16
Ultrasound Phantoms

Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

Ultrasound Phantoms

Page 2: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

USA: www.kkamerica-inc.com WORLDWIDE: www.kyotokagaku.com

Contents

US-14a, US-14bUltrasound Neonatal

Head Phantoms>>P.01

US-9Ultrasound Guided

Breast Biopsy Phantom>>P.04

US-2Ultrasound Quality

Assurance Phantoms>>P.07

US-3Abdominal Intraoperative & Laparoscopic

Ultrasound Phantom "IOUSFAN">>P.08

US-1Ultrasound Examination

Training Phantom"ECHOZY">>P.02

US-11Scrotal Ultrasound Phantom

>>P.05

11347-210Introductory Ultrasound Training

Block "REAL VESSEL">>P.10

US-1BUltrasound Examination

Training Phantom "ABDFAN">>P.02

US-13Infant Hip Sonography

Training Phantom>>P.05

M43EUltrasound Compatible Lumbar

Puncture/Epidural Simulator>>P.08

Page 3: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

Tel: 1-310-325-8860 Fax: 1-310-325-8867

US-6Breast Ultrasound Examination

Phantom "BREASTFAN">>P.04

MW18Ultrasound-Guided PICC

Training Simulator>>P.10

US-4Breast Ultrasound QA

Phantom>>P.07

US-8Pediatric FAST/Acute Abdomen Phantom

>>P.06

M93CCVC Insertion Simulator III

>>P.09

US-10Female Pelvic

Ultrasound Phantom>>P.03

M93UBCVC Insertion Simulator II

>>P.09

US-7aFetus Ultrasound Examination

Phantom "SPACE FAN-ST">>P.03

US-5FAST/Acute Abdomen

Phantom "FAST/ER FAN">>P.06

Custom Orders and Future Phantoms

Kyoto Kagaku Phantomsfor Ultrasonography

>>P.11-12

Page 4: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

01

USA: www.kkamerica-inc.com WORLDWIDE: www.kyotokagaku.com

US-14a

US-14b

Ultrasound Neonatal Head Phantom “GEORGE” (Normal type)

Ultrasound Neonatal Head Phantom “JEAN” (Abnormal type)

Anatomy

Anatomy

Training SkillsScanning of brain anatomy in Sagittal (Angled Parasagittal), Coronal and Transverse planes via any fontanel.

SkullAnterior fontanel, Posterior fontanelCerebrumCerebellumBrain-stemLateral ventricleVentricleThird cerebroventricleFourth ventricleSeptum lucidum

Skull Anterior fontanel, Posterior fontanel Cerebrum Hypertrophied lateral ventricle

Head ultrasound is one of most difficult scanning skills, and trainees have few opportunities for training.This head model features an accurate depiction of a newborn’s cerebral anatomy, and facilitates a realistic user experience with its life-like soft touch.

This head phantom is designed to demonstrate abnormal anatomy, such as Hydrocephalus, in which the shape of the skull is altered due to intracranial pressure.

* Specifications are subject to change

World’s First Ultrasound Neonatal Head Phantom

World’s First Ultrasound Neonatal Head Phantomwith Hydrocephalus

Page 5: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

02

Tel: 1-310-325-8860 Fax: 1-310-325-8867

US-1

US-1B

Ultrasound Examination Training Phantom "ECHOZY"Ultrasound Examination Training Phantom "ABDFAN"

Features

Anatomy

Pathologies

Training SkillsBasics of abdominal sonography: - Cross sections and sonographic anatomy - Sonographic demonstration of each individual organ - Localization of hepatic Couinaud's segments

Liver(segmental anatomy, portal and hepatic venous systems, ligamentum teres and ligamentum venosum)Biliary tract(gallbladder, cystic duct, intrahepatic and extrahepatic bile ducts)Pancreas (pancreatic duct)Spleen / kidneys Detailed vascular structures (aorta, vena cava, celiac artery and its branches, portal vein and its branches, superior mesenteric vessels, renal vessels, and more.)

Hepatic lesions (cystic and solid)Gallbladder and bile duct stonesPancreatic tumors (one invading the portal vein)Splenic lesionsBoth kidney lesionsLeft adrenal tumor

Detailed hepatobiliary, pancreatic and other abdominal anatomyEight Couinaud's hepatic segments can be localized.ABDFAN has various simulated lesions to provide wider range in training.

1.2.3.

Set variations:US-1 (41900-010)"ECHOZY"

US-1 (41900-000)"ECHOZY" full set

US-1B (41900-030) "ABDFAN"

US-1B (41900-100)"ABDFAN" full set

1 ultrasound phantom "ECHOZY" 1 ultrasound phantom "ECHOZY" 1 ultrasound phantom "ABDFAN" 1 ultrasound phantom "ABDFAN" 1 set positioning pillows 1 anatomical model "ECHO-ZOU" 1 set positioning pillows 1 anatomical model "ECHO-ZOU" 1 storage case 1 set positioning pillows 1 tutorial manual (DVD) 1 set positioning pillows

1 storage case 1 storage case 1 tutorial manual (DVD) 1 storage case

Abdominal ultrasound phantom without pathologies

ABDFANECHOZY

Specifications:

Abdominal ultrasound phantom with pathologies

(ABDFAN only)

Junji Machi, MD, PhDUniversity of Hawaii at Manoa and Kuakini Medical Center

Dr. Hitoshi Asai, DirectorOsaka Kyoiku University, Health Administration CenterDr. Shigeru NakamuraNagayoshi General Hospital, Clinical Examination Department

Product SupervisionProduct Supervision

Page 6: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

03

USA: www.kkamerica-inc.com WORLDWIDE: www.kyotokagaku.com

US-7a US-10Fetus Ultrasound Examination Phantom"SPACE FAN-ST" Female Pelvic Ultrasound Phantom

FeaturesFeatures

Anatomies and Pathologies

Anatomies and Pathologies

Training Skills

Training Skills

Transvaginal and transabdominal screeningsLocalization of pathologies3D ultrasound imaging restructuring

Pathological unit- endometrial cancer, uterine fibroid, dermoid cyst of ovary, bleeding at Douglas pouch

Ectopic pregnancy unit- ectopic pregnancy in a fallopian tube, bleeding at Douglas pouch

Fetal size assessment: BPD, AD, AC and FLMeasurement of amniotic fluid volumeDetermination of fetus positionAssessment of each body part -Head: skull and brain -Spine and limbs -Cardiac chambers, blood vessels, and lungsAssessment of umbilical cord and placentaDetermination of sex (fetus is a male)

Uterus: amniotic fluid, placenta, umbilical cord, and a 23-week fetus (10.2 in)Fetus: skeletal structure, brain with septum lucidum, lateral ventricles and cerebellum, heart with four chambers, lungs, spleen, kidneys, aorta, UV, UA, and the external genital

The oval shape phantom abdomen can set in four different positions.

fetus demonstration model

Realistic pathology for transvaginal ultrasound training as well as transabdominal procedureExcellent ultrasound image qualityAnatomically correct and life-like imagesCompatible with any ultrasound machine2 kinds of exchangeable phantoms for differing pathologies

SPACE FAN-ST provides high quality training for routine second trimester screening.The oval shape phantom abdomen can be set in four different positions

1.

2.3.4.5.

1.

2.

Female pelvic phantom with 2 screening methodsFetus ultrasound phantom with a full skeletal structure

Charlotte Henningsen, MS, RT(R), RDMS, RVT, FSDMS, FAIUMChair & Professor - Sonography DepartmentAdventist University of Health Sciences

Kiyoko Kabeyama RN, RM, PhDProfessor Midwifery & Women’s Health, School of Human Health Science,Graduate School of Medicine, Kyoto UniversityHaruto Egawa, PhDNational Hospital Organization Kyoto Medical CenterDepartment of Obstetrics, Head Physician or Medical Director

Product SupervisionProduct Supervision

Set includes:1 lower torso manikin 1 ultrasound ectopic pregnancy unit1 ultrasound pathology unit 1 storage caseSize: 13.4 x 13 x 9.5 in.Set Variations:(US-10a) Female Pelvic Ultrasound Phantom (includes a normal unit, a ectopic pregnancy unit and a pathology unit)

Set Includes: Size:1 mother body torso 16 x 11.6 x 8.8 in.1 ultrasound pregnant uterus phantom1 fetus demonstration model1 storage case1 tutorial manual (DVD)

Specifications:Specifications:

Brain with Septum Lucidum,Lateral Ventricles and Cerebellum UV

Page 7: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

04

Tel: 1-310-325-8860 Fax: 1-310-325-8867

US-6 US-9Breast Ultrasound Examination Phantom"BREASTFAN"

Ultrasound GuidedBreast Biopsy Phantom

Features Features

Anatomies

Pathologies

Training Skills

Training Skills

Skills to scan full area of breast systematicallyVisualization of key anatomical landmarksTracking galactphoreVisualization and differentiation of typical pathologiesLocalization and measurement of cyst and tumors

Hand-eye coordination in ultrasound biopsyLocalization of targets under ultrasound guidanceSampling of target

Subcutaneous adipose, mammary gland, galactophore, Cooper’s ligament, retromammary adipose, costae, clavicle, pectoralis major, lung , and lymph nodes at axilla.

Cyst, mammary ductal ectasia, malignant tumor, benign tumor

State-of-the-art breast phantom with ultrasound anatomySkills required for ultrasound breast screening can be greatly advanced with practice.

Compatible for FNAB, CNB and mammotome biopsy with ultrasound guidanceColored targets embedded in three levelsRealistic representation of the mammary glandAn inexpensive and disposable phantom that provides many numbers of trials.The opaque phantom includes 2 types of targets; Hyperechoic and Hypoechoic.

1.2.

1.

2.3.4.

5.●

●●

Training in ultrasound breast cancer screening with detailed anatomy

Provides step by training in ultrasound guided breast biopsy

Tokiko Endo, MD, PhDDirector of Department of Advanced Diagnosis,Clinical Research Center,National Hospital Organization Nagoya Medical CenterDirector of Department of Radiology,National Hospital Organization Nagoya Medical Center

Product Supervision

Set Includes: Size:1 breast phantom 7.6 x 8.8 x 2.8 in.1 storage case1 tutorial manual (DVD)

Set Variations: Size:Duo set: (11387-000) transparent + opaque type 6.3 dia x 3.2 in.Transparent set: (11387-100) 1 pair of transparent typeOpaque set: (11387-200) 1 pair of opaque type)

Specifications: Specifications:

Cyst Malignant Tumor

Transparent

Opaque

Hand-eye coordination

Acquisition of skills in safe and reliable needle biopsy

Size of targets: 6 mm dia. and 10mm dia.Type of targets: Hyperechoic (blue)Number of targets: 12 pieces

Size of targets: 6 mm dia. and 10mm dia.Type of targets: Hyperechoic (blue), Hypoechoic (red)Number of targets: 12 pieces

Page 8: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

05

USA: www.kkamerica-inc.com WORLDWIDE: www.kyotokagaku.com

US-11 US-13Scrotal Ultrasound Phantom Infant HipSonography Training Phantom

Features

Features

Anatomies and Pathologies

Anatomies

Training Skills

Training Skills

Scrotal ultrasound screeningVisualization of testicular cancer

Excellent ultrasound image qualityNormal and pathological unit provides differing case typesExchangeable scrotal phantoms with easy cleaning

The two phantoms, normal and pathological, facil itate a thorough anatomical understanding as well as a clear visualization of scrotal pathologies.

1.2.3.

Excellent visualization of scrotal pathologies Best tool to teach Graf’s method

Charlotte Henningsen, MS, RT(R), RDMS, RVT, FSDMS, FAIUMChair & Professor - Sonography DepartmentAdventist University of Health Sciences

Univ. Prof., Prof. hc. Reinhard Graf, M.D.

Product Supervision

Product Supervision

Set includes:1 lower torso manikin 1 normal scrotal unit1 pathological scrotal unit 1 storage caseSize:13.4 x 13 x 9.5 in.

Set includes: Size:1 ultrasound infant phantom 21.6 x 9.8 x 5.1 in.1 instruction manual

Specifications:

Specifications:

1.

2.3.

4.5.

The market’s only training model for hip sonography on a full body manikin of 6-week-old infantBilateral hips for examinationKey landmarks that can be recognized under ultrasound in-clude: - chondro-osseous junction (bony part of femoral neck), - femoral head, synovial fold, joint capsule, labrum, - hyaline cartilage preformed acetabular roof, - bony part of acetabular roof, bony rim (check list I), - lower limb of os ilium, correct plane, labrum (check list II).Facilitate anatomical understandingThe full body manikin with movable arms allows training in supporting and changing the position of the infant.

Setting and preparation for hip sonographyChanging the position of the infantCommunication and interaction with the infant's guardian Correct positioning and use of the transducerRecognition of ultrasonic landmarks for hip sonography Visualization of standard, anterior and posterior planesInterpretation and morphological classification of the sonogram

Femoralhead

bony rim

(plane)

great trochanter

cartilage acetabular roof

labrum lower limb

ilium

Page 9: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

06

Tel: 1-310-325-8860 Fax: 1-310-325-8867

US-5 US-8FAST/Acute Abdomen Phantom"FAST/ER FAN"

PediatricFAST/Acute Abdomen Phantom

Features Features

Anatomies and Pathologies

Anatomies and Pathologies

Cardiac Tamponade

Pleural Hemorrhage

Right Upper Abdominal Bleeding Hydronephrosis

Pelvic BleedingAppendicitis

An innovative phantom for repetitive training of FAST as an adjunct to the ATLS primary surveyPathologies including cholecystitis, an aortic aneurysm, lesion on the colon

The phantom includes life-size 2-year-old thoracoabdominal organs, a bone structure, free fluid to learn FAST procedures and pathologies that are commonly seen in pediatrics.With this phantom, trainees can acquire skills in basics of pediatric abdominal ultrasound.

FAST/ER FAN provides training to detect the presence of free intraperitoneal or pericardial fluid in patients experiencing trauma.

This abdominal ultrasound phantom includes life-size anatomies of a 2 years old with internal hemorrhage and other conditions commonly found in acute pediatric patients.

1.

2.1.

2.

Best tool for workshops in emergency ultrasound The world’s first pediatric ultrasound torso phantom

Junji Machi, MD, PhDUniversity of Hawaii at Manoa and Kuakini Medical Center

Shunsuke Nosaka, MD, PhDDirector of RadiologyNational Medical Center for Children and Mothers

Product Supervision Product Supervision

Set includes:1 ultrasound phantom with storage case1 tutorial manual (DVD)Size:21 x 12 x 9 in.

Set includes: Size:1 ultrasound phantom 16 x 6 x 6 in.1 storage case1 tutorial manual (DVD)

Specifications:Specifications:

Page 10: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

07

USA: www.kkamerica-inc.com WORLDWIDE: www.kyotokagaku.com

US-4 US-2Breast Ultrasound QA Phantom UltrasoundQuality Assurance Phantoms

Ultrasound QA phantom for high precision imaging in the high frequency sonography around 10 MHz that is required in breast examination.For monthly basic quality check of ultrasound images, as well as longer term quality assurance to maintain consistency of the performance of scanners and transducers.

Mass targets block (contrast resolution)N-365 Multipurpose Phantom

N-060QA Phantom

N-211String Phantom

N-255Cyst Phantom

Mass targets block (contrast resolution)

Ensure highly detailed images to ensure reliable breast cancer examinations

Set includes: Phantom size:1 mass targets blocks mass targets block phantom size:

W7.2 x D3 x H4.4 in.dot targets block phantom size: W5.4 x D3 x H4.4 in.

1 dot targets blocks1 thermometer1 storage case

Specifications:

Cyst targetsGray scale targets

Set includes: Phantom size:1 phantom W7.6 x D8.8 x H2.8 in.1 storage case

Durable and stableUseful both for daily assessment and further research. Gray scale for evaluation, cyst targets with non-resonance cylinders, line targets for geometrical evaluation including close range (dead zone) resolution, axial and lateral resolution are prepared for scanning. The phantom is designed to allow scanning from all four side walls.

Specifications:

Gray scale

String target

Gray Scale

Page 11: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

08

Tel: 1-310-325-8860 Fax: 1-310-325-8867

US-3 M43EAbdominal Intraoperative & Laparoscopic Ultrasound Phantom"IOUSFAN"

Ultrasound CompatibleLumbar Puncture/Epidural Simulator

Ultrasound compatible puncture block is anatomically correct and offers realistic image of ultrasound. Both epidural space and subarachnoid space are accessible for training.

Innovative phantom simulating abdominal open intraoperativeand laparoscopic ultrasound examination

Ultrasonic anatomy and needle access trainingEffective training tool for abdominal intraopera-tive ultrasound examination

Set includes: Replacement parts:1 lumbar region model (11348-190) 1 ultrasound lumbar

puncture/epidural block1 ultrasound lumbar puncture/epidural block (11348-230) 1 ultrasound lumbar

region skin cover for M43E1 ultrasound lumbar region skin cover2 lumbar region support bases1 irrigator bag/ tube/ support base and syringe

Manikin Size:W13 x D8.3 x H11.8 in.

Set includes: Manikin Size:1 upper abdomen ultrasound phantom W12 x D15 x x H7 in.1 stomach ultrasound phantom1 phantom container1 tutorial manual (DVD)

Specifications:

Specifications:

FeaturesFeatures

AnatomyAnatomy

Training SkillsTraining SkillsUltrasound-guided lumbar punctureUltrasound-guided epidural anesthesiaCSF collection and CSF pressure measurement

Abdominal intraoperative ultrasound examinationLaparoscopic ultrasound examination

Lumbar spine (L2-L5) including spinous process and transverse processSpinal canal, epidural space

Liver(segmental anatomy, portal and hepatic venous systems,ligamentum teres and ligament venosum)Biliary tract(gallbladder, cystic duct, intrahepatic and extrahepaticbile ducts)Pancreas (pancreatic duct)Spleen / kidneysDetailed vascular structures(aorta, vena cava, celiac artery and its branches, portal vein and its branches, superior mesenteric vessels, renal vessels, etc.)

Ultrasonic landmarks of lumbar spine can be visualized.Skin cover allows marking with a pen.Both upright and lateral positions are possible for training.Translucent blocks allow users to see the needle pathway under direct vision.

Soft phantom materials allow realistic probe manipulation.Various simulated lesions including biliary stones and cysts,solid tumors (hypoechoic, hyperechoic and target-appearance)in the liver, pancreas, spleen and kidneysDetachable stomach and duodenum allows various scanningmethods of the bile duct and pancreas.

1.2.3.4.

1.2.

3.

Page 12: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

09

USA: www.kkamerica-inc.com WORLDWIDE: www.kyotokagaku.com

M93UB M93CCVC Insertion Simulator II CVC Insertion Simulator III

Great practice simulator for CVC catheter insertion with a variety of methods

CVC Insertion Simulator III provides training in a se-quence of procedural skills from the needle insertion to catheter placement, including Seldinger technique.

Set includes:1 male upper torso manikin 1 introductory ultrasound training block1 landmark puncture pad 1 skin for cannulation training1 ultrasound puncture pad 1 red coloring powder1 transparent anatomical block 1 blue coloring powderSize: 16 x 18 x 13 in.

Set includes:2 CVC placement pads 1 vein pipe2 artery tubes 1 instruction manual2 vein tubesSize: 16 x 18 x 13 in.

Specifications:Specifications:

Features Features

Training Skills

Training Skills

Anatomy

Ultrasound-guided CVCLandmark guided CVCUltrasound-guided venous accessPrevention of mechanical complications

Ultrasound-guided CVCLandmark guided CVCUltrasound-guided venous accessPrevention of mechanical complications

CVC Insertion Simulator II offers training in both landmark and ultrasound-guided central venous catheterization. Landmark puncture pad with anatomically correct vein bifurcations simulates mechanical complications including pneumothorax, mislodging and artery puncture.Introductory ultrasound training block to acquire basics of ultrasound guided venous access.Transparent anatomical block for anatomical understanding and guide wire manipulation.Both internal jugular and subclavian (axillary) veins are accessible.

1.

2.

3.

4.

5.

Masahiro Tanabe, M.D., Ph.D., Professor Director General Medical Education Center Chiba University School of MedicineKinya Sando, M.D., Ph.D., Professor Director Department of Human Dietetics Graduate School of Human Science Osaka Shoin Women’s UniversityMasanori Hoki, M.D., Ph.D., Professor Department of Human Dietetics Graduate School of Human Science Osaka Shoin Women’s UniversityJoho Tokumine, M.D.Ph.D., Department of Anesthesia, Kawatetsu Chiba Hospital

Product Supervision

Transparent Anatomical Block

Landmark puncture pad

Repeated insertion:

Both Landmark and ultrasound-guided CVC:

New Material

Mechanical complications, such as arterial puncture and pneumothorax can be simulated for training.

Realistic venous collapse

Improved frictionless tissue of the pad allows Seldinger technique and repeated insertion and removable of the catheter with less needle marks left on the surface of the pad.

Anatomically correct structure facilitates training in both landmark and ultrasound-guided CVC.

Close to human tissue material of the pad provides true-to-life sensation to the catheter.

1.

2.

3.

4.

5.Probe Skin

Carotid

Internal jugular vein

Internal jugular vein & carotid arterySubclavian vein & arterySuperior vena cavaRibsSternumLung

Page 13: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

10

Tel: 1-310-325-8860 Fax: 1-310-325-8867

MW18 11347-210

Ultrasound-GuidedPICC Training Simulator

Introductory Ultrasound Training Block"REAL VESSEL"

Comprehensive, hands-on training for PICC insertion Provides training in hands-eye coordination and basic skills in ultrasound-guided venous access.

Set includes:2 CVC placement pads 1 vein pipe2 artery tubes 1 instruction manual2 vein tubesSize: 16 x 18 x 13 in.

Set includes:1 male upper torso with the right arm 1 syringe2 PICC puncture pad 1 instruction manual10 simulated blood (swab type) 1 storage case1 jarSize: 15.7 x 5.9 x 23.7 in.Replacement part:(11348-010) 2 PICC puncture pads

Specifications:

Features

Features

Training Skills

Training Skills

Correct needle insertion, PICC, manipulation and catheter tip placementFinding a puncture site under ultrasound guidanceThe Seldinger techniqueTechnique for the peel-away sheathAdvancing of the cannula into the SVC

Visualization and localization of the vesselsTransducer manipulationBasics for ultrasound-guided vascular access

Excellent image quality and visualization of the needle tip for ultrasound guided venous accessMovable shoulder to demonstrate positioningRealistic flashback in needle provides confirmation for successful venous accessRibs and right clavicle provide anatomical understanding of correct PICC placementAnatomically correct bifurcation of the veinSimulation of cannula malposition

2 simulated vessel lines: straight and curve.Lines have slope to represent vessels with different depth.Vessel wall yields under pressure of a needle tip.

1.

2.3.

4.

5.6.

1.2.3.

Cannulation

This model provides training in full procedural skills from the needle insertion, manipulation of the PICC to the placement of the distal tip in the SVC. Both basilic and cephalic veins are accessible for different levels of challenges in cannulation. The replaceable puncture pad is ultrasound-compatible. Anatomically correct bifurcation of the vein provides realistic resistance on its outer walls and simulates complications such as catheter malpositioning.

US-9 Ultrasound GuidedBreast Biopsy Phantom

Training SkillsHand-eye coordination in ultrasound biopsyLocalization of targets under ultrasound guidanceSampling of target

Provides step by training in ultrasound guided breast biopsy

For more detail>> P.04

Set includes:REAL VESSEL Introductory ultrasound training block (a set of 2)

Page 14: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

USA: www.kkamerica-inc.com WORLDWIDE: www.kyotokagaku.com

Custom Orders and Future Phantoms

We believe in the importance of providing phantoms that meet your needs and listening to your voice to find a solution.

If you would like to suggest any additional features for our phantoms, please do not hesitate to contactKyoto Kagaku America Inc!Innovation is our tradition.

Bladder Ultrasound Phantom

Finger Joint Ultrasound Phantom

CT-Ultrasound Fusion QA Phantom

Fundamental Ultrasound Phantom

Research Model for Transcranial Doppler (TCD)

Let us know your thoughts

Have you found what you are looking for?

Cases

We take pride in offering a wide variety of high quality models, simulators and phantoms.Please do not hesitate to contactKyoto Kagaku America Inc!

Page 15: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

Tel: 1-310-325-8860 Fax: 1-310-325-8867

Kyoto Kagaku Phantoms for ultrasonography

7.5 MHz linear probe was applied on the old phantommade in 2004 on the front row, and new phantommade in 2012 was displayed on the back row.

Durable, stable with homogeneous granular background reflection with excellent and controllable echogenicities

Highter sonic velocity for detailed QA in high-frequency ultrasound.

Sonic velocity: 1434m/sec at 25 degrees CDensity: 0.954g/cmAttenuation rate: 0.57dB/cmMHz at 25 degrees CAcoustic impedance: 1.37 rayl at 25 degrees C

Mass targets block (contrast resolution) Dot targets block (spatial resolution)

Japanese patent No. 3650096

>> see also page 7

Natori H, Igarashi T, Arakawa M. Durable fine resolution test phantomfor diagnostic ultrasound systemECR 2013 Poster C-1765

Gray scale targets Cyst targets

"Durable fine resolution test phantom for diagnostic ultrasound system", H.Natori 2013

Materials for Ultrasound Phantoms

US-4 BreastUltrasound QA Phantom

15 degrees C 25 degrees C 35 degrees CSpeed of sound 1449.5 m/sec 1434.1 m/sec 1403.9 m/secAttenuation rate 0.58 dB/cmMHz 0.57 dB/cmMHz 0.55 dB/cmMHz

Page 16: Ultrasound Phantoms - Kyoto Kagaku America · Breast Biopsy Phantom >>P.04 US-2 Ultrasound Quality Assurance Phantoms >>P.07 ... The market’s only training model for hip sonography

09.2016

[email protected]

Kyoto Kagaku America Inc.

3109 Lomita Boulevard,Torrance, CA 90505-5108, USATEL: 1-310-325-8860FAX: 1-310-325-8867

North and South American regions

VisitOur Show room!