Universal Chassis System UCS 1000

User Manual

Page 2: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance
Page 3: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 i

CAUTION!

This product may contain a laser diode operating at a wavelength of 1300nm - 1600nm. Use of optical instruments (e.g., collimating optics) with this product may increase eye hazard. Use of controls or adjustments, or performing procedures other than those specified herein may result in hazardous radiation exposure.

Under normal conditions, the radiation levels emitted by this product are under Class 1 limits in 21 CFR Chapter 1, Subchapter J.

ATTENCION! Cet équipement peut avoir une diode laser émettant à des longueurs d'onde allant de 1300nm à 1600nm. L'utilisation d'instruments optiques (par exemple : un collimateur optique) avec cet équipement peut s'avèrer dangereuse pour les yeux. Procéder à des contrôles, des ajustements ou toute procédure autre que celles décrites ci-après peut provoquer une exposition dangereuse à des radiations.

Sous des conditions normales, le niveau des radiations émises par cet équipement est en dessous des limites prescrites dans CFR21, chapitre 1, sous chapitre J.

NOTICE!

This device contains static sensitive components. It should be handled only with proper ElectroStatic Discharge (ESD) grounding procedures.

NOTE! Cet équipement contient des composants sensibles aux décharges électro-statiques. Il doit absolument être manipulé en respectant les règles de mise à la terre afin de prévenir de telles décharges.

Page 4: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 ii

NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for the proper installation, operation and/or maintenance of Canoga Perkins equipment. The drawings, specifications and information contained in this document are the property of Canoga Perkins and any unauthorized use or disclosure of such drawings, specifications and information is prohibited.

Canoga Perkins reserves the right to change or update the contents of this manual and to change the specifications of its products at any time without prior notification. Every effort has been made to keep the information in this document current and accurate as of the date of publication or revision. However, no guarantee is given or implied that the document is error free or that is accurate with regard to any specification.

Canoga Perkins Corporation 20600 Prairie Street

Chatsworth, California 91311-6008 Business Phone: (818) 718-6300

(Monday - Friday 7 a.m. - 5 p.m. Pacific Time) FAX: (818) 718-6312 (24hrs.) Web Site: www.canoga.com Email: [email protected]

Copyright© 2000 - 2005 Canoga Perkins Corporation All Rights Reserved

EdgeAccess®

Universal Chassis System Model UCS 1000

User Manual Product Number 6912200

Rev. G 01/2008 To reference Technical Advisories and Product Release Notes, go to Canoga Perkins'

website: http://www.canoga.com

Page 5: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 iii

Table of Contents Chapter 1 Introduction............................................................................................1-1

Chapter 2 Installing and Setting Up the Chassis ..................................................2-1

Chapter 3 Specifications..........................................................................................3-1 Physical Specifications........................................................................................................................3-1 Regulatory Compliance .......................................................................................................................3-2 Appendix A Warranty Information .....................................................................A-1

List of Figures Figure 1. Populated UCS 1000...........................................................................................................1-1 Figure 2. Chassis and Signal Ground Options....................................................................................2-1 Figure 3. Mounting Bracket on Chassis .............................................................................................2-2 Figure 4. Chassis Backplane and SW1, ID Switch.............................................................................2-3 Figure 4. DC Power Supply Detail.....................................................................................................2-4

List of Tables Table 1. Power Supply(s) and Maximum Number of Modules..........................................................1-2 Table 2. SW1, Chassis ID Switch ......................................................................................................2-3 Table 3. Power Supply LEDs .............................................................................................................2-5

Page 6: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 iv

Page 7: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 1-1

Chapter 1 Introduction

The Model 1000 Universal Chassis System (UCS) Chassis houses and supplies power to Canoga Perkins application modules. It accommodates modules that are 5U high and the Bus Access Modules (BAMs) or Management Access Modules (MAMs) that house and supply power to application modules that are 2U high.

Figure 1 shows some of the main Chassis components:

• The optional Domain Management Module (DMM) provides domain management • The optional Chassis Management Module (CIM) provides alarm relays and management for

multiple chassis in the domain • Individual application modules provide various network and transmission functions • AC and DC power supply options provide power to the backplane and application modules • An ESD grounding strap connector on the front of each power supply connects through the

chassis to Earth Ground.

Figure 1. Populated UCS 1000

The power supply options will determine how modules can be installed in each chassis. An AC power supply requires two slots; up to two DC power supplies require one slot. Table 1 shows maximum number of modules for each combination of power supplies.

Page 8: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 1-2

Table 1. Power Supply(s) and Maximum Number of Modules

AC Power Supplies

DC Power Supplies

Allows This Many Modules

None 1 or 2 15 1 None 14 1 1 13 2 None 12

By itself, the chassis cannot generate a power failure alarm. If you install a CIM, which includes alarm circuitry and connectors, you can connect an external device to the CIM in order to provide alarm information to a person or an environment away from the chassis. For details, see the Model 1200 Chassis Interconnect Module User Manual.

Page 9: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 2-1

Chapter 2 Installing and Setting Up the Chassis

This section describes how to set up the chassis, including power supply options, mounting, cabling, and powering up the chassis.

Caution: Equipment intended only for installation in a RESTRICTED ACCESS LOCATION accessible only to electrically skilled persons and electrically instructed persons with the proper authorization.

1. Plan the installation, considering these characteristics:

• Place the chassis within 7 ft. (2.134 m) of the power source. • Plan to use one or more of these locations for the connection to Earth Ground:

• The bonding lug on the rear of the chassis, near the bottom • The grounding prong on the AC power cord • The ground side of the -48 VDC terminal strip • The mounting hardware for the rack, if the rack is tied to Earth Ground

• Place the chassis adjacent to other Canoga Perkins or related equipment. • Allow room for the cable management bracket(s) that channel the cables, allowing slack in the

cables and providing a surface for securing with a tie-wrap. • Leave at least a 1U space between the chassis any other equipment for adequate ventilation; a

positive airflow cabinet is recommended. If the environment has little air flow or the chassis and other equipment are closely spaced or heavily loaded, use the optional fan tray to ensure adequate cooling. For details, contact Canoga Perkins Technical Support.

2. Unpack the chassis and inspect all components. Save the shipping carton and packing materials in case you need to return the equipment to the manufacturer. Appendix A provides information for Return Material Authorization (RMA).

3. Set the chassis and signal ground option located on the rear of the chassis, near the top. See Figure 2.

• To isolate the grounds for the chassis and the signal, screw the shorting plug into CS_GND/SIG_GND ISOLATED.

• To connect the grounds for the chassis and the signal, screw the shorting plug into CS_GND/SIG_GND CONNECTED.

Figure 2. Chassis and Signal Ground Options

Page 10: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 2-2

4. To connect Earth Ground to the bonding lug on the rear of the chassis, near the bottom, move the chassis adjacent to the installation area, then plug the Earth Ground wire into the bonding lug.

5. You can mount the chassis in a standard 19-inch relay rack, in a 23-inch rack using optional brackets, or place it on a flat, secure surface.

• To mount the chassis in a 19-inch rack, position the chassis in the rack, then attach the bracket to the rack with four screws.

• To mount the chassis in a 23-inch rack, replace the standard bracket with the optional mounting bracket, then attach that bracket to the rack with four screws; see Figure 3.

• To place the chassis on a flat, secure surface, turn the chassis upside down, mount the self-adhesive feet at the four corners of the bottom for the chassis, then turn the chassis right-side up. Keep a space around the chassis to allow airflow.

Three screws mount thebracket on the chassis

Figure 3. Mounting Bracket on Chassis

If the system includes two or more chassis that are connected through a CIM in each chassis, each chassis must be set to a unique ID number.

6. Locate SW1 inside the chassis at the upper left of the backplane; see Figure 4.

Caution: Make sure that the chassis power is off or disconnected. Use a non-conductive device to set SW1.

7. Set SW1 to the ID number for this chassis according to the information in Table 2.

Page 11: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 2-3

Figure 4. Chassis Backplane and SW1, ID Switch

Table 2. SW1, Chassis ID Switch

Chassis ID CID0 CID1 CID2

1 Closed Closed Closed 2 Open Closed Closed 3 Closed Open Closed 4 Open Open Closed 5 Closed Closed Open 6 Open Closed Open 7 Closed Open Open 8 Open Open Open

8. Set SW1, CH-DCPS, to match the primary power supply in the chassis. See Figure 4.

• For DC Power, set SW1, CH-DCPS to Open. • For AC Power, set SW1, CH-DCPS to Closed.

Page 12: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 2-4

If the chassis uses DC power, it requires a bracket in the end slot at the right side of the chassis. Install the primary DC supply in the top slot in the bracket and a redundant DC supply in the lower slot in the bracket. If the chassis includes a redundant AC power supply, install it in the next slot to the left. See Figure 1; it shows a DC power supply with a secondary AC supply.

If the chassis uses only AC power, install the primary AC supply in the end slot at the right side of the chassis. If the chassis includes a redundant AC power supply, install it in the next slot to the left...

9. To install a power supply, turn the power switch off and unplug any power cords or cables.

10. Slide the power supply firmly into the slot and tighten the captive Philips screws. to secure it.

Caution: In a redundant DC configuration, both DC sources must have the same ground potential.

11. Make sure the external power source is off, then connect the power for your power supply.

• For an AC supply, plug in the power cord. • For a DC supply, attach the GND and -VDC power cables to the screw terminal and re-install

the protective cover. See Figure 4.

Figure 4. DC Power Supply Detail

For details about installing the optional CIM and DMM, see the user manuals for the CIM and DMM.

12. Install the optional CIM in the bottom position in slot 0. See Figure 1.

13. Install the optional DMM the top position in slot 0. See Figure 1.

14. If the chassis does not include a CIM or DMM, install cover(s) on the unused slots.

15. Turn on the chassis power supply(s).

Note: The DC power-up delay may be up to eight seconds.

16. Check the LEDs on the power supply(s). Table 3 lists the LEDs and their meanings.

Page 13: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 2-5

Table 3. Power Supply LEDs

LED Color Description

DC Power Off No power Amber Soft start delay Green Normal operationAC Power Off No power Green Normal operation

The chassis is ready for installing the system modules. All modules are hot-swappable and can be inserted or removed at any time without affecting other modules in the chassis.

Page 14: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 2-6

Page 15: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 3-1

Chapter 3 Specifications

Physical Specifications Dimensions Chassis 8.75" H x 19" W x 11.75" D (222 mm x 482 mm x 264 mm) AC Power Supply 8.5" H x 1.7" W x 11.5" D (216 mm x 43 mm x 292 mm) Weight Chassis, unpopulated 12 lb. (5.45 kg) AC Power Supply 5 lb. (2.27 kg) DC Power Supply 1 lb. (0.45 kg) Mounting 19-inch rack

23-inch rack (with optional brackets) Operating Temperature 0-40°C with convection cooling, 0-50°C with fan tray Humidity Up to 95% (non-condensing) Power AC 150 W, 90 to 264 VAC @ 2 A max 50/60 Hz input

Front panel switch rated at 4 A continuous and 5 A up to 25 sec DC 150 W, -36 to -58 VDC @ 3 A max input

Front panel switch rated at 5A Total power consumption 150 W, max Backplane -36 to -58 VDC input, 180 mA, max, per slot Redundancy Optional, AC/AC, DC/DC or AC/DC Fan -48 VDC, cooling fan power connector located on the CIM

Caution: Equipment intended only for installation in a RESTRICTED ACCESS LOCATION accessible only to electrically skilled persons and electrically instructed persons with the proper authorization.

Page 16: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 3-2

Regulatory Compliance • ETL, cETL (UL 60950/CAN/CSA-C22.2 No.60950, EN/IEC 60950) IEC 60825-1 • FCC Part 15B/IC-003/VCCI Class A • C-Tick (AS/NZS 3548) • EN 55022 Class A • EN 61000-3-2, EN 61000-3-3 • EN 50024 • FCC Part 68/IC CS-03/TS-016 • CTR 12, CTR 13, NTR 4 • R&TTE Directive (EN 300 386) • NEBS Level 3 • CE Mark

Page 17: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

EdgeAccess Universal Chassis System

UCS 1000 A-1

Appendix A Warranty Information Current Warranty information is available on-line in the Client Login Area of the Canoga Perkins web site (www.canoga.com) or by contacting Technical Support at 800-360-6642 (voice) or [email protected] (email).

Page 18: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance
Page 19: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance
Page 20: Universal Chassis System UCS 1000 User Manual - Canogaproduct.canoga.com/media/manual/6912200G_MAN_UCS1000.pdf · a guide for the proper installation, operation and/or maintenance

CANOGA PERKINS CORPORATION

20600 Prairie Street

Chatsworth, California 91311-6008 USA Phone: (818) 718-6300 FAX: (818) 718-6312

Web Site: www.canoga.com Email: [email protected]