Uninterrupted power supply systems for protection and backup applications
Citation preview
These specifications may be changed without notice
6 sockets
Space for connecting a large adaptor
Secondary fuses for mains connection and MOVs. Offers protection for tel/fax/modem
5 Sockets
7 Sockets
Cable integrator
Resettable fuse
GENERAL SPECIFICATIONS
Model SIL 5 Sockets SIL 6 Sockets SIL 7 Sockets
Reference 014853 014854 014855
High frequency capacitor Eliminates interferences
Optional Varistor (MOV) multiple metal oxide Absorbs overvoltages, offers constant protection against voltage spikes
Safety stop Thermal fuses to shut down the system, protection against fire and other damagein the case of overvoltages
Protection Secondary fuses for the protection of the mains connection and MOVs.Offers protection for Tel/Fax/Modem
5/6/7 AC sockets with safety device for children Helps to protect users and their children, avoiding dirtand malfunctions due to disuse
Protection indicator The red light indicates that the overvoltage protector is operating correctly
Mains connection Resistant power cableLength 2 metres
Protection Resettable fuse
Supply switch On or off signal
OTHERS
Indicators - Extra space for connecting a transformer
- - Cable integrator
LED “POWER OK”Comes on if the Overload Protector is connected
correctly to an earthed socket
1 2 schucko sockets con respaldo
2 2 schucko sockets sin respaldo
3 2 IEC sockets con respaldo
4 Input/Output línea telefónica
5 Communications port
6 Breaker
1 2
3
45
6
1
2
3
6
5
4
GENERAL SPECIFICATIONS
Model Ebro 650 50 Ebro 850
Reference 018591 018592
Power 600 VA/ 360 W 850 VA/500 W
Topology Interactive line Interactive line with AVR
INPUT
Voltage range 175-265 Vac 165-275 Vac
Nominal voltage 220/230/240 Vac
Frecuency 50Hz ±5%
Maximum current input 3.2A (in bypass) 3.8A( in bypass)
Nominal voltage output 220/230/240 Vac
OUTPUT
Maximum current output 2.7A 3.9 A
Voltage (normal mode) 175 Vac-265 Vac±3% 220/230/240 Vac + 10% - 15%
Voltage (battery mode) 220/230/240 Vac ±10%
Wave form Synchronised (sinusoidal wave)
Output frequency (battery mode) 50Hz ±0.5
Overload capacity 110-120% (60 seconds)
Power factor 0.6
Transfer time <10 mS
BATTERIES & AUTONOMY
Standard battery Maintenance-free, lead battery with anti-leak seal, VRLA type
Battery module included 1x12 VDC/7.2 Ah 1x12 VDC/9Ah
Autonomy Up to 10 minutes depending on the load
Charging time <12 hours (90%)
INDICATORS
Luminous Leds: Normal Mains, Battery Mode, Overload/ Failure
Display: Output voltmeter,battery level, normal mains,
battery mode, overload/failure
Acoustic Battery mode, overload/shortcircuit. Buzzer for 60 seconds
COMMUNICATIONS PORT
Control software UPSilon2000
Communications USB port RS232 with USB adapter
Start-up from battery Yes
PROTECTION
Protection High voltage, low voltage, overvoltages, spikes
Protection against overload Yes
Protection against low battery voltage Yes
Protection against output short-circuits Automatic output cut-off, continuous buzzer
Tel/Fax/Modem jack Yes
STANDARDS
Marks CE
Directives EN 62040-1-1: 2003(73/23/CEE-93/68/CEE)
European directive on electromagnetic compatibility EN 62040-2: 2005EN 50091-2: 1995
EN 61000-3-2: 2003EN 61000-3-3: 1995 + A1: 2001
OTHERS
Operation temperature 0ºC to 40ºC
Storage temperature -15ºC to 45ºC
Relative humidity 10% - 95% without condensation
Dimensions WxHxD (mm) 110x515x91 110x295x225
Weight (Kgs) 6.0 7.3
SOCKETS
4 schuko sockets 2 UPS mode / 2 lightning arrester mode
2 IEC sockets UPS mode
These specifications may be changed without notice
202E
NF
T00
1
2
3
4
5
6
Phone line protection
USB communication port
IEC outputs (3,4 or 5 depending on model)
Output without UPS protection
Fused mains input
Re-start switch
1 2
3
4 5
6
Specifications may be changed without notice
GENERAL SPECIFICATIONSModel Danubio 500 Danubio 700 Danubio 1000 Danubio 1600 Danubio 2000Reference 018400 018401 018402 018404 018405Power VA 500 700 1000 1600 2000Topology Interactive line con AVRTechnology In-LinePerformance 95%Overload 125%- 60 secINPUTInput voltage 170~290VacFrecuency 50Hz ±5%OUTPUTPower (VA/KW) 500/300 700/420 1000/600 1600/960 2000/1200Voltage (normal mode) 230Vac ± 10%
Output frequency 50 Hz synchronized (±0,5% battery mode)
Output number 3 IEC 4 IEC 5 IEC
Switch time 6ms (typical)BATTERIES & AUTONOMY
Standard battery Pb VRLA (lead battery with anti-leak seal)
Autonomy Up to 30 min. depending on connected load
Charge time 8h-90%
Automatic re-start selectable - Yes - - Yes
INDICATORS
LCD display AC unusual/ Battery low voltage/ Overload/ Short circuit/ PCB failed
Audible alarms High voltage/ Low voltage/ Surge/ Spike
COMMUNICATION
Control software UPSilon 2000
Communications USB
Indicators Automatic functions checking: voltage, input/output frequency, load status, battery capacity, tem-perature, historic events, system analysis,7 alarms type: Beeper, network, e-mail, SMS, acoustic,
telephone, windows warningStart-up from battery Yes
PROTECTION
Protections Suppression of voltage surges, frequency out of range, LVD, overload and shortcircuit.
Data line protectionRJ11/RJ45
STANDARDS
Marks CE
Directives EN 50091-1 / EN 50091-2
OTHERS
Operation temperature 0-40ºC
Relative humidity 0-90% (non condensing)
Dimensions WxHxD (mm) 90x325x165 90x325x165 163x370x210 150x460x220 150x460x220
Weight (Kgs) 6,8 7 15,2 21 24,5
1 Input
2 Outputs
3 RS232 communication port
4 Fuse (1 KVA 10’ model)
5 Mains power breaker
1
2
3
4
5
6
1
2
3
EPO: emergency power off6
3
USB communication port
Bypass breakers
5
SNMP card (optional)
Manual maintenance Bypass (optional)
Line bar cover
* For models over 6 KVA, 1 year warranty.* * Model 1,2 and 3 KVA and 10’ of autonomy, internal batteries, consult weights and dimensions for these models. Rest of UPSs and autonomies, external battery module, consult weights and dimensions.
Specifications may be changed without notice.
GENERAL SPECIFICATIONSModel Volga 1 Volga 2 Volga 3 Volga 6 Volga 10Reference 018102 018103 018104 018265 018266Power KVA * 1 2 3 6 10GENERALTechnology On-Line, double conversion, high frecuencyOverload 105-130% up to 60 secINPUTVoltage range 163~273Vac 170~276VacFrecuency 50Hz ±5%Power factor ≥0.98OUTPUTPower (KVA/KW) 1/0,7 2/1,4 3/2,1 6/4,8 10/8Voltage (normal mode) 230Vac ± 2%
Output frequency 50Hz ±0,5% (battery mode)
Outputs 3 IEC 6 IEC Terminals
Type of wave Pure sinewaveHarmonic distortion THD <3% (linear load)Crest factor 3:1
BATTERIES & AUTONOMY
Standard battery Lead battery with anti-leak, VRLA type
Autonomy Up to many hours (depending on connected load)
Charge time 8h-90%
INDICATORS
LCD display (≥6Kva) Mains on/ UPS fault/ Overload/ low battery
Acoustics Line failure, overload, low battery
COMMUNICATION
Control software UPSilon 2000
Communications RS232
Indicators Automatic functions checking, Input and output voltage/ Frequency/ Temperature/ Load level/ Battery level/ Events History/ System analysis, 7 types of warnings
SNMP card optional RS232 Ethernet converter
PROTECTION
Protections Current limitation, overload
Automatic bypass Yes
RFI filter Yes
PFC: Power factor corrector YesSTANDARDS
Marks CE
Directives EN 62040-1-1:2003 / EN 50091-2:1996 / EN 61000-3-2:2000 and EN 61000-3-3:1995+A1:2001
OTHERS
Operation temperature 0-40ºC
Relative humidity 0-95% (non condensing or ice)
Altitude without decreasing power 1000 over sea level
Acoustic level <45dBA <60dBA
Dimensions WxHxD (mm) 198x490x347 198x490x347 198x490x347 255x640x500 255x640x500
UPS Weight * * (Kgs) 32 14 15 26 27
1
2
3
4
5
3 4
5
12
123
4
GENERAL SPECIFICATIONSModel Rhin 1 Rhin 2 Rhin 3Reference 018262 018263 018264Power KVA 1 2 3GENERAL
Technology On-Line, double conversion, high frequencyOverload 130%- 60 sec, 150% for 30 sec.INPUTVoltage range 170~290 VacPFC ≥ 0,98Frecuency 50 Hz ±5% Conexiones IEC plug TerminalsOUTPUTPower (KVA/KW) 1/0,7 2/1,4 3/2,1Voltage 230 Vac ± 2%
Output frequency 50Hz ±0,5% (battery mode)
Outputs 6 IEC sockets
Type of wave Pure sinewaveHarmonic distortion(linear load) THD <3%
Crest factor 3:1
BATTERIES & AUTONOMY
Standard battery Pb VRLA (lead battery with anti-leak seal)
Autonomy From 5 to 90 min
Charge time 8h-90%
INDICATORS
Leds Line failure, system fault conditions, overload, low battery,
Acoustics Line failure, overload, low battery
COMMUNICATION
Control software UPSilon 2000
Communications RS232 port
Indicators Automatic functions shutdown: voltage, input/output frequency, load status, batterycapacity, temperature, historic events, system analysis, 7 alarms type
SNMP card optional RS232 Ethernet converter
PROTECTION
Protections Current limitation, overload, short-circuit and temperature
Automatic bypass Yes
RFI filter YesPFC: Corrector de factor de po-tencia Yes
STANDARDS
Marks CE
Directives EN 62040-1-1:2003 / EN 50091-2:1996
OTHERS
Operation temperature 0-40ºC
Relative humidity 0-95% (non condensing or ice)
Altitude without decreasing power 1000 over sea levelAcoustic level <45dBA
UPS dimensions WxHxD (mm) 440x486x88 440x486x88 440x486x88Batteries module dimensions WxHxD (mm) - 440x486x132
Dimensions U 2U (UPS+batteries) 2U (UPS)+2U (batteries)
UPS weight ** (Kgs) 14 (internal batteries) 10 11Batteries module weight (Kgs) - 12 16
1
2
3
4
5
6
3 5
12 4
5 6
GENERAL SPECIFICATIONSModel Rhin plus 4,6 Rhin plus 6 Rhin plus 10Reference 018627 018607 018608Power KVA 4,6 6 10GENERALTechnology On-Line, double conversion, parallel
Overload Inverter supply: up to 105/125% for 20 secBypass supply: up to 105/125% for 90 sec
INPUTVoltage range 160~280 VacFrecuency 45~65HzPower factor Up to 0,99 al 100% linear loadOUTPUTPower (KVA/KW) 4,6/3,25 6/4,2 10/7Voltage (normal mode) 200/208/230/240 Vac (selectable)
Output frequency 50/60 Hz (self-sensitive) ±1Hz±3Hz (adjustable)
Type of wave Sinewave, total harmonic distortion <3%, (full load)Efficiency AC to AC Up to 90% (normal), (ECO: up to 95%)Crest factor 3:1
BATTERIES & AUTONOMY
Battery estándar VRLA: Sealed lead acid maintenance free
Autonomy (full load) From 5 to 90 min
Charge time 4 hours to 90%
Voltage 240 Vdc
Batteries cabinet model Internal batteries External batteries
INDICATORS
LCD display/Leds Mains failure, UPS failure, overload, low battery
Acoustics Mains failure, overload, low battery
COMMUNICATION
Communication software UPSilon 2000
Standard interface RS232 Input/output voltage Frequency/ Temperature/ Charge level Battery level
SNMP card Included
Input/Output connection Terminals
External battery connection Plug & playCommunication slots (optionals) 2nd RS232,USB,RS485, relay contact, SNMP/WEB card
PROTECTION
Current limitation Yes
Static by-pass/ manual Yes / optional
RFI filter Yes
Battery charger protector Yes
Display
LCD + LED: Line mode,back-up,ECO mode,Bypass supply, Battery low/bad/disconnect, Overload Transfering with interruption and UPS fault.LCD: Input voltage/frequency, output voltage/frequency, load percentage, battery voltage & inner temperature.
Self diagnostics Upon Power-on,Front panel setting & software control, 24 hour routine checking
STANDARDS
Marks CE
Directives EN 62040-1-1:2003, UL1778, EN 62040-2, EN 61000-3-2, EN 61000-3-3, FCC A class, CE, UL
OTHERS
Operation temperature 0-40ºC
Relative humidity 0Cº-90Cº (non condensing or ice)Altitude without decreasing power 2000 over sea level
Acoustic level <50dBAUPS dimensionsWxHxD (mm)* 440x486x88 (4U) 440x680x88 (2U) 440x680x132 (3U)
Battery module dimensions - 440x680x88 (2U) 440x680x132 (3U)UPS/ Battery weight (kg) 52/- 24/40 26/52
1
2
3
4
5
6
12
34
56
Terminals
Input switch
Maintenance switch
5 6
GENERAL SPECIFICATIONSModel Amazonas 5 Amazonas 6 Amazonas 8 Amazonas 10 Amazonas 15 Amazonas 20Reference 018110 018115 018120 018125 018130 018135Power KVA 5 6 8 10 15 20GENERALTechnology On-Line, double conversion, with galvanic isolationEfficiency >85%Overload 125%- 1 min-150% for 20 ms 125%- 1 min-150% for 0,5 secINPUTVoltage range 180~270VacFrecuency 50 Hz ±5% OUTPUTPower (KVA/KW) 5/3.5 6/4.2 8/5.6 10/7 15/10.5 20/14Voltage 230Vac ± 2%
Output frequency 50Hz ±0,5% (battery mode)
Type of wave Pure sinewaveHarmonic distortion THD <3% (linear load and no lineal) Crest factor 3:1
BATTERIES & AUTONOMY
Standard battery Pb VRLA (lead battery with anti-leak seal)
Autonomy Up to many hours (depending on connected load)
Charge time Depending on battery
INDICATORS
LCD display Operating load/ Battery status and voltage/ Input and output voltage measurement /Input and output frequency measurement/Supplied power
Leds Mains on, by-pass, inverter, low battery, overload, UPS failure
Acoustics Mains failure, overload, low battery
COMMUNICATION
Control software UPSilon 2000
Communications RS232/ RS485 Connectios and dry contacts
Indicators Automatic functions checking: voltage, input/output frequency, load status, battery capacity, temperature, historic events, system analysis,7 alarms type: Beeper, network, e-mail, SMS, acoustic, telephone, windows warning
SNMP card (optional) SNMP Ethernet Conversor Optional
PROTECTION
Protections Current limitation, overload, short-circuit & overtemperature
Manual Bypass No Yes
RFI filter Yes
STANDARDS
Marks CE
Directives EN 50091-2:1996 , EN 50091-2
OTHERS
Operation temperature 0-40ºC
Relative humidity 0-95% (non condensing or ice)Altitude without decreasing power 1000 over sea level
Acoustic level <55dBA <60dBA
Dimensions WxHxD (mm) 230x640x680 230x640x680 300x740x640 300x740x640 480x935x1165
UPS weight * (Kgs) 89.8 91 83 85 145 190
1 SNMP adapter (option)
2 RS232/RS845
3 Communication interface
4 Paralleled Bus
5 Input/output switch
6 Bypass switch
12
34
5
6
234
5 6 5
ESPECIFICACIONES TÉCNICASModel Tamesis 10 Tamesis 15 Tamesis 20 Tamesis 30 Tamesis 40 Tamesis 50Reference 018145 018150 018155 018160 018161 018163Power KVA 10 15 20 30 40 50GENERALTechnology On-Line, double conversion with galvanic isolationEfficiency >92%
Overload 125% 1 min 105%- 10 min:150% 1 min
INPUTVoltage range 322~466 VacFrecuency 50 Hz ±5% OUTPUTPower (KVA/KW) 10/7 15/10.5 20/16 30/24 40/32 50/40Voltage 230Vac ± 2%
Output frequency 50Hz ±0,5% (battery mode)
Type of wave Pure sinewaveHarmonic distortion THD <3% (linear load) Crest factor 3:1
BATTERIES & AUTONOMY
Standard battery Pb VRLA (lead battery with anti-leak seal)
Autonomy Up to many hours (depending on connected load)
Charge time Depending on battery
INDICATORS
LCD display Operating load/ Battery status and voltage/ Input and output voltage measurement /Input and output frequency measurement/Supplied power
Leds Mains on/ By-pass /Inverter/ Low battery/ Overload/ UPS failure
Acoustics Mains failure, overload, low battery
Pulsadores de control On-off / Screen forward
COMMUNICATION
Control software UPSilon 2000
Communications Connector RS232/RS485 & dry contacts
Indicators Automatic functions checking: voltage, input/output frequency, load status, batterycapacity, temperature, historic events, system analysis,7 alarms type
SNMP card (optional) RS232 SNMP Ethernet converter
PROTECTION
Protections Current limitation, overload, short-circuit & overtempertature
Bypass mantenimiento No Yes
RFI filter YesProtection decargador de battery Yes
STANDARDS
Marks CE
Directives EN 62040-1-1:2003 / EN 50091-2:1996
OTHERS
Operation temperature 0-40ºC
Relative humidity 0-95% (non condensing or ice)Altitude without power reduction 1000 over sea level
Acoustic level ≤65dBA
Dimensions WxHxD (mm) 300x740x700 400x800x1180
UPS Weight * (Kgs) 130 195 205 225 273 304
1
2
3
4
5
6
1 2
34
5
6
GENERAL SPECIFICATIONSModel Tamesis plus 10 Tamesis plus 15 Tamesis plus 20
Reference 018266 018267 018268
Power KVA 10 15 20GENERALTechnology On-Line, double conversionEfficiency >91%Overload 105-125%- 10 min:125-150% 1 minINPUTVoltage range 305 ~454 VacPower factor de entrada ≥ 0,98Frecuency 50 Hz ±5%OUTPUTPower (KVA/KW) 10/7 15/10.5 20/14Voltage 220/230 ± 2%
Output frequency 50Hz ±0,5% (battery mode)
Type of wave Pure sinewaveHarmonic distortion THD <3% (linear load) Crest factor 3:1
BATTERIES & AUTONOMY
Standard battery Pb VRLA (lead battery with anti-leak seal)
Autonomy Up to many hours (depending on connected load)
Charge time Depending on battery
INDICATORS
LCD display Operating load/Battery status and voltage/ Input and output voltage measurement /Input and output frequency measurement/Supplied power
Leds Mains on/ By-pass / Inverter/ Low battery/ Overload/ UPS failure
Acoustics Mains failure, overload, low battery
Pulsadores de control On-off / Screen forward
COMMUNICATION
Control software UPSilon 2000
Communications Connector RS232/RS485 & dry contacts
Indicators Automatic functions checking: voltage, input/output frequency, load status, batterycapacity, temperature, historic events, system analysis,7 alarms type
SNMP card (optional) RS232 SNMP Ethernet converter
PROTECTION
Protections Limitador de corriente, sobrecarga, cortocircuito and sobretemperatura
Bypass mantenimiento No Yes
RFI filter Yes
Protection decargador de battery Yes
STANDARDS
Marks CE
Directives EN 62040-1-1:2003 / EN 50091-2:1996
OTHERS
Operation temperature 0-40ºC
Relative humidity 0-95% (non condensing or ice)
Altitude without decreasing power 1000 over sea level
Acoustic level <65dB
Dimensions WxHxD (mm) 255x740x790
UPS Weight * (Kgs) 35 62 63
1 Manual bypass
2 Paralleled Bus
3 Connection ports: RS232/RS485
4 Output/Input/battery/bypass switches
5 Terminals
1 23
4
5
GENERAL SPECIFICATIONSModel OttawaReference Consult models and references depending on power and autonomiesPower KVA 10 15 20 30 40 50 60 80 100 120 160 200 250 300 320 400GENERALTechnology On Line, double conversion with galvanic isolationEfficiency >90%
Overload 125% - 15 min / 150% - 1 min
INPUTVoltage range 322~466 VacFrecuency 50 Hz ±5% OUTPUT
Power (KVA/KW) 10/8 15/12 20/16 30/24 40/32 50/40 60/48 80/64 100/80 120/96 160/128 200/160 250/200 300/240 320/256 400/320
Voltage 400±2% Vac
Frecuency 50Hz ±0.5% (battery mode)
Type of wave Pure sinewaveHarmonic distortion THD <3% (linear load) Crest factor 3:1
BATTERIES & AUTONOMY
Standard battery Pb VRLA (lead battery with anti-leak seal)
Autonomy Up to many hours (depending on connected load)
INDICATORS
LCD display Operating load/Battery status and voltage/ Input and output voltage measurement /Input and output frequency measurement/Supplied power
Leds Mains on/ By-pass /Inverter/Low battery/Overload/UPS failure
Acoustics Mains failure, overload, low battery
COMMUNICATION
Control software UPSilon 2000
Communications Connector RS232/RS485 & dry contacts
Indicators Automatic functions checking: voltage, input/output frequency, load status, batterycapacity, temperature, historic events, system analysis,7 alarms type
SNMP card (optional) RS232 SNMP Ethernet converter
PROTECTION
Protections Current limitation, overload, short-circuit & overtempertature
Bypass mantenimiento Yes
RFI filter Yes
Protection decargador de battery Yes
STANDARDS
Marks CE
Directives EN 62040-1-1:2003 / EN 50091-2:1996
OTHERS
Operation temperature 0-40ºC
Relative humidity 0-95% (non condensing or ice)Altitude without decreasing power 1000 over sea level
Acoustic level ≤50dBA ≤65dBADimensionsWxHxD (mm) 500x800x1180 1200x800x1600 1800x800x2000 (200/250KVA)
2200x800x2000 (>250KVA)UPS Weight * (Kgs) 236 240 295 300 355 360 435 685 785 810 995 1700 1800 2350 2350 2580
1 Output/maintenance/input/bypass/battery switches
2 Paralleled Bus
3 Connection ports: RS232/RS485
4 EPO: emergency power off
5 Terminals
1
23
4
5
GENERAL SPECIFICATIONSModel Ottawa plusReference 018269 018297 018270 018271 018366 018367 018368Power KVA 10 15 20 30 40 50 60GENERALTechnology On Line, double conversionEfficiency ≥90%
Overload 125% - 2 min / 150% - 10 sec
INPUT
Rango de tensión 305~ 454 VPower factor de entrada ≥0,98Frecuency 50 Hz ±5% (±10% optional)OUTPUT
Power (KVA/KW) 10/8 15/12 20/16 30/24 40/32 50/40 60/48
Voltage 380V/400V/420V ± 2% (selectable)Output frequency 50Hz ±0,2% (battery mode)
Type of wave Pure sinewaveHarmonic distortion THD ≤3% (linear load) Crest factor 3:1
BATTERIES & AUTONOMY
Standard battery Pb VRLA (lead battery with anti-leak seal)
Autonomy Up to many hours (depending on connected load)
INDICATORS
LCD display Operating load/ Battery status and voltage/ Input and output voltage measurement /Input and output frequency measurement/ Supplied power
Leds Mains on/ By-pass / Inverter/ Low battery/ Overload/ UPS failure
Acoustics Mains failure, overload, low battery
Control buttins On-off / Screen forward / Acoustic disactivation
COMMUNICATION
Control software UPSilon 2000
Communications Connector RS232/RS485 & dry contacts
Indicators Automatic functions checking: voltage, input/output frequency, load status, batterycapacity, temperature, historic events, system analysis, 7 alarms type
SNMP card (optional ) SNMP Ethernet converter
PROTECTION
Protections Limitador de corriente, sobrecarga, cortocircuito and sobretemperatura
Bypass mantenimiento Yes
RFI filter YesProtection decargadorde battery Yes
STANDARDS
Marks CE
Directives EN 62040-1-1:2003 / UNE-EN 50091-2 (1996)
OTHERS
Operation temperature 0-40ºC
Relative humidity 0-95% (non condensing)Altitude without decreasing power 1000 over sea level
Acoustic level <65dB
Dimensions WxHxD (mm) 400x800x1180 500x800x1600
UPS Weight * (Kgs) 110 113 120 138 215 235 255
GENERAL SPECIFICATIONS
Model SEPEC 200 SEPEC 400 SEPEC 600 SEPEC 800 SEPEC 1200
Reference Turnkey project: design tailor-made for each installationPower KVA 200 400 600 800 1200Total efficiency > 99% in any load condition
Overload 120% permanent regime
INPUT
Voltage range 340-440 Vac (in bypass) (1)
Frecuency admisible 50/60 Hz ± 10%
Harmonic distortion Does not introduce harmonic distortion
OUTPUT
Voltage 340-440 Vac (in bypass)
Frecuency 50/60 Hz programmable
Type of wave Pure sinewave
Active redundancy in inverter Parallel inverters
Crest factor 3:1
Harmonic distortion of output voltage <1.5% (THD)
Power KVA/KW 200/200 400/400 600/600 800/800 1200/1200
BATTERIES (2)
Battery type (Ah) Watertight lead VRLA
Estimated service life 10 years
Air-conditioning Air-conditioning (optional)
Battery current ripple 0 Amps in permanent regime
Autonomy 5 min at full power - PFC 0,8 (other autonomies under consulting)
PROTECTIONS
Voltage impulses Yes (non degradable) operation threshold Unx.1 > 900 Jules
Against short-circuit Yes (permanent)
Current limitation Yes
Overload Yes
Manual and static bypass Yes
Maintenance bypass Yes (without crossing)
RFI filter Yes
Battery charger protection Yes
Battery temperature compensation Yes
COMUNICATIONS
Local and remote TCP/IP, MÓDEM RTC ó GSM/GPRS
STANDARDS
Certificates CE Marking
European low voltage directive 73/23/CEE-93/68/CEE
OTHERS
Permitted relative humidity 0-85% (excluding battery)
Altitude without power reduction 2000 m.s.n.m.
Operation temperature 0-45ºC
Dimensions UPS (2)
WxHxD (mm)1210x640x2445 1620x640x2445 2435x640x2445 2435x640x2445 4870x640x2445
UPS Weight 650 950 1345 1575 2x1345+300
1
2
3 45
1
2
3
4
5
Specifications may be changed without notice.
GENERAL SPECIFICATIONS
Model Sena 48 V Sena 120 V
Reference 018700 018701 018702 018703 018704 018705
Power KVA 1 2 3 6 1 2
Total efficiency 88%
INPUT
AC input voltage 20 40 60 120 8 16
DC input voltage 43-57 110-145
OUTPUT
Voltage Vac 230 230
Voltage precision ± 2% ± 2%
Output frequency Hz 50 ± 0.5%
Type of wave Pure sinusoidal
Distortion THD <3%
PROTECTIONS
Output overload Yes
Shortcircuit Yes
Protection against overload 125% load for 60 sec; 150% load for 20 ms
Overload Yes
Manual bypass optional Consult dimensions
Low batttery Yes
INDICATORS
LED signalling Display LED que muestra el nivel de carga, nivel de battery, el estado de trabajoand el estado de funcionamiento del INVERSOR
Alarms Overload / Bypass / Fallo de inversor / Battery baja / Fallo de INVERSOR
COMUNICATIONS & SOFTWARE
Port RS232
Software UPSilon 2000
Dry contacts Yes
SNMP card (optional ) RS232 SNMP Ethernet converter
STANDARDS
Marks CE
Directives UNE-EN 50091-1UNE-EN 50091-2
OTHERS
Weight Kg 8.5 10.25 12 26 10 12
Dimensions UWxHxD (mm)
430x430x88 (2U) 430x430x88 (2U) 430x430x88 (2U) 230x635x685 430x430x88 (2U) 430x510x112 (2.5U)
w w w . z i g o r . c o m
UPSilon 2000
Clientmate
Nove
ll N
etw
are
Win
dow
s 98
Win
dow
s N
TW
indow
s 2000
Win
dow
s M
eW
indow
s XP
Win
dow
s 2003
Win
dow
s Vis
taW
indow
s 2008
Win
dow
s 7
Lin
ux
Debia
nR
edhat
Fedora
Suse
Ubuntu
Redfla
gM
AC
10.4
.5/1
0.5
.5Fre
eB
SD
VM
Ware
ESX/E
SXi
> Display on a web browser: Clientmate Monitors the status of the UPS submitting the IP address and provides a wide setting capacity.
> Features
SNMP card (Rhin +) IEC-2 schuko extension cable
STS 3 KVA PDU
Relay contact (Rhin +) SNMP card
SNMP card Allows the communication of the UPS with an agent via SNMP. RESTUPS
RHIN
PLUS
IEC-2 schuko extension cable
STS 3 KVA Bypass for automatic selection of two diferent AC inputs.Incorporate a communication port DB9 (Relé, 2A/250Vca) to monitor the status of the bypass.
PDU Power supply units.Smart PDUs in rack format to control, supervise and distribute the connected loads.
Manual bypass Allows manually to put loads on bypass and do a safety maintenance of the UPS.Easy installation.Terminals connection.
Relay contact Allows customise alarms by dry contacts.
Parallel kit Single-phase UPS parallel kit of the Rhin Plus series.
External rapid charger External charger for autonomy extensions.
TECHNICAL CONSULTING AND ANALYSIS
> Energetic audits of the installations
> Pre-sales consulting
> Units replacement analysis
> Technical training
TECHNICAL SUPPORT
> Technical support: at 945 290 360 and through the mail [email protected]
> Start up
> Corrective and preventive maintenance
> Batteries charge state
> Help phone service 24 h-365 days
> Customised attention by technical experts of Zigor Maintenance and Service department
SERVICES
> Maintenance contracts
> Warranty extensions personalised to customer needs
> Communication and managing systems: Upsilon 2000/Power Manager/Net Agent.
Control, supervision, monitoring and batteries (BACS II) maintenance
> Training courses
> Continous improvement proposals
> RMA processing through www.zigor.com website
>
METHODS
MP Preventive maintenance
MPCHCorrective-preventive maintenance with help phone service 24 hours at customer premises in case of the failure in 24 h at work hours from 8-18h from Monday to Friday
MPCSHCorrective-preventive maintenance with help phone service 24 hours at customer premises in case of the failure in 24 h at work hours from 8-18h from Monday to Sunday
> Service and Technical support: work areas
>
Visit www.zigor.com to get information about your closest technical service