ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX – 6 Couplant : Greace
Equipment : 2.7/8” Lubricator x 8 ft Tag No. : CRS 0497-3-1/1 Description of Item
PartMaterial Thickness Minimal Wall Thickness
(mm)00 900 1800 2700
A 11.79 11.56 12.17 12.10 11.56B 11.80 11.74 11.97 12.18 11.74C 12.17 11.83 12.21 12.10 11.83
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
90°
0°
270°
180°
A CB
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX – 6 Couplant : Greace
Equipment : 3.1/2” Lubricator x 8 ft Tag No. : CRS 0497-5-1/1 Description of Item
PartMaterial Thickness Minimal Wall Thickness
(mm)00 900 1800 2700
A 16.63 16.58 16.85 16.50 16.50B 16.55 16.66 16.53 16.62 16.53C 16.52 16.42 16.57 16.49 16.42
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
90°
0°
270°
180°
A CB
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX – 6 Couplant : Greace
Equipment : 3.1/2” Lubricator x 8 ft Tag No. : CRS 0497-4-1/2 Description of Item
PartMaterial Thickness Minimal Wall Thickness
(mm)00 900 1800 2700
A 16.60 16.85 16.20 16.20 16.20B 16.95 16.69 16.03 16.05 16.03C 16.64 17.70 16.31 16.40 16.31
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
90°
0°
270°
180°
A CB
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX – 6 Couplant : Greace
Equipment : 3.1/2” Lubricator x 8 ft Tag No. : CRS 0497-4-2/2 Description of Item
PartMaterial Thickness Minimal Wall Thickness
(mm)00 900 1800 2700
A 16.66 16.30 16.82 16.43 16.30B 16.65 17.52 16.95 16.27 16.27C 16.50 17.15 16.04 16.98 16.04
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
90°
0°
270°
180°
A CB
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX – 6 Couplant : Greace
Equipment : 4.1/2” Lubricator x 8 ft Tag No. : CRS 0497-7-2/2 Description of Item
PartMaterial Thickness Minimal Wall Thickness
(mm)00 900 1800 2700
A 23.34 23.34 23.30 23.02 23.02B 24.75 24.09 23.10 26.47 23.10C 23.48 23.55 23.23 23.39 23.23
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
90°
0°
270°
180°
A CB
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX – 6 Couplant : Greace
Equipment : 4.1/2” Lubricator x 8 ft Tag No. : CRS 0497-7-1/2 Description of Item
PartMaterial Thickness Minimal Wall Thickness
(mm)00 900 1800 2700
A 23.51 23.38 23.09 23.77 23.09B 25.05 23.29 22.20 24.18 22.20C 23.48 23.55 23.23 23.39 23.23
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
90°
0°
270°
180°
A CB
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX – 6 Couplant : Greace
Equipment : 4.1/2” Lubricator x 8 ft Tag No. : CRS 0497-9-1/1 Description of Item
PartMaterial Thickness Minimal Wall Thickness
(mm)00 900 1800 2700
A 23.02 23.08 23.35 23.74 23.02B 22.18 22.47 23.39 24.10 22.18C 23.19 23.11 23.40 23.36 23.11
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
90°
0°
270°
180°
A CB
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX – 6 Couplant : Greace
Equipment : 4.1/2” Lubricator x 4 ft Tag No. : CRS 0497-8-1/1 Description of Item
PartMaterial Thickness Minimal Wall Thickness
(mm)00 900 1800 2700
A 23.11 23.46 23.77 23.33 23.11B 23.46 22.69 22.69 23.27 22.69C 23.52 23.03 23.74 23.16 23.03
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
90°
0°
270°
180°
A CB
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Pumping Tee 4.1/2”Tag No. : NS/NO 321/11/B/01
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 18.70 18.64 18.71 18.80 18.64B 18.67 18.62 18.55 18.47 18.47C 18.76 18.35 18.42 18.84 18.35
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
C
B
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Tree Adaptor ( Half Clamp)Tag No. : EN - MJM – 001 RX 35 HT-001BB-130-20655
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 27.13 27.10 27.18 27.16 27.10
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Tree Adaptor ( Half Clamp)Tag No. : EN - MJM – 119-HT-001 BB-170-5513
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 13.66 13.59 13.69 13.57 13.57
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Pumping Tee 3.1/2”Tag No. : EN MJM-097-TT-001 BB 200-9051Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 5.30 5.50 5.14 5.21 5.14B 22.88 22.91 22.92 22.36 22.36C 14.72 14.63 14.64 14.70 14.63
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
C
B
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Lubricator X - OverTag No. : EN Lubricator X-over 6.1/2”-4 ACME x 5” PNP 01 08 05Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 18.94 18.46 18.98 18.72 18.72
B 8.13 8.17 8.22 8.12 8.12
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A B
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Adaptor Dual CameronTag No. : EN-MJM-001 5”-4 ACME HT 001BB 200-9051
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 19.33 19.28 19.31 19.29 19.28
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Tree Adaptor Tag No. : EN - MJM-098-WT-001 BB-220-5559
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 33.16 33.11 33.09 33.14 33.09
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Adaptor Single Cameron 3.1/2” Tag No. : EN-MJM-031A-OT-001 BB 160-32693
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 18.62 18.68 18.77 18.88 18.62
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Elbow Ø2” Item No. : EN ELB 01
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 11.68 12.37 11.93 12.06 11.68
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Chicksan Female to Female Ø2” Tag No. : EN – CF - 06
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 11.08 11.09 11.12 11.11 11.08
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Check Valve Ø2”Tag No. : EN - MJM-034-W-002Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 19.68 19.75 19.08 19.07 19.07
B 10.57 10.33 10.41 10.44 10.33
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
B
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Liquid Chamber Tag No. : EN-48 AD/05-140-01
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 15.05 15.15 15.25 15.20 15.05
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Weco Valve Serial No. : 578567
Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 14.97 15.15 15.25 15.20 14.97
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
A
ULTRASONIC WALL THICKNESS REPORTNo. 611 / INSP-PKS / III / 2012
Owner/ User : PT. NESITOR Date of Tested : March 30th, 2012 Report No. : No. 611/INSP-PKS/III/2012 Location : NESITOR - 3
Recorder:Equipment : Ultrasonic Wall Thickness Probe : 250” HDManufacturer :Dakota Ultrasonic Frequency : 5 MHzType/Model : MMX - 6 Couplant : Greace
Equipment : Crossever Tag No. : PARVEEN S/N NO 389/03/05-02Description of Item
PartMaterial Thickness Minimal Wall
Thickness (mm)00 900 1800 2700
A 30.70 30.44 30.39 30.55 30.39B 30.70 30.38 30.39 30.55 30.38
Owner Surveyor / Superintendent
( )
Inspector,
( Agung sulistiono )
B
A