UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.

UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Embed Size (px)

Citation preview

Page 1: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS

Maya Murshak – Merit Laboratories, Inc.

Page 2: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Why are we having this class?

•Understand a “Level I” report.

• Analytical results

•Define quality in the laboratory and how it is

represented in a “Level II” report.

• Batch quality control summary

•Influences of sampling on final results

Page 3: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

What is Quality?

•Quality Assurance

•Defined as everything done with respect to producing reliable data.

•Quality Control

•Defined as a single step or procedure to evaluate a process or test

Page 4: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Why Quality?

•Recognize, quantitate, and minimize errors.

•Describe the accuracy and precision of the data.

•Assess the legality of the reported results, i.e., defensible in the US court of law.

Page 5: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Certifications, Audits and PE Programs

•Certifications at the federal, state and client level.

•Most certifications have audits

•Most certifications have PE samples•Double blind samples that we

analyzed without knowing the answers.

•Bi-annual PE samples.

Page 6: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

NELAP

•National Environmental Laboratory Accreditation Program

•Non government program sponsored by individual states and the EPA.

•On site audit every 2 years

•Bi-annual PE studies

Page 7: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Quality starts with field sampling• A majority of all errors in environmental analysis result

from incorrect sampling.

• Factors• Safety• Obtaining a representative sample• Preventing contamination• Legal documentation• Protecting the sample from changing prior to analysis

(preservation)

• Detailed standard operating procedures• Typically not covered by audits or PE programs.

• Detailed record keeping• Field records• Chain of Custody

Page 8: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Field Quality Control

•Field blanks

•Trip blanks

•Equipment blanks

•Preservatives

•Ice

•Bottles

•Chemicals

Page 9: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Custody

• Important to document where and who has the sample at all times.

• Chain of Custody - Legal document • Description of the sample• Who collected, what container, where and when.• Requested tests• Signature and dates/times when the sample was

passed from person to person• Included with the final report.

• Internal Custody• Often provided by LIMS system• Custody of each bottle – NELAC regulation

Page 10: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Laboratory Quality Control

•Quality Control designed to check four general areas.• Calibration of instrument• Process is contamination free• Process is efficient and accurate• Matrix effects

Page 11: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

GM Level I Report

•Sample information

•Parameter details

•Custody documents

Page 12: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Example Report

Sam

ple

In

form

atio

nP

aram

eter

D

etai

ls

Page 13: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Sample Information

•Project ID

•Sample ID

•Field Personnel

•Date & Time collected

•Date & time Received

•Laboratory ID

Page 14: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Correct Methods

•Correct method depends on regulatory program• NPDES/IPP - 40 CFR 136• Waste/RCRA - SW-846• Monitoring/Landfill - SW-846 or 40 CFR 136• Drinking Water

•Alternate Test Procedures• NPDES/IPP • Parameters not listed in 40 CFR 136 • Michigan in EPA Region 5

Page 15: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

DETECTION LIMITS

•MDL - Method Detection Limit

• The minimum level of an analyte that can be qualitatively identified with 99% confidence. (40 CFR Part 136, Appendix B)

•Reporting Limits

• The minimum level of an analyte that can be reasonably reported by the laboratory taking into consideration the sample matrix.

• PQL, LOQ

Page 16: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

QC ORGANIZATION - BATCHES

•Sample and QC data are grouped into batches

• A batch may be defined by sample count (e.g. 20)

• A batch may be defined by time elapsed (e.g. 12 hr.)

•Each batch has QC validating its samples

• Example: LCS, Blank, MS, MSD, Duplicate

•Types of batches:

• Preparation (e.g. digestion, extraction)

• Analytical (e.g. GC/MS, ICP/MS)

• Samples may belong to both types of batches

Page 17: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

EVALUATING QC - LEVEL II DATA

•Evaluate Preparation QC Items (as analyzed):• Method Blank• Laboratory Control Sample (LCS)• Matrix Spike (MS)• Duplicate and/or Matrix Spike Duplicate

(Dup, MSD)• Surrogates (for organic analyses)

•Instrument QC Items are not included

Page 18: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

SUMMARY OF QC INFLUENCES

|----------- Performance Impact -----------| |- QC Deliverable -|

QC Item InstrumentSample

Prep.SampleMatrix

FieldConditions II III

Calibration& Raw Data

LCS

MS

Dup/MSD MethodBlank

Field Blank

Page 19: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

EXAMPLE - MATRIX INTERFERENCE•Actual sample matrices may contain target and non-

target interferences that preclude the analysis of a sample in an undiluted state and result in elevated reporting limits.

Method Blank Sample Exhibiting Interference

PNAs abovecalibration range

Heavy Oil causing poorinternal standard recovery

Page 20: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

COURSE CONCLUSIONS• Different QC items are designed to characterize the various

cumulative effects contributing to data quality;

• The requested QC deliverable affects the scope and detail of QC items provided; and

• The sample matrix can often play a large role in the usefulness of the analytical results for their intended purpose.

|----------- Performance Impact -----------| |- QC Deliverable -|

QC Item InstrumentSamplePrep.

SampleMatrix

FieldConditions II III

Calibration& Raw Data

LCS

MS

Dup/MSD MethodBlank

Field Blank

Page 21: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

ABOUT THE PRESENTER

Maya Murshak

•Maya is the Quality Assurance and Technical Director for Merit Laboratories, Inc. and has been with the lab since it was started in 1987. She currently works primarily with laboratory certification, accreditation, data validation and project coordination. She also has over 15 years of practical laboratory experience based on her extensive analytical work with both GC and GC/MS systems. Maya is a Chemical Engineer, holding both B.S. and M.S. degrees from Michigan State University.

Page 22: UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc

Thank You