871 872 873 874 875 19 27 35 20 26 34 25 33 18 39 24 30 32 17 38 23 31 13 14 15 9 5 6 10 7 11 816 812 808 1 2 3 4 821 36 28 822 829 837 843 41 40 842 45 45 46 48 52 49 53 50 54 847 851 855 56 57 58 59 4 UP UP UP UP UP UP UP UP UP UP SLOPE TO BE 1:12 MAX RAMP DOWN F.F.E. 7.99' F.F.E. 10.05' F.F.E. 10.05' 871 872 873 874 875 19 27 35 20 26 34 25 33 18 39 24 30 32 17 38 23 31 13 14 15 9 5 6 10 7 11 816 812 808 1 2 3 4 821 36 28 822 829 837 843 41 40 842 45 45 46 48 52 49 53 50 54 847 851 855 56 57 58 59 4 UP UP UP UP UP UP UP UP UP UP SLOPE TO BE 1:12 MAX RAMP DOWN F.F.E. 7.99' F.F.E. 10.05' F.F.E. 10.05' 2 E-222.00 52 53 56 57 52 53 56 57 CPB 1 M M 3 M SEE NOTE 6, 7, 9 & 10 NEW 100A 3 PHASE LIGHTING PANEL. LP8 2 SEE NOTE 6, 7, 9 & 10 EXISTING METER AT 55" AFF TO REMAIN PANEL BOARD AT 40" AFF TO REMAIN PANEL BOARD AT 40" AFF TO REMAIN SEE NOTE 4 PANEL AT 52" AFF TO REMAIN PANEL AT 41" AFF TO REMAIN TIMER PANEL AT 43" AFF TO REMAIN. NEW 400A 3P DIST. PANEL A NEW 400A 3P DIST. PANEL B NEW LOCATION FOR METER T.R.E. EXISTING PANEL BOARD AT 52" AFF NEW PULL BOX NEW 600A 3 POLES DISC. SW NEW COMM PULL BOX MTD AT CEILING 30A DISCONNECT SWITCHES AT >36" TO REMAIN (3) SETS OF 4-500 KCMIL CABLES -4"C INCOMING SERVICE FROM PSE&G GRID SYSTEM. REFER TO SITE PLAN DWG. E-311 1 2 3 4 5 6 7 7 3 2 1 654 3 E-222.00 CONDUIT SHALL BE PVC CONDUIT EMBEDDED IN 3" CONCRETE ENVELOPE COMM CTR ATS NEW COMM CTR METER 8 8 MDP B MDP A EXISTING LOAD SEE NOTE 7&9 PULLBOX SEE E-108 NOTES 7&8 EXISTING PULL BOX 1 1 3 SEE PANEL SCHEDULE TO CONNECT TO EXISTING LOAD. SEE NOTES 4,5, 6,7&9 SEE NOTES 6&9 EXISTING 250A PANELBOARD - HLP SEE NOTE 10 NEW NEW SEE NOTES 7 EXISTING CONDUIT AND WIRING TO BE REUSED M EXISTING LOCAL METER 1 4 CONDUIT & WIRING 2 NEW 600A, 3 POLES DISCONNECT SWITCH TO BE INSTALLED AT MIN 36" AFF. SEE DRAWING E-408.00 FOR CONTINUATION NEW POWER PULL BOX 2 RELOCATED METER T.R.E NEW AND/OR EXISTING CONDUIT AND WIRING SEE NOTE 6, 7 & 9 NEW 100A 3 PHASE LIGHTING PANEL. LP8 NEW COMM. PULL BOX 5 NEW 4#500 KCMIL +1#1/0 G IN 4"C (CEILING SUPPORTED) NEW 2 SETS OF 4#500 KCMIL +1#1/0 G IN 4"C NEW #16AWG/4 TRIAD SHIELDED CABLE IN 1 1 2 " CONDUIT TO TOTALIZING RELAY ENCLOSURE CONDUIT AND CABLE FROM METER. CONTRACTOR TO DETERMINE SOURCE/LOAD CONNECTION AND MAINTAIN SAME CONNECTION. 1 2 3 4 NEW 4#2, 1#8G IN 1 1/2"C. SEE DWG. E-621 FOR CIRCUIT CONNECTION 5 56 56 CPB 1.5" 1 2 3 4 5 6 7 7 7 6 4 5 3 2 1 654 OPEN END CONDUIT FOR DRAIN (TYP) UNDER GROUND CONCRETE PULL BOX WITH STEEL COVER. (TYP) 8 8 8 NOTES: 1 E-222.00 KEY PLAN - BUILDING No. 8 SCALE: 1/16"=1'-0" 2 E-222.00 ELECTRICAL EQUIPMENT FIRST FLOOR PLAN - BUILDING No. 8 SCALE: 3/4"=1'-0" N N 1. FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS SEE DRAWING E-001.00. 2. INSTALL NEW EQUIPMENT 6" ABOVE SLR. FOR SLR INFORMATION, SEE DRAWING E-608.00. 3. FOR CONSTRUCTION PHASING SEE DRAWING E-004.00. 4. INSTALL NEW CONDUITS AND CABLE EXTENSIONS FOR SUB FEEDER CABLES, FROM NEW PULLBOX TO NEW MDPs. SEE E-608.00 FOR SCHEDULE OF MDPs. 5. EXISTING BRANCH FEEDERS SHALL BE EXTENDED INTO THE PULL BOX AND SPLICED WITH NEW EXTENDED CABLES FROM THE NEW MDP'S. 6. FOR EQUIPMENT IN THE ELECTRICAL ROOM SERVED DIRECTLY FROM THE MDP, INSTALL NEW CONDUITS AND WIRING FROM EQUIPMENT TO NEW MDPs (WHERE EXISTING CONDUIT AND WIRING ARE NOT ADEQUATE). ALLOW A MAXIMUM OF 100FEET OF CONDUIT AND WIRING PER EQUIPMENT AFFECTED. OWNER SHALL BE CREDITED FOR EXCESS CONDUIT AND WIRING NOT USED. CONDUIT AND CABLE SHALL BE SIZED TO MATCH EXISTING CONDITIONS. 7. FOR EQUIPMENT SERVED FROM OTHER LOCAL PANEL BOARDS, AND AFFECTED BY RELOCATION, INSTALL NEW BRANCH CIRCUIT CONDUIT AND WIRING IF EXISTING CONDUIT AND WIRING ARE NOT ADEQUATE. ALLOW A MAXIMUM OF100FEET OF CONDUIT AND WIRING PER EQUIPMENT AFFECTED. OWNER SHALL BE CREDITED FOR CONDUIT AND WIRING NOT USED. CONDUIT AND CABLE SHALL BE SIZED TO MATCH EXISTING CONDITIONS. 8. PULL BOX SHALL BE SIZED TO MATCH REQUIRED CODE AND INSTALLED 29.4" AFF. PULL BOX SHALL BE USED FOR APARTMENT RISER. 9. CONTRACTOR SHALL BE RESPONSIBLE TO DETERMINE THE CORRECT CONNECTION OF EVERY EQUIPMENT IN THE ELECTRICAL ROOM, AND ENSURE THAT FINAL CONNECTION MATCH APPROPRIATELY. 10. NEW CABLE SHALL BE SPLICED TO EXISTING CABLE IN THE ENCLOSURE, AND SHIELDED APPROPRIATELY. 11. CONNECT ALL EQUIPMENT (NEW AND EXISTING) TO EXISTING GROUND AS PER NEC STANDARDS. 12. PROVIDE 2 # 10 + 1 #12G IN 3 4 " C FROM EACH CIRCUIT TO CCTV SECURITY SYSTEM (SEE NOTE-2 & 3 SERIES SE-100.00 DRAWINGS) AS PER E-600 SERIES DRAWINGS AND ARE FOR LOCATION OF CCTV SYSTEM OF SE-100 SERIES DRAWINGS. 13. PROVIDE GROUNDING BUS BAR AS PER NEC. FOR COORDINATION, SEE DRAWINGS SE-100 SERIES DRAWINGS FOR EXACT LOCATION. 14. 2"C FOR SCADA TERMINATES INSIDE CPB. JOHN LOPEZ AMIT GULERIA AS SHOWN BUILDING #8 3 E-222.00 CONDUIT SHAFT LAYOUT DETAIL SCALE: 1"=1'-0" Key/Location Plan Drawing Title: Contract No.: Drawing No.: Scale: Date: Checked By: Drawn By: Seal & Signature: Contract Title: - Sheet of TEL.(212)290-1444 FAX.(212)290-1425 48 West 37th St. New York, NY 10018 BEACH 82ND ST. BEACH 83TH ST. BEACH 84TH ST. BEACH 85TH ST. BEACH 85TH ST. BEACH 84TH ST. BEACH 83TH ST. BEACH 82ND ST. R O C K W A Y B E A C H B O U L E V A R D BEACH 86TH ST. BEACH 81ST ST. H A M M E L B O U L E V A R D HAMMEL BOULEVARD 12 10 11 5 13 14 9 3 6 7 1 4 2 8 Block No.: E.D.P. No.: Development No.: Zone No.: Lot No.: Zoning Map No.: Development: Building Address: Building No.(s): Borough of: ORACLE No.: LANGAN 21 Penn Plaza, Eighth Floor New York, NY 10001 TEL: (212) 479-5400 FAX: (212) 479-5444 AG CONSULTING ENGINEERING, PC 131 West 33rd Street, Suite 12B New York, NY 10001 TEL: (212) 268-0950 CONSTRUCTION PERMIT SERVICES 63 W 38th St #15, New York, NY 10018 TEL: (212) 246-5111 J. MARTIN 8 Armour Rd, Mahwah, NJ 07430 TEL: (201) 529-5585 CAMERON ENGINEERING 45 W 36th St, New York, NY 10018 TEL: (212) 324-4000 COSENTINI ASSOCIATES 2 Pennsylvania Plaza, New York, NY 10121 TEL: (212) 615-3600 32 Broadway, Eighth Floor New York, NY 10004 TEL: (212) 971-0936 SHEN MILSOM WILKE 417 5th Ave, New York, NY 10016 TEL: (212) 725-6800 HOWARD L. ZIMMERMAN ARCHITECTS, PC 11 West 30th Street, New York, NY 10001 TEL: (212) 564-9393 Consultants: ELLANA TEL. 212.306.4247 FAX 212.306.8542 PROGRAM UNIT: 166 53 KEY NOTES: 1 7 4 5 6 4x#500KCMIL IN 4"C FROM PSE&G TRANSFORMER TO ROOF ELECTRICAL ROOM. 4x#500KCMIL,1# 1/0G AWG IN 4"C FROM ROOF ELECTRICAL ROOM TO FIRST FLOOR ELECT. ROOM 4" CONDUIT SPARE 2" C FOR SCADA 1 1 2 " C FOR CAT 6 CABLES 1 1 2 " C FOR METER TOTALIZING SYSTEM 4x#500KCMIL,1# 1/0G AWG IN 4"C FROM ROOF ELECTRICAL ROOM TO FIRST FLOOR ELECT. ROOM 2 3 1 1 2 " C FOR FIRE ALARM CONTROL PANEL SEE DWG. E-704 FOR MORE DETAILS CONDUIT LEGEND: 8 3 4 " C FOR FIRE ALARM CONTROL PANEL FROM 3P, 30A TRANSFER SWITCH 4 E-222.00 ELECTRICAL ONE LINE DIAGRAM N.T.S 03/08/2018

UP 56 - eshare.nycha.info Management RFP Documents... · new comm ctr meter 8 8 mdp b mdp a ... system of se-100 series drawings. ... pse&g transformer to roof electrical room

Embed Size (px)

Citation preview

871872873874875

19

2735

20

2634

2533

1839

243032

1738 2331

13

14

15

9 5

610

711

816 812 808

1

2

3

4821

36 28

822829837843

41

40

842

45

45

46

4852

4953

5054

847851855

56

57

58

59 4

UPUP

UP

UP

UP

UP

UP

UP

UPUP

SLOPE TO BE 1:12 MAXRAMP DOWN

F.F.E. 7.99'

F.F.E. 10.05'

F.F.E. 10.05'

871872873874875

19

2735

20

2634

2533

1839

243032

1738 2331

13

14

15

9 5

610

711

816 812 808

1

2

3

4821

36 28

822829837843

41

40

842

45

45

46

4852

4953

5054

847851855

56

57

58

59 4

UPUP

UP

UP

UP

UP

UP

UP

UPUP

SLOPE TO BE 1:12 MAXRAMP DOWN

F.F.E. 7.99'

F.F.E. 10.05'

F.F.E. 10.05'

2

E-222.00

52

53

56

57

52

53

56

57

CP

B

1

M

M

3

M

SEE NOTE

6, 7, 9 & 10

NEW 100A 3 PHASE

LIGHTING PANEL. LP8

2

SEE NOTE

6, 7, 9 & 10

EXISTING METER

AT 55" AFF TO

REMAIN

PANEL BOARD AT

40" AFF TO REMAIN

PANEL BOARD AT

40" AFF TO REMAIN

SEE NOTE 4

PANEL AT 52" AFF

TO REMAIN

PANEL AT 41" AFF

TO REMAIN

TIMER PANEL AT

43" AFF TO REMAIN.

NEW 400A 3P DIST.

PANEL A

NEW 400A

3P DIST.

PANEL B

NEW LOCATION

FOR METER T.R.E.

EXISTING PANEL

BOARD AT 52" AFF

NEW PULL BOX

NEW 600A 3

POLES DISC. SW

NEW COMM

PULL BOX MTD

AT CEILING

30A DISCONNECT

SWITCHES AT >36"

TO REMAIN

(3) SETS OF 4-500 KCMIL CABLES -4"C

INCOMING SERVICE FROM PSE&G GRID

SYSTEM. REFER TO SITE PLAN DWG. E-311

123

456

7

7 3 2 1

6 5 4

3

E-222.00

CONDUIT SHALL BE PVC

CONDUIT EMBEDDED IN 3"

CONCRETE ENVELOPE

COMM CTR

ATS

NEW COMM CTR

METER

8

8

MDP B

MDP A

EXISTING LOAD

SEE NOTE 7&9

PULLBOX

SEE E-108 NOTES 7&8

EXISTING PULL BOX

1 1

3

SEE PANEL SCHEDULE TO

CONNECT TO EXISTING LOAD.

SEE NOTES 4,5, 6,7&9

SEE NOTES 6&9

EXISTING 250A

PANELBOARD - HLP

SEE NOTE 10

NEW NEW

SEE NOTES 7

EXISTING

CONDUIT AND

WIRING TO BE

REUSED

M

EXISTING LOCAL

METER 1

4

CONDUIT & WIRING

2

NEW 600A, 3 POLES

DISCONNECT

SWITCH TO BE

INSTALLED AT MIN

36" AFF.

SEE DRAWING E-408.00

FOR CONTINUATION

NEW POWER

PULL BOX

2

RELOCATED

METER

T.R.E

NEW AND/OR

EXISTING CONDUIT

AND WIRING SEE

NOTE 6, 7 & 9

NEW 100A 3 PHASE

LIGHTING PANEL.

LP8

NEW COMM.

PULL BOX

5

NEW 4#500 KCMIL +1#1/0 G IN 4"C (CEILING

SUPPORTED)

NEW 2 SETS OF 4#500 KCMIL +1#1/0 G IN 4"C

NEW #16AWG/4 TRIAD SHIELDED CABLE IN 1

1

2

"

CONDUIT TO TOTALIZING RELAY ENCLOSURE

CONDUIT AND CABLE FROM METER.

CONTRACTOR TO DETERMINE SOURCE/LOAD

CONNECTION AND MAINTAIN SAME

CONNECTION.

1

2

3

4

NEW 4#2, 1#8G IN 1 1/2"C. SEE DWG.

E-621 FOR CIRCUIT CONNECTION

5

5656

CP

B

1.5

"

123

456

7

7

7

6

4

5

3 2 1

6 5 4

OPEN END

CONDUIT FOR

DRAIN (TYP)

UNDER GROUND

CONCRETE PULL BOX

WITH STEEL COVER.

(TYP)

8

8

8

NOTES:

1

E-222.00

KEY PLAN - BUILDING No. 8

SCALE: 1/16"=1'-0"

2

E-222.00

ELECTRICAL EQUIPMENT FIRST FLOOR PLAN - BUILDING No. 8

SCALE: 3/4"=1'-0"

N

N

1. FOR GENERAL NOTES, SYMBOLS AND

ABBREVIATIONS SEE DRAWING E-001.00.

2. INSTALL NEW EQUIPMENT 6" ABOVE SLR. FOR SLR

INFORMATION, SEE DRAWING E-608.00.

3. FOR CONSTRUCTION PHASING SEE DRAWING

E-004.00.

4. INSTALL NEW CONDUITS AND CABLE EXTENSIONS

FOR SUB FEEDER CABLES, FROM NEW PULLBOX TO

NEW MDPs. SEE E-608.00 FOR SCHEDULE OF MDPs.

5. EXISTING BRANCH FEEDERS SHALL BE EXTENDED

INTO THE PULL BOX AND SPLICED WITH NEW

EXTENDED CABLES FROM THE NEW MDP'S.

6. FOR EQUIPMENT IN THE ELECTRICAL ROOM SERVED

DIRECTLY FROM THE MDP, INSTALL NEW CONDUITS

AND WIRING FROM EQUIPMENT TO NEW MDPs

(WHERE EXISTING CONDUIT AND WIRING ARE NOT

ADEQUATE). ALLOW A MAXIMUM OF 100FEET OF

CONDUIT AND WIRING PER EQUIPMENT AFFECTED.

OWNER SHALL BE CREDITED FOR EXCESS CONDUIT

AND WIRING NOT USED. CONDUIT AND CABLE SHALL

BE SIZED TO MATCH EXISTING CONDITIONS.

7. FOR EQUIPMENT SERVED FROM OTHER LOCAL

PANEL BOARDS, AND AFFECTED BY RELOCATION,

INSTALL NEW BRANCH CIRCUIT CONDUIT AND

WIRING IF EXISTING CONDUIT AND WIRING ARE NOT

ADEQUATE. ALLOW A MAXIMUM OF100FEET OF

CONDUIT AND WIRING PER EQUIPMENT AFFECTED.

OWNER SHALL BE CREDITED FOR CONDUIT AND

WIRING NOT USED. CONDUIT AND CABLE SHALL BE

SIZED TO MATCH EXISTING CONDITIONS.

8. PULL BOX SHALL BE SIZED TO MATCH REQUIRED

CODE AND INSTALLED 29.4" AFF.

PULL BOX SHALL BE USED FOR APARTMENT RISER.

9. CONTRACTOR SHALL BE RESPONSIBLE TO

DETERMINE THE CORRECT CONNECTION OF EVERY

EQUIPMENT IN THE ELECTRICAL ROOM, AND ENSURE

THAT FINAL CONNECTION MATCH APPROPRIATELY.

10. NEW CABLE SHALL BE SPLICED TO EXISTING CABLE

IN THE ENCLOSURE, AND SHIELDED APPROPRIATELY.

11. CONNECT ALL EQUIPMENT (NEW AND EXISTING) TO

EXISTING GROUND AS PER NEC STANDARDS.

12. PROVIDE 2 # 10 + 1 #12G IN

3

4

" C FROM EACH CIRCUIT

TO CCTV SECURITY SYSTEM (SEE NOTE-2 & 3 SERIES

SE-100.00 DRAWINGS) AS PER E-600 SERIES

DRAWINGS AND ARE FOR LOCATION OF CCTV

SYSTEM OF SE-100 SERIES DRAWINGS.

13. PROVIDE GROUNDING BUS BAR AS PER NEC. FOR

COORDINATION, SEE DRAWINGS SE-100 SERIES

DRAWINGS FOR EXACT LOCATION.

14. 2"C FOR SCADA TERMINATES INSIDE CPB.

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #8

3

E-222.00

CONDUIT SHAFT LAYOUT DETAIL

SCALE: 1"=1'-0"

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

16653

KEY NOTES:

1

7

4

5

6

4x#500KCMIL IN 4"C FROM

PSE&G TRANSFORMER TO

ROOF ELECTRICAL ROOM.

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

4" CONDUIT SPARE

2" C FOR SCADA

1

1

2

" C FOR CAT 6 CABLES

1

1

2

" C FOR METER TOTALIZING

SYSTEM

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

2

3

1

1

2

" C FOR FIRE ALARM CONTROL

PANEL

SEE DWG. E-704 FOR MORE DETAILS

CONDUIT LEGEND:

8

3

4

" C FOR FIRE ALARM CONTROL

PANEL FROM 3P, 30A TRANSFER

SWITCH

4

E-222.00

ELECTRICAL ONE LINE DIAGRAM

N.T.S

03/08/2018

2

E-223.00

7 1511

106 14

34

35

19

33

20

25

39

32

27

24

23

18

38

13

31

5

15

12

7

30

17

11

10

1

6

3

29 37

21 42

40

46

52

49 53

50 54

47 51 55

56

57

58

59

26

14

9

164

36

22 43

45

28

8

2

41

45 48

UP

UP

UP

UP

UP

UP

F.F.E. 8.54'

F.F.E. 10.65'

F.F.E. 10.65'

7 1511

106 14

34

35

19

33

20

25

39

32

27

24

23

18

38

13

31

5

15

12

7

30

17

11

10

1

6

3

29 37

21 42

40

46

52

49 53

50 54

47 51 55

56

57

58

59

26

14

9

164

36

22 43

45

28

8

2

41

45 48

UP

UP

UP

UP

UP

UP

F.F.E. 8.54'

F.F.E. 10.65'

F.F.E. 10.65'

54

55

58

59

UP

EXISTING EQUIPMENT

AT >22" AFF

1

3

EXISTING 250A

PANEL BOARD

AT 33" AFF

CP

B

2

SEE NOTE 6 & 7

SEE NOTE 4

SEE NOTE 6 & 7

DISCONNECT

SWITCH AT 43"

AFF

EXISTING 30A

DISC. SW

SEE NOTE 6 & 7

NEW 400A 3P

MAIN DIST

PANEL A

NEW 400A 3P

MAIN DIST

PANEL B

NEW

LOCATION

FOR EXISTING

METER T.R.E

NEW

LOCATION

FOR DISC. SW

(AT 23" AFF)

INSTALLED AT

>29" AFF

DISC. SW AT

NEW HEIGHT

44" AFF

NEW LOCATION

FOR DISC. SW TO

BE INSTALLED AT

MIN 29" AFF

SEE NOTE 4

SEE NOTE 6&7

NEW PULL

BOX

NEW POWER

PULL BOX MTD

AT CEILING

SEE NOTE 8

EXISTING

LOCAL METER

1 AT 42.5" AFF

NEW COMM

PULL BOX MTD

AT CEILING SEE

NOTES 8 & 12

NEW 600A

3 POLES

DISC SW

NEW 100A

3 PHASE

LIGHTING

PANEL.

LP9

(3) SETS OF 4-500 KCMIL

CABLES - 4"C. INCOMING

SERVICE FROM PSE&G

GRID SYSTEM. REFER TO

SITE PLAN DWG. E-312

1

1

2 3

4 5 6

7

2 3 7

654

3

E-223.00

CONDUIT SHALL BE PVC

CONDUIT EMBEDDED IN 3"

CONCRETE ENVELOPE

54

55

58

59

UP

8

8

1

NEW 4#500 KCMIL +1#1/0 G IN 4"C

(CEILING SUPPORTED)

2 SETS 4#500 KCMIL +1#1/0 G IN 4"C

NEW #16AWG/4 TRIAD SHIELDED

CABLE IN 1

1

2

" CONDUIT TO

TOTALIZING RELAY ENCLOSURE

CONDUIT AND CABLE FROM

METER. CONTRACTOR TO

DETERMINE SOURCE/LOAD

CONNECTION AND MAINTAIN SAME

CONNECTION.

2

3

4

NEW 4#2, 1#8G IN 1 1/2"C. SEE DWG.

E-622 FOR CIRCUIT CONNECTION

5

1 1

SEE PANEL SCHEDULE TO

CONNECT TO EXISTING LOAD.

SEE NOTES 4,5, 6,7&9

EXISTING 250A

PANELBOARD - HLP

M

EXISTING LOCAL

METER 1

4

3

EXISTING CONDUIT

AND WIRING TO BE

REUSED

NEW

MDP A

NEW

MDP B

RELOCATED METER

T.R.E. SEE NOTE 10

NEW PULL BOX

SEE NOTE 8

PULLBOX

SEE E-109 NOTES 7&8

SEE NOTES 6&9

SEE NOTE 7

EXISTING LOAD

SEE NOTES 7&9

NEW AND/OR EXISTING

CONDUIT AND WIRING

SEE NOTES 6, 7 & 9

NEW 100A 3 PHASE

LIGHTING PANEL. LP9

2

NEW 600A, 3 POLES

DISCONNECT SWITCH

TO BE INSTALLED AT

MIN 36" AFF.

SEE DRAWING E-409.00

FOR CONTINUATION

NEW POWER

PULL BOX

2

NEW COMM.

PULL BOX

5

59CP

B

1.5"

1

1

2 3

4 5 6

7

2 3 7

654

OPEN END

CONDUIT FOR

DRAIN (TYP)

UNDER GROUND

CONCRETE PULL BOX

WITH STEEL COVER.

(TYP)

59

8

8

1

E-223.00

KEY PLAN - BUILDING No. 9

SCALE:1/16"=1'-0"

2

E-223.00

ELECTRICAL EQUIPMENT FIRST FLOOR PLAN - BUILDING No. 9

SCALE: 3/4"=1'-0"

N

N

NOTES:

1. FOR GENERAL NOTES, SYMBOLS AND

ABBREVIATIONS SEE DRAWING E-001.00.

2. INSTALL NEW EQUIPMENT 6" ABOVE SLR. FOR SLR

INFORMATION, SEE DRAWING E-609.00.

3. FOR CONSTRUCTION PHASING SEE DRAWING

E-004.00.

4. INSTALL NEW CONDUITS AND CABLE EXTENSIONS

FOR SUB FEEDER CABLES, FROM NEW PULLBOX

TO NEW MDPs. SEE E-609.00 FOR SCHEDULE OF

MDPs.

5. EXISTING BRANCH FEEDERS SHALL BE EXTENDED

INTO THE PULL BOX AND SPLICED WITH NEW

EXTENDED CABLES FROM THE NEW MDP'S.

6. FOR EQUIPMENT IN THE ELECTRICAL ROOM

SERVED DIRECTLY FROM THE MDP, INSTALL NEW

CONDUITS AND WIRING FROM EQUIPMENT TO NEW

MDPs (WHERE EXISTING CONDUIT AND WIRING

ARE NOT ADEQUATE). ALLOW A MAXIMUM OF

100FEET OF CONDUIT AND WIRING PER

EQUIPMENT AFFECTED. OWNER SHALL BE

CREDITED FOR EXCESS CONDUIT AND WIRING

NOT USED. CONDUIT AND CABLE SHALL BE SIZED

TO MATCH EXISTING CONDITIONS.

7. FOR EQUIPMENT SERVED FROM OTHER LOCAL

PANEL BOARDS, AND AFFECTED BY RELOCATION,

INSTALL NEW BRANCH CIRCUIT CONDUIT AND

WIRING IF EXISTING CONDUIT AND WIRING ARE

NOT ADEQUATE. ALLOW A MAXIMUM OF100FEET

OF CONDUIT AND WIRING PER EQUIPMENT

AFFECTED. OWNER SHALL BE CREDITED FOR

CONDUIT AND WIRING NOT USED. CONDUIT AND

CABLE SHALL BE SIZED TO MATCH EXISTING

CONDITIONS.

8. PULL BOX SHALL BE SIZED TO MATCH REQUIRED

CODE AND INSTALLED AT CEILING AFF. PULL BOX

SHALL BE USED FOR APARTMENT RISER.

9. CONTRACTOR SHALL BE RESPONSIBLE TO

DETERMINE THE CORRECT CONNECTION OF

EVERY EQUIPMENT IN THE ELECTRICAL ROOM,

AND ENSURE THAT FINAL CONNECTION MATCH

APPROPRIATELY.

10. NEW CABLE SHALL BE SPLICED TO EXISTING

CABLE IN THE ENCLOSURE, AND SHIELDED

APPROPRIATELY.

11. CONNECT ALL EQUIPMENT (NEW AND EXISTING)

TO EXISTING GROUND AS PER NEC STANDARDS.

12. 2"C FOR SCADA TERMINATES INSIDE CPB.

13. PROVIDE 2 # 10 + 1 #12G IN

3

4

" C FROM EACH

CIRCUIT TO CCTV SECURITY SYSTEM (SEE NOTE-2

& 3 SERIES SE-100.00 DRAWINGS) AS PER E-600

SERIES DRAWINGS AND ARE FOR LOCATION OF

CCTV SYSTEM OF SE-100 SERIES DRAWINGS.

14. PROVIDE GROUNDING BUS BAR AS PER NEC. FOR

COORDINATION, SEE DRAWINGS SE-100 SERIES

DRAWINGS FOR EXACT LOCATION.

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #9

3

E-223.00

CONDUIT SHAFT LAYOUT DETAIL

SCALE: 1"=1'-0"

N

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

16656

KEY NOTES:

1

7

4

5

6

4x#500KCMIL IN 4"C FROM

PSE&G TRANSFORMER TO

ROOF ELECTRICAL ROOM.

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

4" CONDUIT SPARE

2" C FOR SCADA

1

1

2

" C FOR CAT 6 CABLES

1

1

2

" C FOR METER TOTALIZING

SYSTEM

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

2

3

1

1

2

" C FOR FIRE ALARM CONTROL

PANEL

SEE DWG. E-704 FOR MORE DETAILS

CONDUIT LEGEND:

8

3

4

" C FOR FIRE ALARM CONTROL

PANEL FROM 3P, 30A TRANSFER

SWITCH

4

E-223.00

ELECTRICAL ONE LINE DIAGRAM

N.T.S

03/08/2018

2

E-224.00

UP

UP

34

35

19

33

20

25

39

32

27

24

23

18

38

13

31

5

7 15

12

17

11

30

10

1

3

6

2

8

29 37

21 42

40

46

52

49 53

50 54

47 51 55

56

57

58

59

26

14

9

36

4

28

22

16

41

45

4845

43

UP

UP

UP

UP

UP

UP

F.F.E. 9.04'

F.F.E. 11.10'

F.F.E. 11.10'

UP

UP

34

35

19

33

20

25

39

32

27

24

23

18

38

13

31

5

7 15

12

17

11

30

10

1

3

6

2

8

29 37

21 42

40

46

52

49 53

50 54

47 51 55

56

57

58

59

26

14

9

36

4

28

22

16

41

45

4845

43

UP

UP

UP

UP

UP

UP

F.F.E. 9.04'

F.F.E. 11.10'

F.F.E. 11.10'

54

55

58

59

UP

NEW COMM PULL

BOX MTD AT CEILING

SEE NOTES 8 & 12

EXISTING

COMM. PANELS

M

EXISTING DISC. SW.

AT 40" AFF

EXISTING DISC.

SW. 24" AFF

2

SEE NOTE 4

EXISTING METER

T.R.E AT NEW

LOCATION

SEE NOTE 4

3

M

SEE NOTES 6, 7&9

SEE

NOTES

6&7

SEE

NOTES 6&7

SEE NOTES 6&7

NEW 400A 3P

MAIN DIST

PANEL B

NEW 400A 3P

MAIN DIST

PANEL A

EXISTING CEILING

MOUNTED PULL BOX

TO REMAIN.

CP

B

NEW POWER PULL

BOX MTD AT CEILING

SEE NOTE 8

NEW 600A 3 POLES

DISCONNECT SWITCH TO BE

INSTALLED AT >36" AFF.

NEW 100A 3 PHASE

LIGHTING PANEL. LP10

1

1

(3) SETS OF 4-500 KCMIL

CABLES - 4"C

INCOMING SERVICE FROM

PSE&G GRID SYSTEM. REFER

TO SITE PLAN DWG. E-312

1

1

23

4 5 6

7

2 3 7

654

3

E-224.00

CONDUIT SHALL BE PVC

CONDUIT EMBEDDED IN

3" CONCRETE ENVELOPE

54

55

58

59

UP

8

8

1

NEW 4#500 KCMIL +1#1/0 G IN 4"C

(CEILING SUPPORTED)

2 SETS 4#500 KCMIL +1#1/0 G IN 4"C

NEW #16AWG/4 TRIAD SHIELDED

CABLE IN 1

1

2

" CONDUIT TO

TOTALIZING RELAY ENCLOSURE

CONDUIT AND CABLE FROM

METER. CONTRACTOR TO

DETERMINE SOURCE/LOAD

CONNECTION AND MAINTAIN SAME

CONNECTION.

2

3

4

NEW 4#2, 1#8G IN 1 1/2"C. SEE DWG.

E-622 FOR CIRCUIT CONNECTION

5

1 1

SEE PANEL SCHEDULE TO

CONNECT TO EXISTING LOAD.

SEE NOTES 4,5, 6,7&9

EXISTING 250A

PANELBOARD - HLP

M

EXISTING

LOCAL

METER 1

4

3

EXISTING

CONDUIT AND

WIRING TO BE

REUSED

NEW POWER

PULL BOX

NEW

MDP A

NEW

MDP B

RELOCATED

METER T.R.E.

SEE NOTE 10

NEW PULL

BOX

SEE NOTE 8

PULLBOX

SEE E-110 NOTES 7&8

SEE NOTES 6&9

SEE NOTES 7

EXISTING LOAD

SEE NOTE 7&9

NEW AND/OR EXISTING

CONDUIT AND WIRING

SEE NOTE 6, 7 & 9

NEW 100A 3

PHASE LIGHTING

PANEL. LP10

2

NEW 600A, 3 POLES

DISCONNECT SWITCH

TO BE INSTALLED AT

MIN 36" AFF.

SEE DRAWING E-409.00

FOR CONTINUATION

2

NEW COMM.

PULL BOX

5

59

1.5

"

1

1

23

4 5 6

7

2 3 7

654

7

5

4

6

OPEN END

CONDUIT FOR

DRAIN (TYP)

UNDER GROUND

CONCRETE PULL

BOX WITH STEEL

COVER. (TYP)

59

8

8

1

E-224.00

KEY PLAN - BUILDING No. 10

SCALE: 1/16"=1'-0"

2

E-224.00

ELECTRICAL EQUIPMENT FIRST FLOOR PLAN - BUILDING No. 10

SCALE: 3/4"=1'-0"

N

N

NOTES:

1. FOR GENERAL NOTES, SYMBOLS AND

ABBREVIATIONS SEE DRAWING E-001.00.

2. INSTALL NEW EQUIPMENT 6" ABOVE SLR. FOR SLR

INFORMATION, SEE DRAWING E-610.00.

3. FOR CONSTRUCTION PHASING SEE DRAWING

E-004.00.

4. INSTALL NEW CONDUITS AND CABLE EXTENSIONS

FOR SUB FEEDER CABLES, FROM NEW PULLBOX

TO NEW MDPs. SEE E-610.00. FOR SCHEDULE OF

MDPs.

5. EXISTING BRANCH FEEDERS SHALL BE EXTENDED

INTO THE PULL BOX AND SPLICED WITH NEW

EXTENDED CABLES FROM THE NEW MDP'S.

6. FOR EQUIPMENT IN THE ELECTRICAL ROOM

SERVED DIRECTLY FROM THE MDP, INSTALL NEW

CONDUITS AND WIRING FROM EQUIPMENT TO NEW

MDPs (WHERE EXISTING CONDUIT AND WIRING

ARE NOT ADEQUATE). ALLOW A MAXIMUM OF

100FEET OF CONDUIT AND WIRING PER

EQUIPMENT AFFECTED. OWNER SHALL BE

CREDITED FOR EXCESS CONDUIT AND WIRING NOT

USED. CONDUIT AND CABLE SHALL BE SIZED TO

MATCH EXISTING CONDITIONS.

7. FOR EQUIPMENT SERVED FROM OTHER LOCAL

PANEL BOARDS, AND AFFECTED BY RELOCATION,

INSTALL NEW BRANCH CIRCUIT CONDUIT AND

WIRING IF EXISTING CONDUIT AND WIRING ARE

NOT ADEQUATE. ALLOW A MAXIMUM OF100FEET OF

CONDUIT AND WIRING PER EQUIPMENT AFFECTED.

OWNER SHALL BE CREDITED FOR CONDUIT AND

WIRING NOT USED. CONDUIT AND CABLE SHALL BE

SIZED TO MATCH EXISTING CONDITIONS.

8. PULL BOX SHALL BE SIZED TO MATCH REQUIRED

CODE AND INSTALLED ABOVE 16.8" AFF. PULL BOX

SHALL BE USED FOR APARTMENT RISER.

9. CONTRACTOR SHALL BE RESPONSIBLE TO

DETERMINE THE CORRECT CONNECTION OF

EVERY EQUIPMENT IN THE ELECTRICAL ROOM,

AND ENSURE THAT FINAL CONNECTION MATCH

APPROPRIATELY.

10. NEW CABLE SHALL BE SPLICED TO EXISTING

CABLE IN THE ENCLOSURE, AND SHIELDED

APPROPRIATELY.

11. CONNECT ALL EQUIPMENT (NEW AND EXISTING) TO

EXISTING GROUND AS PER NEC STANDARDS.

12. 2"C FOR SCADA TERMINATES INSIDE CPB.

13. PROVIDE 2 # 10 + 1 #12G IN

3

4

" C FROM EACH

CIRCUIT TO CCTV SECURITY SYSTEM (SEE NOTE-2

& 3 SERIES SE-100.00 DRAWINGS) AS PER E-600

SERIES DRAWINGS AND ARE FOR LOCATION OF

CCTV SYSTEM OF SE-100 SERIES DRAWINGS.

14. PROVIDE GROUNDING BUS BAR AS PER NEC. FOR

COORDINATION, SEE DRAWINGS SE-100 SERIES

DRAWINGS FOR EXACT LOCATION.

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #10

3

E-224.00

FEEDER CONDUIT SHAFT LAYOUT DETAIL

SCALE: 1"=1'-0"

N

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

16657

KEY NOTES:

1

7

4

5

6

4x#500KCMIL IN 4"C FROM

PSE&G TRANSFORMER TO

ROOF ELECTRICAL ROOM.

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

4" CONDUIT SPARE

2" C FOR SCADA

1

1

2

" C FOR CAT 6 CABLES

1

1

2

" C FOR METER TOTALIZING

SYSTEM

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

2

3

1

1

2

" C FOR FIRE ALARM CONTROL

PANEL

SEE DWG. E-704 FOR MORE DETAILS

CONDUIT LEGEND:

8

3

4

" C FOR FIRE ALARM CONTROL

PANEL FROM 3P, 30A TRANSFER

SWITCH

4

E-224.00

ELECTRICAL ONE LINE DIAGRAM

N.T.S

03/08/2018

52

53

56

57UP

EXISTING POWER

GUARD AT 60" AFF

EXISTING 20A CB AT 59"

AFF

EXISTING

30.5×24×10

BOX AT 48"

AFF

EXISTING TIMER

CLOCK AT 46" AFF

NEW PULL BOX

PB

M

PANELS AT 57" & 67"

AFF TO REMAIN

SEE NOTES 4

NEW 400A 3P 4W DIST.

PANEL B

SEE NOTE 4

NEW POWER PULL BOX

SEE NOTE 8

NEW 400A 3P 4W DIST.

PANEL A

3

EXISTING

METER T.R.E

EXISTING LOCAL

METER 1 AT NEW

HEIGHT >36" AFF

TIMER PANEL

AT 55" AFF

NEW COMM PULL

BOX MTD AT CEILING

SEE NOTE 8 & 12

SEE NOTE

6&7

SEE NOTE

6&7

SEE NOTES 6 & 7

EXISTING 24×24×8

BOX AT 48" AFF

CP

B

NEW 600A 3 POLES

DISCONNECT SWITCH

1

1

NEW 100 A, 3 PHASE

LIGHTING PANEL LP 11

EXISTING PANEL

BOARD AT 38" AFF

EXISTING 30A DISC.

SW. AT 28" AFF

REPLACED AT MIN.

36" AFF

EXISTING 30A DISC.

SW. AT 38" AFF

(3)SETS OF

4-500 KCMIL CABLES - 4"C

INCOMING SERVICE

FROM PSE&G GRID

SYSTEM. REFER TO SITE

PLAN DWG. E-312

1

1

23

456

7

23

6 5 4

7

3

E-225.00

CONDUIT SHALL BE PVC

CONDUIT EMBEDDED IN

3" CONCRETE ENVELOPE

52

53

56

57UP

8

8

NEW 4#500KCMIL + 1#1/OG IN 4"C

(CEILING SUPPORTED).

NEW 2 SETS OF 4#500KCMIL +

1#1/OG IN 4"C.

NEW #16AWG/4 TRIAD SHIELDED

CABLE IN 1

1

2

"C TO TOTALIZING

RELAY ENCLOSURE.

CONDUIT AND CABLE FROM

METER. CONTRACTOR TO

DETERMINE POWER SOURCE AND

LOAD CONNECTION TO METER AND

MAINTAIN SAME CONNECTION.

2

1

3

4

NEW 4 #2, 1 #8G IN 1

1

2

"C. SEE DWG.

E-622 FOR CIRCUIT CONNECTION

5

2

E-225.00

34

35

19

33

20

25

39

32

27

24

23

18

38

13

31

5

7 15

12

17

11

30

10

1

3

6

2

8

29 37

21 42

40

46

52

49 53

50 54

47 51 55

56

57

58

59

26

14

9

36

4

28

22

45

41

16

48

45

43

UP

UP UP

UP

UP

UP

F.F.E. 7.13'

F.F.E. 9.40'

F.F.E. 9.40'

34

35

19

33

20

25

39

32

27

24

23

18

38

13

31

5

7 15

12

17

11

30

10

1

3

6

2

8

29 37

21 42

40

46

52

49 53

50 54

47 51 55

56

57

58

59

26

14

9

36

4

28

22

45

41

16

48

45

43

UP

UP UP

UP

UP

UP

F.F.E. 7.13'

F.F.E. 9.40'

F.F.E. 9.40'

2

1 1

SEE PANEL SCHEDULE TO

CONNECT TO EXISTING LOAD.

SEE NOTES 4,5, 6,7&9

EXISTING 250A

PANELBOARD - HLP

M

EXISTING

LOCAL

METER 1

4

3

EXISTING

CONDUIT

AND WIRING

TO BE

REUSED

NEW POWER

PULL BOX

NEW

MDP A

NEW

MDP B

RELOCATED

METER T.R.E.

SEE NOTE 10

NEW PULL

BOX

SEE NOTE

8

PULLBOX

SEE E-111.00 NOTES 7&8

SEE NOTES 6&9

SEE NOTE 7

EXISTING LOAD

SEE NOTES 7&9

NEW AND/OR

EXISTING CONDUIT

AND WIRING SEE

NOTES 6, 7 & 9

NEW 600A 3 POLES

DISCONNECT

SWITCH TO BE

INSTALLED AT MIN.

36" AFF.

NEW 100A 3

PHASE LIGHTING

PANEL. LP11

NEW COMM.

PULL BOX

5

CP

B

1.5"

1

1

23

456

7

23

6 5 4

7

4

5

7

6

UNDER GROUND

CONCRETE PULL

BOX WITH STEEL

COVER. (TYP)

OPEN END

CONDUIT FOR

DRAIN (TYP)

8

8

1

E-225.00

KEY PLAN - BUILDING No. 11

SCALE: 1/16"=1'-0"

2

E-225.00

ELECTRICAL EQUIPMENT FIRST FLOOR PLAN - BUILDING No. 11

SCALE: 3/4"=1'-0"

N

N

NOTES:

1. FOR GENERAL NOTES, SYMBOLS AND

ABBREVIATIONS SEE DRAWING E-001.00.

2. INSTALL NEW EQUIPMENT 6" ABOVE SLR. FOR SLR

INFORMATION, SEE DRAWING E-611.00.

3. FOR CONSTRUCTION PHASING SEE DRAWING

E-004.00.

4. INSTALL NEW CONDUITS AND CABLE EXTENSIONS

FOR SUB FEEDER CABLES, FROM NEW PULLBOX TO

NEW MDPs. SEE E-611.00 FOR SCHEDULE OF MDPs.

5. EXISTING BRANCH FEEDERS SHALL BE EXTENDED

INTO THE PULL BOX AND SPLICED WITH NEW

EXTENDED CABLES FROM THE NEW MDP'S.

6. FOR EQUIPMENT IN THE ELECTRICAL ROOM

SERVED DIRECTLY FROM THE MDP, INSTALL NEW

CONDUITS AND WIRING FROM EQUIPMENT TO NEW

MDPs (WHERE EXISTING CONDUIT AND WIRING

ARE NOT ADEQUATE). ALLOW A MAXIMUM OF

100FEET OF CONDUIT AND WIRING PER EQUIPMENT

AFFECTED. OWNER SHALL BE CREDITED FOR

EXCESS CONDUIT AND WIRING NOT USED.

CONDUIT AND CABLE SHALL BE SIZED TO MATCH

EXISTING CONDITIONS.

7. FOR EQUIPMENT SERVED FROM OTHER LOCAL

PANEL BOARDS, AND AFFECTED BY RELOCATION,

INSTALL NEW BRANCH CIRCUIT CONDUIT AND

WIRING IF EXISTING CONDUIT AND WIRING ARE NOT

ADEQUATE. ALLOW A MAXIMUM OF100FEET OF

CONDUIT AND WIRING PER EQUIPMENT AFFECTED.

OWNER SHALL BE CREDITED FOR CONDUIT AND

WIRING NOT USED. CONDUIT AND CABLE SHALL BE

SIZED TO MATCH EXISTING CONDITIONS.

8. PULL BOX SHALL BE SIZED TO MATCH REQUIRED

CODE AND INSTALLED ABOVE 29.28" AFF. PULL BOX

SHALL BE USE FOR APARTMENT RISER.

9. CONTRACTOR SHALL BE RESPONSIBLE TO

DETERMINE THE CORRECT CONNECTION OF EVERY

EQUIPMENT IN THE ELECTRICAL ROOM, AND

ENSURE THAT FINAL CONNECTION MATCH

APPROPRIATELY.

10. NEW CABLE SHALL BE SPLICED TO EXISTING CABLE

IN THE ENCLOSURE, AND SHIELDED

APPROPRIATELY.

11. CONNECT ALL EQUIPMENT (NEW AND EXISTING) TO

EXISTING GROUND AS PER NEC STANDARDS.

12. 2"C FOR SCADA TERMINATES INSIDE CPB.

13. PROVIDE 2 # 10 + 1 #12G IN

3

4

" C FROM EACH

CIRCUIT TO CCTV SECURITY SYSTEM (SEE NOTE-2

& 3 SERIES SE-100.00 DRAWINGS) AS PER E-600

SERIES DRAWINGS AND ARE FOR LOCATION OF

CCTV SYSTEM OF SE-100 SERIES DRAWINGS.

14. PROVIDE GROUNDING BUS BAR AS PER NEC. FOR

COORDINATION, SEE DRAWINGS SE-100 SERIES

DRAWINGS FOR EXACT LOCATION.

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #11

3

E-225.00

FEEDER CONDUIT SHAFT LAYOUT DETAIL

SCALE: 1"=1'-0"

N

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

16658

KEY NOTES:

1

7

4

5

6

4x#500KCMIL IN 4"C FROM

PSE&G TRANSFORMER TO

ROOF ELECTRICAL ROOM.

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

4" CONDUIT SPARE

2" C FOR SCADA

1

1

2

" C FOR CAT 6 CABLES

1

1

2

" C FOR METER TOTALIZING

SYSTEM

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

2

3

1

1

2

" C FOR FIRE ALARM CONTROL

PANEL

SEE DWG. E-704 FOR MORE DETAILS

CONDUIT LEGEND:

8

3

4

" C FOR FIRE ALARM CONTROL

PANEL FROM 3P, 30A TRANSFER

SWITCH

4

E-225.00

ELECTRICAL ONE LINE DIAGRAM

N.T.S

03/08/2018

19

2735

20

2634

2533

1839

243032

1738 2331

13

14

15

9 5

610

711

16 12 8

1

2

3

421

36 28

22293743

41

40

42

45

45

46

4852

4953

5054

475155

56

57

58

59

UP

UP

UP

UP

UP

UP

OPEN TO CRAWLSPACE BELOW

ENTRANCE

EXISTLADDER

PUMP PIT

EXISTE.P.

EXISTWATER SERVICE

EXISTDOMESTIC

WATER PUMP

EXISTGAS

FIBEROPTIC

STORAGE

GAS RM

C.H.4 C.H.3 C.H.2

L.RK

CLCL B

C.H.1L.R K

KC.H.4C.H.3

C.H.2C.H.1

B CL CL CL

CLCLCL

C.H.2C.H.1 C.H.1

L.R

L.R B B

K

TANK & PUMP RM

METER RM

ENTRANCE HALLPUBLIC HALL

INC. RM

EXIT HALL

INC

ELEVATORS.S.C

F.F.E. 9.81'

F.F.E. 12.04'

F.F.E. 12.04'

INCOMING/

OUTGOING

2

E-226.00

52

53

56

57

A

EXISTING 30A

DISC. SW TO

PUMP 1 & 2

EXISTING 100A DISC.

SW OUTSIDE THE

BLDG.

WP

EXISTING EQUIPMENT

ON WALL

NEW 400A 3PHASE 4WIRE

MAIN DISTRIBUTION PANEL

B

SEE NOTE 4

1

NEW PULL BOX

EXIST. PNL BD TO

REMAIN, 250A

NEW LOCATION FOR

EXISTING METER T.R.E

3

NEW 400A 3PHASE 4WIRE

MAIN DISTRIBUTION PANEL

A

NEW LOCATION OF

EXISTING C/T METER

SEE

ELEVATION A

SEE NOTES 6,7 & 9

SEE NOTE

6, 7&9

SEE NOTE 9

SEE NOTE

6&7

NEW 600A 3 POLES

DISCONNECT SWITCH TO

BE INSTALLED AT >36"

AFF.

NEW 600A, 3 POLE

DISCONNECT SWITCH

2

NEW 100 A, 3 PHASE

LIGHTING PANEL LP 12

12

7 45

6

3

3

E-226.00

(6) SETS OF 4x#500 KCMIL

CABLES -4"C INCOMING

SERVICE FROM PSE&G GRID

SYSTEM. REFER TO SITE

PLAN DWG. E-312

4 21 3

5

6

7

NEW COMM PULLBOX

MTD AT CEILING SEE

NOTES 8&12NEW POWER PULL

BOX MTD AT CEILING

SEE NOTE 8

A

CONDUIT SHALL BE PVC

CONDUIT EMBEDDED IN 3"

CONCRETE ENVELOPE

8

8

NEW 4 #500 KCMIL + 1 #1/0G IN 4"C

(CEILING SUPPORTED).

NEW 2 SETS OF 4 #500 KCMIL + 1

#1/0G IN 4"C.

NEW #16AWG/4 TRIAD SHIELDED

CABLE IN1

1

2

"C TO TOTALIZING

RELAY ENCLOSURE.

CONDUIT AND CABLE FROM

METER. CONTRACTOR TO

DETERMINE SOURCE/LOAD

CONNECTION AND MAINTAIN SAME

CONNECTION.

2

1

3

4

NEW 4#2, 1#8G IN 1 1/2"C. SEE DWG.

E-622 FOR CIRCUIT CONNECTION

5

NEW POWER

PULLBOX

SEE NOTE 8

NEW COMM

PULLBOX

SEE NOTE 8& 12

42" A

FF

CEILING LEVEL

GRADE

LOUD. PUMP

DISC. SWITCH

TO REMAIN

VAC. PUMP

DISC. SWITCH

TO REMAIN

2

1

1

SEE PANEL SCHEDULE TO

CONNECT TO EXISTING LOAD.

SEE NOTES 4,5, 6,7&9

EXISTING 250A

PANELBOARD - HLP

M

EXISTING

LOCAL

METER 1

4

3

EXISTING CONDUIT

AND WIRING TO BE

REUSED

NEW

MDP A

NEW

MDP B

RELOCATED METER

T.R.E. SEE NOTE 10

NEW PULL BOX

SEE NOTE 8

PULLBOX

SEE E-112 NOTES 7&8

SEE NOTES 6&9

SEE NOTES 7

EXISTING LOAD

SEE NOTES 7&9

NEW AND/OR EXISTING

CONDUIT AND WIRING

SEE NOTES 6, 7 & 9

NEW 600A, 3 POLE

DISCONNECT

SWITCH TO BE

INSTALLED AT MIN.

36" AFF

NEW 100A 3

PHASE LIGHTING

PANEL. LP 12

2

NEW POWER

PULL BOX

NEW COMM.

PULL BOX

5

56

6

12

7 45

6

3

4 21 3

5

6

7

7

5

4

OPEN END

CONDUIT FOR

DRAIN (TYP)

UNDER GROUND

CONCRETE PULL BOX

WITH STEEL COVER.

(TYP)

8

8

1

E-226.00

KEY PLAN - BUILDING No. 12

SCALE: 1/32"=1'-0"

2

E-226.00

ELECTRICAL EQUIPMENT FIRST FLOOR PLAN - BUILDING No. 12

SCALE: 1/2"=1'-0"

N

N

NOTES:

1. FOR GENERAL NOTES, SYMBOLS AND

ABBREVIATIONS SEE DRAWING E-001.00.

2. INSTALL NEW EQUIPMENT 6" ABOVE SLR. FOR SLR

INFORMATION, SEE DRAWING E-612.00.

3. FOR CONSTRUCTION PHASING SEE DRAWING

E-004.00.

4. INSTALL NEW CONDUITS AND CABLE EXTENSIONS

FOR SUB FEEDER CABLES, FROM NEW PULLBOX

TO NEW MDPs. SEE E-612.00 FOR SCHEDULE OF

MDPs.

5. EXISTING BRANCH FEEDERS SHALL BE EXTENDED

INTO THE PULL BOX AND SPLICED WITH NEW

EXTENDED CABLES FROM THE NEW MDP'S.

6. FOR EQUIPMENT IN THE ELECTRICAL ROOM

SERVED DIRECTLY FROM THE MDP, INSTALL NEW

CONDUITS AND WIRING FROM EQUIPMENT TO

NEW MDPs (WHERE EXISTING CONDUIT AND

WIRING ARE NOT ADEQUATE). ALLOW A MAXIMUM

OF 100FEET OF CONDUIT AND WIRING PER

EQUIPMENT AFFECTED. OWNER SHALL BE

CREDITED FOR EXCESS CONDUIT AND WIRING

NOT USED. CONDUIT AND CABLE SHALL BE SIZED

TO MATCH EXISTING CONDITIONS.

7. FOR EQUIPMENT SERVED FROM OTHER LOCAL

PANEL BOARDS, AND AFFECTED BY RELOCATION,

INSTALL NEW BRANCH CIRCUIT CONDUIT AND

WIRING IF EXISTING CONDUIT AND WIRING ARE

NOT ADEQUATE. ALLOW A MAXIMUM OF100FEET

OF CONDUIT AND WIRING PER EQUIPMENT

AFFECTED. OWNER SHALL BE CREDITED FOR

CONDUIT AND WIRING NOT USED. CONDUIT AND

CABLE SHALL BE SIZED TO MATCH EXISTING

CONDITIONS.

8. PULL BOX SHALL BE SIZED TO MATCH REQUIRED

CODE AND INSTALLED AT CEILING AFF. PULL BOX

SHALL BE USE FOR APARTMENT RISER.

9. CONTRACTOR SHALL BE RESPONSIBLE TO

DETERMINE THE CORRECT CONNECTION OF

EVERY EQUIPMENT IN THE ELECTRICAL ROOM,

AND ENSURE THAT FINAL CONNECTION MATCH

APPROPRIATELY.

10. NEW CABLE SHALL BE SPLICED TO EXISTING

CABLE IN THE ENCLOSURE, AND SHIELDED

APPROPRIATELY.

11. CONNECT ALL EQUIPMENT (NEW AND EXISTING)

TO EXISTING GROUND AS PER NEC STANDARDS.

12. 2"C FOR SCADA TERMINATES INSIDE CPB.

13. PROVIDE 2 # 10 + 1 #12G IN

3

4

" C FROM EACH

CIRCUIT TO CCTV SECURITY SYSTEM (SEE NOTE-2

& 3 SERIES SE-100.00 DRAWINGS) AS PER E-600

SERIES DRAWINGS AND ARE FOR LOCATION OF

CCTV SYSTEM OF SE-100 SERIES DRAWINGS.

14. PROVIDE GROUNDING BUS BAR AS PER NEC. FOR

COORDINATION, SEE DRAWINGS SE-100 SERIES

DRAWINGS FOR EXACT LOCATION.

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #12

3

E-226.00

FEEDER CONDUIT SHAFT LAYOUT DETAIL

SCALE: 1"=1'-0"

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

16659

KEY NOTES:

1

7

4

5

6

4x#500KCMIL IN 4"C FROM

PSE&G TRANSFORMER TO

ROOF ELECTRICAL ROOM.

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

4" CONDUIT SPARE

2" C FOR SCADA

1

1

2

" C FOR CAT 6 CABLES

1

1

2

" C FOR METER TOTALIZING

SYSTEM

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

2

3

1

1

2

" C FOR FIRE ALARM CONTROL

PANEL

SEE DWG. E-704 FOR MORE DETAILS

CONDUIT LEGEND:

8

3

4

" C FOR FIRE ALARM CONTROL

PANEL FROM 3P, 30A TRANSFER

SWITCH

5

E-226.00

ELECTRICAL ONE LINE DIAGRAM

N.T.S

4

E-226.00

ELEVATION VIEW A

N.T.S

4'2'0

03/08/2018

2

E-227.00

F.F.E. 8.43'

F.F.E. 10.55'

F.F.E. 10.55'

19

27 35

20

26 34

25 33

18 39

24 30 32

17 3823 31

13

14

15

95

6 10

7 11

16128

1

2

3

4 21

3628

22 29 37 43

41

40

42

45

45

46

48 52

49 53

50 54

47 51 55

56

57

58

59

UP

UP

UP

UP& FLOOD PANEL

STORAGE ROOM

F.F.E. 8.43'

F.F.E. 10.55'

F.F.E. 10.55'

19

27 35

20

26 34

25 33

18 39

24 30 32

17 3823 31

13

14

15

95

6 10

7 11

16128

1

2

3

4 21

3628

22 29 37 43

41

40

42

45

45

46

48 52

49 53

50 54

47 51 55

56

57

58

59

UP

UP

UP

UP& FLOOD PANEL

STORAGE ROOM

52

53

56

57

CPB

NEW POWER PULL

BOX MTD AT

CEILING, SEE NOTE 8

EXISTING BOXES FOR TELCOM

EXISTING 60A

DISC. SWITCH

HCP

NEW PULL BOX AT MIN. 24"

AFF

EXISTING EQUIPMENT

AT MIN. 32" AFF.

SEE NOTE #4

NEW 400A 3P 4W

DIST. PANEL A

NEW 400A 3P 4W DIST.

PANEL B

EXISTING

METER T.R.E IN

NEW LOCATION

SEE

NOTE #4

3

NEW COMM PULL BOX

MTD AT CEILING SEE

NOTE 8 & 12

1

SEE NOTES

6, 7&9

SEE NOTE #9

NEW 600A, 3 POLE

DISCONNECT SWITCH

1

2

NEW 100 A, 3 PHASE

LIGHTING PANEL LP 13

EXISTING LOCAL

METER 1 AT NEW

HEIGHT MIN. 24" AFF

EXISTING PANEL

BOARD

127 45

6

3

(6) SETS OF 4x500 MCM - 4"C INCOMING

SERVICE FROM PSE&G GRID SYSTEM.

REFER TO SITE PLAN DWG. E-312

3

E-227.00

4 32 157

6

CONDUIT SHALL BE

PVC CONDUIT

EMBEDDED IN 3"

CONCRETE

ENVELOPE

52

53

56

57

8

8

NEW 4 #500 KCMIL + 1 #1/OG IN 4"C

(CEILING SUPPORTED).

NEW 2 SETS OF 4 #500 KCMIL + 1

#1/OG IN 4"C

#16AWG/4 TRIAD SHIELDED CABLE

IN 1

1

2

" CONDUIT TO TOTALIZING

RELAY ENCLOSURE

NEW CONDUIT AND CABLE FROM

METER. CONTRACTOR TO IDENTIFY

POWER SOURCE AND LOAD TO

METER, AND MAINTAIN SAME

CONNECTION.

2

1

3

4

NEW 4#2, 1#8G IN 1 1/2"C. SEE DWG.

E-623 FOR CIRCUIT CONNECTION

5

1 1

SEE PANEL SCHEDULE TO

CONNECT TO EXISTING LOAD.

SEE NOTES 4,5, 6,7&9

EXISTING 250A

PANELBOARD - HLP

M

EXISTING

LOCAL

METER 1

4

3

EXISTING CONDUIT

AND WIRING TO BE

REUSED

NEW

MDP A

NEW

MDP B

RELOCATED METER

T.R.E. SEE NOTE 10

NEW PULL BOX

SEE NOTE 8

PULLBOX

SEE E-113 NOTES 7&8

SEE NOTES 6&9

SEE NOTES 7

EXISTING LOAD

SEE NOTE 7&9

NEW AND/OR EXISTING

CONDUIT AND WIRING

SEE NOTES 6, 7 & 9

NEW 100A 3

PHASE LIGHTING

PANEL. LP13

2

NEW 600A, 3

POLE

DISCONNECT

SWITCH TO

BE INSTALLED

AT MIN. 36"

AFF

2

NEW POWER

PULL BOX

NEW COMM.

PULL BOX

5

56CPB

1.5

"

127 45

6

3

4 32 157

6

6

7

4

5

OPEN END

CONDUIT FOR

DRAIN (TYP)

UNDER GROUND

CONCRETE PULL BOX

WITH STEEL COVER.

(TYP)

56

8

8

1

E-227.00

KEY PLAN - BUILDING No. 13

SCALE: 1/16"=1'-0"

2

E-227.00

ELECTRICAL EQUIPMENT FIRST FLOOR PLAN - BUILDING No. 13

SCALE: 3/4"=1'-0"

N

N

NOTES:

1. FOR GENERAL NOTES, SYMBOLS AND

ABBREVIATIONS SEE DRAWING E-001.00.

2. INSTALL NEW EQUIPMENT 6" ABOVE SLR. FOR SLR

INFORMATION, SEE DRAWING E-613.00.

3. FOR CONSTRUCTION PHASING SEE DRAWING

E-004.00.

4. INSTALL NEW CONDUITS AND CABLE EXTENSIONS

FOR SUB FEEDER CABLES, FROM NEW PULLBOX TO

NEW MDPs. SEE E-613.00 FOR SCHEDULE OF MDPs.

5. EXISTING BRANCH FEEDERS SHALL BE EXTENDED

INTO THE PULL BOX AND SPLICED WITH NEW

EXTENDED CABLES FROM THE NEW MDP'S.

6. FOR EQUIPMENT IN THE ELECTRICAL ROOM SERVED

DIRECTLY FROM THE OLD MDP REMOVED MDP,

INSTALL NEW CONDUITS AND WIRING FROM

EQUIPMENT TO NEW MDP A & B (WHERE EXISTING

CONDUIT AND WIRING ARE NOT ADEQUATE). ALLOW

A MAXIMUM OF 100FEET OF CONDUIT AND WIRING

PER EQUIPMENT AFFECTED. OWNER SHALL BE

CREDITED FOR EXCESS CONDUIT AND WIRING NOT

USED. CONDUIT AND CABLE SHALL BE SIZED TO

MATCH EXISTING CONDITIONS.

7. FOR EQUIPMENT SERVED FROM OTHER LOCAL

PANEL BOARDS, AND AFFECTED BY RELOCATION,

INSTALL NEW BRANCH CIRCUIT CONDUIT AND

WIRING IF EXISTING CONDUIT AND WIRING ARE NOT

ADEQUATE. ALLOW A MAXIMUM OF100FEET OF

CONDUIT AND WIRING PER EQUIPMENT AFFECTED.

OWNER SHALL BE CREDITED FOR CONDUIT AND

WIRING NOT USED. CONDUIT AND CABLE SHALL BE

SIZED TO MATCH EXISTING CONDITIONS.

8. PULL BOX SHALL BE SIZED TO MATCH REQUIRED

CODE AND INSTALLED ABOVE AT CEILING AFF. PULL

BOX SHALL BE USE FOR APARTMENT RISER.

9. CONTRACTOR SHALL BE RESPONSIBLE TO

DETERMINE THE CORRECT CONNECTION OF EVERY

EQUIPMENT IN THE ELECTRICAL ROOM, AND

ENSURE THAT FINAL CONNECTION MATCH

APPROPRIATELY.

10. NEW CABLE SHALL BE SPLICED TO EXISTING CABLE

IN THE ENCLOSURE, AND SHIELDED

APPROPRIATELY.

11. CONNECT ALL EQUIPMENT (NEW AND EXISTING) TO

EXISTING GROUND AS PER NEC STANDARDS.

12. 2"C FOR SCADA TERMINATES INSIDE CPB.

13. PROVIDE 2 # 10 + 1 #12G IN

3

4

" C FROM EACH

CIRCUIT TO CCTV SECURITY SYSTEM (SEE NOTE-2 &

3 SERIES SE-100.00 DRAWINGS) AS PER E-600

SERIES DRAWINGS AND ARE FOR LOCATION OF

CCTV SYSTEM OF SE-100 SERIES DRAWINGS.

14. PROVIDE GROUNDING BUS BAR AS PER NEC. FOR

COORDINATION, SEE DRAWINGS SE-100 SERIES

DRAWINGS FOR EXACT LOCATION.

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #13

3

E-227.00

FEEDER CONDUIT SHAFT LAYOUT DETAIL

SCALE: 1"=1'-0"

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

16660

KEY NOTES:

1

7

4

5

6

4x#500KCMIL IN 4"C FROM

PSE&G TRANSFORMER TO

ROOF ELECTRICAL ROOM.

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

4" CONDUIT SPARE

2" C FOR SCADA

1

1

2

" C FOR CAT 6 CABLES

1

1

2

" C FOR METER TOTALIZING

SYSTEM

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

2

3

1

1

2

" C FOR FIRE ALARM CONTROL

PANEL

SEE DWG. E-704 FOR MORE DETAILS

CONDUIT LEGEND:

8

3

4

" C FOR FIRE ALARM CONTROL

PANEL FROM 3P, 30A TRANSFER

SWITCH

4

E-227.00

ELECTRICAL ONE LINE DIAGRAM

N.T.S

03/08/2018

2

E-228.00

2634

2533

19

2735

20

1839

243032

1738 2331

13

14

15

9 5

610

711

16 12 8

1

2

3

421

36 28

22293743

41

40

42

45

45

46

4852

4953

5054

475155

56

57

58

59

UP

UP

UP

UP

UP

UP

FLOOD PANEL STORAGE

HALL

I

O

OI

I O

7

8

3

4

UP

NEW LOCATION

FOR PANEL BOARD

AT >44" AFF,

NEW PULL BOX

AT MIN. 44" AFF

PB

CP

B

EXISTING

EQUIPMENT

AT >44" AFF

EXISTING DISC.

SW. AT 45" AFF

1

1

3

NEW 100A 3 PHASE

LIGHTING PANEL. LP14

1

2

1

NEW 400A 3PHASE 4WIRE

MAIN DISTRIBUTION

PANEL D

NEW POWER PULL BOX

SEE NOTE #8

NEW 400A 3PHASE 4WIRE

MAIN DISTRIBUTION

PANEL C

EXISTING 30A AT 69" AFF

NEW 600A, 3 POLE

DISCONNECT SWITCH

SEE NOTES 6&7

NEW COMM

PULL BOX. SEE

NOTES 8 & 12

EXISTING DISC.

SW. AT 36" AFF RE.

OCATED TO >40" AFF

NEW 400A

3PHASE

4WIRE MDP A.

ELEVATION

VIEW A

NEW LOCATION OF

EXISTING PANEL BOARD

AT 23"

NEW LOCATION OF

EXISTING METER T.R.E

RELOCATED AT ABOVE

DISC. SW.BELOW.

EXISTING 30A

DISC. SW ATAT

>44" AFF

NEW 400A

3PHASE 4WIRE

MDP B.

EXISTING LTG.

CONTROL AT

48.5" AFF

NEW LOCATION

FOR EXISTING

LOCAL METER 1

AT MIN. 4" AFF

SEE NOTES 4

SEE NOTES 4

SEE NOTES 6 & 7

SEE NOTES 6, 7 & 9

(3) SETS OF 4-500

KCMIL CABLES -4"C

INCOMING SERVICE

FROM PSE&G GRID

SYSTEM. REFER TO

SITE PLAN DWG.

E-312

1

1

23

456

7

23

6 5 4

7

3

E-228.00

A A

CONDUIT SHALL BE PVC

CONDUIT EMBEDDED IN 3"

CONCRETE ENVELOPE

8

8

SLR 12.5"

3'-1

3

16

"

6"

CEILING

HEIGHT CP

B

NEW COMM

PULL BOX. SEE

NOTE 8 & 12

NEW POWER

PULL BOX.

SEE NOTE 8

NEW LOCATION

OF DISC. SW

NEW LOCATION

OF METER T.R.E

NEW

400A

3P 4W

MDPA

NEW LOCATION

OF DISC. SW

1 1

SEE PANEL SCHEDULE TO

CONNECT TO EXISTING LOAD.

SEE NOTES 4,5, 6,7&9

NEW 250A

PANELBOARD - HLP

M

EXISTING LOCAL

METER 1

4

3

EXISTING CONDUIT

AND WIRING TO BE

REUSED

NEW

MDP C

NEW

MDP A

RELOCATED METER

T.R.E. SEE NOTE 10

NEW PULL BOX

SEE NOTE 8

PULLBOX

SEE E-114 NOTES 7&8

SEE NOTES 6&9

SEE NOTES 7

EXISTING LOAD

SEE NOTE 7&9

NEW AND/OR EXISTING

CONDUIT AND WIRING

SEE NOTE 6, 7 & 9

NEW

MDP B

NEW

MDP D

NEW 100A 3

PHASE LIGHTING

PANEL. LP14

1

1

2

NEW 600A, 3 POLE

DISCONNECT SWITCH TO BE

INSTALLED AT MIN. 36" AFF

2

NEW POWER

PULL BOX

NEW COMM.

PULL BOX

5

NEW 4 #500 KCMIL + 1 #1/OG IN 4"C

(CEILING SUPPORTED).

NEW 2 SETS OF 4 #500 KCMIL + 1

#1/OG IN 4"C.

#16AWG/4 TRIAD SHIELDED CABLE

IN 1

1

2

" CONDUIT TO TOTALIZING

RELAY ENCLOSURE

NEW CONDUIT AND CABLE FROM

METER. CONTRACTOR TO

RECONNECT METER

2

1

3

4

NEW 4#2, 1#8G IN 1 1/2"C. SEE DWG.

E-623 FOR CIRCUIT CONNECTION

5

4

CP

B

1.5"

1

1

23

456

7

23

6 5 4

7

4

5

7

6

OPEN END

CONDUIT FOR

DRAIN (TYP)

UNDER GROUND

CONCRETE PULL BOX

WITH STEEL COVER.

(TYP)

8

8

1

E-228.00

KEY PLAN - BUILDING No. 14

SCALE: 1/16"=1'-0"

2

E-228.00

ELECTRICAL METER ROOM - BUILDING No. 14

SCALE: 3/4"=1'-0"

N

N

NOTES:

1. FOR GENERAL NOTES, SYMBOLS AND

ABBREVIATIONS SEE DRAWING E-001.00.

2. INSTALL NEW EQUIPMENT 6" ABOVE SLR. FOR SLR

INFORMATION, SEE DRAWING E- 614.00.

3. FOR CONSTRUCTION PHASING SEE DRAWING

E-001.00.

4. INSTALL NEW CONDUITS AND CABLE EXTENSIONS

FOR SUB FEEDER CABLES, FROM NEW PULLBOX

TO NEW MDPs. SEE E-614.00 FOR SCHEDULE OF

MDP's.

5. EXISTING BRANCH FEEDERS SHALL BE EXTENDED

INTO THE PULL BOX AND SPLICED WITH NEW

EXTENDED CABLES FROM THE NEW MDP'S.

6. FOR EQUIPMENT IN THE ELECTRICAL ROOM

SERVED DIRECTLY FROM THE MDP, INSTALL NEW

CONDUITS AND WIRING FROM EQUIPMENT TO

NEW MDPs (WHERE EXISTING CONDUIT AND

WIRING ARE NOT ADEQUATE). ALLOW A MAXIMUM

OF 100FEET OF CONDUIT AND WIRING PER

EQUIPMENT AFFECTED. OWNER SHALL BE

CREDITED FOR EXCESS CONDUIT AND WIRING

NOT USED. CONDUIT AND CABLE SHALL BE SIZED

TO MATCH EXISTING CONDITIONS.

7. FOR EQUIPMENT SERVED FROM OTHER LOCAL

PANEL BOARDS, AND AFFECTED BY RELOCATION,

INSTALL NEW BRANCH CIRCUIT CONDUIT AND

WIRING IF EXISTING CONDUIT AND WIRING ARE

NOT ADEQUATE. ALLOW A MAXIMUM OF100FEET

OF CONDUIT AND WIRING PER EQUIPMENT

AFFECTED. OWNER SHALL BE CREDITED FOR

CONDUIT AND WIRING NOT USED. CONDUIT AND

CABLE SHALL BE SIZED TO MATCH EXISTING

CONDITIONS.

8. PULL BOX SHALL BE SIZED TO MATCH REQUIRED

CODE AND INSTALLED AT CEILING AFF. PULL BOX

SHALL BE USE FOR APARTMENT RISER.

9. CONTRACTOR SHALL BE RESPONSIBLE TO

DETERMINE THE CORRECT CONNECTION OF

EVERY EQUIPMENT IN THE ELECTRICAL ROOM,

AND ENSURE THAT FINAL CONNECTION MATCH

APPROPRIATELY.

10. NEW CABLE SHALL BE SPLICED TO EXISTING

CABLE IN THE ENCLOSURE, AND SHIELDED

APPROPRIATELY.

11. CONNECT ALL EQUIPMENT (NEW AND EXISTING)

TO EXISTING GROUND AS PER NEC STANDARDS.

12. 2"C FOR SCADA TERMINATES INSIDE CPB.

13. PROVIDE 2 # 10 + 1 #12G IN

3

4

" C FROM EACH

CIRCUIT TO CCTV SECURITY SYSTEM (SEE NOTE-2

& 3 SERIES SE-100.00 DRAWINGS) AS PER E-600

SERIES DRAWINGS AND ARE FOR LOCATION OF

CCTV SYSTEM OF SE-100 SERIES DRAWINGS.

14. PROVIDE GROUNDING BUS BAR AS PER NEC. FOR

COORDINATION, SEE DRAWINGS SE-100 SERIES

DRAWINGS FOR EXACT LOCATION.

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #14

3

E-228.00

FEEDER CONDUIT SHAFT LAYOUT DETAIL

SCALE: 1"=1'-0"

N

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 8

2N

D S

T.

BE

AC

H 83

TH

S

T.

BE

AC

H 84

TH

S

T.

BE

AC

H 85

TH

S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 8

3T

H S

T.

BE

AC

H 8

2N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86

TH

S

T.

BE

AC

H 81

ST

S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

16661

KEY NOTES:

1

7

4

5

6

4x#500KCMIL IN 4"C FROM

PSE&G TRANSFORMER TO

ROOF ELECTRICAL ROOM.

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

4" CONDUIT SPARE

2" C FOR SCADA

1

1

2

" C FOR CAT 6 CABLES

1

1

2

" C FOR METER TOTALIZING

SYSTEM

4x#500KCMIL,1# 1/0G AWG IN 4"C

FROM ROOF ELECTRICAL ROOM

TO FIRST FLOOR ELECT. ROOM

2

3

1

1

2

" C FOR FIRE ALARM CONTROL

PANEL

SEE DWG. E-704 FOR MORE DETAILS

CONDUIT LEGEND:

8

3

4

" C FOR FIRE ALARM CONTROL

PANEL FROM 3P, 30A TRANSFER

SWITCH

4

E-228.00

ELEVATION VIEW A

N.T.S

5

E-228.00

ELECTRICAL ONE LINE DIAGRAM

N.T.S

03/08/2018

ROCKAWAY BEACH BOULEVARD

2

4

3

1

BE

AC

H 86T

H S

T.

OU

TG

OIN

G

IN

CO

MIN

G

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

INCOMING

FOR CONTINUATION SEE DWG. E-302.00

FO

R C

ON

TIN

UA

TIO

N S

EE

D

WG

. E

-3

03

.0

0

1. FOR LIGHTING POLE & POLE TOP FIXTURE DETAILS SEE

DRAWINGS E-320.00, E-321.00 & E-322.00.

2. FOR WALL PACK AND ENTRANCE LIGHT FIXTURE

(ATTACHED TO THE BUILDING) DETAILS SEE DRAWING

E-303.00, TABLE A.

3. FOR PANEL SCHEDULES SEE DRAWINGS E-620.00

THROUGH E-623.00.

4. ALL UNDERGROUND CONDUITS SHALL BE PVC COATED

GALVANIZED RIGID METALLIC CONDUIT TYPE AND WIRE

SHALL BE XHHW

5. COORDINATE TRENCH WORK WITH CIVIL AND OTHER

TRADES.

6. ALL SITE LIGHTING AND LIGHTING ATTACHED TO THE

BUILDING FOR EACH BUILDING SHALL BE CONTROLLED

BY A TIME CLOCK. SEE DRAWING E-303.00 FOR

DETAILS.

7. KEEP THE EXISTING SITE LIGHTING IN SERVICE UNTIL

THE NEW LIGHTING POLES & LIGHTING ARE INSTALLED

TESTED AND COMMISSIONED. REMOVE EXISTING SITE

LIGHTING AND ASSOCIATE CONDUIT & CABLES AFTER

NEW LIGHTING SYSTEM IS IN OPERATION.

8. FOR PANEL LOCATIONS SEE E-215.00 THROUGH

E-228.00.

9. FOR PHASING NOTES SEE DRAWING E-115.00.

10. ALL UNDERGROUND CONDUITS SHALL BE INSTALLED

AS PER NEC 300.5

FINISHED GRADE

IMC OR RIGID METALLIC RISER

24" MIN.

PVC COATED

GALVANIZED RIGID

METALLIC CONDUIT

COUPLER BELOW FINISHED GRADE

12" MIN.

BUILDING #1, 2, 3 AND 4

TRENCH

CONDUIT

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

PROVIDE ASPHALTIC COATING OF

RISER BELOW GRADE TO 6" ABOVE

GRADE

1

E-301.00

SITE LIGHTING FOR BUILDING 1, 2, 3 AND 4

SCALE: 1"=25'

N

2

E-301.00

DETAIL 1: TYPICAL UNDERGROUND CONDUIT INSTALLATION DETAILS

SCALE: NOT TO SCALE

NOTES:

CONDUIT ABOVE GROUND ON WALL / CEILING

CONDUIT UNDERGROUND

LEGEND:

62 166

-

AS SHOWN

AMIT GULERIA

MARJORY MITCHELL

0 50'25'

03/08/2018

5

6

BE

AC

H 84T

H S

T.

HAMMEL BOULEVARD

OU

TG

OIN

G

INCOMING

OUTGOING

IN

CO

MIN

G

5

6

BE

AC

H 84T

H S

T.

HAMMEL BOULEVARD

OU

TG

OIN

G

INCOMING

OUTGOING

IN

CO

MIN

G

FO

R C

ON

TIN

UA

TIO

N S

EE

D

WG

. E

-3

04

FOR CONTINUATION SEE DWG. E-301

BUILDING #5 AND 6

1. FOR NOTES SEE DRAWING E-301.00.

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

1

E-302.00

SITE LIGHTING FOR BUILDING 5 & 6

SCALE: 1"=25'

N

NOTES:

CONDUIT ABOVE GROUND ON WALL / CEILING

CONDUIT UNDERGROUND

LEGEND:

63 166

-

AS SHOWN

AMIT GULERIA

MARJORY MITCHELL

0 50'25'

03/08/2018

** TIMECLOCK SHALL USE 2#8,1#10G-3/4"C.

TIME

CLOCK

LP1

SITE POLE

LIGHTING

LIGHTING

ATTACHED

TO BUILDING

10

9

7

8

OU

TG

OIN

GIN

CO

MIN

G

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

INCOMING

BE

AC

H 81S

T S

TR

EE

T

FOR CONTINUATION SEE DWG. E-304

FO

R C

ON

TIN

UA

TIO

N S

EE

D

WG

. E

-3

01

BUILDING #7, 8, 9 AND 10

1. FOR NOTES SEE DRAWING E-301.00.

1. NEW TIME CLOCK

SHALL BE INSTALLED

FOR EACH BUILDING.

(NOTE: THIS APPLIES TO EACH BUILDING)

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

LITHONIA

LIGHTING

VGR1C

2/26TRT

(WALL MOUNT)

GATEWAY DEEP CAST ROUND CF

FIXTURE WITH POLYCARBO NATE

LENS

TWO 15W LUNERA HELEN LED

RETROFIT LAMPS, TILTED 15-DEG UP

FROM VERTICAL BASE-UP POSITION

VGEIC_2_26

TRT_HELEN LAMP

(WALL_MOUNT) .ies

0.85 3424

MANUFACTURER

CATALOG

NUMBER

DESCRIPTION LAMP FILENAME WATTAGEQUANTITY

EB-1

LABELSYMBOL

LITHONIA

LIGHTING

VGR1C

2/26TRT

(CEILING MOUNT)

GATEWAY DEEP CAST ROUND CF

FIXTURE WITH POLYCARBO NATE

LENS

TWO 15W LUNERA HELEN LED

RETROFIT LAMPS, TILTED 15-DEG UP

FROM VERTICAL BASE-UP POSITION

VGEIC_2_26

TRT_HELEN LAMP

(CEILING_MOUNT) .ies

52EA-1

LITHONIA

LIGHTING

DSXW1 LED

20C 1000 40K

T3M MVOLT

DSXW1 LED WITH 2 LIGHT ENGINES,

20 LED'S, 1000MA DRIVER, 4000K

LED, TYPE 3 MEDIUM OPTIC

LED 4000K

DSXW1_LED_

20C_1000_40K_

T3M_M VOLT.ies

60W-2

LITHONIA

LIGHTING

DSXW1 LED

30C 1000

40K T3M MVOLT

DSXW2 LED WITH 3 LIGHT ENGINES,

30 LED'S, 1000MA DRIVER, 4000K

LED, TYPE 3 MEDIUM OPTIC

DSXW2_LED_

30C_1000_40K_

T3M_M VOLT.ies

2W-2A

LIGHT LOSS

FACTOR

LED 4000K

0.85

0.85

0.85

34

75

109

AMERICAN

ELECTRIC

LIGHTING

ACP1LED 6

10A XXX 66

4K

ACP1 LED WITH 6 COB'S, 4000K

COLOR TEMPERATURE, 1050mA

DRIVE CURRENT, 6X6 DISTRIBUTION

ACP1LED_6_

10A_XXX_66

_4K.ies

25FA-2

LED

0.85 480

HOLOPHANE

PUL1054KAS

XL5X

UTILITY POST TOP FCO LED, TYPE 5

OPTICS

PUL1055KAS

XL5X.ies

111P-3

LED 4000K

0.85 99

ATBM C

MVOLT R3

4B XX P5

ATBM C PERFORMANCE PACKAGE,

4000K COLOR TEMPERATURE,

ROADWAY TYPE III DISTRIBUTION

ATBM_C_XX

XXX_R3_XXX

X.ies

24SA-3

LED COB

0.85 81

AMERICAN

ELECTRIC

LIGHTING

ATBM C

MVOLT R3

4B XX P5

ATBM C PERFORMANCE PACKAGE,

4000K COLOR TEMPERATURE,

ROADWAY TYPE III DISTRIBUTION

ATBM_C_XX

XXX_R3_XXX

X.ies

4SB-3

LED COB

0.85 162

AMERICAN

ELECTRIC

LIGHTING

1

E-303.00

SITE LIGHTING FOR BUILDING 7, 8, 9 & 10

SCALE: 1"=25'

N

NOTES:

CONDUIT ABOVE GROUND ON WALL / CEILING

CONDUIT UNDERGROUND

LEGEND:

2

E-303.00

TYPICAL SITE LIGHTING & LIGHTING

ATTACHED TO THE BUILDING CONTROL DETAILS

SCALE: NOT TO SCALE

3

E-303.00

TABLE A - LIGHT FIXTURES

SCALE: NOT TO SCALE

NOTES:

64 166

-

AS SHOWN

AMIT GULERIA

MARJORY MITCHELL

0 50'25'

03/08/2018

12

11

13

14

OU

TG

OIN

G

IN

CO

MIN

G

OU

TG

OIN

G

IN

CO

MIN

G

OU

TG

OIN

G

INCOMING

EX

IS

T. M

ET

ER

RO

OM

LO

CA

TE

D

AT

1S

T F

LO

OR

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

IN

CO

MIN

G

HAMMEL BOULEVARD

FO

R C

ON

TIN

UA

TIO

N S

EE

D

WG

. E

-3

02

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

BUILDING #11, 12, 13 & 14

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

FOR CONTINUATION SEE DWG. E-303

1. FOR NOTES SEE DRAWING E-301.00.

1

E-304.00

SITE LIGHTING FOR BUILDING 11, 12, 13 & 14

SCALE: 1"=25'

N

NOTES:

CONDUIT ABOVE GROUND ON WALL / CEILING

CONDUIT UNDERGROUND

LEGEND:

65 166

-

AS SHOWN

AMIT GULERIA

MARJORY MITCHELL

0 50'25'

03/08/2018

2

4

3

1

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

INCOMING

2

4

3

1

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

INCOMING

(4) NEW SETS OF 4-500 MCM,

CABLES IN 4-4" CONDUIT

ROCKWAY BEACH BOULEVARD

BE

AC

H 86T

H S

TR

EE

T

(5) SETS OF 4х500 MCM

CABLES IN 5-4" CONDUIT

INSTALLED 18" BELOW GRADE

(5) SETS OF

4-500 MCM

CABLES IN

5-4"

CONDUIT

(3) SETS OF 4х500 MCM ,

CABLES IN 3-4" CONDUIT

225KVA

FOR CONTINUATION

SEE DWG. E-404

SEE DWG. E-218 FOR

ELECTRICAL BLDG NO.

4 FOR CABLE ENTRY

DETAIL

SEE DWG E-401

FOR CONTINUATION

SEE DWG E-215 FOR

ELECTRICAL BLDG NO. 1

FOR CABLE ENTRY DETAIL

FOR CONTINUATION SEE E-403

SEE DWG. E-217 FOR

ELECTRICAL BLDG

NO. 3 FOR CABLE ENTRY

DETAIL

SEE DWG. E-402 FOR

CONTINUATION

SEE DWG. E-216 FOR

ELECTRICAL BLDG

NO. 2 FOR CABLE

ENTRY DETAIL

225KVA

150KVA

TR

TR

TR

1. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION

OF EXISTING PSE&G TRANSFORMERS AND CRAB

CONNECTION/VAULTS. ALL CRAB CONNECTIONS SHALL

BE REPLACED TO ACCOMMODATE NEW REPLACED

CABLES.

2. PRIOR TO THE INSTALLATION THE CONTRACTOR SHALL

SUBMIT SHOP DRAWINGS SHOWING THE LAYOUT OF

UNDERGROUND CONDUITS FROM EXISTING

TRANSFORMER TO EACH BUILDING. THE CONTRACTOR

SHALL PROCEED WITH THE INSTALLATION ONLY AFTER

THE APPROVAL OF THE SHOP DRAWINGS.

3. THE CONTRACTOR SHALL COORDINATE WITH PSE&G

THE INSTALLATION OF CABLES TO THE TRANSFORMERS.

4. REFER TO CIVIL DRAWINGS FOR TRENCHING AND

EXCAVATION INFORMATION.

5. THE CONTRACTOR SHALL CO-ORDINATE WITH CIVIL

WORK DURING UNDERGROUND CONDUIT INSTALLATION.

ALL EXCAVATION /DIGING WORK SHALL BE PERFORMED

BY HAND.

6. THE CONTRACTOR TO CO-ORDINATE WITH ALL EXISTING

MEP EQUIPMENTS, PIPES ETC., AND SHALL PROTECT

THEM FROM DAMAGE IF EXPOSED DURING ELECTRICAL

INSTALLATION.

7. CONTRACTOR TO MAKE SURE NEC 300.5 SATISFIED FOR

UNDERGROUND CABLE RUN.

8. FOR BUILDING PLANS SEE DRAWINGS E-215.00

THROUGH E-228.00.

9. FOR RISER DIAGRAMS SEE DRAWING E-401.00 THROUGH

E-414.00.

10. FOR DEMOLITION OF EXISTING SERVICE SEE DWG

E-401.00 THROUGH E-414.00. ALSO, IT IS INDICATED ON

TASK 5 AND TASK 2 ON DWG E-004.00 AND DWG E-005.00

RESPECTIVELY.

BUILDING NUMBER.

FOR CONTINUATION SEE DWG. E-310

FO

R C

ON

TIN

UA

TIO

N S

EE

D

WG

. E

-3

11

CABLE PULL BOX

EXISTING PSEG ELECTRICAL MANHOLE

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

1

E-309.00

ELECTRICAL SITE UTILITY PLAN BUILDINGS 1, 2, 3 & 4

SCALE: 1"=25'

N

NOTES:

LEGEND:

BUILDING #1, 2, 3 AND 4

NEW SERVICE FROM EXISTING PSEG

TRANSFORMER TO THE BUILDING EXTERIOR

OF ELECTRICAL ROOM LOCATED IN FIRST

FLOOR.

EXISTING PAD MOUNTED OUTDOOR TYPE

TRANSFORMER. PSE&G 13.2KV/208V.

TR

X

E

66 166

-

AS SHOWN

AMIT GULERIA

MARJORY MITCHELL

0 50'25'

03/08/2018

5

6

OU

TG

OIN

G

INCOMING

OUTGOING

IN

CO

MIN

G

5

6

OU

TG

OIN

G

INCOMING

OUTGOING

IN

CO

MIN

G

(3) SETS OF

4х500 MCM,

CABLES IN

3-4"

CONDUIT

BE

AC

H 84T

H S

TR

EE

T

(4) SETS OF 4х500 MCM ,

CABLES IN 4-4" CONDUIT

SEE DWG. E-405 FOR

CONTINUATION

SEE DWG. E-219 FOR

ELECTRICAL

BLDG NO. 5 FOR CABLE

ENTRY DETAIL

SEE DWG E-406

FOR CONTINUATION

SEE DWG. E-220 FOR

ELECTRICAL BLDG NO. 6

FOR CABLE ENTRY

DETAIL

300 KVA

(6) SETS OF 4х500 KCMIL

IN 4" C

TR

1. FOR LEGEND AND NOTES SEE DRAWING E-309.00.

FOR CONTINUATION SEE DWG. E-309

FO

R C

ON

TIN

UA

TIO

N S

EE

D

WG

. E

-3

12

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

BUILDING NUMBER.

CABLE PULL BOX

EXISTING PSEG ELECTRICAL MANHOLE

1

E-310.00

ELECTRICAL SITE UTILITY PLAN BUILDINGS 5 & 6

SCALE: 1"=25'

N

NOTES:

LEGEND:

NEW SERVICE FROM EXISTING PSEG

TRANSFORMER TO THE BUILDING EXTERIOR

OF ELECTRICAL ROOM LOCATED IN FIRST

FLOOR.

EXISTING PAD MOUNTED OUTDOOR TYPE

TRANSFORMER. PSE&G 13.2KV/208V.

TR

X

E

BUILDING #5 AND 6

67 166

-

AS SHOWN

AMIT GULERIA

MARJORY MITCHELL

0 50'25'

03/08/2018

10

9

7

8

OU

TG

OIN

G

INCOMING

EX

IS

T. M

ET

ER

RO

OM

LO

CA

TE

D

AT

1S

T F

LO

OR

OU

TG

OIN

GIN

CO

MIN

G

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

INCOMING

BE

AC

H 81S

T S

TR

EE

T

(3) SETS OF 4х500 MCM,

CABLES IN 3-4" CONDUIT

(3) SETS OF 4х500

MCM, CABLES IN

3-4" CONDUIT

ROCKAWAY BEACH BOULEVARD

(4) SETS OF 500 MCM,

CABLES IN 4-4" CONDUIT

SEE E-409 FOR

CONTINUATION

SEE DWG. E-223

FOR ELECTRICAL

BLDG

NO. 9 FOR CABLE

ENTRY DETAIL

112KVA

500KVA

FOR CONTINUATION

SEE DWG. E-408.

FOR BUILDING NO. 8

CABLE ENTRY DETAIL

SEE DWG. E-222.

(5) SETS OF

4х500 MCM ,

CABLES IN

5-4" CONDUIT

SEE DWG E-407 FOR

CONTINUATION

SEE DWG. E-221 FOR

ELECTRICAL BLDG

NO. 7 FOR CABLE

ENTRY DETAIL

300 KVA

10

9

7

8

OU

TG

OIN

G

INCOMING

EX

IS

T. M

ET

ER

RO

OM

LO

CA

TE

D

AT

1S

T F

LO

OR

OU

TG

OIN

GIN

CO

MIN

G

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

INCOMING

TR

TR

TR

E

FO

R C

ON

TIN

UA

TIO

N S

EE

D

WG

. E

-3

09

FOR CONTINUATION SEE DWG. E-312

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

1. FOR LEGEND AND NOTES SEE DRAWING E-309.00.

BUILDING NUMBER.

CABLE PULL BOX

EXISTING PSEG ELECTRICAL MANHOLE

1

E-311.00

ELECTRICAL SITE UTILITY PLAN BUILDINGS 7, 8 & 9

SCALE: 1"=25'

N

NOTES:

LEGEND:

NEW SERVICE FROM EXISTING PSEG

TRANSFORMER TO THE BUILDING EXTERIOR

OF ELECTRICAL ROOM LOCATED IN FIRST

FLOOR.

EXISTING PAD MOUNTED OUTDOOR TYPE

TRANSFORMER. PSE&G 13.2KV/208V.

TR

X

E

68 166

-

AS SHOWN

AMIT GULERIA

MARJORY MITCHELL

BUILDING #7, 8, AND 9

0 50'25'

03/08/2018

12

11

13

14

OU

TG

OIN

G

IN

CO

MIN

G

OU

TG

OIN

G

IN

CO

MIN

G

OU

TG

OIN

G

INCOMING

EX

IS

T. M

ET

ER

RO

OM

LO

CA

TE

D

AT

1S

T F

LO

OR

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

IN

CO

MIN

G

(6) SETS OF 4х500 MCM,

CABLES IN 6-4" CONDUIT

H

A

M

M

E

L

B

O

U

L

E

V

A

R

D

(6) SETS OF 4х500 MCM ,

CABLES IN 6-4" CONDUIT

(3) SETS OF 4х500 MCM,

CABLES IN 3-4" CONDUIT

(3) SETS OF 4-500 MCM,

CABLES IN 3-4" CONDUIT

NEW UTILITY

APPROVED

HANDHOLE

UTILITY

APPROVED

HANDHOLE

SEE DWG E-414 FOR CONTINUATION

SEE DWG. E-228 FOR ELECTRICAL BLDG

NO. 14 FOR CABLE ENTRY DETAIL

225KVA

112KVA

300KVA

SEE DWG E-413 FOR CONTINUATION

SEE DWG. E-227 FOR ELECTRICAL BLDG

NO. 13 FOR CABLE ENTRY DETAIL

SEE E-411 FOR CONTINUATION

SEE DWG. E-225 FOR ELECTRICAL BLDG

NO. 11 FOR CABLE ENTRY DETAIL

SEE E-412

FOR CONTINUATION

SEE E-410 FOR CONTINUATION

SEE DWG. E-224 FOR ELECTRICAL

BLDG NO. 10 FOR CABLE ENTRY

DETAIL

(3) SETS OF 4х500 MCM,

CABLES IN 3-4" CONDUIT

12

11

13

14

OU

TG

OIN

G

IN

CO

MIN

G

OU

TG

OIN

G

IN

CO

MIN

G

OU

TG

OIN

G

INCOMING

EX

IS

T. M

ET

ER

RO

OM

LO

CA

TE

D

AT

1S

T F

LO

OR

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

IN

CO

MIN

G

12

11

13

14

OU

TG

OIN

G

IN

CO

MIN

G

OU

TG

OIN

G

IN

CO

MIN

G

OU

TG

OIN

G

INCOMING

EX

IS

T. M

ET

ER

RO

OM

LO

CA

TE

D

AT

1S

T F

LO

OR

OU

TG

OIN

G

INCOMING

OU

TG

OIN

G

IN

CO

MIN

G

NOTE:

1. FOR LEGEND AND NOTES SEE DRAWING E-309.00.

NEW SERVICE FROM EXISTING PSEG

TRANSFORMER TO THE BUILDING

EXTERIOR OF ELECTRICAL ROOM

LOCATED IN FIRST FLOOR.

LEGEND:

EXISTING PAD MOUNTED OUTDOOR

TYPE TRANSFORMER. PSEG

13.2KV/208V.

BUILDING NUMBER.

CABLE PULL BOX

EXISTING PSEG ELECTRICAL

MANHOLE

1

E-312.00

ELECTRICAL SITE UTILITY PLAN

SCALE: 1"=25'

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #10, 11, 12, 13 & 14

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

16669

0 50'25'

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP-1

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

UNIT HEATER

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

STAIR CASE LIGHT

SPARE

SPARE

LOAD (W)

LOAD (W)

1

1

1

1

2

2

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 1

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

100

DEVICE

PROTECTIVE

AC

PUMP

ELEVATOR

COMPACT

BUILDING 1

3HOUSE PANEL

3029

1003

1003

203

603

OFFICE

SPARE

903

3

303

903

803

803

1ST FL

3

2ND-7TH FL

603

125

150

APT A+B

APT A+B+C

2ND-7TH

APT C

2ND-7TH FL

APT G+H

2ND-7TH FL

APT D

2ND-7TH

APT E

2ND-7TH

APT F

OFFICE

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 1

SPARE

LP-1

SPARE SPARE

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

1

2

3

2 SETS OF 500 KCMIL + 1#1/0(G) IN (2)-4"C

2 SETS 4-350 KCMIL 1#1/0(G) IN (2)-3"C

4 SETS 4-500 KCMIL + 1#1/0(G) IN (3)-4"C

3 100

184

184

1

1

1

20

20

20

SPARE

SPARE

KEY NOTES:

3

HLP

200

3100

PROJECT D.F.E.

2'-6

"

8'-6

"

6"

MA

XIM

UM

6

'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0

"

3'-0"

FFE 10.06"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

ELEVATION VIEW

CEILING

HEIGHT

BOTTOM FEED

FEEDER AND

CONDUIT

SIDE FED FEEDER

AND CONDUIT

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

M

METRO PCS

METER & DISC

SWITCH

SEE E-201

NOTES 11 & 12

TO EXISTING

METRO PCS

EQUIPMENT

FOR CONTINUATION

SEE DWG. E-215

N E

ONE LINE DIAGRAM BUILDING 1

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #1

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS NOT

SUFFICIENT FOR TOP FEED.

NOTES:

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166110

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP2

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UH-2

STAIR CASE LIGHT

SPARE

SPARE

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

3 20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 2

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

ELEVATOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

30

DEVICE

PROTECTIVE

COMPACTOR

HOUSE

BUILDING 2

3PUMP

30

29

1003

603

1003

METER-FEED

1503

903

3

3

803

1503

1ST FL

3

2ND-7TH FL

402

40

90

APT E

APT B

2ND-7TH FL

APT D

2ND-7TH FL

APT C

2ND-7TH FL

APT A+B

2ND-7TH

APT FMAIN

PANEL

125

2ND-7TH FL

APT G+H

903

1ST FL

APT A

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 2

SPARE

HLP

SPARE

SPARE

SPARE

SPARE

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

30

29

UNIT HEATER

LP-2

1003

UNIT HEATER

2

2184

184

2003

1003

8'-6"

MA

XIM

UM

6'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0"

3'-0"

FFE 10.14"

2'-4"

6"

8'-0"

ELEVATION VIEW

CEILING

HEIGHT

PROJECT D.F.E.

BOTTOM FEED

FEEDER AND

CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

ELEVATION VIEW

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-216

1

2

3

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

2 SETS OF 500 KCML + 1#1/0 (G) - 4"C

2 SETS 4-350 KCML 1#1/0(G) - 3"C

3 SETS 4-500 KCML + 1#1/0 (G) - 4"C

KEY NOTES:

ONE LINE DIAGRAM BUILDING 2

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #2

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166111

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP3

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

SPARE

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 3

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

3

20

DEVICE

PROTECTIVE

BUILDING 3

3

3029

2003

803

3

3

3

803

903

PUMP

303

3

803

60

ELEVATOR

SPACE

COMPACTOR

1ST FL

APT A

50

2ND-7TH FL

APT C+D+E

2ND-7TH FL

APT G+H

2ND-7TH

APT F

2ND-7TH FL

APT D

2ND-7TH FL

APT E

80

2ND-7TH FL

APT C

150

2ND-7TH FL

APT A+B

20

1ST FL

APT B

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 3

HLP

SPARE

SPACE

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

SPARE

STAIR CASE LIGHT

UH-3

LP-3

SPACE

SPARE

803

1003

380

UNIT HEATER

2

2184

184

1003

HOUSE

PANEL

2003

PROJECT D.F.E.

8'-6"

MA

XIM

UM

6'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0"

3'-0"

FFE 12.72"

6"

8'-0"

ELEVATION VIEW

CEILING

HEIGHT

BOTTOM FEED

FEEDER AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-217

1

2

3

2 SETS OF 500 KCMIL + 1#1/0(G) - 4"C

2 SETS OF 4-350 KCMIL 1#1/0(G) - 3"C

5 SETS OF 4-500 KCMIL + 1#1/0(G) - 4"C

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 3

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #3

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166112

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP-4

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

UNIT HEATER

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

SPARE

LOAD (W)

LOAD (W)

1

1

1

1

2

2

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 4

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SPARE

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

3

60

DEVICE

PROTECTIVE

COMPACTORS

ELEV

BUILDING 4

3029

203

3

3

1003

1003

3

HOUSE FUSE

903

3

903

903

2ND - 7TH FL

3

2ND-7TH FL

1253

80

150

APT A+B

APT G+H

2ND-7TH

APT D

2ND-7TH FL

APT C

2ND-7TH FL

APT E

2ND-7TH

APT F

PANEL

PUMP

SHOP

30

100

60

SUP. AC

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 4

SPARE

HLP

SPARE

SPARE

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

SPARE

STAIR CASE LIGHT

RELOCATED EXISTING

LOAD

UH-4

1003 LP-4

184

184

SPARE

1003

2003

PROJECT D.F.E.

8'-6

"

6'-4

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0

"

3'-0"

FFE 9.62"

2'-9

"

6"

8'-3

"

ELEVATION VIEW

CEILING

HEIGHT

BOTTOM FEED FEEDER

AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-218

1

2

3

2 SETS OF 500 KCMIL + 1#1/0(G) - 4"C

2 SETS 4-350 KCMIL 1#1/0(G) - 3"C

5 SETS 4-500 KCMIL + 1#1/0(G) - 4"C

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 4

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #4

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166113

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP-5

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

SPARE

LOAD (W)

LOAD (W)

1

1

1

1

2

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

3 20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 5

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

DEVICE

PROTECTIVE

BUILDING 5

3029

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

DEVICE

PROTECTIVE

BUILDING 5

3029

ELEV.

603

COMPACTOR

603

903

3

2ND-7TH FL

150

APT A+B

2ND-7TH

APT D

2ND-7TH

APT F

SPACE

3

HOUSE

100

PANEL

80

3

2ND-7TH FL

APT C

903

2ND-7TH FL

APT E

CARP+KENNY

303

SHOPS

150

3

2ND-7TH

APT G+H

SPARE

SPACE

HLP

803

903

303

SPARE

STAIR CASE LIGHT

RELOCATED EXISTING

LOAD - LABEL 9

RELOCATED EXISTING

LOAD

UH-5

SPARE

LP-5

1003

403

SPARE SPARE903

303

UNIT HEATER

184

184

2

2003

1003

PROJECT D.F.E.

12'-9"

MA

XIM

UM

6'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0"

3'-0"

FFE 10.82"

1'-8

3

8

"

6"

8'-0"

ELEVATION VIEW

CEILING

HEIGHT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

12" M

IN

FIRE ALARM BOX

METER TOTALIZING

RELAY

BOTTOM FEED

FEEDER AND

CONDUIT

SIDE FED

FEEDER AND

CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

1

3

2

2

350KW 3P 4W

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS S

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

4

5

1200A AUTOMATIC

TRANSFER

SWITCH

PSE&G

1200A TRANS S

CABINET

1200A MAIN

SERVICE

SWITCH

5 5

600A 1200A SPARE

FOR CONTINUATION

SEE DWG. E-219

5

FOR CONTINUATION

SEE DWG. E-219A

1

2

3

4

5

2 SETS OF 4 #500 KCMIL + 1 #1/0(G) IN 4"C

2 SETS OF 4 #350 KCMIL + 1 #1/0(G) IN 3"C

4 SETS OF 4 #500 KCMIL + 1 #1/0(G) IN 4"C

6 SETS OF 4 #500 KCMIL + 1 #1/0(G) IN 4"C

4 SETS 4 #350 KCMIL + 1 #1/0(G) IN 3"C

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 5

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #5

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166114

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP-6

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

GAS CONTROL PUMP

VIA UPS

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

3 20

DEVICE

PROTECTIVE

360

356

1875

CA B

1440

1400

1400

1875391

BUILDING 6

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

B CA

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

COMPACTOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

3

60

DEVICE

PROTECTIVE

CHILD CARE

DISH WASH

DAY CARE

PUMP

ELEVATOR

LAUNDRY

BUILDING 6

3029

2003

803

3

2

3

903

303

903

3

903

3

2ND-7TH FL

1503

80

150

APT A+B

APT G+H

2ND-7TH

APT D

2ND-7TH FL

APT C

2ND-7TH FL

APT E

2ND-7TH

APT F

HOUSE PANEL

CENTER

MAL

100

2ND-7TH

40

100

AC

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 6

SPARE

SPACE

SPARE

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

SPARE

STAIR CASE LIGHT

380

UH-6

HLP

303

LP-6

SPACE SPACE

3

100

UNIT HEATER

2

2184

184

20

20

3200

3100

PROJECT D.F.E.

132.60"

MA

XIM

UM

6'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0"

3'-0"

FFE 10.7"

1'-9

5

8

"

6"

8'-0"

ELEVATION VIEW

CEILING

HEIGHT

NEW PULL BOX

ABOVE PANEL

BOARD

BOTTOM FEED

FEEDER AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-220

1

2

3

2 SETS OF 500 KCMIL + 1#1/0(G) - 4"C

2 SETS 4-350 KCMIL 1#1/0(G) - 3"C

3 SETS 4-500 KCMIL + 1#1/0(G) - 4"C

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 6

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #6

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166116

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP7

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

SPARE

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 7

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

2

DEVICE

PROTECTIVE

BUILDING 7

3029

903

903

2

3 150

3

903

3

HDP

COMP.

ELEV.

903

903

3

203

203

20

RELOCATED EXISTING

PUMP

HLP100

3

1ST FL

APT A+B

70

2

1ST FL

APT D

30

2ND-7TH FL

APT G+H

2ND-7TH

APT E

803

2ND-7TH

APT F

90

2ND-7TH

APT C

2ND-7TH

APT D

2ND-7TH FL

APT A+B

40

1ST FL

APT C

903

80

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 7

LP-7

HLP

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

SPARE

STAIR CASE LIGHT

LOAD

RELOCATED EXISTING

LOAD- LABEL 12

UH-7

RELOCATED EXISTING

LOAD - LABEL 14

3 100

SPACESPACE

3 200

UNIT HEATER

2

2184

184

PROJECT D.F.E.

8'-6

"

MA

XIM

UM

6

'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0

"

3'-0"

FFE 12.04"

1'-0"

6"

8'-0

"

ELEVATION VIEW

CEILING

HEIGHT

BOTTOM FEED

FEEDER AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

1

3

2

2

150W 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-221

1

2

3

2 SETS OF 500 KCMIL + 1#1/0(G) - 4"C

2 SETS 4#350 KCMIL 1#1/0(G) - 3"C

5 SETS 4-500 KCMIL + 1#1/0(G) - 4"C

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 7

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #7

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166117

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP-8

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

DEVICE

PROTECTIVE

360

356

1875

CA B

1875391

BUILDING 8

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

B CA

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

3

DEVICE

PROTECTIVE

BUILDING 8

3029

903

3

380

3

3

HDP

203

1003

3

3

1003

1003

20

(COMM.

COMP.

SPARE

ELEV.

2ND-7TH FL

APT A+B

150

3

2ND-7TH FL

APT D

90

2ND-7TH

APT E

903

KILN

100

HOUSE PANEL

2ND-7TH

APT F

2ND-7TH FL

APT C

100

2ND-7TH FL

APT G+H

CENTER)

1003

100

80

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 8

3

60

HLP

SPACE

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

SPARE

STAIR CASE LIGHT

RELOCATED EXISTING

LOAD

RELOCATED EXISTING

LOAD

RELOCATED EXISTING

LOAD

PUMP

SPARE

LP-8

UH-8

1003

903

2003

UNIT HEATER

2

2184

184

CCPP

PROJECT D.F.E.

2'-6"

8'-6"

6"

8'-0"

MA

XIM

UM

6'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0"

3'-0"

FFE 10.05"

ELEVATION VIEW

CEILING

HEIGHT

BOTTOM FEED

FEEDER AND CONDUITSIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-222

4

5

4

4

250KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

1200A

AUTOMATIC

TRANSFER

SWITCH

PSE&G

1200A TRANS "S"

CABINET

1200AS/1200AF

MAIN SERVICE

SWITCH

4 5

FOR CONTINUATION

SEE DWG. E-222

1

2

3

2 SETS OF 4#500 KCMIL + 1# 1/0(G) IN 4" C.

2 SETS OF 4#350 KCMIL + 1# 1/0(G) IN 3" C.

3 SETS OF 4#500 KCMIL + 1# 1/0(G) IN 4" C.

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

4

5

8 SETS OF 4#500 KCMIL + 1# 1/0G IN 4" C.

4 SETS OF 4#500 KCMIL + 1# 1/0G IN 4" C.

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 8

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #8

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

ONE LINE DIAGRAM BUILDING 8

166118

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP9

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

SPARE

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 9

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

B CA

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

DEVICE

PROTECTIVE

BUILDING 9

3029

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

B CA

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

DEVICE

PROTECTIVE

BUILDING 9

3029

402

HDP

903

903

3

903

803

1ST FL

90

APT D

2ND-7TH

APT C

2ND-7TH FL

APT G+H

2ND-7TH FL

APT D

2ND-7TH

APT E

503

1ST FL

APT E

302

1503

2ND-7TH

APT A+B

LP-9

1ST FL

APT A+B+C

3 80

2ND-7TH FL

APT F

SPARE

1003

ELEV.

903

PUMP

203

203

203

903

COMP.

HLP

SPARESPACE

SPARE

STAIR CASE LIGHT

RELOCATED EXISTING

LOAD

RELOCATED EXISTING

LOAD- LABEL 14

UH-9

1003

603

UNIT HEATER

2

2184

184

2003

PROJECT D.F.E.

1'-10

5

8

"

8'-6"

6"

8'-0"

MA

XIM

UM

6'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0"

3'-0"

FFE 10.65"

ELEVATION VIEW

CEILING

HEIGHT

BOTTOM FEED

FEEDER AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-223

1

2

3

2 SETS OF 4#500 KCMIL + 1# 1/0(G) IN 4" C.

2 SETS OF 4#350 KCMIL + 1# 1/0(G) IN 3" C.

3 SETS OF 4#500 KCMIL + 1# 1/0(G) IN 4" C.

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 9

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #9

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166120

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP10

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

3 20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 10

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

B CA

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

DEVICE

PROTECTIVE

BUILDING 10

3029

602

1503

402

3SPARE

203

203

1003

ELEV

1ST FL

APT A+B

2ND-7TH FL

APT A+B

803

2ND-7TH FL

APT C

903

2ND-7TH FL

APT E

100

3

20

3HDP

90

3ELEV

90

1ST FL

APT C

903

2ND-7TH

APT G+H

903

2ND-7TH

APT D

803

2ND-7TH

APT F

HLP

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 10

HOUSE PANEL

ELEVATOR

SPACE

LP-10

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

SPARE

STAIR CASE LIGHT

RELOCATED EXISTING

LOAD LABEL 10

SPARE

RELOCATED EXISTING

LOAD LABEL 11

903

UH-10

SPARE

SPARESPARE

LABEL 12

LABEL 14

3

100

UNIT HEATER

2

2184

184

3

100

3

200

PROJECT D.F.E.

1'-4

13

16

"

8'-6"

6"

8'-0"

MA

XIM

UM

6'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0"

3'-0"

FFE 11.1"

ELEVATION VIEW

CEILING

HEIGHT

BOTTOM FEED

FEEDER AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-224

1

2

3

2 SETS OF 4#500 KCMIL + 1# 1/0(G) IN 4" C.

2 SETS OF 4#350 KCMIL + 1# 1/0(G) IN 3" C.

3 SETS OF 4#500 KCMIL + 1# 1/0(G) IN 4" C.

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 10

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #10

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166121

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP-11

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 11

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANE LA

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

DEVICE

PROTECTIVE

BUILDING 11

3029

603

3

903

903

3

100

30PUMP

COMPACTOR

HOUSE FUSE

PANEL

ELEVATOR

HOUSE SECTION

1ST FL

APT A+B+C

903

1ST FL

APT D

403

3 125

2ND-7TH FL

APT G+H

3 90

2ND-7TH FL

APT D

3 80

2ND-7TH FL

APT F

1ST FL

303

APT E

1503

2ND-7TH

APT A+B

803

2ND-7TH

APT C

903

2ND-7TH

APT E

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 11

SPARE

HLP

SPARE

SPACE

SPARE

LP-11

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

SPARE

STAIR CASE LIGHT

UH-11

3 80

LABEL 10

203

1003

1003

UNIT HEATER

2

2184

184

3 200

PROJECT D.F.E.

2'-5

5

16

"

8'-6

"

6"

8'-0

"

MA

XIM

UM

6

'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0

"

3'-0"

FFE 10.06"

ELEVATION VIEW

CEILING

HEIGHT

BOTTOM FEED

FEEDER AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-225

1

2

3

2 SETS OF 4 #500 KCMIL + 1 #1/0(G) IN 4"C

2 SETS OF 4 #350 KCMIL + 1 #1/0(G) IN 3"C

3 SETS OF 4 #500 KCMIL + 1 #1/0(G) IN 4"C

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 11

BUILDING #11

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166122

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP-12

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 12

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

2

DEVICE

PROTECTIVE

BUILDING 12

3029

302

903

2

3

903

903

3

COMP.

903

903

3

203

203

90

1ST FL

APT D

70

2ND-7TH

APT G+H

HLP

PUMP

HDP

2ND-7TH FL

APT C

90

2ND-7TH FL

APT E

40

1ST FL

APT C

903

2ND-7TH

APT D

1ST FL

APT A+B

803

2ND-7TH

APT F

100

ELEV.

SHED

UK

1503 2ND-7TH FL

APT A+B

203

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 12

HLP

LP-12

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

SPARE

STAIR CASE LIGHT

RELOCATED EXISTING

LOAD LABEL 16

RELOCATED EXISTING

LOAD LABEL 18

SPARE

UH-12

1003

UNIT HEATER

2

2184

184

3

200

PROJECT D.F.E.

1'-0

"

8'-6

"

6"

8'-0

"

MA

XIM

UM

6

'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0

"

3'-0"

FFE 12.04"

ELEVATION VIEW

CEILING

HEIGHT

BOTTOM FEED

FEEDER AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-226

1

2

3

2 SETS OF 4 #500 KCMIL + 1/0(G) IN 4"C

2 SETS OF 4 #350 KCMIL + 1/0(G) IN 3"C

6 SETS OF 4 #500 KCMIL + 1/0(G) IN 4"C

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 12

BUILDING #12

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166123

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP-13

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

SPARE

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

3 20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 13

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

25

27

26

28

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

3

DEVICE

PROTECTIVE

BUILDING 13

3029

303

3

1503

3

903

603

200

70

ELEV.

COMPACTOR

2ND-7TH FL

APT A+B

401ST FL

APT C

1253

2ND-7TH

APT G+H

1ST FL

APT A+B

903

2ND-7TH

APT E

SPACE

903

2ND-7TH FL

APT D

203

1ST FL

APT D

803

2ND-7TH

APT F

903

HOUSE

SECTION

3 20TIMECLOCK

803

2ND-7TH FL

APT C

SURFACE

LOCATION :

MOUNTING :

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

COPPER BUS RATING: 400AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

BUILDING 13

SPACE

SPACE

LP-13

2

20

24

22

18

14

16

10

12

6

8

4

1

19

23

21

17

15

13

11

9

5

7

3

25

27

26

28

3029

SPARE

STAIR CASE LIGHT

RELOCATED EXISTING

LOAD

UH-13

RELOCATED EXISTING

LOAD

303

1003

UNIT HEATER

2

2184

184

HLP

1'-1

1

3

8

"

8'-6

"

6"

8'-0

"

MA

XIM

UM

6

'-1

1

2

"

NEW MAIN DISTRIBUTION PANEL

5'-0

"

3'-0"

FFE 10.55"

ELEVATION VIEW

CEILING

HEIGHT

PROJECT D.F.E.

BOTTOM FEED

FEEDER AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "A"

NEW 400A 3P 4W

SUB MAIN

DISTRIBUTION

PANEL "B"

NEW MAIN DISTRIBUTION PANEL

ELEVATION VIEW

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-227

1

2

3

2 SETS OF 4 #500 KCMIL + 1/0(G) IN 4"C

2 SETS OF 4 #350 KCMIL + 1/0(G) IN 3"C

6 SETS OF 4 #500 KCMIL + 1/0(G) IN 4"C

1. THE FEEDER CONDUIT SHALL BE

INSTALLED AS BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE MDP IS

NOT SUFFICIENT FOR TOP FEED.

NOTE:

KEY NOTES:

ONE LINE DIAGRAM BUILDING 13

JOHN LOPEZ

AMIT GULERIA

AS SHOWN

BUILDING #13

166124

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

03/08/2018

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

20

24

22

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

19

23

21

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : LPP14

SERVICE VOLTAGE:

COPPER BUS RATING: 200AMP

120/208 VOLT, 3 Ø, 4 WIRE 200AMP M.L.O

CKT.

25

27

29

26

28

30

ELECTRICAL ROOM ROOF

RECEPTACLE

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

EXH. FAN/DAMPER

STAIR CASE LIGHT

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE

SC RATING : 42KAIC

LIGHTING

UNIT HEATER

SPARE

LOAD (W)

LOAD (W)

1

1

1

1

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

1

1 1

1

1

1

20

20

20

20

20

1

1

1

1

1

1

20

1

20

1

20

20

20

20

20

20

20

20

20

20

20

20

20

120

120

120

1

1

2

20

20

20

3 20

DEVICE

PROTECTIVE

360

256

1875

CA B

1875391

BUILDING 14

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL A

SERVICE VOLTAGE:

COPPER BUS RATING: 400 AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

CKT.

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

3

DEVICE

PROTECTIVE

BUILDING 14

503

3

30

150

1ST FL

APT B

1503

2ND-7TH

APT G+H

1ST FL

APT A

1ST FL

APT C+D+E

403

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL B

SERVICE VOLTAGE:

CKT.

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

DEVICE

PROTECTIVE

BUILDING 14

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

B CA

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL C

SERVICE VOLTAGE:

CKT.

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

DEVICE

PROTECTIVE

BUILDING 14

SURFACE

LOAD

DESCRIPTION

CA B

2

CKT.

18

14

16

10

12

6

8

4

LOCATION :

MOUNTING :

1

BC

A

17

15

13

11

9

5

7

3

LOAD

DESCRIPTION

PANEL DESIGNATION : MAIN DISTRIBUTIOIN PANEL D

SERVICE VOLTAGE:

CKT.

ELECTRICAL ROOM FLOOR

SC RATING : 42KAIC

LOAD (W)

LOAD (W)

DEVICE

AMP.

TRIP

POLE

PROTECTIVE

POLE

AMP.

TRIP

DEVICE

PROTECTIVE

BUILDING 14

1

2

3

903

2ND-7TH

APT D

SPARE

SPARE

2ND-7TH FL

APT A+B

803

2ND-7TH FL

APT C

903

2ND-7TH FL

APT E

SPARE

803

2ND-7TH

APT F

803

HOUSE

SECTION

SPARE SPARE

COMPACTOR

EXISTING LOAD

1503

303

HOUSE FUSE

PANEL

3 100

3 30PUMP

LP-14

HLP

803

ELEV.

COMPACTOR

603

4 #500 KCMIL + 1/0G IN 4"C

2 SETS OF 4 #500 KCMIL

1/0(G) IN 4"C

2 SETS OF 4 #350 KCML 1/0(G)

IN 3"C

UH-14

1. THE FEEDER CONDUIT

SHALL BE INSTALLED AS

BOTTOM OR SIDE FEED

WHERE CLEARANCE ABOVE

MDP IS NOT SUFFICIENT

FOR TOP FEED.

NOTE:

COPPER BUS RATING: 400 AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

3 100

COPPER BUS RATING: 400 AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

COPPER BUS RATING: 400 AMP

120/208 VOLT, 3 Ø, 4 WIRE 400 AMP M.L.O

SPARE

SPARE

UNIT HEATER

2

2184

184

2003

KEY NOTES:

3'-1

3

16

"

8'-6"

6"

6'-2

11

16

"

NEW MAIN DISTRIBUTION PANEL

FFE 9.4"

ELEVATION VIEW

CEILING

HEIGHT

PROJECT D.F.E.

BOTTOM FEED

FEEDER AND CONDUIT

SIDE FED FEEDER

AND CONDUIT

1

3

2

2

150KW 3PHASE 4WIRE

NATURAL GAS

GENERATOR

600A AUTOMATIC

TRANSFER

SWITCH

PSE&G

800A TRANS "S"

CABINET

800AS/600AF

MAIN SERVICE

SWITCH

2 3

FOR CONTINUATION

SEE DWG. E-228

ONE LINE DIAGRAM BUILDING 14

BUILDING #14

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 82N

D S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 83T

H S

T.

BE

AC

H 82N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86T

H S

T.

BE

AC

H 81S

T S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

166125

03/08/2018

1. FIRE ALARM CONTRACTOR MUST PRODUCE A SEPARATE FIXED PRICE TO

PERFORM THE SCOPE OF WORK CONTAINED ON THIS DRAWINGS IN

CONNECTION WITH THE FIRE ALARM SYSTEM. THESE DRAWING ARE PROVIDED

FOR BID PURPOSES AND TO ILLUSTRATE THE SCOPE OF WORK OF THIS

PROJECT. PRIOR TO SUBMISSION OF THE FIRE ALARM SYSTEM BID, THE FIRE

ALARM VENDOR IS RESPONSIBLE TO REVIEW ALL DRAWINGS (i.e. MECHANICAL,

ELECTRICAL, PLUMBING & ARCHITECTURAL ). UPON SUBMISSION OF FIRE ALARM

BID, THE FIRE ALARM VENDOR CERTIFIES THAT ALL DRAWINGS HAVE BEEN

REVIEWED. THE SITE HAS BEEN VISITED/INSPECTED, AND THAT ALL LOCAL FIRE

MARSHALL REQUIRED ITEMS ARE FULLY UNDERSTOOD AND INCLUDED IN THE

BID PRICE (NO CHANGE ORDER ALLOWED.)

2. FIRE ALARM VENDOR MUST ADHERE TO ALL NEW YORK CITY CODES AND

AUTHORITIES HAVING JURISDICTION (BUILDING DEPT. FIRE MARSHALL ETC.). THE

ENTIRE SYSTEM MUST BE DESIGNED IN ACCORDANCE WITH THIS AUTHORITIES

HAVING JURISDICTION.

3. FIRE ALARM VENDOR MUST SUBMIT TO THE ENGINEER & OWNER. FINAL ( AS

APPROVED BY THE LOCAL BLDG. DEPT. & FIRE MARSHALL ) SIGNED & SEALED BY

ANY LICENSED PE DESIGN/BUILD DRAWINGS INCLUDING FIRE ALARM RISER

DIAGRAM, LAYOUT, EQUIPMENT LIST, SPECIFICATION PRIOR TO START OF

INSTALLATION. THE COST OF THE ENGINEERING FEE, PROGRAMMING CHARGE,

NEW EQUIPMENT, CONNECTION & TESTING, TROUBLE SHOOTING OF THE

SYSTEM ATTENDANCE OF THE FIRE ALARM INSPECTION ARE TO BE PART OF THE

TOTAL PRICE. INSTALLATION OF THE NEW FIRE ALARM SYSTEM NOT ONLY BEGIN

UPON WRITTEN APPROVAL FROM THE ENGINEER.

4. ALL CABLES AND WIRING MUST BE PLENUM FIRE ALARM RATED NEC TYPE FPLP

RATED CABLES.

5. LOCATION OF THE FIRE ALARM DEVICES (HORNS, STROBES, ETC.) INDICATED ON

THIS DRAWING ARE TO BE USED IN ADDITION TO THE LOCAL FIRE MARSHALL'S

ORDINANCE. DESIGN OF THE ENTIRE SYSTEM MUST BE IN ACCORDANCE WITH

THE NEW YORK CITY DEPARTMENT 2014 BUILDING AND FIRE CODES. DEVICES OR

DOCUMENTS ADDED AT THE REQUEST OF THE FIRE MARSHALL OR BLDG.

DEPARTMENT WILL BE REIMBURSED UNDER

CONTRACT UNIT PRICING.

FIRE ALARM NOTES

THE CONTRACTOR IS RESPONSIBLE TO COORDINATE EQUIPMENT

ALTERNATES WITH OTHER TRADES AND MAKE ADJUSTMENTS

TO THE FIRE ALARM SYSTEMS AS REQUIRED TO ACCOMMODATE

THESE NEW ALTERNATES.

THE CONTRACTOR IS RESPONSIBLE TO SUBMIT ALL OF THE FOLLOWING

ITEMS FOR REVIEW/APPROVAL BY NO MORE THAN 3 WEEKS AFTER THE

CONTRACTOR'S CONTRACT/BID HAS BEEN AWARDED. ALL SUBMITTALS

MUST BE SENT TOGETHER AS A SINGLE PACKAGE WITH MANUFACTURER’S

SPECIFIC MODELS AND SPECIFICATIONS OUTLINED TO MATCH THE

SCHEDULED REQUIREMENTS, EACH SUBMITTAL MUST BE LABELED WITH

THE UNIT DESIGNATION USED WITHIN THIS DRAWING SET. IF THE

SUBMITTAL PACKAGE IS FOUND TO BE INCOMPLETE UPON RECEIPT,

THE PACKAGE WILL BE HELD AND WILL NOT BE REVIEWED UNTIL THE

REMAINDER OF THE PACKAGE IS RECEIVED. SIX (6) HARD COPIES OF

THE SUBMITTAL PACKAGE MUST BE SENT TO AG CONSULTING

ENGINEERS, INC.

SHOP DWGS/EQUIPMENT SUBMITTALS FIRE

ALARM NOTES

FIRE ALARM CONTROL PANEL

FIRE ALARM SYMBOLS

MANUAL PULL STATION

SMOKE DETECTOR

END OF LINE RESISTOR

DIGITAL ALARM COMMUNICATOR TRANMITTER

S

FACP

DACT

FIRE ALARM CUTOUT BOXFCB

F

F

PULL STATION & STROBE

FIRE ALARM

CONTROL PANEL

S S

F

ROOF FLOOR

ELECTRICAL ROOM

MM MM

GENERATOR

CONTROLLER

6 POLE

FCO

DACT

TO EXISTING TELEPHONE DEMARC IN THE FIRE

FLOOR FOR SIGNAL TO CENTRAL MONITORING

SATION. CONTRACTOR SHALL REQUEST TWO

DEDICATED PHONE LINES FROM THE UTILITY

COMPANY.

TWO DEDICATED

TELEPHONE LINES

GENERATOR ROOM

ENTRANCE HALL

S

FUSED DISCONNECT

SWITCH (TYP)

3P, 30A TRANSFER

SWITCH

E N

L

FUSE

CUTOUT BOX

4 #10AWG + 1 #10G IN 3/4"C

4 #10AWG + 1 #10G IN 3/4"C

120/208V, 3P, 4W TAP AHEAD

OF MAIN SERVICE SWITCH

REFER TO FIRE ALARM DISCONNECT SWITCH DETAIL 1, IN DWG. FA-001.00.

PROVIDE NUMBER OF POLES AS REQUIRED.

KEY NOTES:

THE FIRE ALARM SYSTEM SHALL PERFORM AS DESCRIBED BELOW. ALL

EQUIPMENT, COMPONENTS AND DEVICES ASSOCIATED WITH THE FIRE ALARM

SYSTEM SHALL BE M.E.A. APPROVED. THE ENTIRE SYSTEM SHALL CONFORM TO

ALL NEW YORK CITY BUILDING CODES AND LOCAL LAWS.

1. FIRE DETECTION SHALL BE ACCOMPLISHED BY:

A. ACTIVATION OF A MANUAL PULL STATION.

B. ACTIVATION OF AN AREA SMOKE DETECTOR.

2. OPERATION OF PULL STATION SHALL BE COMMUNICATED AS A "MANUAL

ALARM" TO THE CENTRAL STATION THROUGH THE DACT.

3. ACTIVATION OF ANY SMOKE DETECTOR SHALL BE COMMUNICATED AS AN

"AUTOMATIC ALARM" TO THE CENTRAL STATION THROUGH THE DACT.

4. ACTIVATION OF ANY FIRE DETECTION DEVICE SHALL BE DISPLAYED AT

THE FIRE ALARM CONTROL PANEL.

5. GENERATOR RUN AND FAIL STATUS SHALL BE DISPLAYED AT THE FIRE

ALARM CONTROL PANEL.

SEQUENCE OF OPERATION FOR THE FIRE

ALARM SYSTEM:

1. REFER TO DRAWING FA-001.00 FOR SYMBOL LIST, GENERAL NOTES AND ABBREVIATIONS.

2. REFER TO FLOOR PLANS FOR EXACT QUANTITIES OF DEVICES.

3. ALL EQUIPMENT AND ITS INSTALLATION SHALL COMPLY WITH NFPA 72, BC-907 OF THE N.Y.C.

BUILDING CODE, MEA. AND NYC. FIRE DEPARTMENT, AND SHALL BE UL LISTED FOR ITS INTENDED

USE.

4. FIRE ALARM SYSTEM POWER SOURCE SHALL BE FROM A DEDICATED UNSWITCHED CIRCUIT AND

SHALL BE EQUIPPED WITH A BATTERY BACK UP.

5. LOCATIONS OF DEVICES AND EQUIPMENT ARE APPROXIMATE. FINAL LOCATIONS MUST BE

COORDINATED WITH OWNER ACCORDING TO THE FIELD CONDITIONS.

6. THIS IS NOT A POINT-TO-POINT WIRING DIAGRAM. THIS DIAGRAM IS FOR ESTIMATING PURPOSES

ONLY. PRIOR TO STARTING ANY WORK, A WORKING POINT-TO-POINT WIRING DIAGRAM SHALL BE

OBTAINED FROM THE BUILDING FIRE ALARM VENDOR.

7. CIRCUIT WIRING FROM THE FIRE ALARM CONTROL PANEL TO THE SYSTEM PERIPHERAL EQUIPMENT

SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS WITH A MINIMUM AS FOLLOWS.

A. EACH ADDRESSABLE DATA COMMUNICATIONS CIRCUIT: TWO (2) CABLES, EACH WITH TWO (2)

#14 AWG TWISTED AND SHIELDED CONDUCTORS.

B. EACH ALARM INITIATING SUPERVISORY OR STATUS MONITORING CIRCUIT FROM A MONITOR

ZONE ADDRESSABLE MODULE (MM): TWO (2) #14 AWG CONDUCTORS.

C. EACH CONTROL CIRCUIT: TWO (2) #14 AWG CONDUCTORS.

8. MANUAL PULL STATIONS SHALL BE MOUNTED AT 4'-0" A.F.F.

9. FUSE CUTOUT BOXES SHALL COMPLY WITH N.Y.C. BUILDING CODE BC-907 AND HAVE A REMOVABLE

SOLID COPPER NEUTRAL BAR.

10. ALL CONDUITS AND CONTROL PANELS SHALL BE GROUNDED TO THE WATER MAIN WITH A MINIMUM

#6 AWG CONDUCTOR.

11. EACH FIRE ALARM INITIATING AND INDICATING CIRCUIT SHALL BE ELECTRICALLY SUPERVISED.

12. ALL CONTROL PANELS, FUSE CUTOUTS AND SILENCE SWITCHES SHALL BE PROPERLY LABELED

WITH MINIMUM 1/4" HIGH LETTERS.

13. ALL WIRING SHALL BE IN MINIMUM 3/4" RGS CONDUIT. PROVIDE THE NUMBER OF CONDUITS AS

REQUIRED. CONDUIT FILL SHALL BE AS FOLLOWS:

A. 3/4" CONDUIT: UP TO 4 PAIRS FA CABLES OF ALL TYPES.

B. 1" CONDUIT: UP TO 8 PAIRS OF FA CABLES.

14. IF THERE IS A DISCREPANCY IN QUANTITIES OF ELEMENTS BETWEEN RISER DIAGRAM AND PLANS,

THE MORE QUANTITIES SHOWN EITHER ON PLAN OR RISER SHALL GOVERN.

15. ALL CONDUCTORS SHALL BE FDNY APPROVED, PLENUM RATED TYPE FPLP.

16. "FACP" TO BE LOCATED IN BLDG. MAIN LOBBY. EXACT LOCATION TO BE DETERMINED IN FIELD, AS

DIRECTED BY CONSTRUCTION MANAGER.

17. "FACP" POWER TO BE AS INDICATED ON THE DRAWING.

18. FOR FIRE ALARM CONTROL PANEL USE EDWARDS E-FS502 PANEL OR APPROVED EQUAL.

19. PROVIDE ALARM RELAY ON FIRE ALARM CONTROL PANEL FOR SECURITY PANEL LOCATIONS. SEE

SECURITY DRAWINGS FOR MORE INFORMATION.

FIRE DETECTION AND ALARM SYSTEM RISER

NOTES:

FIRE ALARM SYSTEM -RISDER DIAGRAM

TYPICAL FOR BUILDING NO.1 TO 14

WIRING NOTES

MULTI-CONDUCTOR CABLING RUN IN RACEWAY SHALL

MEET THE FOLLOWING REQUIREMENTS.

1. A MINIMUM TEMPERATURE RATING OF 150 °C.

2. A MINIMUM AVERAGE INSULATION THICKNESS OF

15MIL.

3. A MINIMUM AVERAGE JACKET THICKNESS OF 25

MILS.

4. THE COLOR OF THE CABLE SHALL BE RED.

5. THE CABLE SHALL BE A TYPE FPLP (PLENUM TYPE )

SINGLE CONDUCTOR CABLING RUN IN EMT CONDUIT

SHALL MEET THE FOLLOWING REQUIREMENT.

1. A MINIMUM TEMPERATURE RATING OF 90 °C.

2. A MINIMUM VOLTAGE RATING OF 600V. .

FIRE ALARM MATRIX

FIRST FLOOR

G

GAS LEAK DETECTOR

Key/Location Plan

Drawing Title:

Contract No.:

Drawing No.:

Scale:

Date:

Checked By:

Drawn By:

Seal & Signature:

Contract Title:

-

Sheet of

TEL.(212)290-1444 FAX.(212)290-142548 West 37th St. New York, NY 10018

BE

AC

H 8

2N

D S

T.

BE

AC

H 83

TH

S

T.

BE

AC

H 84

TH

S

T.

BE

AC

H 85

TH

S

T.

BE

AC

H 85T

H S

T.

BE

AC

H 84T

H S

T.

BE

AC

H 8

3T

H S

T.

BE

AC

H 8

2N

D S

T.

R O

C K

W A

Y B

E A

C H

B

O U

L E

V A

R D

BE

AC

H 86

TH

S

T.

BE

AC

H 81

ST

S

T.

H A M M E L B O U L E V A R D

HAMMEL BOULEVARD

12

10

11

5

13

14

9

3

6

7

1

4

2

8

Block No.:

E.D.P. No.:

Development No.:

Zone No.:

Lot No.:

Zoning Map No.:

Development:

Building Address:

Building No.(s):

Borough of: ORACLE No.:

LANGAN21 Penn Plaza, Eighth FloorNew York, NY 10001TEL: (212) 479-5400FAX: (212) 479-5444

AG CONSULTING ENGINEERING, PC131 West 33rd Street, Suite 12BNew York, NY 10001TEL: (212) 268-0950

CONSTRUCTIONPERMIT SERVICES63 W 38th St #15, New York,NY 10018TEL: (212) 246-5111

J. MARTIN8 Armour Rd, Mahwah, NJ 07430TEL: (201) 529-5585

CAMERON ENGINEERING45 W 36th St,New York, NY 10018TEL: (212) 324-4000

COSENTINI ASSOCIATES2 Pennsylvania Plaza,New York, NY 10121TEL: (212) 615-3600

32 Broadway, Eighth FloorNew York, NY 10004TEL: (212) 971-0936

SHEN MILSOM WILKE417 5th Ave, New York, NY 10016TEL: (212) 725-6800

HOWARD L. ZIMMERMANARCHITECTS, PC11 West 30th Street,New York, NY 10001TEL: (212) 564-9393

Consultants: ELLANA

TEL. 212.306.4247 FAX 212.306.8542

PROGRAM UNIT:

138 167

-

AS SHOWN

AMIT GULERIA

MARJORY MITCHELL

03/08/2018

Hollow Bar and Accessories 

Technical Hotline: 1‐866‐875‐9546  |  [email protected]  www.skylinesteel.com 

Commercial Grade Hollow Bar and Accessories 

Average Inner Diameter 

      “T” Threaded Hollow Bar Systems       

Bar   Designation 

Nominal   Outer Diameter 

in 

(mm) 

Average   Inner Diameter 

in 

(mm) 

Cross   Sectional Area 

in2 (mm2) 

Ultimate   Load 

kips 

(kN) 

Yield   Load 

kips 

(kN) 

Approx. Major  Thread Diameter 

in 

(mm) 

Nominal   Weight 

lbs/ft 

(kg/m) 

T30/11 1.18 30  0.43 

11 0.64 413  72.0 320  58.5 260  1.30 

33 2.2  3.3 

T40/20 1.57 40  0.79 

20 1.13 726  121.4 540  95.6 425  1.70  

43.2 3.8  5.6 

T40/16 1.57 40  0.63 

16 1.40 903  148.4 660  118.1 525  1.70  

43.2 4.8  7.2 

T52/26 2.05 52 

1.03 26 

1.94 1251 

208.0 925 

170.0 756 

2.20 55.9 

6.7 9.9 

T76N 3.00 76  2.00 

51 3.35 2161 

319.0 1418  252.0 1120  3.20  81.3 

10.2  15.2 

T76S 3.00 76 

1.77 45 

4.03 2600 

418.0 1859  330.0 1467  3.20  81.3 

13.2  19.7 

T103/78 4.06 103  3.00 

78 4.87 3142 

510.5 2270  404.8 1800  4.20 106.7 

17.0  25.3 

T103/51 4.06 103  2.00 

51 8.80 5677 

823.0 3660  600.4 2670  4.20 106.7 

30.0  44.6 

Nominal  Outer Diam- 

eter 

Hollow Bar and Accessories 

Technical Hotline: 1‐866‐875‐9546  |  [email protected]  www.skylinesteel.com 

Average Inner  Diameter 

      “R” Threaded Hollow Bar       

Bar   Designation 

Nominal Outer  Diameter 

in (mm) 

Average Inner  Diameter 

in (mm) 

Effective Outer  Diameter 

in (mm) 

Cross    Sectional Area 

in2 (mm2) 

Ultimate  Load 

kips 

(kN) 

Yield   Load 

kips 

(kN) 

Approx. Major  Thread Diameter 

in 

(mm) 

Nominal  Weight 

lbs/ft 

(kg/m) 

R32S 1.26 32  0.63 16  1.15  

29.1 0.76 488  81 360  62 

275 1.38 35  2.700  

4.00 

R38Nx19mm OD 1.50 38  0.75 19  1.41  

35.7 1.11 717  112 498  86 

382 1.62 41  3.415  

5.08 

R51N 2.01 51  1.30 33  1.88  

47.8 1.46 939  177 787  141 627  2.13 54  5.700  

8.50 

Please note: As we continuously improve the design of our products, product details are subject to change. 

Commercial Grade Hollow Bar and Accessories 

  Couplers  Hex Nuts 

 

“T” Threaded Hollow Bar Couplers    “T” Threaded Hollow Bar Hex Nuts 

Bar 

Designation OD in 

(mm) 

L in 

(mm) 

Weight lbs 

(kg) Bar 

Designation A in 

(mm) 

B in 

(mm) 

Weight lbs 

(kg) 

T30/11 1.5 38  4.2 

105 1.0 0.45  T30/11 

1.8 46.0 

1.4 36.0 

1.0 0.45 

T40/20 2.1 53  5.5 

140 2.6 1.18  T40/20 

2.5 64.0 

2.0 50.0 

2.7 1.22 

T40/16 2.1 53  5.5 

140 2.6 1.18  T40/16 

2.5 64.0 

2.0 50.0 

2.6 1.18 

T52/26 2.7 68.5 

6.25 160  5.2 2.36  T52/26 

3.2 81  2.5 63.5 

5.1 2.31 

T76N 3.8 97  8.0 

200 10.2 4.54  T76N 

4.0 102.0 

3.1 80.0 

6.2 2.81 

T76S 3.8 97  8.7 

220 14.4 6.53  T76S 

4.0 102.0 

3.1 80.0 

6.2 2.81 

T103 5.2 132 

11.5 292  30.5 13.8  T103 

5.25 133.0  5.125 130  13.0 5.90 

“R” Threaded Hollow Bar Couplers  “R” Threaded Hollow Bar Hex Nuts 

A  B 

Nominal  Outer Diam- 

eter 

Hollow Bar and Accessories 

Technical Hotline: 1‐866‐875‐9546  |  [email protected]  www.skylinesteel.com 

Bar   Designation 

OD 

in 

(mm) 

in 

(mm) 

Weight 

lbs 

(kg) 

 Bar   

Designation 

in 

(mm) 

in 

(mm) 

Weight 

lbs 

(kg) 

R32S 1.7 43 

7.5 190 

2.0 0.91  R32S 

1.8 46.0 

3.0 65.0 

2.0 0.91 

R38Nx19mm  2.5 64 

8.7 220 

3.8 1.72  R38Nx19mm  

2.0 51.0 

2.0 60.0 

1.3 0.59 

R51N 2.5 64 

8.0 200 

4.2 1.91  R51N 

3.0 76.0 

3.0 70.0 

3.5 1.59 

Please note: As we continuously improve the design of our products, product details are subject to change. 

Domestic Hollow Bar and Accessories 

Average Inner  Diameter 

      “T” Threaded Hollow Bar Systems*       

Bar   Designation 

Nominal Outer  Diameter 

in (mm) 

Average Inner  Diameter 

in (mm) 

Cross   Sectional Area 

in2 (mm2) 

Minimum   Ultimate Load 

kips 

(kN) 

Minimum  Yield Load 

kips 

(kN) 

Approx. Major  Thread Diameter 

in 

(mm) 

Nominal Weight 

lbs/ft (kg/m) 

T40/16 1.57 40 

0.63 16 

1.36 879 

148 660 

118 525 

1.625 41.3 

4.9 7.3 

T40/20 1.57 40  0.79 20  1.23 800  127 606  110 

489 1.625 41.3 

4.4 6.5 

T52/26 2.05 52 

1.03 26 

2.07 1337 

227 1009 

179 796 

2.125 54.0 

6.8 10.1 

T76N 3.00 76  2.10 

52 3.20 2065  319 1418  252 

1120 3.000  76.2 

11.1  16.5 

T76S 3.00 76  1.77 45  3.90 2516  418 1859  330 

1467 3.000  76.2 

13.2  19.7 

  Couplers  Anchor Hex Nuts 

 L OD 

A  A 

Nominal  Outer Diam- 

eter 

Hollow Bar and Accessories 

Technical Hotline: 1‐866‐875‐9546  |  [email protected]  www.skylinesteel.com 

“T” Threaded Hollow Bar Couplers* 

Bar 

Designation 

OD 

in 

(mm) 

in 

(mm) 

Weight 

lbs 

(kg) 

HBC PL 40 2.500 63.5 

5.50 139.7 

5.10 2.31 

HBC PL 52 3.125 79.375 

6.00 152.4 

11.39 5.17 

HBC PL 760 3.75 95.25 

7.875 200.03 

34.81 15.79 

 

“T” Threaded Hollow Bar Anchor Hex Nuts* 

Bar 

Designation 

in 

(mm) 

in 

(mm) 

Weight 

lbs 

(kg) 

HBHN 40 2.50 63.5 

2.0 50.8 

5.87 2.66 

HBHN 52 3.35 85.09 

3.0 76.2 

10.04 4.55 

HBHN 760 4.00 101.6 

3.1 78.7 

23.81 10.80 

 

* Meets “Buy America” requirements 

Hollow Bar Bits 

Carbide Cross, Steel Cross Cut , and Button Bits  

Bar 

Sizes 

Size  

in 

(mm) 

Weight 

lbs/unit 

(kg/unit) 

T30  2.0 50.8 

1.0 0.45 

2.5 63.5 

2.0 0.91 

3.0 76.2 

2.9 1.32 

T40  2.5 63.5 

2.0 0.91 

3.0 76.2 

2.9 1.32 

3.5 88.9 

3.5 1.59 

4.0 101.6 

5.5 2.49 

4.5 114.3 

7.0 3.18 

5.0 127.0 

10.5 4.76 

6.0 152.4 

13.0 5.90 

T52  4.5 114.3 

7.0 3.18 

5.0 127.0 

10.5 4.76 

6.0 152.4 

13.0 5.90 

T76  5.0 127.0 

10.5 4.76 

6.0 152.4 

13.0 5.90 

Hollow Bar and Accessories 

Technical Hotline: 1‐866‐875‐9546  |  [email protected]  www.skylinesteel.com 

7.0 177.8 

14.5 6.58 

8.0 203.2 

16.0 7.26 

R32  2.0 50.8 

1.0 0.45 

2.5 63.5 

2.0 0.91 

3.0 76.2 

2.9 1.32 

R38  3.0 76.2 

2.9 1.32 

3.5 3.5 1.59 

R51  4.0 101.6 

5.5 2.49 

4.5 114.3 

7.0 3.18 

5.0 127.0 

10.5 4.76 

6.0 152.4 

13.0 5.90 

All bits subject to availability.  Call for stock quantities. Specialty bits available upon request. 

Drill Bit Adap tors 

Adaptors 

Weight 

lbs/unit 

(kg/unit) 

R32 x R38 0.20 0.09 

R38 x R51 0.30 0.13 

T30 x T40 0.30 0.13 

Call for job specific quotes ‐ Price depends on quantities 

 

Hollow Bar 

and 

Accessories 

Technical Hotline: 1‐866‐875‐9546  |  

[email protected]  www.skylinesteel.com 

 

 

 

Technical Hotline: 1‐866‐875‐9546  |  [email protected]  www.skylinesteel.com 

Product Detail: Hollow Bar Systems 

Hollow Bars Hollow bars are fully threaded, “disposable” drill rods capable of drilling holes utilizing sacrificial bits that will advance the drill 

string to the required depth and then allow them to be grouted in place. This process creates the steel reinforcing portion of an 

anchor or pile. Hollow bar products are a valuable and multi‐functional addition to the geotechnical contractor’s toolbox. They 

can be used as tie back or tie down anchors, rock anchors, soil nails and micropiles in a large array of challenging applications. 

There are three basic types of drill bits for use with hollow bars: versatile cross cut bits in carbide or hardened steel, button bits 

for intact rock in carbide or hardened steel and steel stepped clay bits for cohesive soils. The selection of the drill bit type and 

size is based on the material that is being drilled through and the desired borehole diameter. A larger borehole diameter provides 

greater load carrying capacity and greater grout cover. Grout cover protects the anchor rod from corroding. Depending on the 

actual soil type, a 2.5 inch diameter bit can produce a 6 to 8 inch diameter grout column. 

Production rates are increased through the use of hollow bar systems, as compared to traditional solid bar anchors. This is 

especially true when drilling through difficult conditions. In sites with low headroom, large scale drilling rigs and hole casing 

systems can be avoided. With drill rigs where “through the head grouting” is not available, grout swivels can be used to retrofit 

standard rotary percussion drills. 

Hollow Bar Corrosion Protection The level of corrosion protection is dependent on the anticipated service life of the anchor, installation methods, and the 

corrosion potential (aggressiveness) of the environment. The FHWA has studied the effects of installation on both galvanized 

and epoxy coated bars as reported in FHWA CFL/TD10‐002. This study revealed epoxy coatings were both partially and 

completely removed at the leading edge of the screw profile and around the couplings. 

The installations were constructed using hollow bars as both the drill rod and reinforcement. The effects of the removal 

reduced the service life of the bar substantially by creating concentrated locations for potential corrosion. As such, the designer 

should evaluate all possibilities when determining the level of corrosion protection required. 

 

Technical Hotline: 1‐866‐875‐9546  |  [email protected]  www.skylinesteel.com 

Hot Dipped Galvanizing 

Hot dipped galvanizing is a form of galvanization and is the process of coating a 

base metal such as steel with molten zinc. The zinc acts as a sacrificial material to 

the steel. The galvanized coating is manufactured in accordance with ASTM A 53 

standards and is more resistant to handling than epoxy coatings.  

Sacrificial Steel 

Using sacrificial steel as a form of corrosion protection requires a geotechnical 

evaluation of the corrosivity of the soils. The estimated loss of steel thickness is 

calculated and then the hollow bar is designed with the additional increase in 

thickness.