Types SCR and SCR-DIndoor current transformers
Instrument transformers
Product features − 600 volt, indoor, 10 kV BIL − 25 - 400 Hertz − Primary amperes: 50 - 5000 − Mechanical rating: 180 x rated current − Thermal rating: 80 x rated current, one second − Continuous current rating factor:
2.0 @ 30°C ambient 1.5 @ 55°C ambient
ApplicationThe SCR and SCR-D current transformers are used as the source of current for relaying and metering. The deeper case SCR-D is used when high burden relaying and metering is required.
Construction featuresThe ring-type core is insulated and toroidally wound with a fully distributed secondary winding. The protective case, made of an impact-resistant polycarbonate, is ultrasonically sealed.
Secondary terminalsSecondary terminals are 8-32 brass terminal screws with hardware. Space is available for a maximum of five terminals to accommodate multi-ratio designs.
CurvesSaturation, overcurrent, ratio correction factor, and phase-angle curves are available upon request.
Test reportsIEEE test reports are stored electronically and can be e-mailed in various formats at the time of shipment.
StandardsThis unit meets all applicable IEEE and NEMA standards and is a UL Recognized Component.
Dimensions
X2X1
H1
R
5.37 [137]
8.88 [225].94 [24]
.94 [24]
8.88 [225]
10.75 [273] 45°
NAMEPLATE
10.75 [273]
3.50 [89]
Ø7.02 [178]
Ø.56 [14]3-TOTAL
#8-32 THD TAPPEDTERMINALS
Types SCR (approximate weight: 32 lbs)
X2X1
H1
5.37 [137]
8.88 [225].94 [24]
.94 [24]
8.88 [225]
10.75 [273] 45°
NAMEPLATE
10.75 [273]
Ø7.02 [178]
Ø.56 [14]3-TOTAL
#8-32 THD TAPPEDTERMINALS
7.00 [178]
Types SCR-D (approximate weight: 62 lbs)
Provided by N
ortheast Pow
er System
s, Inc. w
ww
.nepsi.com
1VA
P42
8791
-DB
Jul
y 20
13 R
ev.
B
For more information please contact: ABB Inc.Medium Voltage Distribution Components3022 NC 43 NorthPinetops, NC 27864 USA Phone: +1 252 827 3212Fax: +1 252 827 4286
www.abb.com/mediumvoltage
Note:
The information contained in this document is for general information purposes only. While ABB strives to keep the information up to date and correct, it makes no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the information, products, services, or related graphics contained in the document for any purpose. Any reliance placed on such information is therefore strictly at your own risk. ABB reserves the right to discontinue any product or service at any time.
Copyright 2004 ABB. All rights reserved.
Additional styles available upon request. Contact your ABB sales representative or call +1-252-827-3212 for more information.
UL Recognized Component; File No. E96461
Selection guide
Primary ampere rating B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
IEEE relaying
accuracyStyle
number
Type SCR (7.02" window)
50 4.8 4.8 - - - C5 9628A62G17
75 2.4 4.8 - - - C10 9628A62G18
100 2.4 4.8 - - - C10 9628A62G01
150 0.6 1.2 2.4 - - C20 9628A62G02
200 0.6 1.2 1.2 - - C20 9628A62G03
250 0.6 0.6 1.2 2.4 - C20 9628A62G04
300 0.6 0.6 0.6 1.2 2.4 C20 9628A62G05
400 0.3 0.6 0.6 1.2 2.4 C50 9628A62G06
500 0.3 0.3 0.3 0.6 1.2 C50 9628A62G07
600 0.3 0.3 0.3 0.6 1.2 C100 9628A62G08
800 0.3 0.3 0.3 0.6 0.6 C100 9628A62G09
1000 0.3 0.3 0.3 0.3 0.3 C100 9628A62G10
1200 0.3 0.3 0.3 0.3 0.3 C200 9628A62G11
1500 0.3 0.3 0.3 0.3 0.3 C200 9628A62G12
2000 0.3 0.3 0.3 0.3 0.3 C200 9628A62G13
2500 0.3 0.3 0.3 0.3 0.3 C200 9628A62G14
3000 0.3 0.3 0.3 0.3 0.3 C200 9628A62G15
4000 0.3 0.3 0.3 0.3 0.3 C200 9628A62G16
Multi-ratio, IEEE, 5 Terminal
600 0.3 0.3 0.3 0.6 1.2 C100 9628A64G01
1200 0.3 0.3 0.3 0.3 0.3 C200 9628A64G02
2000 0.3 0.3 0.3 0.3 0.3 C200 9628A64G03
3000 0.3 0.3 0.3 0.3 0.3 C200 9628A64G04
4000 0.3 0.3 0.3 0.3 0.3 C200 9628A64G05
5000 0.3 0.3 0.3 0.3 0.3 C200 9628A64G06
IEEE metering accuracy
Selection guide
Primary ampere rating B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
IEEE relaying
accuracyStyle
number
Type SCR-D (7.02" window)
50 1.2 2.4 - - - C10 9628A63G17
75 2.4 2.4 4.8 - - C20 9628A63G18
100 0.6 1.2 2.4 - - C20 9628A63G01
150 0.6 1.2 1.2 2.4 4.8 C50 9628A63G02
200 0.3 0.3 0.6 1.2 2.4 C50 9628A63G03
250 0.3 0.3 0.6 0.6 2.4 C50 9628A63G04
300 0.3 0.3 0.3 0.6 1.2 C100 9628A63G05
400 0.3 0.3 0.3 0.6 0.6 C100 9628A63G06
500 0.3 0.3 0.3 0.3 0.3 C100 9628A63G07
600 0.3 0.3 0.3 0.3 0.3 C200 9628A63G08
800 0.3 0.3 0.3 0.3 0.3 C200 9628A63G09
1000 0.3 0.3 0.3 0.3 0.3 C200 9628A63G10
1200 0.3 0.3 0.3 0.3 0.3 C400 9628A63G11
1500 0.3 0.3 0.3 0.3 0.3 C400 9628A63G12
2000 0.3 0.3 0.3 0.3 0.3 C400 9628A63G13
2500 0.3 0.3 0.3 0.3 0.3 C400 9628A63G14
3000 0.3 0.3 0.3 0.3 0.3 C400 9628A63G15
4000 0.3 0.3 0.3 0.3 0.3 C400 9628A63G16
Multi-ratio, IEEE, 5 Terminal
600 0.3 0.3 0.3 0.3 0.6 C200 9628A65G01
1200 0.3 0.3 0.3 0.3 0.3 C400 9628A65G02
2000 0.3 0.3 0.3 0.3 0.3 C400 9628A65G03
3000 0.3 0.3 0.3 0.3 0.3 C400 9628A65G04
4000 0.3 0.3 0.3 0.3 0.3 C400 9628A65G05
5000 0.3 0.3 0.3 0.3 0.3 C400 9628A65G06
IEEE metering accuracy
Provided by N
ortheast Pow
er System
s, Inc. w
ww
.nepsi.com
STANDARD CURRENTSTANDARD CURRENTTRANSFORMER MULTI-RATIO TAPSTRANSFORMER MULTI-RATIO TAPSCurrent Ratings
(A)Secondary
TapsCurrent Ratings
(A)Secondary
Taps600:5 3000:5
50:5 X2-X3 300:5 X3-X4100:5 X1-X2 500:5 X4-X5150:5 X1-X3 800:5 X3-X5200:5 X4-X5 1000:5 X1-X2250:5 X3-X4 1200:5 X2-X3300:5 X2-X4 1500:5 X2-X4400:5 X1-X4 2000:5 X2-X5450:5 X3-X5 2200:5 X1-X3500:5 X2-X5 2500:5 X1-X4600:5 X1-X5 3000:5 X1-X5
1200:5 4000:5100:5 X2-X3 500:5 X1-X2200:5 X1-X2 1000:5 X3-X4300:5 X1-X3 1500:5 X2-X3400:5 X4-X5 2000:5 X1-X3500:5 X3-X4 2500:5 X2-X4600:5 X2-X4 3000:5 X1-X4800:5 X1-X4 3500:5 X2-X5900:5 X3-X5 4000:5 X1-X5
1000:5 X2-X51200:5 X1-X5
2000:5 5000:5300:5 X3-X4 500:5 X2-X3400:5 X1-X2 1000:5 X4-X5500:5 X4-X5 1500:5 X1-X2800:5 X2-X3 2000:5 X3-X4
1100:5 X2-X4 2500:5 X2-X41200:5 X1-X3 3000:5 X3-X51500:5 X1-X4 3500:5 X2-X51600:5 X2-X5 4000:5 X1-X42000:5 X1-X5 5000:5 X1-X5
Current Transformer Standard Burden Characteristics(60 Hz and 5 Ampere Secondary)
BurdenDesignation
ResistanceOhms
InductanceMillihenrys
ImpedanceOhms Volt-Amperes Power
Factor
Metering BurdensB-0.1 0.09 0.116 0.1 2.5 0.9B-0.2 0.18 0.232 0.2 5.0 0.9B-0.5 0.45 0.580 0.5 12.5 0.9B-0.9 0.81 1.040 0.9 22.5 0.9B-1.8 1.62 2.080 1.8 45.0 0.9
Relaying BurdensB-1 0.5 2.3 1.0 25 0.5B-2 1.0 4.6 2.0 50 0.5B-4 2.0 9.2 4.0 100 0.5B-8 4.0 18.5 8.0 200 0.5
BURDEN STANDARDSBURDEN STANDARDS
Voltage Transformer Standard Burden Characteristics
Burden Designation Secondary Volt-Amperes Burden Power Factor
W 12.5 0.10X 25.0 0.70M 35.0 0.20Y 75.0 0.85Z 200.0 0.85
ZZ 400.0 0.85
136
Ref: IEEE Std. C57.13 - 1993, Table 8
Provided by N
ortheast Pow
er System
s, Inc. w
ww
.nepsi.com
Produc
t Bull
etin:
42-87
9
Curves
Ref
er to
Pric
e Li
st 4
2-80
0 fo
r m
ore
info
rmat
ion
Ja
nuar
y 20
01
ABB Power Distribution 655 Century Point Lake Mary, FL 32476 Tel: + 1-800-929-7947 Fax: + 1-407-732-2132 www.abb.com/distribution
Provided by N
ortheast Pow
er System
s, Inc. w
ww
.nepsi.com