Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
>10h Operation with Li-Ion Battery Pack
Smart Autozero without Removal the Probe
CO Dilution up to 10%
Stores up to 250 Complete Analysis with Customer Name and Address
Graphic Display with Menu and Zoom Feature
USB & RS232 interface with Window Software
Made in Italy
The most powerful and advanced palmtop analyser: up to 6 sensors!
10 INSTRUMENTS IN 1:
Combustion Flue Gas Analyser
NO/NOx Emissions
SO2 Emissions
Draft & Differential Pressure Meter
2 Channel Differential Thermometer
Ambient CO Monitor (Room Test)
Gas Network Leak Tightness Tester
Gas Leak Detector
Ionization Flame Tester
Temperature & Humidity Meter
Built-in Impact Printer (Not Thermal!)
Advanced Combustion Flue Gas Analyser
세일국제무역 • Tel. 02-837-6974 • Fax. 02-859-2059 • www.eurotron.co.kr
UniGas 4000+ Portable, Flue Gas Analysis
Advanced Combustion • Flue Gas Analyser"Excellence in measurements"
O2 CO CO% CO2 NO NO2 NOx SO2 H2T-Air(℃)
T-Gas(℃)
Combustion Efficiency(ETA)
Excess air(Lambda)
Pressure(Pa)
CO/CO2ratio
Gas LeakDetector
T+RH%Probe
Water Trip Kit
Gas Sampling Hose
Heated Probe
CxHy
UNIGAS 4000 PLUS 1 / 6
UniGas 4000+ FLUE GASANALYSERS
Instrument design
세일국제무역 • Tel. 02-837-6974 • Fax. 02-859-2059 • www.eurotron.co.kr
"Excellence in measurements"
Magnet case
ConnectionUSB Cable Connection
T+RH(%) ProbeGas Leck /
Natural Gas ProbeConnectionAC Power /
Charging Adapter
LCD Display
Pressure / flowmeasurement
Cursor keys(Up/Down/Right/
Left/Scroll)
Water Trap Kit
Gas Sampling Hose
Line Filter
UNIGAS 4000 PLUS 2 / 6
The UniGas 4000+ provides the latest tecnology in flue gas analysis. One instrument with many features:
P up to 6 gas sensors; P draft, gauge and differential pressure measurements;
P autozero valve for quick start-up P searching for presence and location of gas leaks;
P CO sensor with automatic protection; P operator safety with ambient CO continuous monitoring;
P built-in impact printer; P ambient temperature and relative humidity measurements.
P water, air and surface temperature measurements; P IRDA output for Pocket PC data transfer.
Easy replaceable gas sensors CO sensor dilution
UniGas 4000+ uses extended life, low maintenance sensors An automatic device protect the CO sensor in presence of high
replaceable by the user. CO level. The measuring range will increase up to 10% CO.
Advanced Diagnostic Autozero valve for quick start-up
Built-in flow meter with internal leak test. Diagnostic errors on You can install the probe in the stack immediately during the
sensor with current indication. autozero. The instrument will be ready in less then 60 seconds.
Standard Report of Calibration Li-Ion Rechargeable battery
Each instrument is factory calibrated and certified against Lithium Ion rechargeable batteries provide longer field use free
Eurotron Standard to ensure traceability, and shipped with a from memory effect and total discharge. Flue gas analyser and
Report of Calibration. internal printer is powered by a unique battery pack.
Charger is supplied as standard.
Keyboard & Display
Text, menu, and keyboard available in most common languages Multi Fuel selection
(not icons) for simple and intuitive operations. UniGas 4000+ provides up to 10 fuels for calculating combustion
Engineering units are selectable by keyboard. The large backlight values.
graphic LCD can display 3, 6 or 12 values per page (ZOOM function) Most used fuels for your country are preloaded from factory.
or with bargraph format. Others fuels can be added using GasConfig PC software.
Built-in impact printer Pressure/Draft input
The instrument has an optional internal and rugged printer. It uses a Differential pressure input to verify: low pressure, draft, gas pipework
low cost common roll of paper. Certainly more readable, long time leak with pressure decay programme, pressure in gas pipework,
and heat resistant than the thermal printout on chemical paper. pressure in combustion chamber, DP on filters and fan, pressure
switches calibration.
Smoke index
Smoke index measurement is performed by using the optional Gas sampling probe
external hand pump. The results can be stored in the internal Flue gas sampling probes, with different lengths and shapes, are
memory and printed on the report. available to match each specific requirement. The sampling probe is
connected to the instrument with a single or dual hose through a
Ambient CO safety monitoring Room Test (BS7967) water trap and a suspended particle filter.
A procedure can be selected to monitor the CO in ambient air using
the internal sensors. An internal program allows the CO max Combustion air temperature probe
measurement in atmospheric boiler room test with 15 values logging. A remote Pt100 probe is available for remote combustion air
An external optional probe is also available for continuous temperature measurement. This probe is strongly recommended
surveillance of the ambient and operator safety. Both acoustic and mainly in forced air boiler to obtain an accurate efficiency
visual alarm are available. measurement.
세일국제무역 • Tel. 02-837-6974 • Fax. 02-859-2059 • www.eurotron.co.kr
UniGas 4000+ FLUE GASANALYSERS
One Instrument with Many Functions
"Excellence in measurements"
UNIGAS 4000 PLUS 3 / 6
Gas pipework leak test Ionization flame tester
To check gas pipework for the presence of leaks using a pressure Checks the ionization current in boiler flame control sensor.
decay program and the internal pressure sensor. The tightness
test procedure includes dual report (let by). Gas leak sniffer
IGE / UP / 1B compliant. The instrument can operate in two ways:
• An external probe is available to locate the position of a gas leak.
Flash memory This probe has a flexible stainless steel shaft to reach difficult
The flash memory allows the instrument to be configured by locations.
updating the UniGas firmware for any future legislation requirement • An internal optional sensor can be installed inside the analyser
or product performance upgrading to locate the position of a gas leak into the domestic pipe
network. The internal pump draws the air from ambient and
Proprietary designed trap makes the instrument more sensitive for micro-leaks.
Built-in protection for water suction.
External, to prevent risk of sensors damage.
Big water tank capacity for high condensing boiler. Small rubber
cup for easy water empty. Long life paper filter.
Type: palm-top combustion gas analyser. Print autonomy: up to 40 reports with full battery (typical).
Calibration: automatic calibration procedure at instrument Printed report header: 4 user programmable lines
switch-On.
Display: graphic black LCD with white lamp.
Self-diagnosis: Sensors efficiency test with display diagnostic
messages. Flue gas probes: stainless steel shaft with incorporated temperature
sensor.
Fuel types: Up to 10 selectable from keyboard (most common
preprogrammed). Memory: up to 250 full analysis data structured by boilers (Tags).
Power supply: High capacity Ni-MH rechargeable battery pack / Serial communication: standard USB serial interface.
external battery charger.
Operating temperature: from -40°C to +70°C
Charging time: 3h at 90% with instrument Off.
Storage temperature: from -40 to +80°C (3 months maximum at
Battery life: 10 hours (typical) continuous use (without printing & temperatures exceeding the operational limits).
backlit).
Dimensions: 115x90x330 mm
Printer: Internal impact type 24 columns with 58 mm paper roll.
Weight: 900 g nett. (including battery and printer).
Printer power supply: from the analyser battery pack.
UniGas 4000+ FLUE GASANALYSERS
One Instrument with Many Functions
Technical Specifications
세일국제무역 • Tel. 02-837-6974 • Fax. 02-859-2059 • www.eurotron.co.kr
"Excellence in measurements"
Gas sniffer probe
UNIGAS 4000 PLUS 4 / 6
UniGas 4000+ can store 250 readings structured by boilers and customers.
Using the optional DBGas 2004 WindowsTM software package, you can organize
and manage your inspection and maintenance activity.
DBGas 2004 software package includes TM GasConfig WindowsTM software.
Using the software you can modify the configuration of the instrument.
Pa Probe Water Trap
External 200Pa probe for natural
boiler draft measurements,
UNI 10845 compliant
Resolution: 0.1 Pa
Precision:
±0.5 Pa (from -10 to +10 Pa);
± 3 Pa otherwise.
Supplied with certificate of calibration.
ABS rigid carrying case Compact rigid carrying case
(TGD - Temperature, Gas, Draft) Differential pressure probe and
sampling probe burner hose kit
180mm, 300mm, 750mm,
1000mm, 1500mm
Manual pump for smoke index Pt100
measurements remote air sensor with cone
Ambient T+RH% probe Standard Gas Sampling Hose
Ambient CO probe Wanted length various
Gas sniffer probe
Heated Gas Sampling Probe Standard Gas Sampling Extension Hose
Length 300mm, 750mm, (max. 100m)
1000mm, 1500 mm
DBGas 2004 - Boiler Test & Customer Database Manager
UniGas 4000+ FLUE GASANALYSERS
Accessories for UniGas 4000+
세일국제무역 • Tel. 02-837-6974 • Fax. 02-859-2059 • www.eurotron.co.kr
USB standard interface
Patent pending
Rubber Cup to Empty
Line Filter
"Excellence in measurements"
UNIGAS 4000 PLUS 5 / 6
Parameter Range Unit Accuracy Res. Principle
O2 0…25 % ±0.1% vol. 0.1 % Electrochemical
CO 0...20,000 ppm ±1 ppm < 400 ppm 1 ppm Electrochemical
±0.2% rdg up to 4000 ppm
CO (H2 compensated) 0…10,000 ppm ±0.5% rdg elsewhere 1 ppm Electrochemical
CO % 0...10 % ±0.5% rdg up to FS 0.01 % Electrochemical
CO2 0...100 % 0.1 % Calculated
NO 0...4,000 ppm ±1 ppm <125 ppm 1 ppm Electrochemical
±0.2% rdg up to 4000 ppm
NO2 0...1,000 ppm <40 ppm = ±1 ppm 1 ppm Electrochemical
up to 500 ppm = ±0.5%
NOx 0…5,000 ppm Calculated
SO2 0…5,000 ppm ±0.2% rdg up to 5000 ppm 1 ppm Electrochemical
H2 0...2,000 ppm ±0 .2% rdg f.s 1 ppm Electrochemical
CxHy (CH4) 0...5.00% Vol. % ±0.5% rdg. 0.01% Pellistor
Tgas - 40...1200 ℃ ±(0.2% + 0.3℃) 0.1℃ TC K
Tflow - 40...100 ℃ ±(0.2% + 0.3℃) 0.1℃ TC K
Treturn - 40...100 ℃ ±(0.2% + 0.3℃) 0.1℃ TC K
Pressure -200...200 mbar ±0.2 mbar <50 mbar 0.1 mbar Piezo
±0.1% rdg. >50 mbar
Draft ±40.00 hPa ±0.01 hPa < 300 Pa 0.01 hPa Piezo
±0.1% rdg. > 300 Pa
Excess air 1.00...infinity or 0 - 250% 0.01 Calculated
Efficiency 1...120 % (also for condensing boilers 0.1 % Calculated
with automatic detection)
All emission measurements can be displayed with reference to a programmable O2 value.
Accuracy limits are stated as % of reading. An additional ±1 digit error has to be considered.
The stated pressure relative accuracy is valid only after the zero procedure.
3 Measuring reading can be directly converted from °C to °F, ppm to mg/Nm and from hPa to mmH2O, mbar, inH2O.
세일국제무역 • Tel. 02-837-6974 • Fax. 02-859-2059 • www.eurotron.co.kr
UniGas 4000+ FLUE GASANALYSERS
Gas measured values
"Excellence in measurements"
UNIGAS 4000 PLUS 6 / 6