
1415
16
E x - S t o c kCHARLOTTE
E x - S t o c kCHARLOTTE
E x - S t o c kCHARLOTTE
4
An explosion is defined as 'A rapidincrease in volume and release ofenergy in an extreme manner’, usuallyaccompanied with the generation ofhigh temperatures and the release ofgases. An explosion creates at shockwave'.
Most common reactions are offlammable gases, vapors and crackeddusts - together with ambient oxygen.As a result of modern production tech-nologies and increased production ca-pacities, an explosion is a threatcompanies confront daily. Manufactu-ring processes which create organic orchemical dust caused by faster machi-nes, automatic conveying systems andair cleaning equipment increase therisk of a dust explosion. The finer thedust particle, the more severe the ex-plosion will be.
International guidelines includingNFPA 68, 69, ATEX 95 (Valid for manu-facturers of machines and plants) or
ATEX 137 (valid for operating compa-nies) require companies to consider theconsequences of a dust explosion to in-jured workers and damaged produc-tion plants.
Additionally, the economic risk tothe company due to plant shutdown,contaminated product or adverse pu-blicity requires consideration.
Special attention is required when eli-minating all possible potential sources ofignition such as; Mechanical or Electricallyproduced 'sparks', Frictional heat, Electro-static charges (See note* below), Weldingequipment etc. Not forgetting of course,the human factor. Due to the seeminglyendless sources for potential ignitions it isnot hard to imagine the difficulty in elimi-nating them all. Removal of the fuel is im-
possible as this is what is being producedby the process in the plant that we are con-sidering protecting. Removal of Oxygen isfeasible but can only be achieved throughvary expensive processing. The security li-mits here are also rapidly reached and therisk of a dust explosion cannot be excluded.Therefore a constructive and efficient ex-plosion protection regime is required andessential.
THREE BASIC REQUIREMENTS HAVETO BE CONSIDERED IN A MODERNEXPLOSION PROTECTION SOLU-TION:
1. PROFITABILITYThe protection solution has to be economical to implement, operate and maintain.
2. RELIABILITYThe protected facility has to remainpermanently and optimally avai-lable for production. A break in daily operations, due to false triggering, must be avoided.
3. SAFETYPeople and machine must be insured of an explosion protected environment, through constructiveand effective directives.
ALL OF THESE REQUIREMENTS ARE MET BY REMBE®
EXPLOSION SAFETY SYSTEMS.
Primary Explosion Protection Provides only a Limited Safety
Enormous Economic Damage…
NOTE* Contact KERSTING GMBH SAMPLING + GROUNDING, a REMBE® ALLIANCE company and refer to 'Grounding Systems'.
Working condition Application
Standard Burst Pressure[psig @ 72 °F] /[mbar @ 22 °C]
LowestPossibleBurst
Tolerance (in %)
Design Type
1.45 / 100 15 single-layer ERO
1.45 / 100 10triple-section
ODU
1.45 / 100 10triple-section
ODV
1.45 / 100 15 single-layer EDP
1.45 / 100 15 single-layer EX-GO-VENT
5
Silo protection with ERO panels in the food industry
EXPLOSION PANELS OVERVIEW
Why choose REMBE®?
REMBE® offer optimal explosion panelconstructions for all applications andworking conditions. For use in corrosiveatmosphere or in case of extreme workingconditions, e.g.; frequent changing, pulsa-ting or vacuum pressure; REMBE® offerthe applicable explosion panel.
REMBE® Rupture Panels distinguish themselves by extremely precise rupturepressures, guaranteeing 100% efficiency,enabling the user to save space andmoney by optimizing the installed venting area.
REMBE® Rupture Panels are non-frag-menting and have ideal opening characteristics which leads to lower reduced pressure (Pred).
Transfer the many benefits of REMBE®
Rupture Panels into substantial savings oftime and money resulting in increasedprofitability.
ERO Sanitary Rupture Panels are manufac-tured for utilization in Food & Beverageand Pharmaceutical processing equipmentthat has to be protected against pressureas well as dynamic explosion pressure rise.The process is sealed by the completesmooth and homogenous stainless steelmembrane of the ERO. The patented de-sign (Pat.-No. EP 07 73 393) allows robustconstruction in combination with low response pressures.
ERO Pat.-No. EP 07 73 393
Silo Filter Sanitary
FSA 04 ATEX 1538 X
qualified partly qualified unqualified
p = pressuret = time
The REMBE® ERO is the only sanitary Explosion Panel with
USDA approval.
6
Wood chip plant protected by ODVs
EXPLOSION VENTING WITH TRIPLE-SECTIONRUPTURE DISCS/PANELS
The domed triple section rupture discs/pa-nels developed by REMBE® have a provenpedigree and have been successfully pro-tecting a variety of industrial plants formore than 37 years, distinguishing them-selves by their sturdy construction and re-liability.
The triple section ODV Rupture Disc/Panelis mainly used for applications with low ormiddle burst pressures. The burst pressureis determined by the burst element withintegrated breaking points and its sealingpart. Breaking points are made by CNCcontrolled laser micro-cutting machines.This enables the highest possible precisionthereby guaranteeing the required burstpressure within tolerance.
ODV's are applied to working pressuresup to 80% of the specified burst pressure(80% operating ratio).
ODU / ODV
FSA 04 ATEX 1538 X
DN / NPS / rupture values ofround triple-section rupture discs:
All dimensions are nominal* Valid for ODV only
Higher vacuum resistance on request
DN NPSEff.
VentingArea
Eff. VentingArea
Min. RupturePressure
Min. RupturePressure
VacuumResis-tance*
mm inch cm2 sq inch barg psig mm WC
50 2" 17 2.60.8 11.60
absolute
65 2,5" 25 3.8
80 3" 35 5.4 0.6 8.70
100 4" 60 9.30.3 4.35
125 5" 80 12.4
150 6" 125 19.4 0.2 2.90
200 8" 245 38.0
0.1 1.45250 10" 400 62.0
300 12" 600 93.0
350 14" 750 116.2
400 16" 1000 155.0
0.05 0.73
450 18" 1430 221.6
500 20" 1660 257.3
550 22" 2150 333.2
600 24" 2500 387.5
700 28" 3500 542.5 5000
750 30" 4200 651.03000
800 32" 4600 713.0
900 36" 5900 914.51000
1000 40" 7400 1147
0.025 0.36
1100 44" 8950 1387
5001200 48" 10000 1550
1250 50" 11700 1813
1300 52" 12500 1937100
1400 56" 15000 2325
DN / NPS / rupture values of rectan-gular triple-section rupture discs:
All dimensions are nominal* Valid for ODV only
Higher vacuum resistance on request
ventingsize
ventingsize
Eff.VentingArea
Eff. VentingArea
Min. RupturePressure
Min. RupturePressure
VacuumResis-tance*
mm inch cm2 sq inch barg psig mm WC
130 x 500 5.1 x 19.7 500 77.5
0.1 1.45
2000229 x 305 9.0 x 12.0 540 83.7
150 x 600 5.9 x 23.6 720 111.6
305 x 305 12.0 x 12.0 785 121.7
205 x 610 8.1 x 24.0 1000 155.0
1000
270 x 465 10.6 x 18.3 1000 155.0
340 x 385 13.4 x 15.2 1100 170.5
0.05 0.73
314 x 424 12.4 x 16.7 1150 178.3
345 x 405 13.6 x 15.94 1150 178.3
305 x 457 12.0 x 18.0 1200 186.0
247 x 610 9.7 x 24.0 1300 201.5
340 x 440 13.4 x 17.3 1300 201.5
400 x 400 15.7 x 15.7 1400 217,0
410 x 410 16.1 x 16.1 1450 224.8
404 x 420 15.9 x 16.5 1500 232.5
305 x 610 12.0 x 24.0 1600 248.0
354 x 580 13.9 x 22.8 1800 279.0
440 x 605 17.3 x 23.8 2400 372.0
0.035 0.51
800490 x 590 19.3 x 23.2 2600 403.0
470 x 610 18.5 x 24.0 2600 403.0
500 x 620 19.7 x 24.4 2800 434.0
386 x 920 15.2 x 36.2 2900 449.5
500
570 x 620 22.4 x 24.4 3200 496.0
590 x 620 23.2 x 24.4 3300 511.5
600 x 600 23.6 x 23.6 3300 511.5
605 x 605 23.8 x 23.8 3350 519.3
610 x 610 24.0 x 24.0 3400 527.0
575 x 645 22.6 x 25.4 3400 527.0
620 x 620 24.4 x 24.4 3500 542.5
457 x 890 18.0 x 35.0 3700 573.5
653 x 653 25.7 x 25.7 3900 604.5
600 x 800 23.6 x 31.5 4400 682.0
0.025 0.36
300
710 x 710 28.0 x 28.0 4700 728.5
620 x 820 24.4 x 32.3 4750 736.3
586 x 920 23.1 x 36.2 5000 775.0
750 x 840 29.5 x 33.1 5900 914.5
800 x 800 31.5 x 31.5 6000 930.0
457 x 1500 18.0 x 59.1 6200 961.0
610 x 1118 24.0 x 44.0 6400 992.0
645 x 1130 25.4 x 44.5 6800 1054
840 x 920 33.1 x 36.2 7300 1131
920 x 920 36.2 x 36.2 8000 1240
457 x 2000 18.0 x 78.7 8400 1302
200
586 x 1630 23.1 x 64.2 8900 1379
1000 x 1000 39.4 x 39.4 9500 1472
915 x 1118 36.0 x 44.0 9700 1503
1020 x 1020 40.2 x 40.2 9900 1534
586 x 1893 23.1 x 74.5 10400 1612
100920 x 1254 36.2 x 49.4 11000 1705
740 x 1630 29.1 x 64.2 11300 1751
740 x 1893 29.1 x 74.5 13200 2046
50750 x 1900 29.5 x 74.8 13400 2077
920 x 1920 36.2 x 75.6 17000 2635
7
EX-GO-VENT panels - filter system: Holtrop & Jansma, NL
Silo with EDP rupture panels in the wood-processing industry
SINGLE LAYER EXPLOSION VENTS
EDP
EX-GO-VENT
EX-GO-VENT rectangular- and trapezium panel
EDP single-layer rupture panel – provides easy and quick mounting
The Single Layer EDP explosion panel is recommended for protection against fluctuating or cyclic working pressures.The Domed construction provides highstability up to a pressure ratio of 80%.The rated breaking points (Pat. No. EP 0773 393) are integrated within the moun-ting frame. The Domed construction alsogreatly reduces contamination. Sterilityand cleaning is simplified (SIP/CIPCleaning).
Usually the EDP is mounted directly onto aWall. Installation of the EDP Vent Frame isuncomplicated and is NOT torque depen-dent.
The EX-GO-VENT incorporating bionicstructures guarantees an extraordinarystability in order to suit most standard applications.
Unlike other manufacturers options theEX-GO-VENT is NOT torque dependent during installation. Typically, mounting is directly made onto even walls or round-shaped equipment, e.g.; cyclones, filters,silos, etc.
8
INDOOR EXPLOSION VENTING…
Q-Rohr®-3 Pat.-No. DE 38 22 012U.S. Patent pending
1 2 3
Thermo graphic recording of a dust explosion venting controlled with rupture disc
Conventional explosion venting with a rupture disc
The Q-Rohr®-3 explosion protection system is a provenreliable product designed and engineered follow-
ing extensive research and development culmi-nating in the most innovative and efficient flame-less venting product on the world market today.
The consistent demand from our customers is theneed for a protection system where the flame and dust
distribution can be limited to a point where the systemcan be kept indoors. The Q-Rohr®-3 has been designed
with customer driven criteria such as; zero maintenance, un-limited life-span, huge reduction in the generated temperatu-
res and effective dust retention. The Q-Rohr®-3 has been provento meet all of these demands. In a thermo graphical investigation
of a dust explosion, it has been recorded that when using a Q-Rohr®-3 there is a huge reduction in temperatures generated.
…PROTECTS AGAINST POTENTIAL CATASTROPHIC DAMAGE
Only the original construction of the
Q-Rohr®-3guarantees the full effectiveness in the event of a dust explosion. Copies and imitations present an unnecessary safety risk.
SAFETY ADVICE
2,732° F
572° F
68° F32° F
9
The REMBE® Q-Rohr®-3: The latest gene-ration of Indoor explosion vents from the inventors of ‘flameless venting’ guarantees indoor venting WITHOUT any flame and dust propagation. Further,the Q-Rohr®-3, ATEX- and FM approved ismaintenance free, negating operationalcosts and thereby offering the most eco-nomical solution while ensuring optimumprocesses maintaining efficient produc-tion.
After investing in the Q-Rohr®-3, a ROIwill be noticed within only a few weeks.
Q-Rohr®-3
…WITH FLAME ABSORBERAND DUST RETAINER
Your benefits at a glance
no further necessity ofexpensive vent ducts
full protection of environment
optimized production processes
no access to outside
Advice
IBExU04ATEX2028 X
Pat.-No. DE 38 22 012U.S. Patent pending
Certified by:
No heat development outside the Q-Rohr®-3, that means only a very lowpressure and minimal noise
1 2 3
Stainless steel riveted design allows to absorb pressure shock
Reusable flame arrester made of a special stainless steel mesh filter
Stainless steel dust filter with specially developed pressure absorbing coils
Integrated REMBE® rupture disc with signal unit and gasket
Monitoring unit in cabled IP-65 housing
Q-Rohr®-3in sizes8" to 32"
An identical situation, this time using a Q-Rohr®-3, therefore no flames or dust
2,732° F
572° F
68° F32° F
10
PROVEN SAFETY FOR EQUIPMENT IN ANY LOCATION
Q-Rohr®-3 Pat.-No. DE 38 22 012U.S. Patent pending
After cleaning the flame arrester and exchanging the rupture disc, the Q-Rohr is ready for use again.
An optional fireproof cover keeps theoutside clean.
The Q-Rohr®-3 system is the only indoorexplosion device recognized worldwide byNFPA68 and accepted also by VDI-3673and prEN 14797. It consists of an integra-ted REMBE® rupture disc which vents theexplosion wave in a controlled mannerwithin the Q-Rohr®-3 assembly. Flamegases with temperatures higher than2,732 °F are cooled down to less than 195 °F via energy transfer within the specially developed stainless steel meshfilter inlet. This reduces the expanding gasvolume as it extinguishes the flame. Dustretention is guaranteed by the mesh filterensuring that no burnt or unburnt dustparticles pass through the Q-Rohr®-3 as-sembly. Additionally, the pressure rise andincreased noise level associated with freevented explosions are massively reducedto negligible levels. After an explosionevent the Q-Rohr®-3 is re-usable imme-diately after cleaning and replacement of the REMBE® Rupture Disc assembly.
Explosion protection at milling hopper in breweries
* see below · Further connections, technical drawings on request – see Q-Box for rectangular connections
TypeDN*
NPS (in)
max.H*
A*max.W*
WR-Ø* BC-Ø* Ø d* n* weight
mm inch mm inch mm inch mm inch mm inch mm inch kg lbs
Q-Rohr®-3 - 8 200 / 8" 600 236 350 13.7 410 16.2 268 10.6 243 9.6 8.5 0.33 8 25 55
Q-Rohr®-3 - 12 300 /12" 600 236 450 17.7 500 19.7 390 15.4 355 13.9 11 0.43 12 30 66
Q-Rohr®-3 - 16 400 /16" 900 354 550 21.6 600 23.6 500 19.7 443 17.4 13 0.51 16 48 106
Q-Rohr®-3 - 20 500 /20" 900 354 650 25.5 700 27.6 600 23.7 544 21.5 13 0.51 20 60 132
Q-Rohr®-3 - 24 600 /24" 1400 551 760 29.9 810 31.9 700 27.6 646 25.4 13 0.51 20 125 276
Q-Rohr®-3 - 28 700 /28" 1900 784 860 33.8 910 35.8 800 31.5 752 29.6 13 0.51 28 195 430
Q-Rohr®-3 - 32 800 /32" 2200 866 960 37.7 1010 39.7 900 35.5 854 33.6 13 0.51 28 240 529
Technical DataRupture pressure (PStat) 0.1 bar g @ 22° C / 71.6 °FPred 0.1 bar g to 1.3 bar gMax. KSt-value 250 bar x m/sOperating temperature -10 °C to +230 °C / 14 °F to 446 °F
WR Ø
BC Ø
max. W
DN
Bursting discConnecting flangewith mounting holes
[amount n and diameter d]
A
max
. H
We offer
special so
lution
s
for KSt-v
alues
≥ 350 b
ar x m/
s.
Opera
ting
temper
atures
up to
600 °C
(1,112°
F)
on req
uest.
Specialfilters for
gas explosions and hybrid mixtures on
request!Rupture Disc
11
Explosion protection of a filter-cyclonecombination in the fast food industry
Q-Rohr® installed in a recycling plant
Q-Rohr® for protection of a cocoa roasting plant
Q-Rohr®-3
TYPICAL APPLICATIONS OF EXPLOSION VENTING
Pat.-No. DE 38 22 012U.S. Patent pending
The Q-Rohr® protects the suction system at an aircraft manufacturer.
Q-Rohr® installed in a milk powder factory Q-Rohr® installed in a sugar refinery
12
U.S. patents pending
The Q-Box II flame-reduced explosion vent can be used to great effect eitheroutdoors or indoors. When used indoorsit dispenses with the headaches of posi-tioning complex, cumbersome and expensive vent ducting.
The Q-Box II providing low pressure resistance, effectively eliminates flameand heat emissions thereby allowing easyindoor installation and positioning of relevant machinery.
Rectangular connections of the Q-Box IIcomplement the dimensions of the stan-dard rupture panels thus allowing retro-fitting of Q-Box II for existing installati-ons.
Available in two standard sizes Q-Box II offers the best possible solution and the perfect safety system for indoor devices such as elevators when compared to often poorly designed and inefficient venting ducts.
Q-Box safeguarding a FilterhousingQ-Box duo in action
…fireproof sanitary coversare also available.
EXPLOSION VENTINGWITH FLAME ABSORBER…
Q-Box II
Q-Box I
I
in two
standard
sizes
13
U.S. patents pending
The basis of development for the Q-Box II: Heat flow and dispersal analysis as the rupture disc membrane opens into the Q-Box.
Explosion venting with the Q-Box II, no escaping flames
Q-Box on the foot of an elevator
Q-Box application in the food industry
All dimensions are nominal - further sizes on request.
Your benefits at a glance
optimized production processes
safe transport routes
easy and quick installation
Advice
Q-Box II Type305 x 610 mm 586 x 920 mm12 x 24 in 23,2 x 36,2 in
Heightmm 500 780
inch 197 307
Weightkg 35 95
lbs approx. 77 209
Rupture pressure (PStat) 0,1 bar g @ 22° C / 71.6° F
Pred: up to 0.5 bar g
max. KSt-value up to 200 bar x m/s
Operating temperature -30° C + 180° C / -22° F to 356° F
Technical Data
Q-Box II
…FOR INDOOR AND OUTDOOR APPLICATIONS
Integrated REMBE®-rupture disc with signaling and flange seals,
also in aseptic, sanitary and sterile designs
Layers of SST flame arrestermesh enabling dust retentioneffectiveness
Connection case for operational and alarm displays
14
EXPLOSION-, SPARK- AND FLAME FRONT ISOLATION…
EXKOP® II Pat.-No. EP 05 59 968
Proven isolation of pipelines with EXKOP®II
The EXKOP® system provides safe and economic and easy explosion-, spark- andflame front isolation. The pinch valvesprotect interconnected equipment byhigh speed closure of a fast acting rubberhose.
The valve is triggered by 100 % reliable signal from the maintenance-free triple-section rupture disc, the Q-Rohr®-3 or byIR-, pressure or temperature sensors. The complete system is failsafe due to anintegrated pressure storage tank and self-monitoring controller. In case of explosionthe plant personnel can reset the EXKOP®
system quickly and easily after inspection.Plant downtime is reduced to a minimum.
The compact design makes it possible toinstall the system at any site independent-ly of the building-in position. Comparedwith the immense mass acceleration ofknife gate valves during closing operationthe space-saving quench valve does notrequire any special supporting structure,e. g. braces or bases.
Quench Valve (QV II)
Your benefits at a glance
failsafequick resetreinforcements not necessarybi-directional function
Advice
FSA04ATEX1537X
Further sizes on request
The EXKOP® MINI has especially been developed for applications with 1-2 pinchvalves. Two separate inputs (rupture pa-nels, Q-Rohr®, spark detectors, etc.) canbe combined with two QV II valves.
The use of the system is simple and worksacc. to the „one button easy handling”philosophy. As usual all events are obser-ved by a ring storage memory.
EXKOP® MINI installed in the plastic-compounds industry
EXKOP® MINI
Diameter Quenchseal Quality
DN 80 (3") to DN 250 (10") natural rubber abrasion resistent
DN 80 (3") to DN 250 (10") natural rubber food quality
15
With the non-return explosion valve series Q-Flap explosions in nearly all industrial sec-tors can effectively be isolated. The Q-Flap is certified as a protective system acc. to EUguideline 94/9/EG (ATEX 95) and approved for decoupling explosions of organic and inor-ganic dusts.
In case of an explosion the Q-Flap closesdue to the pressure front spreading wit-hin the ductwork. The explosion flameand the pressure cannot strike back theductwork. Personnel working at capturingpoints or downstream system parts areprotected against the explosion effects.The flap damping element prevents theflap to open shortly after an explosiondue the appearing low pressure.
The passive non-return Q-Flap protects horizontal aspiration lines with a flow velocity between 15-30 m/s.
Extensive research and testing under real explosion conditions enabled ap-proval of the Q-Flap for St 1 or St 2 (max. KST-Value = 300 bar x m/s). Q-Flap is applicable for reduced pressure (Pred) up to 0.5 bar (7.25 Psi).
Additionally the Q-Flap Plus offers a wear-and-tear sensor that monitors theabrasion that could possibly occur on the stainless steel flap. The Q-Flap is alsoequipped with an integrated cloggingsensor that indicates any kind of productaccumulation underneath the seats whichensures safe closing of the flap.
Q-Flap Plus installed in a food application
Q-Flap® / Q-Flap Plus
…OF PIPELINES
The Q-Flap is the only valve that allows easy maintenance as a result of the service opening.
Downstream explosion isolation in industries, e. g.
chemical and pharmaceuticaltimbervarnishglas fibre blating
Applications
dust collectorsair separatorsmillsfilter systems, etc.
16
Redundant p-RED pressure sensor
Q-Bic on a top of an Elevator
Q-Bic twin solution
Q-Bic in a large pipe
Q-Bic extinguishing bottle Protection of pipes and vessels
Explosion suppression system at a big hopper
Q-Bic®
EXPLOSION SUPPRESSION SYSTEM - OPTIMIZED FOR INDIVIDUAL REQUIREMENTS
The Q-Bic system is suitable for indoor applications where the explosion cannotbe discharged to the outside atmosphere.It extinguishes the explosion at the pointof ignition.
Combustions are identified and imme-diately suppressed due to the prompt blowing out of dry powder in the endan-gered area. The dry powder extracts theheat. The explosion is inerted. As the explosion is limited consequential lossesare reduced to a minimum.
Your benefits at a glance
detection via a redundant detector
reliable technology
safe and cost-efficient isolation of big pipes > DN 300 (12”) and rectangular shafts
Advice
17
Signaling
Insulation / Gaskets / Services
ACCESSORIES / OPTIONS
BIRD (Burst Indicator REMBE® Design) -ideal for retrofitting
Type BIRDThe BIRD Signaling unit is offered for existing rupture disc or explosion panel installations that do not have a Signalingdevice installed. A ceramic bar incorpora-ting electrical conductors is mounted inthe flow direction downstream of thedisc/panel. When the disc/panel actuatesthe element breaks (fragments) and theclosed circuit is interrupted.
SSL fibre optic signaling unitIf the optic fibre cracks due to the move-ment of the rupture panel the light stre-am of this waveguide is interrupted. Thedownstream optoelectrical converter im-mediately provides an electrical signalwhich can also be used for electronic dataprocessing. The SSL fibre optic signalingunit is aluminium coated and heat resi-stant up to 932° F.
Triple-section-rupture discincl. signaling unit SK
Actuation of rupture discs and explosionpanels can be detected by utilizing a si-gnaling cable. The Signaling device is ultralow current and is intrinsically safe andoperates on a simple Open-Closed princi-ple (normally closed). Different standardtypes are available:
Type SK / RSK / SRThe Signaling cable is installed at thebreaking point of the disc/panel. Whenthe disc/panel actuates, the closed circuitis interrupted due to the cable break. TheSignaling cable is a well proven reliablemethod. No additional assembly is requi-red and no moveable parts remain.
Assembly Accessories If required assembly kits comprising offrames with corresponding bolts and nutsare available in Galvanized Steel or Stain-less steel.
External Insulation When specified REMBE® rupture discs/panels are manufactured with a weather-proof insulation. Only closed-cell elasto-mer with reflecting high efficient coatingis used. The insulation is permanently con-nected to the disc/panel and is of ultralight weight. It has no impact or adverseeffect on the functionality and burst ra-ting of the relieving device.
Gaskets Following gasket qualities (see table) are available as accessories:
FDA approved materials for sterile appli-cations, e. g. silicone, EPDM are available.Further gasket qualities on request.
Certifications, Inspections, GuidelinesAll REMBE® Rupture discs/Panels are cer-tified in accordance with NFPA and ATEX94/9 EG. Each individual batch (lot) aremanufactured and tested in compliancewith the requirements of prEN14797.
Individual test certificates in accordancewith EN 10204-3.1. are supplied as a stan-dard.
The REMBE® quality management systemalso complies with NFPA, CSA, ATEX ,ASME VIII DIV 1, KTA 1401, China CML,ESA.
Sizing / Selection REMBE® provide support in ensuring cor-rect product selection for any given instal-lation/location, ensuring fit for purpose,trouble free and cost effective ownershipof rupture disc and explosion panel pro-ducts.
Additionally REMBE® are happy to sup-port you with sizing your required effec-tive venting area. Calculations are madein accordance with VDI guideline 3673, EN 14491, NFPA 68, API and ASME VIII, etc.
GasketQualities
Temperature in
° C ° F ° C ° Fmin. max.
EPDM black -50 -58 150 302
EPDM white -40 -40 120 248
Silicone -40 -40 180 356
Klingersil -100 -148 400 752
Also ask for an explosion consultant from REMBE® to help specifying the perfect solution concept.
18
In more than 35 years REMBE® has built up a highly qualifiedteam of experts. This unique experience in applications com-bined with our technical know-how gives you the confidence required when planning and carrying out your explosion protection concept.
Your benefits at a glance
1. REMBE®’s active cooperation in international standardisation committees and boards
We continuously introduce our knowledge and innovative ideas into European and international boards, such as CEN, NFPA, ESMG, VDMA, WJI, INDEX, VDI, ABNT and RosGORTECHNADZOR.
2. On site consultation
After having visited the production line at your company our specialists will work out an appropriate tailor-made concept acc. to your requirements. REMBE® engineering relishes an excellent reputation worldwide.
3. Optimized process safety leading to big cost savings
You reduce your insurance payments by implementing a comprehensive safety concept. If you intend to invest in the safety of your plant our experts will advise you.
4. Rembe®’s Technical Seminars
We offer basic and detailed training in pressure and safety protections systems including live demonstrations for up to 200 participants at a suitably insured site of aclients choice.
INTELLIGENT AND COST-SAVING EXPLOSION PROTECTION CONCEPTS
Gerd MayerPresident REMBE®, Inc.Charlotte, NC / [email protected] +1 (704) 716 7022 - 222
Since 2006 at REMBE®, Inc.
19
SPECIALISTS AT REMBE® GLOBAL NETWORK
Roland BunseManager Explosion Protection Department / Product Manager [email protected] +49 (0) 29 61 / 74 05 - 112
Since 1994at REMBE®
Georg VonnahmeSenior Sales Engineer / Manager Replacement [email protected] +49 (0) 29 61 / 74 05 - 111Since 1981
at REMBE®
Felix Obermeyer Sales and Business Development [email protected] +49 (0) 29 61 / 74 05 - 301
Since 2007at KERSTING
Brent ArmstrongInternational Sales Sampling/Electrostatic Grounding [email protected] +49 (0) 29 61 / 74 05 - 303Since 2008
at KERSTING
Sarah MatthäusSales AssistantExplosion Protection [email protected] +49 (0) 29 61 / 74 05 - 116Since 2005
at REMBE®
Orhan KaragözInternational Sales [email protected] +49 (0) 29 61 / 74 05 - 110
Since 1990at REMBE®
Thomas MünstermannManager Process Safety Department / Product [email protected] +49 (0) 29 61 / 74 05 - 113Since 1998
at REMBE®
Uwe SteigerManaging [email protected] +49 (0) 29 61 / 74 05 - 350Since 2006
at REMBE®
FIBRE FORCE GMBH
Max EgenTechnical [email protected] +49 (0) 29 61 / 74 05 - 351Since 2009
at REMBE®
FIBRE FORCE GMBH
REMBE® GMBH SAFETY + CONTROL
Headquarter and Factory Brilon / [email protected] +49 (0) 29 61 / 74 05 - 0
Michael M. MacClancyManaging DirectorLondon / U.K.T +44 (0) 207 630 03 [email protected]
Dirk JörgensSales DirectorMiddle East / [email protected] +49 (0) 29 61 / 74 05 - 118Since 2009
at REMBE®
Eugenia NickelBusiness Development Manager Eastern Europe [email protected] +49 (0) 29 61 / 74 05 - 114Since 2006
at REMBE®
Peter ZabelGeneral ManagerREMBE®
Representative Office Singapore [email protected] +65 6246 2053
Since 2009 at REMBE®
R U P T U R E D I S C S
B R E AT H E R VA LV E S
E X P L O S I O N R U P T U R E PA N E L S
E X P L O S I O N P R O T E C T I O N S Y S T E M S
S A M P L I N G A N D G R O U N D I N G
F I B R E O P T I C S
P R O D U C T S P E C I A L I S T S
Since 2009 at REMBE® LTD
Explosion Pentagon
6
Booklet of Safety + SecurityYou are interested in learning more?
This booklet gives you basic knowledge to the subject of dust explosion protection as well as useful information about efficient and cost-saving plant protection.
R E M B E ® A L L I A N C E
Proudly distributed by:
3809 Beam Road Suite KCharlotte, NC 28217T +1 (704) 716 7022F +1 (704) 716 7025 [email protected]
The copyright of all contents in this catalogue with its design, text, photos and graphics is owned by REMBE®, INC. (except where otherwise stated); all rights reserved. REMBE® does not accept responsibility for any mistakes or technical changes which may occur due to progress in research and development. All copies made of this catalogue are legally prohibited. REMBE® reserves the right to change or update any information in this catalogue without notice. REMBE® will not accept any responsibility for mistakes that occur in the production or in the use of this catalogue. It is the sole responsibility of the operator to ensure
that all REMBE® products are correctly used.REMBE®- All rights reserved · ars nova · USP-EPD-09195/0-Valid from 2009-11-20-3.000
www. | rembe.us | rembe.co.uk | rembe.de | rembe.sg |
Please d
ownload
at www
.rembe.u
s
or call f
or: T +1
(704) 71
6 7022