The FV3 tunnel lighting luminaire, with front access, offers a wide varietyof light distribution levels. It can be fitted with any type of lamp and isavailable in a wide variety of lengths.
In all its configurations, the FV3 offers front access by a continuous hinge/closure system.
FV3
Tunnel lighting
Front access
APPLICATIONS
Symmetrical and asymmetrical lighting of road and motorway
tunnels and subways.
ADVANTAGES
- Integration of any type of source that can be used in tunnels
(high and low-pressure sodium, fluorescent, compact fluores-
cent), for all power ratings with one or two lamps positioned
end to end or parallel (see table of lamps).
- The diversity of its accessories and lengths means that the
FV3 can be used to light up all underground road or motorway
installation zones.
DESCRIPTION
Tight luminaire with front access consisting of the following
components:
obody and continuous hinge/closure system: extruded alumi-
nium protected by electrolytic oxidation (class 15);
otwo side plates: die-cast aluminium protected by hot polyes-
ter powdering;
oclear or frosted safety protector glass with or without screen-
printing;
opull-out reflector made of anodised aluminium;
opull-out control gear plate;
oindependent mounting system.
CHARACTERISTICS
Tightness IP 65
Impact resistance (glass) IK 08
Aerodynamic resistance (CxS)
Example: length 1130 mm Front: 0,223 m2
Side: 0,061 m2
Insulation I ou II
According to standard EN 60598-1 and 2/3
The FV3 luminaires are mounted at four points.
The materials of the suspended mounting parts (AG3 alumi-
nium, 316 stainless steel or Modar) and the screws and bolts
INSTALLATION
are adapted to the conditions of use and to the nature of the
materials in direct contact with them.
FV3
With 'Z'-shaped brackets
A = 90 mm with ± 10 mm transversal adjustment
• Tilting
• Partial������
• Total (Please consult us)������
• Swivelling
• Horizontal (± 5°)
• Swivelling and adjustable(luminaire/wall distance)
• Swivelling and adjustable
(3 directions)
1. Fixed suspended mounting
II. Pull-out suspended mountings
II. Recessing
A
A
A
A
A
≥80mm
>130mm
310
<33
0m
m
240 mm
30 m
m80
mm
50 mm
One or two compression glands (Ø 13 - 16 - 21 mm) Tight, pull-out base (3 or 5 contacts) Output cable and tight, pull-out plug (3 or 5 contacts)
ELECTRICAL INSTALLATION
DIMENSIONS
Tool-free access to the reflector, lamp and control gear.
MAINTENANCE
After undoing the continuous closure system, the protector
glass tilts around a continuous hinge system.
The glass is easy to dismantle and replace.
The control gear is placed on a pull-out plate. Its positioning -
next to or behind the reflector - depends on the choice of
lamp, the number of lamps and the type of reflector.
130 mm
282 mm
193
mm
variable (see lamps table)
OPTIONS
- Narrow beam systems
• frosted glass for applications with high-pressure sodium
lamps
• bidirectional internal louvres
• unidirectional internal louvres
- Fuses
- Colour filters
LAMPS
480mm9kg
760mm14,5kg
480mm9kg
760mm14,5kg
560mm9,54kg
1130mm18kg
83/1430/1529
70 W
560mm9,5kg
760mm15kg
560mm10kg
1130mm18,5kg
560mm10kg
1130mm18,5kg
100 W
560mm10,5kg
1130mm20kg
760mm12kg
1550mm24kg
560mm10,5kg
1130mm20kg
150 W
760mm13,5kg
1550mm27kg
760mm13,5kg
1550mm27kg
250 W
760mm15,5kg
1550mm31kg
760mm15,5kg
1550mm31kg
400 W
High pressure sodium
168 1200
450mm9kg
790mm15kg
450mm9kg
790mm15kg
83/168/1002/1424/1429/1089
560mm10kg
1040mm17kg
560mm10kg
1040mm17kg
670mm10,5kg
1260mm20kg
1240mm13,5kg
1550mm23kg
Low pressure sodium
1518
1320mm18,5kg
1320mm20,5kg
1320mm20,5kg
83/168/1424/1099/1297
36 W
1620mm21kg
1620mm23kg
1620mm23kg
58 W
Fluorescent (Ø 26 mm)
1192
570mm10kg
1240mm20kg
570mm10kg
570mm12kg
1240mm22kg
1240mm24kg
83/168/1297/1089/1518
36 W
670mm11kg
1240mm20kg
670mm11kg
670mm13kg
1240mm22kg
1240mm24kg
40-55 W
Compact fluorescent
1192
35 W
E 26 W
55 W
E 36 W
90 W
E 66 W
135 W
E 91 W
180 W
E 131 W
behind the reflector
end of the reflector
type of reflector
Control gear localization
Ceiling - central
FV3
PHOTOMETRY
Ceiling - central
Reflector 168
2 x 58 W fluorescent
420 210280350 140 70
90°/270° 0°/180°
Ceiling - central
Reflector 83
1 x 180 W low-pressure sodium
270 135180225 90 45
270°/90° 0°/180°
Ceiling - central
Reflector 1529
1 x 400 W high-pressure sodium
420 210280350 140 70
270°/90° 0°/180°
Ceiling - central
Reflector 1200
1 x 150 W high-pressure sodium
420 210280350 140 70
270°/90° 15°/165°
Ceiling - side
Ceiling - side
Reflector 1518
1 x 36 W low-pressure sodium
420 210280350 140 70
270°/90° 0°/180°
Ceiling - side
Reflector 83
1 x 400 W high-pressure sodium
480 240320400 160 80
270°/90° 0°/180°
FV3
Corner
Corner
Reflector 1430
1 x 400 W high-pressure sodium
660 330440550 220 110
280°/90° 0°/180°
Corner
Reflector 1002
1 x 180 W low-pressure sodium
480 240320400 160 80
270°/90° 0°/180°
Corner
Reflector 1089
2 x 58 fluorescent
420 210280350 140 70
270°/90°
Side walls
Side walls
Reflector 1424
1 x 180 W low-pressure sodium
420 210280350 140 70
270°/90° 0°/180°
Corner
Reflector 1257
2 x 58 W fluorescent
270 135180225 90 45
270°/90°