University of Groningen
Predictability of clinical wear by laboratory wear methods for the evaluation of dentalrestorative materialsHeintze, Siegward Dietmar
IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite fromit. Please check the document version below.
Document VersionPublisher's PDF, also known as Version of record
Publication date:2010
Link to publication in University of Groningen/UMCG research database
Citation for published version (APA):Heintze, S. D. (2010). Predictability of clinical wear by laboratory wear methods for the evaluation of dentalrestorative materials. Groningen: [s.n.].
CopyrightOther than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of theauthor(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).
Take-down policyIf you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediatelyand investigate your claim.
Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons thenumber of authors shown on this cover page is limited to 10 maximum.
Download date: 19-07-2020
11
Chapter 1
General Introduction
12
Phenomenology of wear In the history and evolution of humankind, wear of human teeth was always present and
regarded as physiological. The extent of wear was mostly related to nutritional habits,
which changed over time. Teeth that were so heavily worn that they did not demonstrate
any anatomical tooth morphology were often found in human skulls that date back as early
as 160,000 years ago (www.sfgate.com/cgi-bin/article.cgi?f=/c/a/2003/06/12/FOSSIL.
TMP&type= science). The wear was most likely related to the uncooked food, which was
eaten at that time and which was very abrasive like roots, plants, cereals etc; additionally
the food contained fragments of bone, collagenous material of fish and meat.
From a scientific standpoint, people paid attention to wear and friction mechanisms
already in the 18th century, when they examined the teeth of patients as well as the teeth
of skulls. John Hunter from Glasgow, Scotland, described in one of the first textbooks in
dentistry The Natural History of Human teeth. Explaining their Structure, Use, Formation,
Growth and Diseases (1771) three modes of tooth wear: abrasion, attrition and erosion [1].
The science of the interaction between materials under action is called “tribology” (from
Greek tribo = to rub). Historically, Leonardo da Vinci (1452-1519) was the first to formulate
two laws of friction. According to his findings, the frictional resistance was the same for two
different objects of the same weight, even if they make contacts over different widths and
lengths. He observed that the force required to overcome friction was doubled when the
weight was doubled. Similar observations were made by Charles-Augustin de Coulomb
(1736-1806). However, it was only in the ninenteen-sixties, when increased emphasis was
placed on tribological concepts following The Jost Report [2], in which vast sums of money
were reported to be lost in the UK annually due to the consequences of friction, wear and
corrosion (erosion). As a result, several national centres for tribology were set up in the UK
and elsewhere. Since then, the term has diffused into the international engineering field
and tribology has become a major part of applied sciences, embracing material sciences,
physics, chemistry and mechanical engineering. Moreover, international journals like
”WEAR“, “Journal of Engineering Tribology”, “Journal of Tribology”, ”Tribology and
interface engineering series“ and others were set up to cover phenomena related to the
wear of materials.
In 1969 the International Research Group on Wear of Engineering Materials put together a
glossary of terms and definitions for the field of tribology. The glossary is included in the
“Wear Control Handbook” of the American Society of Mechanical Engineering (ASME) [3].
It contains definitions of 500 general tribological terms in eight languages. In this handbook
13
wear is defined as the progressive loss of substance from the operating surface of a body,
occurring as a result of relative motion at the surface.
There are different forms of wear according to different mechanisms and forms of
interaction between materials. However, there is no internationally accepted ISO norm
about the different types of wear. A norm by the German Institute of Industrial Norms (DIN
No 50320) was withdrawn in 1997 [4]. In this norm, the following mechanisms were
defined: adhesion, abrasion, surface fatigue, and tribochemical processes. This
classification is based on Burwell [5]. The definitions of these mechanisms have not
changed over the years. Adhesion means the formation and separation of interface
bonding systems (e.g. cold soldering). Abrasion means material wear due to the
scratching or cutting strains of two materials, where one of the surfaces is considerably
harder than the other. Surface fatigue is the fatigue and crack formation on surface areas
due to tribological strains, leading to gross mechanical failure. By contrast, chemical
reactions of the interacting materials or the surrounding medium cause tribochemical
processes. As a consequence of tribological interactions, abrasive particles are formed
(Figure 1).
Figure 1: Tribological interactions and wear mechanisms according to [6].
Tribological interactions
Stress interactions
(load, friction)
Frictional heating
Material interactions
Surface fatigue Abrasion Tribochemical reactions
Adhesion
Stress cycles Microstructural changes
Crack formation Delamination
Fatigue wear particles
Micro-cutting Micro-ploughing Micro-cracking
Abraded wear particles
Tribochemiocal films (material/
environment interactions)
Tribochemical wear particles
Transferred material (adhesive joint
formation/rupture)
Adhesive wear particles
14
Human teeth: their components and physical properties
Human teeth have a unique structure composed of the anisotropic parts: enamel, dento-
enamel junction, dentine, cementum, cemento-enamel junction and pulp. As far as dental
wear is concerned, only the outer part of enamel and the dentinal part adjacent to enamel
have to be taken into account. Dental enamel consists of about 94% inorganic substance,
mainly hydroxyapatite and fluorapatite, 2% organic material and 4% water by weight [7].
The high hardness of enamel is attributed to its high mineral content, while its brittleness is
attributed to its low tensile strength. The mechanical properties vary with the location on
the tooth, local prism orientation and chemical composition [8,9]. Enamel is comprised of
long, thin rods arranged in parallel arrays, 2 to 3 µm in diameter, which form a complex
and complicated three-dimensional pattern [10]. The organic components of enamel are
composed of short peptide fragments, which are breakdown products of amelogenin, the
enamel matrix protein [11].
Dentine, on the other hand, is a biological compound, which consists of about 70%
inorganic material, 18% organic matrix and 12% water by weight [12]. The dentinal tubules
run through the entire dentinal substance and are surrounded by highly mineralized
dentine material. The biological interface between dentine and enamel exhibits a high
fracture toughness, thus making it possible to dissipate stresses and prevent crack
propagation [9]. The underlying more resilient dentine supports the integrity of the enamel.
Dentine demonstrates a considerably higher fracture toughness than the overlaying
enamel, which is much harder than dentine. The physical and mechanical properties
(mean values) of enamel and dentine are listed in Table 1. The values should only be
regarded as rough guidelines, as the table is compiled from different studies and textbooks
and the study design of the experiments that provided the data might have differed from
one study to the other. The table also contains data (mean values) on contemporary
composite resin materials. It can be seen that the physical properties of composite resins
match very well those of enamel or dentine, except for fracture toughness and Young`s
modulus, which is much higher in dentine and enamel respectively. However, there are
differences with regard to the composition of composites. Microfilled composites have a
low friction, but also a low modulus of elasticity and fracture toughness. By contrast, hybrid
composites exhibit a higher friction but also a higher fracture toughness.
15
Enamel Dentine Composites
Hardness (GPa) (microhardness indentation)
3.03 a 0.58 a 0.5-0.6 b
Flexural strength (MPa) 141 c 172 d 90-170 e Compressive strength (MPa) 384 f 297 f 250-400 f
Tensile strength (MPa) 10 f 52 f 40-90 f Fracture toughness (MPa m1/2) 0.77 a 3.4 g 0.6-1.4 h
Young`s modulus (GPa) 94 a 20 a 3-20 f Coefficient of thermal expansion
(µm/m°K) 11.4 i 8.3 i 14-50 i
Density (g/cm-3) 2.97 i 2.14 i 1.6-2.4 i Thermal conductivity (W m-1 K-1) 0.93 i 0.57 i 1.09-1.37 i
Friction coefficient µ 0.14 k 0.31 k 0.1-0.6 l Table 1: Physical parameters (mean values) of enamel and dentine in comparison to composite. The letters refer to the literature: a [9], testing occlusal enamel; b [13], c [14], d [15], e [16], f [17]; g [18], h [19], i [20] for bovine enamel-dentine complex; k [21], l [22].
Tribology in the oral cavity: factors and processes
Dental hard tissues (enamel, dentine) are subject to wear the very moment when they
erupt into the oral cavity or when they get into contact with the antagonist tooth. The same
holds true for a dental restoration, which is subject to wear processes from the first
moment it is inserted into the oral cavity. Different wear mechanisms can be distinguished
and they refer to both enamel and artificial restorative materials. In the case of intracoronal
restorations, such as direct fillings or inlays, both artificial and biological substrates are
subject to wear in the same tooth. When teeth get into contact without a food bolus or
anything in between them, this is called two-body or attrition wear (from Latin attritio =
rubbing against) [23]. When we chew on food items or brush our teeth with a toothbrush
and toothpaste, three-body or abrasive wear (from Latin abrasio = wear or abradere = to
scratch off) is caused. Buccal and lingual tooth surfaces are mainly exposed to mechanical
oral hygiene procedures causing abrasive wear, while the occlusal surfaces are subject to
both attrition and abrasive wear, which occur almost simultaneously or in short subsequent
episodes. Another phenomenon is described as adhesion wear (from Latin adhaesio =
adherence) and occurs when two solid surfaces slide over one another under pressure.
Surface projections or asperities are plastically deformed and eventually joined together by
the high local pressure. In the process, material may be transferred from the artificial
material on one tooth to the artificial material on the opposing tooth or to the tooth enamel.
Likewise, a similar transfer of material may happen on the proximal surfaces of
16
neighbouring or adjacent teeth. Fatigue wear occurs when large portions of dental hard
tissues or restorative material chip off. If this occurs on the cervical part of the tooth, the
term “abfraction” is used.
All these mechanical interactions between two materials, which result in a net loss of
material (fatique wear/abfraction) can be further described by friction that leads to
microploughing, microcutting, microcracking, and microfatigue [24].
Another essential influencing factor in the oral cavity is saliva, which functions as a
lubricant and diminishes wear by reducing the friction. Saliva is produced by three
glandulae, namely the Glandula parotis, the Glandula submanidbularis and the Glandulae
linguales. Saliva contains mainly water and only 0.5% dissolved substances.
Mucopolysaccharides and glycoproteins mainly act as the lubricant in saliva. All solid
tissues and mucosal membranes in the oral cavity are covered by a layer of absorbed
salivary proteins, the so-called acquired pellicle, which forms instantly after e.g. cleaning
procedures. Saliva is also essential to prepare food to swallow it. Besides the lubricant
function, saliva contains buffer systems that neutralize both acids from the food bolus and
products from bacterial activities. In addition to the mechanical interactions, chemically
active substances can also attack dental hard tissues and restorative materials. When
acidic substances interact with high occlusal loads, the wear rate may be dramatically
accelerated, as an in vitro study has shown [25]. These substances can derive from acidic
food items, like soft drinks, fruit, juices, vinegar, etc, from the gastric reflux, like in the case
of patients suffering from bulimia or anorexia nervosa, or from sources outside the oral
cavity, like factories that emit acidic substances in the air [26]. The acidic attacks that
cause loss of tooth substance are summarized as erosive wear (from Latin erodere =
“gnawing off”), although the term corrosive wear (from Latin corrodere = “gnawing away”)
would be more adequate [27]. In a report of a workshop on the mechanisms,
manifestations and measurements of wear, only the following four types were described:
adhesive wear, abrasive wear, fatigue wear and corrosive wear [23].
All these processes occur in the biomechanical stomatognathic system with the teeth of
the upper jaw being fixed to the skull, while the teeth of the lower jaw are movable in three
directions: to the lateral, front and vertical thus giving the jaw a high degree of movement
flexibility. The teeth get into contact during the conscious activity of chewing food items
and as a side effect during other processes, such as swallowing, speaking and yawning.
Tooth contacts other than these are attributed to parafunctional or pathological actions or
habits, namely bruxism and thegosis [28]. Bruxism is the technical term for teeth grinding
without food and occurs mainly unconsciously and predominantly at night during short
17
periods of 30 to 60 seconds each hour [29]. Patients suffering from bruxism exert high
biting forces during the gnashing phases [30]. Maximal biting forces, however, do not
seem to be different compared to non-bruxers [31]. In some patients, bruxism leads to the
hypertrophy of masticatory muscles (eg M. masseter) and to a considerable wear of the
teeth, even to the point where dentine becomes exposed. Equally, restorative materials
show more wear, fracture or chipping in bruxers. The number of people that show some
level of bruxism has significantly increased over the last three decades [32]. Based on
several cross-sectional studies, estimates assume that the prevalence of bruxism in the
industrialized countries is in the range of 20% with physiological stress factors being the
most important etiological factor [33]. Thegosis is the process of sliding teeth into a lateral
position that may derive from the evolutionary genetic habit to sharpen teeth. Other actions
that cause friction and wear on teeth are pipe-smoking as well as the chewing on pencils,
tooth picks, finger nails etc.
The biomechanical process of mastication is very complex and is regulated by trigger
zones in the brain stem and submitted to multiple feedback mechanisms, some of them
are located in the periodontal ligament [34]. Mastication reduces the food bolus to a few
square millimetres, which facilitates swallowing and digestion. Typically, the masticatory
cycle can be divided into four phases [35,36] (Figure 2). First the lower jaw is opened and
slides into a lateral position to get into contact with the food bolus. The second phase
starts when the teeth get into contact with the food bolus, the anterior teeth bite off a piece
of the food and push it to the posterior region. During this phase, biting loads are applied
and distributed through the food bolus which gets entrapped between the occluding teeth.
In the third phase, the food is compressed and ground while the teeth move laterally and in
the fourth phase the teeth move back to their original position. The entire masticatory
movement is further complicated because it is completed in two planes: the horizontal
(lateral) and frontal planes [37]. In the horizontal plane, the movement line is an arc formed
by rotation around the working condylus of the temporo-mandibular joint. When the
working condylus is moving to a lateral position, the teeth on the balancing side lose
contact in most patients.
The profile of the force curve corresponds to the positive half of a sine curve and is
therefore also called haversine wave form [37]. The masticatory force depends on the
texture of the food as well as on the location within the oral cavity. Higher forces are
exerted in the posterior region and when grinding hard food. However, the biting force
varies substantially between different individuals. Lower biting forces were detected in
women compared to men as the latter have larger masticatory muscles. Furthermore, the
18
biting force decreases with age, with young adults having the highest forces. The
magnitude of biting force is in the range of 10 to 20 N in the initial biting phase and in the
range of 100 to 140 N in the molars and 25 to 45 N in the incisor teeth at the end of the
chewing cycle [38]. The entire cycle lasts for about 0.8 seconds whilst the mean duration
of occlusion is only about 0.4 to 0.6 seconds [34,38]. The sliding distance is less than 1
mm with a speed of 0.25 to 0.5 mm/sec [39].
The tooth contact periods add up to 15 to 30 minutes per day, depending on the eating
frequencies and habits, not including the tooth contact during swallowing, which, however,
is only of a lower magnitude. If a mean chewing frequency of about 1.5 Hz and a chewing
time of about 20 minutes per day are assumed, an individual carries out 4.87 million
chewing cycles per year. According to estimates, human beings chew 18 tons of food on
average during their lifetime.
How to measure clinical wear
In 1984 Smith and Knight published a Tooth Wear Index (TWI) to assess the clinical wear
of human enamel [40]. The index, which comprises 4 scores, was designed to record
levels of tooth wear regardless of the etiology. Each visible tooth surface (buccal, lingual,
occlusal/incsial) is recorded together with a separate score for the buccal cervical area,
which sometimes has a different wear pattern.
In the early seventies, a scoring system was developed to assess the clinical performance
of restorative materials, known as the United States Public Health Services (USPHS)
criteria [41]. The reason for developing this system was to provide a more or less
standardizable and structured tool to evaluate and compare the clinical work of general
practitioners and collect data for insurance companies. Later on, the system started to be
applied to new materials so that they could be compared with clinically proven materials,
such as amalgam or ceramic inlays [42]. Among many other criteria, wear of material is
evaluated as part of the USPHS scoring system. The evaluation, however, is very
subjective and the wear cannot be accurately assessed [43]. As research workers
recognized the shortcomings of this scoring system, they modified the criteria according to
their needs, which led to many different modified USPHS criteria. Only recently, a group of
renowned scientists have further developed the USPHS criteria by systematically
structuring them based on evidence and normative and subjective guidelines,
acknowledging, however, that wear can only be quantified by sophisticated equipment
[44].
19
In the eighties, a method which related the loss of material at the restoration margins to
the overall wear of the material was developed. For this purpose, impressions of the teeth
were taken and the cast models were compared to a set of standards derived from clinical
restorations, such as the Leinfelder scale with 6 standards [45] or the Moffa-Lugassy scale
(M-L scale), which is based on dies with cylindrical defects and includes 18 standards [46].
The latter was modified by V. Rheinberger using tooth-sized dies with restoration-like
incremental defects known as the Vivadent scale [47]. However, it has been proven that
the actual wear is systematically underestimated when those scales are used [48].
With the development of mechanical and electro-optical sensors, which are used in
industrial manufacturing for different applications (topography, roughness, material loss,
etc), these systems or principles became also available for the quantification of clinical
wear. However, it is necessary to take impressions as a system that measures wear
directly in the oral cavity is not available to date. The quality of the impression is therefore
crucial for accurate measurements. Optical systems that use optical technology have
advantages over mechanical sensors. Especially one system has been identified so far to
measure wear with an accuracy of 10 µm [49]. Impressions should be taken for each
restored tooth under investigation, using a light-body polyvinylsiloxane material in a
conventional partial tray after thorough cleaning of the teeth with pumice and a rotating
brush. The author’s own experience has shown that it is advisable to make a second
impression and discard the first one, as plaque remnants that were not removed by the
tooth cleaning procedure tend to be removed by the first impression. A recent comparative
analysis of accuracy of clinical wear measurement using replica models revealed no
difference between individually fitted and conventional trays [50].
Clinical importance of wear of teeth and dental materials
Wear of natural teeth can have mainly two consequences: (1) aesthetical effects that
compromise the appearance of a restoration; (2) functional effects that alter the
relationship between the tooth and antagonist(s) and/or tooth and adjacent tooth by
promoting phenomena like elongation of antagonists, movement of teeth or reduction of
vertical height with consequences to the TMJ. For artificial materials, another side effect of
material wear becomes apparent: swallowed or inhaled worn particles may have
biological/toxicological effects. Little is known about the systemic effects of material
components, such as clearance of the worn material, adverse effects, chemical reactions
or a possible incorporation of worn material into body cells or tissues.
20
With composites, there is a certain amount of concern that, besides the leaching of
monomer components, micro- and nano-sized inorganic filler particles of composite resins
that are worn, swallowed or inhaled and accumulated into tissues could be linked to
diseases of the liver, kidney and intestine [51,52]. There is, however, no scientific evidence
to date that the absorbed particles pose a health risk to the patient. In vivo measurements
of 31 composite fillings (14 premolars, 17 molars; Tetric EvoCeram) revealed a mean
volume loss in premolars of 0.25 mm3 and in molars of 0.75 mm3 after 2 years of clinical
service with a maximum of 0.4 mm3 in premolars and 1.0 mm3 in molars (Figure 2 A) [53].
The increase of material loss of composite resin materials is not linear, although long-term
measurements in vivo are missing. The material loss per mm2 was calculated to be 0.01
mm3 for premolars and 0.02 mm3 for molars (Figure 2 B).
premolar molar
0.0
0.2
0.4
0.6
0.8
1.0
1.2
95
% C
I (
mm
E3)
6 months12 months24 months
premolar molar
0.005
0.010
0.015
0.020
0.025
0.030
95%
CI
(mm
E3
/mm
E2
)
6 months12 months24 months
A B Figure 2: (A) Volumetric wear in vivo (mm3) and (B) volumetric wear in relation to surface area in vivo (mm3/mm2) of a fine-hybrid composite material in relation to tooth type and time. If all posterior teeth were restored with medium-sized composite fillings, the maximum total
material loss would be about 11 mm3 within two years of clinical service, based on the
data of the above-mentioned clinical study. However, other composite materials may wear
more quickly (or to a larger extent) and the wear of crowns and bridges made of composite
material is generally larger than that of intracoronal restorations [54,55].
As far as the biological consequences on the stomatognathic system are concerned, there
is little evidence that occlusal wear as such leads to the dysfunction of the TMJ, to muscle
pain or periodontal disease [56-61]. Even severe loss of occlusal tooth substance due to
wear is compatible with good oral health, as the stomatognathic system is highly adaptive
21 premolar molar
0
50
100
150
200
µm
6 months12 months24 months
to changes. Even the loss of posterior support does not increase the wear of anterior teeth
[62].
However, if the loss of material becomes clinically visible, the wear affects the aesthetic
appearance of the restoration, especially in the anterior region. Excessive wear may lead
to premature failure and replacement of the restoration. According to a clinical study on
1007 individuals in southeast England, the percentage of excessive wear on natural teeth
varied between 3% and 9% of tooth surfaces according to the different age groups [62].
Based on the evidence available, it may be concluded that wear as such is an aesthetical
problem in the first place, which may, however, lead to the premature failure and
replacement of a restoration. Aesthetical effects of material loss are obviously depending
on the severity and location of the restoration.
Wear behaviour of natural teeth
Dental enamel is highly resistant to wear with an annual wear rate of about 30 to 40 µm
[53,63], although the wear seems not to increase on a linear basis and is independent of
the tooth type (Figure 3). The excellent wear resistance of dental enamel is mainly
attributed to the intricate crystallite orientation of the enamel prisms, which give the enamel
unparalleled hardness. Only diamond burs with high speed are able to cut enamel. The
wear of enamel is mainly resulting from microfracture processes and characterized by
delamination and microploughing. In contrast the wear of dentine is determined by ductile
chip formation. The wear rate of enamel is higher during the first two years after coming
into contact with the opposing teeth (running-in phase) and decreases thereafter (steady-
state phase). A similar pattern can be observed with restorative materials. However, the
surface hardness of enamel and its wear depth varies with age: lower hardness and higher
wear depths were observed in patients belonging to older age groups compared with
patients belonging to young age or middle aged groups.
Figure 3: Box plot of enamel loss in vivo of 34 teeth with intracoronal restorations. Data from [53].
22
Wear behaviour of composite resins
The various artificial dental materials can be grouped into five different categories: metal
alloys, ceramics, amalgams, composites and unfilled polymers. Of all these materials, the
composite resins show a particular wear pattern, because many characteristics, which are
associated with their composition, directly influence their wear resistance. Composites
consist of filler particles dispersed in a brittle polymer. The fillers consist of glass particles
such as silicon oxide (quartz), barium aluminium silicate or fillers that are manufactured
from the matrix polymer by grinding the matrix to small sizes, so-called pre-polymer fillers.
The polymers are produced from different monomers, such as bisphenol-glycidyl
methacrylate (BIS-GMA), urethane dimethacrylate (UDMA), triethylene glycol
dimethacrylate (TEGDMA) and other monomers, which are polymerized with initiators that
are sensitive to halogen light [64]. Optimally, the loading force is completely transferred
from the matrix to the filler particles. The size, shape and hardness of the fillers, the quality
of the bonding between fillers and polymer matrix, the polymerization dynamics of the
polymer all have an effect on the wear characteristics of a dental material. The various
components of the composition, on the other hand, influence the physical properties of the
composite, such as flexural strength, fracture toughness, Vickers hardness, modulus of
elasticity, curing depth, etc. These properties, in turn, may influence the wear of the
composite. In direct contact between composite resin and antagonist, the wear pattern is
mostly a combination of attrition/abrasive wear and microfatigue (see Figure 5d). The
friction coefficient and the surface roughness are determining factors for the wear rate of
composites. Thus, the size and volume of the fillers affect the wear rate. A low elastic
modulus leads to higher contact areas and consequently to lower pressures. Large filler
particles, on the other hand, are combined with high friction coefficients and lead to high
internal shear stress in the polymer matrix. The latter in particular occurred in the early
composites of the eighties, which contained large fillers and showed excessive wear in the
posterior region. This was clinically visible as loss of contour. The composites had been
continuously optimized since then and the composites of the late nineties did not show this
excessive wear any more [65] but their wear rate was still larger than that of enamel.
Nowadays, wear is more likely to occur at occlusal contact areas (OCA) than on contact-
free areas (CFA). In a clinical trial on 31 posterior resin restorations, the median vertical
loss after 2 years was 143 µm for molars and 114 µm for premolars [53]; the difference
was, however, statistically significant only for the 1-year recall (Figure 4). Yet, the
variability was very high and the distribution was uneven amongst the individuals of the
23
premolar molar
0
100
200
300
400 6 months12 months24 months
test group: about 60% of total wear was limited to 30% of restorations. Even the
measurable high amount of material loss at localized sites of a restoration is generally not
visible by clinical inspection (Figures 5a-5d).
Figure 4: Box plot graph of the maximal vertical loss (µm) of a nanofilled composite resin in relation to tooth type and time (data of a clinical study [53]).
According to prospective clinical trials, which evaluated modern composite resins,
composite fillings fail and have to be replaced not due to wear but due to secondary
caries, marginal and/or bulk staining and fractures [66,67]. Even a clinical trial over a
period of 20 years involving three composite resins demonstrated that wear was not the
primary cause of failure [68].
24
a b
c d Figure 5: A composite resin restoration at baseline (a) and at the 24-month recall (b) with markings of the occlusal stops. (c) Differential picture of the same restoration: wear quantification: the redder the area, the higher is the material loss; the wear in the red occlusal areas is between 100 and 150 µm. (d) SEM picture (x154) of the same restoration: wear facet caused by attrition (see arrow) as in Figure 5b after 24 months in situ. (Clinical pictures by Arnd Peschke) Laboratory methods to test dental materials for wear
Dental research has become especially aware of the problem of wear of dental materials
in the nineteen eighties when the first studies with posterior composite resins showed a
large amount of wear within a short period of time. For decades, posterior teeth were
25
mainly restored with amalgam and gold alloys and later on with ceramic materials and the
clinical experience was that these materials did not exhibit much wear over time. It was
also in the nineteen eighties, when people thought of methods to predict wear through
laboratory tests. The first wear testing methods were developed.
The first reliable test on frictional wear was carried out by Charles Hatchett (1760-1820),
who used a simple reciprocating machine to evaluate the wear on gold coins. He found
that compared with self-mated coins, coins with grits between them wore at a faster rate.
In industrial engineering, the wear resistance of artificial materials is typically evaluated
with pin-on-disc machines and the wear resistance of varnishes and other covering
materials is assessed by scratch tests. Norms established by the ATMS are used.
In 2001, the International Organization for Standardization ISO published a technical
specification on “Guidance on testing of wear”, describing 8 different test methods of two-
and/or three-body contact [69] (Table 2).
Method Stylus Medium Movement Force Number of cycles
Reference material
DIN Al2O3 water sliding 8-10 MPa ? PMMA
ACTA steel millet sliding 15 N 200,000 - Zurich enamel water
+alcohol +toothbrushing
impact (+sliding)
49 N 1,200,000 last test
Alabama poly-acetal PMMA beads impact+ sliding
75 N 400,000 -
Freiburg Al2O3 water sliding 8 MPa 40,000 PMMA
Minnesota tooth water sliding 13.35 N 500,000 - OHSU enamel poppy seeds/
PMMA beads impact
+sliding 20/70 N 50,000 -
Newcastle steatite water sliding 15 N 10,000 - Table 2: Two-/three-body wear methods listed in the ISO Technical Specification No 14569-2 [69]. The different test methods vary with regard to load, number of cycles and their frequency,
abrasive medium, type of force actuator, sliding movement, etc. However, an assessment
of the different wear methods was not performed. Furthermore, many of these tests fail to
define a qualification protocol for the test equipment or a validation procedure for the test
method, which is run in conjunction with the equipment. Both qualification and validation,
however, are indispensable prerequisites for a test to become a standard laboratory test
[70]. Therefore, the reproducibility of test results is a prerequisite for a test method to fulfil
the criteria of a validated test method. Otherwise, it is always necessary to repeat wear
tests with a reference or standard material, which is time-consuming and reduces the
26
significance and validity of the test method. At present, only two chewing simulators which
use two axes of movement (vertical and horizontal) and whose force is regulated are
commercially available: the MTS chewing simulator [37,71] and the Bose ElectroForce
3330 Dental Wear Simulator (www.bose-electroforce.com). However, some institutes
developed their own systems such as the OHSU machine [72], the Alabama machine [73],
the Zurich machine [74], the Regensburg simulator [75] and the BIOMAT simulator [76].
More recently, a complex system with six actuators has been developed at the University
of Bristol: the Dento-Munch Robo-Simulator [77]. This simulator tries to mimic the entire
process of movements of the lower jaw by using a Stewart platform. As all simulators
follow different approaches because they are based on different operational concepts, the
results cannot be compared, even if an effort is made to use the same wear parameters. A
device that is used to test dental materials for wear should have the following features:
Force and force impulses should be reproducible and adjustable in the range of 20 N to
150 N. Preferably, calibration should not be necessary for the testing of each material.
- A lateral movement of the stylus should be integrated in the system to be able to
test the material for microfatigue.
- Constant water exchange should also be integrated to remove abraded particles
from the interface between stylus and material.
- All movements should be computer-controlled and adjustable.
One of the best compromises in terms of cost and efficiency is the two-axis chewing
simulator Willytec or “Munich” simulator [78]. This chewing simulator operates with dead
weights that are put on vertical bars, which are descended with stepping motors. The
weight can be varied between 1 and 11 kg. Additionally, a lateral movement, which is also
driven by a stepping motor, can be integrated into the wear method. Both the vertical and
horizontal axes are computer-controlled. The chewing simulator includes eight chambers
so that eight specimens can be tested at the same time. Simultaneous flooding and
evacuation of each chamber with water of different temperatures (thermocycling) is
integrated into the system. The Willytec chewing simulator can be used for different
purposes: wear testing, loading of prosthodontic reconstructions like crowns, bridges,
implant systems or fillings, which are placed in extracted teeth. Early in 2008, a
questionnaire was sent to all dental universities and dental companies which use the
Willytec simulator. Currently, 22 simulators are in operation: 18 at dental universities and 4
at dental companies. A simulator, which was used in the USA (New Orleans), was
destroyed during the 2005 flooding. Two of the 22 simulators use pneumatic actuators to
lift the weights from the specimen to be tested. Three dental universities have 2 or even 3
27
simulators and 1 dental company has two. Seventeen of them are located in Germany and
5 in other countries. In spite of having sent them two reminders, only eleven dental
universities with 15 simulators and two dental companies with 3 simulators have
responded to the questionnaire. The results of the questionnaire are presented in Figure 6.
Most research institutes (11 out of 13) use the simulator for wear tests and many use it
also for other purposes, such as loading of crowns and bridges or implants.
%
0
20
40
60
80
100
wear loading of
crowns
loading of
implants
loading of
fillings
loading of
posts
others
Figure 6: Research areas (in percentage of respondents) with regard to the use of the Willytec chewing simulator (multiple answers were possible). Data of an unpublished survey.
The following wear influencing factors should be taken into consideration:
Surface roughness of specimen: The surface roughness of the specimens prior to carrying
out the wear generating processes may have an influence on the wear rate of composite
materials.
Number of specimens: The scattering of the results expressed by the standard deviation
rate determines the number of specimens required to statistically differentiate between
materials. The variability of the test results mainly reflects the quality of the wear testing
device. The more robust a device is constructed and the more reproducible test
parameters such as force, speed of stylus, etc. can be maintained, the lower is the
variability.
Storage of specimens prior to testing
Loading force: It may be assumed that higher forces produce more wear. However, the
relationship does not seem to be linear. There might be even a certain cut-off point at
28
which an increase in the loading force does no longer result in an increase in wear. To
date, this has been verified with two composite resin materials (Figure 6).
Figure 6: Wear of two composite materials in relation to load (2kg/5kg/10kg). HM = Heliomolar (microfilled composite), TC = Tetric Ceram (fine-particle hybrid)
Size and shape of stylus: From theoretical considerations it can be assumed that a sharp
stylus produces more wear than a sphere-shaped stylus, because the contact area
between stylus and material is larger in the latter and hence produces less fatigue stress
on the material.
Sliding of stylus: Sliding is an essential component of a wear testing method because a
material is subjected to microfatigue.
Descent/lifting speed of stylus: The speed with which the stylus hits the surface of the
specimen creates a force impulse, which is different with varying speeds. If weights are
used to exert a force, then the force that is generated on the material is the product of the
weight and the descent speed (F=m x a, N). Furthermore, the time during which the force
is exerted is another variable, i.e. the force impulse is the product of the force and the time
the force is applied (F = F x t, Ns).
Lubricant: Lubricants, such as artificial saliva, reduce the wear as they lower the friction
coefficient. A constant change of water removes the worn particles from the interaction
zone between stylus and material, thus reducing the effect of the worn material, which,
otherwise, may act as an abrasive medium.
Number of cycles: The wear increases with increasing number of cycles. Most in vitro wear
test methods demonstrate a run-in phase with a steep increase in wear in the initial phase
and a flattening of the curve thereafter (Figure 7).
29
0
5
10
15
20
25
30
ACTA Alabama Ivoclar Munich Zurich
0
10
20
30
40
50
60
70
cycles (%)
wear (%)
Figure 7: Percentage of cycles (left axis) in relation to the percentage of mean final wear (right axis) of ten materials. An example in conjunction with the Ivoclar method: after 8.3% of the total number of cycles 41 % of the final wear has already occurred. Unpublished data of Round Robin test for ACTA, Ivoclar, Munich, Zurich and Alabama in conjunction with 4 materials: [79,80].
Abrasive medium: An abrasive medium can decrease or increase the wear depending on
whether it is used in dry or wet conditions.
Another decisive question is whether or not the simulation method correlates with clinical
wear. In a workshop report on wear (mechanisms, manifestations and measurement), it
was stated that laboratory simulation methods are useful to study fundamental wear
mechanisms but they are not able to predict clinical wear [23]. It should be, however, the
goal of any laboratory method to at least roughly assess the clinical wear properties of a
dental restorative material prior to the insertion into the oral cavity. This is especially useful
for dental companies which develop many different variants of the same material (concept)
or which are pursuing completely new and innovative material technologies. Therefore, the
wear resistance of dental materials should be evaluated in the laboratory by reliable wear
testing methods before the materials are tested in clinical trials.
30
References
[1] Hunter J (1778). The Natural History of Human teeth. Explaining their Structure, Use, Formation, Growth and Diseases. London: J Johnson, pp. 98-100.
[2] Jost HP. Lubrication (tribology) education and research. Department of Education and Science,
HMSO, 1966. [3] Petersen MB, Winer WO. Wear Control Handbook. New York: The American Society of
Mechanical Engineers, 1980. [4] DIN. Verschleiss - Begriffe, Systemanalyse von Verschleissvorgängen, Gliederung des
Verschleissgebietes (DIN 50320). Berlin: Beuth, 1979. [5] Burwell JT. Wear 1959;1:119. [6] Czichos H (1986). Introduction to friction and wear. In: Friction and wear of polymer composites.
K Friedrich editor. Amsterdam: Elsevier, pp. 1-22. [7] Gwinnett AJ. Structure and composition of enamel. Oper Dent (Suppl 5) 1992;17:10-7. [8] Habelitz S, Marshall SJ, Marshall GW, Jr., Balooch M. Mechanical properties of human dental
enamel on the nanometre scale. Arch Oral Biol 2001;46:173-83. [9] Xu HH, Smith DT, Jahanmir S, Romberg E, Kelly JR, Thompson VP, Rekow ED. Indentation
damage and mechanical properties of human enamel and dentin. J Dent Res 1998;77:472-80.
[10] Ten Cate AR. Oral histology: development, structure, and function. St. Louis: Mosby, 1994. [11] Yamakoshi Y, Hu JC, Zhang H, Iwata T, Yamakoshi F, Simmer JP. Proteomic analysis of
enamel matrix using a two-dimensional protein fractionation system. Eur J Oral Sci 2006;114:266-71; discussion 285-6, 382.
[12] Marshall GW, Jr. Dentin: microstructure and characterization. Quintessence Int 1993;24:606-
17. [13] Knobloch LA, Kerby RE, Clelland N, Lee J. Hardness and degree of conversion of posterior
packable composites. Oper Dent 2004;29:642-9. [14] Ghavamnasiri M, Abedini S, Mehdizadeh Tazangi A. Effect of different time periods of vital
bleaching on flexural strength of the bovine enamel and dentin complex. J Contemp Dent Pract 2007;8:21-8.
[15] Hayashi M, Koychev EV, Okamura K, Sugeta A, Hongo C, Okuyama K, Ebisu S. Heat
treatment strengthens human dentin. J Dent Res 2008;87:762-6. [16] Adabo GL, dos Santos Cruz CA, Fonseca RG, Vaz LG. The volumetric fraction of inorganic
particles and the flexural strength of composites for posterior teeth. J Dent 2003;31:353-9. [17] Rawls HR, Esquivel-Upshaw JF (2003). Restorative resins. In: Phillip`s Science of Dental
Materials. KJ Anusavice editor. St. Louis: Saunders, pp. 399-441. [18] Yan J, Taskonak B, Platt JA, Mecholsky JJ, Jr. Evaluation of fracture toughness of human
dentin using elastic-plastic fracture mechanics. J Biomech 2008;41:1253-9.
31
[19] Watanabe H, Khera SC, Vargas MA, Qian F. Fracture toughness comparison of six resin composites. Dent Mater 2008; 24:418-25.
[20] Anusavice KJ, Brantley WA (2003). Physical properties of dental materials. In: Phillip`s
Science of Dental Materials. KJ Anusavice editor. St. Louis: Saunders, pp. 42-71. [21] Habelitz S, Marshall SJ, Marshall GW, Jr., Balooch M. The functional width of the dentino-
enamel junction determined by AFM-based nanoscratching. J Struct Biol 2001;135:294-301.
[22] Wassell RW, McCabe JF, Walls AW. A two-body frictional wear test. J Dent Res
1994;73:1546-53. [23] Mair LH, Stolarski TA, Vowles RW, Lloyd CH. Wear: mechanisms, manifestations and
measurement. Report of a workshop. J Dent 1996; 24:141-8. [24] Suh NP. Tribophysics. New Jersey: Prentice-Hall, 1986. [25] Kaidonis JA, Richards LC, Townsend GC, Tansley GD. Wear of human enamel: a
quantitative in vitro assessment. J Dent Res 1998;77: 1983-90. [26] Lussi A, Jaeggi T. Erosion--diagnosis and risk factors. Clin Oral Investig 2008;12:S5-13. [27] Zhou ZR, Zheng J. Tribology of dental materials: a review. J Phys D Appl Phys 2008; [28] Attanasio R. An overview of bruxism and its management. Dent Clin North Am 1997;41:229-
41. [29] Baba K, Clark GT, Watanabe T, Ohyama T. Bruxism force detection by a piezoelectric film-
based recording device in sleeping humans. J Orofac Pain 2003;17:58-64. [30] Nishigawa K, Bando E, Nakano M. Quantitative study of bite force during sleep associated
bruxism. J Oral Rehabil 2001;28:485-91. [31] Cosme DC, Baldisserotto SM, Canabarro Sde A, Shinkai RS. Bruxism and voluntary maximal
bite force in young dentate adults. Int J Prosthodont 2005;18:328-32. [32] Granada S, Hicks RA. Changes in self-reported incidence of nocturnal bruxism in college
students: 1966-2002. Percept Mot Skills 2003;97:777-8. [33] Kuliš A, Türp JC. Bruxismus - gesicherte und potenzielle Risikofaktoren. Schweiz Monatsschr
Zahnmed 2008;118:100-7. [34] Schindler HJ, Stengel E, Spiess WE. Feedback control during mastication of solid food
textures--a clinical-experimental study. J Prosthet Dent 1998;80:330-6. [35] Bates JF, Stafford GD, Harrison A. Masticatory function--a review of the literature. 1. The form
of the masticatory cycle. J Oral Rehabil 1975;2:281-301. [36] Bates JF, Stafford GD, Harrison A. Masticatory function - a review of the literature. III.
Masticatory performance and efficiency. J Oral Rehabil 1976;3:57-67. [37] DeLong R, Douglas WH. Development of an artificial oral environment for the testing of dental
restoratives: bi-axial force and movement control. J Dent Res 1983;62:32-6.
32
[38] Kohyama K, Hatakeyama E, Sasaki T, Dan H, Azuma T, Karita K. Effects of sample hardness on human chewing force: a model study using silicone rubber. Arch Oral Biol 2004;49:805-16.
[39] Gibbs CH, Lundeen HC, Mahan PE, Fujimoto J. Chewing movements in relation to border
movements at the first molar. J Prosthet Dent 1981;46:308-22. [40] Smith BGN, Knight JK. An index for measuring tooth wear. Br Dent J 1984;156:435-438. [41] Cvar JF, Ryge G (1971). Criteria for the clinical evaluation of dental restorative materials. In:
US Public Health Service. San Francisco: US, Government Printing Office, pp. 244. [42] Ryge G (1989). The California Dental Association quality evaluation system: A standard for
self-assessment. In: Quality evaluation of dental restorations. A K. editor. Chicago: Quintessence Inc., pp. 273-286.
[43] Taylor DF, Bayne SC, Sturdevant JR, Wilder AD. Comparison of direct and indirect methods
for analyzing wear of posterior composite restorations. Dent Mater 1989;5:157-60. [44] Hickel R, Roulet JF, Bayne S, Heintze SD, Mjör IA, Peters M, Rousson V, Randall R, Schmalz
G, Tyas M, Vanherle G. Recommendations for conducting controlled clinical studies of dental restorative materials (Science Committee Project 2/98 - FDI World Dental Federation). J Adhes Dent 2007;9 (Supplement 1):121-147.
[45] Leinfelder KF, Taylor DF, Barkmeier WW, Goldberg AJ. Quantitative wear measurement of
posterior composite resins. Dent Mater 1986;2:198-201. [46] Moffa JP, Lugassy AA. Calibration of evaluators utilizing the M-L occlusal loss scale. J Dent
Res 1986;65:302, Abstract No. 1197. [47] Bryant RW. Comparison of three standards for quantifying occlusal loss of composite
restorations. Dent Mater 1990;6:60-2. [48] Perry R, Kugel G, Kunzelmann KH, Flessa HP, Estafan D. Composite restoration wear
analysis: conventional methods vs. three-dimensional laser digitizer. J Am Dent Assoc 2000;131:1472-7.
[49] Mehl A, Gloger W, Kunzelmann KH, Hickel R. A new optical 3-D device for the detection of
wear. J Dent Res 1997;76:1799-807. [50] Peschke A, Heintze SD, Roulet JF. Comparison of two impression methods for clinical wear
measurement. J Dent Res (Spec Iss B) 2005;84:Abstract No 350 (Continental European and Scandinavian Divisions) (www.dentalresearch.org).
[51] Gatti AM. Biocompatibility of micro- and nano-particles in the colon. Part II. Biomaterials
2004;25:385-92. [52] Gatti AM, Rivasi F. Biocompatibility of micro- and nanoparticles. Part I: in liver and kidney.
Biomaterials 2002;23:2381-7. [53] Peschke A, Heintze SD, Roulet JF. Two-year clinical evaluation and wear analysis of
posterior composite restorations. J Dent Res 2007;86 (Spec Issue A):Abstract No. 230 (www.dentalresearch.org).
[54] CRA. Restorative resins: Current generation Class 2 resin status report #3 - 2-year clinical
performance. CRA Newsletter 1996;20:1-3.
33
[55] CRA. Posterior full crowns 2001, Part 2: Resin crowns, 4 year clinical status. CRA Newsletter 2001;25:1-3.
[56] Genco RJ. Current view of risk factors for periodontal diseases. J Periodontol 1996;67:1041-9. [57] Carlsson GE, Egermark I, Magnusson T. Predictors of signs and symptoms of
temporomandibular disorders: a 20-year follow-up study from childhood to adulthood. Acta Odontol Scand 2002;60:180-5.
[58] John MT, Frank H, Lobbezoo F, Drangsholt M, Dette KE. No association between incisal tooth
wear and temporomandibular disorders. J Prosthet Dent 2002;87:197-203. [59] Seligman DA, Pullinger AG, Solberg WK. The prevalence of dental attrition and its association
with factors of age, gender, occlusion, and TMJ symptomatology. J Dent Res 1988;67:1323-33.
[60] Bernhardt O, Gesch D, Splieth C, Schwahn C, Mack F, Kocher T, Meyer G, John U, Kordass
B. Risk factors for high occlusal wear scores in a population-based sample: results of the Study of Health in Pomerania (SHIP). Int J Prosthodont 2004;17:333-9.
[61] Gesch D, Bernhardt O, Kirbschus A. Association of malocclusion and functional occlusion with
temporomandibular disorders (TMD) in adults: a systematic review of population-based studies. Quintessence Int 2004;35:211-21.
[62] Smith BG, Robb ND. The prevalence of toothwear in 1007 dental patients. J Oral Rehabil
1996;23:232-9. [63] Lambrechts P, Braem M, Vuylsteke-Wauters M, Vanherle G. Quantitative in vivo wear of
human enamel. J Dent Res 1989;68:1752-4. [64] Van Noort R. Introduction to Dental Materials. Edinburgh: Mosby Elsevier, 2007. [65] Sarrett DC. Clinical challenges and the relevance of materials testing for posterior composite
restorations. Dent Mater 2005;21:9-20. [66] Manhart J, Chen H, Hamm G, Hickel R. Buonocore Memorial Lecture. Review of the clinical
survival of direct and indirect restorations in posterior teeth of the permanent dentition. Oper Dent 2004;29:481-508.
[67] Brunthaler A, König F, Lucas T, Sperr W, Schedle A. Longevity of direct resin composite
restorations in posterior teeth. Clin Oral Investig 2003;7:63-70. [68] Pallesen U, Qvist V. Clinical evaluation of three posterior composite resins: 20-year report. J
Dent Res 2005;84 (Spec Issue B):Abstract 145 (www.dentalresearch.org). [69] ISO. Dental materials - Guidance on testing of wear. Part 2: Wear by two-and/or three body
contact. Technical Specification 2001;No. 14569-2. [70] FDA, Health CfDaR. Good Laboratory Practice (GLP). (PART 58 52 FR 33780, 1978, last
revision 2004) 1978; [71] DeLong R, Douglas WH. An artificial oral environment for testing dental materials. IEEE Trans
Biomed Eng 1991;38:339-45. [72] Condon JR, Ferracane JL. Evaluation of composite wear with a new multi-mode oral wear
simulator. Dent Mater 1996;12:218-26.
34
[73] Leinfelder KF, Suzuki S. In vitro wear device for determining posterior composite wear. J Am Dent Assoc 1999;130:1347-53.
[74] Krejci I, Reich T, Lutz F, Albertoni M. In- Vitro- Testverfahren zur Evaluation Dentaler
Restaurationssysteme 1. Computergesteuerter Kausimulator. Schweiz Monatsschr Zahnmed 1990;100:953-60.
[75] Rosentritt M, Leibrock A, Lang R, Behr M, Handel G. Gerät zur Simulation des Kauorgans
(Regensburger Kausimulator). Materialprüfung 1997;39:77-80. [76] Yap AU, Ong LF, Teoh SH, Hastings GW. Comparative wear ranking of dental restoratives
with the BIOMAT wear simulator. J Oral Rehabil 1999;26:228-35. [77] Alemzadeh K, Raabe D. Prototyping artificial jaws for the Bristol Dento-Munch Robo-
Simulator. 'A parallel robot to test dental components and materials'. Conf Proc IEEE Eng Med Biol Soc 2007;2007:1453-6.
[78] Kunzelmann K-H. Verschleissanalyse und -quantifizierung von Füllungsmaterialien in vivo und
in vitro. Aachen: Shaker Verlag, 1998. [79] Barkmeier WW, Latta MA, Erickson RL, Lambrechts P. Comparison of laboratory and clinical
wear rates of resin composites. Quintessence Int 2004;35:269-74. [80] Barkmeier WW, Latta MA, Erickson RL, Wilwerding TM, Simister BG. Evaluation of a
generalized wear model for composite. J Dent Res 2002;35:Abstract Nr. 3844.
35
Short description of the studies and experiments
The following six chapters describe experiments, which investigate specific questions
related to the wear of dental restorative materials, specifically the wear of resin
composites. Composite resins are nowadays the most frequently used material in dentistry
and in many countries they have replaced amalgam as the main material (material of
choice) even for restorations in the posterior region. Composite resins are also used for
indirect restorations, such as inlays/onlays as well as crowns and bridges. The studies
address topics like qualification and validation protocols for wear testing devices and
methods, wear quantification possibilities, possible substitutes for enamel as stylus
material, the relationship of physical parameters to the wear rate of contemporary resin
materials, comparison of different wear testing methods and the correlation of in vitro and
in vivo wear.
The different laboratory methods currently employed for wear testing follow different
concepts and use different devices with different process qualities. It may be argued that
current methods and systems may not be suitable for wear testing as they do not allow the
test results to be reproduced and only offer a limited range of equipment. Therefore, in the
second chapter both the principles of a qualification protocol for wear testing devices and
the validation procedure to assess wear testing methods are described. For this purpose,
the dental literature on wear was studied to find reports of laboratory tests which used
wear evaluation devices and methods. In the process, the references to specific test
methods were quantified and the reproducibility of the test results obtained with materials
that were tested more than once with the same method and parameters was evaluated.
Evidence from laboratory studies that assess the influence of different parameters on the
wear result is presented. Furthermore, the literature is reviewed with regard to known facts
of clinical wear in relation to enamel and the restorative material as well as their clinical
importance.
The use of human enamel as stylus material is related to a number of shortcomings,
including (1) non-standardization of shape and composition, which results in a large
variability of test results; (2) difficult supply because of shortage of extracted teeth; (3)
methods without lubricant, which may overestimate the wear caused by human enamel. A
few rare reports dealing with the question of the stylus material were found in the literature.
Therefore, the third chapter deals with the investigation into the wear generating effects
36
of two different ceramic materials that may serve as potential antagonist material and
substitute for human enamel as stylus material. The material as well as antagonist wear is
examined and the Ivoclar method is compared to the OHSU wear method, which includes
an abrasive medium.
To quantify the wear generated by a laboratory method, it is indispensable to have an
efficient and accurate analyzing method. However, different quantifying methods may yield
different results. In the fourth chapter, three different sensors are compared with regard
to volumetric and vertical loss of wear facets created on flat specimens: a mechanical
sensor (Perthometer), a laser sensor (Laserscan 3D) and a white light interferometry
sensor (FRT MicroProf). The wear facets are created with the Ivoclar wear method on 16
composite materials.
In the past, efforts to correlate physical parameters with wear were not truly successful.
However, if a laboratory wear method is validated and generates reproducible results, it
may be assumed that it follows defined physical parameters. It should, therefore, be
possible to create a wear formula based on physical parameters of composites. In the fifth
chapter physical parameters like modulus of elasticity, Vickers hardness, fracture
toughness, size and volume of filler particles are determined for 24 dental composite
materials (11 experimental, 13 commercially available). The 24 composite materials are
subjected to the Ivoclar method.
As different laboratory methods are used to assess the wear of dental materials, it is
essential to know how these methods correlate with each other. There is, however, no
round robin test found in the dental literature that evaluated the same dental materials with
different wear methods. Therefore, a round robin test was conducted with five different
wear methods and 10 materials. The results of this test are presented in chapter six.
Besides the Ivoclar method used at Ivoclar, the following methods (and institutes) were
included: University of Amsterdam (ACTA), Oregon Health and Science University
(OHSU), University of Zurich, and University of Munich. The specimens were made at one
spot and sent to the five test institutes. The test institutes did not know which composite
material they were testing. An amalgam and ceramic material were used as test material.
After completion of the wear generating and wear analysing processes, the wear results
were sent to the main test centre for statistical analysis.
37
Finally, a laboratory wear method must not only produce reproducible results (internal
validity) but must also proof to be clinically relevant (external validity). The wear method
should predict - to a certain degree - the clinical wear behaviour of a restorative material. A
systematic evaluation with regard to the correlation of in vitro and in vivo wear results has
not been conducted so far. Therefore, the aim of the seventh chapter was to correlate in
vivo wear data of a variety of dental materials with the most frequently used wear methods
(ACTA, Alabama, OHSU, Munich, Zurich and Ivoclar). Another issue explored in this
chapter is whether the combination of 2 or 3 laboratory methods may increase the
correlation. The in vivo data used in chapter 7 come from one source (TRAC Research
Foundation, USA), which measured the wear of many composite resins, amalgam and
enamel in human beings. Typically, about 30 large three-surface posterior restorations
were placed for each material and evaluated during a study period of up to 3 years. Wear
was measured on replicas using a light microscope focussed in the z-direction.