Upload
julian-patterson
View
140
Download
17
Tags:
Embed Size (px)
DESCRIPTION
UPS SG-CE Series 160-300 kVA. Sales presentation. PRODUCT HIGHLIGHT. Product portfolio CE Marked, 3x380/400/415V In & Out, 50/60Hz. UPS SG-CE Series 160kVA144 kW UPS SG-CE Series 200kVA 180kW UPS SG-CE Series 160kVA PurePulse TM 144kW UPS SG-CE Series 200kVA PurePulse TM 180kW - PowerPoint PPT Presentation
Citation preview
UPS SG-CE Series 160-300 kVASales presentation
SGSE_250-300_S1_UPS_01
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt2
PRODUCT HIGHLIGHT
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt3
Product portfolioCE Marked, 3x380/400/415V In & Out, 50/60Hz
SGSE_160-200_S1_UPS_01
SGSE_250-300_S1_UPS_01
160 – 200 kVA
250 – 300 kVA
UPS SG-CE Series 160kVA 144 kW UPS SG-CE Series 200kVA 180kW
UPS SG-CE Series 160kVA PurePulseTM 144kWUPS SG-CE Series 200kVA PurePulseTM 180kW
UPS SG-CE Series 250kVA 225kWUPS SG-CE Series 300kVA 270kW
UPS SG-CE Series 250kVA PurePulseTM 225kWUPS SG-CE Series 300kVA PurePulseTM 270kW
IGBT rectifier
Thyristor rectifier
IGBT rectifier
Thyristor rectifier
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt4
Double conversion parallelableDesigned for Mission Critical Applications
True On-Line Double Conversion
VFI technology(Voltage and Frequency Independent)
Inverter output transformer for load galvanic separation
Inverter
DC
Battery bank
AC
AC
DC
Static bypass
Rectifier
Bypass supply
LoadRectifier
supply
SGSE_160-200_S1_RPA disposition_01
UPS 1UPS 2
3 - 4 - 5 - 6UPS
Redundant Parallel Architecture™
RPA™ up to 6 UPS unitsIncrease system reliability and
securityExpanded UPS installed power
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt5
High power concentrationNew technology for actual and future trend
SGSE_160-200_S1_UPS_01
1900
850 1350/1500
Reduced footprintCompact design saving space in
installation:
- 160-200 kVA: 1350 x 850
x 1900 mm
- 250-300 kVA: 1500 x 850
x 1900 mmFull active power availableFull power capability to supply
- inductive loads- resistive loads- capacitive loads
Suitable for actual loads applications, e.g. capacitive loads in new datacentre
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt6
Performances for actual and future trendHigh efficiency and clean input technologies for modern applicationsEfficiency
0%
20%
40%
60%
80%94%
100%
10% 25% 50% 75% 100%
Load
Effi
cie
ncy %
Typical Operation
High efficiency at any loadHigh efficiency at full and partial loads for real benefit in operating conditions
Clean input UPS by PurePulse™ technologyNo input current distortion:
THDi = 2% at 100% load
2.5%at 75% load3% at 50% load
Input power factor: PF=0.99
Total Input Harmonic Distortion
Load
0%
1%
2%
3%
4%
5%
0% 20% 40% 60% 80% 100%
TH
Di
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt7
Superior output dynamic stiffness Technology for actual and future trend
output voltage
current
Voltage variation at 0–100% load step
output voltage
load step 0-100%
Voltage stability at loads stepsCapability to supply critical loads
with high and fast loads steps(pulsating loads)
No oversize required for pulsating loads
output voltage
load step 0-100%
No output voltage distortionReal sinewave output voltage with
linear and non-linear loadsReduced stress for load power
supply equipments
Output voltage with non-linear load
output voltage
current
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt8
TYPICAL APPLICATIONS
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt9
Typical applicationsDesigned for mission critical applications, with highest levels of protection and reliability
Data centers
Medical equipment & healthcare facilities
Transportation & Infrastructure
Call centres
Security system
and more ...
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt10
IEC 62040-3
CLASSIFICATION
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt11
Performance IEC 62040-3 – Level 1Output voltage dependancy
Level 1: Output voltage dependency from utility (XXX YY ZZZ)
VFI – Voltage & Frequency Independent
Topology: Double conversion/on-line Inverter
~ - -~
Load
Rectifier
Utility
Battery
VI - Voltage Independent
Topology: UPS-Utility-Parallel operation /Single conversion / Line-interactive
Utility
Inverter &Charger
~~
Load
Converter
Impedance
-~
Battery
VFD – Voltage & Frequency Dependent
Topology: Off-line ~ - -~BatteryCharger Inverter
Utility
Switch
Load
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt12
Performance IEC 62040-3 – Level 2Output voltage quality
Level 2: Output voltage quality depending on load (XXX YY ZZZ)
Sine wave: THD < 8% (IEC 61000-2-2/-4) for all linear and non-linear loads
Non-sine wave: THD > 8 % with non-linear load
Non-sine wave: out of tolerance of IEC 61000-2-2/ -4
S
X
Y
S
X
Y
Battery operation
Normal operation
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt13
Performance IEC 62040-3 – Level 3Dynamic output voltage
Level 3: Dynamic output voltage behaviour (XXX YY ZZZ)
Class 1
Class 2
Class 3
ZZZ
Dynamic load changes with non-linear load (0% – 100%– 0%)
Dynamic load changes with linear load (0% – 100% – 0%)
Change of operation mode (Utility – battery / Inverter - By-pass)
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt14
SG CE classificationExeeding IEC 62040-3 standard requirements
Class 1
SG-CE Series
SG CE classification: VFI – SSS – 111
VFI Voltage & Frequency IndependentFrequency Converter operation available
SS Output voltage THD < 8% for all loadsTHDv < 1.5% linear loadsTHDv < 3% non-linear loads
111 Class 1 performance Exceeding Class 1‘’Best in Class’’ dynamic response:+/- 3% at load step: 0-100%-0+/- 2% at load step: 0-50%-0
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt15
CHARACTERISTICS
&
PERFORMANCES
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt16
UPS configurationDouble conversion with inverter output isolation transformer
Double conversion (VFI) technology with output isolation transformerAutomatic bypass for overloads, short circuit and UPS disturbances conditions Manual bypass for UPS maintenance operations without load interruptionProtection safety devices integrated (back feed protection k6 standard)
RECTIFIER
BATTERY
SSM
INVERTER
LOA
DS
Q1
Q2
Q4
K3
K6
K7
MANUAL BYPASS
AUTOMATIC BYPASS
INP
UT
MA
INS
INVERTERTRANSFORMER
RECTIFIER
BATTERY
SSM
INVERTER
LOA
DS
Q1
Q2
Q4
K3
K6
K7
MANUAL BYPASS
AUTOMATIC BYPASS
INP
UT
MA
INS
INVERTERTRANSFORMER
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt17
Compact designTrue front access for operation and maintenance, saving installation space
UPS1.600
1.350
850
Footprint SG 200kVAUPS : 1.350 x 0.850 = 1.15 sqmOperational : 1.350 x 1.600 = 2.16 sqm
Reduced footprintCompact design saving space in
installation- 160-200 kVA: 1350 x 850 x 1900 mm- 250-300 kVA: 1500 x 850 x 1900 mm
Easier to handle in narrow space
True front accessInstallation against a wallMore space available for other
equipments
Reduced weighEasier to handle into installation site
(e.g. transportation though floors by lift)
Reduced installation time and cost
SGSE_160-200_S1_UPS_01
1900
850 1350/1500
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt18
Highest UPS output power capabilityCapability to supply Inductive, Resistive and Capacitive loads
Full range power capability Designed to supply real power
for any type of application - inductive loads- resistive loads- capacitive loads
No over-sizing required to supply resistive and capacitive loads
Suitable for modern power
supply application with unit or capacitive power factor (e.g. new servers generation), crest factor up to 3:1
E.g. SG 300kVA load capabilities:
Inductive load PF=0.9 270 kW / 300 kVA
Resistive load PF=1 270 kW / 270 kVA
Capacitive load PF=0.9 270 kW / 300 kVA
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt19
Input rectifier performances Wide input window to preserve battery autonomy and lifetime
Input voltage
Inp
ut
freq
uen
cy
400V +15%-15%
+10%
-10%
50 Hz
Input window
Soft start
100%
0%
UPS input current
time
Wide input voltage and frequency windowsLimited use of battery Preserve battery autonomy for real
input mains failuresIncrease battery lifetime
Soft startRectifier can be activated gradually, controlling the input currentPreventing instable situation for GenSetAvoids false trip of upfront protection devicesSequential softstart for parallel UPS
UPS 1 UPS 2
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt20
Backfeed protection IEC 62040-1 : ……“For fixed installation UPS, backfeed protection may be provided internally or externally to the UPS in the a.c. input line”
Inverter
DC
Battery bank
AC
AC
DC
static bypass
Rectifier
Backfeed contactor
Inputmains
Load
preventing feedback to the mains from the inverter in case of mains failure and a fault in the bypass
circuit
Standard feature inside UPS cabinetNo additional cost requiredNo addition installation required
Fully compliant with IEC 62040-1Compliance to UPS installation safety requirements
Safer operating conditionSafer operation for end users and service engineers
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt21
IGBT technology for clean input Pure Pulse configuration for highest input performances
UPS input performancesTotal Current Harmonic Distortion THDi=2%UPS input power factor: 0.99
Constant behavior at all loadsNegligible harmonics contents at full and partial loads
Benefit on input mainsSaving in the sizing of upfront equipments
e.g. GenSet, cablings, circuit breakers, …No disturbances to nearby equipment Saving cost due to additional filters
PurePulse technology for IGBT rectifier
Total Input Harmonic Distortion
Load
0%
1%
2%
3%
4%
5%
0% 20% 40% 60% 80% 100%
TH
Di
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt22
Perfect integration with GenSetNo GenSet oversizing required
GenSet integration
Example
Load 300 kVA; PF=0.8; 240 kWUPS SG 300 kVA Pure Pulse;
input PF = 0.99
GenSet data reactance subtr. X“d=12%
GenSet size min. size required 332 kVA
GenSet/UPS = 332/300 = 1.1
Compatible with GenSet designSaving GenSet size
(suggested GenSet vs. UPS ratio ~ 1.1*)
Reducing GenSet installation spaceSaving GenSet investment
GenSet system integrationGenSet integration via Customer
Interface (dedicated auxiliary contact)
Programmable functions based on GenSet working condition (Gen on/off)
*Pure Pulse configuration and GenSet able to manage large load steps
SGSE_160-200_S1_UPS_01
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt23
Superior Battery Management Safe and protected battery management to preserve investment and UPS reliabilityFlexible applicationsDifferent battery technologies applicable: PB sealed (VRLA) - PB vented – NiCdWide autonomy range (from few minutes to some hours)
User friendly information Prediction of true back-up time, based on load statusAlarm for “stop operation” to prevent any unknown shut-down
Monitoring and controlBattery test (programmable or manual) ; preserve UPS system reliability Battery earth fault detection; safer
operation for service engineer & end user
Charging voltage = f (battery temperature)
2.18
2.21
2.24
2.27
2.30
2.33
2.36
0 5 10 15 20 25 30 35 40
Battery temperature [°C]
Vo
lt p
er c
ell
Voltage temperature compensation
V
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt24
No output voltage distortion with linear and non-linear loadsVoltage distortion
- linear loads: THDv <1.5%- non-linear loads: THDv < 3%
Enhanced customer productivityImproved quality of application, reducing stress for loads supplied Increased uptime and MTBF of customerReduced service intervention
(e.g. medical applications: ~60% labor hour & spare parts reduction)
Output voltage with non-linear load
Output voltage with linear + non-linear load
No output voltage distortion Best in class inoutput dynamic stiffness
output voltage
output voltage
current
current
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt25
Medical scanner - dynamic current absorbtion
Best in class in output voltage variation with load steps:Static : < + 1%Dynamic at load steps 0-50-0% :
< + 2%Dynamic at load steps 0-100-0% :
< + 3%
Enhanced customer unit productivityImproved quality of application
(i.e. medical images)Capability to supply critical loads with high and fast loads steps (pulsating loads) Increased uptime and MTBF of customerReduced service intervention
1 ms
Output Dynamic Stiffness Best in class inoutput dynamic stiffness
Voltage variation at 0–100% load step
load step 0-100%output voltage
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt26
EFFICIENCY
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt27
High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design
High efficiency performances at any load
High efficiency at full and partial loads for real benefit in operating conditions
Energy cost savingReduced cost of customer
equipment operation at all loads
Air conditioning cost savingReducing size and cost of air
condition systemReducing consumption and
related operating cost
SG CE Thyristors rectifier – Efficiency*
0%
20%
40%
60%
80%
94%100%
10% 25% 50% 75% 100%
LoadEffi
cie
ncy %
Typical Operation
* SG CE PurePulse (IGBT rectifier) 1% less
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt28
Normal modeThe output voltage is newly
generated, independently from the input voltage
Heat losses are present in rectifier and inverter
Super Eco ModeLoad is supplied via the
bypassUPS rectifier keeps the battery
chargedUPS inverter switched off
(no heat losses)
Super Eco Mode - functionalityImproving UPS efficiency
Super Eco Mode
Normal mode
Inverter
DC
Battery bank
AC
AC
DC
Static bypass
Rectifier
Bypass supply
LoadRectifier
supply
Inverter
DC
Battery bank
AC
AC
DC
Static bypass
Rectifier
Bypass supply
LoadRectifier
supply
Transf.
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt29
High efficiency: 98%prevents heat lossessaving customer utility bill
Fast transfer time to inverter: <2 ms Guaranteed safe energy for the application
Configurable according to load requirementAdjustable bypass supply tolerance
- voltage: +/- 10% (adjustable)- frequency: +/- 5%
(adjustable)
Super Eco Mode - benefitHigh efficiency, preserving protection to critical load
Bypasson/off
Invertercurrent
Inverter
control
Output voltage
< 2ms
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt30
RPA
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt31
Reduntant Parallel Architecture True redundancy with no single point of failure
rectifier bypass rectifierbypass
critical load
DC
AC
AC
DC
battery
Input mains
DC
AC
AC
DC
battery
Modular designFuture system expansionSaving investment
True redundancyNo single point of failureDecentralized bypassDistributed parallel management
system
Increased system reliabilitySafe and reliable power supply for
“mission critical applications”Increase productivityTrue redundancy with no single
point of failure
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt32
Configurable up to 6 units in parallel
Future expansion Safe and reliable power supplyRedundant Communication Bus
Easy to install and maintainEasy system
upgrade/downgradeMaintenance operation without
load interruption critical load
utility supply
Reduntant Parallel ArchitectureIncrease system reliability for Mission Critical Applications
redundantcommunicationbuses
SGSE_160-200_S1_UPS_01
SGSE_160-200_S1_UPS_01
SGSE_160-200_S1_UPS_01
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt33
EMC
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt34
EMC - Electro Magnetic Compatibility immunity IEC 62040-2 standard defines the limits of maximum allowable levels of emission of electromagnetic disturbances for UPS systemsEmissionAny electronic devices emits electromagnetic disturbances - radio frequency waves - through:- cables (conducted emissions)- air (radiated emissions)
ImmunityAll electronic equipment is sensitive for electromagnetic waves.These waves can disturb the functions of these equipments
Electro Magnetic CompatibilityDisturbances tolerance among different types of equipment when running in the same environment.
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt35
EMC Category C2 (Class A), optional feature* Compensation of radio-frequency emission to avoid distrurmabces on nearby equipmentsNo interference with other equipmentsAvoid any interferences with critical
applications sensitive to radio frequency emission (e.g. telecom, broadcasting, …)No additional investment required for EMC investigation.
Protected unit quality enhancementIncreased quality and productivity
(e.g. Image quality in medical application)*Additional EMC cabinet
required
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt36
SERVICEABILITY
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt37
Designed for serviceabilitySaving time and cost in service
Easy maintenance intervententionReducing time and cost on maintenance intervention Reducing down-time, increasing availability
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt38
Fan failure detectionVentilation monitoring for highest reliability
Ventilation monitoringAlert before overheating occursContinuos monitoring of cooling
system Repairing time reduction Fault level decreasing
fan failure
detection
alarm
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt39
POWER QUALITY
SYSTEMS
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt40
Power Quality Systems Integretion with other Power Quality euipments for Mission Critical Applications
IS
M_C
abin
et_G
E_0
1
U P S 1U P S 2
3 - 4 - 5 - 6U P S
U P S 1U P S 2
3 - 4 - 5 - 6U P S
UPS-A
UPS-B
Battery-A
Battery-B
ISM
STS-A
STS-B
Load-A
Load-B
Input
mains
Input
mains
UPS: Uninterruptible Power SupplyISM:Intelligent Synchronization ModuleSTS: Static Transfer Switch
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt41
INTEGRATION WITH BMS
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt42
Customer interfaceEasy integration with Building Management System (BMS)
Customer interfaceUPS supervision capability1x RS232 Serial Communication
Port6 programmable potential free
alarm contacts: - D plug - Terminals blocks
1x Emergency Power OFF contact1x Gen-ON Input contact1x Control Input contact
Additional interface:SNMP Interface Card
(10/100Mbps auto-select)MODBUS RTU Interface (RS232 or
RS485)
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt43
CONNECTIVITY
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt44
Data Acquisition
Communication
Medium
User Interfac
e
IRISInfrastructur
e
SNMP/Modem/GPRS topologies available
Flexible, safe and customer-friendly solution for remote monitoring
Secure communication via: e-mail, SMS, faxGPRSWeb/PDA
IRIS - Intelligent Remote Information System Remote monitoring and diagnostics solution
SG-CE Series 160-300 kVA S1Sales presentation
SAP_SGS_XCE_M16_M30_1GB_V020.ppt45