U5.Content
Features Technical data Design / Concept Performance data U5.70 Comparison U4.70/U5.70 Performance curves U5.70 Performance data U5.100 Comparison U4.100/U5.100 Performance curves U5.100 Water vapour tolerance (explanation) Pictures …
U5. Features
Best in class / Made in Germany 7 compact model sizes from 70 up to 780 m³/h
Idealy suited for the vacuum packaging of food Optional extended operating range by VARIAIR Fastest pump-down times in direct comparison Compact dimensions Smooth surfaces for quick, easy and hygienic cleaning Oil tank with dual stage oil separation Highly efficient oil separator element Oil filter as a standard feature High efficient cooling Even a cold pump achieves fast ultimate vacuum
U5. Technical data
Ultimate pressure: 0,1 mbar abs. 2 gas ballast valves: 0,5 mbar abs. (standard)
<3 mbar abs. (optional) Water vapour tolerance: 7 mbar (standard gasballast)*
Water vapour tolerance: 50 mbar (optional gasballast)* MAP (Nitrogen, Oxygen …) variants available
(U5.70 – U5.300) IE 3 motors Lower motor power compared to main competitors
* at 85° C operating temperature
U5.70/100 Design / Concept
A-side: cooling fan in spiral housing
B-side: no shaft passage B-side: cover to guide the
cooling air as a functional and design element
Reduction of leackage risks:- one single oil pipe- one single shaft sealing ring- one single oil sight glass
Air guidance and oil return is integrated into side covers/ lids
U5.70/100 Design / Concept
Oil separator elements: 70/100 150/200 300
U5.70/100 Design / Concept
Exhaust connection: Standard (Diverting cap) Optional (Female thread)
U5.70/100 Design / Concept
Exhaust connection: Standard (Diverting cap) Optional (Female thread)
U5.70/100 Design / Concept
Gasballast: Standard delivery: Possibility to close:Gasballast always open Closed gasballast(0,5mbar) (0,1mbar)
A closed gasballast valve increases the noise level
U5.70/100 Gasballast valve
Gasballast: Standard delivery: Possibility to close:Gasballast always open Closed gasballast(0,5mbar) (0,1mbar)
A closed gasballast valve increases the noise level
U5.70/100 Gasballast valve
Performance data U5.70
BECKER U5.70:
Technical data
Airflow 50/60 Hz: 70/ 84 m³/hFinal pressure: 0,10 mbar absFinal pressure (Gasballast): 0,50 mbar absMotor power 50/60 Hz: 1,5 / 1,8 kWMotor power 50/60 Hz (>100 mbar):
Length: 660 mmWidth: 380 mmHeight: 290 mmWeight: 58 kgOil capacity: 2 l
Motor variants U5.70 (IE3 motors)
BECKER U5.70:
Standard motor voltages (IE3):
1.) e.g. Europe: 3~ 50Hz Δ230/ Y400V ± 10% (IE3)60Hz Δ265/ Y460V ± 10% (IE3)60Hz Δ230/ Y400V ± 10%
2.) e.g. USA: 3~ 60Hz YY230/ Y460V ± 10% (IE3+UL/CSA)
60Hz usable @ 208V ± 10%
3.) e.g. JP/KR/BR: 3~ 50Hz Δ200/ Y350V ± 10% 60Hz Δ220/ Y380-400V ± 10% (IE3)60Hz Δ200/ Y350V ± 10%
4.) 3~ 60Hz Δ400/ Y690V ± 10% (IE3)
U5. Comparison U4.70/U5.70
Pump types U4.70 U5.70
Length [mm] 715 (IE 2) 696 (IE 3)
Width [mm] 374 380
Height [mm] 280 289
Height + gasballast [mm] 315 289
Weight [kg] 60 (IE 2) 58 (IE 3)
Airflow [m³/h – 50/60 Hz] 63/74 70/84
Ultimate vacuum [mbar abs] 0,5/3,0 F/SA 0,1
Motor power [kW – 50/60 Hz] 2,4/3,0 1,5/1,8
Sound level [dB(A)] 67/68,5 64/67
U5.70 - power consumption
U5.70 – pump-down time, 50 Hz, closed GB
U5.70 – pump-down time, 50 Hz, open GB
U5.70 – pump-down time, 60 Hz, closed GB
U5.70 – pump-down time, 60 Hz, open GB
Performance data U5.100
BECKER U5.100:
Technical data
Airflow 50/60 Hz: 100/ 120 m³/hFinal pressure: 0,10 mbar absFinal pressure (Gasballast): 0,50 mbar absMotor power 50/60 Hz: 2,2 / 2,6 kWMotor power 50/60 Hz (>100 mbar):Length: 696 mmWidth: 380 mmHeight: 290 mmWeight: 63 kgOil capacity: 2 l
Motor variants U5.100 (IE3 motors)
BECKER U5.100:
Standard motor voltages (IE3):
1.) e.g. Europe: 3~ 50Hz Δ230/ Y400V ± 10% (IE3)60Hz Δ265/ Y460V ± 10% (IE3)60Hz Δ230/ Y400V ± 10%
2.) e.g. USA: 3~ 60Hz YY230/ Y460V ± 10% (IE3+UL/CSA)
60Hz usable @ 208V ± 10%
3.) e.g. JP/KR/BR: 3~ 50Hz Δ200/ Y350V ± 10% 60Hz Δ220/ Y380-400V ± 10% (IE3)60Hz Δ200/ Y350V ± 10%
4.) 3~ 60Hz Δ400/ Y690V ± 10% (IE3)
U5. Comparison U4.100/U5.100
Pump types U4.100 U5.100
Length [mm] 770 (IE 2) 736 (IE 3)
Width [mm] 374 380
Height [mm] 280 289
Height + gasballast [mm] 315 289
Weight [kg] 63 (IE 2) 67 (IE 3)
Airflow [m³/h – 50/60 Hz] 100/117 100/120
Ultimate vacuum [mbar abs] 0,5/3,0 F/SA 0,1
Motor power [kW – 50/60 Hz] 2,4/3,0 2,2/2,6
Sound level [dB(A)] 67,5/69 65/68
U5.100 - power consumption
U5.100 – pump-down time, 50 Hz, closed GB
U5.100 – pump-down time, 50 Hz, open GB
U5.100 – pump-down time, 60 Hz, closed GB
U5.100 – pump-down time, 60 Hz, open GB
Water vapour toleranceaccording to DIN 28 426/1 and PNEUROP
The water vapour tolerance is the maximum water vapour pressure where a vacuum pump can continuously intake and display pure water vapour under normal ambient conditions (20° C, 1013 mbar abs.).
The water vapour tolerance can be calculated from pumping speed, gas ballast volume and pump temperature.
The water vapour capacity is the maximum volume of water that a vacuum pump can continuously intake and display in form of water vapour under normal ambient conditions (20° C, 1013 mbar abs.).
Water vapour toleranceaccording to DIN 28 426/1 and PNEUROP
Influencing variables:
Ambient temperature : water vapour tolerance Pump temperature : water vapour tolerance Back pressure : water vapour tolerance Gas ballast volume : water vapour tolerance
Water vapour tolerance U5.70
BECKER U5.70:
Determined data
2 gas ballast valves: 0,5 mbar abs. (standard)<3 mbar abs. (optional)
Water vapour tolerance: 7 mbar (standard gasballast)*Water vapour capacity: 0,3 l/h (standard gasballast)*
Water vapour tolerance: 50 mbar (optional gasballast)*Water vapour capacity: 1,8 l/h (optional gasballast)*
* at 85° C operating temperature
Water vapour tolerance U5.100
BECKER U5.100:
Determined data
2 gas ballast valves: 0,5 mbar abs. (standard)<3 mbar abs. (optional)
Water vapour tolerance: 7 mbar (standard gasballast)*Water vapour capacity: 0,3 l/h (standard gasballast)*
Water vapour tolerance: 50 mbar (optional gasballast)*Water vapour capacity: 1,8 l/h (optional gasballast)*
* at 85° C operating temperature