Upload
buikien
View
239
Download
2
Embed Size (px)
Citation preview
TUF-2000F2 ULTRASONIC FLOWMETER / HEATMETER
Dalian Taosonics Instrument Co., Ltd.www.tuf-2000.com
SERIES
CONTENTS
OVER 20 YEARS' EXPERIENCES
SPECIALIZED IN ULTRASONIC FLOW METERS
PROFILE 1
Fixed Mounted Inline Type Ultrasonic Flow Meter/Heat Meter 2-6
Fixed Mounted Clamp On Ultrasonic Flow Meter/Heat Meter 7-10
Fixed Mounted Insertion Type Ultrasonic Flow Meter/Heat Meter 11-13
Data Sheet & Model Selection 14
Wiring And Waterproof 15
Certification 16
Fixed mounted Π type inline ultrasonic flow meter 2-3 Standard inline type ultrasonic flow meter 3-4Fixed mounted inline type ultrasonic heat meter 5-6
Fixed mounted clamp on ultrasonic flow meter 7-9 Fixed mounted clamp on ultrasonic heat meter 9-10
Fixed mounted insertion type ultrasonic flow meter 11-12 Fixed mounted insertion type ultrasonic heat meter 13
TUF 2000F2- ULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
. - .www tuf 2000 com
TUF 2000F2- ULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd. . - .www tuf 2000 com1
Whole machine waterproof:whole machine is sealed completely reaching IP68 protection level.Parts waterproof :Each part is waterproof,operating normally in the event of water inside .
Communication interface:RS485 interface
Output: 4-20mA analog/OCT pulse/Relay signal
Heat measurement:achieve heat measurement by connecting
3-wired PT100 temperature transducers
Input: 3 way 4-20mA analog input, acquisition signals of temperature,
press, liquid level,etc.
Temperature range:-30℃~160℃
P/N :0~2.5Mpa (Optional)
Accuracy:0.5%、1% .
No rotation, no moving parts , Long term measurement with high accuracy.
Applicable to variety of water quality, including the water gravel and weeds.
4-key board design,support setting operation password .
TUF-2000F2 series Ultrasonic Flow/Heat Meter is the new product of Dalian Taosonics Instrument Co., Ltd, it is designed strictly according to JJG1030-2007 standard to develope the reliability of protection class. Ultrasound transmit time principle makes the measurement range from DN25 to DN6000.
The advantages include high accuracy,strong anti-interference, reliability and stability,multiple interface. Each parts can achieve to IP68, enable the meter work in any severe environment.
IP68 PROTECTION CLASS
WATERPROOF KEYBOARD
MULTIPLE INTERFACE
TEMPERATURE AND PRESSURE
HIGH ACCURACY MEASUREMENT
ULTRASOUND MEASUREMENT
Typica
l App
licati
on
1 、πType Inline Ultrasonic Flow Meter(DN15mm~DN32mm)
FLANGE CONNECTION
THREAD CONNECTION
2 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
The measuring range of π type inline ultrasonic flow meter is DN15mm~DN32mm,by flange connection or thread connection. IP68 protection level. measuring temperature range -30℃~160℃,P/N 0~4.0Mpa, high accuracy within ±0.5%。(Please refer to page14 for detailed parameters).
Measuring Diagram
D 15N
D 20N
D 25N
D 32N
2 5.2 5.2 5.2 5.
320 1 21 285
360
390
450
13
15
16
22 5.
G3 4B/
G 1B
G1 1 4 B/
G 1 1 2B/
1 21
1 21
1 21
285
292
292
Nominal Diameter( )DN
Pressure Level
P
LengthL
WidthW
HeightH
Thread LengthL 1
Thread Standard
GB T7307-2001/Standard of Thread:
H
wL
D D2D1
C
D 15N
D 20N
D 25N
D 32N
2 5.
2 5.
2 5.
2 5.
320 148 285360
390
450
95
10 5
115
14 0
153
158
170
NominalDiameter( )DN
PressureLevel
Lengthl
PL
Width
W
Height
HBolt Hole Centers
D1
Sealing Surface
Diameter D2
GB T 9119-200 0/Standard of Flange:
NormalSize
D
Bolt Hole X Quantity ∮X n
Flange ThicknessBolts
Dimension C f
65 14 4x 46 1475 56 1685 65 16
10 0 76 18
14 4x
14 4x
18 4x
2
22
2
M 12 50x
M 12 50x
M 12 50x
M 16 60x
Flange Dimension
285
292
292
Flange Connection
L1H
W
Unit:
Unit:
L
Thread Connection
Dimension
3 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
Measuring Diagram
2、Standard Inline Ultrasonic Flow Meter(DN40mm~DN1000mm)
W
H
L
D D2D1
C
f
4 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
The measuring range of Standard inline type ultrasonic flow meter is DN40mm~DN1000mm, with high protection class of IP68, measuring fluid temperature of -30℃~160℃, pressure range of 0~2.5Mpa, high accuracy within ±0.5%.(Please refer to page14 for detailed parameters)
Dimension
Unit:
Nominal Diameter( )DN
P/N
P
LengthL
WidthW
HeightH
Bolt Hole Centers
D1
SealingSurface
DiameterD2
Outer Diameter
D
Bolt Hole X Quantity
∮X n
Flange Thickness
c f
Flange Dimension
Bolt Specification
40
50
65
80
100
125150200
250300
350
400450
500
6 00
7 00
8 00
9 0010 00
1 6.
1 6.
1 6.
1 6.
1 6.
1 6.1 6.
1 6.
1 6.
1 6.
1 0.
1 0.1 0.
1 0.
1 0.
0 6.
0 6.
0 6.0 6.
30 0
30 0
30 0
22 5
25 0
27 530 035 0
45 050 0
55 0
60 070 0
800
1000
11 00
1200
13001400
150
165
185
200
220
250285340
405460
500
565615
670
780
860
975
10751175
110
125
145
160
180
210240295
355410
460
515565
620
725
810
920
10201120
18 4x
18 4x
18 4x
18 8x
18 8x
18 8x
22 12x26 12x
26 12x
23 16x25 16x
25 20x
25 20x
30 20x
25 24x
30 24x
30 24x
30 24x
30 28x
8499
118
132
156
184
211266
319370
428
482532
585
685
775
880
980
1080
18 2
2022
22
2022
2224
262832
28
3030
32
36
32
32
34
36
222
222
24
5
4
4
4
5
5
5
5
M1 6 60x
M1 6 70xM1 6 70x
M1 6 80x
M1 6 80x
M2 0 80xM2 0 90xM2 2 90x
M2 2 90xM2 2 90x
M2 0 80x
M2 2 90xM2 2 90xM2 2 90x
M 27 110xM2 2 90x
M 27 100x
M 27 100x
M 27 110x
Standard Of Flange: GB T 9119 -2 000 (DN40~300) // 81-94 (DN350~1000) JB T
336
349
366
381
401
428459511
569621
666
697774
826
931
1021
1129
12291329
150
165
185
200
220
250285340
405460
500565615
670
780
860
975
107511 75
5 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
Optional Temperature Transducers(3-wired PT100)
3、Inline Ultrasonic Heat Meter
Clamp on temperature Transducer Pt100 CT-1 ≥DN50 -40 160~ ℃
℃± . ℃100 0 8
No
Yes
No
Yes
Insertion temperature Transducer Pt100
Insertion Pt100Installation with pressure
-40 160~ ℃
-40 160~ ℃
≥DN50
≥DN50
TCT-1
PCT-1
Insertion Pt100Small size pipe diameter SCT-1 DN50 -40 160~ ℃
Picture Specification Model Meas. Range Temperature Cut off water Accuracy
6 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
supply pipe
return pipe
It can achieve to heat measurement by connecting 3 way PT100 transducer. Accuracy:±1.0%, Heat meter’s dimension is the same as In-line ultrasonic flow meter, except that the height increased 70mm.
Measuring Diagram
Dimension & Installation
Bolts Fixed Steel Belt Fixed
155mm
150mm
265mm
117mm
Fixed Mounted Clamp On Ultrasonic Flow Meter/Heat Meter
1、Fixed Mounted Clamp On Ultrasonic Flow Meter
7 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
Both converter and transducer are fixed on the pipeline, no need to cut off the pipeline, simplifying installation process. Wide measuring range of DN25mm~DN6000mm, IP68 protection class, measuring fluid temperature of -30℃~160℃,no limit for pressure , high accuracy within ±1%.(Please refer to page 14 for detailed parameters)
Measuring Diagram
Unit:
Optional Transducers
Standard Transducers
High Temperature Transducers
Mounting Bracket Transducers
Optional Clamp On Transducers
Standard Clamp On Transducers
High Temperature Clamp On Transducers
8 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
Description
Small Size
Medium SizeLarge Size
Small Size
Medium SizeLarge Size
Model Measuring Range Fluid Temperature Dimension
Description Model Measuring Range Fluid Temperature Dimension
Built-in magnet,attached to pipe surface Easily.IP68 if be sealed with Gel.Complete specifications,wide measuring rangeof DN25mm~DN6000mm.Fluid temperature :-30℃~160℃.
Built-in magnet,attached to pipe surface directly.IP68 if be sealed with Gel.Complete specifications,wide measuring rangeof DN25mm~DN6000mm.Fluid temperature :-30℃~160℃.
9 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
Mounting Bracket Clamp On Transducers
Improve installation efficiency and installation accuracyIP68 protection class.Measuring range: DN25mm~DN700mm.Fluid temperature :-30~160℃
Description Model Measuring Range Fluid Temperature Dimension
Small Size
Medium SizeLarge Size
High Temperature Small Size
High TemperatureMedium Size
High Temperature Extended
~DN700
~DN700
2、Fixed Mounted Clamp On Ultrasonic Heat Meter
It can achieve to heat measurement by connecting 3 way PT100 transducer. No need to cut off the watersupply for installation. Protection class: IP68. Accuracy:±2.0%.Wide measuring range of DN25mm~DN6000mm by selecting different transducers.
Measuring Diagram
supply pipe
return pipe
Optional Temperature Transducers(3-wired PT100)
Clamp on temperature Transducer Pt100 CT-1 ≥DN50 -40 160~ ℃
℃± . ℃100 0 8
No
Yes
No
Yes
Insertion temperature Transducer Pt100
Insertion Pt100Installation with pressure
-40 160~ ℃
-40 160~ ℃
≥DN50
≥DN50
TCT-1
PCT-1
Insertion Pt100Small size pipe diameter SCT-1 DN50 -40 160~ ℃
Picture Specification Model Meas. Range Temperature Cut off water Accuracy
10 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
TUF 2000F2-11 . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
1、Fixed Mounted Insertion Ultrasonic Flow Meter
Both converter and transducers are fixed on the pipeline, no need to cut off water, reliable and stablein operation. Wide measuring range of DN50mm~DN6000mm, IP68 protection class, measuring fluid temperature of -30℃~160℃,no limit for pressure , high accuracy within ±1.0%.(Please refer to page 14 for detailed parameters)
155mm
150mm
265mm
117mm
Fixed Mounted Insertion Ultrasonic Flow Meter/Heat Meter
Dimension & Installation
Measuring Diagram
Unit:
Bolts Fixed Steel Belt Fixed
Optional Transducers
Standard Transducers
Lengthen Transducers
Parallel Transducers
12 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
Optional Insertion Type Transducers
Standard Insertion Transducers
Lengthen Insertion Transducers
Parallel Insertion Transducers
Applicable for the pipeline can be directly welded, like carbon steel and stainless ,etc.Pipe wall thickness≤20mmMeasuring range:DN50mm~DN6000mmFluid temperature: -30~160℃
Applicable for the pipeline can not be directly welded, like cement ,PVC ,cast iron,steel,composite material,etc.Pipe wall thickness≤70mmMeasuring range:DN50mm~DN6000mmFluid temperature: -30~160℃
Applicable for the pipeline then there is not enough installation spacePipe material is unlimited Wall thickness is unlimited and Insertion depth should be 1/3 of pipe inner diameter Measuring range: DN80mm~DN6000mmFluid temperature: -30~160℃
2、Fixed Mounted InsertionType Ultrasonic Heat Meter
It can achieve to heat measurement by connecting 3 way PT100 transducer. No need to cut off the water supply for installation with a high accuracy of ±2.0% . Long term operation with high stability and reliability IP68 protection class. Wide measuring range of DN50mm~DN6000mm by selecting different insertion transducers.
13 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
Measuring Diagram
supply pipe
return pipe
Optional Temperature Transducers(3-wired PT100)
Clamp on temperature Transducer Pt100 CT-1 ≥DN50 -40 160~ ℃
℃± . ℃100 0 8
No
Yes
No
Yes
Insertion temperature Transducer Pt100
Insertion Pt100Installation with pressure
-40 160~ ℃
-40 160~ ℃
≥DN50
≥DN50
TCT-1
PCT-1
Insertion Pt100Small size pipe diameter SCT-1 DN50 -40 160~ ℃
Picture Specification Model Meas. Range Temperature Cut off water Accuracy
Model Selection
TS 2--TM 1-TL 1- -TS 2 HT- -TM 1 HT- -TL 1 HT-TC 1-TC 2
G (inline type)
0 Carbon steel Stainless steel1Cast iron2Glass Fiber3
4 PVCCement pipe5Others6
Example: .TUF - 2000F2 - TM - 1 - DN300 - 0 -1 MPa-10m - -6 PCT 1
PS: Fixed mounted ultrasonic flow meter TUF - 2000F2, clamp on transducers TM- 1 , measuring pipe diameter: DN300mm, pipe material: carbon steel, pressure: 1.6Mpa, signal cable length:10m, insertion type heat transducers with pressure PCT-1 for heat measurement.
Flow Measurement Transducers
Pipe Diameter
P/NPipe Material
Cable length
Temperature transducer
None -CT 1
-TC T 1-PCT 1-SCT 1
Data Sheet & Model Selection
Principle
Accuracy
Operation
Output
Input
Pipe Material
Pipe Diameter
Steel, stainless, cast iron ,copper,cement,PVC,aluminum, glass steel,etc.
Data Interface
Item
Converter
Special cable
Pipeline
Measuring Medium
WorkingEnvironment
Power Supply
Power Consumption
Principle & Parameters
Transit-time, 4 byte floating-point operation in accordance with IEEE754
Inline type: flow meter:±0.5%; heat meter: ±1.0%Clamp on type:flow meter:±1.0%; heat meter:±2.0%Insertion type: flow meter:±1.0%; heat meter:±2.0%
4-key manipulation with magnetic bar touch or finger touch; simulation keyboard software
One way 4~20mA analog output,electric resistance:0~1k,accuracy:0.1%
One way Relay output
3 way 4~20mA analog input,accuracy:0.1%;Acquisition signal of temperature,press and liquid level
Achieve heat measurement by connecting 3-wired PT100 temperature transducers
RS485 serial interface,upgraded by computer,support MODBUS communication protocol
Twisted-pair shielded cable and cable length should be no more than 50 m .Transmission distance can achieve 1 km if select the RS 485 interface
DN15mm~DN6000mm
Straight PipelineTransducers installation points should be:10 diameters’ straight pipeline from upstream transducer;5 diameters’ straight pipeline from the downstream transducer;30 diameters’ straight pipeline from the pump
Liquid Type Single liquid that can conduct sound wave, such as water, seawater, sewage, plant effluent, chemicals, alcohol, beer,oil,etc.
Fluid Temperature -30℃~160℃
Turbidity ≤10000ppm,with little bubble
Fluid velocity 0m/s~7m/s
Temperature Converter:-20℃~60℃; Transducer:-30℃~160℃
Humidity Both of the converter and transducers can work under water, depth underwater ≤2m. (After completely sealing )
DC8~36v; AC85~264V(optional)
1.5W
One way OCT pulse signal output
14 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
Converter Wiring And Waterproof
Whole machine waterproof: TUF-2000F2 ultrasonic flow meter reach IP68 protection class, can work underwater within 2m.
Parts waterproof: all parts are water proof except circuit board and junction box, please seal completely with gel after wiring so that the circuit board and junction box are waterproof, working normally in case of water inside.
TX2
T2
GND
T1
T 1X
A 5I
A 4I
A 3I
OCT-
OCT+
RLY-
RLY+
Pls seal w
ith gel after wire connection
GND
D +N
UP-
UP+
AO+
AO-
485-
485+
24V-
24V+
DN-
GND
Relay Output
OCT Pulse Output
Analog Input
Supply Pipe PT100
Return Pipe PT100 Upstream Transducer
Downstream Transducer
Active 4-20mA
RS485 Output
24V Power Supply
1、Wiring Diagram
2、Water Proof
Whole Machine Waterproof Circuit board is waterproof after sealing with gel
15 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
Certification
16 TUF 2000F2- . - .www tuf 2000 comULTRASONIC FLOW/HEAT METER Dalian Taosonics Instrument Co., Ltd.
HeadquarterAdd: South industrial park, Tangligou, Hongqi street, Ganjingzi district, Dalian, Liaoning.Zip code:116021Fax :0086-411-84179900Website: www.tuf-2000.com ; www.t3-1.comEmail: [email protected]