UNIVERSE Catalogue ed. 2019_1

UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

UNIVERSECatalogue

ed. 2019_1

Page 2: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for
Page 3: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

UNIVERSEwhere union is strength

Page 4: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

CERTIFICATIONSCertifications 1

UNIVERSE SYSTEMImplantBody 3SLsurfacetreatment 4Decontamination 5Implantneck 6Taperinternalconnection 6

SURGICAL KITCDandTDsurgicalKit 9Tools 10

SURGICAL PLANNINGSurgicalPlanning 13Preparation(Cylindricaldrillsurgicalprotocol) 14CDSurgicalProtocol 15Preparation(Tapereddrillsurgicalprotocol) 16TDSurgicalProtocol 17

PROSTHETIC PLANNINGCAD/CAMandFLEXATOR 19Impressiontaking 20Labcomponents 21Restoration 22Prostheticparts 23MUA 30

CONTENTS

PACKAGINGPackaging 37

ABOUT USAboutus 38Men,materialsandmachines 39Mechanicalexcellence 39Qualitychecks 40

Generalsaleterms 41Scientificbibliography 42Contacts 43

Page 5: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

11UNIVERSE |

Certificazioni

QualityMaintenanceisIML’sguidingprincipleinalifetimeproject embodied in the IML Production Protocol, aconstantly evolving tool applied to the daily productionofeachcomponent.IMLSAproductsaremarkedMedicalDevices:

•FDA 510 (k) approvedIMLSA’sQualityManagementforthedesign,manufacture,and marketing of dental implants, instrumentation, andrelated accessories complies with the Directives andregulationsinforce.

•EC (Class I) and EC 0425 (Class IIb and Class IIa),manufacturedinaccordancewithMedicalDevicesDirective93/42/EEC and subsequent modifi cation, amendments,andsupplements.

•[ICIM]UNI-ENISO9001:2015UNICEIENISO13485:2012

CERTIFICATIONS

Page 6: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

22 | UNIVERSE

Bestperformanceinthecases:

• any bone density• post extraction• delayed loading• immediate loading

UNIVERSE SYSTEM

Singleplatformforalldiameters

Micro-groovedCollar

SwitchingPlatform

Alternatingdoublespiral,square,andspur

Internalconnectionlockingthetapertotheinternaldodecagonusingapassingscrew

PassingscrewlockedbyaMorsetaperconnection

Self-tappingscrewtip

SLSurfaceTreatment

ConnectioninterfaceuptoH5.5mm

Page 7: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

33UNIVERSE |

Universe,withitsparticularconicalshape,offerssignificantbenefitsforawidespectrumofclinicalapplicationsalwaysprovidinggoodaestheticresults.

The implant features a highly innovative and ergonomicthreaddesign.This special morphology, due to the combination tothe spiral squared and spiral buttress threads, is able toincrease the implant surface by 20% compared to a thesameimplantwithoutbuttressthreadsprovidingagreaterand more uniform area of contact between bone andimplantspeedinguptheosteointegrationprocess.The alternate buttress and square double spiralloop generates a perfect balance between intrusive,compressive, and diverging forces capable of providingthebonewithexceptionalgrowthstimuli.Thestrongthreadsaredesignedfortheaddedcompressionandsurfacearearequiredinsoftboneplacementinorderto fill void spaces around the threads by ensuring animmediateprimarystability.

Indeed,Universe,showsexceptionalself-drillingpropertieswhichfacilitatetheimplantplacementandthedirectioninD1andD2bonetypes.

Universestandsoutforitsexcellentapicalpartdesignself-drillingandself-tapping.

Bestperformanceinthecases:• any bone density• post extraction• delayed loading• immediate loading

Implant Body

Page 8: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

44 | UNIVERSE

SL surface treatment

The IML Research and Developmentteam, in partnership with prestigiouschemistry laboratories which specialise inimplantology,hasformulatedtheoptimumsurfacetreatmentfortheirimplants:theSLtreatment.The performance monitoring has beenentrusted to the Polytechnic of Turinand to the University of Turin, which alsoperiodicallycheckproductionlots.IMLSLtreatmentistechnicallycomparableto the best SLA® treatments, the mostdocumentedintheliterature,anditiscarriedout using a sand-blasting technique, withdifferentgrainsizes,followedbyetchingofthesurfaceusingacidsolutions.The resulting surface has an appropriatestructure for anchoring osteoblasts andpromotesgood integrationof the implantwith the bone tissue. In fact, this type oftreatment suits any type of bone thanksto its ability to increase primary stabilityeven in the presence of atrophic sites orcompromisedbiologicaltissue.

Cell adhesion and roughness: laboratoryanalysisonIMLSLtreatedimplants

Aware of the key role played by thesurface treatment in determining thespeed and quality of osseointegration ofadental implant, IMLhasalways investedconsiderable resources in designingsurfaces that facilitate the cell adhesion.The tests carried out by the University ofTurin on implants with IML SL treatmentconfirmtheeffectivenessofthetopography

andofthesurfacechemistrydevelopedbytheIMLResearchandDevelopmentteam.According to reports of the University ofTurin and in accordance with protocolsof the international literature, 24 hoursafter cell seeding on Universe SL treatedimplants, it is possible to appreciate theuniformity of the growth and of the celladhesionovertheentireimplantsurface.Furthermore, observing by microscopethe nuclei (marked in blue) and thecytoskeleton (marked in red), it is evidentthatafter24hoursthecellsnotonlyhaveaverybranchedgrowth,with longfilopodiaand a complexmorphology, but they arealso multiplying in number. These are allindicatorsof thecellularbehaviourontheIMLSLtreatedsurface.(Pic1)

Another fundamental factor, determinedby the surface treatment and constantlymonitored by laboratory analysis, isthe roughness, that is the result of theunevennessonthesurface.During the surface analysis on Universeimplants, the CNR (National ResearchCouncil) of Turin examines the averageroughness(Ra/Sa),theSkewnessparameter(Rsk/Ssk), representing the prevalentsymmetry,andtheKurtosisparameter(Rku/Sku),representingtheindentationdensity.The resulting values, in relation to theinternational literature, confirm that theIML SL treated surfaces have an optimalroughness, homogeneously distributed.(Pic2)

Pic1.Detailsofthecellularmicrostructure-branchedanddendritic,withlongfilopodiaandcomplexmorphology-ofanIMLSLtreatedimplant.

Pic2.DetailsunderthemicroscopeofthesurfaceofanIMLSLtreatedimplant.

Page 9: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

55UNIVERSE |

Decontamination

Eventhedecontaminationprocessusedfor IMLimplantswas developed in collaboration with the Research andDevelopment team of our prestigious Italian universitiespartners.

This is a two-stage process, the second stage beingcomposed of passing the implants through a plasmareactor.The“PLASMAREACTOR”projectaimedtobuildamachinewithsuitablecharacteristics fortreatingdentalimplantsandtodefinetheoptimaloperatingprocedureandwasconductedincloseco-operationwiththeDepartmentof Applied Science and Technology of the PolytechnicUniversityofTurinandtheDepartmentofSurgicalSciencesattheUniversityofTurin’sCIRDentalSchool.

Phase1• Objective: inorganic waste removal, mechanicalmachining,andsurfacetreatmentsleaveresiduessuchascarbon and aluminium, universally considered possiblecausesofimplantsfailingtoosteointegrate;•Procedure:liquidsolutiontreatment;

Phase2• Objective: organic contamination removal, such asremovalofpro-inflammatoryagents;•Procedure:treatmentusinggascleaningagentsappliedviaanelectro-chemicalprocessperformed in theplasmareactor.

Page 10: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

6

The collar, which has microgrooves, ends witha smooth switching platform that becomesmore prominent as the diameter of the implant.It provides bone maintenance ensuring costantgingivaaestheticimpact.

Advantages:

•Increasedbonedistanceintheconnectionbetweenabutmentandimplant,thepointwherethebacterialloadattaches•Reductionofinflammatoryphenomena•Betterperi-implanttissuepreservation•Bettermaintenanceofcrestalbonelevel

Implant neck Taper internal connection

Atrue“coldwelding”inthetaperImplant-abutmentconnectionis produced by contact pressure between the surface of thefemale cone of the implant and that of themale cone of theabutment.Thefrictioncreatedbetweenthetwosurfacesofequalconicitytightenedto35Ncmgeneratesdirect,durable,andwaterproofinterlocking.Infact,thistypeofconnectionistheonlyonethatapproachestheidealconditionofamonoblockimplant,whichistheoneusedinthemonophasicsystem,universallyproventobelonger-lastingthanbiphasicsystems.However, being able tomechanically achieve a perfectMorsetapered connection requires great attention and special skillsstartingfromthedesignstage.IML’sdesignersandmechanicsknowhowtodetectandevaluateeachcriticalpointinordertoproduceperfectcomponentswhoseconnectionnotonlyworkswellduringtheprojectbutespeciallyalsointhepatient’smouththroughouttheirlife.As demonstratedby numerous studies carried out around theworld,theresultingsystemiseffectiveandreliable.(Bibliographypage42,rif.1)

Advantages:

•Eliminationofthepassageoffluidsandsobacterialcolonization•Eliminationofmicromovementsattheinterfacebetweenthecomponentsresultingingreatermechanicalstability•Lowincidenceofclinicalcomplications•Reductionofperi-implantinfections•Significantreductioninimplantfailures

Page 11: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

77UNIVERSE |

TheUniverseimplanthastheadvantageofalockingtaperconnectionwithapassingscrewwhichachievesapreciseandfunctionallyperfectfitwhencoupledwithadoubleinternalhexagon.Adesignchoicefacilitatingproceduresduringthesurgicalphase.

•Perfectantibacterialseal•12PossibleAbutmentPositionings

Thedecisivefactorinachievingcompletesystemstabilityistodeterminethefunctionofthepassingscrew,whichmustguaranteetheimplant-abutmentconnection.Thisworkisnoteasyasthescrewisrepeatedlysubjecttovibrationfatiguewhichnaturallytendstocausetheunscrewingofthescrewfromitsseat.HerethesolutionidentifiedbyIMListhetaperconnectionofthescrewheadinsidetheabutment.

TheUniverseimplantconnectionisnotonlydesignedtoguarantee correct implementationof thebenefitsofalockingtaperconnectionbutalsothoseofa“onepiece”implant.Inviewofthestudiesthatidentifytheconcentrationofmechanicalstressincorticalareasasapossiblecauseofboneresorption(Bibliographypage42,rif.2),theIML engineers have designed the Universe implantwith an internal geometry thatmakes it possible forthe implant-abutment-screwsystem tobehave likeasingleone-pieceimplantsystem.IndeedtheUniverseimplant-abutment-screwconnectionhasatotalheightuptoabout5.5mm.Thebenefitofthisisbetterdistributionoftheloadandthelevers,whichspread80%oftheforcethroughoutthesysteminsteadofonlycentringthemonthecorticalareaasisfrequentlythecaseinotherimplantsystems.(Bibliographypage42,rif.3)

Load50NσvonMises=28.23N/mm2 Load150NσvonMises=84.86N/mm2 Load250Nσ vonMises=140.75N/mm2 Load500Nσ vonMises=273.97N/mm2

Page 12: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

88 | UNIVERSE

SURGICAL KITS

Page 13: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

99UNIVERSE |

THIS DESIGN IS THE PROPER T Y OF THE IPPI SRL. IT IS PROHIBITED TO COPY OR REPRODUCE UNAUTHORIZED OF THIS DOCUMENT OR ANY PAR T THEREOF, ALL RIGHTS ARE RESER VED.

QUESTO DISEGNO È DI PROPRIE TÀ DELLA IPPI SRL. È VIE TATA LA COPIA E LA RIPRODUZIONE NON AUTORIZZATE DI QUESTO DOCUMENTO O PAR TE DI ESSO, TUT TI I DIRIT TI SONO RISER VATI .

QU

ESTO

DIS

EGN

O È

DI

PR

OP

RIE

TÀ D

ELLA

IP

PI

SRL.

È V

IETA

TA L

A C

OP

IA E

LA

RIP

RO

DU

ZIO

NE

NO

N A

UTO

RIZ

ZA

TE D

I Q

UES

TO D

OC

UM

ENTO

O P

AR

TE D

I ES

SO, T

UT

TI I

DIR

ITTI

SO

NO

RIS

ERVA

TI.

THIS D

ESIGN

IS THE P

RO

PER

TY

OF TH

E IPP

I SRL. IT IS P

RO

HIB

ITED TO

CO

PY

OR

REP

RO

DU

CE U

NA

UTH

OR

IZED

OF TH

IS DO

CU

MEN

T OR

AN

Y PA

RT TH

EREO

F, ALL R

IGH

TS AR

E RESER

VED

.

L_871_1016_00_00 1/1

Ponzilacqua NicoDATA : 10 10 2019

Parte 01 Vassoio: RADEL R 5100NT15 BIANCO Parte 02 Fondo: RADEL R 5100NT15 BIANCO

Parte 03 Coperchio: RADEL R 5000CL301

00

Layout di stampa olv VisictyNUMERO DI DISEGNO / DRAWING NUMBER FOGLI / SHEETS SCALA / SCALE

1:1FORMATO / SIZE

A2

DESCRIZIONE / DESCRIPTION REDATTO DA / EDITED BY

MATERIALE / MATERIAL MASTER

MODIFICHE / MODIFICATIONS

REV

REVISIONI /REVISION

DATA REVISIONI /DATE REVISION

TOLLERANZE GENERALI / GENERAL TOLLERANCE

UNI EN 22768 - m ISO 2768 - mUNI EN 22768 - K ISO 2768 - K

APPROVATO DA / APPROVED BY

firma / signature

IPPI SRLvia Brodolini 22, 24, 26

Loc. Crespellano40053 Valsamoggia (BO)

tel. +39 051969510fax +39 0516720648p. iva 00305440372MAIL: [email protected]

BOZZA rev. DRAFT rev. 03

SILICON PARTS COLORS

AZZURRO/LIGHT BLUE : PANTONE 290

BIANCO/WHITE : RAL 9010

BLU/BLUE : RAL 5015

GIALLO/YELLOW : RAL1016

GRIGIO/GREY : RAL7040

MARRONE/BROWN : RAL8024

ROSSO/RED : RAL3020

VERDE/GREEN : RAL6032

ARANCIONE/ORANGE : RAL2003

VIOLA/PURPLE : PANTONE 265

NERO/BLACK

FUCHSIA : RAL 4003

C

D

F

A

E

B

= Ø 1,5mm

= Ø 2mm

= Ø 4mm

= Ø 5mm

= Ø 6mm

= Ø 7mmSILI

CON

SU

PPO

RTS

SEPA

RATE

LY S

UPP

LIED

*

*

Piedini (opzionali), colore *Feet (optional), colors*

Piedini (opzionali), colore *Feet (optional), colors*

QR CODE URL :http://www.immediateload.com/UNCD191.pdf

Universe

Ø5-6pØ4-6p

A

GREY

A

GREY

A

GREY

A

GREY

A

GREY

A

GREY

A

GREY

A

GREY

A

GREY

A

RED

A

RED

A

RED

A

RED

A

RED

A

RED

A

RED

A

RED

Ø7

Ø7

RED

E

RED

E

Implant DriversDrivers Ex.1,26

H10 H15H10 H15 H10 H15

Guide Pin

Extractor Mua

Precision Ø2 Ø2.7 Ø3.1 Ø3.6 Ø3.9 Ø4.4 Ø4.9DrillExtension

Drill Stop Ø2 - Ø2.7 - Ø3.1 - Ø3.6 - Ø3.9 Drill Stop Ø4.4 - Ø4.9

Ed. 2020-00

PANTONE 428 C

UniverseCYLINDRICAL DRILL PROTOCOL

42.0

TherearetwosurgicalkitoftheUNIVERSEimplantsystem:CD(cylindricaldrillsurgicalprotocol)andTD(tapereddrillsurgicalprotocol).Surgicalboxesaredesignedformaximumsimplicilityofuseandmadeentirelyofplasticmaterialssuitableforsteamsterilisation.Theinstrumentpositionsareclearlylabelledinordertofacilitateidentificationduringthesurgicaloperationandtocorrectlyreplacethemafterthemaintenanceprocedure.Thesiliconsupportssecuretheinstrumentsfirmlyduringtransportationandsterilisation.

Thekitcontainsstopsthatallowdrillstobeusedsafelyandtheyaresuppyseparately.Cylindricaldrillsandpilotdrillsaremarkedwithindicatorsreferringtoimplantheightanddrillstops.

AllIMLsurgicalinstrumentsaremanufacturedinSurgicalSteelofthehighestqualitythatoffersthebestperformanceintermsofwearresistanceandtorque.Tofollowcarefullythedirectionsofthesurgicalandprostheticprotocolandtheinstructionsforcleaningandmaintenanceoftheproductsensurestheoptimallong-termperformanceandreliabilityforwhichproductsweredesigned.

Usingasmartphone,theQRcodeprintedontheboxallowstodisplaythesurgicalprotocolanddownloaditfromimmediateload.com

CD surgical kit TD surgical kit

Page 14: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1010 | UNIVERSE

Tools

UniverseCDbox for surgicalinstruments

BOX-UNCD

Universe TDbox for surgicalinstruments

BOX-UNTD

Precisiondrill

U

0.5 SFYS18ø

H

CylindricalpilotdrillforUniverseCD

2.0 SFYS19

DrillØ

CylindricalpilotdrillforUniverseTD

2.0 FL30-UøDrill

Drillstopskitforpilotdrill(6pcs)forUniverseTD

STF-KIT

Drillextension

PR-FR

Guidepin

UN-PIN

Conicaldrill

6 8 10 11.5 13 15

3.4 FC34-6 FC34-8 FC34-10 FC34-11.5 FC34-13 FC34-15

4 FC40-6 FC40-8 FC40-10 FC40-11.5 FC40-13 FC40-15

4.5 FC45-6 FC45-8 FC45-10 FC45-11.5 FC45-13 FC45-15

5 FC50-6 FC50-8 FC50-10 FC50-11.5 FC50-13 FC50-15

Implantø

ImplantH

FC34-6isdesignedforimplantØ4h6

ReddrillstopskitfordrillsfromØ2toØ4forUniverseCD

SFYS042

Page 15: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1111UNIVERSE |

GreendrillstopskitfordrillsfromØ4.4forUniverseCD

SFYS043

Cylindricaldrill

2.7 SFYS21

3.1 SFYS22

3.6 SFYS23

3.9 SFYS20

4.4 SFYS25

4.9 SFYS55

Implantdriverformotor

10 15

AVM-C AVM-L

H

Multitoolimplantdriver

10 15 25

CCIB-10 CCIB-15 CCIB-25

H

Tools

Dynamometricratchet

DN-I

Torquerange:15-45Ncm

Fixedratchet

CR-U

Multitooldriverforscrews

10 15

CCIV-10 CCIV-15

H

Digital adapter for multitooldriver

SFYS051

Motordriverforscrews

6 12 17

SFYS011 SFYS012 SFYS013

H

Smartpegforimplant

SM-PEG

Multitoolremoverforabutment

IMESTR-U1

MultitooldriverforstraightMUA

AMM-U

MotordriverforstraightMUA

SFYS016

Page 16: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1212 | UNIVERSE

SURGICAL PLANNING

Page 17: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1313UNIVERSE |

A B C D E F G H

CODEIMPLANTMEASURE(ØxH)

COREØATTIP

THREADØATTIP

IMPLANTØINTERFACE

ØTHREADPITCH

SURFACETREATMENT

H

SWITCHINGPLATFORMH

IMPLANT H

IM34-8 3.4X8 1.35 2.75 3.7 3.3 1.2 7.8 0.2 8

IM34-10 3.4X10 1.35 2.75 3.7 3.3 1.2 9.8 0.2 10

IM34-11.5

3.4X11.5 1.35 2.75 3.7 3.3 1.2 11.3 0.2 11.5

IM34-13 3.4X13 1.35 2.75 3.7 3.3 1.2 12.8 0.2 13

IM34-15 3.4X15 1.35 2.75 3.7 3.3 1.2 14.8 0.2 15

IM40-6 4X6 1.95 2.9 4 3.6 1.2 6.1 0.9 7

IM40-8 4X8 1.45 3.15 4 3.6 1.2 7.8 0.2 8

IM40-10 4X10 1.45 3.15 4 3.6 1.2 9.8 0.2 10

IM40-11.5 4X11.5 1.45 3.15 4 3.6 1.2 11.3 0.2 11.5

IM40-13 4X13 1.45 3.15 4 3.6 1.2 12.8 0.2 13

IM40-15 4X15 1.45 3.15 4 3.6 1.2 14.8 0.2 15

IM45-6 4.5X6 1.8 3.45 4.5 3.9 1.2 6.1 0.9 7

IM45-8 4.5X8 1.8 3.45 4.5 3.9 1.2 7.8 0.2 8

IM45-10 4.5X10 1.8 3.45 4.5 3.9 1.2 9.8 0.2 10

IM45-11.5

4.5X11.5 1.8 3.45 4.5 3.9 1.2 11.3 0.2 11.5

IM45-13 4.5X13 1.8 3.45 4.5 3.9 1.2 12.8 0.2 13

IM45-15 4.5X15 1.8 3.45 4.5 3.9 1.2 14.8 0.2 15

IM50-6 5X6 2.2 3.8 5 4.2 1.3 6.1 0.9 7

IM50-8 5X8 2.2 3.8 5 4.2 1.3 7.8 0.2 8

IM50-10 5X10 2.2 3.8 5 4.2 1.3 9.8 0.2 10

IM50-11.5 5X11.5 2.2 3.8 5 4.2 1.3 11.3 0.2 11.5

IM50-13 5X13 2.2 3.8 5 4.2 1.3 12.8 0.2 13

IM50-15 5X15 2.2 3.8 5 4.2 1.3 14.8 0.2 15

Ø 2,882,2

Surgical Planning

UNITOFMEASUREMENT:mm

Coverscrewincluded

OPTIONAL:Thecoverscrewforboneringcanbepurchasedseparately

E

D

G

FH

A

B

C

Page 18: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1414 | UNIVERSE

Preparation (Cylindrical drill surgical protocol)

Page 19: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1515UNIVERSE |

CD Surgical Protocol

TheUniverseCDSurgicalProtocolhasbeendevelopedtoprovidesurgeonswithindicationsonhowtochoosethemostsuitableinstrumentsforimplantsitepreparation,dependingonthetypeofbone.However,itisthedutyofthesurgeontoapplythemostappropriatesurgicalprotocol on the basis of his/her experience and following a thoroughassessmentoftheclinicalsituationoftheindividualpatient.Forthepreparationoftheimplantsite,IMLhasdevelopedcylindricaldrillswithataperedtipanddepthmarks inaccordancewiththelengthoftheimplant;theycanbeusedwithdrillstops.IncaseofdenseD1bone,adequatecorticalbonepreparationisessentialinordertoallowtheimplanttobeinsertedsmoothlyinthebone.

IMPORTANT:-Drillspreparethesite0.7mmmorethantheheightoftheimplant.-Theimplantissuppliedcompletewithcoverscrew-Recommendedtorquemax:45Ncm

Fig.exampleofCDdrillingsequenceindenseboneofimplantØ3.4h10

Page 20: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1616 | UNIVERSE

Preparation (Tapered drill surgical protocol)

Page 21: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1717UNIVERSE |

TD Surgical Protocol

The Universe TD Surgical Protocol has been developed to provide thesurgeonwiththemostappropriatetoolsforbonecompliance,andisalsosimpleandpractical.ThepreparationoftheimplantsitefortheUniverseimplantiscompletedin3simplesteps,afterwhichtheimplantcanbeinsertedeasily:

The preparation of the implant site is performed by tapered drills thatoptimisetheboneavailabletoplacetheimplant,withoutwaste.Thesedrillsaresizedatthecoreofeachsinglediameterandheightoftheimplanttofacilitatethedrillingprotocolreducingittothreesimplesteps.Theparticulartipshapeguidestheprogressiveadvancement,respectingtheboneandpreparingacustomizedsite.However, it is thedutyofthesurgeontochoosethemostappropriatesurgicalprotocolbasedonhisorherexperiencefollowingathoroughassessmentoftheindividualpatient’sclinicalsituation.

IMPORTANT:-Drillspreparethesite0.3mmmorethantheheightoftheimplant.-Theimplantissuppliedcompletewithcoverscrew-Recommendedtorquemax:45Ncm

1° step 2° step 3° step

Implant Ø5

Implant Ø4.5

Implant Ø4

Implant Ø3.4

Precision drill Pilot drill Ø2 Drill Ø3.4

Precision drill Pilot drill Ø2 Drill Ø4.0

Precision drill Pilot drill Ø2 Drill Ø4.5

Precision drill Pilot drill Ø2 Drill Ø5.0

Fig.exampleofTDdrillingsequenceofimplantØ4h10

Page 22: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1818 | UNIVERSE

PROSTHETIC PLANNING

Page 23: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

1919UNIVERSE |

COMING SOON2020

NEW PACKAGING

CAD/CAM

FLEXATOR

Page 24: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2020 | UNIVERSE

Impression taking

Page 25: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2121UNIVERSE |

Lab components

Opentrayimpressioncoping(*)

U TRA-Uø

Slimopentrayimpressioncoping(*)

U TRA-SLø

Bridgeopentrayimpressioncoping(*)

U TRA-Pø

Closedtrayimpressioncoping(*)

U TRA-Cø

(*)Specificscrewforimpressioncopingincluded.

Tear-offclosedtrayimpressioncoping

U TRA-Sø

Implantreplica

U ANI-Uø

Page 26: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2222 | UNIVERSE

Restoration

Page 27: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2323UNIVERSE |

Prosthetic parts

Healingscrew

1 2 3 4 5

U MGIU-1 MGIU-2 MGIU-3 MGIU-4 MGIU-5

H

Ø

Shifthealingscrew

1 2 3

U MGIU-21 MGIU-22 MGIU-23

H

Ø

Slimhealingscrew

U MGIU-0Ø

Bridgepeekhealingscrew(**)

U MGIU-99Ø

(**)Connectingscrewforpeekandtemporaryabutmentincluded.

Page 28: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2424 | UNIVERSE

Prosthetic parts

(**)Connectingscrewforpeekandtemporaryabutmentincluded.

Peektemporarystraightabutment(**)

0

U MDIU-100

H

Ø

15°angledpeektemporaryabutment(**)

0

U MIU15-100

H

Ø

Temporarystraightabutment(**)

0

U MDIU-101

H

Ø

SpareConnectingscrewforpeekandtemporaryabutment

VT-K

Page 29: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2525UNIVERSE |

Straightabutment(*)

0

U MDIU-0

H

Ø

Aestheticstraightabutment(*)

1 2 3 4

U MDIU-1 MDIU-2 MDIU-3 MDIU-4ø

H

Shiftaestheticstraightabutment(*)

1 2 3

U MDIU-21 MDIU-22 MDIU-23ø

H

Slimstraightabutment(*)

0

U MDIU-013

H

Ø

Prosthetic parts

(*)Connectingscrewabutmentincluded.

Page 30: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2626 | UNIVERSE

TBaseabutment(*)

1 2

U MDIU-51 MDIU-52ø

H

RotatingTBaseabutment(*)

1 2

U MDIU-53 MDIU-54ø

H

Flattoflatstraightabutment(*)

U MDIU-99Ø

15°angledabutment(*)

0

U MIU15-0

H

Ø

(*)Connectingscrewabutmentincluded.

Prosthetic parts

Page 31: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2727UNIVERSE |

Aesthetic15°angledabutment(*)

1 2 3

U MIU15-1 MIU15-2 MIU15-3ø

H

Aesthetic25°angledabutment(*)

1 2 3

U MIU25-1 MIU25-2 MIU25-3ø

H

Shiftaesthetic15°angledabutment(*)

1 2 3

U MIU15-21 MIU15-22 MIU15-23ø

H

Largeballabutment

1 2 3 4

U OTKIU-1 OTKIU-2 OTKIU-3 OTKIU-4ø

H

Prosthetic parts

(*)Connectingscrewabutmentincluded.

Page 32: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2828 | UNIVERSE

Titaniumclosedcapforlargeball

4.1

SFYP062

H

Titaniumopencapforlargeball

2.6

SFYP063

H

Spare

O-ring(10pcs)

GOM-I

NonrotatingCr/Cobasecalcinableabutment(*)

1

U MDIU-70

H

Ø

Prosthetic parts

(*)Connectingscrewabutmentincluded.

Page 33: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

2929UNIVERSE |

Prosthetic parts

RotatingCr/Cobasecalcinableabutment(*)

1

U MDIU-71

H

Ø

Calcinablenonrotatingabutment(*)

2

U CALI-U

H

Ø

SpareConnectingscrewforabutment

VT-P

(*)Connectingscrewabutmentincluded.

Page 34: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3030 | UNIVERSE

MUA positioning

Page 35: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3131UNIVERSE |

MUA

StraightMUA

1 2 3

U CDIU-1 CDIU-2 CDIU-3

H

Ø

17°angledMUA(*)

3 4

U CIU17-3 CIU17-4

H

Ø

30°angledMUA(*)

3 4 5

U CIU30-3 CIU30-4 CIU30-5

H

Ø

(*)ConnectingscrewforangledMUAincluded.

Page 36: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3232 | UNIVERSE

MUA impression taking

Page 37: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3333UNIVERSE |

MUA open tray impressioncoping(*)

SFYP076

OPTIONAL:LongscrewforMUAimpressioncoping

20

SFYV011

H

MUAreplica

SFYP077

(*)ConnectingscrewH15forMUAimpressioncopingincluded.

MUA lab components

Page 38: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3434 | UNIVERSE

MUA restoration

Page 39: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3535UNIVERSE |

MUA prosthetic parts

MUAhealingcap(*)

SFYP075

MUApeektemporarycylinder(*)

SFYP101

MUAtitaniumcylinder(*)

SFYP078

MUACr/Cobasecalcinablecylinder(*)

SFYP100

MUAcalcinablecylinder(*)

SFYP079

Spare

M1.4connectingscrewforMUAprostheticparts

SFYP009

Max15Ncm

(*)M1.4connectingscrewforMUAprostheticpartsincluded.

Page 40: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3636 | UNIVERSE

PACKAGING

Page 41: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3737UNIVERSE |

UNIVERSE CONICAL IMPLANT Ø4.0 H10 UNIVERSE IMPIANTO CONICO Ø4.0 H10

IM40-10 008423

2024-05

0425

IML SA, via Moree,16 -6850 Mendrisio - (Switzerland)

LOT

Nameofproduct

Donotuseifpackagingis

damaged

Warning,pleasereadencloseddocuments

Diameter

Manufacturer Donotre-sterilize

Sterilizeddevice

Productcode

Single-usedevice

Lenght

Lotnumber

UsebyYYYY-MM

AllIML’sproductsareCEincompliancewiththeDirective93/42/CEE.

IML’spackagingprocessisperformedincompliancewiththestandardssetbytheEC93/42Directive,whichguaranteethesterilisationshelf-life.TheIMLimplantsaresterilisedbybetarays.Theimplantsarepackagedinavialthat,inturn,isplacedinsideaplasticcontainersafetysealcap.Thentheplasticcontainerisplacedinsideacardboardboxbearingaremovablelabel,bearingtheimplantinformationdetails.Furthertwocopiesofthelabelareintothecardboardbox,tobeplacedontheimplantpassportandonthepatient’smedicalrecordsheet.

ThemethacrylatevialwithPolyethylene(PE)topiscarefullywashedanddried

Thecardboardbox(3.5x6,2x3,5cm)mustbestoredinadryplaceatroomtemperature

ThetransparentPolyethyleneTerephthalate(PET)containerisclosedwithawhitePolypropylene(PP)stopperwithasafetyseal

Packaging

Page 42: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3838 | UNIVERSE

ABOUT US

The Swiss company IML SA Swiss DentalImplants was founded in 2009 by a close-knit team of professionals with twenty-yearexperience in the dental industry, especiallydealingwithimplants.Itsengineerscontinuouslystrivetofindeffectivesolutionsfornewimplantologyneeds,onesthatmeettheexpectationsofthemostdemandingprofessionals.Main aim: to offer oral implantology that isSimple,SafeandStablethroughtime.These “3Ss” summarise the guidelines theCompanyhasestablishedforitsownstandardsandarepursuedineveryactionittakeseveryday.

Page 43: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

3939UNIVERSE |

Onlythebestrawmaterials,themostadvancedtechnology,andthebestprofessional.These secrets of IML guarantee excellent products, free frommanufacturingdefects.

•Super-skilledoperatorsabletodevelopaman-machinerelationshipabletooptimisethefeaturesoftheirtoolstoachievemaximumperformance•Topqualitytitaniumformedicaluse.grade4forimplantsandgrade5 forprostheses. IML titanium isexclusively imported fromtheUnitedStates,isguaranteedfreefrommanufacturingdefectsandradioactivity•Mechanicalproductionusinglatestgenerationslidingheadmachines

Men, materials and machines

How important is it for themechanical work in the connection of animplantorintheheadofascrewtobewell-executed?

Justasimportantasitisthattheabutmentremainswellscrewedtotheimplant.IMLisfullyawareoftheissuesgeneratedbyalltypesofproductiondefectsandknowshowtoresolvethem,andaboveall,itknowshowtoobtain,andsystematicallyrepeat,aPERFECTMECHANICALEXECUTION.Forexample,IMLguarantees5thousandthsofamillimetertoleranceonthemeasureofthehexagonalconnectionoftheimplent,oneverysingleimplant.

Mechanical excellence

Page 44: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

4040 | UNIVERSE

Controlofqualityorquality control?Aplayonwords,useful inexplainingthatcheckingisnotenoughforIML.ControlinIMLissynonymouswithuncompromisingeliminationofallthosecomponentsthatpresenttheslightestimperfectionevenifonlyaesthetic.It means making a commitment to selling only very specificcomponentsinordertobe“aspreciseastheSwiss”.ItmeansthatwemustfullytakeonthecostofthiscommitmentbothpursuedandmaintainedethicallyandproudlybyIMLandbytakingthepatient’shealthandthesurgeon’sskillsintoconsideration.

Process:

•Identificationofeachindividualcomponent’scriticalpoints

•Draftingdocumentswith a list of the critical points specific toeachindividualcomponentindicatingthesequenceofcheckstobecarriedout

• Over 30 checks are performed on 100% of the componentsmanufacturedinthevariousmanufacturingphases:-Dimensionalcontrols-Removalofburrsanddross-Functionalteststoremovenon-perfectcomponentsareperformedon100%ofthecomponents

•Theoperatorsignsoffeachchecktocertifythatheorsheacceptsresponsibilityforthechecksmade

•Regularlaboratoryanalysescheckconformityofimplantsurfaces

Quality checks

Page 45: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

4141UNIVERSE |

VALIDITYThiscatalogueisthe2019_1editionandreplacesanypreviouseditions.

EXCLUSIONOFRESPONSIBILITYThedentalimplantsmanufacturedbyIMLSA(hereinafteralso“IML”)andotherIMLmedicaldevicesmaybeusedonlywithoriginalIMLcomponentsandinstruments,followingtheinstructionsprovidedinsidethepackage.TheuseofdevicesmanufacturedbyothercompaniesormanufacturedbyIML,butnotbelongingtothesameimplantlineshallinvalidatethewarrantyandterminateanyexplicitorimplicitobligationofIML.Theclinicalprotocolsprovidethepractitionerwithareferenceguideandshallnotbeconstruedasanalternativetotheuser’strainingandprofessionalexperience.ThepractitionerusingIMLmedicaldevicesmustensurethatdevicebeingusedissuitedtothepatientandtoexistingcircumstances.IMLdoesnotacknowledgeanyexplicitorimplicitresponsibility,norshallithaveanyresponsibilityforanydirect,indirect,criminalorotherdamagederivingfromorassociatedwithanymistakesinprofessionaljudgements,inthepracticalapplicationorinsertionofIMLproducts.Thepractitionerisalsoundertheobligationtokeepup-to-dateatalltimeswiththemostrecentdevelopmentsandapplicationsofIMLmedicaldevices.Anydescriptionsoftheproducts,depictions,illustrationsincatalogues,illustrativeandsalesmaterials,pricelistsorotherinformativedocumentsissuedanddistributedbyIMLinanyformareprovidedonlyforexplicativepurposes.ThePurchaseracknowledgesthathe/shedoesnotpurchasetheproductsonthebasisofsuchdescriptionsand/orillustrations.

PRODUCTSMODIFICATIONSTheimagesoftheproductsshowninthecatalogues,andinallIMLpublications,areforillustrativepurposesonly.IMLreservestheright,atanytimeandatitssolediscretion,tomakechangestotheproducts,codesanddescriptionswithoutobligationofnotice.

COPYRIGHTANDTRADEMARKSProtectionofprivacypursuanttolaw.ItisstrictlyprohibitedtocopyorpublishalloranypartofthiscataloguewithoutthewrittenauthorisationofIMLinanypaperandelectronicform.

ORDERPLACEMENTIMLdentalimplantsandmedicaldevicescanbeorderedbyquotingtheproductcodeanddesiredquantity,inthefollowingways:

Telephone:0041(0)916001310Mon–Fri09:00-13:00/14:00-17:00,E-mail:[email protected]

PRODUCTSHIPMENTSExceptintheeventofforcemajeure,goodswillbeshippedtotheaddressindicatedbytheclientaccordingtothetermsindicatedbythesupplieratthetimeofacceptanceoftheorder.

RETURNEDMATERIALSTherighttohavepurchasedproductsreplacedmaybeexercisedwithin5workingdaysfromtheproductsdeliverydateandmustbepre-authorisedbyIMLinwriting.Therighttoreplacementshallbecancelledintheeventtheproductintegrity(packagingand/oritscontent)iscompromised.ForexampleinthecasesinwhichIMLobserves:-thatthepackagehasbeenopened-thatthepackagehasbeendamaged(evenifstillsealed)-thattheproducthasbeendamagedotherthanfortransportation.IfIMLdoesnotaccepttoreplacetheproduct,itwillreturnit,chargingshipmentcoststothePurchaser.

PRICESThevaluesindicatedintheofficialpricelistarenetofVAT,transportcostsandanybankchargesforpaymentcollection.Unlesspreviouslyagreedotherwise,priceschargedwillbetheonesindicatedintheofficialpricelistinforceatthetimeoftheorderacceptance.

CHANGESTOTHEPRODUCTSANDPRICESIMLreservestherighttomakechangestotheproductscontainedinthiscatalogueandtotheirpricesortodiscontinuetheirproductionatanytime,withouthavingtogivepriornotice.

APPLICABLELAWANDJURISDICTIONTheseSalesTermsshallbegovernedandinterpretedaccordingtoSwissCivilCodeandtheexclusiveplaceofjurisdictionshallbethecourtsofLugano.

General sale terms

Page 46: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

4242 | UNIVERSE

ConnessioneConometricaMorse-taperconnection•DiCarloF,MarincolaM,QuarantaA,BediniR,PecciR(2008)AnalisiMicroTacdiimpiantiaconnessioneconometrica.DentCadmos76(3):1-6.•BediniR,IoppoloP,PecciR,RizzoF,DiCarloF,QuarantaM(2007)Studioinvitrosullaconnessionedisistemiimplantaridentali.RapportiISTISAN07/7.•HermannJS,SchoolfieldJD,SchenkRK,BuserD,CochranDL(2001)Influenceofthesizeofthemicrogaponcrestalbonechangesaroundtitaniumimplants.Ahistometricevaluationofunloadednon-submergedimplantsinthecaninemandible.JPeriodontol72:1372-1383.•CrespiR,CappareP,GherloneE.Radiographicevaluationofmarginalbonelevelsaroundplatform-switchedandnon-platform-switchedimplantsusedinanimmediateloadingprotocol.IntJOralMaxillofacImplants2009.•DibartS,WarbingtonM,SuMF,SkobeZ(2005)Invitroevaluationoftheimplant-abutmentbacterialseal:thelockingtapersystem.IntJOralMaxillofacImplants20:732-737.•PerssonLG,LeckholmU,LeonhardtA,DahlenG,LindheJ(1996)BacterialcolonizationoninternalsurfacesofBranemarksystemimplantcomponents.ClinOralImplantsRes7:90-95.•HanssonS.Implant-AbutmentInterface:BiomechanicalstudyofFlatTopversusConical.2000:Biomechanics,departmentofpolymericmaterials,ChalmersUniversityofTechnologyGoteborg,Sweden.•DibartS.etal.Invitroevaluationfortheimplant-abutmentbacterialseal:ThelockingTapersystem.Int.J.OralMaxillo-facialImplants.2005;20:732-737.

RiassorbimentoosseoBonereabsorbtion•Horowitz,R.,CurrentImplantDesignstoMaintainCrestalBoneandGingiva,FunctionalEsthetics&RestorativeDentistry:Series1,Number2,DentalImplants,p.88-90,2008.•KitamuraE,StegaroiuR,NomuraS,MiyakawaO.Influenceofmarginalboneresorptiononstressaroundanimplant—Athree-dimensionalfiniteelementanalysis.JOralRehabil2005;32:279–286.•KingGN,HermannJS,SchoolfieldJD,BuserD,CochranDL.Influenceofthesizeofthemicrogaponcrestalbonelevelsinnon-submergeddentalimplants:aradiographicstudyinthecaninemandible.JPeriodontol.2002;73(10):1111-7.•TawilG,AboujaoudeN,YoumanR.Influenceofprostheticparametersonthesurvivalandcomplicationratesofshortimplants.IntJOralMaxillofacimplants2006;21(2):275-282.5)Leonard,G.,Coelho,P.,Polyzois,I.,Stassen,L.,Claffey,N.,Astudyofthebonehealingkineticsofplateauversusscrewrootdesigntitaniumdentalimplants.ClinicalOralImplantsResearch,2009,20(3),232-239.•TadaS,StegaroiuR,KitamuraE,MiyakawaO,KusakariH.Influenceofimplantdesignandbonequalityonstress/straindistributioninbonearoundimplants:A3-dimensionalfiniteelementanalysis.IntJOralMaxillofacImplants2003;18:357–368.•Bozkaya,D.,andMüftü,S.,Muftu,A.,EvaluationofLoadTransferCharacteristicsofFiveDifferentImplantSystemsinCompactBoneatDifferentLoadLevelsbyFiniteElementAnalysis.JournalofProstheticDentistry,Vol.92No.6,p.523-530,December2004.•BidezMW,MischCE.Issuesinbonemechanicsrelatedtooralimplants.ImplantDent1992;1(4):289-294.9)PetrieCS,WilliamsJL.Shapeoptimizationofdentalimplantdesignsunderobliqueloadingusingthep-versionfiniteelementmethod.JMechanicsMedBiol2002;2:339–345.•Lemons,J.E.,Biomaterials,Biomechanics,TissueHealing,andImmediate-FunctionDentalImplants,JournalofOralImplantology,Vol.XXXNo.5,2004.•Venuleo,C.,Chuang,S.K.,Weed,M.,Dibart,S.,LongtermbonelevelstabilityonShortImplants:Aradiographicfollowupstudy.IndianJournalofMaxillofacialandOralSurgery,September2008,Vol.7:No.3,p.340-345.•Mericske-SternR,GrutterL,RoschR,etal:Clinicalevaluationandprostheticcomplicationsofsingletoothreplacementsbynon-submergedimplants.ClinicalOralImplantsRes2001;12:309-318.•DibartS,WarbingtonM,FanSuM,etal:Invitroevaluationoftheimplant-abutmentbacterialseal:theLockingTapersystem.IntJOralMaxillofacialImplants2005;20:732-737.•LiShi,AlexS.L.Fox.ShapeOptimizationofDentalImplants.l.IntJOralMaxillofacImplants.22:911-920;2007.15)RenouardF,NisandD,Impactofimplantlengthanddiameteronsurvivalrates.ClinicalOralImplantsRes.2006Oct;17Suppl2:35-51.•Schulte,J.,Flores,A.,Weed,M.,Crown-to-implantratiosofsingletoothimplant-supportedrestorations,JournalofProstheticDentistry,Vol98,Issue1,July2007,Pages1UNIEN1642.Dispositivimediciperl’odontoiatria.Impiantidentali.Milano:EnteNazionaleItalianodiUnificazione;1997.ISOTR11175.Dentalimplants.Guidelinesforde¬velopmentdentalimplants.Geneva:InternationalOrganizationforStandardization;1993.•BrunskiJB.Biomaterialsandbiomechanicsinden¬talimplantdesign.IntJOralMaxillofacImplants1988;3(2):85-97.•LekholmU,ZarbGA.Tissueintegratedprostheses:osseointegrationinclinicaldentistry.Chicago:Br¬anemark,Zarb&AlbrektssonEds.;1985.•AlbrektssonT,BränemarkPI,HanssonHA,Lind¬stromJ.Osseointegratedtitaniumimplants.Re¬quirementsforensuringalonglasting,directboneanchorageinman.ActaOrthopScand1981;52(2):155-70.•AdellR,LekholmU,RocklerB,BränemarkPI.A15-yearstudyofosseointegratedimplantsinthetreatmentoftheedentulousjaw.IntJOralSurg1981;10(6):387-416.•BränemarkPI,AdellR,BreineU,HanssonBO,Lind¬stromJ,OhlssonA.Intra-osseousanchorageofdentalprosthesesI.Experimentalstudies.ScandJPlastReconstrSurg1969;3:81-100.•AsikainenP,KlemettiE,VuilleminT,SutterF,RainioV,KotilainenR.Titaniumimplantsandlateralforc¬es.Anexperimentalstudywithsheep.ClinOralImplantsRes1997;8(6):465-468.•KeltjensHMAM,CreugersTJ,CreugersNHJ.Threedifferentfillingmaterialsinoverdentureabut¬ments;a30-monthsevaluation.JDentRes1997;76(5):1103.•WeinlaenderM.Bonegrowtharounddentalim¬plants.DentClinNorthAm1991;35:585-601•M.Marincola,L.Paracchini,V.Morgan,J.Schulte.Impianticorti:principibiomeccaniciepredicibil¬itàalungotermine.QuintessenzaInternazionale2008,Settembre-Ottobre2008,45-53,24,5bis.•M.Danza,I.Zollino,L.Paracchini,G.Riccardo,S.Fanali,F.Carinci.3Dfiniteelementanalysistode¬tectstressdistribution:Spiralfamilyimplants.J.Maxillofac.OralSurg8(4):334-339.

CarichieleveLoadingandleverage•BrunskiJB.Biomaterialsandbiomechanicsindentalimplantdesign.IntJOralMaxillofacImplants.1988;3(2):85–97.•AlbrektssonT,BränemarkPI,HanssonHA,LindstromJ.Osseointegratedtitaniumimplants.Requirementsforensuringalonglasting,directboneanchorageinman.ActaOrthopScand.1981;52(2):155–70.•AdellR,LekholmU,RocklerB,BränemarkPI.A15-yearstudyofosseointegratedimplantsinthetreatmentoftheedentulousjaw.IntJOralSurg.1981;10(6):387–416.•BränemarkPI,AdellR,BreineU,HanssonBO,LindstromJ,OhlssonA.Intra-osseousanchorageofdentalprosthesesI.Experimentalstudies.ScandJPlastReconstrSurg.1969;3:81–100.•AsikainenP,KlemettiE,VuilleminT,SutterF,RainioV,KotilainenR.Titaniumimplantsandlateralforces.Anexperimentalstudywithsheep.ClinOralImplantsRes.1997;8(6):465–468.•KeltjensHMAM,CreugersTJ,CreugersNHJ.Threedifferentfillingmaterialsinoverdentureabutments;a30-monthsevaluation.JDentRes.1997;76(5):1103.•DanzaM,ZollinoI,ParacchiniL,RiccardoG,FanaliS,CarinciF.3Dfiniteelementanalysistodetectstressdistribution:Spiralfamilyimplants.JMaxillofacOralSurg.8(4):334–339.•DanzaM,ZollinoI,ParacchiniL,VozzaI,GuidiR,CarinciF.3Dfiniteelementanalysiscomparingstandardandreverseconicalneckimplants:Boneplatformswitching.EDIJournal.2010;2:334–339.•DanzaM,QuarantaA,CarinciF,ParacchiniL,PompaG,VozzaI.BiomechanicalevaluationofdentalimplantsinD1andD4bonebyFiniteElementAnalysis.MinervaStomatol.2010;59(6):305–13.•DanzaM,ParacchiniL,CarinciF.Analisiaglielementifinitiperladefinizionedelladistribuzionedeglistressmeccanicinegliimpianti.DentalCadmos.2012;80(10):598–602.•MarrelliM,MalettaC,InchingoloF,AlfanoM,TatulloM.Three-pointbendingtestsofzirconiacore/veneerceramicsfordentalrestorations.IntJDent.2013;2013:831976.doi:10.1155/2013/831976.•InchingoloF,TatulloM,AbenavoliFM,MarrelliM,InchingoloAD,PalladinoA,InchingoloAM,DipalmaG.Oralpiercingandoraldiseases:ashorttimeretrospectivestudy.IntJMedSci.2011;8(8):649–52.•PaduanoF,MarrelliM,WhiteLJ,ShakesheffKM,TatulloM.OdontogenicDifferentiationofHumanDentalPulpStemCellsonHydrogelScaffoldsDerivedfromDecellularizedBoneExtracellularMatrixandCollagenTypeI.PLoSOne.2016Feb16;11(2):e0148225.doi:10.1371/journal.pone.0148225.•MarrelliM,FalisiG,ApicellaA,ApicellaD,AmanteaM,CieloA,BonanomeL,PalmieriF,SantacroceL,GianniniS,DiFabrizioE,RastelliC,GargariM,CudaG,PaduanoF,TatulloM.Behaviourofdentalpulpstemcellsondifferenttypesofinnovativemesoporousandnanoporoussiliconscaffoldswithdifferentfunctionalizationsofthesurfaces.JBiolRegulHomeostAgents.2015Oct–Dec;29(4):991–7.•TatulloM,MarrelliM,FalisiG,RastelliC,PalmieriF,GargariM,ZavanB,PaduanoF,BenagianoV.Mechanicalinfluenceoftissuecultureplatesandextracellularmatrixonmesenchymalstemcellbehavior:Atopicalreview.IntJImmunopatholPharmacol.2016Mar;29(1):3–8.doi:10.1177/0394632015617951Review.•InchingoloF,TatulloM,MarrelliM,InchingoloAM,InchingoloAD,DipalmaG,FlaceP,GirolamoF,TarulloA,LainoL,SabatiniR,AbbinanteA,CagianoR.Regenerativesurgeryperformedwithplatelet-richplasmausedinsinusliftelevationbeforedentalimplantsurgery:anusefulaidinhealingandregenerationofbonetissue.EurRevMedPharmacolSci.2012Sep;16(9):1222–6.•MarrelliM,TatulloM.InfluenceofPRFinthehealingofboneandgingivaltissues.Clinicalandhistologicalevaluations.EurRevMedPharmacolSci.2013Jul;17(14):1958–62.•InchingoloF,TatulloM,PacificiA,GargariM,InchingoloAD,InchingoloAM,DipalmaG,MarrelliM,AbenavoliFM,PacificiL.Useofdermal-fatgraftsinthepost-oncologicalreconstructivesurgeryofatrophiesinthezygomaticregion:clinicalevaluationsinthepatientsundergonetopreviousradiationtherapy.HeadFaceMed.2012Dec5;8:33.doi:10.1186/1746-160X-8-33.Review.•GargariM,PreteV,PujiaA,CerusoFM.Full-archmaxillaryrehabilitationfixedon6implants.OralImplantol(Rome).2013Jul15;6(1):1–4.•CarinciF,BrunelliG,FrancoM,ViscioniA,RigoL,GuidiR,StrohmengerL.Aretrospectivestudyon287implantsinstalledinresorbedmaxillaegraftedwithfreshfrozenallogenousbone.ClinImplantDentRelatRes.2010Jun1;12(2):91–8.•ScaranoA,MurmuraG,CarinciF,LauritanoD.Immediatelyloadedsmall-diameterdentalimplants:Evaluationofretention,stabilityandcomfortfortheedentulouspatient.EuropeanJournalofInflammation.2012;10(1):19–23.•FanaliS,CarinciF,ZollinoI,BrugnatiC,LauritanoD.One-pieceimplantsinstalledinrestoredmandible:Aretrospectivestudy.EuropeanJournalofInflammation.2012;10(1):37–41.•AndreasiBassiM,AndrisaniC,LicoS,OrmanierZ,OttriaL,GargariM.Guidedboneregenerationviaapreformedtitaniumfoil:Clinical,histologicalandhistomorphometricoutcomeofacaseseries.OralImplantol(Rome).2016Oct–Dec;9(4):164–174.

Scientific bibliography

Page 47: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for

4343UNIVERSE |

SWITZERLAND GERMANY

SPAIN

NORWAY

UNITED KINGDOM

EGYPT

GREECE

ITALY

POLAND

VIETNAMUNITED ARAB EMIRATES

SAUDI ARABIA

TAIWAN

ROMANIA

IRAN

QATARKUWAIT

IRAQSYRIA

NORTH AMERICA TURKEY

Contacts

IMLSA

Administrativeandoperationallocation:ViaMoree,16-IngressoB6850Mendrisio(Switzerland)Tel:+41(0)[email protected]

COMEANDVISITUSYouaremostwelcometocomevisitusonaguidedtourofourCompany.Donothesitatetocontactusforadate.

Distancebycarfromairports:•LuganoAgno(LUG)-Switzerland>22km-25min•MilanMalpensa(MXP)-Italy>57km-45min•MilanLinate(LIN)-Italy>72km-60min•MilanOrioalSerio(BGY)Italy>102km-90min

Page 48: UNIVERSE Catalogue...2 UNIVERSE Best performance in the cases: • any bone density • post extraction • delayed loading • immediate loading UNIVERSE SYSTEM Single platform for