23
Update on Quartz Plate Calorimetry Y. Onel HCAL GENERAL MEETING March 27, 2014 1

Update on Quartz Plate Calorimetry

  • Upload
    alyn

  • View
    29

  • Download
    0

Embed Size (px)

DESCRIPTION

Update on Quartz Plate Calorimetry. Y. Onel HCAL GENERAL MEETING March 27, 2014. HE Quartz Plate Upgrade Group: Iowa * , Baylor , Fairfield * , Fermilab * , FIU, Mississippi Trieste, Italy Bogazici U. Istanbul,Turkey Cukurova U, Adana, Turkey ITU, Istanbul, Turkey - PowerPoint PPT Presentation

Citation preview

Page 1: Update on Quartz Plate  Calorimetry

Update on Quartz Plate Calorimetry

Y. Onel

HCAL GENERAL MEETINGMarch 27, 2014

1

Page 2: Update on Quartz Plate  Calorimetry

2

HE Quartz Plate Upgrade Group:Iowa *, Baylor, Fairfield*, Fermilab*, FIU, MississippiTrieste, ItalyBogazici U. Istanbul,TurkeyCukurova U, Adana, TurkeyITU, Istanbul, TurkeyMETU,Ankara, TurkeyRio-CBPF,BrazilRio-UERJ,BrazilSao Paulo-Unicamp,Brazil* Lead GroupsExtended US Group for HCAL Upgrades:Boston, Minnesota, Princeton, Virginia, Notre Dame

Page 3: Update on Quartz Plate  Calorimetry

3

Quartz Plate and New WLS R&DWe would like to work towards fabricating and testing liquid scintillator/WLS capillaries, of which we have done many in the past. (For example, see pix below for liquid WLS filled capillaries, the fabrication of which included degassing capabilities).

We are also capable of producing novel quartz optically-cladded capillaries with soft scintillator (anthracene) and similar WLS materials (these films anneal rapidly and the radiation damage is minimal).

We have also proposed a simple mechanical scheme to replace periodically standard plastic WLS fibers. WLS fibers addressing the raddam issue are essential for reading out either new narrow scintillator tile fingers (Russian proposal), longer-wavelength scintillator tiles, liquid scintillator tiles, and/or Shashlik.

Page 4: Update on Quartz Plate  Calorimetry

4

• Examples of Liquid Fibers: Here are beautiful 2.5mm OD liquid WLS fibers(L), and as packaged to readout coated quartz plates (R)

• Soft scintillator-filled quartz cladding fibers. WLS would be similar. There are easy methods and commercial vendors to fill such capillaries.

Page 5: Update on Quartz Plate  Calorimetry

5

Quartz Capillaries tested in the TB

Page 6: Update on Quartz Plate  Calorimetry

6

Capillary Tubes Filled with AnthraceneCapillary Tubes perpendicular to the beam (400K-80 GeV e-)Readout by two miniPMTs at both ends.

Charge > 20 fC

Both charges > 20 fC

Beam

1125 fC ~ 7pe | 1593 fC ~ 10 pe

Page 7: Update on Quartz Plate  Calorimetry

7

The tendency is towards Quartz or Liquid tiles and radhard WLS with coated quartz fibers or quartz capilaries with anthracene or Randy's liquid.

Some members of my group are working with Randy on the Shaslik. Randy's liquid is more appropriate for Shaslik and not tested within a sealed capilary with Neutrons and protons yet. In fact we will include these raddam tests in our October CERN RADDAM PS schedule on the other hand we have a good alternatives as outlined in our original proposal.

Page 8: Update on Quartz Plate  Calorimetry

8

Fermilab T-1041 CollaborationT-1041 CMS Forward Calorimetry R&D Experiment

Spokespersons: Burak Bilki and Yasar Onel

Several groups under one umbrella. Strong collaboration!

Page 9: Update on Quartz Plate  Calorimetry

9

Fermilab T-1041 Collaboration

We are in test beam now!

Page 10: Update on Quartz Plate  Calorimetry

10

QP Results from T-1041 Nov 13 RunWe performed single MIP and shower response comparisons between:

- HE Tile

- Quartz plate with pTp coating on one side (PMT directly coupled)

- Two quartz plates with fibers in between and pTp coating on inner surfaces Sandwich pTp

120 GeV proton beam 8 GeV positron beam

~ 4.5 X0 steel

Page 11: Update on Quartz Plate  Calorimetry

11

QP Results from T-1041 Nov 13 RunMIP response

120 GeV proton beam

MIP through fiber

Single sided pTp peaks ~ 3 peHE tile response a factor of ~ 6 higher than sandwich pTp

Page 12: Update on Quartz Plate  Calorimetry

12

QP Results from T-1041 Nov 13 Runmuons

Sandwich pTp response a factor of ~ 3.5 higher than single side ptp coated plate, a factor of ~ 3.5 lower than the HE tile.

Mixed beam (muon, pions and positrons), pions are cleaned up using the quartz fiber tail catcher calorimeter.

Page 13: Update on Quartz Plate  Calorimetry

13

Projection to a Larger Scale PrototypeCMS-NOTE-2008-010

IEEE Transactions on Nuclear Science, Volume 57, Issue 2, 754-759, 2010

Quartz plate w/pTp prototypeDirect coupling of PMTsResponse to pions

Projected sandwich pTp prototype performance

Compare with the current HE performance

Leakage not taken care of

Page 14: Update on Quartz Plate  Calorimetry

14

Thin films of scintillator and/or on quartz tiles and fibers:

There are a number of options. EX: A sandwich made from few micron films of ZnO:Ga on 100 micron quartz tiles. These films are rad-hard. A sandwich of 7 layers of those tiles (i.e. less than 8mm thick) was tested with muons and produced a well-separated MIP peak with ~25% sE/E. In particular FNAL’s capabilities would be a great help for creating similar and more advanced stacks, sandwiches of WLS/scint films on thin quartz plates, quartz fibers and in & on quartz capillaries.

We also would very much like to go ahead with test beams of calorimeters using quartz-based tiles. But then parasitically also add scintillator tiles back-to-back, that between 3 groups could test the tile dual readout. MC estimates for the potential of tile-based Cerenkov Comp look very good, using the data from the few mm thick quartz plates we already tested. It would be a simple matter to add scintillator tiles between the absorbers, next to each quartz plate, and read them as 2 separate calorimeters – Q and Scint. Compared with fiber dual readout, a tile e-m front end using W plates would be far superior to the combined calorimeter, and capable of determining the e-m component of incident jets.

Page 15: Update on Quartz Plate  Calorimetry

15

There are critical Test Beams at FERMI and CERN, B. Bilki and Y. Onel are Co-PI's for both activities. Iowa group has already spent 68K and put in a great effort to start this TB effort and built some Quartz Plate Prototypes. (We have to get some of this money back since this was spent in FY14). We have a very good idea how to build new " Quartz Plates" and "New Radhard WLS" which we hope will produce a great results. Also we are in process of developing new wls rad-hard fibers.

There is an opportunity to test whatever prototype we can build until July and test at FERMI and until Mid-October at CERN and the RADDAM at FERMI and CERN PS by November 2014. We put in a great deal of money for the FERMI TB in FY2014 and we can get the right technology thru FERMI and CERN studies.

We booked 3 weeks at PS CERN RADDAM facility. We have to tests all of the components-- Quartz and Enchanced quartz related prototypes and new wls- rad-hard using our on-line system with protons, neutrons and gammas. This is also free facility and we have made our arrangements.

Page 16: Update on Quartz Plate  Calorimetry

16

Fiber ModelAll the details can be found at “Quartz Plate Calorimeter Prototype With Wavelength Shifting Fibers”,

Journal of Instrumentation, JINST_002P_0412, 2012.

Saint-Gobain (UV-Absorbing Blue Emitting) Scintillating Fiber, good up to 5 MRad (Busjan et al 1999 papers)

1 mm diameter fibers inserted into 9 grooves in quartz plates. This model was based on our precious study:

“CMS Hadronic EndCap Calorimeter Upgrade Studies for SLHC - Cerenkov Light Collection from Quartz Plates” ,

IEEE Transactions on Nuclear Science, Vol 55, Issue 2, 734-740, 2008.

Test fiber

Page 17: Update on Quartz Plate  Calorimetry

WLS Fibers in QuartzCerenkov light collection inside the quartz is

feasible with UV absorbing WLS fibersF. Duru et al. “CMS Hadronic EndCap Calorimeter Upgrade Studies for SLHC -

Cerenkov LightCollection from Quartz Plates” , IEEE Transactions on Nuclear Science, Vol

55, Issue 2, 734-740, 2008.

17

Page 18: Update on Quartz Plate  Calorimetry

18

Covering Quartz Plates with pTp

We evaporated PTP over quartz plates

Page 19: Update on Quartz Plate  Calorimetry

Quartz Plates with PTP

19

PTP evaporation setup, and quartz plate holder

Page 20: Update on Quartz Plate  Calorimetry

PTP ModelAll details can be found at: "CMS Hadronic EndCap

Calorimeter Upgrade Studies for SLHC Pterphenyl Deposited Quartz Plate Calorimeter Prototype",

IEEE Transactions on Nuclear Science, Volume 57, Issue 2, 754-759, 2010.

2 micron thickness of P-Terphenyl was evaporated on quartz plates in vacuum chambers.

We showed that same result can also be obtained By RF sputtering ZnO on quartz

Page 21: Update on Quartz Plate  Calorimetry

7 layer 700 micron ZnO plate

21

- We have deposited 0.2 micron ZnO (%4 Ga) to “100 micron” thick quartz plates.- This sandwich structure with 0.7 mm total thickness is placed in an aluminum frame and tested for mips on this test beam for the first time. - We got very promising results, for both pion and electron beams. We need to work on this technique to develop future “radiation hard scintillators”.

Page 22: Update on Quartz Plate  Calorimetry

22

Things to do

• Produce at least 2 each 8 mm Quartz Plates made of 100 micron QP’s coated and made as a stack with ZnO-Ga and pTp

• Produce at least 2 Quart based tiles and add Scintillator tiles back to back to read as Dual Tile readout (C and Scint. simultaneous readout).

• Produce radhard WLS namely 1) quartz fiber coated- sputtering with a) pTp b) Zno-Ga 2) quartz capillaries filled by anthracene and Randy’s liquid.

• If funding is available we will produce about 20 coated Quartz 8mm stacks to build a small calorimetry.

• CRUCIAL is the TB at FERMI AND CERN. Everything is already scheduled during next two years.

• Crucial is the CERN Irrad which we scheduled for November 2014. We will irradiate on-line all our components and system with Neutrons, Proton and Gammas. Without these tests the HE options would not be viable.

Page 23: Update on Quartz Plate  Calorimetry

23

Conclusions

Quartz plate calorimetry still proves to be a viable option.

Radiation hardness in the expense of calorimetric performance.

Several techniques already proven to improve the light output are in hand.

Rigorous R&D ideas awaiting future funding.

Considerable amount of work/ideas on fiber development possible (upon funding)

Quartz plate calorimetry is the optimal solution for the first 1-2 λ of HE and for the 2 highest-η towers with no comparable alternatives.