Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

Embed Size (px)

Citation preview

Page 1: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

Two Minute Drill Number 26- ResidentialImproving your skill in code Look Up Increasing Speed Drill

Copyright 2008 Ted "Smitty" Smith

Page 2: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

Directions Left click on the presentation ICON located at the bottom of

the slide directory to the left of the this slide. Each slide will transition to the correct answer automatically in

2:00 minutes. The correct answer will transition in 15 seconds. As you progress through the slide show, the time for each question will be reduced.

Write down the correct answer to each question and the code reference as it is displayed so you can review them later.

This presentation is mostly concerning Residential. We have included a few other categories just to help keep you sharp.

Copyright 2008 Ted "Smitty" Smith

Page 3: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

1. A listed instantaneous water heater shall be permitted to be subdivided into circuits protected at NOT more than _____.

a. 60 amperesb. 100 amperesc. 120 amperesd. 150 amperes

Copyright 2008 Ted "Smitty" Smith

Page 4: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

1. d 422.11(F)(3)

Copyright 2008 Ted "Smitty" Smith

Page 5: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

2. The interior of enclosures or raceways installed underground shall be considered to be a ______.

a. Wet location

b. Damp location

c. Moist location

d. Dry location

Copyright 2008 Ted "Smitty" Smith

Page 6: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

2. a 300.5(B)

Copyright 2008 Ted "Smitty" Smith

Page 7: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

3. The continuity of the grounding conductor system for portable electrical carnival equipment shall be verified _____.

a. And recorded on an annual basis

b. And recorded on a quarterly basis

c. And recorded on a monthly basis

d. Each time the equipment is connected

Copyright 2008 Ted "Smitty" Smith

Page 8: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

3. d 525.32

Copyright 2008 Ted "Smitty" Smith

Page 9: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

4. A plate type grounding electrode shall be installed below the surface of the earth NOT less than _____.

a. 24 inches

b. 30 inches

c. 36 inches

d. 48 inches

Copyright 2008 Ted "Smitty" Smith

Page 10: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

4. b 250.53(H)

Copyright 2008 Ted "Smitty" Smith

Page 11: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

5. Determine the MAXIMUM allowable ampacity of a size 1/0 AWG THW copper current-carrying conductor installed in a common raceway with three other current-carrying conductors of the same size. Ambient temperature is 86ºF.

a. 150 amperes

b. 105 amperes

c. 112 amperes

d. 120 amperes

Copyright 2008 Ted "Smitty" Smith

Page 12: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

5. d Tbl. 310.16 Tbl. 310.15(B)(2)(a)

Size 1/0 AWG THW ampacity(before de-rating) = 150 amperes

150 amperes X 80% (adjustment factor)

= 120 amperes Copyright 2008 Ted "Smitty"

Smith

Page 13: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

6. The NEC® defines a continuous-load to be a load where the maximum current on the circuit is expected to continue for at least _____ hours or more.

a. 3

b. 4

c. 6

d. 8

Copyright 2008 Ted "Smitty" Smith

Page 14: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

6. a Art. 100

Copyright 2008 Ted "Smitty" Smith

Page 15: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

7. Determine the MINIMUM size THW copper branch-circuit conductors required by the NEC® to supply a three-phase, continuous duty, AC motor that has a full-load current of 70 amperes. Assume all terminations to be rated at 75ºC.

a. 1 AWG

b. 2 AWG

c. 3 AWG

d. 4AWG

Copyright 2008 Ted "Smitty" Smith

Page 16: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

7. c 430.22(A) Tbl. 310.16 FLC of motor – 70 amperes X 125% = 87.5

amperes Size AWG THW conductors with an

ampacity of 100 amperes should be selected.

Copyright 2008 Ted "Smitty" Smith

Page 17: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

8. Given: you have determined a conductor has a computed allowable ampacity of 75 amperes. What is the MAXIMUM standard ampere rating of the overcurrent protection device the NEC® permits to protect this circuit? This is not a motor circuit or part of a multi-outlet branch-circuit supplying receptacles.

a. 70 amperes

b. 75 amperes

c. 80 amperes

d. 85 amperes

Copyright 2008 Ted "Smitty" Smith

Page 18: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

8. c 240.4(B)(2)&(3) 240.6(A)

Copyright 2008 Ted "Smitty" Smith

Page 19: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

9. A 208-volt, three-phase, 50HP, squirrel-cage, continuous duty, Design C, AC motor has a full-load running current of ______.

a. 130 amperes

b. 143 amperes

c. 162 amperes

d. 195 amperes

Copyright 2008 Ted "Smitty" Smith

Page 20: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

9. b Tbl. 430.250

Copyright 2008 Ted "Smitty" Smith

Page 21: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

10. Which of the following metal piping systems contained in a building is/are required to be bonded?

a. A gas pipe for a gas heaterb. A bathroom copper water pipe, connected

to an electric water heater.c. An air line for compressed aird. All these need to be bonded.

Copyright 2008 Ted "Smitty" Smith

Page 22: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

10. d250.104(B)

Copyright 2008 Ted "Smitty" Smith

Page 23: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

11. Determine the MINIMUM trade size electrical metallic tubing (EMT) required to enclose eight size 6 AWG copper conductors with THHW insulation, installed in a 60 foot conduit run.

a. 1 inch

b. 1 ¼ inch

c. 1 ½ inch

d. 2 inch

Copyright 2008 Ted "Smitty" Smith

Page 24: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

11. bAnnex C, Tbl. C. 1

Copyright 2008 Ted "Smitty" Smith

Page 25: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

12. When a feeder supplies a continuous-load of 240 amperes, in general, the overcurrent protection device protecting this circuit shall have a MINIMUM rating of _____.

a. 240 amperes

b. 300 amperes

c. 250 amperes

d. 275 amperes

Copyright 2008 Ted "Smitty" Smith

Page 26: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

12. b215.3 240 amperes X 125% = 300

amperes

Copyright 2008 Ted "Smitty" Smith

Page 27: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

13. In general, liquid-tight flexible metal conduit (LFMC) shall be securely fastened within _____ of each box or other conduit termination.

a. 4 ½ feet

b. 3 feet

c. 12 inches

d. 18 inches

Copyright 2008 Ted "Smitty" Smith

Page 28: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

13. c350.30(A)

Copyright 2008 Ted "Smitty" Smith

Page 29: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

14. When a pull box contains conductors of size 4 AWG and larger and a straight pull of the conductors is to be made, the length of the box shall NOT be less than _____ times the trade diameter of the largest conduit entering the box.

a. Six

b. Four

c. Eight

d. Twelve

Copyright 2008 Ted "Smitty" Smith

Page 30: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

14. c314.28(A)(1)

Copyright 2008 Ted "Smitty" Smith

Page 31: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

15. In general, all of the following wiring methods listed are permitted to be used as a feeder for temporary wiring on a construction site EXCEPT _____.

a. NM cable

b. NMC Cable

c. Type PD cord

d. Type SJO cord

Copyright 2008 Ted "Smitty" Smith

Page 32: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

15. c590.4(B) Tbl. 400.4

Copyright 2008 Ted "Smitty" Smith

Page 33: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

16. Determine the MAXIMUM number of size 14 AWG THHN conductors permitted to be installed in a trade size 3/8 inch flexible metal conduit (FMC) that contains a bare size 14 AWG grounding conductor when the flex has external fittings.

a. Two

b. Three

c. Four

d. five

Copyright 2008 Ted "Smitty" Smith

Page 34: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

16. cTbl. 348.22

Copyright 2008 Ted "Smitty" Smith

Page 35: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

17. Which of the following listed conduits does the NEC® permit to enclose conductors feeding wet-niche underwater pool lights?

a. Electrical metallic tubing (EMT)

b. Electrical nonmetallic tubing (ENT)

c. Galvanized rigid metal conduit (RMC)

d. Schedule 40 rigid polyvinyl chloride conduit (PVC)

Copyright 2008 Ted "Smitty" Smith

Page 36: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

17. d680.23(B)(2)

Copyright 2008 Ted "Smitty" Smith

Page 37: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

18. Underground wiring is not permitted under a swimming pool or within _____ of the pool unless the wiring is supplying pool equipment.

a. 10 feet

b. 6 feet

c. 5 feet

d. 8 feet

Copyright 2008 Ted "Smitty" Smith

Page 38: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

18. c680.10

Copyright 2008 Ted "Smitty" Smith

Page 39: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

19. Which of the following listed types of batteries is NOT permitted for use as a source of power for emergency systems?

a. Automotive

b. Lead acid type

c. Alkali type

d. All of these

Copyright 2008 Ted "Smitty" Smith

Page 40: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

19. a700.12(A)

Copyright 2008 Ted "Smitty" Smith

Page 41: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

20. The MINIMUM rating for a service disconnecting means for a building, other than a one-family dwelling, consisting of three, two-wire circuits shall be _____.

a. 15 amperes

b. 30 amperes

c. 60 amperes

d. 100 amperes

Copyright 2008 Ted "Smitty" Smith

Page 42: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

20. c230.79(D)

Copyright 2008 Ted "Smitty" Smith

Page 43: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

End of Drill Click the left mouse button to

advance back to the first question. Each question will now be repeated without the timer to give you a chance to review it and find the answer.

Clicking the left mouse button will advance the slide to the answer and the code

reference.

Copyright 2008 Ted "Smitty" Smith

Page 44: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

1. A listed instantaneous water heater shall be permitted to be subdivided into circuits protected at NOT more than _____.

a. 60 amperesb. 100 amperesc. 120 amperesd. 150 amperes

Copyright 2008 Ted "Smitty" Smith

Page 45: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

1. d 422.11(F)(3)

Copyright 2008 Ted "Smitty" Smith

Page 46: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

2. The interior of enclosures or raceways installed underground shall be considered to be a ______.

a. Wet location

b. Damp location

c. Moist location

d. Dry location

Copyright 2008 Ted "Smitty" Smith

Page 47: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

2. a 300.5(B)

Copyright 2008 Ted "Smitty" Smith

Page 48: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

3. The continuity of the grounding conductor system for portable electrical carnival equipment shall be verified _____.

a. And recorded on an annual basis

b. And recorded on a quarterly basis

c. And recorded on a monthly basis

d. Each time the equipment is connected

Copyright 2008 Ted "Smitty" Smith

Page 49: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

3. d 525.32

Copyright 2008 Ted "Smitty" Smith

Page 50: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

4. A plate type grounding electrode shall be installed below the surface of the earth NOT less than _____.

a. 24 inches

b. 30 inches

c. 36 inches

d. 48 inches

Copyright 2008 Ted "Smitty" Smith

Page 51: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

4. b 250.53(H)

Copyright 2008 Ted "Smitty" Smith

Page 52: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

5. Determine the MAXIMUM allowable ampacity of a size 1/0 AWG THW copper current-carrying conductor installed in a common raceway with three other current-carrying conductors of the same size. Ambient temperature is 86ºF.

a. 150 amperes

b. 105 amperes

c. 112 amperes

d. 120 amperes

Copyright 2008 Ted "Smitty" Smith

Page 53: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

5. d Tbl. 310.16 Tbl. 310.15(B)(2)(a)

Size 1/0 AWG THW ampacity(before de-rating) = 150 amperes

150 amperes X 80% (adjustment factor)

= 120 amperes Copyright 2008 Ted "Smitty"

Smith

Page 54: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

6. The NEC® defines a continuous-load to be a load where the maximum current on the circuit is expected to continue for at least _____ hours or more.

a. 3

b. 4

c. 6

d. 8

Copyright 2008 Ted "Smitty" Smith

Page 55: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

6. a Art. 100

Copyright 2008 Ted "Smitty" Smith

Page 56: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

7. Determine the MINIMUM size THW copper branch-circuit conductors required by the NEC® to supply a three-phase, continuous duty, AC motor that has a full-load current of 70 amperes. Assume all terminations to be rated at 75ºC.

a. 1 AWG

b. 2 AWG

c. 3 AWG

d. 4AWG

Copyright 2008 Ted "Smitty" Smith

Page 57: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

7. c 430.22(A) Tbl. 310.16 FLC of motor – 70 amperes X 125% = 87.5

amperes Size AWG THW conductors with an

ampacity of 100 amperes should be selected.

Copyright 2008 Ted "Smitty" Smith

Page 58: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

8. Given: you have determined a conductor has a computed allowable ampacity of 75 amperes. What is the MAXIMUM standard ampere rating of the overcurrent protection device the NEC® permits to protect this circuit? This is not a motor circuit or part of a multi-outlet branch-circuit supplying receptacles.

a. 70 amperes

b. 75 amperes

c. 80 amperes

d. 85 amperes

Copyright 2008 Ted "Smitty" Smith

Page 59: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

8. c 240.4(B)(2)&(3) 240.6(A)

Copyright 2008 Ted "Smitty" Smith

Page 60: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

9. A 208-volt, three-phase, 50HP, squirrel-cage, continuous duty, Design C, AC motor has a full-load running current of ______.

a. 130 amperes

b. 143 amperes

c. 162 amperes

d. 195 amperes

Copyright 2008 Ted "Smitty" Smith

Page 61: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

9. b Tbl. 430.250

Copyright 2008 Ted "Smitty" Smith

Page 62: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

10. Which of the following metal piping systems contained in a building is/are required to be bonded?

a. A gas pipe for a gas heaterb. A bathroom copper water pipe, connected

to an electric water heater.c. An air line for compressed aird. All these need to be bonded.

Copyright 2008 Ted "Smitty" Smith

Page 63: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

10. d250.104(B)

Copyright 2008 Ted "Smitty" Smith

Page 64: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

11. Determine the MINIMUM trade size electrical metallic tubing (EMT) required to enclose eight size 6 AWG copper conductors with THHW insulation, installed in a 60 foot conduit run.

a. 1 inch

b. 1 ¼ inch

c. 1 ½ inch

d. 2 inch

Copyright 2008 Ted "Smitty" Smith

Page 65: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

11. bAnnex C, Tbl. C. 1

Copyright 2008 Ted "Smitty" Smith

Page 66: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

12. When a feeder supplies a continuous-load of 240 amperes, in general, the overcurrent protection device protecting this circuit shall have a MINIMUM rating of _____.

a. 240 amperes

b. 300 amperes

c. 250 amperes

d. 275 amperes

Copyright 2008 Ted "Smitty" Smith

Page 67: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

12. b215.3 240 amperes X 125% = 300

amperes

Copyright 2008 Ted "Smitty" Smith

Page 68: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

13. In general, liquid-tight flexible metal conduit (LFMC) shall be securely fastened within _____ of each box or other conduit termination.

a. 4 ½ feet

b. 3 feet

c. 12 inches

d. 18 inches

Copyright 2008 Ted "Smitty" Smith

Page 69: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

13. c350.30(A)

Copyright 2008 Ted "Smitty" Smith

Page 70: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

14. When a pull box contains conductors of size 4 AWG and larger and a straight pull of the conductors is to be made, the length of the box shall NOT be less than _____ times the trade diameter of the largest conduit entering the box.

a. Six

b. Four

c. Eight

d. Twelve

Copyright 2008 Ted "Smitty" Smith

Page 71: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

14. c314.28(A)(1)

Copyright 2008 Ted "Smitty" Smith

Page 72: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

15. In general, all of the following wiring methods listed are permitted to be used as a feeder for temporary wiring on a construction site EXCEPT _____.

a. NM cable

b. NMC Cable

c. Type PD cord

d. Type SJO cord

Copyright 2008 Ted "Smitty" Smith

Page 73: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

15. c590.4(B) Tbl. 400.4

Copyright 2008 Ted "Smitty" Smith

Page 74: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

16. Determine the MAXIMUM number of size 14 AWG THHN conductors permitted to be installed in a trade size 3/8 inch flexible metal conduit (FMC) that contains a bare size 14 AWG grounding conductor when the flex has external fittings.

a. Two

b. Three

c. Four

d. five

Copyright 2008 Ted "Smitty" Smith

Page 75: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

16. cTbl. 348.22

Copyright 2008 Ted "Smitty" Smith

Page 76: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

17. Which of the following listed conduits does the NEC® permit to enclose conductors feeding wet-niche underwater pool lights?

a. Electrical metallic tubing (EMT)

b. Electrical nonmetallic tubing (ENT)

c. Galvanized rigid metal conduit (RMC)

d. Schedule 40 rigid polyvinyl chloride conduit (PVC)

Copyright 2008 Ted "Smitty" Smith

Page 77: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

17. d680.23(B)(2)

Copyright 2008 Ted "Smitty" Smith

Page 78: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

18. Underground wiring is not permitted under a swimming pool or within _____ of the pool unless the wiring is supplying pool equipment.

a. 10 feet

b. 6 feet

c. 5 feet

d. 8 feet

Copyright 2008 Ted "Smitty" Smith

Page 79: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

18. c680.10

Copyright 2008 Ted "Smitty" Smith

Page 80: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

19. Which of the following listed types of batteries is NOT permitted for use as a source of power for emergency systems?

a. Automotive

b. Lead acid type

c. Alkali type

d. All of these

Copyright 2008 Ted "Smitty" Smith

Page 81: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

19. a700.12(A)

Copyright 2008 Ted "Smitty" Smith

Page 82: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

20. The MINIMUM rating for a service disconnecting means for a building, other than a one-family dwelling, consisting of three, two-wire circuits shall be _____.

a. 15 amperes

b. 30 amperes

c. 60 amperes

d. 100 amperes

Copyright 2008 Ted "Smitty" Smith

Page 83: Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith

20. c230.79(D)

Copyright 2008 Ted "Smitty" Smith