r SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE SOLAR HEATING SYSTEMS SANFORD SILLMAN r-lARCH 1981 PREPARED UNDER TASK No. 1013.00 Solar Energy Research Institute A Division of Midwest Research Institute 1617 Cole Boulevard Golden, Colorado 80401 Prepared for the U.S. Department of Energy Contract No. EG-77-C-01-4042

UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

r SERI/TR-721-907 UC CATEGORY: UC-59a,c

THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE SOLAR HEATING SYSTEMS

SANFORD SILLMAN

r-lARCH 1981

PREPARED UNDER TASK No. 1013.00

Solar Energy Research Institute A Division of Midwest Research Institute

1617 Cole Boulevard Golden, Colorado 80401

Prepared for the U.S. Department of Energy Contract No. EG-77-C-01-4042

Page 2: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

Printed in the United States of America Available from: National Technical Information Service U.S. Department of Commerce 5285 Port Royal Road Springfield, VA 22161 Price:

Microfiche $3.00 Printed Copy $7. 25

NOTICE

This report was prepared as an account of work sponsored by the United States Govern­ment. Neither the United States nor the United States Department of Energy, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or 9,SSumes any legal liability or responsibility for the accuracy, completeness or usefulness of any information, apparatus, product or process disclosed, or represents that its use would not infringe privately owned rights.

Page 3: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S;::~I I~I--------------------~----------------------------------------

PREFACE

This document is part of a coordinated effort at the Solar Energy Research Institute (SERI) to examine all aspects of energy storage technologies with applications in solar systems. A comprehensive study is presented of the performance of active solar space and water heating systems with inter­mediate and annual-cycle thermal energy storage. A unique feature of this report is the investigation of systems used to supply backup heat to passive solar and energy-conserving buildings, as well as to meet standard building loads.

The author extends his appreciation to Frank Baylin, who supervised the research leading to this report and provided valuable advice in its prepara­tion, and to Michael Holtz, David Claridge, and Charles Wyman who crit­ically reviewed this work.

Sanf ord Sillman

Approved for

SOLAR ENERGY RESEARCH INSTITUTE

Michael J. H tz, Chiff Building Syst ms Deyelopment Branch

/ (.~W~

J. ichael Davis, P.E., Manager Buildings Division

iii

Page 4: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

/.=, TR-907 S=~I 11.11 --------------------------------~ ~~

SUMMARY

OBJECTIVE

Develop a comprehensive understanding of the performance of active solar heating sys­tems with intermediate and annual-cycle storage.

DISCUSSION

A daily-step computer simulation is used to determine the performance of solar heating systems as collector and storage size is varied. Simulations are performed for systems in four cities in the United States: Boston, Mass., Medford, Oreg., Bismarck, N. Dak., and Albuquerque, N. Mex. The study assumes various building load types and includes both flat-plate and evacuated-tube collectors at different tilt angles, and single-tank and two­tank systems. A unique feature of this study is the investigation of systems used to pro­vide backup heat for passive solar and energy-conserving buildings and to meet standard building loads.

CONCLUSIONS AND RECOMMENDATIONS

System performance is found to increase linearly as storage size increases up to the point where the storage tank is large enough to store all surplus heat collected in summer. This point of unconstrained operation represents the optimum design for annual storage systems. Only a moderately-sized storage tank is needed for these systems if building loads have been reduced by conservation. In contrast to diurnal storage systems, annual storage systems show only slightly diminishing returns as overall system size is increased. Annual storage systems providing nearly 100% solar space heat may be eco­nomically preferable to the more common 50% solar heating systems with diurnal stor­age. Also, in contrast to diurnal systems, annual storage systems perform well in meet­ing the load of a passive solar or energy-efficient building. Economic analysis is based on the net energy added by the inclusion of annua~ storage in the solar heating system. This net added energy is found to be 1~0-2l0 MJ/m -yr, depending on location and load type. An assumed storage cost of $30/m is equivalent to a fuel price of 4~6~kWh. The entire system is found to be equivalent to a current fuel price of 4~9tVkWh.

v

Page 5: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~I TR-907

1.0

2.0

3.0

4.0

5.0

6.0

TABLE OF CONTENTS

Introduction •• ........................................................ 1.1 1.2

Overview ....................................................... . Functioning of Seasonal Storage Systems

Method of Study ...................................................... 2.1 2.2 2.3 2.4 2.5 2.6

Location .............................. . Flat-Plate Versus Evacuated-Tube Collector Collector Tilt ........................................... . Bull ding Typ e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nature of Building Load ........................................... . Building Design and Extent of Conservation ••••••.••••••••••••••.•••••

Restll ts .•...••••••••••••.

3.1 3.2 3.3

3.4 3.5 3.6 3.7 3.8

System Performance ••...•.••.......••••.••......•........... N ear-l 00% Solar Systems ......................................... . Space Heating Systems ............................................ . 3.3.1 Net Added Energy and Collector Type •••••.•••••••••••••••.•••• 3.3.2 Standard, Passive, and Superinsulated Construction ••••••..•••••• 3.3.3 Performance Variation by Location ••••••••••.••••••••••••••••• Hot Water Systems ............................................... . Combined Heating and Hot Water Systems ••.••••.•••••••••••••••••••• Single-Unit Systems .............................................. . Eff ect of Collector Tilt ........................................... . Two-Tank Systems ............................................... .

System Economics.

Design Methods

Conclusions .......................................................... 7.0 References .............. . . ..................................... . Appendix A Basic Assumptions on the Solar Heating System

Appendix B Calculation of Passive and Conserving Building Loads

Appendix C Simulation Results

vii

Page

1

1 1

7

7 7 7 7 8 8

9

9 15 17 22 22 25 26 27 31 31 33

37

41

43

45

47

49

57

-""'---1

Page 6: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

'" TR-907 S=~II.I ------------------------------- ~~

UST OF FIGURE;

1-1 Profile of Monthly Load and Solar Collection for an Annual Storage System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

1-2 Monthly Collector Efficiency and End-of-Month Storage Temperature for Diurnal and Annual Storage Systems.. . . . . . • • • • . • • • • • • . • 3

1-3 Schematic of Two-Tank Annual Storage System .•....•••••••......•...•.• 5

1-4 Monthly Efficiency and End-of-Month Temperature for a Two-Tank Annual Storage System .............................................. 6

3-1 System Performance and Collector Storage Trade-Off Curves for a Typical Annual Storage System. . •• . . •• •. •• . • .. . . . . • . . . • • . • .. . .• .•. .• 10

3-2 Slope of Performance and Trade-Off Curves in Figure 3-1 ••••••••••••••.•• 12

3-3 Economic Optima in a Region with Linear Design Trade-Off 13

3-4 Performance of an Annual Storage System with a Large Hot Water Load .••....•.•..••••.•..........•.•••••....•.....••••......•. 14

3-5 Efficiency of Diurnal Solar Systems Versus Solar Fraction.. . . •. .•. . . . . . . • • 16

3-6 Efficiency of Annual Storage Systems Versus Solar Fraction................ 18

3-7 System Cost per Unit Heat Delivered Versus Solar Fraction for Space Heating Systems .•••....•.....••.•....•......•.•..• 19

3-8 Efficiency Versus Solar Fraction for Combined Space Heat and Hot Water Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

3-9 System Cost Versus Solar Fraction for Combined Space Heat and Hot Water Systems. • • • . . . . . • . . . . . • . . . . . . . . . . . . . . • . • • . • 21

3-10 Monthly Load for Different Building Designs... . . . .••. .• • • •. • • • . • . . • .•. . . 23

3-11 Performance of Annual Storage Systems with Standard, Passive, and Superinsulated Load Types ••••••••••••••••••••••••••••••••••••••••••• 24

3-12 System Performance with Varying Collector Tilt......................... 32

3-13 Monthly Efficiency and End-of-Month Storage Temperature for a Dual-Use, Two-Tank System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

viii

Page 7: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

= TR-907 S::~I'~I--------------------------------------------------------~-----~ ~~~

LISl' OF TABLES

3-1 Comparison of Space-Heating, Hot-Water, and Combined System PerformBIlce .•••.•••••••.•.•...••.•••..••••••........•.•••••. 28

4-1 Life Cycle/Break-even Energy Cost of Annual Storage Systems. . . . . • . . . • • . . • 39

ix

Page 8: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~IW - IlIglll - ~

x

Page 9: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

,,=, TR-907 S=~III.II --------------------------------~ ~

SECTION 1.0

INTRODUCTION

1.1 OVERVIEW

Active solar energy is the major alternative heat source for building applications for which passive solar energy is unsuited or limited in its application. Active solar energy uses include hot water, space heat for residential, commercial and industrial buildings, backup heat for houses using passive solar heat in northern locations, and retrofit appli­cations. The technical performance of active solar systems is limited by seasonal weather patterns. Because summer, the season of maximum sunlight, is also the time of minimum heat demand, active solar systems must either be undersized in meeting the load or sit idle during a large part of the year. In addition, backup energy is required during cloudy periods.

The use of annual storage both improves the technical efficiency of active solar systems by allowing collection of solar heat in summer and extends the capability of active solar systems to meet nearly 100% of the load. Annual storage systems rely on a large storage tank, usually with water as the storage medium. The storage tank is charged fully during summer, and the stored heat then is used to help meet the winter load. In addition, col­lection of solar heat continues during the winter, and the annual storage tank is used for day-to-day storage. The winter load, thus, is met partly by day-to-day collection of solar heat, as in a conventional active solar heating system, and partly by stored heat from the summer.

This work presents a comprehensive study of the design trade-offs in annual storage sys­tems-particularly the trade-off between collector and storage size. A unique feature of this study is the investigation of systems with several types of building loads, including both space heat and hot water loads, and various conservation measures. Also included is a study of "hybridll buildings that include both passive solar design and active solar heat­ing with seasonal storage. Previous work in the field has been limited by the locations examined, collector type used, or extent of the design trade-offs considered (McGarity 1979; Baylin and Sillman 1980; Braun and Duffie 1979).

1.2 FUNCTIONING OF SEASONAL STORAGE SYSTEMS

The operation of seasonal storage systems can be understood by examining the annual building load and solar collection pattern (Fig. 1-1). Without seasonal storage, the sys­tem referred to would dump excess heat throughout the summer months and require backup heat to meet the difference between solar collection and building load in the win­ter months. Adding an annual storage tank would enable summer excess to be stored and used to provide winter backup. The necessary amount of annually stored heat is deter­mined by the seasonal variation in load and solar heat supply.

While adding an annual storage tank to a system has the primary effect of matching the seasonal pattern of the heat supply with the load, it also has a secondary effect of reduc­ing collector operating efficiency for large parts of the year. Figure 1-2 illustrates the difference in operating efficiency between an annual storage system and the equivalent active solar heating system with daily storage. Throughout the fall and winter, annual storage systems operate at higher temperatures and lower collector efficiency than

1

Page 10: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~II.I ------------------------------~ ~~

.,.

500

- 400 Load -, '" 0 ,.... >-

Collected Solar Cl ~

(]) Energy c: LU 300 ~

C'Cl -0 (J)

"0 (]) -(.) ~ 200 -0 0 "0 c: C'Cl

"0 C'Cl 100 0 ..J

A M J . J A S a N D J F M

Month

Figure 1-1. Profile of Monthly Load and Solar Collection for an Annual Storage System System is designed to provide space and water heat for a 50-unit district of apartments in Boston, Mass. System uses flat-plate collectors. Data are all based on computer simulations.

2

Page 11: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~II.' ______________________ ......:T:...::.R.:.....-..:..90::....;,.7 -~ ~~

>. u c: Q)

·0 ,:;: -UJ

c: 0

:;:; u ~ "0 ()

-() 0 ---Q) '-:J -(\I '-Q) a. E Q)

I-

0.5

0.4

0.3

0.2

0.1

80

70

60

50

30

A M J J

Month

(a) System Efficiency

SONDJFM

Month

Annual Storage

Diurnal Storage

Diurnal Storage

Annual Storage

(b) End-of-Month Storage Temperature

Figure 1-2. Monthly Collection Efficiency and End-of-Month Storage Temperature for Diurnal and Annual Storage Systems Systems are designed for Boston, Mass., using flat-plate collectors.

3

Page 12: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

h; TR-907 S=~I'I.' -------------------------------- ~~~

systems with daily storage. Only in the spring and summer, when energy is not needed, does the collector efficiency of the annual system exceed that of the system with daily storage [see Fig. 1-2(b)]. Other effects of seasonal storage include greater storage losses and decreased day-to-day variation.

The reduction in efficiency with annual storage systems may be avoided by using a two-tank system, developed by Cha et ale (1979). This system operates with two storage tanks, one sized for daily storage and one sized for annual storage, enabling the system to store extra heat in the annual storage tank and simultaneously collect and use low-temperature heat during the fall and early winter. Figures 1-3 and 1-4 illustrate sys­tem operation and efficiency of the two-tank system, which combines advantages of both daily and annual storage systems.

4

Page 13: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

Annual Storage

Diurnal Storage

Figure 1-3. Schematic of Two-Tank Annual Storage System

Hot Water Load

Page 14: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~II_I ---------------------------~-

O.S .... -----------.....

>. ./ C,)

0.3 c: .~ I C,)

;;:: -UJ

0.2 I I

\ I I

0.1 ,

_./ Single-Tank

System

Month

80

-U ~ 70 Q.l .... :::l

til 60 .... Q.l Q.

E SO Q.l I-

40

30

20 0 J F M

Month

Figure 1-4. Monthly Efficiency and End-of-Month Storage Temperature for Two-Tank Annual Storage System System is for flat-plate collector system, Boston, Mass., with standard load.

6

Page 15: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 5;::~I'~'---------------------------------------------------------------~ ~

SECTION 2.0

METHOD OF STUDY

This study is based on a daily-step simulation described in a previous publication (Baylin and Sillman 1980). The basic assumptions of this model, including collector performance parameters, are presented in Appendix A. Selection of a simulation with daily steps enables systems with small- and intermediate-sized storage tanks to be included in the study.

System designs are compared for a number of different locations, collector type and tilt, building types, and building design. The following subsections describe the major design variables included in the study along with notes concerning the significance of each.

2.1 LOCATION

Four locations were selected: Boston, Mass.; Albuquerque, N. Mex.; Bismarck, N. Dak.; and Medford, Oreg. Boston was selected to typify the moderate, humid climate of the northeastern and midwestern United States. Albuquerque is representative of the sun­belt, the region of the United States that is most favorable to solar applications. Bis­marck and Medford were selected to represent climates suitable for annual storage­Bismarck because of its severe winters and Medford because of its winter rainy season.

2.2 FLAT-PLATE VERSUS EVACUATED-TUBE COLLECTOR

The choice of collector type affects the performance of annual storage systems through its effect on collector efficiency. Evacuated-tube collector efficiency changes little as collector operating temperature changes, while flat-plate collectors show much greater swings in efficiency. This difference affects the choice between diurnal (daily) and annual storage in two ways. Evacuated-tube collectors permit greater collection of solar heat during winter when climatic conditions are worse, thus improving the performance of diurnal storage systems and lessening the need for annual storage. On the other hand, use of evacuated-tube collectors eases a major problem of annual storage systems: reduced collector efficiency due to higher operating temperatures.

2.3 COLLECTOR TILT

Two collector tilts are used, one equal to latitude and one equal to latitude plus 10 degrees. The sharper tilt favors solar collection in winter, while the less sharp tilt favors spring, summer, and fall collection. Collectors with the sharper tilt perform bet­ter for nearly all systems, while collectors with the less sharp tilt are most advantageous for systems with very large storage. Unless otherwise specified, system sizing and per­formance described in this study all have a collector tilt of latitude plus 10 degrees.

2.4 BUILDING TYPE

Four building configurations are modeled: single-family houses with a 50-unit district heating system, individual single-family houses, 10-unit apartment buildings with a

7

Page 16: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S;::~I 1~1 ________________________________________________________ T_R_-_9_0 __ 7 - ~~

50-mit district heating system, and 200-mit apartment buildings. These configurations are referred to in this work by the abbreviations SUB 50, SUB 1, TUB 50, and HUB 200, respectively. Building types were selected to be consistent with a previous study (Baylin 1980a). The building type affects system performance by changing the ratio of space heat load to hot water load and also by changing the proportion of heat lost from storage.

2.5 NATURE OF BUILDING LOAD

Included are systems for space heating only, systems for hot water only, and combined space heat and hot water systems. For combined space heat and hot water systems, the ratio of space heat to hot water load is varied among the four building types.

2.6 BUILDING DESIGN AND EXTENT OF CONSERVATION

Three basic building types are included: standard construction, passive design, and super­insulated design. The space heat loads are calculated by using an algorithm for calculat­ing day-to-day building loads (see Appendix B). Key param eters in describing the building load are (1) gross shell loss, (2) miscellaneous heat gain, and (3) passive heat gain. Tables B-1 and B-2 in Appendix B present these values along with final yearly loads for all build­ing types.

The standard building loads are found by using the degree-day method, with a miscellane­ous heat-gain equivalent of 1.5°C temperature difference. Miscellaneous heat typically provides 10% of the total yearly heat load in this instance. The passive designs include reduced gross shell load and passive gain designs in which miscellaneou~ heat provides 15%-20% of the gross shell load and passive solar heat provides 40%-50% of the gross shell load. The remainder is provided by the active system.* Superinsulated houses rep­resent a relatively new building concept (Shurcliffe 1980). These are houses built for northern climates with very well-insulated walls [20-30 cm (8-12 in.)] and nearly airtight construction. Typically, miscellaneous heat provides a significant fraction of the gross shell load, which is already reduced far below that of a standard house by insulation. Designs used here had 35% of the gross shell load provided by miscellaneous heat and 35% by passive gain. Both passive and superinsulated designs are assumed for houses and small apartment buildings. High-performance passive systems for large buildings may be more limited than for small buildings, because of heat distribution problems. Conse­quently, only two designs are used for large apartments: a standard design and a con­serving design in which miscellaneous heat and passive gain supply 30% and 25% of the gross shell load, respectively.

The variation in building design affects annual storage system performance in many ways: 'the shape of the annual load is changed; the pattern of day-to-day variations is changed, often to the detriment of the performance of active solar systems; and the rel­ative sizes of the space heat and hot water loads are changed. The load sizes are of par­ticular importance. In buildings of standard design, loads are equal; with superinsulated design, the hot water load is frequently greater.

*In Albuquerque, N. Mex., passive design was found by simulation to meet over 80% of the building load. Superinsulated houses were not investigated for Albuquerque.

8

Page 17: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

/. "', TR-907 S;::~I I~I--------------------------------------------------------------

SECTION 3.0

RESULTS

3.1 SYSTEM PERFORMANCE

The performance of solar heating systems with long-term storage may be evaluated in two ways. The first method is to examine system performance with varying storage size while collector area is held constant. A plot of performance versus storage size shows the performance gain attributable to long-term or annual storage. The second method is to plot the trade-off between collector and storage size while assuming system perfor­mance will remain constant. The trade-off plot is akin to the standard economic tech­nique of plotting performance isoquants in a resource space. Taken together, the system performance and collector/storage trade-off plots provide a complete picture of sizing options for solar heating systems with long-term storage.

Figure 3-1 shows the performance and trade-off plots for a typical annual storage sys­tem. The patterns shown in Fig. 3-1 permit the identification of three regions with dif­ferent performance characteristics: a diurnal and weekly storage region (Region A in the graphs), an intermediate region (Region B), and an annual storage region (Region C). In the diurnal storage region, the storage tank provides day-to-day or week-to-week stor­age, and the system performance curve slopes sharply upward. In the intermediate stor­age region, system performance improves steadily with storage size because the amount of heat stored from summer to winter increases. The upper bound of Region B represents annual storage at the point of "unconstrained operation" (Hooper and Cook 1980). At this point, storage is just large enough to store all heat collected during the summer months without exceeding its allowed maximum temperature. Larger storage tank sizes (Region C) would provide no extra storage capacity, although they do improve collector efficiency by lowering system operation temperatures. The pattern of the three regions is shown more clearly in Fig. 3-2, which plots the slopes of the performance and trade­off curves in Fig. 3-1. Figure 3-2 shows that the performance and trade-off curves vary linearly throughout the intermediate region, up to the point of unconstrained operation.

Because of the linear pattern of the performance and trade-off plots, the point of uncon­strained operation is the only likely economic optimum. As illustrated in Fig. 3-3, the optimum will occur at either the lower or the upper bound of a region of linear system performance, but not at an intermediate point. In practice, intermediate optima can occur because the performance curves are not perfectly linear. These intermediate optima are rare, however, and represent at best a slight savings over diurnal or annual storage systems. It may be assumed that optimal systems will be either annual storage systems near the point of unconstrained operation or diurnal storage systems.

The same pattern is repeated for each system investigated in the study. The system per­formance and collector/storage trade-off plots, shown in Appendix C, all follow a linear pattern bounded by the points of unconstrained operation. Consequently, unconstrained systems represent the only possible long-term storage optima. Note, however, that unconstrained systems do not always have the large storage tank sizes that are commonly associated with the term "annual storage." A s~stem th~t provides only space heat may have a storage-to-collector ratio as high as 5 m to 1 m . A system t~at also P20vides a large hot water load may have a storage-to-collector ratio of 1 m to 1 m or less (buffer storage) and still be at the point of unconstrained operation. Such a pattern is illustrated in Fig. 3-4. These buffer storage systems are used when the need for

9

Page 18: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

...... o

c o :g al

1.0

0.£

0.8

U: 0.7 Ui OJ I .....

..!!! o (f)

Region C

0.6 Collector Areas (m2)

Region B

0.5

Region A 0.4

0.3L---------~----------~----------~----------~--------------------~ 0.0 1.0 2.0 3.0 4.0 5.0

Storage to Collector Ratio (m3/m2)

(a) System Performance

Figure 3-1. System Performance and Collector Storage Trade-Off Curves for a Typical Annual Storage System System is for a Boston, Mass., SUB-50, standard space heat load, using flat­plate collectors. The dotted lines separate regions A, B, and C defined in the text.

6.0

III III ;U -'.' ~~!?-

Page 19: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

I-' I-'

11250----------------------------------------------------------------------------~

9000

E 6750 (1) N

Ci5 .... o (3 ~ o o 4500

2250

0

I

I /

0

Region A

I

---

I I

--

I

I I

--

Region B

--

./ /'

/' /'

/'

/'

./ ./

./ ./

,,/ Region C

0.99

0.85 0.90

Solar Fractions

2250 4500 6750 9000 11250 13500

Storage Size (m3)

(b) Collector-Storage Trade-Off

Figure 3-1. System Performance and Collector Storage Trade­Off Curves for a Typical Annual Storage System' (Continued)

0.95

15750 18000

Page 20: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

5=~1'*' ______________________________ T_R_-_9_0_7

'" o ,.... ai_ l::: 0) :::l Ol o e 0) 0 QU) c: >­(1:l..a

E-o o 0) 't:-o 0)"0 a.. (1:l

E ~ 0)­..... (1:l 00> >--

C/) -o 0) a. o

C/)

-'"' E --.... '" E - -- 0) 00l

I (1:l 0) ... -00 (1:l ...... ... 00 I- ... 0).2 Ol ... (1:l 0 ........ o Q ..... 0) C/)= ... 0 o Q ..... Q-0) 0 = c: o 0 0:;:; _ :::l

0:::: ...... 0) 00 a...a o :::l

- 00 C/)_

0 0) ...... (1:l

cr:

Region A. 500

Region B. Region C 400 -

300

200

100

1.25

1.0

0.75

0.50

0.25

2 3

Collector Area 2800 m2

4 5

Storage to Collector Ratio, m3/m2

(a) System Performance

I I I I I I I I I

Region A I Region B I

2000 4000 6000

Storage Volume (m3)

(b) Collector/Storage Trade-Off

Solar Fraction 0.95

Region C

8000 10000

Figure 3-2. Slope of Performance and Trade-Off Plots in Figure 3-1 (Slope of Figure 3-1 (a) has been converted to energy units.)

12

Page 21: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

!s::~1 I~I ____________________________________________________________________ ~T~R~-~9~O~7

Resource B

---- -- - Cost Isoquants

® Economic Optimum

Performance Isoquants

\

~ \ ... , ::::l , o , (/) , Q) ,

a: \

(b)

,

\

\ , ,

, ,

\ , ,

\ ,

\ \ ,

\ , \

\ \

\

,

\ \

\

\

, , , , \

, \

\

,

\ \ , ,

\ \

\ , , , , \

\ \

\ , \

\ \

\

\ ,

\

\ \

\ \

\

\ ,

\

\ \

Resource B

, , \ , ,

\ \ ,

Figure 3- 3. Economic Optima in a Region with Linear Design Trade-Ofts Plots (a) and (b) assume different unit costs for resources.

13

Page 22: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~II.I ___________________________ ..::.T..::.R=-.-..::.9.::..07.:..

-~ {o.~

1600

1200

800

I I

400 I

I

Region A. /

400 800

Region B.

1200 1600

Storage Volume (m3)

Region C.

0.90

0.85 0.80

0.75

2000

Solar Fraction

0.95

Figure 3-4. Performance of Annual Storage System with a Large Hot Water Load System is a two-tank system with flat-plate collectors for Boston, Mass., with a SUB-50 superinsulated load. Hot water accounts for 60% of the annual load.

14

Page 23: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S;::~II~I--------------------------------------------------------------- »~~

seasonally stored heat, as indicated by the summer-to-winter load variation, is relatively small. Although the amount of stored heat is less, these systems show the same operat­ing characteristics (performance curves, month-to-month storage temperature, etc.) as do larger annual storage systems.

The conclusion that only unconstrained systems are worthy of consideration greatly sim­plifies the job of systems analysis. The key parameters for system evaluation are the slopes of the system performance and collector/storage trade-off curves. The slope of the system performance curve represents the increase in supplied energy resulting from an increase in storage size. This parameter will be referred to as the "net energy added by storage" and will be expressed in energy lIDits per cubic meter. Theoretically, the net energy added by annual storage is at most equal to the amount of heat stored over the annual cycle. Based on a 4SoC storage

3temperature swing over the annual cycle, the

maximum net energy added is 200 MJ/m . per year. The net energy added by storage is used to determine whether annual storage is preferable to a system with smaller storage and greater reliance on backup power.

The slope of the collector/storage trade-off curve gives the rate at which collector size (in square meters) may SUbstitute for storage (in cubic meters) if

2sysjem performance is·

to remain the same. This trade-off parameter, expressed in m /m , is used to choose between annual storage and diurnal or weekly storage systems once a given level of sys­tem performance is specified. A large trade-off parameter means that a large collector size may be replaced by a given increase in storage. Consequently, a larger trade-off parameter favors annual storage systems over a diurnal or weekly storage system that provides the same solar fraction.

Appendix C presents complete results of the systems study. The tables in Appendix C give the following information for each system design:

• Collector and storage size for the point of unconstrained operation;

• Net energy added by storage and collector/storage trade-off, explained above;

• Solar fraction (i.e., the percentage of the total building load met by solar heat); and

• Diurnal solar fraction. This is the solar fraction of an identical system without annual storage, assuming the annual storage tank is replaced by a diurnal tank. The diurnal solar fraction indicates how significant the annual storage component is to the system.

3.2 NEAR-IOO% SOLAR SYSTEMS

In the preceding section, the concept of unconstrained operation was developed as a cri­terion for the optimal sizing of annual storage systems. This criterion may be used to size annual storage systems once the solar heat fraction is chosen. In this section, the choice of solar heating fraction will be examined in detail.

Active solar systems with diurnal storage typically show diminishing returns as the sys­tem size is increased to meet a large percentage of the load. Figure 3-5 shows how system efficiency* decreases for larger diurnal systems, for both space heat and hot

*System efficiency is defined as the annual amount of heat delivered to the load divided by the total yearly insolation incident on the collector surface.

15

Page 24: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S::~II~I--------------------------------------------------------~~~ -~ -~~

0.50

0.25-

>-()

0.20 c .~ () ;;:: -LU

E 0.15 CD -en >-

C/)

0.10

Hot Water Load

0.2 0.4 0.6 0.8

Solar Fraction

Figure 3- 5. Efficiency of Diurnal Solar Systems vs. Solar Fraction System for Boston, Mass., a SUB-50, flat-plate collector system.

16

1.0

Page 25: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~II.I ______ -,-__________________ ---"T:..;::R.;;..-...;;.9..;;..0-'-7 -~ ~~

water. As one approaches 100% solar heat, collector size increases and the collector stands idle for much of the time, especially in summer. Cost curves for diurnal systems typically pass through a clearly defined minimum at a solar fraction of 40%-70%. Furthermore, Fig. 3-5 shows that diurnal systems function poorly when added to an energy-conserving building.

Annual storage systems show much less of a tendency toward diminishing returns as the solar fraction is increased. Figure 3-6 shows the efficiency of unconstrained annual stor­age systems versus solar fraction for systems supplying space heat only. Returns are slightly diminishing when the solar fraction approaches 100%.

Figure 3-7 presents the same data in terms of cost. Cost figures are calculated as the sum of collector, storage, and fixed costs (Baylin et al. 1980b) for optimally sized diurnal and annual storage systems. The curves for diurnal storage systems show the standard pattern of a cost minimum at a solar fraction of 50%. When annual storage is con­sidered, however, cost either decreases or remains constant as the solar fraction increases to 100%. The most cost-effective solar option would therefore be a system designed to meet 90%-100% of the load, not 40%-60% as is commonly assumed.

When an annual storage system provides hot water as well as space heat, there may be more of a tendency toward diminishing returns. Such systems typically must be large enough to provide 80% of the hot water load before any seasonal storage effect occurs. As shown in Fig. 3-8, small diurnal storage systems that provide predominantly hot water have a much higher efficiency than annual storage systems. As system size is increased, collector efficiency drops steadily until the collector field becomes large enough to per­mit annual storage. Efficiency then remains constant for all annual storage systems sized at the point of unconstrained operation.

Combined system cost is plotted against solar fraction in Fig. 3-9. The pattern shown is one of two economic optima, a diurnal storage optimum and a near-lOO% annual storage optimum. The component costs will determine which of these optima will be less expen­sive. For the prices assumed here, the annual storage-system energy cost is virtually equal to the optimal diurnal system cost. Consequently, a near-100% system will be the most cost-effective option whenever fuel costs are high enough to favor active solar heating.

The near-lOO% optima for annual storage systems shown in Figs. 3-7 and 3-9 are not accidental. Because annual storage systems show near-constant returns as solar fraction increases, near-lOO% systems are the likely optim um if annual storage is used at all. The design criteria for annual storage systems is now complete. Optimal systems will be those designed at the point of unconstrained operation and supplying a large percentage (90% or higher) of the given load. The remainder of this study will examine the perfor­mance and economics of annual storage systems in specific applications. Annual storage system sizes will all reflect these design criteria.

3.3 SPACE HEATING SYSTEMS

Systems designed for only space heating are much simpler than combined space and water heating systems. Although combined space and water systems are generally preferable, space heating systems have applications in commercial buildings that have zero or negligible hot water load.

17

Page 26: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~II_I ------------------------------=-==-~

>. u c Q)

·0 :;:: W E Q)

U; >.

CI)

0.50

0.40

0.30

0.25

0.20

0.15

0.10

0.05

~Load ----------- ----------~

0.2 0.4

Superinsulated Load

0.6

Solar Fraction

~

0.8 1.0

Figure 3-6. Efficiency vs. Solar Fraction for Annual Storage Systems (Space Heat Only) Systems for Boston, Mass., SUB-50 with flat-plate collectors. All systems are sized near the point of unconstrained operation. Storage size is roughly proportional to collector size for these systems at a ratio of 3 mJ : 1 m2 •

18

Page 27: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~I :~~I ______________________ --.:T:...:R~-..::...90:::..:.7

-'->. ...... ~

'" 0 .... ...... ~ -en 0 0

400

300

'- .... -................... - - -_ .... "

Passive Load

, Standard

" ","

" Load ...... '" , .... '" '- _ .... --.......:::....---

/ ./

/'

/ /

- - - ~ Optimal diurnal storage systems

-- Optimal annual storage systems

O~--~~----~~----~~----~~----~~ 0.2 0.4 1.0

Solar Fraction

Figure 3-7. System Cost per Unit Heat Delivered vs. Solar Fraction for Space Heating Systems. Systems are for Boston, Mass., with flat-plate collectors, for a 50-unit district of single-family houses. Cost is the sum of the collector cost at $140Im2; storage cost according to the equation Cs = 385 x [Vol (m3)]072; and the fixed cost. Fixed cost is set equal to $200,000 per standard, $120,000 for passive construction. All costs are in 1979 dollars.

19

Page 28: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~II.I _______________________ T::....:R;.,:,...-~9~07 -~ ~~

>. () c: Q)

() ;;::: -UJ

E Q)

Ui >.

Cf)

0.5

0.4

0.3

0.25

0.20

0.15

0.10

0.05

Diurnal Systems

Superinsulated Load

'. Annual Systems

Passive '" Load ".

Standard Load

" '. " "'-. , " , .

" ". , '. " '. , '. "'"---~-~------, ~.-.----.--.... ~ .... " " --.~:---- .... ......

0.2 0.4

Standard Load

Passive Load Superinsulated Load

0.6

Solar Fraction

0.8 1.0

Figure 3- 8. Efficiency vs. Solar Fraction for Combined Space Heat and Hot Water Loads Annual storage systems are sized for the point of unconstrained operation. Annual storage size varies greatly, increasing at larger solar fractions. Diurnal storage systems are used when annual storage is not feasible. Systems are for standard, passive, and superinsulated SUB-50 loads, with flat-plate collectors, Boston, Mass.

20

Page 29: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 s=~111i1 ---------------------------------

'C"

<' -, a> 0 .... ...... ~ -(/) 0 ()

500 f-

400 "-

300 -

200 -

100 -

o Separation between optimal diurnal systems (lower solar fractions) and optimal annual systems (higher solar fractions)

\ \ \ \ \

\ \ '\

'. '.

, ,

......

'"

--Standard Load _._. Passive Load

- - - Superinsulated Load

, .. " .f)------......... .. ---.....·0_._ ... -_.,.,' ---.-.-_ ..... -

O~------~~I------~I~----~~I------~I~------~I~ 0.2 0.4 0.6 0.8 1.0

Solar Fraction·

Figure 3-9. System Cost per Unit Heat Delivered vs. Solar Fraction for Combined Space Heat and Hot Water Systems

Systems are for Boston, Mass., SUB 50, with flat-plate collectors as in Figure 3-14. Cost is the sum of collector cost at $140/m2, storage cost according to the equation C s = 385 x (Vol. (m3»O.72, and the fixed cost. Fixed cost is set at $200,000 for standard, $150,000 for passive, and $120,000 for superinsulated construction. All costs are in 1979 dollars.

21

Page 30: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

/.~, TR-907 S=~I".II --------------------------------~ ~

Space heating systems were analyzed for a 50-tmit district of single-family houses including standard, passive, and superinsulated house designs. It is anticipated that building loads for apartments and commercial buildings are similar to the single-family house load and that annual storage systems would thus show similar characteristics. Complete results of simulations are presented in Appendix C.

3.3.1 Net Added Energy and Conector Type

When evacuated-tube collectors arg used, the net energy added by storage is close to the theoretical maximum of 200 MJ/m • With flat-plate collectors, the net energy added by storage is significantly less. When a two-tan~system is used with flat-plate collectors, the net adde~ energy may be 150-180 MJ/m ; with a single tank, the net energy is 130-160 MJ/m. The net added energy also shows greater variation among different locations and building types when flat-plate collectors are used.

The net added energy is affected most by the collector operating efficiency. As described in Sec. 1.0, collector efficiency tends to be lower in annual storage systems, as opposed to diurnal systems, during the fall and early winter months. When evacuated­tube collectors are used, this drop in efficiency is slight and net added energy remains high. With flat-plate collectors, particularly in single-tank systems, collector efficiency is more sensitive to the collector operating temperature and the efficiency drops sharply in fall and early winter. This loss in efficiency is enough to lower the net energy added by storage.

3.3.2 Standard, Passive, and Superimulated Constructioo.

Passive and conserving building designs have two major characteristics that affect the design of an active solar system for backup heat. First, the annual shape of the passive and superinsulated building load is different from the load of a standard building. Passive buildings rarely need additional heat during spring and fall and, consequently, their yearly load occurs within three or four months. A standard building design requires heat in all but the summer months (see Fig. 3-10). A second difference is that day-to-day variations in load are relatively small for a standard building, reflecting only day-to-day changes in temperature. For a passive or superinsulated building, however, the day-to-day load is much more sporadic with no heat required on sunny days even in the middle of winter.

The effect of building design is greatest for diurnal systems. As shown in Sec. 3-2, diur­nal system efficiency drops when used with a passive or conserving building load. The. poor performance of diurnal systems may be due either to the yearly load shape or to the greater day-to-day and week-to-week variations in load. The yearly load shape causes the solar collectors to be idle for a large part of the year. The daily load variation ham­pers system operation because maximum solar collection occurs precisely on those days when there is no load for a passive house. Further investigation shows that the monthly performance as well as the yearly performance of diurnal systems is poor. This indicates that the daily and weekly load variation is a primary cause of poor diurnal performance with passive loads, although the uneven yearly load pattern is also a major influence.

Figure 3-11 compares system performance with storage size for the three different building designs. The figure shows that performance drops much more sharply at small storage sizes for a conserving load. This indicates that even a diurnal system requires larger storage when used with a passive or conserving load. Furthermore, the

22

Page 31: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~I IWI ---------------------------==-=-.=...:. -~ ~

300

-...., '" o ,.... -"0 ~ 200

...J

100

-...., '" 0

"0 CI:I 0

...J

SUB-50 Passive Load

700

600

500

400

300

200

100

SUB-50 Standard Load

AMJJASONOJFM

Month

(109 J)

150

100

50

SUB-50 Supe~insulated Load

A MJJ A SONOJ FM

Month AMJJASON OJ F M

Month

Figure 3-10. Monthly Load for Different Building Designs (Boston. Mass.)

23

Page 32: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

~ TR-907 !s::~I'~I----------------------------------------------------------------

c: .2 t) co ...

u.. ... co "0 C/)

1.0

0.95

0.80

0.65

0.50

0.35

Standard Load

..... ' ,...,. Passive Load ,..

.J/ ~ /~ /".r

..r.r" / .... Superinsulated Load /~ ..... -.....

/' _. /" jlr-

/" / . //

/ // / /"

/// //

/ //

/~// / /

/11 1/ 1/ / f

____ Standard Load

_ _ _ _ _ Passive Load

Superinsulated Load

<!) Point of U nconstrai ned

Operation

0.20 '--____ ..L.-____ L....-___ ~ ____ _..I. ____ ~ __

2 3 4 5

Ratio of Storage-to-Collector Size; m3/m2

Figure 3-11. Performance of Annual Storage with Standard, Passive, and Superinsulated Loads Systems are SUB-50, space heat only; with flat-plate collectors, in Boston, Mass. Collector size is the same relative to annual load for the three systems.

24

Page 33: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I "'.~~ TR-907 ::~ r~r--------------------------------------------------------------

performance ctn've with a passive load continues to slope more steeply than the standard system curve for intermediate-size storage. The steeper slope indicates that week-to­week storage may be important for passive load systems.

Because annual storage is large enough to dampen out daily and weekly load variations, the type of building load has a much smaller effect on annual storage systems. Typically, the efficiency of annual storage systems is 15%-20% lower with a passive building load than with a standard load, and 20%-30% lower for a superinsulated load. This drop in efficiency is due to the annual load shape. Since the passive load is concentrated in the winter, yearly storage temperatures must be higher to achieve the same solar fraction as a system with a standard load. The drop in efficiency is significantly smaller when evacuated-tube collectors are used. Because of the more concentrated annual load pat­tern, systems also require a larger storage tank in proportion to collector area when used with a passive or superinsulated load.

Use of passive or superinsulated construction can cause the net energy added by storage to either increase or decrease. The net added energy may increase with passive buildings because storage serves more of a dual purpose, combining daily and weekly with annual storage. On the other hand, the average operating temperature tends to be higher for systems with passive building loads, which causes poorer system performance.

The trade-off parameter is nearly always larger for passive or superinsulated buildings than for standard buildings. This is the result of increasingly poor performance of diurnal and intermediate storage systems at high solar fractions. It often happens that the net added energy is lower for passive buildings (favoring diurnal systems), but the trade-off parameter is also larger (favoring annual systems). This type of pattern occurs because active systems, with or without annual storage, perform more poorly with passive con­struction.

Results of the analysis for systems in B~to~ are typical. Seasonal storage systems have a ratio of storage-to-collector size (m :m ) of 3: 1 with standard construction and 4: 1 with passive or superinsulated constructioo. The same collector array without seasonal storage would provide 60%-66% of the space heat load with standard construction and 42%-50% with pass~ve 30r superinsulated constructioo. The trade-off par

3ameter ranges

from 0.7 to 1.0 m /m for passive loads and from 0.45 to 0.70 m2/m for standard loads. The net energy added storage remains uniform for standard, passive, and super­insulated houses at a fairly high level: 160-210 MJ/m 3 (near the theoretical ~aximum) for evacuated-tube systems and two-tank, flat-plate systems and 140-160 MJ/m for sin­gle-tank, flat-plate collector systems.

3.3.3 Performance Variatim by Locatim

The performance characteristics of space heating systems show some variation among the four locations. lhe net energy added by storage is significantly higher in Medford, reaching 200 MJ/m even for flat-plate collector systems, and is slightly less in Bismarck. The cause of this variation is the climatic pattern in the fall and early winter. As previously noted, the use of annual storage results in a reduction in the winter collec­tion efficiency, and the reduced solar collection counts against the net energy added by storage. In Medford, winter insolatioo is so small that the poor collector efficiency is insignificant. In Bismarck, by contrast, winter insolation is high and reduced efficiency more important.

25

Page 34: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S;::~I ,~, ______________________________________________________ ~T~R~-~9~0~7 - ~~

The trade-off parameter is similar for the three northern cities, indicating that optimi­zation of collector versus storage size is sim~lar"3 In Albuquerque the trade-off param­eter was much smaller, with a value of 0.2 m 1m • This is due to the greater insolation in Albuquerque, which causes the collector to weigh heavier in the trade-off with storage.

The major difference in system design among the four cities was the system size, which was found to be very similar between Boston and Bismarck; storage to collector ratios were the same, and system performance without seasonal storage was equivalent. This apparently reflects the similar climatic pattern of Boston and Bismarck (eastern humid continental climate), despite the fact that Bismarck's winter is much more severe. By contrast, the storage component was much larger in Medford. The equivalent system without annual storage in Medford would yield a solar fraction of only 52%-58% for standard construction and only 25%-30% for superinsulated construction. This is much smaller than the corresponding value fer Boston given in Sec. 3.3.2. The storage-to­collector ratio is correspondingly larger in Medford. In Albuquerque, seasona.l storage was a smaller component than in the other cities, with daily sy~te~s yielding 65%-72%. The storage to collector ratio in Albuquerque was large (4-6 m 1m ), again a reflection of increased insolation in Albuquerque. Annual storage appears to be most useful in loca­tions with sunny summers and unusually cloudy winters (Medford), rather than in places with unusually cold winters (Bismarck).

3.4 HOT WATER SYSTEMS

Seasonal storage tends to have very little usefulness in systems designed to provide hot water only, primarily because of the nonseasonal nature of the hot water load. Although insolation does vary throughout the year, the gain achieved by storing summer heat fer use in winter is more than offset by the loss in efficiency with seasonal storage systems.

A further important factor concerns the nature of hot water systems. The space heat load can be met with heat collected at any temperature above 300 C, but meeting the entire hot water load requires collecting heat at 550 C or more. Low-temperature solar heat can be used as a hot water preheat. This type of system yields sharply diminishing returns as the system size is increased to meet a large percentage of the hot water load. It also provides a natural mechanism for matching load with available energy; a hot water system may provide substantially preheated water in winter and fully heated hot water in summer with the collection of extra heat for seasonal storage.

The slow reaction time of a seasonal storage tank further encumbers a hot water system. When a seasonal storage tank is fully discharged in winter, it may be at a temperature to provide only 50% of the hot water load. With a daily storage system, the tank would heat to 500 or 600 C on sunny days and provide nearly 100% of the hot water load. The sea­sonal storage tank would remain at 300 C and continue to provide only 50% of the load. This behavior becomes a serious drawback in seasonal storage systems designed to meet a large fraction of the load. It also causes the efficiency of hot water systems with annual storage to be much lower than those with diurnal storage.

For these reasons, seasonal storage typically provides zero yield fer hot water systems with a single tank. Use of two diurnal storage tanks alone is found to increase performance by 10%. A two-tank system with seasonal storage does yield some further benefit because the small tank permits both collection and use of low-temperature solar heat in fall and the collection of high-temperature solar heat fer hot water in the

26

Page 35: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

/.- TR-907 S;::~I I~I--------------------------------------------------------------

spring. The net energy added by annual storage is only 70-80 MJ/m3, and it provides at most a 10% improvement in energy yiel~over diwnal two-tank systems. The storage-to­collection ratio is rarely higher than 1 m to 1 m .*

3.5 COMBINED HEATING AND HOT WATER SYSTEMS

Combined systems are more complicated than either space heat or hot water systems. The performance of a combined system is influenced both by properties of space heat systems, in which seasonal storage has an almost constant value, and hot water systems, in which seasonal storage has low value and decreases system efficiency. The most important factors in the performance of a combined system are the sizes of the space heat and hot water loads relative to each other.

Combined systems may be analyzed as though they are two separate systems, one for space heat and one for hot water. Table 3-1 compares combined systems with systems for space heat only. Assuming both systems are annual storage systems designed at the point of unconstrained operation and both systems provide the same percentage of solar space heat, they will have the same storage size. In addition, the difference in collector size between the two systems compares consistently to the collector size of a solar hot water system that would meet the same fraction of the hot water load as does the com­bined system. Typically, the added collector area in the combined system is greater than the size of the equivalent hot water system by about 10%. This difference reflects the loss in efficiency that occurs when an annual storage system is used to provide hot water. With a two-tank system, the extra collector area in the combined system may be either greater or smaller than the size of the equivalent two-tank hot water system. System performance is significantly worse for combined systems in which the hot water load exceeds the space heat load.

Two-tank systems, initially investigated for space heating (Cha et ale 1979), appear to be most useful for combined systems with a large hot water load. For reasons discussed in the previous section, single-tank annual storage systems tend to perform poorly in meet­ing a hot water load. A two-tank system serves a dual purpose here. First, it permits the collection of low-temperature heat during November and December. Second, it may be used to collect high-temperature heat for hot water in March and April when the annual storage tank temperature is too low to provide hot water. This dual-purpose, two­tank system enables an annual storage system to provide both hot water and space heat efficiently.

The net added energy and the trade-off parameter for combined systems may also be compared to that of space heat systems. The net added energy and the trade-off param­eter are the same for two-tank systems as for the equivalent space heat system. For single-tank systems, the net added energy is lower by 10%-2596 when compared to space heating systems. The drop in the net added energy is greater when space heat loads are

*These conclusions are based on the assumption that the daily hot water load remains con­stant throughout the year. There is evidence (Mixon 1976) that daily hot water loads are actually twice as great in winter as in summer. In that case, conclusions would be more favorable to annual storage systems. Th§l net energy added by storage would rise to 90-100 MJ/m in Boston and 120-140 MJ/m in Medford. The net added energy in a com­bined system (see Section 3.5) would be similarly enhanced.

27

Page 36: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I1;,~ = 1.1 TR-907

Table 3-1. COMPARISON OF SPACE-HEATING, HOT-WATER, AND COM-BINED SYSTEM PERFORMANCE

All systems are for Boston, Mass., and use flat-plate collectors. Annual storage systems are all at the point of unconstrained operation. In two-tank systems, the second tank is sized by:

Vs (m 3) = 0.075 Ac (m 2)

* * - Z Z C"I 0 0 E ..... E-< E=: .....- - C) M C)

~ E < < N .....- ~ ..... ~ 00 ~ ~ ~

~ N E-< >t ..... p:: 0 00 < ~ C) E-< ~ ~ E-< Z

:;E C) c.? ::t: < ~ ~ ~ < ~ :: ..... E-< ....:l p:: C) C)

....:l E-< ......

00 0 < ~ >t 0 E-< 0.. 0 ~ 00 C) 00 00 ::t: ~

Standard construction, single-tank system

Combined system 2800 5600 0.77 0.75 0.259 Space heat system 2270 5900 0.77 0 0.266 Hot water system 480 36 0 0.75 0.274

Combined system 3200 7040 0.85 0.77 0.249 Space heat system 2600 7050 0.85 0 0.254 Hot water system 520 39 0 0.77 0.260

Combined system 3600 7920 0.91 0.80 0.235 Space heat system 2900 8100 0.91 0 0.244 Hot water system 580 44 0 0.80 0.242

Combined system 4000 9600 0.98 0.83 0.226 Space heat system 3350 9400 0.98 0 0.226 Hot water system 650 49 0 0.83 0.224

Passive construction, single-tank system

Combined system 1400 2000 0.70 0.78 0.215 Space heat system 760 2200 0.70 0 0.226 Hot water system 520 39 0 0.78 0.254

Combined system 1600 2900 0.83 0.81 0.211 Space heat system 910 3000 0.83 0 0.222 Hot water system 575 43 0 0.81 0.236

28

Page 37: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I * TR-907 - U'.'I - ~~

Table 3-1. COMPARISON OF SPACE-HEATING, HOT-WATER, AND COM-BINED SYSTEM PERFORMANCE (Continued)

* * - Z Z C"l 0 0 E ..... &-< ..... - - 0 &-<

M 0 ~ E < <: N - ~ ..... ~ ~ ~ 00 ~

~ N &-< ~ .....

~ 0 00 < ~ 0 &-< ~ ~

&-< Z ~ 0 0 ::c: < ~ ~ ~ < ~ ~

..... &-< ...:l ~ 0 0

...:l &-< -Cf.l 0 < ~ ~ 0 &-< p." 0 ~ Cf.l C,) Cf.l 00 ::c: ~

Passive construction, single-tank system

Combined system 1800 3600 0.93 0.83 0.203 Space heat system 1040 3600 0.93 0 0.218 Hot water system 625 47 0 0.83 0.224

Combined system 2000 4000 0.98 0.85 0.191 Space heat system 1150 4000 0.98 0 0.210 Hot water system 670 50 0 0.85 0.212

Superinsulated construction, single-tank system

Combined system 700 600 0.75 0.82 0.198 Space heat system 250 700 0.75 0 0.193 Hot water system 390 30 0 0.82 0.230

Combined system 800 800 0.85 0.84 0.184 Space heat system 300 840 0.85 0 0.183 Hot water system 420 31 0 0.84 0.218

Standard construction, two-tank system

Combined system 2800 5600 0.79 0.86 0.274 Space heat system 2200 5500 0.79 0 0.279 Hot water (single-tank) 735 55 0 0.86 0.205 Hot water (two-tank) 600 45 0 0.86 0.250

Combined system 3200 7050 0.89 0.89 0.265 Space heat system 2600 7000 0.89 0 0.268 Hot water (single-tank) 830 62 0 0.89 0.188 Hot water (two-tank) 700 53 0 0.89 0.22

Combined system 3600 7920 0.96 0.92 0.252 Space heat system 2900 8400 0.96 0 0.256 Hot water (two-tank) 800 60 0 0.92 0.20

29

Page 38: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I t.i~ TR-907 - 11.111 - ~~~

Table 3-1 .. COMPARISON OF SPACE-HEATING, HOT-WATER, AND COM-BINED SYSTEM PERFORMANCE (Concluded)

* * - Z Z ~ 0 0 E -Eo-< '""" - - U Eo-<

M U ~ E <: <: N - p:: - p:: ff:J. ~ ~

N ~ p:: - Eo-< p:: ~ 0 ff:J. <:

~ u Eo-< ~ ~

Eo-< Z ::;E U ~ :c: <: ~ ~ ~ <: ~ ~ -Eo-< ~ p:: u u

~ Eo-< -ff:J. 0 <: ~ ~ 0 Eo-< Q., 0 ~ ff:J. U ff:J. 00. :c: ~

Passive construction, two-tank system

Combined system 1600 2880 0.84 0.91 0.224 Space heat system 960 3000 0.84 0 0.228 Hot water (two-tank) 750 56 0 0.91 0.204

Combined system 1800 3600 0.94 0.94 0.217 Space heat system 1020 3600 0.94 0 0.224 Hot water (two-tank) 860 64 0 0.94 0.190

Superinsulated construction, two-tank system

Combined system 600 600 0.63 0.85 0.226 Space heat system 200 520 0.63 0 0.202 Hot water (two-tank) 360 24 0 0.85 0.257

Combined system 700 700 0.75 0.90 0.209 Space heat system 240 680 0.75 0 0.201 Hot water system 410 30 0 0.90 0.204

Combined system 800 960 0.90 0.926 0.199 Space heat system 320 900 0.90 0.182 Hot water (two-tank) 550 41 0 0.926 0.182

*Space heat fraction and hot water fraction refer to the percentage of the space heat and hot water loads, respectively, that are met by the solar heating system.

30

Page 39: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S;::~II~I _______________________________________________________ T~R~-~90~7L-

small and hot water accounts for a larger percentage of the total load. For superinsu­lated houses in which the hot water load is double the size of the space heating load or greater, the net added energy drops as much as 50% for a combined system when com­pared to a space heating system. This drop in the net energy occurs because the loss in efficiency of the hot water component is proportionately greater, while the amount of heat gained by the annual storage system becomes proportionately less. This effect is the same regardless of collector type. Because of this low net energy, tw<rtank systems are particularly useful for buildings with a larger load for hot water than for space heat.

Although a combined system offers no engineering advantage, it may offer a substantial economic advantage through the use of auxiliary equipment (piping, controls, etc.) that services both the space heat and hot water loads. Lovins (U.S. Congress 1978) has argued that the hot water component of a combined system may be used to justify the cost of auxiliary equipment that otherwise would make a space heat system prohibitively expen­sive for smail building loads.

3.6 SINGLE-UNIT SYSTEMS

Annual storage systems for an individual single-family residence (SUB 1) are of interest because a number of innovative systems of this type have been built in recent years. (Esbensen and Korsgaard 1977; Besant et ale 1978). The major problem with single-unit systems is storage loss: while a 50-unit annual storage system may have a storage effi­ciency of over 90%, a single-unit system such as the Lyngby house (Esbensen et ale 1977) may have a year-round storage efficiency of 60% or less.

Single-unit system si~ulations were performed, assuming the same level of storage-tank insulation (0.11 W/m °C) as assumed for 50-unit systems. Results show that the overall system efficiency for a single-unit system is 20%-30% lower than for the equivalent 50-unit system. The net added energy drops by 30%-50%. These results suggest that annual storage works much better for 50-unit districts than for individual houses. This is particularly true in light of economies of scale available in obtaining large storage tanks (Baylin et ale 1980b).

3.7 EFFECT OF COLLECTOR TILT

The two collector tilts used-tilt equal to latitude and tilt equal to latitude plus 10 degrees-result in slightly different performances. In general, the sharper tilt permits greater collection in winter at the expense of collection in the spring, summer, and fall. The sharp tilt is advantageous when storage is small. The shallower tilt increases summertime collection and thus makes use of larger annual storage tanks advantageous. When collector tilt is Shallower, the point of unconstrained operation will occur at a larger storage size.

Figure 3-12 illustrates the difference in performance brought about by the different col­lector tilts. The sharper tilt is definitely favored when storage is small, and the shal­lower tilt is favored when storage is very large. The crossover point is typically near the point of unconstrained operation. Because the crossover point occurs most often in Region C, the sharper tilt is more likely to be economically optimal. However, the shal­lower tilt permits greater performance for a collector of given size.

31

Page 40: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~II.I --------------------------~ ~

c: .2 () ctl ... u. ... ctl (5 en

1.0

0.95

0.80

0.65

0.50

0.35 Point of unconstrained operation, Tilt = Latitude + 10°

Point of unconstrained operation, Tilt = Latitude

0.20 '------..I.---__ ~ ______ ~ ____ ....1_ ____ ....J... __ _

2 3 4 5

Ratio of Storage to Collector Size (m3/m2)

Figure 3-12. System Performance with Varying Collector Tilt System i~ for Boston, Mass., SUB-50 standard load, space heat system with flat-plate collectors. Collector size is 2800 m2 •

32

Page 41: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

'" TR-907 S::~II~I-------------------------------------------------------------­-~ ~~

3.8 TWO-TANK SYSTEMS

A two-tank system improves system efficiency by permitting collection of low-temperature solar heat on a daily basis while the storage tank is fully charged. Figures 1-3 and 1-4 illustrate the operatioo and efficiency of the two-tank system, which, in effect, functions as a diurnal system during November through January with annually stored heat providing backup.

In the original concept as presented by Cha, Conner, and Mueller (1979), the daily storage tank in the two-tank system was used only to collect low-temperature solar heat during the late fall and early winter. When used in a combined space heat and hot water sys­tem, the daily storage tank may perform the additional function of collecting high­temperature heat for hot water when the annual storage tank is fully discharged. Figure 3-13 illustrates this type of operation. During the late winter months, the tem­perature of the annual storage tank drops to 300 -350 C. Because of its size, the annual storage tank does not heat up more than a few degrees on sunny days. As a result, only hot water preheat can be supplied during the late winter. During this period, the diurnal tank could be heated to 600 C on sunny days and used to provide hot water while the annual storage tank continued to provide space heat.

The algorithm used for this type of operation is as follows. As long as the annual tank temperature remains above 550 C, the diurnal tank is used to collect low-temperature heat. Heat for the load is taken first from the diurnal tank if available, driving down the temperature. Solar heat is collected for whichever storage tank is at the lowest temper­ature, thus providing the most efficient collection of solar heat. When the annual stor­age-tank temperature drops below 550 C, the mode of operation changes. Solar collection is used to heat the diurnal tank until its temperature reaches 600 C. When the diurnal tank temperature exceeds 600 C, solar collection is used to heat the annual storage tank. The diurnal tank is used preferentially to provide hot water. In this way, the two-tank system improves collectioo efficiency during November and December and also provides solar hot water in March and April.

Simulation results show that using the two-tank system in this way can result in a 3%-5% improvement in performance in comparison with a t,wo-tank system using the daily stor­age tank only to collect low-temperature heat. This improvement occurs only in systems with a large solar fraction (85% or over). The major effect of this "dual use ll of the two-tank system is to increase the amount of solar hot water provided. A single-tank system typically provides 80% of the hot water load, even when the system is sized to provide 100% of the space heat load. A two-tank system used only to collect low tem­perature heat (single use) would provide 85% of the hot water load along with 100% space heating, while with dual use the percentage of the hot water load supplied jumps to 90% or more. Interestingly, dual use also results in slight improvements in the percentage of the space heat load provided by the system. These improvements occur on the coldest days, when the heat exchange capacity within the building is too small to meet the build­ing load with low-temperature heat from the annual storage tank. On these days, the diurnal storage tank provides heat at a temperature high enough to meet the building load. When the solar fraction is less, dual use of the two-tank system neither provides a significant improvement in performance nor lowers system performance when compared to single use of the two-tank system.

33

Page 42: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I 'l'~ __ ~ ___________________ TR_-_9_07 ="" I_I

>­() c: Q)

() ;;::: -UJ

-() !!-Q) ... :::l -co ... Q) ~

E Q)

r-

0.5

0.4

0.3

0.2

0.1

80

70

60

50

40

30

20

A MJJASONDJF

Month

Annual Tank

" , \ I \

I , I , Diurnal \

\ Tank \

\ \ \ \ \ ,

\

A M J J A S 0 N o J

Month

____ Efficiency for "single use" two-tank system

Efficiency for dual use system

/

I

/

F M

Figure 3-13. Efficiency and End-ot-Month Storage Temperature tor a "Dual Use" Two-Tank System System is for flat-plate collector system; Boston, Mass., TUB-50, standard load.

34

Page 43: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S;::~I 1~1 ______________________________________________________ ~T~R~-~9~0~7

A comparison of the performance and trade-off graphs in Appendix C indicates that two-tank systems show more nearly linear characteristics than do single-tank systems in the intermediate storage region (Region B). This is probably caused by the variation in collector efficiency with increasing storage size. As explained previously in Sec. 1.0, single-tank systems show a drop in collector efficiency as the transition from diurnal to annual storage is made. No such drop in efficiency occurs with a two-tank system.

35

Page 44: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I~·;t\' - III III - ~

36

Page 45: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S;::~II~I--------------------------------------------------------------- ~~

SECTION 4.0

SYSTEM ECONOMICS

Results from the previous section indicate that near-lOO% annual storage systems may be economically preferable to the more common 50% solar heating systems with diurnal storage. In this section, system economics will be examined in greater detail. The anal­ysis will be based on three tests for cost-effectiveness: the collector/storage trade-off, the value added by storage, and the overall system evaluation. The trade-off and value­added tests are used to compare annual storage systems with solar heating systems lack­ing annual storage, while the overall evaluation compares solar and conventional heating systems. Only when all three indicators favor annual storage is such a system cost­effective.

System economics are difficult to assess because system costs vary greatly. This analy­sis will assume that system cost in 1979 dollars is the sum of the following three compo­nents (Baylin et ale 1980b, Drew and Selvage 1980, King and Carlock 1979):

• Collector cost at $140/m2 for flat-plate collectors or $200/m2 for evacuated­tube collectors,

• Auxiliary costs (piping, ductwork, etc) at $100/m2 collector area, and

• Storage cost as found from the equation (Drew and Selvage 1980)

Cost = 7.2 Vs + 530 Vs2/ 3 for volume Vs in m3.

This equation yields a cost of $30-$50/m 3 for the system sizes included here.

Each of these costs is subject to great variation. Estimates for collector and storage costs may range from one-half to twice the given values. Collector and auxiliary costs assumed here represent a minimum cost estimate based on a survey of solar heating installations (King and Carlock 1979). Storage costs may be much higher if poor soil con­ditions exist or much lower with innovative technologies (e.g., aquifers, solar storage ponds, ferrocement tanks). The assumed storage costs are based on surveys of the costs of concrete and steel storage tanks (Baylin et ale 1980b, Drew and Selvage, 1980).

The collector/storage trade-off, as explained in Sec. 3.1, determines whether annual storage is preferable to a system with increased collector size substituted for storage. Based on ihe3above costs, the break even point for annual storage will be a trade-off of 0.1-0.3 m /m. Annual storage systems are th~ref§X'e strongly favored in the three northern cities, where the trjdeaoffs are 0.4 m /m or larger. In Albuquerque, the trade-off rate is 0.15-0.25 m /m , indicating that a diurnal or weekly storage system with a larger collector area may sometimes be favored over an annual storage system.

The value added by storage is simply the dollar value of the additional energy supplied each year (for a fixed collector area) by adding annual storage to a solar heating sys­tem. If the value of the added energy is less than the incremental cost of the larger storage system, then annual storage is not economically justified. A diurnal solar heating system with a backup heating source substituted for annual storage would be preferred.

For the annual storage systews considered, the yearly energy vglue added by storage ranges from 130 to 210 MJ/m . The net added cost is $20-$30/m for large apartments and $35-$60/m3 for districts of single family houses, and includes the cost of the district heating system (Baylin et al., 1980b).

37

Page 46: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

,,"', TR-907 S=!'!tI U• 1I ------------------------------":..:=.-:;...:'-=­-~ ~~

The annual cost of a capitalized investment such as the storage system can be viewed as the annual payment that would amortize a loan over the life of the system. This "level­ized annual cost" can then readily be converted to the life-cycle cost of the energy pro­vided by the storage system by dividing the levelized annual cost by the energy supplied by the system. Because different purchasers will apply different discount rates for eval­uating the cost-effectiveness of systems, costs will b~ illustrated for several ~ifferent discount rates. Assuming that a system costs $30/m and provides 180 MJ/m with a useful life of 30 years, the cost of the energy supplied is

• 6.4tVkWh for a 1096 discount rate,

• 5.3A'kWh for an 8% discount rate, and

• 3.5A'kWh for a 496 discount rate.

These costs may alternatively be viewed as break-even costs for the storage system with a 1096 discount rate and 096, 2%, and 696 real escalation in the annual cost of conven­tional fuels; i.e., if a life-cycle cost analysis is performed for a 1096 discount rate and the real cost of electricity is assumed to increase by 296 annually, the annual storage sys­tem considered would be preferable wherever the cost of backup heat now exceeds 5.3A'kWh.

Overall system economics are evaluated similarly by calculating life-cycle/break-even energy costs. Table 4-1 presents costs for combined space heating and hot water systems based on the above solar system cost estimates and performance results for the systems and locations considered in this study. Results indicate that annual storage systems may be cost-effective in large parts of the United States if high fuel escalation rates are assumed. Incorporating the solar tax credits would lead to similar conclusions for lower fuel escalation rates.

Due to economies of scale in storage, annual storage systems are most advantageous for large apartment complexes or districts. Note that the cost of energy from the storage component is often equal to or slightly less than the cost of energy from the entire sys­tem. Consequently, the cost of energy from the system will remain essentially constant as the solar fraction is increased to 100%, as shown in Fig. 3-9. Whenever the storage energy cost is less than or equal to the system energy cost, near-lOO% annual storage systems will be preferable to smaller diurnal systems.

38

Page 47: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~II.I __________________________ --=T:..::R.:..---..:.9-..:.0_7 - ~~~

Table 4-1. L1FE-CYCLE/BREAK-EVEN ENERGY COST OF ANNUAL STORAGE SYSTEMS

(Life-cycle/break-even costs in 1979 tVkWh are calculated for flat-plate, two­tank systems for a 50 single-family house district that provides heat and hot water. Break-even costs assumed are a 10% discount rate, 30-year amortiza­tion period, and either 2% or 6% fuel escalation per year. This corresponds to life-cycle energy costs with 8% and 4% discount rates respectively. Solar energy system costs are found from the equation:

Cost = 240 Ac + (7.2 V s + 530 V s 2/3),

f or a collector size Ac in m 2 and storage size V s in m 3.)

Fuel Break-even Cost in 1979 tVkWh Escalation

Construction Rate Boston Medford Bismarck Albuquerque

Standard 2% 7.5 5.7 6.8 4.1 6% 4.8 3.7 4.4 2.7

Passive 2% 9.1 7.6 9.1 4.9 6% 5.8 4.9 5.8 3.1

Superinsulated 2% 9.8 8.1 10.2 4.9 6% 6.3 5.2 6.6 3.1

39

Page 48: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~IW - III_"I - ~

40

Page 49: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 5;::~1 I~I-------------------------------------------------------------­-~ ~~~

SECTION 5.0

D~IGN METHODS

Design tools for annual storage systems were the subject of a recent study by the authors (Baylin and Sillman 1980). A model of annual storage systems using a utilization formula for collector efficiency and bimonthly steps was found to yield accurate results for standard building loads and was recommended for system design. The question is whether a bimonthly simulation remains accurate when used with passive, superinsulated, or other conserving building loads. An examination of this question is presented below.

For single-tank annual storage systems, the nature of the building load has no effect on design tool accuracy. The bimonthly utilization model is found to perform accurately with all bulding load types, so long as the accurate monthly building load data are pro­vided. A possible problem arises only when the storage tank size is small, so that month­to-month variation in storage tank temperature may exceed 20° C. This will not happen for annual storage systems at the point of unconstrained operation, even if the hot water load is large. For two-tank systems, however, some inaccuracy may result from using a bimonthly model for system design with an energy-conserving building.

A simple method for sizing systems near the point of unconstrained operation has been developed by Drew and Selvage (1980). A summary of their method is presented below:

(1) The desired maximum and minimum storage temperature is selected for the yearly cycle.

(2) Storage temperature for each month is calculated assuming that storage tem­perature follows a sinusoidal pattern over the year with maximum occurring on 1 October and minimum on 1 April (the exact time of yearly minimum and max­imum can be adjusted).

(3) Collector efficiency for each month is calculated by the utilization method (Klein 1978), based on the above monthly storage temperatures. Solar heat col­lection for each month is also calculated.

(4) The amount of heat supplied to the load from storage is calculated for each month based also on the assumed monthly storage temperature.

(5) Collector and storage sizes for the above system are found by solving two simultaneous equations, one for system performance from 1 April to 30 Septem­ber and one for performance from 1 October to 31 March. During the summer half, collected solar energy must equal the sum of (1) load for the period, (2) storage losses, and (3) the amount of energy needed to raise storage from its minimum yearly temperature to its maximum. During the winter, the heat sup­ply is equal to collected solar energy plus the amount of heat liberated when storage temperature drops from its maximum to its minimum value. This heat supply must be equal to solar load plus storage losses. This analysis results in two equations with only collector and storage sizes unknown. Collector and storage size for the system may thus be found.

41

Page 50: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

42

Page 51: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S;::~I 1~1 ________________________________________________________ ~T~R~-~9~O~7_

SECTION 6.0

CONCLUSIONS

The study presented should provide a comprehensive look at the design trade-off and per­formance of annual-cycle solar heating systems. The following are general conclusions.

• The performance curves for active solar heating systems with storage show three distinct regions: a region of diurnal storage, an intermediate region, and a region of annual storage. System performance is found to increase linearly as storage size increases throughout the intermediate region. The likely economic optimum occurs at the point of "unconstrained operation," at which the storage tank is large enough to store all heat collected in summer.

• In contrast to diurnal storage systems, annual storage systems show only slightly diminishing returns as the solar heat fraction increases. Optimal annual storage systems are sized to meet nearly 100% of the building space heat loads. These near-lOO% systems may be preferable to the more common 50%-solar systems in many cases.

• Also in contrast to diurnal systems, annual storage systems perform efficiently when combined with passive solar or other energy-efficient building designs.

• The size of storage necessary for an annual storage system at the point of uncon­strained operation varies great~. S~ace-heating systems typically have a stor­age-to-collector ratio of 3-5 m :1 m . Combined space- and water-heating sys­tems have proportionately less storage, especially when the space-heating load is sma¥. :w some cases, a system may have a storage-to-collector ratio of 1 m :1 m or less and still function as an unconstrained annual storage system.

• Inclusion of annual storage in ~ active solar heating system results in a net added

2energy of 130-210 MJ/m per Y3ear. Based on a net added energy of 180

MJ/m each year and a cost of $30/m , the break-even cost of energy added by annual storage is 4~6NkWh. The total system breaks even against an energy source that costs 4~9NkWh.

43

Page 52: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

------

S=~I

44

Page 53: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S::~II~I ________________________________________________________ T_R_-_9_0 __ 7 -~ ~~

SECTION 7.0

REFERENCES

Baylin, F.; Sillman, S. 1980 (July). Systems Analysis Techniques for Annual Cycle Thermal Energy Storage Systems. SERI/RR-72 1-676. Golden, CO: Solar Energy Research Institute.

Baylin, F.; Monte, R.; Sillman, S. 1980a. 1980 (June). Annual-Cycle Thermal Energy Storage for a Community Solar System-Details of a Sensitivity Analysis. SERI/TR 355-575. Golden, CO: Solar Energy Research Institute.

Baylin, F.; Monte, R.; Sillman, S.; Hooper, F. C.; McClenahan, J.D. 1980b. Economic Analysis of Community Solar Heating Systems That Use Annual Cycle Thermal Energy Storage. Golden, CO: Solar Energy Research Institute.

Besant, R. W.; Dumont, R. S.; Schoenau, G. 1978. The SaSkatchewan Conservation House: Some Preliminary Performance Results. Saskatoon, Canada: University of Saskatchewan.

Braun, J. E.; Duffie, J. A. 1979. Design of Space Heating Systems Employing Seasonal Sensible Storage. Madison, WI: Solar Energy Laboratory, University of Wisconsin.

Cha, B. K.; Conner, D. W.; Mueller, R. O. 1979. "A "Two-Tank" Seasonal Storage Con­ceptfor Solar Space Heating of Buildings." Proceedings of Second Miami International Conference on Alternative Energy Sources. Miami, FL; 10-13 Dec. 1979.

Drew, M. S.; Selvage, R. B. G. 1980. "Sizing Procedure and Economic Optimization Methodology for Seasonal Storage Solar Systems." Solar Energy. Vol. 25 (No.1): pp. 79-83.

Esbensen, Torben, V.; Korsgaard, Vagn. 1977. "Dimensioning of the Solar Heating Sys­tem in the Aero Energy House in Denmark." Solar Energy. Vol. 19 (No.2): pp. 195-199.

Hooper, F. C.; Cook, J. D. 1980. "Design of Annual Storage Space Heating Systems." Fundamentals and Applications of Solar Energy. AIChE Symposium Series 198. Vol. 76: pp. 80-91.

King, T. A.; Carlock, J. B. 1979. Construction Cost Factors Identified in Commercial Solar Energy Systems. SOLAR/0822-79/60. Baltimore, MD: Mueller Associates.

Klein, S.A. 1978. "Calculation of Flat-Plate Collector Utilizability." Solar Energy. Vol. 21 (No.5): pp. 393-402.

Klein, S.; Duffie, W.; Beckman, R. 1977. Solar Heating Design. Wiley and Sons.

McGarity, A. E. 1979. "Optimum Collector-Storage Combinations Involving Annual Cycle Storage." Proceedings of Solar Energy Storage Options. San Antonio, TX: 19-20 Mar. 1979; pp. 165-173.

Mixon, W. R. 1976. 1976 (Dec.). "Technology Assessment of Modular Integrated Utility Systems." ORNL/HUD/MIUS-25. Oak Ridge, TN: Oak Ridge National Laboratory; pp. 3-134.

45

Page 54: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S;::~I I~I--------------------------------------------------------------- ~~

Palmiter, ttSUNCAT Version 2.4 User Notes."

Shurcliffe, W. A. 1980 (Mar.). Super insulated Houses and Double Envelope Houses. 19 Appleton St., Cambrfdge-;-lVIA.:'N. A. SnurcliIfe.

Swet, C. J.; Baylin, F. 1980. Central Unresolved Issues in Thermal Energy Storage for Building Heating and Cooling. SERI/RR-72 1-455. Golden, CO: Solar Energy Research Institute.

U.S. Congress. House. 1980. Hearings before a Subcommittee on Government Opera­tions. Washington, DC: United States House of Representatives; Sept. 1978.

46

Page 55: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

'" TR-907 S::~II~I-------------------------------------------------------------­-~ ~'1!~

APPENDIX A

BASIC ASSUMPTIONS IN THE SOLAR HEATING SYSTEM

A. COLLECTOR PERFORMANCE

Flat-plate collector Evacuated-tube collector

Fr (ad

0.661 0.397

FrUl [W/m2]

6.104 1.170

*The terms Fr (a·r) and FrU l are terms from the instantaneous solar collection equation:

Qc = Fr (aT) I - FrUl~T

where Qc is collected solar heat, I is incident solar radiation, and ~T is the difference between the collector, and ambient temperatures. Collector temperature is assumed equal to the average storage temperature.

B. STORAGE

Storage losses are calculated based on a constant storage U-value of 0.11 W/m20·C. Storage losses are calculated relative to ground temperature, which is assumed equal to average year-round ambient temperature.

Maximum Storage Temperature: 79.5° C.

C. TRANSMISSION LOSSES

Transmission losses from collector to storage and from storage to load are ignored. They are assumed to be accounted for by storage losses.

D. HEAT EXCHANGE CAPACITY

Ability of the heating system to meet the load depends on (a) size of the load, (b) size of heat exchange between heat source and load, and (c) temperature difference between heat source and room temperature. Assuming that building load is proportional to the difference between ambient and room temperature, the fraction of the building load that may be supplied by a solar heating system is:

Ts- Tr Solar fraction = Xh T _ T

r a

where Tr is room temperature (assumed to be 20°C in this study), Ts is the temperature of the lieat source, T a is ambient temperature, and Xh is a di~ensionless coefficient (Klein et ale 1977). In this study the coefficient Xh has the followmg values:

47

Page 56: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S;::~I !~I---------------------------------------------------------------~ »~

For single-tank systems, Xh = 2,

Xh

= r-for-tneaiurnaCtanK, and-----~-~---------~ - ----

Xh = 1 for the annual tank.

E. HOT WATER PREHEAT

The fraction of the hot water load that may be met by the solar heating system is simi­larly dependent on a heat-exchange effectiveness formula. In this simulation the formula is

Ts - 10 Hot water fraction = 52 _ 10

where T s is heat-source temperature. This assumes a cold-water temperature of 10° C, a hot-water temperature of 49°C, and a heat-exchange effectiveness of 92%.

48

Page 57: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~I 1\.1 ----------------------------~ ~

APPENDIX B

CALCULATION OF PASSIVE AND CONSERVING BUILDING LOADS

Passive and conserving loads were included in this study in order to investigate what effects the load may have on the performance of active solar heating systems. Conse­quently, the passive-load algorithm need not find the precise load of a particular build­ing. The purpose of the load algorithm is to generate a load pattern that reflects. the daily and monthly load variation of a passive or superinsulated building design, rather than an exact load.

The load algorithm requires four input parameters:

• Building gross shell loss coefficient, in watts per degree Centigrade;

• Effective passive collection area, in square meters (the effective area is assumed modified to reflect window angles, transmission losses, and other losses);

• Miscellaneous heat gain, in watts, due to inhabitants and electric appliances; and

• Effective thermal-mass capacity in watt-hours. This term gives the quantity of heat which may be stored without bringing discomfort to the residents.

The algorithm calculates the heat load for each day in two periods, one for daytime and one for nighttime. For each period the following five steps are performed.

(1) Building gross shell loss for the period is calculated based on the difference between room temperature (assumed to be a constant 200 C) and ambient tem­perature and the shell-loss coefficient. This step parallels the degree-day method of calculating building loads.

(2) Miscellaneous heat gain for the period is calculated and the gain is subtracted from the gross shell load. If the miscellaneous heat gain exceeds the load, excess heat is stored in thermal mass.

(3) Passive gain in daytime is calculated from the total daily radiation and the effective passive collection area. The passive gain is subtracted from the build­ing load remaining at the end of Step 2. Again, if excess heat remains, it is added to passive storage.

(4) If necessary, heat is removed from thermal mass to meet whatever positive net building load remains at the end of Step 3. If stored heat is insufficient to meet the building load at this step, the remainder becomes the net building load for the period and will be met by either active solar or auxiliary heat.

(5) The amount of heat stored in thermal mass is carried over to the next period. The amount of passively stored heat is not allowed to exceed the effective thermal mass capacity.

When the parameters are set properly, this algorithm generates a load pattern that meets the criteria for use in this study. The load size may be set appropriately; and the load changes from day to day, reflecting the amount of insolation. For passive construction, the effective passive collection area is sized to meet nearly all the load on a sunny win­ter day. Thermal-mass capacity is set to accommodate nearly all the load of a mild win­ter night. Thus, on a sunny, mild winter day there would be virtually no load, while on a

49

Page 58: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S;::~I i~I--------------------------------------------------------------- ~~

sunny-and-cold or cloudy-and-mild winter day there would be a moderate load. Param­eters for a superinsulated house are set in the same way, although both passive collection

__________ area and thermal-mass cagac!!y are much reduced because the gros~hell loss is reduced. These sizings result in a building that obtains 50% of its spaceheatirig -requirements from passive gain in a northern location. As described in Sec. 2.6, param­eters for large apartment buildings wer-e set differently to reflect limitations on the use of passive solar construction with such apartment buildings.

Table B-1 shows a comparison between results of the passive load algorithm and data generated by the SUNCAT 2.4 hourly passive simulation (Palmiter). As shown in Table B-1, the passive algorithm cannot be used accurately to predict actual building loads. The monthly and daily loads, however, are all reasonably close to the SUNCAT data. Simulation results with the passive load algorithm should therefore reflect accu­rately the performance of active solar heating when coupled with a passive building load pattern. The monthly and daily load patterns for superinsulated buildings are designed to approximate the load pattern of the Saskatchewan Conservation House (Besant 1978) and the Lyngby House (Esbensen and Korsgaard 1977).

Tables B-2 and B-3 give the values of the parameters and building performance for each of the types of buildings and each location used in this study. SUB 50, TUB 50, and HUB 200 refer to the building types, explained in Sec. 2.0.

50

Page 59: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~II.I ------------------------------~ <§~~

Table B-1. COMPARISON BETWEEN PASSIVE LOAD ALGORITHM AND SUNCAT SIMULATION

Month

Apr.

May

June

July

Aug.

Sept.

Oct.

Nov.

Dec.

Jan.

Feb.

Mar.

Data below compare monthly and daily loads in GJ generated by the passive load algorithm with loads generated by the SUNCAT hourly simulation. Simula­tion is for Madison, Wis., using TMY meteorological data. The passive load algorithm used the following param eters:

Gross shell loss coeff. 48 MJ/hoC Miscellaneous heat gain 80 MJ /h Passive gain effective area 700 m2

Effective thermal mass capacity 10 GJ.

Monthly Loads Daily Loads

Passive SUNCAT Day Passive Algorithm Algorithm

104 1.8 Jan. 1 0.38

0.6 0.7 Jan. 2 0.22

0 0 Jan. 3 0.24

0 0 Jan. 4 0.37

0 0 Jan. 5 0.28

0 0 Jan. 6 0.34

1.0 1.5 Jan. 7 0.26

6.6 6.0 Jan. 8 0.42

11.4 10.8 Jan. 9 0.54

13.6 12.2 Jan. 10 0048

9.4 9.4

6.5 6.0

51

SUNCAT

0.40

0.21

0.15

0.30

0.23

0.30

0.25

0.48

0.42

0.36

Page 60: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I r.I~ TR-907

- 1111111 - ~~

Table B-2. BUILDING PARAMETERS

---------.------------------------- ---~-~-. U

0 I-;) -J: C"l ~o - E rnl-;) ~

'-' ~-0 0 z < ~~ t-:l- - ~ < ~E-< t-:l E-<~ 0 z~ :I:-t-:lZ -< E-<U

~ E-< <~ ~< 0... ~~ < :I:- 0:> :>0... ~ rnU ~ ~r;:: r;::< E-< - :I:J: 0

rnr;.; .- ~U UU rnr;.; UI-;) rn~ ~gs < o~ ~

rnr;.; r;.;< 0 ~o <r;.; t-:l OU :;E~ o...~ ~:;E

BOSTON, MASS.

SUB 50

Standard 53 80 0 0 Passive 40 80 700 10 Superinsulated 15 70 250 4

TUB 50

Standard 22 40 0 0 Passive 16 40 220 4 Super insulated 7 32 100 2

HUB 200

Standard 56 120 0 0 Conserving 25 100 250 5

BISMARCK, N. DAK.

SUB 50

Standard 52 80 0 0 Passive 40 80 800 12 Super insulated 13 70 250 4

TUB 50

Standard 22 40 0 0 Passive 16 40 300 5 Super insulated 6 32 120 2

HUB 200

Standard 54 120 0 0 Conserving 22 100 300 5

52

Page 61: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~. TR-907 = (~~I

Table B-2. Bun.DING PARAMETERS (Concluded)

U 0 I-;) -,.c C'I ~o - E 00.1-;) - ~-rh.O Z 0 0 ~ ~l>-t ......

~ ...:l- ~ ~E-< ...:lE-< 0 Z~ ::q ...... ...:lZ ...... ~ E-<U

~ E-< ~~ ~~ ~~ ~ p.. ::q ...... 0> >p.. l>-t mU ~ ~ ...... E=:~ E-< ...... t:t::,.c >E-< m~ UU 0 m~ .- ...... U

~m UI-;) m~ ~ o~

~ m~ ~m 0 ~o

~~ ~~ ~~ ...:l OU p..~ ~~

MEDFORD, OREG.

SUB 50*

Standard 53 80 0 0 Passive 40 80 700 10 Superinsulated 15 70 250 4

TUB 50*

Standard 22 40 0 0 Passive 16 40 220 4 Super insulated 7 32 100 1

HUB 200*

Standard 56 120 0 0 Conserving 25 100 250 5

ALBUQUERQUE,N.MEX.

SUB 50

Standard 53 80 0 0 Semipassive 35 70 300 5 Passive 40 80 600 10

TUB 50

Standard 22 40 0 0 Passive 16 40 200 4

HUB 200

Standard 56 120 0 0 Conserving 30 100 200 4

53

Page 62: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I 'l~ TR-907

- iflll"l -- ~~~

Table B-3. BUILDING LOADS

--------

..-.. ~ CI CI.l 0 <

~ --- 0 ~ CI.l CI CI ~ Eo< CI.l ~ ~Z Eo< < 0 ...... ............ < :s: ~ ~Eo< ~< ~ ~< ~o ~

Eo< ::t: ~ ~ ~~

~~ O~ ~ fi5::t: ~

~ ::t: ~ CI.l> U ~

>-t ~. ~- -< ~ ~o Eo< CI.l:;... CI.l U CI.lCl.l ~<' <-CI.l- o~ o~ CI CI.l~ CI.l~ ~CI < Q:--l ..... ~ ..... ~ Eo<C"I Z< 0 ~o 0>-t 0>-t ~ ...... Zo ~ 0- ~o:l ~o:l Z~ <~

BOSTON, MASS.

SUB 50

Standard 4.441 0.125 0.000 3.890 0.876 Passive 3.352 0.166 0.472 1.216 0.840 Superinsulated 1.257 0.356 0.388 0.322 0.548

TUB 50

Standard 1.844 0.149 0.000 1.570 0.876 Passive 1.307 0.209 0.397 0.516 0.840 Superinsulated 0.587 0.350 0.354 0.175 0.511

HUB 200

Standard 4.693 0.173 0.000 3.880 1.752 Conserving 2.095 0.312 0.280 0.855 1.460

BISMARCK, N. DAK.

SUB 50

Standard 6.602 0.091 0.000 6.000 0.975 Passive 5.079 0.119 0.478 2.047 0.975 Superinsulated 1.651 0.297 0.396 0.506 0.657

TUB 50

Standard 2.793 0.107 0.000 2.495 0.975 Passive 1.981 0.151 0.457 0.776 0.975 Super insulated 0.762 0.295 0.410 0.225 0.657

HUB 200

Standard 6.856 0.129 0.000 5.975 1.945 Conserving 2.793 0.256 0.320 1.186 1.643

54

Page 63: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~~ TR-907

- iII.11i - ~~~

Table B-3. BUILDING LOADS (Concluded)

........ ...:l 0 ct:l < 0 ~ - 0 ct:l 0 0 ...:l ~

E-< ct:l ~ ~Z E-< < 0 ..... :::1 ..... < ...:l ...:lE-< ~< ~ ~ ...:l ~< ~O ::r:: E-< ...:l ~~

P~ o~ ~ ~ ~::r:: ~ ~ ~ ::r:: s:..

ct:l:> Us:.. ~ ...:l • ...:l ..... ......

ct:l:>, ct:l U ct:lgs <» ...:lo E-< ~- < ...... 0 gs;:;- of!3 0< ct:l~ PO < 0c"I ..... :?1 ..... ~

~ Z< 0 ~o o~ o~ Zo ...:l 0 ...... ~~ ~~ Z~ <...:l

MEDFORD, OREG.

SUB 50

Standard 4.101 0.154 0.000 3.471 0.803 Passive 3.095 0.207 0.497 0.918 0.803 Superinsulated 1.161 0.433 0.369 0.231 0.511

TUB 50

Standard 1.702 0.183 0.000 1.391 0.803 Passive 1.207 0.261 0.423 0.384 0.803 Superins ulated 0.542 0.426 0.347 0.124 0.511

HUB 200

Standard 4.333 0.212 0.000 3.415 1.606 Conserving 1.934 0.382 0.299 0.620 1.460

ALBUQUERQUE, N. MEX.

SUB 50

Standard 3.559 1.145 0.000 3.044 0.840 Semipassive 2.351 0.191 0.502 0.724 0.730 Passive 2.686 0.191 0.703 0.291 0.840

TUB 50

Standard 1.477 0.171 0.000 1.224 0.840 Passive 0.237 0.636 0.136 0.840 0.840

HUB 200

Standard 3.761 0.198 0.000 3.016 1.679 Conserving 2.015 0.299 0.386 0.636 1.314

55

Page 64: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

----- -------

56

Page 65: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S::~I !~,--------------------------------------------­-~ ~~

APPENDIX C

SIMULATION RESULTS

The following tables offer a summary of the numerical results of this study. Included are representative system sizes for each type of system investigated, and system descrip­tions in terms of the parameters discussed in Sec. 3.0.

The tables present collector and storage sizes foc annual storage systems designed to meet 95% of the system space heat load. Both the fraction of hot water provided and the total solar fraction vary among the systems presented. This criterion was selected for system sizing in order to avoid misleading results that can occur when a predomi­nantly hot water system is compared with a predominantly space heating system with the same solar fraction. As discussed in Secs. 3.2 and 3.5, optimal annual storage systems typically provide 95%-100% of the building space heat load but only 80%-90% of the hot water load. Proper system sizing is therefore based on the system's projected ability to meet the space-heating load rather than the total load. All system sizes presented are for points of unconstrained annual storage operation, as defined in Sec. 3.0.

In the two-tank systems, the second storage tank is always sized according to the collec­tor area (Ac)' using the formula

vs <m 3) = 0.075 Ac<m 2) •

In addition to collector size, storage size, and total solar fraction, the tables give the following parameters:

• Overall system efficiency for the. annual storage system. This is defined as the total heat delivered to the load, divided by the total energy incident on the col­lector for the year.

• Diurnal solar fraction. This is the solar fraction foc a diurnal system with the same collector area as the given annual system. Storage size in cubic meters is one-fifth the collector size in square meters foc the diurnal system. If the annual storage system is a two-tank system, the diurnal solar fraction is also based on a two-tank system, with the sam~sized second tank as in the annual system.

• Net added energy. This is based on a comparison 'of the performance of the annual storage system and the diurnal system described above. Net energy is calculated by the following formula:

heat delivered by annual system - heat delivered by diurnal system Net energy = ---------------------------

annual storage volume - diurnal storage volume

The annual and diurnal systems, as sized here, represent the boundaries of the intermediate storage region in the system-performance graphs (Region B) as described in Sec. 3.0. As explained in the text, the net energy added by storage gives the slope of the system-performance curve, which is usually a linear curve in this regi on.

57

Page 66: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 !s::~1 !~I--------------------------------------------------------------- ~~~

• Collector storage trade-off rate. This parameter gives the rate at which collec­tor area may be replaced by storage volume in systems with the same total solar

--------- - ----fraction -as-the-annual--stera-ge-system-. -As-wit-h-the- value-ei'-sterage,the-trade---------­off is close to linear. Systems are for both space heat and hot water, with tilt equal to latitude plus 10 degrees, unless mentioned otherwise.

Also presented are the system-performance and collector/storage trade-off graphs for the locations, collector types, and building designs included in this study. System plots are all for SUB-50 systems. Both space heat and combined systems are presented.

The system performance curves represent a number of different collector sizes. Collec­tor sizes for each plot are listed below the graph. The y-axis gives solar fraction ranging from 0.2 t031.0~ The x-axis gives the ratio of storage size to collector size, ranging from zero to 5 m /m collector area.

The trade-off graphs present isoquant curves for solar fractions of 0.75, 0.80, 0.85,0.90, 0.95, and 0.99. For combined systems, the last isoquants (with s()lar fractions of 0.95 and 0.99) may be omitted. This omission occurs because a combined system may need to sup­ply not just 100% solar space heat but also an inordinately large percentage of the hot water load in order to meet a high combined solar fraction. Such systems would have to be oversized. A typical combined load system may meet 100% of the space heat load and 85% of the hot water load, for a combined solar fraction of 92%. In such a case, iso­quants for higher solar fractions would be omitted.

In the trade-off graphs, storage volume is plotted on the y-axis and collector area on the x-axis. The scale of the x- and y-axes are in the same proportion to each other for all trade-off graphs, with one square meter collector area corresponding in scale to one cubic meter storage. Also plotted on the trade-off graphs are discrete points represent­ing the region of unconstrained operation.

58

Page 67: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~~ TR-907 - 11111111 - ~~

SIMULATION RESULTS BOSTON, MASS.

Flat-Plate Collector - Single-Tank System

OJ

>; b.O a:!

<: p;::j 0 1\0< 0 ~ 21 Z Z ~ +-'

0 0 p;::j Ul ~ 0 - - Z M <: ...:l Eo-< Eo-< S 0 0 0 ~ ~ >; ~-;:; p;::j 0- >- 0 <: <: 0

~o ~ ~S ~ ...:l~ ~

>; Eo-<C"I Z 0 O~ Eo-< o S ~- ~ ~ <:~ 0 I OJ

~- - ~ Z~ ~::::I 0 ...:l ~ 0 <: ~<:

<:M 00 <: ...:l - Eo-<~ <:t> 0 ~ ...:l O...:l 0 0 Eo-< .~ 0 -0 ~~ ~S ...:l 0 r:n ~ r:n Or:n Z~

SUB 50

Standard 3830 8880 0.230 0.925 0.717 124 0.47 Passive 1800 3960 0.207 0.905 0.677 129 0.63 Super insulated 850 ll80 0.183 0.889 0.788 87 0.47

SUB 50 - space heat only

Standard 3120 8740 0.237 0.950 0.660 140 0.55 Passive llOO 3800 0.210 0.950 0.482 160 0.83 Superinsulated 350 1000 0.174 0.950 0.486 160 1.10

SUB 1

Standard 97 172 0.182 0.929 0.792 90 0.47 Passive 54 68 0.138 0.905 0.795 80 0.50 Superinsulated 24 20 0.131 0.901 0.857 51 0.40

TUB 50

Standard 2000 3600 0.220 0.903 0.768 llO 0.43 Passive 1250 1700 0.192 0.885 0.794 85 0.40 Super insulated 700 560 0.174 0.890 0.852 64 0.35

HUB 200

Standard 4500 9100 0.227 0.909 0.744 ll5 0.45 Conserving 2100 2550 0.200 0.885 0.800 100 0.42

*System with collector tilt equal to latitude.

59

Page 68: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~~ - HlII"1 - ~~

TR-907

SIMULATION RESULTS BOSTON, MASS.

Evacuatefr..-'fube-conector--=Singl~'l'ank-System-----~~--~ ----------

Q)

~ b.O Q:l

< 0 ~ ~ 0

~ ~ Z Z ~ +J

~ 0 0 ~ rIl

< 0 E:: - Z M ...:l E-o ~ S

~ 0 ~ 0 0 ~"i::' ~ 0- >- 0 < < 0 ~ 0 ~

~S ~S ~ ...:l~ ~ ~ Z 0 ot E-o ~- ~- ~

~ <~ 0 r:.G Q) - ~ Z~ 0 ...:l 0 <M O~ ~ < ~< E-o~ < ...:l 0 Ei:: ...:l O...:l < eJ 0 0 E-o ~ 0 -0 ~~ ~S ...:l 0 en ~ en Oen Z::E

SUB 50

Standard 3000* 9200 0.284 0.921 0.610 172 0.47 Passive 1350 3750 0.271 0.897 0.608 172 0.55 Superins ulated 590 1180 0.258 0.877 0.713 135 0.42

SUB 50 - space heat only

Standard 2600* 8400 0.278 0.950 0.578 180 0.45 Passive 850 3200 0.272 0.950 0.406 210 0.77 Superinsulated 260 1000 0.236 0.950 0.404 170 0.77

SUB 1

Standard 73* 200 0.226 0.932 0.675 125 0.38 Passive 36 80 0.204 0.892 0.694 115 0.33 Superinsulated 16 25 0.191 0.878 0.791 90 0.25

TUB 50

Standard 1500* 4000 0.282 0.895 0.665 160 0.60 Passive 900 2050 0.256 0.875 0.717 120 0.33 Superinsulated 460 750 0.259 0.858 0.771 90 0.25

HUB 200

Standard 3500* 9300 0.284 0.904 0.650 165 0.40 Conserving 1460 3000 0.269 0.872 0.708 140 0.40

*System with collector tilt equal to latitude.

60

Page 69: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~ = !.I TR-907

SIMULATION RFl)ULTS BOSTON, MASS.

Flat-Plate Collector - Two-Tank System

Q)

>- bD ctI

<: ~ 0 '" Z Z ~ 0

~ ~ ...

0 0 ~ CIl ~ 0 - e:: z M <: ~ E-o ~ E ~ 0 >- 0 0

0 ~"'l::;-~ >- <: <: ~ 0- 0 ~ ~~ ~ ~.B >- E-oC'l ~E Z 0 OC) E-o OE 0_ ~

~ <:~ 0 I Q)

~- <: - ~ Z~ <:M ~:::I 0 ~ ~ 0 <: ~<: E-o~

00 <: ~ - <:C) 0 ~ ~ O~ 0 0

~ ~ 0 sSl ~~ ~E ~ 0 ~ rI.l Z~

SUB 50

Standard 3550 7840 0.254 0.944 0.691 170 0.55 Passive 1800 3700 0.215 0.944 0.691 155 0.67 Superinsulated 850 1180 0.195 0.946 0.802 145 0.83

SUB 50 - space heat only

Standard 2800 8000 0.263 0.950 0.620 175 0.53 Passive 1100 3600 0.212 0.950 0.500 170 0.63 Superinsulated 350 1000 0.179 0.950 0.520 155 0.77

SUB 1

Standard 90 155 0.202 0.944 0.764 130 0.55 Passive 50 65 0.156 0.946 0.791 100 0.60 Superinsulated 23 25 0.141 0.944 0.877 52 0.35

TUB 50

Standard 1900 3300 0.238 0.938 0.751 155 0.53 Passive 1200 1700 0.215 0.941 0.791 145 0.60 Superinsulated 680 600 0.191 0.944 0.863 120 0.60

HUB 200

Standard 4250 8600 0.248 0.939 0.725 165 0.50 Conserving 2000 2700 0.216 0.935 0.790 145 0.55

*System with collector tnt equal to latitude.

61

Page 70: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I1;,ii = I_I TR-907

SIMULATION RESULTS BOSTON, MASS.

----------------- -----Evaeuat~'I'ube-GQnector-=---Tw~T_ank-System----- --------------

CI)

>t bD ctS

0 c... < ~ Z Z ~

0 ~ ::E

... 0 0 ~ til

~ ::> e:: .... z ~ < ...:I E-< ~ E ~ 0 >t

C,) C,) Q ~'C::;

~ 0- >- C,) < < ~ ~ 0 ~

~E ~E Z ~ ...:I~ Q O~ >t ~ <~ Eo-< ~- ~- ~ ~

Q ~ CI) .... Z~ <M Q~ Q ...:I ~ C,) < ~< Eo-<.e. < ...:I .... < () 0 ~ ...:I ::>...:1

0 0 ~

~ 0 .... 0 ~"":l ~E ...:I C,) ~ CI.l QCI.l Z2:

SUB 50

Standard 2800* 8100 0.310 0.941 0.612 210 0.47 Passive 1360 3800 0.283 0.942 0.631 185 0.45 Superinsulated 590 1180 0.271 0.936 0.734 165 0.47

SUB 50 - space heat only

Standard 2250* 8200 0.325 0.950 0.542 200 0.45 Passive 820 3700 0.282 0.950 0.420 185 0.40 Superinsulated 250 1000 0.246 0.950 0.426 180 0.63

SUB 1

Standard 70 160 0.256 0.944 0.685 170 0.45 Passive 35 77 0.222 0.945 0.708 140 0.45 Superinsulated 16 23 0.204 0.941 0.818 110 0.50

TUB 50

Standard 1460 3400 0.307 0.935 0.670 210 0.45 Passive 900 1700 0.282 0.938 0.735 180 0.45 Superinsulated 460 720 0.280 0.930 0.788 160 0.39

HUB 200

Standard 3350 8200 0.316 0.938 0.651 220 0.50 Conserving 1450 2900 0.292 0.931 0.723 195 0.47

*System with collector tilt equal to latitude.

62

Page 71: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~~ TR-907 - 11111111 - ~~~

SIMULATION RESULTS MEDFORD, OREG.

Flat-Plate Collector - Single-Tank System

aJ btl

:>! as 0 ~ < ~ Z

0 ~ :E Z ~ ~

0 0 ~ 00

~ ::;, E=

.... Z M < ...:I E- E 0 0 0 ~

~~ ~ ~ >- :>! < < 0 p.. 0- 0 ...:I~ ~ ~o

~ ~E Z ~ 9~ :>! oS ~ <~ 0 E- ~- ~ 0 ~Q)

~- .... ~ Z~ o~ 0 ...:I ~

0 < ~< <M

< ...:I .... E-.e. <~ 0 ~ ...:I ::;,...:1

0 0 t; ~ 0 -0 ~~ ~E ...:I 0 ~ 00 000 z:;s

SUB 50

Standard 2300 8400 0.283 0.920 0.618 160 0.67 Passive 1000* 4100 0.251 0.885 0.524 155 0.70 Superinsulated 500 1230 0.220 0.864 0.669 135 0.83

SUB 50 - space heat only

Standard 1800 8300 0.301 0.950 0.563 180 0.70 Passive 600 3400 0.242 0.950 0.261 190 1.40 Superinsulated 170* 920 0.223 0.950 0.238 185 2.00

SUB 1

Standard 60* 190 0.215 0.923 0.677 120 0.60 Passive 31 90 0.178 0.894 0.609 115 0.77 Superinsulated 14* 33 0.150 0.865 0.715 75 0.60

TUB 50

Standard 1200* 3800 0.268 0.897 0.661 140 0.55 Passive 750 1600 0.232 0.861 0.671 155 1.10 Superinsulated 420 800 0.224 0.869 0.738 115 0.70

HUB 200

Standard 2500* 9700 0.295 0.898 0.623 150 0.63 Conserving 1250 3200 0.244 0.857 0.684 120 0.55

*System with collector tilt equal to latitude.

63

Page 72: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I. TR-907

- 11111" - ~~~

SIMULATION RESULTS MEDFORD, OREG.

Evacuated-Tube Conector - Single--'I'ank System - ---

Q)

>t b.O co

Cl c... <: ~ z z ~

0 ~ ~

... 0 0 ~ til

~ 0 E= - Z M <: ...:I E-o ~ E ~ 0 >t 0 0

0 p:.~ ~ >- <: <: ~ 0- 0 ~ ...:I~ ~ p:. ... >t ~E ~E Z p:. <:p:. 0 ~~ E-o ~- ~- ~ 0 - ~ Z~ <:M o;Z 0 ...:I ~ 0 <: ~<: E-o-e. <: ...:I 0 S ...:I 0...:1 <: c:,)

0 0 E-o p:. 0 -0 ~~

~E ...:I 0 00 ~ 00 000 Z~

SUB 50

Standard 2200 8300 0.303 0.921 0.587 180 0.53 Passive 900* 3800 0.276 0.880 0.510 175 0.83 Superins ulated 400* 1180 0.259 0.852 0.640 145 0.67

SUB 50 - space heat only

Standard 1800* 7700 0.305 0.950 0.540 195 0.63 Passive 580 3400 0.258 0.950 0.253 190 0.90 Super ins ulated 160 900 0.235 0.950 0.237 190 1.00

SUB 1

Standard 55 180 0.244 0.920 0.642 140 0.47 Passive 27 82 0.195 0.890 0.685 95 0.77 Superins ulated 12 27 0.188 0.858 0.696 100 0.55

TUB 50

Standard noo 3600 0.291 0.889 0.623 170 0.47 Passive 600* 1950 0.274 0.850 0.632 150 0.55 Superins ulated 340 800 0.261 0.855 0.708 130 0.55

HUB 200

Standard 2400* 9000 0.305 0.896 0.594 180 0.50 Conserving 1100 3100 0.277 0.862 0.662 145 0.60

*System with collector tilt equal to latitude.

64

Page 73: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I 'l"i", TR-907 - 111.'1 - ,,~~

SIMULATION RESULTS MEDFORD, OREG.

Flat-Plate Collector - Two-Tank System

Q)

>; bD OJ

< 0 c.. ~ Z Z ~ 0

~ ~ ...

0 0 ~ Ul ~ ::> - e:: z '" < ...::! E-< ~ S ~ 0 >; C,.) C,.)

0 ~-;:;-~ >- < < ll.. 0- C,.) ~ ...::!~

~ ~o >; E-<C"I ~S Z 0 9~ oS ~ <~ E-< 0_ ~ 0 ~ Q)

~- < - ~ Z~ <'" o~ 0 ...::! ~ C,.) < ~< E-<.e. < ...::! - <C) 0 ~ ...::! ::>...::!

0 0 ~ ~ 0 15£ ~~

~S ...::! C,.) ~ a:l Z~

SUB 50

Standard 2100* 7800 . 0.323 0.941 0.595 200 0.70 Passive 1050 3900 0.260 0.935 0.552 180 0.83 Superinsulated 500 1220 0.235 0.929 0.685 165 0.83

SUB 50- space heat only

Standard 1700 7200 0.333 0.950 0.544 210 0.67 Passive 550* 3500 0.246 0.950 0.280 180 0.83 Superinsulated 180 900 0.217 0.950 0.288 180 1.00

SUB 1

Standard 55 165 0.250 0.939 0.653 160 0.55 Passive 32 86 0.176 0.932 0.630 130 0.55 Superinsulated 15 30 0.158 0.929 0.741 105 0.70

TUB 50

Standard 1150 3350 0.300 0.929 0.654 195 0.60 Passive 770 1800 0.244 0.923 0.686 170 0.90 Superinsulated 420 820 0.244 0.925 0.750 150 0.90

HUB 200

Standard 2600 7800 0.311 0.932 0.633 205 0.67 Conserving 1250 3000 0.261 0.919 0.694 170 0.83

*System with collector tilt equal to latitude.

65

Page 74: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I :. = (~I TR-907

SIMULATION RESULTS MEDFORD, OREG.

---------------"- -------------Evacuatea..-Tube-Conector---'I'w~'l'ank--System

Q,)

~ btl a:s <: Cl ~

~ Z Z ~ 0

~ ::E .....

~ ~ 0 ~ (I)

<: D - Z C"')

t-':! E-o ~ S ~ 0 ~

C,) C,) 0 ~~ ~ 0- >- <: <:

~ ~S ~S C,)

~ t-':!~ ~ ~ .....

~ Z ~ <:~ 0 ~~ E-o ~- ~- ~ 0 - ~ Z~ <:M O~ 0 t-':! ~ 0 <: ~< E-o~ <: t-':! - <~ 0 ~ t-':! Dt-':! 0 0

~ ~ 0 -0 ~~

~S t-':! C,) ~ 00 000 Z::E

SUB 50

Standard 2000* 7600 0.331 0.934 0.601 200 0.77 Passive 900* 3850 0.294 0.930 0.528 190 0.77 Superinsulated 400* 1200 0.280 0.920 0.657 175 0.70

SUB 50 - space heat only

Standard 1600* 7200 0.338 0.950 0.519 215 0.63 Passive 500* 3300 0.302 0.950 0.256 200 0.83 Superins ulated 160 880 0.235 0.950 0.267 190 1.10

SUB 1

Standard 50 160 0.272 0.940 0.631 170 0.47 Passive 25 80 0.225 0.934 0.590 160 0.77 Super ins ulated 12 27 0.200 0.924 0.720 125 0.60

TUB 50

Standard 1020* 3500 0.330 0.921 0.618 190 0.53 Passive 600* 1950 0.297 0.914 0.649 120 0.45 Superinsulated 350 800 0.282 0.916 0.730 150 0.70

HUB 200

Standard 2400* 8300 0.328 0.930 0.608 205 0.50 Conserving 1020* 3000 0.307 0.910 0.661 185 0.63

*System with collector tilt equal to latitude.

66

Page 75: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~ TR-907 - 111.111 - ~~~

SIMULATION RESULTS BISMARCK, N. DAK.

Flat-Plate Collector - Single-Tank System

Q,)

>- b.O co < 0 c..

~ Z 0 ~ ~ Z t:t: +" t:t: 9 0 ~

U)

:;J E= z CI? < ...:l E-o E 0 0 U ~

~ ~ >- >- -< < Q ~";::-~ 0- U ~ ...:l~ ~ ~o

>- E-oC'l ~E z Q 9+" U E ~ <~ E-o 0_ ~ Q ~ ~ ~- < - ~ z~ Q 0 <M Q~ ...:l ~ -< ~< E-o~ -< ...:l - < ~ 0 ~ ...:l :;J...:l 0 0

~ ~ 0 -0 ~I-:l ~E ...:l u ~ 00 Qoo z::E

SUB 50

Standard 5000 16500 0.218 0.935 0.684 113 0.70 Passive 2400 8200 0.193 0.922 0.623 118 0.83 Super ins ulated 1000 2600 0.175 0.914 0.726 91 0.70

SUB 50 - space heat only

Standard * 4000 17000 0.235 0.950 0.618 125 0.77 Passive 1000 7600 0.200 0.950 0.463 135 1.25 Sup er ins ulated 470 2000 0.170 0.950 0.445 135 1.40

SUB 1

Standard 130 360 0.168 0.935 0.749 80 0.63 Passive 70 210 0.136 0.923 0.705 66 0.50 Superinsulated 32 58 0.111 0.922 0.819 50 0.47

TUB 50

Standard 2400 7800 0.217 0.922 0.710 100 0.67 Passive 1450 4000 0.184 0.913 0.734 85 0.53 Superins ulated 800 1440 0.167 0.913 0.822 65 0.45

HUB 200

Standard 5500 17800 0.222 0.927 0.698 110 0.67 Conserving 2300 5700 0.186 0.914 0.750 90 0.60

*System with collector tilt equal to latitude.

67

Page 76: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~" TR-907 - !1I11" - ~~

SIMULATION RESULTS BISMARCK, N. DAK.

-------- Flat--Plate-Coll-ector·"'-Two--Tank-system- ---- --

(J)

~ bD ttl

< 0 ~

~ 0 ~ ~ Z Z 0::: +oJ

0::: 0 0 ~ C/l

< ~ - - Z M ~ E-o E-o ~ E

~ 0::: 0 ~ U U ~~

0- >- <: < 0 ~ U ~ ~ 0 ~ ~E ~E Z 0::: ~o::: 0 ot ~ <~ E-o ~- 0_ ~ 0 I (J)

0 < - 0::: ZO::: <M ~= ~ 0::: U < 0:::< E-o.§.

o 0 < ~ - < ~ 0 ~ ~ ~~ 0 0 E-o ~ 0 -0 ~I-;) 0:::C'l ~ U 00. ~ 00. 000. Z:;E E-o E

SUB 50

Standard 4500 14500 0.242 0.950 0.653 153 0.63 Passive 2400 8700 0.198 0.953 0.623 123 0.60 Super insulated 1000 2800 0.183 0.957 0.726 103 0.50

SUB 50 - space heat only

Standard* 3500 15750 0.266 0.950 0.574 150 0.55 Passive 1650 8000 0.198 0.950 0.470 130 0.60 Super insulated 500 2100 0.156 0.950 0.453 125 0.63

SUB 1

Standard 120 300 0.182 0.95 0.730 112 0.55 Passive 65 185 0.160 0.952 0.676 100 0.55 Superinsulated 30 55 0.122 0.955 0.804 70 0.50

TUB 50

Standard 2300 6500 0.235 0.948 0.685 150 0.67 Passive 1500 3600 0.186 0.956 0.743 113 0.70 Superinsulated 770 1520 0.176 0.961 0.810 100 0.70

HUB 200

Standard 5000 16000 0.248 0.948 0.671 146 0.60 Conserving 2200 5700 0.201 0.955 0.741 115 0.63

*System with collector tilt equal to latitude.

68

Page 77: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~ = 1.1 TR-907

SIMULATION RESULTS BISMARCK, N. DAK.

Evacuated-Tube Conecto~ - Singl~Tank System

Q)

~ bO cO

<1:1 0 =-~ 0 ~ :;E z z p::: ....

0 0 ~ til p:: :;:J ..... ..... Z M <: ...::l E-< E-< ~ E p:: 0 ~

C) C) ~';::;-~ >- <: <: 0

~ 0- C) ~ ~o E-<~ ~E

p:: ...::lP:: ot ~ U E Z ~ <:~ 0 E-< Cl_ ~ 0 I Q)

~- <: ..... P:: Zp::: ~:::I C) <t:"" 0 ...:J P:: <: p::<:

E-<-e. 00

<: ...::l ..... <1:1 ~ 0 ~ ...::l :;:J...::l 0 0

~ ~ 0 ..... 0 ~t-;)

~E ...::l U ~ 00 Om z:;s

SUB 50

Standard 4000 13500 0.272 0.933 0.648 160 0.36 Passive 1800 7200 0.251 0.922 0.597 145 0.45 Superinsulated 700 2150 0.241 0.910 0.694 122 0.43

SUB 50 - space heat only

Standard* 3500 13000 0.274 0.950 0.606 168 0.42 Passive 1300 6500 0.246 0.950 0.449 165 0.63 Superinsulated 360 1800 0.224 0.950 0.434 150 0.63

SUB 1

Standard 95 280 0.230 0.935 0.706 123 0.39 Passive 40 165 0.210 0.923 0.632 110 0.42 Superins ulated 20 48 0.174 0.906 0.783 65 0.25

TUB 50

Standard 2000 5900 0.268 0.920 0.693 143 0.39 Passive 1050 3100 0.254 0.912 0.711 115 0.42 Super insulated 550 1200 0.238 0.910 0.801 85 0.25

HUB 200

Standard 4400 14000 0.276 0.923 0.664 155 0.35 Conserving 1600 4500 0.260 0.893 0.714 120 0.60

*System with collector tilt equal to latitude.

69

Page 78: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~I,.1;, TR-907 - ~~~

SIMULATION Rm;ULTS BISMARCK, N. DAK.

~~-----~- ---------------Eva.cuated-'Pube-eoUector~-Two_'l'ank_Syst-em--~- -~---- ------------

Q)

;>i bD aj

< 0 s:.. ~ 0

~ :?J Z Z 0:: ..... 0:: 0 0 ~ tI.l

< 0 ...... ...... Z M ~ Eo-< Eo-< ~ E 0:: 0 ;>i

C) C) ~~ ~ 0- >- < < Q

~ ~E ~E

C) 0:: ~o:: ~ ~ ..... ;>i Z ~ <~- Q o~ Eo-< ~- ~- ~ Q ~ Q) ...... 0:: ZO:: Cl C) <M Cl~ ~ 0:: < 0::< Eo-<~ < ~ ...... < ~ 0 ~ ~ O~ 0 0 Eo-< ~ 0 ...... 0 ~I-:J ~E ~ C) ct:J ~ ct:J Clct:J Z22

SUB 50

Standard 3500 12250 0.310 0.945 0.610 200 0.42 Passive 1800 6400 0.282 0.948 0.615 170 0.43 Superinsulated 700 2100 0.260 0.948 0.710 140 0.39

SUB 50 - space heat only

Standard* 3000 12800 0.308 0.950 0.561 190 0.37 Passive 1300 6200 0.252 0.950 0.474 160 0.50 Superinsulated 320 1900 0.232 0.950 0.442 140 0.43

SUB 1

Standard 90 260 0.248 0.947 0.694 145 0.36 Passive 40 160 0.222 0.948 0.664 115 0.39 Super insulated 19 40 0.200 0.950 0.788 105 0.35

TUB 50

Standard 1800 5400 0.301 0.944 0.664 195 0.40 Passive 1000 3000 0.272 0.944 0.714 145 0.36 Superinsulated 530 1060 0.258 0.950 0.817 125 0.36

HUB 200

Standard 4000 13000 0.308 0.942 0.641 195 0.63 Conserving 1600 4200 0.260 0.944 0.730 155 0.40

*System with collector tilt equal to latitude.

70

Page 79: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~. TR-907

- III" - ~~

SIMULATION RESULTS ALBUQUERQUE,N.MEX.

Flat-Plate Collector - Single-Tank System

Q)

:>; b.O cO

<: Cl s:.. ~ 0

~ ?J Z Z ~ ..... ~ Q 0 ~ til

0 Z M <: ~ Eo- ~ ~ S ~ 0 :>; U U

0 ~"';:; ~ 0- >- <: <: ~ u ~ ~o :>; Eo-C"l ~S Z ~ ~~ 0 ot Eo- uS 0_ ~

~ <:~ 0 I Q)

~- <: - p:: Z~ <t:'" ~:::l 0 ~ p:: u <: p::<: S o 0 <: ~ - <: ~ 0 ~ ~ O~ ~ .......... 0 0

~ ~ 0 -0 ~"":l ~S ~ U ~ 00 000 Z::::E

SUB 50

Standard 1300 6200 0.323 0.920 0.729 123 0.17 Passive 450 680 0.263 0.908 0.836 42 0.25 Superinsulated 550 1900 0.285 0.908 0.760 95 0.14

SUB 50 - space heat only

Standard* 1000 7000 0.333 0.949 0.636 140 0.17

SUB 1

Standard 32 116 0.259 0.923 0.806 82 0.13 Semipassive 14 31 0.218 0.908 0.823 65 0.25

TUB 50

Standard 700 2300 0.306 0.901 0.798 100 0.14 Passive 450 180 0.238 0.950 0.936 150

HUB 200

Standard 1550 6400 0.318 0.908 0.769 105 0.13 Conserving 750 1300 0.272 0.902 0.849 85 0.13

*System with collector tilt equal to latitude.

71

Page 80: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I '* = I~~) TR-907

SIMULATION RESULTS ALBUQUERQUE,N.MEX.

------ - ----- - -- ---Fl8.t~PlB:te-conec"tor=-Tw~arrIrSystem ---

Q) b.O

~ Cd 0 ,:...

-< ~ 0 ~ :;E Z Z ~ +-'

0 9 ~ til

~ 0 ..... Z M -< ~ Eo-< Eo-< ~ 8 ~ 0 ~

CJ CJ ~~ ~ 0- >- CJ -< -< 0 ~ 0 ~ ~8 ~8 ~ ~~ ~ ot ~ z ~ -<~ 0

Eo-< ~- ~- ~ 0 I Q) ..... ~ Z~ ~::::l 0 ~ CJ -<M o 0

-< ~ ~ ..... -< ~-< • 8 -< ~ 0 ~ ~ O~ t'"'-0 0 Eo-< ~ 0 ...... 0 ~~ ~8 ~ CJ 00. ~ 00. 000. Z2S

SUB 50

Standard 1200 5850 0.354 0.942 0.704 165 0.14 Passive 475 960 0.265 0.958 0.888 120 0.22 Sernipassive 530 1900 0.298 0.947 0.791 100 0.22

SUB 50 - space heat only

Standard* 900 6300 0.375 0.950 0.647 150 0.19

SUB 1

Standard 30 108 0.297 0.945 0.790 120 0.15 Sernipassive 14 32 0.227 0.947 0.857 70 0.17

TUB 50

Standard 680 2150 0.334 0.940 0.797 150 0.18 Passive 400 320 0.270 0.961 0.944 70 0.25

HUB 200

Standard 1500 6000 0.344 0.944 0.762 150 0.17 Conserving 720 1500 0.300 0.946 0.864 110 0.21

*Systern with collector tilt equal to latitude.

72

Page 81: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-:CI 'l;,i~ TR-907 - 11111111 - ~~~

SIMULATION RE)ULTS ALBUQUERQUE, N.MEX.

Evacuated-Tube Conector - Single-Tank System

Q)

~ b.O a:s

<: 0 s:.. ~ Z Z ~

0 ~ ::8 +-'

9 0 ~ CIJ ~ :;:J ~ Z M <: ~ E-< ~ E ~ 0 ~

U U ~-;:; ~ >- <: <e: 0 r.'l. 0- U ~ ~~ ~ ~ 0 ~ E-<~ ~E z 0 at E-< u E 0_ ~

~ <:~ 0 I Q)

~- <: - ~ z~ ~::::I 0 U <M

~ ~ <: ~<: E-<-e.

o 0 <: ~ - <: <:.>

0 ~ ~ p~ 0 0

~ ~ 0 -0 ~"":l ~E ~ U ~ 00. 000. Z::E

SUB 50

Standard 1300 6400 0.316 0.924 0.653 170 0.14 Passive 400 880 0.292 0.896 0.808 160 0.18 Semipassive 500 2100 0.299 0.894 0.697 115 0.20

SUB 50 - space heat only

Standard* 1050 6400 0.316 0.950 0.567 190 0.21

SUB 1

Standard 32 120 0.260 0.923 0.731 130 0.15 Semipassive 13 35 0.234 0.900 0.775 90 0.18

TUB 50

Standard 700 2500 0.300 0.900 0.729 150 0.18 Passive 350 300 0.291 0.908 0.890 80 0.18

HUB 200

Standard 1600 6400 0.310 0.914 0.706 160 0.18 Conserving 675 1700 0.301 0.890 0.792 115 0.17

*System with collector tilt equal to latitude.

73

Page 82: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I ~~ TR-907 - m.111 - ~~

SIMULATION RESULTS ALBUQUERQUE,N.MEX.

-------- ----- ---Eval!uated-4'ulYe-eoftector---Two-TankSystem-----------

Cl.> b.O

~ OJ

< 0 ~

~ 0 ~ ~ Z Z p:: ~

p:: 0 0 ~ U)

< 0 ...... ...... Z M ~ Eo< Eo< ~ 8

~ ~ 0 ~ U U ~~ Pol 0- >- U < < Q

~ 0 ~ ~8 ~8 Z ~ ~~ ~ ot ~ <~ Q Eo< u_

~- ~ Q ~ Cl.> ~ ...... ~ Z~ Q ~ U <M Q~

< ~ ~ s:: < ~< E-<.e. < ~ 0 0 0 ~ o~

~ ~ 0 ...... 0 ~I-;) ~E ~ U ~ rJ:J QCI.l z:;s

SUB 50

Standard* 1200 5800 0.340 0.943 0.631 215 0.22 Passive 420 980 0.304 0.959 0.841 190 0.23 Semipassive 500 1900 0.316 0.942 0.719 145 0:25

SUB 50 - space heat only

Standard 950 6400 0.347 0.950 0.553 195 0.19

SUB 1

Standard 29 120 0.293 0.941 0.703 160 0.18 Semipassive 13 36 0.259 0.945 0.786 125 0.20

TUB 50

Standard 660 2300 0.338 0.936 0.716 205 0.20 Passive 350 420 0.307 0.955 0.904 140 0.25

HUB 200

Standard 1500 6000 0.340 0.938 0.691 205 0.20 Conserving 650 1700 0.322 0.941 0.801 165 0.25

*System with collector tilt equal to latitude.

74

Page 83: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

/.= TR-907 S=~III.I ------------------------------- ~~~

HOT WATER SYSTEMS

All systems presented here are to provide hot water only. The loads are all SUB 50 with the standard hot water load given fer the city in Fig. A-2. Systems are all at the point of unconstrained operation. Collector tilt is equal to latitude plus 10 degree.

~

< ~ 0 ~ :;:E Z Z ~

~ 0 0 ~

<C t:;:) .....

~ Z ....:l E-< ~

~ 0 ~ u u 0 ~ 0- >- u < < p... ~

~ E-<C"l ~E z ~ ....:l~ 0

E-< U E 0_ ~ ~ <~ OM ~- < ..... ~ Z~ 0 ....:l U <E

< ....:l ~ ..... < ~< 0 ~ ....:l t:;:)....:l E-<-....

0 0 ~ ~ 0 ...... 0 ~~

....:l U ~ 00 000 Z:;:E

Boston, Mass. Flat-plate collector

Single-tank system 1000 400 0.164 0.938 0.935 13 Two-tank system 1000 600 0.170 0.974 0.956 40

Boston, Mass. Evacuated-tube collector

Single-tank system 600 480 0.260 0.892 0.887 12 Two-tank system 600 480 0.273 0.937 0.906 70

Medford, Oreg. Flat-plate collector

Single-tank system 600 960 0.204 0.894 0.854 39 Two-tank system 600 960 0.220 0.961 0.877 80

Medford, Oreg. Evacuated-tube collector

Single-tank system 500 1000 0.249 0.907 0.847 54 Two-tank system 500 1000 0.265 0.964 0.868 86

Bismarck, N. Dak. Flat-plate collector

Single-tank system 800 800 0.183 0.912 0.903 14 Two-tank system 800 800 0.193 0.960 0.914 70

Bismarck, N. Dak. Evacuated-tube collector

Single-tank system 600 720 0.251 0.938 0.921 28 Two-tank system 600 720 0.262 0.978 0.935 70

75

Page 84: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~II.I ----------------------------=-=.:.-.:;--=-­-~ ~

-System Performance

. o~I-----~I----~I-----,I----~Ir----,1

0.0 1.0 2.0 3.G 4.0 S.O

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 2800, 3200: 3600, 4000, 4460~ 4800, 5200, 5600, 6000,6400.6800,7200,7600,8000

0

N

CIt .!:! en .. 0 0 -(,)

.!! (D

'0 0

0

0

0.0

Collector Storage Trade-Off

I fL 0

v v v

I 12.0

Storage Size

LOCATION: Boston, Mass.

I 13.0

3 ~10

LOAD TYPE: SUB-50, standard load, heat and hot water. SYSTEM TYPE: Flat plate collector, single tank system.

76

Page 85: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.I -------------~-----------------~ ~~

C"l

m

C C')

0 .::0 :;: (J 0 CO J.. t'--. LL - C)

CO Q) L)

J: C')

J.. CO L.~

'0 Cl en

<:"'

(;) "J

0

System Performance

1.0 2.0 3.0 I

4.0

Storage to Collector Ratio (m3/m2)

I r- n ~ •. J

Collector sizes (m2): 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000, 3200. 3400, 3600, 4000, 4500, 5000.

(., C) 0 l..(} tv)

Q) N 0 (j)

0 J.. U"') 0 !'-.. -(J Q)

'0 0

C)

0

Collector Storage Trade-Off

I I 0.0 1750.0 3500.0

Storage Size

LOCATION: Boston, Mass.

I

5250.0

LOAD TYPE: SUB-50, passive load, heat and hot water SYSTEM TYPE: Flat plate collector, single tank system

77

Page 86: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~I 181 ------------------------------- ~

o Sys~em Performance

---------------- -----------------

c 0 0

:;:: c'") (,)

(.) ca -f'-L&. -ca Cl

Q) r.D J: 0 -~ . ..,

L."

0 0 en V'

0 ")

0 I

0.0 I

1.0 I

2.0 I

3 r: . '-'

I 4.0

Stor'age to Collector Ratio (m3/m2)

I 5.0

Collector sizes (m2): 400,500,600,700,800,900, 1000, 1100,1200, 1300.

Q) N

. o o i.il N

Collector Storage Trade-Off

en o - . 00

~~~v v

8 ~~,::===::::::::::========== 04------~1-----~1-~----~1

0.0 1250.0 2500.0 3750.0

Storage Size

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, superinsulated load, heat and hot water. SYSTEM TYPE: Flat plate collector, single tank system.

78

Page 87: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.I ----------------------------~ ~~

o

CCl o . • _ C)

System. Performance

---

-(.)(0 a:s • a.. 0 u..

.---------

_1' a:s • 4)0

:t:LO a.. ci a:s '0 L'l

t/) C~

'<t'

C'.l N')

O~i-------,-------'I-------,I------,I------~I

0.0 1.0 2.0 3.0 4.0 S.D

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 2000, 2400, 2800, 3200, 3600, 4000, 4400, 4800, 5200, 5600, 6000, 7000.

4) N en a.. 0 -(.) .!! '0 ()

o

L'l

Ln

0

0 i O.G

Collector Storage Trade-Off

I I 5.5 11.0

Storage Size

I 1'3.5

3 ~10

LOCATION: Boston, Mass. LOAD TYPE: SUT-50, standard load, space heat only SYSTEM TYPE: Flat-plate collector, single tank system

79

Page 88: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

~---

- TR-907 S=~II~I-------------------------------------------------------------~ ~~

C 0 ;: (J ca ... U. -ca Q)

:E: ... ca '0 en

Q)

~ en ... 0 -(J

.!! '0 0

a

m a CD

0

r-.. 0

<.D

0

1..'1

0

v' 0

'" 0

System Performance

~---~-~- -------~ ~­

-~--

I

0.0 1.0 2.0 3.0 4.0 5.0

a 0 0 lJ'"':I to

0

0

Storage to Collector Ratio (m3/m2)

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, passive load, space heat only SYSTEM TYPE: Flat-plate collector, single tank system.

Collector Storage Trade-Off

If) -['-. ,-<

0

0

0.0 1750.0 3500.0 5250.0

Storage Size

SYSTEM TYPE: 800, 1000,1200, 1400, 1600, ,~OO, 2000, 2200, 2400,2500,3000,3500,4000.

80

Page 89: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.I --------------------------.:......:....-..:.­-~ ~~

0 System Performance

C 01

..-?~::=--:;?------- -----------

0 0 :;::

CO U tel 0 ... U. r-.... -tel 0 II)

l: to ... 0 tel '0 I.f'l

en 0

'<t'

0 "'I

0

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 200,250, 300, 400, sao, 600, 700, 800, 900, 1000.

Collector Storage Trade-Off

500.0 1000.0 storage Size

LOCATION: Boston, Mass.

1500.0

LOAD TYPE: SUB-50, superinsulated load, space heat only SYSTEM TYPE: Flat-plate collector, single tank system

81

Page 90: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~II(.i ------------------------~ ~~

TR-907

o

C IT;

o C) ;: (J (;.,

f! Cl u. _ C'-~.

as Q)

::E: ; 0

~~ L~ o

CJ r:"1

System Performance -~-- ~--------

04-------~----~------_,------_,----__,

n " ~,...J 1.0 2.0 3 r. • J 4.0

Storage to Collector Ratio (m3/m2)

5.0

Collector sizes (m2): 2800, 3200, 3600, 4000, 4400, 4800, 5200, 5600, 6000, 6400. 6800, 7200.

Q) N

US ... 0 -(J

.! '0 0

CJ

0 C) 0 m

Cl

C) 0 0 ~

CJ . 0

0.0

Collector Storage Trade-Off

4.0 8.0 12.0 3

Storage Size ~ 1 0 LOCATION: Boston, Mass. LOAD TYPE: SUB-50, standard load, heat and hot water SYSTEM TYPE: Flat-plate collector, two-tank system.

82

Page 91: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-90'1 S=~II.I --------------------------~ ~

o

IT)

c 0 o = (.() (,) e C)

u.. ['.. - C) as CD <...0 :I: ~ 0 as IJ")

"0 en co ---.

~~

C) ,,,)

0-t

System Performance

I I I I I 0.0 1.0 2.0 3.G 4.0 5.0

Storage to 'Collector Ratio (m3/m2)

Collector sizes (m2): 1200, 1400, 1600, 1800,2000,2200,2400,2600, 2800, 3000, 3200, 3400, 3600.

CD N

(j) ~

0 -Co)

.! "0 0

Collector Storage Trade-Off 0

0 0 U, <t~

0

0 L'J N N

0

0 I I 0.0 2250.0 4500.S f:i750.0

Storage Size

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, passive load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.

83

Page 92: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

5 =91 18;1--------------------------~ ~~ TR-907

a

en co .2 co - . Uo (U u: C'--; _0 (U C» L()

System Performance

:t: c:i -'~----~ L,':

00 0~

a ,., o~------~_--__ ~I'------~I------~I-____ --.1

0.0 1.0 2.0 3.G 4.0 5.0 Storage to Collector Ratio (m 3/m 2)

Collector sizes (m2): 400, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300.

C» N

en .. 0 -U .!! 0 (J

Collector Storage Trade-Off

C)

a a co

a a 0 en

a a ~--------_rl---------.I--------~I

0.0 900.0 1800. G 2700. (]

Storage Size LOCATION: Boston, Mass. LOAD TYPE: SUB-50, superinsulated load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.

84

Page 93: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~I,.il -----------------------------~ ~

System Performance

'.:.. ")

Storage to Collector Ratio (m3/m2) . .

Collector sizes (m2): 2000, 2400, 2800, 3200, 3600, 4000, 4400, 4800, 5200, 5600, 6000.

Jo-o -(.)

~ "0 o

Collector Storage Trade-Off

C")

o w -1"--------,1.------.1.-------.

:J 1 :-j 5 . C; 1 8. S 1 ~:. ~ ,=:

Storage Size

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, standard load, space heat only. SYSTEM TYPE: Flat-plate collector, two-tank system.

85

Page 94: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II:.I -------------------------------~ ~~

c o

:;:; (J

~ u.

System Performance

----1-'----,1'---'1'----,1-'----,1

1.0 2.0 3.G 4.0 5.0 Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 800, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2500,3000.

Q)

.~ en ... o -(J

.! "0 (,)

Collector Storage Trade-Off

Cl

~l

CJ

0-.;------,1"------,1'-----1 ~ ("I .J • . J 1750.S 3~OS, ~ 5250.J

Storage Size

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, passive load, space heat only SYSTEM TYPE: Flat-plate collector, two-tank system.

86

Page 95: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S;::~I I~I--------------------------------------------------------------

System Performance

Cl

--......._______ ED (T; ----C)

C t;")

0 ;: CJ (.) ca r-... -II. - L!..J ca G> C)

J: t..; .... -ca C)

"5 "",,' en C) 'J')

CJ -1- I I I I n r 'J "')

, n J • . .J

~ n c... -J 3.G 4.0 c- n ::>.J

Storage to Collector Ratio (m3/m2) Collector sizes (m2): 200, 250, 300, 400, 500, 600, 700, 800, 900, 1000.

G> .~ en -o -(.) ~ "5 o

C)

C) c:J C)

i..n Bl'

~I I

O.G

Collector Storage Trade-Off

------~----------.I----------~I

500.':1 10GO.S lSOG.O Storage Size

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, superinsulated load, space heat only, SYSTEM TYPE: Flat-plate collector, two-tank system.

87

Page 96: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II/.~~ -----------------­-~ ~ ",

c:: System Performance .-; _~~ ::W-------------- ~--1·~·· ~-~---=-~~~~---------------- ------~GJ~ U. 0 _ -as t'-_ (1) •

::t: C) -

"" ,--, as '0 D (,IJ i...!

Cl

o 1------.-1 ---l'-----,I---~-Ir------,I

(1) N

en "" o -(.) ~ '0 o

D,D 1.0 2.0 3.j 4.0 5.0

Storage to Collector Ratio (m3/m2)

SYSTEM TYPE: 2800, 3200, 3600, 4000, 4400, 4800, 5200, 5600, 6000,6400,6800.

Collector Storage Trade-Off

,-

o

0-+------.------'------,1 3.S 7.0 is.S

Storage Size 1 (~3 ~ U

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, standard load, heat and hot water SYSTEM TYPE: Evacuated tube collector, single tank system.

88

Page 97: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II*I -----------,----------------'---

CJ

l: -ca w

'0 en Cl "<!.,

Cl '-'I

System Performance

o ...JI' ___ ~'----~, .. ----,,----".----"

0_0 1.S 2.0 3.S 4.0 5.0

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 1200, 1400, 1600, 1800,2000,2200,2400,2600,2800, 3000, 3200, 3400, 3600, 3800.

CI) N

en -o -Co)

.!! '0 o

Collector Storage Trade-Off

u~

~ ~ ~~!;::::::::2:e:-==(:-' -------______ _

01·-----·-·..-, ---------1'-------, G. S 3 . ',-: 7 , 0 1 0 ._ :)

Storage Size ~ 1 03

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, passive load, heat and hot water. SYSTEM TYPE: Evacuated tube collector, single tank system.

89

Page 98: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~I r*r _____________________ T-=..:R:..:..--=.9.:::...:..07

, J

o System Performance ----------------- ='-- ~---------------------

i ~ ~-----+tr-._ ~ __ ._

~ ci ~-----------------------­~C)~ .. C'l

ftI [,Ii '0 en 0

o "'J

o~I------_.------'-------TI------'Ir------,1 0.0 1.0 2.0 3.0 4.0 5.0

Storage to Collector Ratio (m3/m~)

Collector sizes (m2): 400,500,600, 700, 800, 900, 1000, 1100, 1200, 1300.

Q) N

en .. 0 -(,) .! '0 0

- Collector Storage Trade-Off 0

0 0 L:-1 N

0

0 L:l

~ C\J

<-~ ,

0

0

0.0 1250.0 2500.0 3750.0

Storage Size

LOCATION: Boston, Mass. LOAD TYPE: SUS-50, supennsulated load, heat and hot water SYSTEM TYPE: Evacuated tube cOllector, two-tank system.

90

Page 99: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~II.I -----------------------------~ ~

-ca .... ::-: Go» :z: Ci .. i..,~

.!!! Cl 0 C/) <;t'

0 '''I

0 I r I I C.G 1.G 2.0 3.S 4.0 S.O

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 2000, 2400, 2800, 3200, 3600, 4000, 4400, 4800, 5200, 5600, 6000.

Go» N

en .. 0 -(,) .! '0 0

Collector Storage Trade-Off 0

CJ 0 0 c...~

C)

0

~ 0 0 '<t' V

v

°4----------.I----------~I·----------.1

C.G 4.0 5.0 12.0

Storage Size ~ 1 03

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, standard load, space heat only SYSTEM TYPE: Evacuated tube collector, single tank system.

91

Page 100: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~II.I ______________________ T_R-.:-9-=-07 - ~~

_______________ ~ _____ ~-~--------s:::erf~rlTl~ce~-rn---Cl ' -----C o Co') = 4 (,) CJ

e r--. U. CJ -ca l..0 CI> ::t: CJ

... L" ca '0 0

en <t'

0 "'l

0 1 1 1- 1 O.G 1.0 2.0 3.0 4.0 5.0

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 800, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2500, 3000, 3500,

CI> .~ en ... 0 -(,) .! '0 (J

Collector Storage Trade-Off

Cl

0 0 0 <t.,

Cl

0 0 0 N

0

0

D.G 2000.0 40CO.0 60[0.0

Storage Size

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, passive load, space heat only. SYSTEM TYPE: Evacuated tube collector, single tank sysTem

92

Page 101: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.I -------------------------------~ ~~

0

C r.

0 C)

;: Co'") (.)

~ (.") ~

U. r-... -~ Cl Q)

l: 1...:.-;

~ (.") ~

'0 .... (J) Cl

.;:t'

0 "l

0 i

S.S

System Performance .r=-. ___ ,.-- /' --<:(J)t;-.-----

, ,.., 1. U

I 2.0

I 7 ,.., .J ."J

/'/'

~----... -.

I 4.0

I S.O

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 200, 250, 300, 400, 500, 600, 700, 800, 900, 1000.

Q) N

en ~

0 -(.) ~ '0 0

Collector Storage Trade-Off

0

C) 0 !'--

c.")

r-'") ~l

C)

0 I I

O.S 3~O.O 700.0

Storage Size

LOCATION: Boston, Mass.

--, 1050.0

LOAD TYPE: SUB-50, superinsulated load, space heat only. SYSTEM TYPE: Evacuated tube collection, single-tank system.

93

Page 102: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II;.I -------------------------------~ ~

~~-------------

C 0 :;: CJ ca 10.

La. -ca Q)

:I: 10. ca '0 en

10. o -CJ .! o o

0

CI

Cl

In

D

['..

C)

Q

Cl

u~

(:)

'<t'

0 ~

0

--------fjjf;-

I ,., r u . ...J 1.0

System Performance -~-~------- ~ --~-~--------~--------

2.0 1

3.0 1

4.0

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 2800, 3200, 3600, 400, 4400, 4800, 5200, 5600,

6000, 6400

Collector Storage Trade-Off

Cl

~l

i~ (:)

0-+------,-------,·-----.1

0.0 3 .. '5 7.0 lO~5 , Storage Size "" 1 0"

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, standard load, heat and hot water SYSTEM TYPE: Evacuated tube collection, two-tank system.

94

Page 103: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S-~I * - ".11 - ~~~

TR-907

0 System Performance

Cl

C Cl

0 (0

::: (.) CJ ca

l'. a.. LL.

C) -ca <.D Go)

J: 0

a.. ''-' ca .... ,

'0 0

en "i"'

0 ''J

0 I I I I 0.0 1.0 2.0 3.0 4.0 5.0

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 1200,1400,1600,1800,2000,2200,2400,2600,2800,3000, 3200

Go) N

en a.. 0 -(.)

~ '0 (.)

0

0 0 Lr~ n

0

0 Ln I'.

C)

0

0.0

Collector Storage Trade~Off

I 1750.0

I 3500.0

Storage Size

I 5250.0

LOCATION: Boston, Mass.

LOAD TYPE: SUB-50 passive load, heat and hot water SYSTEM TYPE: Evacuated tube collector, two-tank system.

95

Page 104: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S::~II~~I--------------------------------------------------------~~~ -~ ~~~

c: System Performance

_____________ ~ --$~~ .. --------~~~ x___ __

c ~// . --o ~ .

::::: C) u «S t'--

"" U. C) - L..~ «S CI) Cl l:

"" li'

«S CJ "0

.;t' en Cl

'" 0

I I I I 0.0 1.0 2.0 3 I' .J 4.0 S.O

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 400,500, 600, 200, 800, 900, 1000, 1100,

CJ

D CJ 0

CI) N Cii "" CJ 0 - CJ U 0 .!! lf1

"0 0

0

0 I 0.0

Collector Storage Trade-Off

I 500.0

I 1000.0

Storage Size

I 1:;00.0

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, superinsulated load, heat and hot water. SYSTEM TYPE: Evacuated tube collector, two-tank system.

96

Page 105: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.I ----------------------------~ ~

C) System Performance ___ . -' // ,~_"1K

r.1

C 0 0

CD ::: ..-------_.-

..---CJ C) «I ...

t'-tI. . - (:) «I (1) ..0

J: 0 ... «I '''-' ..... "0 CI)

0

'<t'

0 "0

0 J 1 1 1 1 O.G 1.0 2.0 3.0 4.0 5.0

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 2000, 2400, 2800, 3200, 3600, 4000, 4400, 4800, 5200, 5600, 6000.

o \ o \ o (:) ('...

(")

Collector Storage Trade-Off

0+-----.1 -----.1----__ 1

3 c; 7.0 10.5 Storage Size ~ 1 0 3

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, standard load, spac~ heC!t 9.nly. SYSTEM TYPE: Evacuated tube collector, two-tank system.

97

Page 106: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.I -----------------------------~ ~

o

------------------- --- --GR-

.§ c~

... 0.") (.) . f!o u..r--. - ' caD CDtC l: . ... 0 ca 'n '0 u.

enD

D NJ

System Performance ---iflQ)

~ -- -----------------

O~I----,----,-----TI------~Ir---~I 0.0 1.0 2.0 3.0 4.0 5.0

Storage to C~lIector Ratio (m3/m2)

Collector sizes (m2): 800,1000,1200,1400,1600,1800,2000,2200,2400, 2500.

CD .~ en 0 ... o 0

- Ul (.) r-....

~ '0 o

o

Collector Storage Trade-Off

o~--------'l--------'I------__ ~I 0.0 1750.0 3S0C.O 5250.0

Storage Size

LOCATION: Boston, Mass. LOAD TYPE: SUB-50 passsive load, space heat only. SYSTEM TYPE: Evacuated tube collector, two-tank system.

98

Page 107: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.' -------------------------~ -~ ~

c o ;: CJ f!

LI.

... ca '0 CJ)

o System Performance ~~--/-.-/.- ---------~

/' / ~-----

O~IL------~------~I------~I-----~I-------~

O.~ 1.0 2.0 3.0 4.0 5.0 Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 200, 250, 300, 400, 500, 600, 700, 800.

CI,) N

en ... 0 -CJ ~ '0 u

C)

0 C) Cl

L;

o , .... 'J I ,,' I

I

0

0

n ~ U.J

Collector Storage Trade-Off

I 450.D

I 900.0

Storage Size

I lYiO.G

LOCATION: Boston, Mass. LOAD TYPE: SUB-50, superinsulated load, space heat only. SYSTEM TYPE: Evacuated tube collector, two-tank system~

99

Page 108: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~III.I ----------------------------~ ~

-i-___ -, ___ ----,· ___ --,I ____ '11 ___ --,1 ____ '1 ____ 1

2.0 3.~ 4.0 5.0 6.0 7.S

Storage to Collector Ratio (m3/m2)

Collector Sizes (m2): 1600,1800,2000,2400,2800,3200,3600.4000, 4400, 6800, 5200, 560q, 6000.

CD N

Cii ... 0 -(,) .! '0 ()

Collector Storage Trade-Off CJ

0

25"1 1'-.

()

(.)

0 L-t<J

()

0 1 1

0.0 3.S 7.0

Storage Size

LOCATION: Medford, Ore. LOAD TYPE: SUS-50, standard load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.

100

Page 109: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II:.I ------------------------------~ ~

°i------~'-------"------~,-------,'-------.,------,'------r J.G 1.0 2.0 3.0 4.0 S.Q ~.O 7.0

Storage to Collector Ratio (m3/m2)

Collector Sizes (m2): 800,900,1000,1250,1500,1750,2000,2250,2500,2750,3000, 3250,3500,3750,4000,4800,5600,6400,7200. -

Q,)

.~ en a-0 -(,J

.! '0 (.)

Collector Storage Trade-Off <:.:)

(.) D 0 l.C

u C) (.) 0 I""'l

C")

o"'T ----------".----------.,---------" n (' 'J .. J 3.S R.O 8.0

Storage Size ~lO 3

LOCATION: Medford, Ore. LOAD TYPE: SUS-50, passive load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.

101

Page 110: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~I t., -------------------------~ ~~

-cu C) G.I J: (~ '-'-. .. C) cu '0 L;

en 0

'<t'

0 ~

0

System Performance

--_~-=--3l .j

-------------_. __ .--_._--_._-----------

1 i ...L---,-------,-----,'-----Ir-----rl -----rl-------,1

O.G 1 r. • 'J 2.0 3.Q 4.0 5.0 S.D 7.0

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 250,300,350,400,500,600,700,800,900, 1000, 1250, 1500, 1750, 2000, 2250.

Cl

0 0 n

G.I N (i) .. 0 0 -(,) 0

~ l..'J

'0 i.D

0

0

0 I 0.0

Collector Storage Trade-Off

1

fi50.0 1

1300.0

Storage Size

I

195C.0

LOCATION: Medford, Ore. LOAD TYPE: SUS-50, superinsulated load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.

102

Page 111: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~I,i.,---------------------~ ~

0-'-__ --". ___ -,, ___ --,-,. ___ ,' ____ ---,1_ ---'1------,1

1.0 2.0 3.J 4.0 5.J 5.0 7.0 ,.., .. J • .J

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 1400, 1600, 1800, 2000, 2400, 2800, 3200, 3600, 4000, 4400, 4800, 5200, 5600, 6000.

Q) N en

C)

o D o CI

.... :)

Collector Storage Trade-Off

o -'

~ gl· '0 o

CJ

o "li--------,I.--------,I----~I 1.0 13.0 12 'J

Storage Size "'" 1 03

LOCATION: Medford. Ore. LOAD TYPE: SUB-50, standard load, space heat only. SYSTEM TYPE: Flafpiate collector, single tank system.

103

Page 112: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

5 /.~, TR-907

=~I fl." --------------------------=-=-~..:....:.... - ~

System Performance r-7'-r--:>--'?--

---/'-----------~------------

O~~~~--~~--_.------~I------'I-------,I-------'Ir------,I

3.~ 4.0 5.0 S.C 7.0

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 400, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 5000, 6000.

CD N

en

CJ

o o LFl N

... 0

'sci (,) i.,.'"1 CDN - ...... 15 o

Collector Storage Trade-Off

o

°i----------'I----------.rl---------.I ~. G 12::)0. G 250G.O 3750.0

Storage Size

LOCATION: Medford, Ore. LOAD TYPE: SUB-50, passive load, space heat only SYSTEM TYPE: Flat-plate collector, single tank system.

104

Page 113: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

- TR-907 S=~I'(_: ------------------------------

0

.-<

r;;

0 C

(~'J 0 :;:: C) u ca ['-. ... , u. C) -ca u; Q)

0 ::J: ... L.r: ca C)

"0 en '<t'

0 "'"l

0

System Performance

I 4.0

I

5.0 Storage to Collector Ratio (m3/m2)

I S.O

Collector sizes (m2): 120, 160,200,240,280,320,360,400,600,800, 1000,1200,1400,1600,1800,2000.

Collector Storage Trade-Off

0

C)

0 ['-..

Q) N

(j) ... 0

0 0 - L.r~ U t'0 ..! "0 0

0

o· I I I I n n J.-.J 350.0 700.0 1 or:o. 0

Storage Size

LOCATION: Medford, Ore. LOAD TYPE: SUB-50, superinsulated load, space heat only SYSTEM TYPE: Flat-plate collector, single tank system.

105

I 7.0

Page 114: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~I'.' ----------------------------~ ~~

-ca CJ Q)

u..' J: ~ CJ

.! 0

i..:J

en Cl

0 4,-------.-------'1-------.1-------'1-------.1 0.0 1.0 2.0 3.0 4.0 S.O

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 3500,4000,4500,5000,5500,6000,8000,10,000,12,000.

Q) N (j) ~

0 -(J

..! '0 (.)

Collector Storage Trade-Off

0

'<t'

CJ

~ r--...

<'.

"

C)

04----------r--------~·--------~1

0.0 7.0 14 n .. ~ Storage Size

LOCATION: Bismarck, N.D.

21.0 >.L 11:3

" U

LOAD TYPE: SUB-50, standard load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.

106

Page 115: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.I -------------------------~ ~

CJ System Performance

en

C CJ

0 ':"''''J ~/ ::: u 0

_ ;;;;-/-_. ::=-::-~7~-======--=-=1 ~ ~-------

ca ['-... ..

u. Cl -ca ill

CI.I :::z::: C) .. c.'"'\ ca '0 C)

en '<t'

Cl t"1

0 ~I-------~I------~I------~I-------I'------~I

0.0 1.0 2.0 3.0 4.0 S.O

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 1600, 2000, 2400, 2800, 3200, 3600, 4000, 5000, 6000, 7000.

Collector St()~~9~ _T.rad~-Off 0

Cl C) 0 ('..

CI.I N en .. C)

0 0 -u 0

~ w: '0

n

0

0

0 I I

n n 'J. ,J 3.'j 7.0

Storage Size

LOCATION: Bismarck, N.D. LOAD TYPE: SUB-50, passive load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.

107

Page 116: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S;=~II~I------------------------------------------------------------

c::: System Performance it ~~:-~.~~-~=~~- .. ----.--u.. t'-- . . - 01 as Go) CD J: co ... .!! Lj"";

0 0 en <;j-'

co .:")

0 r

0.0 I

1.0 2.0 I

3.Cl I

4.0

Storage to Collector Ratio (m3/m2)

I 5.0

Collector sizes (m2): 600,800, 1000, 1200, 1400, 1600, 1800, 2000.

Go) N

en ... 0 -U .!? '0 0

CJ

0 0 L'"l N

CJ

0 Ul N

0

0

Collector Storage Trade-Off

~ (.

0.0 1250.0 2500.0 Storage Size

I 3750.0

LOCATION: Bismarck, N.D. LOAD TYPE: SUB-50, superinsulated load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.

108

Page 117: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~I rill ------------------------------

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 3000, 3500, 4000, 4500, 5000, 5500, 6000, 8000, 10,000, 12,000, 14,000.

Collector Storage Trade-Off

Co)

'.:::J -+-____ -..1 ------.1"------.1

7.r:; is.S 2;2.5 ~

Storage Size ""lU'

LOCATION: Bismarck, N.D. LOAD TYPE: SUB-50, standard load, space heat only. SYSTEM TYPE: Flat-plate collector, single-tank system.

109

Page 118: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S;::~I It~I--------------------------------------------------------------- ~

,'-', '- ,

c 0 :;: (,) ca '-u.. -ca G)

J: c) '-ca U-,

'0 C) en ".

C) .<)

System Performance

------

" .-, 1 '-,

.J. .~ i :_1 4 " • J

Storage to .Collector Ratio (m3/m2)

Collector sizes (m2): 1200, 1600,2000,2400,2800,3200,3600,4000,5000, 6000, 7000, 8000.

Collector Storage Trade-Off

O-+!----------rl---------.I----------. J.::; 4.0 S.O 12.fJ

Storage Size

LOCATION: Bismarck, N.D.

1 (-.3

;w:: tj

LOAD TYPE: SUB-50 passive load, space heat only. SYSTEM TYPE: Flat plate collector, single tank system.

110

I 7 r,

Page 119: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~II*I ___________________________ T_R_-9_0_7

~l~~ ~~~rmanc~e c ~I ,/ /' /~ o · ... 1 ,/ :;:

~ ~ll LL -m l!"'l

l: C) .

:; ,,~

~)

~: ~ ~~~

° -::-----,1 ------,1-----,----,------. ----, ------, 1 1 -

1 -

1

J,(~ 1.G 2.0 ~ .- 4. ("I 5. (' ,), 0 7. ·oJ. "J ~ '-.'

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 400,600,800, 1000, 1200, 1400, 1600, 2000, 2400.

Go) N en .. o -(,) .! '0 o

o U C) C) n

o

Collector Storage Trade-Off

O'~ cO ~

o

O-li------'I------Ir-------l "-1 ...... 'v •. J 1500.: 30SG.~ 4500.~

Storage Size

LOCATION: Bismarck, N.D. LOAD TYPE: SUB-50, superinsulated load, space heat only. SYSTEM TYPE: Flat-plate collector, single-tank system.

III

C

Page 120: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.' -------------------------------~ ~

";-1

o ''l

o ....J1 ___ ---.. ____ -.

1· ___ --.--

1 ___ -,1 ___ ---,1

D.G 1.0 2.0 3.G 4.0 5.0 Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 1000, 1200, 1400, 1600, 1800,2000,2200.

o o o Ul ";-,

o

Collector Storage Trade-Off

04----~-.-___ -, ____ ~ 1

C.G 2250.0 4500.0 67:50.0

Storage Size "

LOCATION: Albuquerque, N.M. LOAD TYPE: SUB-50, standard load, space heat only. SYSTEM TYPE: Flat-plate collector, two-tank system.

112

Page 121: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

TR-907 S=~II.I ------------------------------~ ~~

C 0 :;: CJ ca ..

LL -ca Q)

J: .. ca 0 en

Q) N (j) .. 0 -CJ .!! 0 0

0

m

System 'Performance _--- --~::::::::::-=-:_ ..:.=---=- --'9~-

0

G:l

~-::.-:-~~------

~ =------0

r--0

l.C

C)

',", u.

0

"<t-'

0

"" 0

0 . 0 0 G:l

0

0 0 '<t'

0

0

I 1.0

I 2.0

I 3.0

I 4.0

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 300, 350, 400, 450, 500, 600.

0.0

Collector Storage Trade-Off.

400.0 600.0

Storage Size

I 1200.0

LOCATION: Albuquerque, N.M. LOAD TYPE: SUB-50, passive load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two tank system.

113

I 5.0

Page 122: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~I'*' ___________________________ ...:.T.=,:R=---..::.9..::...:....07

Q)

.~ CJ) .. o -CJ .! "0 o

°1 ___ ~1----~1---~1----~1---~1 O.S 1.e 2.0 3.0 4.0 5.0

D

o u n

o o U') lO

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 500, 600, 700, 800.

Collector Storage Trade-Off

o

°1------~-------_.I-----~1 0.0 650.0 1300.0 1950.0

Storage Size

LOCATION: Albuquerque, N.M. LOAD TYPE: SUS-50, semi-passive load, heat and hot water. SYSTEM TYPE: Flatplate collector, two tank system.

114

Page 123: UC CATEGORY: UC-59a,c SANFORD SILLMAN SERI/TR ...SERI/TR-721-907 UC CATEGORY: UC-59a,c THE TRADE-OFF BETWEEN COLLECTOR AREA, STORAGE VOLUME, AND BUILDING CONSERVATION IN ANNUAL STORAGE

S=~II.I _________________________ T_R_-_9_0_7 -~ ~

C 0

:;:: (,) ftS ... u.. -ftS C)

l: ... ftS '0 CI)

C) N u; ... o -(,) .! '0 o

0 System Performance G

0

en 0

C'-..

0

~

0

L"!

0

V'

0 N")

0 I I I I I I 0.0 1.0 2.0 3.0 4.0 5.0

a o 0..., 1:'. n

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 1200, 1400, 1600, 1800,2000,2200.

Collector Storage Trade-Off

o

o~I----------'I--------~I·--------~1 0.0 17:-jO.O 3S00.0 5250.0 Storage Size

LOCATION: Albuquerque, N.M. LOAD TYPE: SUB-50, standard load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.

115

S=~II.I _________________________ T_R_-_9_0_7 -~ ~

C 0

:;:: (,) ftS ... u.. -ftS C)

l: ... ftS '0 CI)

C) N u; ... o -(,) .! '0 o

0 System Performance G

0

en 0

C'-..

0

~

0

L"!

0

V'

0 N")

0 I I I I I I 0.0 1.0 2.0 3.0 4.0 5.0

a o 0..., 1:'. n

Storage to Collector Ratio (m3/m2)

Collector sizes (m2): 1200, 1400, 1600, 1800,2000,2200.

Collector Storage Trade-Off

o

o~I----------'I--------~I·--------~1 0.0 17:-jO.O 3S00.0 5250.0 Storage Size

LOCATION: Albuquerque, N.M. LOAD TYPE: SUB-50, standard load, heat and hot water. SYSTEM TYPE: Flat-plate collector, two-tank system.