6
The FV3 tunnel lighting luminaire, with front access, offers a wide variety of light distribution levels. It can be fitted with any type of lamp and is available in a wide variety of lengths. In all its configurations, the FV3 offers front access by a continuous hinge/closure system. FV3 Tunnel lighting Front access APPLICATIONS Symmetrical and asymmetrical lighting of road and motorway tunnels and subways. ADVANTAGES - Integration of any type of source that can be used in tunnels (high and low-pressure sodium, fluorescent, compact fluores- cent), for all power ratings with one or two lamps positioned end to end or parallel (see table of lamps). - The diversity of its accessories and lengths means that the FV3 can be used to light up all underground road or motorway installation zones. DESCRIPTION Tight luminaire with front access consisting of the following components: obody and continuous hinge/closure system: extruded alumi- nium protected by electrolytic oxidation (class 15); otwo side plates: die-cast aluminium protected by hot polyes- ter powdering; oclear or frosted safety protector glass with or without screen- printing; opull-out reflector made of anodised aluminium; opull-out control gear plate; oindependent mounting system. CHARACTERISTICS Tightness IP 65 Impact resistance (glass) IK 08 Aerodynamic resistance (CxS) Example: length 1130 mm Front: 0,223 m 2 Side: 0,061 m 2 Insulation I ou II According to standard EN 60598-1 and 2/3

tunnel lighting 7

Embed Size (px)

DESCRIPTION

tunnel lighting

Citation preview

Page 1: tunnel lighting 7

The FV3 tunnel lighting luminaire, with front access, offers a wide varietyof light distribution levels. It can be fitted with any type of lamp and isavailable in a wide variety of lengths.

In all its configurations, the FV3 offers front access by a continuous hinge/closure system.

FV3

Tunnel lighting

Front access

APPLICATIONS

Symmetrical and asymmetrical lighting of road and motorway

tunnels and subways.

ADVANTAGES

- Integration of any type of source that can be used in tunnels

(high and low-pressure sodium, fluorescent, compact fluores-

cent), for all power ratings with one or two lamps positioned

end to end or parallel (see table of lamps).

- The diversity of its accessories and lengths means that the

FV3 can be used to light up all underground road or motorway

installation zones.

DESCRIPTION

Tight luminaire with front access consisting of the following

components:

obody and continuous hinge/closure system: extruded alumi-

nium protected by electrolytic oxidation (class 15);

otwo side plates: die-cast aluminium protected by hot polyes-

ter powdering;

oclear or frosted safety protector glass with or without screen-

printing;

opull-out reflector made of anodised aluminium;

opull-out control gear plate;

oindependent mounting system.

CHARACTERISTICS

Tightness IP 65

Impact resistance (glass) IK 08

Aerodynamic resistance (CxS)

Example: length 1130 mm Front: 0,223 m2

Side: 0,061 m2

Insulation I ou II

According to standard EN 60598-1 and 2/3

Page 2: tunnel lighting 7

The FV3 luminaires are mounted at four points.

The materials of the suspended mounting parts (AG3 alumi-

nium, 316 stainless steel or Modar) and the screws and bolts

INSTALLATION

are adapted to the conditions of use and to the nature of the

materials in direct contact with them.

FV3

With 'Z'-shaped brackets

A = 90 mm with ± 10 mm transversal adjustment

• Tilting

• Partial������

• Total (Please consult us)������

• Swivelling

• Horizontal (± 5°)

• Swivelling and adjustable(luminaire/wall distance)

• Swivelling and adjustable

(3 directions)

1. Fixed suspended mounting

II. Pull-out suspended mountings

II. Recessing

A

A

A

A

A

≥80mm

>130mm

310

<33

0m

m

240 mm

30 m

m80

mm

50 mm

Page 3: tunnel lighting 7

One or two compression glands (Ø 13 - 16 - 21 mm) Tight, pull-out base (3 or 5 contacts) Output cable and tight, pull-out plug (3 or 5 contacts)

ELECTRICAL INSTALLATION

DIMENSIONS

Tool-free access to the reflector, lamp and control gear.

MAINTENANCE

After undoing the continuous closure system, the protector

glass tilts around a continuous hinge system.

The glass is easy to dismantle and replace.

The control gear is placed on a pull-out plate. Its positioning -

next to or behind the reflector - depends on the choice of

lamp, the number of lamps and the type of reflector.

130 mm

282 mm

193

mm

variable (see lamps table)

OPTIONS

- Narrow beam systems

• frosted glass for applications with high-pressure sodium

lamps

• bidirectional internal louvres

• unidirectional internal louvres

- Fuses

- Colour filters

Page 4: tunnel lighting 7

LAMPS

480mm9kg

760mm14,5kg

480mm9kg

760mm14,5kg

560mm9,54kg

1130mm18kg

83/1430/1529

70 W

560mm9,5kg

760mm15kg

560mm10kg

1130mm18,5kg

560mm10kg

1130mm18,5kg

100 W

560mm10,5kg

1130mm20kg

760mm12kg

1550mm24kg

560mm10,5kg

1130mm20kg

150 W

760mm13,5kg

1550mm27kg

760mm13,5kg

1550mm27kg

250 W

760mm15,5kg

1550mm31kg

760mm15,5kg

1550mm31kg

400 W

High pressure sodium

168 1200

450mm9kg

790mm15kg

450mm9kg

790mm15kg

83/168/1002/1424/1429/1089

560mm10kg

1040mm17kg

560mm10kg

1040mm17kg

670mm10,5kg

1260mm20kg

1240mm13,5kg

1550mm23kg

Low pressure sodium

1518

1320mm18,5kg

1320mm20,5kg

1320mm20,5kg

83/168/1424/1099/1297

36 W

1620mm21kg

1620mm23kg

1620mm23kg

58 W

Fluorescent (Ø 26 mm)

1192

570mm10kg

1240mm20kg

570mm10kg

570mm12kg

1240mm22kg

1240mm24kg

83/168/1297/1089/1518

36 W

670mm11kg

1240mm20kg

670mm11kg

670mm13kg

1240mm22kg

1240mm24kg

40-55 W

Compact fluorescent

1192

35 W

E 26 W

55 W

E 36 W

90 W

E 66 W

135 W

E 91 W

180 W

E 131 W

behind the reflector

end of the reflector

type of reflector

Control gear localization

Page 5: tunnel lighting 7

Ceiling - central

FV3

PHOTOMETRY

Ceiling - central

Reflector 168

2 x 58 W fluorescent

420 210280350 140 70

90°/270° 0°/180°

Ceiling - central

Reflector 83

1 x 180 W low-pressure sodium

270 135180225 90 45

270°/90° 0°/180°

Ceiling - central

Reflector 1529

1 x 400 W high-pressure sodium

420 210280350 140 70

270°/90° 0°/180°

Ceiling - central

Reflector 1200

1 x 150 W high-pressure sodium

420 210280350 140 70

270°/90° 15°/165°

Ceiling - side

Ceiling - side

Reflector 1518

1 x 36 W low-pressure sodium

420 210280350 140 70

270°/90° 0°/180°

Ceiling - side

Reflector 83

1 x 400 W high-pressure sodium

480 240320400 160 80

270°/90° 0°/180°

Page 6: tunnel lighting 7

FV3

Corner

Corner

Reflector 1430

1 x 400 W high-pressure sodium

660 330440550 220 110

280°/90° 0°/180°

Corner

Reflector 1002

1 x 180 W low-pressure sodium

480 240320400 160 80

270°/90° 0°/180°

Corner

Reflector 1089

2 x 58 fluorescent

420 210280350 140 70

270°/90°

Side walls

Side walls

Reflector 1424

1 x 180 W low-pressure sodium

420 210280350 140 70

270°/90° 0°/180°

Corner

Reflector 1257

2 x 58 W fluorescent

270 135180225 90 45

270°/90°