Upload
cristina-castillo
View
102
Download
8
Embed Size (px)
Citation preview
5858
288
Test Mode
Direct Transmission Indirect or
Surface TransmissionSemidirect Transmission
CONCRETE TESTING
NDT / Protection and repair of concrete structures . . Quality and homogeneity evaluation
Ultrasonic pulse velocity (continued)
Testing equipment for the construction industry
REBOUND MEASUREMENT
q STANDARD
EN 12504: Part 4, BS 1881:203, ASTM
C597, NF P18-418, UNI 7997-9189-9524,
UNE 83308, CUR 69
� 58-E0049/B
Dual Tester for Ultrasonic and
Rebound tests including electronic
rebound hammer directly connected
� 58-E0049/A
Dual Tester for Ultrasonic and
Rebound tests (with manual input
of rebound hammer results)
General description and specifications
Measures the velocity of ultrasonic pul-ses through a concrete section providing information on cracks, voids, strength and gives quick estimates of dynamic modulus of elasticity and Poisson’s Ratio, on site or in the laboratory. Can also be used for estimating times for formwork striking. The pulse velocity can be combined with the rebound hammer value for the streng-th evaluation based on the mathematical equation of the test report CUR 69 publi-shed by the Research Institute of the Dutch Concrete Association.The measuring unit houses an integral data logger for data acquisition and processing with memory for up to 1200 readings.The model 58-E0049/B combined tester is a compact apparatus including UPV meter and electronic rebound hammer.
58-E0049/B tester
This provides significant practical and eco-nomic benefit by offering one system for both ultrasonic and rebound testing. The 58-E0049/A version provides a lower cost alternative which gives the same results but with manual input of rebound results measured using a standard concrete ham-mer 58-C0181/N.
- UNIQUE FEATURE:
Combined ultrasonic and rebound ham-
mer determination
- Non-destructive evaluation of homoge-
neity of concrete and detection of cracks
and voids
UPV meter
Microprocessor incorporatedFrequency range: 24 to 150 kHz
Receiver input impedance: 1 MΩ
RS 232 output Connectable to oscilloscopeTransit time measurement: from 0.1 to 1999.9 µs
Pulse rate: from 1 to 10 per second, selectable
Accuracy: 0.1 µs
Transmitter output: up to 1500 V
Battery operated by internal rechargeable battery pack and internal chargerBattery life: 18 working hours
Electronic concrete test hammer
Impact energy: 2.207 N•m
B Dimensions: dia. 78x335 mm
A Weight approx.: 1 kg
- Non-destructive estimation of the
mechanical properties of the concrete,
strength and modulus of elasticity
- Light, portable and easy to use
- Probe with sampling button
5858
289
Spare parts
s58-E0046/1 Cylindrical head, 54 kHz nominal frequency, dia. 50x54 mm
s58-E0046/S Cylindrical head with sampling buttom, 54 kHz nominal fre-quency, dia. 50x54 mm.
s58-E0048/5 Spare 3 m cable for transducers or for oscilloscope connec-tion
s58-E0046/3 Coupling agent (contact paste), 250 cc bottle
CONCRETE TESTING
. . NDT / Protection and repair of concrete structuresQuality and homogeneity evaluation
Ultrasonic pulse velocity (continued)
Testing equipment for the construction industry
General
Memory: stores up to 1,200 results
Power supply: internal rechargeable batteries and internal battery charger
Ambient temperature range: 0-40°C
RS 232 outputB Dimensions: 210x300x300 mm approx.
A Weight approx.: 3 kg
Standard outfit
The standard version comprises the 54 kHz Transmitter and Receiving heads (one of the two probes is fitted with a sampling button in order to select readings to be recorded) with 3 m cable, calibration rod, 250 cc bottle of contact paste and carrying case. Electronic rebound hammer included (58-E0049/B model only).
sCode Nominal Shape Dimensions frequency (mm) (kHz)
58-E0046/30 24 cylindrical dia. 50x7558-E0046/33 150 cylindrical dia. 25x54
Other available heads
Oscilloscope
s58-E0048/10 Oscilloscope. For labo-ratory use. 110-230, 50-60 Hz, 1 ph. Complete the oscilloscope with three cables 58-E0048/5. See spare parts.
UPV meter calibration
The tester is supplied complete with a 150 mm calibration rod corresponding to approx. 50 µs transit time.
Accessories
Testing headsThe 54 kHz transducers are supplied with the tester because this is the assumed standard. Different heads are available with different nominal working frequency, between 24 and 150 kHz (this is the usual range for normal concrete): the highest frequencies (82, 150 kHz) are indicated for homogeneous concrete, the lowest (24 kHz) for heterogeneous concrete.
58-E0048/10
58-E0046/1S Probe with sampling button(for 58-E0049/B and 58-E0049/A only)
Sampling button