Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
FMSUltrasonic Meters Catalog
Ultrasonic meter is the ideal choice for
continuous and discrete measurement
of level and flow for
liquid, solid and gas,
without physical contact
We develop, build and sell standard and customized ultrasonic solutions for
process control
From a single instrument, to complex
infrastructure, we have all you need
for measure, log, transmit, process,
control and monitor
Under the FMS logo, Plandata join years of software and electronic
experience, to the excellence of it’s partners and suppliers
FMS is a commercial brand of Plandata. All other brands referenced on this document
are property of their owners.
Plandata CSI Ltdahttp://www.plandata.com.br
phone 55+11+55624981
Ultrasonic measurement bring advantages because they are
higienic, precise, quick,
immune, reliable, simple,
economic, versatile.
Our systems offer a set of parameters for configuration and customization to
suit your preferences and needs
Shot: Power of wave
Temp: Temperature of environment
Sample: Intensity of measurement
Freq: Frequency adjustment
Password: Access protection
Flume/Weir/Tank/Pipe: Choose types
EngUnit: Choose engineering unit
Trimpot: Digital fine calibration
Output: Interface type
Range: Limits of operation
Margin: Stabilization under turbulence
and much more
Here you will find a complete guide to our ultrasonic solutions
Fluid Management System
Available for tanks of different sizes and shapes. .
Measurement and linearization in several engineering units like mts, kgs, lts, etc.
Specially usefull for food, beverage, chemical, environment, monitoring, oil, álcohol, mining, agriculture, water, wastewater and effluent among others.
Level range from 100 mm to 12000mm or wider on request.
Ultrasonic Level Meter/Switch
Ultrasonic Flow Meter/Switch
Non contact level measurement for liquid and solid.
Recommended for agriculture, water treatment, wastewater, effluent and others.
Several models for any type of flume like Parshall, Palmer-Bowlus, Leopold-Lagco,H, HS, etc andWeirs of type Retangular, V-notch,Cipolletti, etc.
Totalization as standard and datalog as an option.
Flow range from 0,1 l/s up to 4000 l/s or wider on request. Measure instantaneous flow
in open channel like flumes and weirs.
ULM130
UFM130
SPECIFICATIONS
LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5%
1% or less than 1mm ABS, IP65
-40 to +90 celcius 1mt as standard extensible to up 100mts
-30 to +55 celcius -40 to +90 celcius
85% 100%
IP68 110VAC or 220VAC, both 50/60HZ or 24VDC
All types typical 1,6 watts max 6 watts
Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio
Modbus as standard or customized on request
Model ULM140-1: 100mm to 2000mm Model ULM140-2: 200mm to 4000mm Model ULM140-3: 250mm to 6000mm Model ULM140-4 350mm to 8000mm Model ULM140-5 400mm to 12000mm
1,7 Kg BSP 1”
182mm x 172mm x 92mm Manual as standard, Automatic as option
Not recommended for liquids with dense foam
HMI:Repeatability:Precision:Cabinet Material and Protection: Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Load:Interfaces options:
Digital protocol:Level range:
Weight:Process connection:Dimension:Temperature compensation:
SPECIFICATIONS
LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5%
1% ABS, IP65
-40 to +90 celcius 1mt as standard extensible to up 100mts
-30 to +55 celcius -40 to +90 celcius
85% 100%
IP68 110VAC or 220VAC, both 50/60HZ or 24VDC
All types typical 1,6 watts max 6 watts
Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio
Modbus as standard or customized on request 0,1 l/s to 4000 l/s
1,7 Kg BSP 1”
182mm x 172mm x 92mm Manual as standard, Automatic as option
Not recommended for liquids with dense foam
HMI:Repeatability:Precision:Cabinet Material and Protection: Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Load:Interfaces options:
Digital protocol:Flow range:Weight:Process connection:Dimension:Temperature compensation:
Ultrasonic Flow Meter
Measure instantaneous and totalized, volumetric liquid flow in pipes (clamp-on)
Available for pipes of different material like steel, iron and many plastics.
Non-intrusive external clamp-on transducers, no need to cut or drill pipes.
Interference free. No pressure drop.
Large standard flow range from 10 l/s to 4000 l/s or other on request.
Wide range of pipe diameters coverage 25mm to 6000 mm. Almost all type of liquids.
Datalog standard available.
SPECIFICATIONS
LCD 2 lines 16 column, keyboard 4 keys 0,5%
1% IP65 0 to 100 celcius
5mts as standard or customized -30 to +80 celcius
-40 to +100 celcius 85%
100% IP68 1 mt water immersion
110VAC or 220VAC, both 50/60HZ or 24-36VDC All types with <10000 ppm solids suspension 10 l/s to 4000 l/s
Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio
Modbus as standard or customized
Model UFM140-1: 12,5mm to 100mm Model UFM140-2: 50mm to 700mm Model UFM140-3: 275mm to 6000mm
2,5 KgNot recomended for lined pipes (see our UFM150 models)
HMI:Repeatability:Precision:Cabinet Protection:Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Flow range:Interfaces options:
Digital protocol:Pipe diameters:
Weight:
UFM140
Measure instantaneous and totalized, volumetric liquid flow in pipes (wetted)
Suitable for pipes of different material like steel, iron and many plastics. For use with pipes that can not accept external transducers like lined pipes.
Intrusive transducers.Require drill into pipes.
Minimal negligible pressure drop, less than 0,1%
Large standard flow range from 10 l/s to 4000 l/s or other on request.
Wide range of pipe diameters coverage 80mm to 6000 mm. Almost all type of liquids.
Better precision.
Datalog standard available.
Ultrasonic Flow Meter UFM150 SPECIFICATIONS
LCD 2 lines 16 column, keyboard 4 keys 0,5%
Less than 1% IP65 0 to 100 celcius
5mts as standard or customized -30 to +80 celcius
-40 to +100 celcius 85%
100% IP68 1 mt water immersion
110VAC or 220VAC, both 50/60HZ or 24-36VDC All types with <10000 ppm solids suspension 10 l/s to 4000 l/s
Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio
Modbus as standard or customized
Model UFM150-1: 80mm to 200mm Model UFM150-2: 180mm to 700mm Model UFM150-3: 500 to 6000mm
2,5 KgNot recomended for pipes bellow 80mm (see our UFM160 models)
HMI:Repeatability:Precision:Cabinet Protection:Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Flow range:Interfaces options:
Digital protocol:Pipe diameters:
Weight:
Ultrasonic Flow Meter
Available for pipes of different material like steel, iron and many plastics.
Flow cell, with pre assembled transducers providerobust and long term stability.
Interference free. No pressure drop.
Medium standard flow range from 10 l/s to 3000 l/s
Specific range of pipe diameters coverage 10mm to 1000 mm. Almost all type of liquids.
Datalog standard available.
SPECIFICATIONS
LCD 2 lines 16 column, keyboard 4 keys 0,5%
Less than 1% IP65 0 to 100 celcius
5mts as standard or customized -30 to +80 celcius
-40 to +100 celcius 85%
100% IP68 1 mt water immersion
110VAC or 220VAC, both 50/60HZ or 24-36VDC All types with <10000 ppm solids suspension 10 l/s to 3000 l/s
Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request
Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio Modbus as standard or customized
Model UFM160-1: 10mm to 50mm Model UFM160-2: 50mm to 1000mm
Available on request Steel and Iron
HMI:Repeatability:Precision:Cabinet Protection:Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Flow range:Interfaces options:
Digital protocol:Pipe diameters:
Weight:Flow Cell Material:
Measureinstantaneous and totalized, volumetric liquid flow in pipes (flow cell)
UFM160
Ultrasonic Flow Meter
Measureinstantaneous and to volum in pi
talized,etric liquid flow
pes (portable)
Available for pipes of different material like steel, iron and many plastics.
Non-intrusive external clamp-on transducers, no need to cut or drill pipes. Password protected.
Interference free. No pressure drop.
Large standard flow range from 10 l/s to 4000 l/s or other on request.
Wide range of pipe diameters coverage 25mm to 6000 mm. Almost all type of liquids.
Datalog standard included. Wireless supervisory via Spread Spectrum Radio or GSM/GPRS on request.
Battery charger included. Standard battery for 10 hours of continuous operation.
SPECIFICATIONS
LCD 4 lines 16 column, keyboard 18 keys 0,5%
Less than 1% IP65 0 to 100 celcius
5mts as standard or customized on request -30 to +80 celcius
-40 to +100 celcius 85%
100% IP68
110VAC or 220VAC, both 50/60HZ for charger All types with <10000 ppm solids suspension 10 l/s to 4000 l/s
Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio
Modbus as standard or customized
Model UFM170-1: 12,5mm to 100mm Model UFM170-2: 50mm to 700mm Model UFM170-3: 275 to 6000mm
6 KgAAA rechargeable NiMH
HMI:Repeatability:Precision:Cabinet Protection:Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Flow range:Interfaces options:
Digital protocol:Pipe diameters:
Weight:Battery:
UFM170
Ultrasonic Flow Meter
Measureinstantaneous and totalized, volumetric gas flow in pipes (clamp-on)
Available for pipes of different material like steel, iron and many plastics. Messure flow of most kind of gás including natural, corrosive, tóxic, compressed air etc ...
Non-intrusive external clamp-on transducers, no need to cut or drill pipes.
Interference free. No pressure drop.
Large standard flow range from 14 m/s to 150 m/s.
Wide range of pipe diameters coverage 20mm to 600 mm. Support several temperature and pressure profiles.
Datalog standard available. Explosion proof as option Class 1, Div 1, Groups BCD.
SPECIFICATIONS
LCD 2 lines 16 column, keyboard 34 keys 0,5%
1% to 5% depending on diameter and channels used IP65
-40 to +230 celcius 5mts as standard or customized
-10 to +55 celcius -20 to +60 celcius
85% 100%
IP68 110VAC or 220VAC, both 50/60HZ or 24VDC
All types with minimum density volume 0-1000000 m3/s, velocity 14-150 m/s
Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request
Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio Modbus as standard or customized
Model UFM180-1: 20mm to 100mm Model UFM180-2: 100mm to 200mm Model UFM180-3: 200mm to 300mm Model UFM180-4: 300mm to 600mm
5Kg Steel and Aluminun
360x290x130 mm 20D upstream, 10D downstream, free flow
HMI:Repeatability: <Precision:Cabinet Protection:Gas Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Gas type:Flow range:Interfaces options:
Digital protocol:Pipe diameters:
Weight:Transducer Material:Dimension:Requirement:
UFM180
Measureinstantaneous and totalized, volumetric steam flow in exhaust or waste pipes and chimneys (wetted)
Available for pipes and tubulation of any material like steel, iron, concrete and plastics. Measure flow of most kind of vapor and smoke.
Intrusive transducers..
Negligible interference to flow.
Support aggressive, high dust, high temperature and low speed media.
Standard flow range from 0 m/s to 40 m/s.
Wide range of pipe diameters coverage 1000mm to 10000 mm. Support several temperature and pressure profiles with automatic compensation.
Datalog standard available.
SPECIFICATIONS
LCD 2 lines 16 column, keyboard 34 keys 0,5%
2% depending on diameter and channels used Ip54, Ip65 depending on parts
0 to +400 celciusFan system for transducer cooling and cleaning
-10 to +50 celcius -40 to +80 celcius
85% 100%
IP68 110VAC or 220VAC, both 50/60HZ or 24VDC
Smoke and Vapor volume 0-3000000 m3/h, velocity 0-40 m/s
Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request
Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio Modbus as standard or customized
Model UFM190-1: 2000mm to 5000mm Model UFM190-2: 3500mm to 8000mm Model UFM190-3: 4500mm to 10000mm
25 to 35Kg Steel and Ceramic
360x400x230 mm 20D upstream, 10D downstream, free flow
HMI:Repeatability: <Precision:Cabinet Protection:Gas Temperature:Ventilation: Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Media type:Flow range:Interfaces options:
Digital protocol:Duct diameters:
Weight:Transducer Material:Dimension:Requirement:
Ultrasonic Flow Meter UFM190
Digital Interfaces (options)
Provide easy way for monitoring, controling and supervisioning your instrument and data remotely.
Data output and configuration input using standardModbus RTU protocol or a customized protocol on request.
Baudrates up to 115Kbps
Deliver measured data directly into your PC or PLC.
Serial Rs232and Rs485CommunicationInterfaces
SPECIFICATIONS
Rs232: 5-15 mts depending on environment Rs485: 500-1000 mts depending on environment
IP65 -40 to +90
Connector type: Standard DB9Cable Range:
Connector Protection:Operation Temperature:
Ethernet TCP/IPCommunicationInterface
Provide easy way for monitoring, controling and supervisioning your instrument and data remotely.
Data output and configuration input using standardModbus TCP protocol or a customized protocol on request.
Baudrates up to 100/1000Kbps
Deliver measured data directly into your LAN(local area network) or WAN (wide area network).
Conventional: 250 mts depending on environment Fiber Optic: > 1000 mts
IP65 -40 to +90
SPECIFICATIONS
Connector type: Standard RJ45Cable Range:
Connector Protection:Operation Temperature:
GSM/GPRSCellular WireLessCommunicationInterface
Provide a way to connect your instrument each other or to a remote Data Base Server or SCADA.
You may store data into the Data Base Server supplied by your local carrier or we can develop your own custom, private Data Base Server on request. Data Base Server collect and store your data over a LAN(local area network) or WAN (wide area network).
GSM dual band.
Data output and configuration input using standardModbus TCP, HTTP, OPCServer, SMS protocols or a customized protocol on request.
Baudrates up to 14Kbps.
Global approvals and most carriers compatibility.
MMCX/SIM 850/1900MHz and 900/1800MHz
10 1 and 2
-30 to +55 Yes
Yes
Ascii TXT, DBF, MSSQL, XLS Excell, or other on request
Modbus TCP, HTTP, OPCServer, SMS or custom Up to 4000 points/station
Windows 200x for Data Base & SCADA
SPECIFICATIONS
Antenna Connector type:GSM band:GPRS Class:GSM Class:Operation Temperature: Dial up:Auto Answer:DataBase Options:
Protocols:SCADA:Requirements:
FHSS RadioDigitalWireLess CommunicationInterface
Provide a way to connect your instrument each other or to a remote Data Base Server or SCADA.
You may store data into the Data Base Server supplied by your IT or we can develop a custom Data Base Server on request. Data Base Server store your data collected from a LAN(local area network) or WAN (wide area network).
FHSS Frequency Hopping Spread Spectrum is licence free on most countries.
Data output and configuration input using standardModbus RTU, Modbus TCP protocol or a customized protocol on request.
Baudrates up to 19Kbps. Deliver data right into your PC, PLC, LAN or WAN..
Standard ISM 902/928MHz
-30 to +55 Programable max1 Watt
Point to Point, Point to Multipoint, Multipoint to Multipoint
Ascii TXT, DBF, MSSQL, Excell XLS, or other on request
12VDC -100dBm
48 +- 32Km with line of sight
max 19Kbps Rs232, Rs485, Ethernet
Modbus RTU or Modbus TCP 22 x 75 x 110 mm
Windows 200x for Data Base & SCADA
SPECIFICATIONS
Antenna Connector Type:Band:Operation Temperature: Load:Topologies:DataBase Options:
Power:Sensitivity:Channels:Range:Baud Rate:Digital Output:Protocol:Dimensions:SCADA: Up to 4000 points/stationRequirements:
Analog OutputInterface0-5V, 0-10V4-20mA, 0-20mA
Analog Interfaces (options)
Analog signaling output.Output the engineering unit of your choice.Voltage 0-10VDC or 0-5VDCCurrent 4-20mA or 0-20mAHigh resolution.High immunity.Long distance cabling.1 to 5 output per instrument
16 bits Max 700 OhmsI
-30 to +55 24VDC
1 to 5 each meter
SPECIFICATIONS
Resolution:Impedance:Operation Temperature: Voltage for current loop:Outputs:
Relays OutputInterface110VAC, 220VAC,24VDC
Resistive 5Ah 120VAC or 240VAC or 24VDC
-40 to +70 max 10Ahmax 50 Ohms
300 switch/min 10ms max
5ms max Silver alloy
SPECIFICATIONS
Load Type:Nominal Power Rate:Operation Temperature: Switching Current:Initial Resistance: Mechanical Life:Switch Time:Release Time:Contact Material:
Ideal for pump, valves, mixers, alarms etc..Double set points assignmentsSpecial set points on request.3 relays 5Ah, 6 relays 2Ah and 9 relays 1Ah as standard or custom specification on request.
Auxiliar Sensor InputInterface.Temperature,Pressureand others
We integrate auxiliar sensor inputs to improve your ultrasonic flow & level FMS metering system.
Pressure, Temperature and more.
For compensation, for process control or research.
Especial software routines can be made on request.
Robust and reliable sensors supplied by our market leader partners.
Steel AISI 316 Better than 0,25%
-25 from +75 24VDC to 36VDC
from Ip65 to Ip68 Immersible available on request 0/160mmCA to 0/2500mmCA
-20C to +600C
SPECIFICATIONS
Materials:Precision:Operation Temperature: Voltage for current loop:Protection: Pressure Ranges:Temperature Ranges:
FMS is a commercial make of Plandata. All other makes are property of their owners. Plandata reserve the right to modify any specification without previous advertise