PRIMERGY RX300 S3 Server Options Guide Edition April 2007

Tx300 s3 Options

Embed Size (px)

Citation preview

Page 1: Tx300 s3 Options

PRIMERGY RX300 S3Server Options Guide

Edition April 2007

Page 2: Tx300 s3 Options

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to [email protected].

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2007 Fujitsu Siemens Computers GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

Page 3: Tx300 s3 Options

RX300 S3 Options Guide

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Overview of the documentation . . . . . . . . . . . . . . . . . 7

1.2 Options and upgrade . . . . . . . . . . . . . . . . . . . . . 10

1.3 Notational conventions . . . . . . . . . . . . . . . . . . . . 12

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . 15

4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

4.1 Removing the server form the rack . . . . . . . . . . . . . . 21

4.2 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 23

5 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 25

5.1 Memory module population . . . . . . . . . . . . . . . . . . 25

5.2 Upgrading/replacing the main memory . . . . . . . . . . . . 28

6 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

6.1 Installing a second processor . . . . . . . . . . . . . . . . . 33

6.2 Replacing the processor . . . . . . . . . . . . . . . . . . . . 38

6.3 Replacing the processor heat sink . . . . . . . . . . . . . . 42

7 ROMB (RAID on Motherboard) . . . . . . . . . . . . . . . . 43

7.1 Installing the ROMB upgrade kit . . . . . . . . . . . . . . . 43

Page 4: Tx300 s3 Options

Options Guide RX300 S3

Contents

8 Accessible drives . . . . . . . . . . . . . . . . . . . . . . . . 47

8.1 Installing a FD drive . . . . . . . . . . . . . . . . . . . . . . . 48

8.2 Installing a LocalView module . . . . . . . . . . . . . . . . . 53

8.3 Installing the CD/ DVD-ROM drive . . . . . . . . . . . . . . . 57

8.4 Tape drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

9 PCI slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

9.1 Installing a PCI controller in a low-profile slot . . . . . . . . . 66

9.2 Installing the PCI controller in the riser card . . . . . . . . . 68

10 External serial interface . . . . . . . . . . . . . . . . . . . . . 75

10.1 Installing the external serial interface . . . . . . . . . . . . . 75

11 Parallel interface . . . . . . . . . . . . . . . . . . . . . . . . . 83

11.1 Installing a parallel interface . . . . . . . . . . . . . . . . . . 83

12 Converting from low-profile to standard PCI Slots . . . . . . 91

12.1 Removing lp slot cage . . . . . . . . . . . . . . . . . . . . . 91

12.2 Converting the air duct . . . . . . . . . . . . . . . . . . . . . 94

12.3 Installing the riser . . . . . . . . . . . . . . . . . . . . . . . . 98

13 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

13.1 Closing the server . . . . . . . . . . . . . . . . . . . . . . . 101

14 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

14.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

14.2 Configuration diagram . . . . . . . . . . . . . . . . . . . . 108

Page 5: Tx300 s3 Options

RX300 S3 Options Guide

Contents

14.2.1 Configuration with 3.5“ HDDs . . . . . . . . . . . . . . . . . . 10814.2.2 Configuration with 2.5“ HDDs . . . . . . . . . . . . . . . . . . 109

14.3 Hard disk mirroring . . . . . . . . . . . . . . . . . . . . . . . 110

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

Page 6: Tx300 s3 Options

Options Guide RX300 S3

Contents

Page 7: Tx300 s3 Options

RX300 S3 Options Guide 7

1 IntroductionThe PRIMERGY RX300 S3 server is an Intel-based server for mid-size networks and large companies. The server is suitable for use as a file server and also as an application, information or Internet server.

The PRIMERGY RX300 S3 server offers a high level of reliability and availability through highly developed hardware and software components. These include hot-plug hard disk drive modules, redundant CPU fans, system fans and power supply units, and hot-plug PCI slots, the ServerView Suite server management software, „Prefailure Detection and Analysing“ (PDA) and „Automatic Server Reconfiguration and Restart“ (ASR&R).

Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation. Additional security is provided by the lockable rack door.

The rack model occupies 2 height units (HU) in the rack.

1.1 Overview of the documentation

I PRIMERGY manuals are available in PDF format on the ServerBooks CD which is supplied in the ServerView Suite package for every server system.

These PDF files can also be downloaded free of charge from the Internet: at http://manuals.fujitsu-siemens.com you will find an overview page with the online documentation available on the Internet. You can go to the PRIMERGY Server documentation by clicking on “industry standard servers”.

Concept and target groups

This Options Guide shows you how you can expand and upgrade the server.

I The Operating Manual for the server describes how you install/remove the hot-plug components.

The activities described in this manual may only be performed by specialist personnel with technical training.

Page 8: Tx300 s3 Options

8 Options Guide RX300 S3

Overview of the documentation Introduction

Additional server documentation

To the PRIMERGY RX300 S3 documentation set belong the following additional manuals:

– “Safety notes and other important information” manual (print version supplied with the system, PDF file available on the ServerBooks DVD supplied)

– “Returning used devices” manual (PDF file available on the ServerBooks DVD supplied)

– “Warranty” manual (print version supplied with the system, PDF file available on the ServerBooks DVD supplied)

– “PRIMERGY RX300 S3Server Server Operating Manual“ (PDF file available on the ServerBooks DVD)

– Technical Manual for the system board D2119 (PDF file available on the ServerBooks CD)

– “BIOS Setup” (PDF file available on the ServerBooks DVD supplied)– „ServerView Suite“ enthält die ServerStart-Disc 1, die ServerStart-Disc 2

und die ServerBooks-DVD. Die PDF-Version des Benutzerhandbuchs „PRIMERGY ServerView Suite - ServerStart“ ist auf der ServerBooks-DVD verfügbar.

I Eine Ersatz-ServerBooks-DVD kann unter Angabe Ihrer Rechnerdaten über folgende Email-Adresse bestellt werden: [email protected]

I If you need a backup of the ServerBooks-CD send the details of your server via email address: [email protected].

– “Global Array Manager Client Software User’s Guide” (PDF file available on the ServerBooks DVD)

– “Global Array Manager Server Software User’s Guide” (PDF file available on the ServerBooks DVD)

– “Integrated Mirroring User’s Guide” (PDF file available on the ServerBooks DVD)

I If you need a backup of the ServerBooks-DVD send the details of your server via email address: [email protected].

Further sources of information:

– technical manual for the rack– manual for the monitor– server management manual ServerView

Page 9: Tx300 s3 Options

RX300 S3 Options Guide 9

Introduction Overview of the documentation

– manual for the Remote Test and Diagnostic System RemoteView– in the documentation for the boards and drives– operating system documentation– information files of your operating system

(see also chapter “Related publications” on page 117)

Page 10: Tx300 s3 Options

10 Options Guide RX300 S3

Options and upgrade Introduction

1.2 Options and upgrade

Second processor

The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have the same clock frequency and the same cache as the first processor.

Upgrading of the main memory

The eight slots for the main memory are suitable for FBD533/PC2-4200F or FBD667/PC2-5300 Fully Buffered DIMM memory modules. The organization in two memory banks, 1 and 2 with 4 memory modules each, permits rapid memory access with four-way interleaving.

Memory modules must always be incorporated in pairs.

ROMB (RAID on motherboard)

The System is extended with an on board Intel I/O processor. If the controller is activated, it supports RAID Level 0, 1, 10, 5 and 50. "MegaRaid PCI Express™ ROMB" can be activated with two different upgrading kits.

Additional accessible drives

One 5.25-inch bay and one 3,5-inch bay are available for accessible drives.

The 5.25-inch bay can be installed with a 3.5 inch x 0.5 inch floppy disk drive or a LocalView module and the other bay can be installed with a 5.25-inch x 0,5 inch DVD-ROM drive.

Only for a 3.5“ HDD variant a tape drive can be installed optionally in the left drive cage (see also the configurator under “Related publications” on page 117). Two mounting locations are occupied as a result in the drive cage which are then no longer available for HDD modules.

Page 11: Tx300 s3 Options

RX300 S3 Options Guide 11

Introduction Options and upgrade

LocalView module (alphanumeric system display)

The LocalView module provides you with the option of displaying system infor-mation and hardware system faults alphanumerically. This is an intelligent module with a micro-controller and its own memory, which functions indepen-dently of the server system.

The LocalView module consists of an LCD display panel and a toggle switch, both accommodated in a suitable mount. The mechanical mechanism used allows the LCD display panel to be pulled out and flapped out. Further infor-mation on operating the display modes are provided in the documentation on the LocalView module.

Hard disk drives

The server has two drive cage that can accommodate up to six (2x3) SAS/SATA hard disk drive modules or up to twelve (2x6) SAS hard disk drive modules. Each hard disk drive module (HDD module) can accommodate a SAS/SATA or SAS hard disk drive with a maximum height of 1 inch. The module is connected to the SAS/SATA backplane without cables. This allows hard disk drive modules to be simply plugged in or pulled out. (for further details see operating manual).

The hard disk drive system is designed for SAS/SATA with a seperate channel for each of the hard disk drives.

If the server has a corresponding RAID configuration, defective HDD modules can also be exchanged online (hot-swap).

Additional controllers in non-hot-plug PCI slots

The system board offers five PCI slots. Slots 1-3 are non-hot-plug PCI slots with a PCI bus speed of 100 MHz. If slot 1 and slot 2 are not occupied, slot 3 can work with the PCI bus speed of 133 MHz (IDoubleOP™).

PCI slots 4 and 5 are hot-plug PCI slots which can be equipped with controllers that have hot-plug capability (the hot-plug PCI slots are described in the Operating Manual).

Optional riser card

Optionally you can install a Riser card into slot 5, which can be equipped with 3 controllers. The bus speed is 100 MHz. Two slots (6 and 7) can be equipped with short standard PCI controllers and slot 8 can be equipped with a full length full height PCI controller.

Page 12: Tx300 s3 Options

External serial interface

The external serial interface can optionally be made available externally.

External parallel interface for printers

As an option, a parallel interface can be provided for printers.

1.3 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands, menu items or software programs.

„Quotation marks“ indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Table 1: Notational conventions

Page 13: Tx300 s3 Options

RX300 S3 Options Guide 13

2 ProcedureV CAUTION!

The actions described in these instructions should only be performed by technical specialists or service personnel. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized opening and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability.

Ê First of all please familiarize yourself with the safety instructions in the chapter “Safety notes” on page 15.

Ê Ensure that all required manuals (see “Additional server documentation” on page 8) are available, printing out the PDF files if necessary. You will definitely need the Operating Manual for the server and the Technical Manual for the system board.

Ê Shut down the server correctly, switch it off, pull out the power plug, and open the server as described in the chapter “Preparation” on page 21.

Ê Extend or upgrade your server as described in the relevant chapter.

I The Operating Manual for the server describes how you install/remove the hot-plug components.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Ê Start the operating system and, if necessary, configure it as required (see the Operating Manual).

Page 14: Tx300 s3 Options
Page 15: Tx300 s3 Options

RX300 S3 Options Guide 15

Safety notes

3 Safety notesI The following safety notes are also provided in the “Safety notes and

other important information” manual.

This device complies with the relevant safety regulations for data processing equipment.

If you have any questions about where you can set up the device, contact your sales outlet or our customer service team.

V CAUTION!

The actions described in these instructions should only be performed by technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability.

Before operating the device

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

Page 16: Tx300 s3 Options

16 Options Guide RX300 S3

Safety notes

Installation and operation

V CAUTION!

● If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector

● The server automatically sets itself to a voltage in the range of 100 V to 240 V. Make sure that your local voltage is within this range

● This device has a specially approved power cable and must only be connected to a grounded insulated socket.

● Ensure that the power socket on the device or the grounded wall outlet is freely accessible.

● The ON/OFF button does not disconnect the device from the mains voltage. To disconnect the line voltage completely, remove the power plug(s) from the grounded insulated socket(s).

● Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the peripheral device (e.g. storage subsystem) has failed during a power outage.

● Data cables to peripheral devices must be adequately shielded.

● To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174-1/2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC 11801 are to be considered.

● Route the cables in such a way that they do not form a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.

● Never connect or disconnect data transmission lines during a storm (lightning hazard).

Page 17: Tx300 s3 Options

RX300 S3 Options Guide 17

Safety notes

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign matter), switch off the device immediately, remove the power plug(s) and contact your sales outlet or customer service team.

● Make sure that no objects (such as bracelets or paper clips) fall into or liquids spill into the device (risk of electric shock or short circuit).

● Proper operation of the device (in accordance with IEC 60950/EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan-sions, you may damage the system or violate the safety regulations and regulations governing RFI suppression. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet.

● The components marked with a warning label (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. The hot-plug power supply units are exceptions to this rule.

● The warranty expires if the device is damaged during the installation or replacement of system expansions.

● You may only set those resolutions and refresh rates specified in the „Technical data“ section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre.

Page 18: Tx300 s3 Options

18 Options Guide RX300 S3

Safety notes

Batteries

V CAUTION!

● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board D1889/D2089).

● Do not throw batteries into the trash can. They must be disposed of in accordance with local regulations concerning special waste.

● The battery must be disposed of in accordance with local regulations concerning special waste.

● Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board (see “Related publications” on page 117). If possibly inserted auxiliary boards contain batteries/accus the appropiate references in the associated manuals are to be considered

● All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:

Cd Cadmium Hg Mercury Pb Lead

Notes on handling CDs and CD-/DVD-ROM drives

V CAUTION!

● Use only CDs in proper condition in the CD-/DVD-ROM drive of your server to prevent data loss, damage to the device and injuries.

● Therefore, check each CD for damage, cracks, breakage etc. before inserting it in the drive.

Please note that any additional labels applied may change the mechanical properties of a CD and cause imbalance.

Damaged and imbalanced CDs can break at high drive speeds (data loss).

Page 19: Tx300 s3 Options

RX300 S3 Options Guide 19

Safety notes

Under certain conditions sharp-edged pieces of broken CDs can penetrate the cover of the drive (damage to the device) and be thrown out of the device (danger of injury, particularly on uncovered body parts such as the face or neck).

I You protect the CD-/DVD-ROM drive and prevent mechanical damage, as well as premature wearing of the CDs, by observing the following suggestions:

– Only insert the CDs in the drive when needed and remove them after use.

– Store the CDs in suitable sleeves.– Protect the CDs from exposure to heat and direct sunlight.

Note about the laser

The CD-/DVD-ROM drive is classified for laser class 1 according to IEC 60825-1.

V CAUTION!

The CD-/DVD-ROM drive contains a laser diode (LED). Sometimes the LED produces a stronger laser beam than laser class 1. Direct view into this laser beam is dangerous.

Never remove parts of the CD-/DVD-ROM drive assembly!

Page 20: Tx300 s3 Options

20 Options Guide RX300 S3

Safety notes

Modules with electrostatic-sensitive components

Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label:

Figure 1: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

● Remove the power plug(s) from the power socket(s) before inserting or removing components containing ESDs.

● You must always discharge yourself of static charges (e.g. by touching a grounded object) before working.

● The equipment and tools you use must be free of static charges.

● Only touch the components at the positions highlighted in green (touch points).

● Do not touch any exposed pins or conductors on a component.

● Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

● Place all components on a static-safe base.

I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN 61340-5-1, ANSI/ESD S20.20).

Page 21: Tx300 s3 Options

RX300 S3 Options Guide 21

4 PreparationV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

4.1 Removing the server form the rack

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the sever, press the on/off switch.

Ê Pull all power connectors out of the power outlets.

Figure 2: Loosening the knurled screws

Ê Loosen the four knurled screws (1) and pull the server as far as possible out of the rack.

Page 22: Tx300 s3 Options

22 Options Guide RX300 S3

Removing the server form the rack Preparation

Depending on how accessible the server is in the rack cabinet, it can make sense to remove it from the cabinet. If you do not want to remove the server from the rack cabinet, please skip this page.

Figure 3: Removing the server from the rack cabinet

Ê Disconnect all cables on the rear of the server.

Ê Pull the server outward as far as it will go (1), release the hooks (2), then pull out the Server completely.

V CAUTION!

At least two people are needed to lift the server out of the rack cabinet.

Page 23: Tx300 s3 Options

RX300 S3 Options Guide 23

Preparation Opening the server

4.2 Opening the server

Figure 4: Removing the top cover

Ê Pess the two locking buttons (1) downward and remove the cover (2).

Ê Slide the cover to the rear side and remove it (2).

2

1

12

Page 24: Tx300 s3 Options
Page 25: Tx300 s3 Options

RX300 S3 Options Guide 25

5 Main memoryV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

The system board supports up to 32 Gbytes of main memory. 8 slots (2 memory banks with 4 slots each) are provided for the main memory. Each memory bank is equipped with two 512-Mbyte, 1-Gbyte, 2-Gbyte or 4-Gbyte FBD533/PC2-4200F or FBD667/PC2-5300 Fully Buffered DIMM memory modules.

A memory bank can optionally be configured as a hot-spare bank.

ECC with memory scrubbing and with the Single Device Data Correction (SDDC, Chipkill) function is standard.

5.1 Memory module population

Figure 5: Structure of the main memory in memory banks and memory modules

– The memory modules have to be based on FBD533/PC2-4200F oder FBD667/PC2-5300F Fully Buffered DIMM-Modules and must be populated in pairs

– Each pair must consist of identical memory modules (2-way Interleaved-mode).

– The memory module capacity can differ for the various memory banks: e.g. memory bank 1A/1B can be equipped with two 512-Mbyte memory modules, and memory bank 2A/2B with two 1-Gbyte memory modules.

DIMM-2C

DIMM-1C

DIMM-2B

DIMM-1B

DIMM-2A

DIMM-1A

DIMM-2D

DIMM-1D

Page 26: Tx300 s3 Options

26 Options Guide RX300 S3

Memory module population Main memory

– Only single ranked modules are permitted.

The following table shows the required memory population sequence:

Figure 6: Schema Memory Mirroring

Memory mirroring

Either 4 or 8 identical memory modules are required for memory mirroring:

Module pair1A/1B

Module pair1C/1D

Module pair2A//2B

Module pair2C/2D

populated empty empty empty

populated populated empty empty

populated populated populated empty

populated populated populated populated

Memory bank

3 2 1 0

Channel (module)

A B A B A B A B

population 4 identical memory modules - -

4 identical memory modules 4 identical memory modules

Memory Controller

(Blackford MCH)

Channel A

Branch 0

Channel B Channel C

Branch 1

Channel D

Bank 1

Bank 2

Bank 1

Bank 2

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

Memory Controller

(Blackford MCH)

Channel A

Branch 0

Channel BChannel A

Branch 0

Channel B Channel C

Branch 1

Channel DChannel C

Branch 1

Channel D

Bank 1

Bank 2

Bank 1

Bank 2

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

FB-DIMM

Page 27: Tx300 s3 Options

RX300 S3 Options Guide 27

Main memory Memory module population

Figure 7: Diagram Memory Mirroring

I For more information see BIOS-Setup manual (see chapter “Related publications” on page 117).

Logical ViewPhysical View

Memory Population

Logical ViewPhysical View

Memory Population

Memory

Controller

(Blackford

MCH)

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FBD 1A

FBD 2A

FBD 1B

FBD 2B

FBD 2C

FBD 2D

FBD 1C

FBD 1D

FB-DIM M

Memory Controller

(Blackford MCH)

Channel 0

Branch 0

Channel 1 Channel 2

Branch 1

Channel 3

FB-DIM M

FB-DIM M ( Spare )

FB-DIM M

FB-DIM M ( Spare )

FB-DIM M

FB-DIM M ( Spare )

FB-DIM M

FB-DIM M ( Spare )

Memory Controller

(Blackford MCH)

Channel 0

Branch 0

Channel 1Channel A

Branch 0

Channel B Channel 2

Branch 1

Channel 3Channel C

Branch 1

Channel D

Bank 1

Bank 2

Bank 1

Bank 2

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M (M )

FB-DIM M ( M )

FB-DIM M (M )

FB-DIM M ( M )

M irroring

M irroring

ChA

Branch 0

ChB ChC

Branch 1

ChD

Logical ViewPhysical View

Memory Population

Logical ViewPhysical View

Memory Population

Memory

Controller

(Blackford

MCH)

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FBD 1A

FBD 2A

FBD 1B

FBD 2B

FBD 2C

FBD 2D

FBD 1C

FBD 1D

FBD 1A

FBD 2A

FBD 1B

FBD 2B

FBD 2C

FBD 2D

FBD 1C

FBD 1D

FB-DIM M

Memory Controller

(Blackford MCH)

Channel 0

Branch 0

Channel 1Channel 0

Branch 0

Channel 1 Channel 2

Branch 1

Channel 3Channel 2

Branch 1

Channel 3

FB-DIM M

FB-DIM M ( Spare )

FB-DIM M

FB-DIM M ( Spare )

FB-DIM M

FB-DIM M ( Spare )

FB-DIM M

FB-DIM M ( Spare )

Memory Controller

(Blackford MCH)

Channel 0

Branch 0

Channel 1Channel A

Branch 0

Channel B Channel 2

Branch 1

Channel 3Channel C

Branch 1

Channel D

Bank 1

Bank 2

Bank 1

Bank 2

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M

FB-DIM M (M )

FB-DIM M ( M )

FB-DIM M (M )

FB-DIM M ( M )

M irroring

M irroring

ChA

Branch 0

ChB ChC

Branch 1

ChDChA

Branch 0

ChBChA

Branch 0

ChB ChC

Branch 1

ChD

Page 28: Tx300 s3 Options

28 Options Guide RX300 S3

Upgrading/replacing the main memory Main memory

5.2 Upgrading/replacing the main memory

Ê Open the server as described in the chapter “Safety notes” on page 15.

Removing the air duct over the main memory and the processors

Figure 8: Removing the air duct over the main memory and the processors

Ê Lift out the air duct over the main memory.

Page 29: Tx300 s3 Options

RX300 S3 Options Guide 29

Main memory Upgrading/replacing the main memory

Installing mermorymodules

Figure 9: populating memory module slots

Figure 10: Removing a memory module

Ê Press the holders on either side of the mounting location concerned outward (1).

Ê Pull the memory module out of the mounting location (2).

Page 30: Tx300 s3 Options

30 Options Guide RX300 S3

Upgrading/replacing the main memory Main memory

Figure 11: Inserting a memory module

Ê Press the holders on either side of the mounting location concerned outward.

Ê Insert the memory module in the mounting location (1) until the holders at the sides engage (2).

Page 31: Tx300 s3 Options

RX300 S3 Options Guide 31

Main memory Upgrading/replacing the main memory

Inserting air duct

Figure 12: Installing the air duct over the memory and processors

Ê Reinstall the air duct over the memory and the processors.

Page 32: Tx300 s3 Options

32 Options Guide RX300 S3

Upgrading/replacing the main memory Main memory

Figure 13: Installing of the air duct

V CAUTION

When you install the air duct take care of the heat sink fins and the condensers in the marked area.

Make sure that the fins over the memory are not twisted and lie flat on the memory

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 33: Tx300 s3 Options

RX300 S3 Options Guide 33

6 ProcessorsV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

V CAUTION!

Processors are modules which can react extremely sensitively to electro-static discharges and which must therefore always be handled with care. After a processor has been removed from its protective sleeve or from its socket, place it with its smooth side down on a non-conducting, antistatic surface. Never push a processor over a surface.

6.1 Installing a second processor

The system board can be upgraded with a second processor. The upgrade kit consists of a processor, and a heat sink.

V CAUTION!

Only processors of the same type may be used on the system board. The second processor must have the same clock frequency and the same cache as the first processor. For dual operation, use a suitable multipro-cessor operating system.

Ê Open the server as described in the chapter “Preparation” on page 21.

Ê Remove the air duct over the main memory (see chapter “Main memory” on page 28).

Page 34: Tx300 s3 Options

34 Options Guide RX300 S3

Installing a second processor Processors

Figure 14: Removing processor dummy module

Ê Pull the processor dummy out.

V CAUTION!

Keep the dummy cover for future use. If you remove the processor again and do not replace it with a new one, reinstall the dummy cover to ensure that the system is cooled properly.

Page 35: Tx300 s3 Options

RX300 S3 Options Guide 35

Processors Installing a second processor

Figure 15: Empty processor slot

Ê Release the socket lever and pull it upward as far as it will go.

Ê Open the cover.

Figure 16: Opening the processor socket

Page 36: Tx300 s3 Options

36 Options Guide RX300 S3

Installing a second processor Processors

Figure 17: Inserting the processor

Ê Position the new processor over the socket and then carefully press it into the socket.

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners. To avoid damaging the pins or the processor, do not force it into the socket.

Ê Lock the processor in the socket by returning the socket lever to its original position.

I When you close the the socket lever, the protective cover will disengage itself.

Page 37: Tx300 s3 Options

RX300 S3 Options Guide 37

Processors Installing a second processor

Figure 18: places of the springs round the heat sink support pins

Ê Check whether the springs round the heat sink support pins are aligned centrally.

Ê Remove the protective cover on the underside of the heat sink.

Figure 19: Installing heat sink

Page 38: Tx300 s3 Options

38 Options Guide RX300 S3

Replacing the processor Processors

Ê Place the heat sink on the processor.

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

V CAUTION!

Never install a processor without a heat sink as otherwise the processor may overheat, causing a shut-down of the system.

Ê Reinstall the ventilation duct over the memory and processors.

V CAUTION!

Ensure a correct fit of the airduct and that no damage is caused to the cables

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

6.2 Replacing the processor

V CAUTION

Only processors of the same type may be used on the system board. The second processor must have the same clock frequency and the same cache as the first processor. For dual operation, use a suitable multipro-cessor operating system.

Ê Open the server as described in the chapter “Preparation” on page 21.

Ê Remove the air duct over the main memory (see chapter “Main memory” on page 28).

Page 39: Tx300 s3 Options

RX300 S3 Options Guide 39

Processors Replacing the processor

Figure 20: Removing the heat sink

Ê Loosen the four screws in a crossover pattern.

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Page 40: Tx300 s3 Options

40 Options Guide RX300 S3

Replacing the processor Processors

Figure 21: Removing the processor

Ê Release the socket lever and pull it upward as far as it will go.

Ê Carefully remove the installed processor .

2

1

Page 41: Tx300 s3 Options

RX300 S3 Options Guide 41

Processors Replacing the processor

Figure 22: Inserting a new processor

Ê Position the new processor over the socket and then carefully press it into the socket (1).

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners (2). To avoid damaging the pins or the processor, do not force it into the socket.

Ê Lock the processor in place in the socket by returning the socket lever to its original position (3).

Ê Remove the protective cover on the underside of the heat sink. Do not touch the pad.

Ê Place the heat sink on the processor socket (see figure 19 on page 37).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Ê Reinstall the air duct over the main memory and the processors (see “Inserting air duct” on page 31).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 42: Tx300 s3 Options

42 Options Guide RX300 S3

Replacing the processor heat sink Processors

6.3 Replacing the processor heat sink

Ê Open the server as described in section “Opening the server” on page 23.

Ê Remove the air duct over the main memory and the processors (see section “Upgrading/replacing the main memory” on page 28).

Ê Loosen the four heat sink screws in a crossover pattern (see section “Replacing the processor” on page 38).

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Ê Clean the upper side of the processor using a lint-free cloth.

Ê Remove the protective cover from the new heat sink.

Ê Place the heat sink on the processor socket (see section “Replacing the processor” on page 38).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Ê Reinstall the air duct over the main memory and the processors (see section “Upgrading/replacing the main memory” on page 28).

Page 43: Tx300 s3 Options

RX300 S3 Options Guide 43

7 ROMB (RAID on Motherboard)V CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

The on-board SAS controller can be upgraded to a RAID5 (RAID 0, 1, 5, 10, 50) controller with a "MegaRaid PCI Express™ ROMB" upgrade kit. In this case the on-board INTEL I/O processor is activated by installing a license key and a cache module.

Two different upgrade kits are offered:

– Upgrade kit S26361-F3205-E256, consisting of an iButton license key and a 256 MB cache module.

– Upgrade kit S26361-F3205-E556, consisting of an iButton license key and a 256 MB cache module with a battery also integrated on the module (iTBBU=integrated Transportable Battery Backup Unit).

7.1 Installing the ROMB upgrade kit

Ê Open the server as described in the chapter “Preparation” on page 21.

Page 44: Tx300 s3 Options

44 Options Guide RX300 S3

Installing the ROMB upgrade kit ROMB (RAID on Motherboard)

Figure 23: Cache module (with battery) and iButton

Ê Connect the cable on the module.

Figure 24: Installing the iButton and the Cache module

Ê Install the iButton on the system board (1).

1

Page 45: Tx300 s3 Options

RX300 S3 Options Guide 45

ROMB (RAID on Motherboard) Installing the ROMB upgrade kit

Ê Press the holders on either side of the mounting location outward.

Figure 25: iButton und Cache Modul einsetzen

Ê Insert the cache module.

Ê Press the cache module downward until the holders on either side of the mounting location are engaged.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

I Information on the configuration is provided in the Technical Manual for the system board.

Page 46: Tx300 s3 Options
Page 47: Tx300 s3 Options

RX300 S3 Options Guide 47

8 Accessible drivesV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

I Two free bays are available for accessible drives. One 3,5 Inch x 0,5 Inch is for a FD drive and one 5,25 inch x 0,5 inch is for a CD/DVD-ROM drive available. A local view module can also be installed Into the upper bay (FD drive).

V CAUTION!

For installing a FD drive or a CD-/DVD drive frames and cables are necessary.

Page 48: Tx300 s3 Options

48 Options Guide RX300 S3

Installing a FD drive Accessible drives

8.1 Installing a FD drive

Ê Open the server as described in the chapter “Preparation” on page 21.

Removing cover

Figure 26: Cover in front of fanbox

Ê Disengage the cover.

Ê Remove the cover.

Page 49: Tx300 s3 Options

RX300 S3 Options Guide 49

Accessible drives Installing a FD drive

Removing a FD drive dummy module

Figure 27: Unlocking the FD drive dummy module

Ê Unlock the FD drive dummy module (1).

Ê Push the FD drive dummy module to the front (2).

Figure 28: Removing dummy module

Ê Pull the FD drive dummy module out to the front side.

1

2

Page 50: Tx300 s3 Options

50 Options Guide RX300 S3

Installing a FD drive Accessible drives

V CAUTION!

Keep the dummy module for future use. If you remove the FD drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Installing FD drive

Figure 29: Insert FD drive into the mounting frame.

I The mouning frame and the cable is deliverd in the accessory pack with the PRIMERGY RX300 S2.

Ê Insert the FD drive into the mounting frame. Regard the plastic pins. They fix the dive in the frame.

Page 51: Tx300 s3 Options

RX300 S3 Options Guide 51

Accessible drives Installing a FD drive

Figure 30: connect the FDD-cable

Ê Connect the cable as shown in the photo.

I Install the cable so, that the blue side shows to the lockingmechanism of the connector of the drive.

Ê Thread the cable through the mounting frame.

Page 52: Tx300 s3 Options

52 Options Guide RX300 S3

Installing a FD drive Accessible drives

Figure 31: Inserting FD drive module

Ê Thread the flat cable in the bay.

Ê Push the FD drive module into the bay, until it locks.

Figure 32: Connecting FD drive cable

Ê Connect the FDD cable to the system board.

Ê Reinstall the cover again.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 53: Tx300 s3 Options

RX300 S3 Options Guide 53

Accessible drives Installing a LocalView module

8.2 Installing a LocalView module

The LocalView module is an optional extra for the servers of the PRIMERGY series. On the display panel of the LocalView module you can read status messages directly on the server. These status messages provide information on the system and notify you of hardware faults (e.g. fan failure, CPU over voltage, etc.).

The LocalView module can be pulled out like a sliding drawer. You can also angle the LocalView display panel downward.

The LocalView module can be installed in the 3,5/0,5 inch bay of the FD drive.

Figure 33: LocalView module

Ê Open the server as described in the chapter “Preparation” on page 21.

Ê remove the cover (see “Removing cover” on page 48)

Ê If a FDD-dummy module is installed it must be removed (see “Removing a FD drive dummy module” on page 49).

Page 54: Tx300 s3 Options

54 Options Guide RX300 S3

Installing a LocalView module Accessible drives

Removing the FD Drive

Figure 34: Unlocking the the FD Drive module (for better visibility, the fanbox is removed)

Ê Unlock (1) the FDD module.

Ê Push the FDD module to the front (2).

Ê Remove the FD drive cable from the system board.

Figure 35: Removing FD-Drive module

Ê Pull the FD drive module out. to the front side.

1

2

Page 55: Tx300 s3 Options

RX300 S3 Options Guide 55

Accessible drives Installing a LocalView module

Figure 36: Cable out of cable clamp

Ê Take out the cable for the LocalView module from the cable clamp and thread the cable through the bay to the front side.

Figure 37: Connecting the cable to the LocalView module

Ê Connect the cable to the LocalView module.

Page 56: Tx300 s3 Options

56 Options Guide RX300 S3

Installing a LocalView module Accessible drives

Figure 38: Inserting the LocalView module

Ê Slide the LocalView module into the mounting location until it latches in place.

I Further information on operation and display modes is provided in the documentation for the LocalView module.

Ê Reinstall the cover again.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 57: Tx300 s3 Options

RX300 S3 Options Guide 57

Accessible drives Installing the CD/ DVD-ROM drive

8.3 Installing the CD/ DVD-ROM drive

Ê Open the server as described in the chapter “Preparation” on page 21.

Ê Remove the cover (see “Removing cover” on page 48)

Removing the CD/DVD drive dummy module

Figure 39: Unlocking the CD drive dummy module

Ê Unlock (1) the CD/DVD drive dummy module.

Ê Push the CD/DVD module to the front (2) out by the retention mechanism and take out the CD/DVD module frontward (3).

1

3

2

Page 58: Tx300 s3 Options

58 Options Guide RX300 S3

Installing the CD/ DVD-ROM drive Accessible drives

Figure 40: Removing dummy module with mounting frame

Ê Remove the dummy module.

V CAUTION!

Keep the dummy module for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Ê Remove the dummy module from the mounting frame

Page 59: Tx300 s3 Options

RX300 S3 Options Guide 59

Accessible drives Installing the CD/ DVD-ROM drive

Figure 41: Installing CD/ DVD Laufwerk in the mounting frame

Ê Install the CD/DVD Drive in the mounting frame Regard the plastic pins which fix the drive in the frame.

Figure 42: Connecting the CD/DVD drive cables

Ê Thread the power cable (1) through the bay and connect it to the CD Drive (see also chapter “Appendix” on page 105).

Page 60: Tx300 s3 Options

60 Options Guide RX300 S3

Tape drive Accessible drives

Ê Connect the IDE cable to the drive (see also chapter “Appendix” on page 105)

Figure 43: Pushing the CD/DVD drive into the bay

Ê Push the drive into the bay completely.

Ê Reinstall the cover again.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

8.4 Tape drive

I The Installtion of a tape drive ist only possible for the 3,5“ HDD version.

Ê Open the server as described in the chapter “Preparation” on page 21.

Ê Remove the cover (see “Removing cover” on page 48).

Page 61: Tx300 s3 Options

RX300 S3 Options Guide 61

Accessible drives Tape drive

Figure 44: Push USB tapedrive into the mounting carrier

Ê Push the tape drive into the mounting carrier.

Ê Insert the screws on the right and left side.

Figure 45: Installing the USB tape drive

Ê Thread the USB cable and the power cable through the duct to the front.

Page 62: Tx300 s3 Options

62 Options Guide RX300 S3

Tape drive Accessible drives

Figure 46: rear side of the tape drive

Ê Connect the USB cable (1) to the rear side of the tape drive

Ê Connect the power cable (2) to the rear side of the tape drive

Figure 47: USB Magnetbandlaufwerk einbauen

Ê Push the tape drive in.

1 2

Page 63: Tx300 s3 Options

RX300 S3 Options Guide 63

Accessible drives Tape drive

Ê When pushing the drive into place pull the cables back so that they are not pinched

Ê Lock the drive.

I The front of the drive projects approx. 5mm beyond the front of the server.

Figure 48: Connecting USB cable to the system board

Ê Connect the power cableto the SAS backplane

Ê Connect the USB Cable to the USB7 connector on the system board.

Ê Insert the cover.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 64: Tx300 s3 Options
Page 65: Tx300 s3 Options

RX300 S3 Options Guide 65

9 PCI slotsV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

Standard configuration

The system board offers five PCI slots. Slots 1, 2 and 5 are non-hot-plug PCI slots .

I The PCI slot 3 and 4 are hot-plug slots, that can be equipped with hot-plug controllers. You will find the description of the hot-plug slots in the Operating Manual.

Optional configuration with riser card

Three standard slots are available with a riser card: 1 x PCI-X 64-bit/100 MHz, long, standard height; 2 x PCI-X 64-bit/100 MHz, short, standard height.

Page 66: Tx300 s3 Options

66 Options Guide RX300 S3

Installing a PCI controller in a low-profile slot PCI slots

9.1 Installing a PCI controller in a low-profile slot

Ê Open the server as described in the chapter “Preparation” on page 21.

Figure 49: Remove the slot cover

Ê Push the green PCI board holder toward the rear (1).

Ê Remove the slot cover of the PCI slot (2).

V CAUTION!

Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

1 2

Page 67: Tx300 s3 Options

RX300 S3 Options Guide 67

PCI slots Installing a PCI controller in a low-profile slot

Figure 50: Inserting controller

Ê Install the controller in the PCI slot and press it carefully into the associated plug-in location on the system board (1). Ensure that the rear cover fits into the recesses (a).

Ê Close the green PCI board holder (2).

Ê If required, connect the cables to the controller and other components.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

a

a

1

2

Page 68: Tx300 s3 Options

68 Options Guide RX300 S3

Installing the PCI controller in the riser card PCI slots

9.2 Installing the PCI controller in the riser card

Ê Open the server as described in the chapter “Preparation” on page 21.

Figure 51: Removing the riser card

Ê Open the knurled screws.

V CAUTION!

Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 69: Tx300 s3 Options

RX300 S3 Options Guide 69

PCI slots Installing the PCI controller in the riser card

Figure 52: Removing the riser card

Ê Remove the riser card upward.

I Hold the riser by the latch (A).

A

Page 70: Tx300 s3 Options

70 Options Guide RX300 S3

Installing the PCI controller in the riser card PCI slots

Figure 53: Installing the controller

Ê Press on the locking mechanism of the cover.

Ê Open the locking mechanism.

Page 71: Tx300 s3 Options

RX300 S3 Options Guide 71

PCI slots Installing the PCI controller in the riser card

Figure 54: Installing controller

Ê Remove the slot cover of the requested slot.

Page 72: Tx300 s3 Options

72 Options Guide RX300 S3

Installing the PCI controller in the riser card PCI slots

Figure 55: Installing Controller

Ê Insert the controller into the PCI slot and push it down carefully.

Ê Close the cover.

Page 73: Tx300 s3 Options

RX300 S3 Options Guide 73

PCI slots Installing the PCI controller in the riser card

Figure 56: Installed Controller

Ê If necessary connect the cables to the controller or other components.

Ê Insert the riser card and be careful with the cables.

I Take care that the latch is engaged in the side panel.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 74: Tx300 s3 Options
Page 75: Tx300 s3 Options

RX300 S3 Options Guide 75

10 External serial interfaceV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

10.1 Installing the external serial interface

Ê Open the server as described in the chapter “Preparation” on page 21.

I For standard configuration the external serial interface is to install with a low profile slot cover. If the optional riser card is used, a standard slot cover is necessary.

External serial interface in standard configuration

Figure 57: External serial cable with low-profile slot cover.

Ê Remove slot cover 5 ( see “Remove the slot cover” on page 66)

Page 76: Tx300 s3 Options

76 Options Guide RX300 S3

Installing the external serial interface External serial interface

Figure 58: Installing external serial cable

Ê Insert the slot cover.

Ê Lock the the slot cover.

Ê Route the serial cable, as shown in the picture.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 77: Tx300 s3 Options

RX300 S3 Options Guide 77

External serial interface Installing the external serial interface

External SCSI interface in the riser

Figure 59: External serial interface with standart slot

Ê Insert the SCSI connector to the slot cover.

Figure 60: Remove riser

Ê Remove the riser.

Page 78: Tx300 s3 Options

78 Options Guide RX300 S3

Installing the external serial interface External serial interface

Figure 61: Removing slot cover from slot 6

Ê Open the cover.

Ê Remove the slot cover of slot 8.

Page 79: Tx300 s3 Options

RX300 S3 Options Guide 79

External serial interface Installing the external serial interface

Figure 62: External serial interface

Ê Insert the slot cover with the serial interface in slot 8.

Ê Close the cover.

Page 80: Tx300 s3 Options

80 Options Guide RX300 S3

Installing the external serial interface External serial interface

Figure 63: Thread external cable

Ê Thread the cable through the cutout.

Figure 64: Inserting the riser

Ê Insert the riser.

Page 81: Tx300 s3 Options

RX300 S3 Options Guide 81

External serial interface Installing the external serial interface

Ê Connect the external serial cable to the system board (see arrow).

Ê Fix the riser with the two screws.

Figure 65: Connecting the external SCSI cable to the system board

Ê Route the cable as shown.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

I If another external parallel interface is to be installed in addition to the external serial interface, route the cables as shown in the next step.

The serial interface is then installed in slot 7 and the parallel interface in slot 8.

Page 82: Tx300 s3 Options

82 Options Guide RX300 S3

Installing the external serial interface External serial interface

Figure 66: External serial and parallel interface

Ê Route the both cables as shown in the picture.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 83: Tx300 s3 Options

RX300 S3 Options Guide 83

11 Parallel interfaceV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

11.1 Installing a parallel interface

Ê Open the server as described in the chapter “Preparation” on page 21.

I For standard configuration the parallel interface is to install into a low-profile slot cover. If the optional riser board is used, a standard slot cover is necessary.

Parallel interface in standard configuration

Figure 67: external parallel interface with low-profile slot cover

Ê Remove slot cover 5 ( see “Remove the slot cover” on page 66)

Page 84: Tx300 s3 Options

84 Options Guide RX300 S3

Installing a parallel interface Parallel interface

Figure 68: Routing the cable

Ê Insert the slot cover with the parallel interface.

Ê Connect the cable to the system board (see arrow).

Ê Route the cable as shown in the picture directly upon the system board.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 85: Tx300 s3 Options

RX300 S3 Options Guide 85

Parallel interface Installing a parallel interface

External Parallel-interface in slot cover with standard height

Figure 69: External parallel interface with standard slot cover

Ê Insert the connector of the parallel interface in the slot cover.

Figure 70: Removing the riser

Ê Remove the riser.

Page 86: Tx300 s3 Options

86 Options Guide RX300 S3

Installing a parallel interface Parallel interface

Figure 71: Removing the slot cover of slot 8

Ê Remove the slot cover of slot 8.

Page 87: Tx300 s3 Options

RX300 S3 Options Guide 87

Parallel interface Installing a parallel interface

Figure 72: Instelling the slot cover with the connector of ther parallel interface

Ê Insert the slot cover with the parallel interface in slot 8.

Page 88: Tx300 s3 Options

88 Options Guide RX300 S3

Installing a parallel interface Parallel interface

Figure 73: Install the slot cover with a parallel interface

Ê Thread the flat cable between the riser board and the plastic side cover.

I Route the cable as shown in the photo.

Page 89: Tx300 s3 Options

RX300 S3 Options Guide 89

Parallel interface Installing a parallel interface

Figure 74: Installing the riser with parallel interface.

Ê Insert the riser.

Ê Route the cable.

Ê Connect the cable to the system board.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 90: Tx300 s3 Options
Page 91: Tx300 s3 Options

RX300 S3 Options Guide 91

12 Converting from low-profile to standard PCI Slots

V CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

12.1 Removing lp slot cage

Ê Open the server as described in the chapter “Preparation” on page 21.

Figure 75: Removing hot-plug cable

Ê Release and remove the hot-plug cable from the system board.

Page 92: Tx300 s3 Options

92 Options Guide RX300 S3

Removing lp slot cage Converting from low-profile to standard PCI Slots

Figure 76: Removing the slot cage

Ê Remove the two screws.

Ê Pull the slot cage out.

Figure 77: Without slot cage

Ê Equip the riser card as described in part “Installing the PCI controller in the riser card” on page 68.

Page 93: Tx300 s3 Options

RX300 S3 Options Guide 93

Converting from low-profile to standard PCI Slots Removing lp slot cage

Figure 78: Assembled Riser card

Page 94: Tx300 s3 Options

94 Options Guide RX300 S3

Converting the air duct Converting from low-profile to standard PCI Slots

12.2 Converting the air duct

Figure 79: Removing cover

Ê Push the cover up.

Page 95: Tx300 s3 Options

RX300 S3 Options Guide 95

Converting from low-profile to standard PCI Slots Converting the air duct

Figure 80: Cover removed

Figure 81: Installing cover

Page 96: Tx300 s3 Options

96 Options Guide RX300 S3

Converting the air duct Converting from low-profile to standard PCI Slots

Ê Push the cover int the guides on the uppper side of the air duct.

Figure 82: converted air duct for riser

Page 97: Tx300 s3 Options

RX300 S3 Options Guide 97

Converting from low-profile to standard PCI Slots Converting the air duct

Figure 83: Installing the air duct

Ê Insert the air duct.

I When you install the air duct take care of teh heat sink fins and the condenser in the marked area.

Page 98: Tx300 s3 Options

98 Options Guide RX300 S3

Installing the riser Converting from low-profile to standard PCI Slots

12.3 Installing the riser

Figure 84: Inserting the riser

Ê Install the riser.

Page 99: Tx300 s3 Options

RX300 S3 Options Guide 99

Converting from low-profile to standard PCI Slots Installing the riser

Figure 85: With riser

Ê Press the riser firmly in place.

I Take care that the latch is engaged in the side panel.

Ê Tighten the two screws.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 101.

Page 100: Tx300 s3 Options
Page 101: Tx300 s3 Options

RX300 S3 Options Guide 101

13 CompletionV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15.

13.1 Closing the server

Figure 86: Closing the cover

Ê Apply the cover.

Ê Push the cover to the front (1).

Ê Make sure that the locks engage.

Page 102: Tx300 s3 Options

102 Options Guide RX300 S3

Closing the server Completion

If you have not removed the server from the rack cabinet, please skip this page.

Figure 87: Installing the server in a rack cabinet

V CAUTION!

At least two people are required to install the server in the rack cabinet.

Do not use the handles on the rack front cover to lift the server into the rack.

Ê Lower the server from above onto the extended telescopic rails.

Ê Push the server in the direction of the arrow (1) until the hooks of the telescopic rails engage.

Ê Release the telescopic rails’ locking mechanism (2) on both sides and push the server as far as it will go into the rack.

Ê Reconnect all the cables you disconnected beforehand on the rear of the server.

Page 103: Tx300 s3 Options

RX300 S3 Options Guide 103

Completion Closing the server

Figure 88: Fastening the knurled screws

Ê Fasten the server in the rack using the two knurled screws (1).

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

Page 104: Tx300 s3 Options
Page 105: Tx300 s3 Options

RX300 S3 Options Guide 105

14 Appendix

14.1 Cabling

The following table gives you an overview of the cables:

*refers to the drawings of the cabling

Cable # *

Part number Item number Designation Length/mm

1 S26361-F3120-V2 Parallel port 310

2 T26139-Y3694-V103 A3C40071653 PS 20 pol 280

3 T26139-Y3758-V7 A3C40057188 PS 24 pol 250

4 T26139-Y3939-V101 A3C40068169 PS SAS backplane /CDD

700

4b T26139-Y3939-V111 A3C40085560 PS Expander-Board- CDD

1200

5 T26139-Y3925-V201 A3C40068188 Front panel 250

6 T26139-Y3662-V303 A3C40057187 ULTRA ATA 100

7 T26139-Y3696-V12 A3C40057186 FDD 150

8 T26139-Y3718-V105 A3C40039940 SMB 650

9 S26361-F3120-V3 Serial port 300

10 T26139-Y3906-V7 A3C40057182 Hot-plug 120

11 A3C40083827 USB 400

12 T26139-Y3959-V201 A3C40074671 SV tape drive 270

Page 106: Tx300 s3 Options

106 Options Guide RX300 S3

Cabling Appendix

Figure 89: Verkabelung RX300 S3 mit 3,5“ Festplattenlaufwerken

Loca

lV

iew

Power

Legend:

IDT

EM

PC

omb o

CD

DS

limlin

e

FD

DS

limlin

e

US

B

SMBus

IDE/FDDSignal

Pow

erS

upply

Pow

erS

upply

optionalParallel Porthot plug

Data

optionalSerial Port

US

B7

USB

Tape

USB

11

X13

X12

12

Cabling RX300 S3 with 6 x 3,5” HDD

4a

a

Page 107: Tx300 s3 Options

RX300 S3 Options Guide 107

Appendix Cabling

Figure 90: Verkabelung RX300S3 mit 2,5“ Festplattenlaufwerke

Loca

lV

iew

Power

Legend:

IDT

EM

PC

ombo

CD

DS

limlin

e

FD

DS

limlin

e

US

B

SMBus

IDE/FDDSignal

Pow

erS

upply

Pow

erS

upply

optionalParallel Porthot plug

Data

optionalSerial Port

US

B7

USB

X4

HD

DID

1

HD

DID

2

HD

DID

3

HD

DID

5

HD

DID

6

HD

DID

4

HD

DID

7

HD

DID

8

HD

DID

9

HD

DID

11

HD

DID

12

HD

DID

10

X6X7

Cabling RX300 S3 with12 x 2,5” HDD

4b

4b

al

Page 108: Tx300 s3 Options

108 Options Guide RX300 S3

Configuration diagram Appendix

14.2 Configuration diagram

14.2.1 Configuration with 3.5“ HDDs

Figure 91: Part of the system configurator 3.5“ HDD

board front sidemiddle

Channel 0 (2 Modules) Bay for LocalView LCDXeon DP or 3.5"x 0,5" Floppy disk

Channel I (2 Modules)

Channel II (2 Modules) Air channelXeon DP

Channel III (2 Modules) Bay for 5,25"x 0,5" IDE-CD

or DVD-ROM Memory ( III ) Processor ( II )

Accessible drives ( V )rear side

Fan 1 - Fan 4 1. PSU 2. PSU Needs space for 2

hard disk drives!Fan 5 - Fan 8 3.5"x1,6"

Redundant system- Redundant power fans option Backup drive option supply option

Hard disk drives ( VI ) RAID 5 support Licence key + 256MB Cache left side

onboard Licence key + 256MB Cache+BBU

Extension slots for 3.5"x1" SAS or SATA

SCSI Controller ( VII )Disk Array ( VIII )Communication/Network ( IX ) 3.5"x1" SAS or SATA Miscellaneous ( X )

RISER optionSlot 5: PCIe x8, Low Profile 3.5"x1" SAS or SATA

Slot 6: Slot 7: Slot 8:

HOT PLUGSlot 4: PCIe x4, Low Profile (mech. x8)

right side

PCI-X 64 PCI-X 64 PCI-X 64

HOT PLUGSlot 3: PCIe x4, Low Profile (mech. x8) 3.5"x1" SAS or SATA

133 MHz 133 MHz 133 MHz

Slot 2: PCI-X 64-Bit / 133MHz, Low Profile 3.5"x1" SAS or SATA

Standard Standard Standard

Slot 1: PCI-X 64-Bit / 133MHz, Low Profile 3.5"x1" SAS or SATA

short short long

All

low

pro

file

slot

s ar

e co

vere

d, if

PC

I-ris

er c

ard

conf

igur

ed

Page 109: Tx300 s3 Options

RX300 S3 Options Guide 109

Appendix Configuration diagram

14.2.2 Configuration with 2.5“ HDDs

Figure 92: part of the system configurator 2.5“ HDD

Page 110: Tx300 s3 Options

110 Options Guide RX300 S3

Hard disk mirroring Appendix

14.3 Hard disk mirroring

Figure 93: part of the system configurator

On-board SAS-Controller for SAS-HDs and SATA HD`s

The system is equipped with a eight channel SAS on-board controller and embedded "IME".IME (Integrated Mirroring Enhanced) offers the RAID levels 0, 1, 1E w ithout any additional costs.IME is a RAID 0, 1 implementation, w hereby RAID 1 can operate w ith an odd number of hard disks.Up to 6 hard disks including one hot spare HD are possible (limited by HHD slots in system). Administration of IME is possible w ith the LSI Global Array Manager (GAM). Window s2000/2003 as w ell as SUSE and RedHat Linux are supported (Restrictions refer to Softw are Configurator)The SAS IME solution supports 2 independent RAID volumes, one can contain SAS disks the other SATA disks.No additional components required. 1x per RX300 S3

Example with 3 HD`s:

The on-board SAS-controller can be upgraded via the "MegaRaid PCI Express™ ROMB" upgrade kit to a fullSAS RAID controller (RAID 0, 1, 5, 10, 50 ). The onbaord SAS controller supports the follow ing configuration only:Six internal SAS or SATA II HD`s in the basic unit, but no optional tape! no support for external tapes (e.g. SX10) no support for external discs (e.g. SX30) 1x per RX300 S3

Page 111: Tx300 s3 Options

RX300 S3 Options Guide 111

AbbreviationsAC

Alternating Current

ANSIAmerican National Standard Institut

ASR&RAutomatic Server Reconfiguration and Restart

BIOSBasic Input-Output System

BMCBaseboard Management Controller

CCCache Coherency

CDCompact Disk

CD-ROMCompact Disk-Read Only Memory

CHSCylinder Head Sector

CMOSComplementary Metal Oxide Semiconductor

COMCommunication

CPUCentral Processing Unit

DCDirect Current

Page 112: Tx300 s3 Options

112 Options Guide RX300 S3

Abbreviations

DIMMDual Inline Memory Module

DIPDual Inline Package

DMADirect Memory Access

DMIDesktop Management Interface

ECCErrror Checking and Correcting

ECPExtended Capabilities Port

EEPROMElectrically Erasable Programmable Read-Only Memory

EMCElectroMagnetic Compatibility)

EMPEmergency Management Port

EPPEnhanced Parallel Port

ESDElectroStatic Discharge

FPCFront Panel Controller

FRUField Replaceable Unit

FSB

Page 113: Tx300 s3 Options

RX300 S3 Options Guide 113

Abbreviations

Front Side Bus

GAMGlobal Array Manager

GUIGraphical User Interface

HDDHard Disk Drive

HSCHot-Swap Controller

I²CInter-Integrated Circuit

I/OInput/Output

ICMIntelligent Chassis Management

IDIdentification

IDEIntergrated Drive Electronics

IOOPIntetelligent Organization of PCI

IRQInterrupt Request Line

LANLocal Area Network

LBALogical Block Address

LCD

Page 114: Tx300 s3 Options

114 Options Guide RX300 S3

Abbreviations

Liquid Crystal Display

LUNLogical Unit Number

LVDLow-Voltage Differential SCSI

MMFMulti Mode Faser

MRLManually Retention Latch

NMINon Maskable Interrupt

NVRAMNon Volatile Random Access Memory

OSOperating System

PCIPeripheral Component Interconnect

PDAPrefailure Detection and Analysing

POSTPower ON Self Test

RAIDRedundant Arrays of Independent Disks

RAMRandom Access Memory

ROMRead-Only Memory

RSB

Page 115: Tx300 s3 Options

RX300 S3 Options Guide 115

Abbreviations

Remote Service Board

RTCReal Time Clock

RTDSRemote Test- und Diagnose-System

SAF-TESCSI Accessed Fault-Tolerance Enclosures

SBESingle Bit Error

SCASingle Connector Attachment

SCSISmall Computer System Interface

SDDCSingle Device Data Correction

SDRSensor Data Record

SDRAMSynchronous Dynamic Random Access Memory

SELSystem Event Log

SMISystem Management Interrupt

SSUSystem Setup Utility

SVGASuper Video Graphics Adapter

USB

Page 116: Tx300 s3 Options

116 Options Guide RX300 S3

Abbreviations

Universal Serial Bus

VGAVideo Graphics Adapter

Page 117: Tx300 s3 Options

RX300 S3 Options Guide 117

Related publicationsPRIMERGY manuals are available as PDF file on the ServerBooks CD. The ServerBooks CD is part of the PRIMERGY ServerView Suite delivered with each server system.

The current versions of the required manuals can be downloaded free of charge as PDF files from the Internet. The overview page showing the online documen-tation available on the Internet can be found via the URL:http://manuals.fujitsu-siemens.com. For the documentation of the PRIMERGY servers choose the navigation point industry standard servers.

[1] Safety notes and other important information

[2] Ergonomics

[3] Warranty

[4] Returning used devices

[5] PRIMERGY RX300 S3 Operating Manual

[6] Quick Start Hardware - PRIMERGY z.B. RX300 Leaflet

[7] Quick Start Software - PRIMERGY ServerView Suite Leaflet

[8] System Board D2119 Technical Manual

[9] PRIMECENTER Rack Technical Manual

[10] DataCenter Rack Technical Manual

[11] 19 inch rack Technical Manual

[12] LocalView User Manual

Page 118: Tx300 s3 Options

118 Options Guide RX300 S3

Related Publications

[13] Secure PRIMERGY Server Management Enterprise SecurityPRIMERGY server management for secure, highly available platformsWhite Paper

[14] PRIMERGY ServerView Suite ServerStartUser Guide

[15] PRIMERGY ServerView Suite RemoteDeployUser Guide

[16] PRIMERGY ServerView Suite ServerView InstallationUser Guide

[17] PRIMERGY ServerView Suite ServerView S2Server ManagementUser Guide

[18] PRIMERGY ServerView Suite Local View User Guide

Page 119: Tx300 s3 Options

RX300 S3 Options Guide 119

Related Publications

[19] PRIMERGY ServerView Suite ServerView S2 Online DiagnosticsUser Guide

[20] PRIMERGY ServerView Suite Inventory ManagerServerViewUser Guide

[21] PRIMERGY ServerView Suite Asset Management Command Line InterfaceUser Guide

[22] PRIMERGY ServerView Suite Archive ManagerServerViewUser Guide

[23] PRIMERGY ServerView Suite AlarmServiceServerViewUser Guide

[24] PRIMERGY ServerView Suite Performance ManagerUser Guide

[25] PRIMERGY ServerView Suite Download ManagerServerViewUser Guide

[26] PRIMERGY ServerView Suite ServerView RAID ManagerUser Guide

[27] PRIMERGY ServerView Suite GlobalFlash ToolServerViewUser Guide

Page 120: Tx300 s3 Options

120 Options Guide RX300 S3

Related Publications

[28] PRIMERGY ServerView Suite PrimeUp User Guide

[29] PRIMERGY ServerView Suite Bootable Update CDUser Guide

[30] PRIMERGY ServerView Suite ServerView IntegrationOverview

[31] PRIMERGY ServerView Suite ServerView Integration in Microsoft SMSUser Guide

[32] PRIMERGY ServerView Suite ServerView Integration in Microsoft Operations ManagerUser Guide

[33] PRIMERGY ServerView Suite ServerView Integration in CA UnicenterUser Guide

[34] PRIMERGY ServerView Suite ServerView Integration in Novell Remote ManagerUser Guide

[35] PRIMERGY ServerView Suite ServerView Integration in HP OV NNMUser Guide

[36] PRIMERGY ServerView Suite ServerView Integration in HP OV OperationsUser Guide

[37] PRIMERGY ServerView Suite ServerView Integration in Tivoli NetViewUser Guide

[38] PRIMERGY ServerView Suite ServerView Integration in Tivoli/TECUser Guide

Page 121: Tx300 s3 Options

RX300 S3 Options Guide 121

Related Publications

[39] PRIMERGY ServerView Suite ServerView Integration in DeskViewUser Guide

[40] PRIMERGY ServerView Suite RemoteViewUser Guide

[41] PRIMERGY ServerView Suite integrated Remote Management Controller (iRMC)User Guide

[42] Baseboard Management Controller (BMC) Configuration for PRIMERGY SystemsUser Guide

[43] RemoteView Service Board Installation Guide

[44] RemoteView Service Board S2 User Guide

[45] RemoteView Service Board S2 Installation Guide

[46] PRIMERGY BX300 Blade Server System Operating Manual

[47] PRIMERGY BX600 Blade Server System Operating Manual

[48] PRIMERGY Blade Server System RemoteView Management BladeUser Interface DescriptionUser Guide

[49] PRIMERGY Blade Server System LAN Switch BladeUser Interface DescriptionUser Guide

[50] BIOS-Setup Description

Page 122: Tx300 s3 Options

122 Options Guide RX300 S3

Related Publications

[51] PRIMEPOWER ServerView Suite System Administration within a DomainUser Guide

[52] DuplexDataManager® für Windows NT DuplexWriteProduct Manual

[53] DuplexDataManager® for Windows NT MultiPathProduct Manual

[54] DuplexDataManager® for LINUX DuplexWriteProduct Manual

[55] APC network management card User’s Guide

[56] VMware ESX Server Installation Guide

[57] VMware ESX Server Administration Guide

Page 123: Tx300 s3 Options

RX300 S3 Options Guide 123

IndexAaccessible drives 10, 47air duct 28

Ccomponents

hardware/software 7Controller 11, 66, 68converting form low profile to standard

slots 91

Ddata manipulation 7dual operation 33, 38

EESD (electrostatic sensitive

device) 20external SCSI interface 12, 75external serial interface 12

HHard disk drives 11heat sink 42hot-plug

PCI slot 7tape drive 10

IiButton 44information

additional 8information material 8

Llight-emitting diode (LED) 19Lithium battery 18LocalView module 11, 53

Mmain memory 10, 25meaning of the symbols 12

multiprocessor operating system 33, 38

Nnotational conventions 12note about the laser 19

Pparallel interface 12, 83PCI slot

hot-plug 7processor 33processor heat sink 42

RROMB 10

Ssecurity functions 7slot cover 75

Ttape drive

hot-plug 10target group 7

Page 124: Tx300 s3 Options

124 Options Guide RX300 S3

Index