U4.2 Capacities

Embed Size (px)

Citation preview

  • 8/12/2019 U4.2 Capacities

    1/18

    DN70520301Issue 4-4

    Nokia Siemens Networks 1 (18)

    Nokia Siemens Networks Multimedia Gateway

    MGW Release U4.2 CapacitiesProduct Documentation

  • 8/12/2019 U4.2 Capacities

    2/18

    2 (18) Nokia Siemens Networks DN70520301Issue 4-4

    The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or

    transmitted in any form or means without the prior written permission of Nokia SiemensNetworks. The documentation has been prepared to be used by professional and properlytrained personnel, and the customer assumes full responsibility when using it. Nokia SiemensNetworks welcomes customer comments as part of the process of continuous developmentand improvement of the documentation.

    The information or statements given in this documentation concerning the suitability, capacity,or performance of the mentioned hardware or software products are given as is and allliability arising in connection with such hardware or software products shall be definedconclusively and finally in a separate agreement between Nokia Siemens Networks and thecustomer. However, Nokia Siemens Networks has made all reasonable efforts to ensure thatthe instructions contained in the document are adequate and free of material errors andomissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks,explain issues which may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TOSPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES,SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESSINTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THEUSE OF THIS DOCUMENT OR THE INFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademarkof Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2010. All rights reserved.

  • 8/12/2019 U4.2 Capacities

    3/18

    Contents

    DN70520301Issue 4-4

    Nokia Siemens Networks 3 (18)

    Contents

    1 Purpose ................................................................................................ 6

    2 MGW U4.2 element level capacities.................................................... 72.1 MGW U4.2 new delivery main capacity figures ...................................... 7

    3 Plug-in unit level capacities ............................................................. 83.1 Interface signaling unit (ISU) / CCP18-C................................................ 83.2 ATM interface unit / NP8S1-A ................................................................ 93.3 ATM AAL2 switching unit A2SU (CDSP-D) .......................................... 103.4 TDM interface unit IW1S1-A and IW1S1 (IWS1) .................................. 123.4.1 IW1S1-A user plane capacity with SF20 and MX1G6-A....................... 123.4.2 IW1S1-A and IW1S1 user plane capacity with SF10 and MX622......... 133.4.3 IW1S1 user plane capacity with SF20 and MX1G6-A........................... 143.4.4 IW1S1-A and IW1S1 signalling capacity with SF10 / MX622 and

    SF20 / MX1G6-A.................................................................................. 143.5 TDM interface unit IW16P1-A (NIWU).................................................. 153.5.1 IW16P1-A user plane capacity with SF10 / MX622 and SF20 /

    MX1G6-A............................................................................................. 153.5.2 IW16P1-A signalling capacity with FS10 / MX622 and SF20 /

    MX1G6-A............................................................................................. 163.6 IP interface unit NP2GE and NP2GE-A (NPGEP) ................................ 16

  • 8/12/2019 U4.2 Capacities

    4/18

    4 (18) Nokia Siemens Networks DN70520301Issue 4-4

    Summary of changes

    Changes between issues 4-3 and 4-4:Table NPGEP capacity with different codecs (Ipv4) in chapter IP interface unit NP2GE and NP2GE-A (NPGEP) has been updated.

    Changes between issues 4-2 and 4.3:

    Table NPGEP capacity with different codecs (Ipv4) in chapter IP interface unit NP2GE and NP2GE-A (NPGEP) has been updated.

    Changes between issues 4-1 and 4-2:

    The following chapters have been modified:

    MGW U4.2 new delivery main capacity figures

    Interface signaling unit (ISU) / CCP18-C

    IP interface unit NP2GE and NP2GE-A (NPGEP)

    Changes between issues 4-0 and 4-1:

    A few misspellings corrected.

    Changes between releases U4.1 and U4.2:

    Added below Table Maximum number of AAL2 ports and maximumnumber of 9 kcps VCs / plug-in unit : *all STM-1 configured equally.

    Changes between issues 2-0 and 3-0, release 4.1:

    Table IW1S1-A subchannel usage in ETSI and ANSI environments

    (A-interface ) has been updated.

    Changes between releases U4.1 and U4.0: MX1G6 has been replaced with MX1G6-A and NP8S1 has been

    replaced with NP8S1-A.

    AAL2 termination is performed in ATM interface unit NP8S1-A.

    Up-CS bandwidth has been added to NPGEP IP-interface unit.

    Table ISU unit capacities has been updated.

  • 8/12/2019 U4.2 Capacities

    5/18

    Summary of changes

    DN70520301Issue 4-4

    Nokia Siemens Networks 5 (18)

    Chapter ATM interface unit / NP8S1-A has been updated and tableMaximum number of AAL2 ports and maximum number of 9 kcpsVCs / plug-in unit is new.

    Chapter ATM AAL2 switching unit A2SU (CDSP-D) has beenupdated.

  • 8/12/2019 U4.2 Capacities

    6/18

    6 (18) Nokia Siemens Networks DN70520301Issue 4-4

    1 PurposeThis document provides information on Nokia Siemens NetworksMultimedia Gateway (MGW) capacities on TDM, ATM and IP

    interfaces, ISU, and MGW network element level.

  • 8/12/2019 U4.2 Capacities

    7/18

    MGW U4.2 element level capacities

    DN70520301Issue 4-4

    Nokia Siemens Networks 7 (18)

    2 MGW U4.2 element level capacities2.1 MGW U4.2 new delivery main capacity figures

    The main capacity figures for MGW U4.2 new delivery are as follows:

    up to 80 000 simultaneous calls (depending on used call mix)

    3.0M BHCA (14 x active ISU)

    40 STM-1/OC-3 for TDM

    100k ATM/AAL2 ports

    160k IP ports

    960 E1/T1 (1440 E1/T1 with TDM-optimised configuration)

    600 signalling links (14 x active ISU)

    30 000 msg/s in both directions, msg routing on MTP3(b)/M3UAlevel

    25 500 msg/s in both directions on SCCP level (GT, Global titleanalysis, Multipoint Iu/A)

    19 000 msg/s in both directions with Nas Node Selection Functionin MGW

  • 8/12/2019 U4.2 Capacities

    8/18

    8 (18) Nokia Siemens Networks DN70520301Issue 4-4

    3 Plug-in unit level capacities3.1 Interface signaling unit (ISU) / CCP18-C

    Table 1. ISU unit capacities 1)

    Parameter ISU unit capacity

    Simultaneous calls 2) 13 000 (call length over 260 sec)

    BHCA 3) 215 000

    Virtual Multimedia Gateway (VMGW)

    connections within the same physicalMGW controlled by different MSSs 2)

    6 500

    AAL2 ATM ports (RNC-MGW, MGW- ATM BB)

    13 000

    AAL2 nodal function capacity 2) 6 600

    ATM and TDM equivalent links. ATMequivalent link is 500 cps and TDMequivalent link is 64 kbps

    42 x equivalent link or 1 x 2 Mbps

    CCP18-A/C (with TDM, ATM SS7, andSIGTRAN)

    2 100 msg/s in both directions, msgrouting on MTP3(b)/M3UA level, 1 750msg/s on SCCP level (GT, Global Titleanalysis), 1360 msg/s/dir with NNSF

    Sigtran signalling link selection:

    SLS bits 4

    SLS bits 5 or more

    Recommended Sigtran linkconfigurations between two nodes(load sharing)

    2, 4, 8, 16 links and ISUs (1 link / ISU)for Sigtran 4)

    1 link / active ISU for Sigtran

  • 8/12/2019 U4.2 Capacities

    9/18

    Plug-in unit level capacities

    DN70520301Issue 4-4

    Nokia Siemens Networks 9 (18)

    Parameter ISU unit capacity

    Configurable ATM link size 500 3 000 cps

    Number of VMGWs 5

    1. These can all exist simultaneously.

    2. Software static limitation: usually ISU performance (BHCA)restricts the number of simultaneous calls to 4750 (call length 80sec)

    3. ABNF coding is about 5% more laborious for ISU than ASN1 inH.248 use

    4. Example: MGW has 12 ISUs. Sigtran is configured for 8 ISUs and

    each ISU has at least one H.248 link.

    3.2 ATM interface unit / NP8S1-A

    AAL2 termination and switching is performed in NP8S1-A; A2SU isnot needed.

    The maximum number of active plug-in units per MGW is 5.

    8 x STM-1/OC-3 interfaces (8 x VC-4 ETSI/ANSI hierarchy).

    The maximum amount of shaped virtual paths (VPs) is 96 / STM-1.

    The maximum amount of non-shaped VPs is 96 / STM-1.

    The maximum virtual channel (VC) size is 23 kcps.

    Table 2. Maximum number of AAL2 ports and maximum number of 9kcps VCs / plug-in unit

    PIU AAL2 ports / PIU 9k VC / PIU 9k VC / STM-1*

    NP8S1 40 000 160 20

    NP8S1-A 50 000 200 25

    *all STM-1 configured equally

  • 8/12/2019 U4.2 Capacities

    10/18

    10 (18) Nokia Siemens Networks DN70520301Issue 4-4

    3.3 ATM AAL2 switching unit A2SU (CDSP-D)

    A2SU is used with NIP1 and NIS1/NIS1P functional units.

    Table 3. Maximum number of VCs per A2SU plug-in unit variant

    A2SU plug-inunit

    Max number of VCs

    Up to 5 kcps VCper A2SU

    Max number of VCs

    Up to 9 kcps VCper A2SU

    Max number of VCs

    Up to 13 kcps VCper A2SU

    Max number of VCs

    Up to 23 kcps VCper A2SU

    AL2S-B

    AL2S-D

    CDSP-D

    20 12 8 4

    If more VCs than what is listed in table Maximum number of VCs per A2SU plug-in unit variant are configured, the A2SU maximum portcapacity is still:

    248 AAL2 ports/VC * VC amount in table Maximum number of VCs per A2SU plug-in unit variant.

    If traffic becomes higher than the maximum port amount, ALARM 3297 AAL2 PATH CAPACITY HAS EXCEEDED RECOMMENDED LIMIT

    occurs, and more A2SU HW is needed.

    Example 1. A2SU maximum port capacity

    12 * 9kcps VC / A2SU gives 2976 AAL2 ports/A2SU. This is also themaximum A2SU throughput; if more than 12 VC/A2SU are configured connectivity increases but throughput remains the same.

    Table 4. Traffic mix in different size VC, AMR/EFR codec and 64ktransparent data ports

    VC bandwidth(kcps)

    AMR12.2k ports / VC

    64k transparentdata ports / VC

    Data call ratio %

    5 140 0 0

    5 133 1 1

    5 127 2 2

    5 104 6 5

  • 8/12/2019 U4.2 Capacities

    11/18

    Plug-in unit level capacities

    DN70520301Issue 4-4

    Nokia Siemens Networks 11 (18)

    VC bandwidth(kcps)

    AMR12.2k ports / VC

    64k transparentdata ports / VC

    Data call ratio %

    5 89 9 105 72 12 15

    5 62 14 20

    5 22 22 50

    5 0 28 100

    9 248 0 0

    9 245 3 1 *)

    9 237 5 2

    9 202 11 59 162 18 10

    9 133 23 15

    9 111 27 20

    9 40 40 50

    9 0 48 100

    11 248 0 0

    11 232 16 6.5 *)

    11 202 22 10

    11 161 29 15

    11 132 34 20

    11 50 40 50

    11 0 58 100

    13 248 0 0

    13 218 30 12 *)

    13 196 34 15

    13 160 40 20

    13 60 58 50

    13 0 70 100

    21 248 0 0

    21 166 82 33 *)

    21 97 95 50

  • 8/12/2019 U4.2 Capacities

    12/18

    12 (18) Nokia Siemens Networks DN70520301Issue 4-4

    VC bandwidth(kcps)

    AMR12.2k ports / VC

    64k transparentdata ports / VC

    Data call ratio %

    21 0 114 10023 248 0 0

    23 152 96 38 *)

    23 106 104 50

    23 0 126 100

    *) maximum traffic mix: voice+ data = 248 channels (AAL2 standardaddressing limitation)

    Table 5. Traffic mix in different size VC, AMR-WB codec

    VC bandwidth(kcps)

    AMR-WB 23.85kports / VC

    AMR-WB 12.65kports / VC

    AMR-WB 6.6kports / VC

    5.5 80 152 248

    9 140 248 248

    15.5 248 248 248

    3.4 TDM interface unit IW1S1-A and IW1S1 (IWS1)

    3.4.1 IW1S1-A user plane capacity with SF20 and MX1G6-A

    63 E1 (VC-12 in STM-1)

    84 T1 (VC-1 1 in OC-3)

    Table 6. IW1S1-A subchannel usage in ETSI and ANSI environments

    (A-interface)

    A-interface TSL/PCM TSL/VETGR TSL/IW1S1-A

    IW1S1-A (E1)

    64 kbps 31 651 1953

    IW1S1-A (T1)

    64 kbps 24 672 2016

  • 8/12/2019 U4.2 Capacities

    13/18

    Plug-in unit level capacities

    DN70520301Issue 4-4

    Nokia Siemens Networks 13 (18)

    Table 7. IW1S1-A subchannel usage in ETSI and ANSI environments(Ater interface)

    Ater interface TSL/PCM TSL/VETGR TSL/IW1S1-A

    IW1S1-A (E1)

    16 kbps 120 2520 7560

    32 kbps 60 1260 3780

    64 kbps 30 630 1890

    IW1S1-A (T1)

    16 kbps 95 2660 798032 kbps 47 1316 3948

    64 kbps 23 644 1932

    3.4.2 IW1S1-A and IW1S1 user plane capacity with SF10 / SF10E andMX622

    Table 8. IW1S1-A and IW1S1 subchannel usage in ETSI and ANSIenvironments (A-interface)

    A-interface TSL/PCM TSL/VETGR TSL/IW1S1-Aand IW1S1

    IW1S1-A andIW1S1 (E1)

    64 kbps 31 534 1602

    IW1S1-A andIW1S1 (T1)

    64 kbps 24 534 1602

    Table 9. IW1S1-A subchannel usage in ETSI and ANSI environments(Ater interface)

    Ater interface TSL/PCM TSL/VETGR TSL/IW1S1-A

  • 8/12/2019 U4.2 Capacities

    14/18

    14 (18) Nokia Siemens Networks DN70520301Issue 4-4

    Ater interface TSL/PCM TSL/VETGR TSL/IW1S1-A

    IW1S1-A (E1)

    16 kbps 120 2067 6201

    32 kbps 60 1060 3180

    64 kbps 30 517 1550

    IW1 S1-A (T1)

    16 kbps 95 2114 6342

    32 kbps 47 1046 3138

    64 kbps 23 512 1536

    3.4.3 IW1S1 user plane capacity with SF20 and MX1G6-A

    Table 10. IW1S1 subchannel usage in ETSI and ANSI environments (A-interface)

    A-interface TSL/PCM TSL/VETGR TSL/IW1S1

    IW1S1 (E1)

    64 kbps 31 534 1602IW1S1 (T1)

    64 kbps 24 534 1602

    3.4.4 IW1S1-A and IW1S1 signalling capacity with SF10 / SF10E / MX622andSF20 / MX1G6-A

    Table 11. Max number of links per IWS1

    PIU Number of 64 kbpslinks

    Number of 2 Mbps

    IW1S1-A Max 31 -

    IW1S1-A - Max 1

  • 8/12/2019 U4.2 Capacities

    15/18

    Plug-in unit level capacities

    DN70520301Issue 4-4

    Nokia Siemens Networks 15 (18)

    PIU Number of 64 kbpslinks

    Number of 2 Mbps

    IW1S1 16 -

    Notice that these numbers are valid with 0.2 Erl link load.

    3.5 TDM interface unit IW16P1-A (NIWU)

    3.5.1 IW16P1-A user plane capacity with SF10 / SF10E / MX622 and SF20

    /MX1G6-A

    Table 12. NIWU subchannel usage in ETSI and ANSI environments (A-interface)

    A-interface TSL/PCM TSL/ETGR TSL/NIWU

    NIWU (E1)

    64 kbps 31 124 496

    NIWU (T1)

    64 kbps 24 96 384

    Table 13. NIWU subchannel usage in ETSI and ANSI environments (Ater interface)

    Ater interface TSL/PCM TSL/ETGR TSL/NIWU

    NIWU (E1)

    16 kbps 120 480 1920

    32 kbps 60 240 960

    64 kbps 30 120 480

    NIWU (T1)

    16 kbps 95 380 1520

    32 kbps 47 188 752

    64 kbps 23 92 368

  • 8/12/2019 U4.2 Capacities

    16/18

    16 (18) Nokia Siemens Networks DN70520301Issue 4-4

    3.5.2 IW16P1-A signalling capacity with FS10 / MX622 and SF20 /MX1G6-A

    NIWU consists of four exchange termination group (ETGR) blocks, eachof which handles four PCMs and has its own signalling link capacity.

    Table 14. Max number of links per NIWU/ETGR

    IW16P1-A Number of 64 kbpslinks

    Number of 2 Mbps

    ETGR Max 31 -

    ETGR - Max 1

    3.6 IP interface unit NP2GE and NP2GE-A (NPGEP)

    The maximum number of active plug-in units per MGW is 6

    NPGEP: 2 x 1 000Base-T Ethernet or 2 x 1 000 Base-LXEthernet

    Table 15. NPGEP capacity with different codecs (IPv4)

    Codec Mode /Bitrateof codec(kbit/s)

    Packetizationperiod(ms)

    User data per packet(Bytes)

    IuIP and Nbinterface

    Mb, Nb (SIP-I) andAoIP interface

    Ports/ NP2GEP-A Ports / NP2GEP

    IPv4 IPv6 IPv4 IPv6 IPv4 IPv6 IPv4 IPv6

    Ether netbitrate/port

    Ether netbitrate/port

    Ether netbitrate

    Ether netbitrate

    Ports Ports Ports Ports

    For AMR:IncludingAMRpayloadheader for Mb,Nb (SIP-I),AoIP

    inter faces

    kbit/s kbit/s kbit/s kbit/s

    64 5 40 182.4 214.46 820 6 820 5 600 5 600

    64 10 80 123.2 139.2 120.0 136.0 9 100 9 100 9 100 9 100

    G.711

    64 20 160 93.6 101.6 92.0 100.0 13 650 13 650 13 650 13 6506.3 30 24 26.1 31.5 25.0 30.4 32 000 32 000 32 000 32 000G.723.

    15.3 30 20 25.1 30.4 24.0 29.3 32 000 32 000 32 000 32 000

    G.723. 6.3 30 24 26.1 31.5 25.0 30.4 32 000 32 000 32 000 32 000

  • 8/12/2019 U4.2 Capacities

    17/18

    Plug-in unit level capacities

    DN70520301Issue 4-4

    Nokia Siemens Networks 17 (18)

    Codec Mode /Bitrateof codec

    (kbit/s)

    Packetizationperiod(ms)

    User data per packet(Bytes)

    IuIP and Nbinterface

    Mb, Nb (SIP-I) andAoIP interface

    Ports/ NP2GEP-A Ports / NP2GEP

    IPv4 IPv6 IPv4 IPv6 IPv4 IPv6 IPv4 IPv6

    Ether netbitrate/port

    Ether netbitrate/port

    Ether netbitrate

    Ether netbitrate

    Ports Ports Ports Ports

    For AMR:IncludingAMRpayloadheader for Mb,Nb (SIP-I),AoIPinter faces

    kbit/s kbit/s kbit/s kbit/s

    1annex A

    5.3 30 20 25.1 30.4 24.0 29.3

    32 000 32 000 32 000 32 000

    8 10 10 67.2 83.2 64.0 80.0 14 000 14 000 11 200 11 200G.729A8 20 20 37.6 45.6 36.0 44.0 27 300 27 300 22 400 22 4008 10 10 67.2 83.2 64.0 80.0 14 000 14 000 11 200 11 200G.729

    annexB 8 20 20 37.6 45.6 36.0 44.0 27 300 27 300 22 400 22 400

    15.2 20 38 N/A N/A 43.2 51.2 27 300 27 300 22 400 22 400iLBC

    13.3 30 50 N/A N/A 32.0 37.3 32 000 32 000 32 000 32 000GSMHR

    5.6 20 14 35.2 43.2 33.6 41.628 000 28 000 22 400 22 400

    GSMFR

    13 20 33 42.8 50.8 41.0 49.228 000 28 000 22 400 22 400

    GSMEFR

    12.2 20 31 42.0 50.0 40.2 48.428 000 28 000 22 400 22 400

    4.75 20 12 13 34.4 42.4 33.2 41.2 32 000 32 000 32 000 32 0005.15 20 13 14 34.8 42.8 33.6 41.6 32 000 32 000 32 000 32 000

    5.9 20 15 16 35.6 43.6 34.4 42.4 32 000 32 000 32 000 32 0006.7 20 17 18 36.4 44.4 35.2 43.2 32 000 32 000 32 000 32 0007.4 20 19 20 37.2 45.2 36.0 44.0 32 000 32 000 32 000 32 000

    7.95 20 20 21 37.6 45.6 36.4 44.4 32 000 32 000 32 000 32 00010.2 20 26 27 40.0 48.0 38.8 46.8 32 000 32 000 32 000 32 000

    AMR

    12.2 20 31 32 42.0 50.0 40.8 48.8 32 000 32 000 32 000 32 0006.6 20 17 18 36.4 44.2 35.2 43.2 32 000 32 000 32 000 32 000

    8.85 20 23 24 38.8 46.5 37.6 45.6 32 000 32 000 32 000 32 00012.65 20 32 33 42.4 50.3 41.2 49.2

    32 000 32 000 32 000 32 00014.25 20 36 37 44.0 51.9 42.8 50.8 32 000 32 000 32 000 32 00015.85 20 40 41 45.6 53.5 44.4 52.4 32 000 32 000 32 000 32 00018.25 20 46 47 48.0 55.9 46.8 54.8 32 000 32 000 32 000 32 00019.85 20 50 51 49.6 57.5 48.4 56.4 32 000 32 000 32 000 32 00023.05 20 58 59 52.8 60.7 51.6 59.6 32 000 32 000 32 000 32 000

    AMRWB

    23.85 20 60 61 53.6 61.5 52.4 60.4 32 000 32 000 32 000 32 000

  • 8/12/2019 U4.2 Capacities

    18/18

    18 (18) Nokia Siemens Networks DN70520301Issue 4-4