6
INTERIOR INSTALLATION 48" MAX O.C. MAIN TEE SPACING, TYP. 12" MAX BEAM OVERHANG, TYP. 48" MAX O.C. HANGER WIRE SPACING, TYP. 12" MAX MAIN TEE OVERHANG, TYP. TYPICAL SYSTEM SECTION SCALE: 3" = 1'-0" 15/16" HEAVY DUTY CLASS MAIN TEE PER ASTM C635, BY OTHERS, TYP. 2" 6" TWO (2) MIN #6 FASTENERS PER BEAM/ HANGER BRACKET, BY OTHERS, TYP. 2" HANGER BRACKET ASSEMBLY 2" X 6" TAVOLA BEAM* 2" 2" BEAM SPECIFICATIONS SEE DETAIL A1.1 SUSPENSION SPECIFICATIONS SEE DETAIL A1.2 HANGER BRACKET ASSEMBLY SEE DETAIL A1.3 12 GA HANGER WIRE, BY OTHERS, NOT BY CERTAINTEED SEE DETAIL A1.2 15/16" HEAVY DUTY CLASS T-GRID PER ASTM C635 BY OTHERS SEE DETAIL A1.2 6" BEAM SPACING SHOWN, ACTUAL CAN VARY, TYP. BEAM END CAP SEE DETAIL A1.4 *SEE DETAIL A1.1 FOR AVAILABLE BEAM SIZES 5015 Oakbrook Parkway, Suite 100 Norcross, GA 30093 O 800 366 4327 F 770 806 0214 www.certainteed.com/architectural SPECIFICATIONS (unless noted otherwise) MATERIAL: .032" | .040" ALUMINUM FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED WOOD FINISH PERFORATION: NON-PERFORATED | #106 | #115 | #119 OVERALL ISOMETRIC VIEW PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS DRAWING NUMBER: TAVOLA-LEV-A1.0 SCALE: AS SHOWN DRAWN BY: CTA ENGINEERING DATE: 6/1/21 These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

TWO (2) MIN #6 FASTENERS PER BEAM/ 12 MAX MAIN TEE

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TWO (2) MIN #6 FASTENERS PER BEAM/ 12 MAX MAIN TEE

INTERIOR INSTALLATION48" MAX O.C. MAIN TEE SPACING, TYP.

12" MAX BEAM

OVERHANG, TYP.

48" MAX O.C. HANGER WIRE SPACING, TYP.

12" MAX MAIN TEE

OVERHANG, TYP.

TYPICAL SYSTEM SECTIONSCALE: 3" = 1'-0"

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635,BY OTHERS, TYP.

2"

6"

TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.

2" HANGER BRACKETASSEMBLY

2" X 6" TAVOLA BEAM*2"

2"

BEAM SPECIFICATIONSSEE DETAIL A1.1

SUSPENSION SPECIFICATIONSSEE DETAIL A1.2

HANGER BRACKETASSEMBLYSEE DETAIL A1.3

12 GA HANGER WIRE, BY OTHERS,NOT BY CERTAINTEEDSEE DETAIL A1.2

15/16" HEAVY DUTY CLASS T-GRIDPER ASTM C635 BY OTHERSSEE DETAIL A1.2

6" BEAM SPACING SHOWN,

ACTUAL CAN VARY, TYP.

BEAM END CAPSEE DETAIL A1.4

*SEE DETAIL A1.1 FOR AVAILABLE BEAM SIZES

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

OVERALL ISOMETRIC VIEW

PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-LEV-A1.0

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 2: TWO (2) MIN #6 FASTENERS PER BEAM/ 12 MAX MAIN TEE

BEAM SIZES

BEAM SIZES ARE DIMENSIONED WIDTH X HEIGHT

PROFILES ARE AVAILABLE IN 1/2" INCREMENTS, CONTACTCERTAINTEED FOR OTHER SIZES

MAX LENGTHS MAY BE PROFILE-SPECIFIC, CONTACT CERTAINTEED

BEAM LENGTHS AVAILABLE IN ±1/4" INCREMENTS, MINIMUMQUANTITIES MAY APPLY

BEAM MATERIAL

.032", .040" ALUMINUM

BEAM FINISHES

PAINTED & POWDER COATED

DECORATED WOOD FINISH (POWDER COATED)

LAMINATED WOOD FINISH (FILM)

PERFORATIONS

STANDARD PERFORATION BORDERS ARE 1/4" NOM.

PERFORATION106

% OPEN16.0%

115 12.0%119 8.0%

1" - 24" WIDTH

TAVOLA

2" -

6" H

EIGH

T

1", 112", 2" WIDTH

TAVOLATALL

15" M

AX H

EIGH

T

12'-0" MAX BEAM LENGTH

HEIG

HT

BEAM END & SIDE VIEWSCALE: NOT TO SCALE

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

BEAM SPECIFICATIONS

PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-LEV-A1.1

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 3: TWO (2) MIN #6 FASTENERS PER BEAM/ 12 MAX MAIN TEE

INTERIOR INSTALLATION

48" MAX HANGER WIRE SPACING, TYP.

12" MAX MAIN TEE OVERHANG, TYP.

48" MAX MAIN TEE SPACING, TYP.

15/16" CROSS TEE 48" O.C. MAXALONG MAIN TEE, TYP.

15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.

12 GA HANGER WIRE BY OTHERS, TYP.

TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.

2" HANGER BRACKET ASSEMBLY

2" X 6" TAVOLA BEAM SHOWN,ALL SIZES SIMILAR

15/16" CROSS TEE 48" O.C. MAX ALONGMAIN TEE, BY OTHERS, TYP.

TWO (2) MIN #6 FASTENERS PER BEAM/HANGER BRACKET, BY OTHERS, TYP.

2" HANGER BRACKET ASSEMBLY

48" MAX MAIN TEE SPACING, TYP.12 GA HANGER WIREBY OTHERS, TYP.

12" MAX BEAMOVERHANG, TYP.

2" X 6" TAVOLA BEAM SHOWN,ALL SIZES SIMILAR

2" X 6" TAVOLAEND CAP

15/16" HEAVY DUTY CLASS MAIN TEEPER ASTM C635, BY OTHERS, TYP.

SHALLOWER BEAMSBEYOND

TYPICAL SECTIONSSCALE: 3" = 1'-0"

TWO (2) MIN #6 FASTENERSPER BEAM/HANGERBRACKET, BY OTHERS, TYP.

12 GA HANGER WIRE BY OTHERS, TYP.

6" BEAM SPACING SHOWN,ACTUAL CAN VARY, TYP.

12" MAX MAIN TEEOVERHANG, TYP. 48" MAX HANGER WIRE SPACING, TYP.

15/16" CROSS TEE 48" O.C.MAX ALONG MAIN TEE, BYOTHERS, TYP.

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635,BY OTHERS, TYP.

2" X 2" TAVOLABEAM

2" HANGER BRACKETASSEMBLY

2" X 6" TAVOLA BEAM SHOWN,ALL SIZES SIMILAR 2" X 4" TAVOLA BEAM

6" BEAM SPACING SHOWN,

ACTUAL CAN VARY, TYP.

NOTE:ATTACHMENT TO STRUCTUREDESIGNED AND PROVIDED BY OTHERS,NOT BY CERTAINTEED.

12" MAX BEAM

OVERHANG, TYP.

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

SUSPENSION SPECIFICATIONS

PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-LEV-A1.2

SCALE: AS SHOWN

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 4: TWO (2) MIN #6 FASTENERS PER BEAM/ 12 MAX MAIN TEE

1

1

HANGER BRACKETASSEMBLY

SCISSOR CLIP

3

2

4

2-PIECE TAVOLA PRIME BEAMSREQUIRE 2 BOTTOM SPLICEPLATES PER SPLICE CONDITION

CRITICAL: SCISSOR CLIP WILL NOT FUNCTIONPROPERLY IF INSTALLED AT A CROSS TEE.SHIFT CROSS TEE LOCATIONS AS NECESSARY.

15/16" HEAVY DUTY CLASSMAIN TEE PER ASTM C635

BOTTOM SPLICE PLATE WITHFACTORY-ATTACHEDDOUBLE-SIDED ADHESIVE

MIN #6 FASTENERSBY OTHERS, TYP.

*VERTICAL SUPPORT OMITTED FOR CLARITY**2" X 6" BEAM SHOWN, ALL SIZES SIMILAR

TAVOLA BEAM

1 LIFT HANGER BRACKET ASSEMBLY INTOPOSITION ON MAIN TEE AND SQUEEZE SCISSORCLIP ONTO MAIN TEE WEB.

2 FEED FIRST TAVOLA BEAM HALFWAY ONTOHANGER BRACKET AND SECURE WITH TWO (2)MIN #6 FASTENERS (BY OTHERS).

3 REMOVE LINER FROM DOUBLE-SIDED ADHESIVEON BOTTOM SPLICE PLATE AND SECUREHALFWAY INTO FIRST TAVOLA BEAM.

FEED SECOND TAVOLA BEAM ONTO HANGERBRACKET ASSEMBLY AND BOTTOM PLATE.SECURE WITH TWO (2) MIN #6 FASTENERS.

NON-SPLICE LOCATIONS: ONLY TWO (2)FASTENERS (1 PER SIDE) ARE REQUIRED ANDBOTTOM PLATE IS OMITTED.

4

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

HANGER BRACKET ASSEMBLY INSTALLATION

PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-LEV-A1.3

SCALE: NOT TO SCALE

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 5: TWO (2) MIN #6 FASTENERS PER BEAM/ 12 MAX MAIN TEE

1 INSERT END CAP ONTO BEAMEND AND ENSURE CAP INSERTGOES INSIDE OF BEAM

2 SECURE END CAP WITH TWO (2)MIN #6 FASTENERS

METAL END CAP

PAINTED, POWDER COATED, &DECORATED WOOD FINISHES

INTEGRAL METAL END CAP

PAINTED & POWDER COATED FINISHES

END CAP IS FACTORY-FORMED ANDFACTORY-POP-RIVETED

MAY BE LIMITED BY PROFILE SIZE ANDBEAM LENGTH

*2" X 6" BEAM SHOWN, ALL SIZES SIMILAR

1

2

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

END CAP SPECIFICATIONS

PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-LEV-A1.4

SCALE: NOT TO SCALE

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

Page 6: TWO (2) MIN #6 FASTENERS PER BEAM/ 12 MAX MAIN TEE

WAVE PATTERN

2" X

2"

2" X

4"

2" X

6"

2" X

2"

2" X

4"

2" X

6"

2" X

4"

2" X

2"

2" X

4"

2" X

6"

2" X

6"

2" X

4"

2" X

4"

3" X

4"

1" X

4"

2" X

4"

3" X

6"

1"x2

"

3" X

4"

2" X

6"

1" X

4"

2" X

2"

2" X

2"

2" X

6"

2" X

4"

6" O.C. BEAM SPACING,ACTUAL CAN VARY

2'-0" PATTERN MODULE

6" O.C. BEAM SPACING,ACTUAL CAN VARY

2'-0" PATTERN MODULE

BARCODE PATTERN

6" O.C. BEAM SPACING,ACTUAL CAN VARY

1'-6" PATTERN MODULE

STEP PATTERN STAGGER PATTERN

6" O.C. BEAM SPACING,ACTUAL CAN VARY

3'-0" PATTERN MODULE

2'-0" PATTERN MODULE

CHOPPY PATTERN SCATTER PATTERN

6" O.C. BEAM SPACING,ACTUAL CAN VARY

2'-0" PATTERN MODULE

6" O.C. BEAM SPACING,ACTUAL CAN VARY

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800 366 4327

F 770 806 0214

www.certainteed.com/architectural

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LAMINATED

WOOD FINISH

PERFORATION: NON-PERFORATED | #106 | #115 | #119

TAVOLA LEVELS PATTERNS

PROJECT: TAVOLA LEVELS PRODUCT SPECIFICATIONS

DRAWING NUMBER: TAVOLA-LEV-A1.5

SCALE: NOT TO SCALE

DRAWN BY: CTA ENGINEERING

DATE: 6/1/21

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an

architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable

for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the

fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure

compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.