INTERIOR INSTALLATION48" MAX O.C. MAIN TEE SPACING, TYP.
12" MAX BEAM
OVERHANG, TYP.
48" MAX O.C. HANGER WIRE SPACING, TYP.
12" MAX MAIN TEE
OVERHANG, TYP.
TYPICAL SYSTEM SECTIONSCALE: 3" = 1'-0"
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635,BY OTHERS, TYP.
2"
6"
TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.
2" HANGER BRACKETASSEMBLY
2" X 6" TAVOLA BEAM*2"
2"
BEAM SPECIFICATIONSSEE DETAIL A1.1
SUSPENSION SPECIFICATIONSSEE DETAIL A1.2
HANGER BRACKETASSEMBLYSEE DETAIL A1.3
12 GA HANGER WIRE, BY OTHERS,NOT BY CERTAINTEEDSEE DETAIL A1.2
15/16" HEAVY DUTY CLASS T-GRIDPER ASTM C635 BY OTHERSSEE DETAIL A1.2
6" BEAM SPACING SHOWN,
ACTUAL CAN VARY, TYP.
BEAM END CAPSEE DETAIL A1.4
*SEE DETAIL A1.1 FOR AVAILABLE BEAM SIZES
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
OVERALL ISOMETRIC VIEW
PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-LEV-A1.0
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
BEAM SIZES
BEAM SIZES ARE DIMENSIONED WIDTH X HEIGHT
PROFILES ARE AVAILABLE IN 1/2" INCREMENTS, CONTACTCERTAINTEED FOR OTHER SIZES
MAX LENGTHS MAY BE PROFILE-SPECIFIC, CONTACT CERTAINTEED
BEAM LENGTHS AVAILABLE IN ±1/4" INCREMENTS, MINIMUMQUANTITIES MAY APPLY
BEAM MATERIAL
.032", .040" ALUMINUM
BEAM FINISHES
PAINTED & POWDER COATED
DECORATED WOOD FINISH (POWDER COATED)
LAMINATED WOOD FINISH (FILM)
PERFORATIONS
STANDARD PERFORATION BORDERS ARE 1/4" NOM.
PERFORATION106
% OPEN16.0%
115 12.0%119 8.0%
1" - 24" WIDTH
TAVOLA
2" -
6" H
EIGH
T
1", 112", 2" WIDTH
TAVOLATALL
15" M
AX H
EIGH
T
12'-0" MAX BEAM LENGTH
HEIG
HT
BEAM END & SIDE VIEWSCALE: NOT TO SCALE
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
BEAM SPECIFICATIONS
PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-LEV-A1.1
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
INTERIOR INSTALLATION
48" MAX HANGER WIRE SPACING, TYP.
12" MAX MAIN TEE OVERHANG, TYP.
48" MAX MAIN TEE SPACING, TYP.
15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.
15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.
12 GA HANGER WIRE BY OTHERS, TYP.
TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.
2" HANGER BRACKET ASSEMBLY
2" X 6" TAVOLA BEAM SHOWN,ALL SIZES SIMILAR
15/16" CROSS TEE 48" O.C. MAX ALONGMAIN TEE, BY OTHERS, TYP.
TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.
2" HANGER BRACKET ASSEMBLY
48" MAX MAIN TEE SPACING, TYP.12 GA HANGER WIREBY OTHERS, TYP.
12" MAX BEAMOVERHANG, TYP.
2" X 6" TAVOLA BEAM SHOWN,ALL SIZES SIMILAR
2" X 6" TAVOLAEND CAP
15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.
SHALLOWER BEAMSBEYOND
TYPICAL SECTIONSSCALE: 3" = 1'-0"
TWO (2) MIN #6 FASTENERSPER BEAM/HANGERBRACKET, BY OTHERS, TYP.
12 GA HANGER WIRE BY OTHERS, TYP.
6" BEAM SPACING SHOWN,ACTUAL CAN VARY, TYP.
12" MAX MAIN TEEOVERHANG, TYP. 48" MAX HANGER WIRE SPACING, TYP.
15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE, BYOTHERS, TYP.
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635,BY OTHERS, TYP.
2" X 2" TAVOLABEAM
2" HANGER BRACKETASSEMBLY
2" X 6" TAVOLA BEAM SHOWN,ALL SIZES SIMILAR 2" X 4" TAVOLA BEAM
6" BEAM SPACING SHOWN,
ACTUAL CAN VARY, TYP.
NOTE:ATTACHMENT TO STRUCTUREDESIGNED AND PROVIDED BY OTHERS,NOT BY CERTAINTEED.
12" MAX BEAM
OVERHANG, TYP.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
SUSPENSION SPECIFICATIONS
PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-LEV-A1.2
SCALE: AS SHOWN
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
1
1
HANGER BRACKETASSEMBLY
SCISSOR CLIP
3
2
4
2-PIECE TAVOLA PRIME BEAMSREQUIRE 2 BOTTOM SPLICEPLATES PER SPLICE CONDITION
CRITICAL: SCISSOR CLIP WILL NOT FUNCTIONPROPERLY IF INSTALLED AT A CROSS TEE.SHIFT CROSS TEE LOCATIONS AS NECESSARY.
15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635
BOTTOM SPLICE PLATE WITHFACTORY-ATTACHEDDOUBLE-SIDED ADHESIVE
MIN #6 FASTENERSBY OTHERS, TYP.
*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR
TAVOLA BEAM
1 LIFT HANGER BRACKET ASSEMBLY INTOPOSITION ON MAIN TEE AND SQUEEZE SCISSORCLIP ONTO MAIN TEE WEB.
2 FEED FIRST TAVOLA BEAM HALFWAY ONTOHANGER BRACKET AND SECURE WITH TWO (2)MIN #6 FASTENERS (BY OTHERS).
3 REMOVE LINER FROM DOUBLE-SIDED ADHESIVEON BOTTOM SPLICE PLATE AND SECUREHALFWAY INTO FIRST TAVOLA BEAM.
FEED SECOND TAVOLA BEAM ONTO HANGERBRACKET ASSEMBLY AND BOTTOM PLATE.SECURE WITH TWO (2) MIN #6 FASTENERS.
NON-SPLICE LOCATIONS: ONLY TWO (2)FASTENERS (1 PER SIDE) ARE REQUIRED ANDBOTTOM PLATE IS OMITTED.
4
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
HANGER BRACKET ASSEMBLY INSTALLATION
PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-LEV-A1.3
SCALE: NOT TO SCALE
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
1 INSERT END CAP ONTO BEAMEND AND ENSURE CAP INSERTGOES INSIDE OF BEAM
2 SECURE END CAP WITH TWO (2)MIN #6 FASTENERS
METAL END CAP
PAINTED, POWDER COATED, &DECORATED WOOD FINISHES
INTEGRAL METAL END CAP
PAINTED & POWDER COATED FINISHES
END CAP IS FACTORY-FORMED ANDFACTORY-POP-RIVETED
MAY BE LIMITED BY PROFILE SIZE ANDBEAM LENGTH
*2" X 6" BEAM SHOWN, ALL SIZES SIMILAR
1
2
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
END CAP SPECIFICATIONS
PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-LEV-A1.4
SCALE: NOT TO SCALE
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.
WAVE PATTERN
2" X
2"
2" X
4"
2" X
6"
2" X
2"
2" X
4"
2" X
6"
2" X
4"
2" X
2"
2" X
4"
2" X
6"
2" X
6"
2" X
4"
2" X
4"
3" X
4"
1" X
4"
2" X
4"
3" X
6"
1"x2
"
3" X
4"
2" X
6"
1" X
4"
2" X
2"
2" X
2"
2" X
6"
2" X
4"
6" O.C. BEAM SPACING,ACTUAL CAN VARY
2'-0" PATTERN MODULE
6" O.C. BEAM SPACING,ACTUAL CAN VARY
2'-0" PATTERN MODULE
BARCODE PATTERN
6" O.C. BEAM SPACING,ACTUAL CAN VARY
1'-6" PATTERN MODULE
STEP PATTERN STAGGER PATTERN
6" O.C. BEAM SPACING,ACTUAL CAN VARY
3'-0" PATTERN MODULE
2'-0" PATTERN MODULE
CHOPPY PATTERN SCATTER PATTERN
6" O.C. BEAM SPACING,ACTUAL CAN VARY
2'-0" PATTERN MODULE
6" O.C. BEAM SPACING,ACTUAL CAN VARY
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
O 800 366 4327
F 770 806 0214
www.certainteed.com/architectural
SPECIFICATIONS
(unless noted otherwise)
MATERIAL: .032" | .040" ALUMINUM
FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED
WOOD FINISH
PERFORATION: NON-PERFORATED | #106 | #115 | #119
TAVOLA LEVELS PATTERNS
PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS
DRAWING NUMBER: TAVOLA-LEV-A1.5
SCALE: NOT TO SCALE
DRAWN BY: CTA ENGINEERING
DATE: 6/1/21
These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an
architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable
for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the
fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure
compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.