5
Outdoor Luminaires > Tunnels and underpass > TubePoint gen Dear User. Hereby we would like to inform you, that our site and also this service will end on Decem ber st, . Please use the Philips product catalog for family and product pages at www.lighting.philips.com. If you received this page via thirdparty site, please inform their website administrator about this message. TubePoint GEN Luminaire range for trac tunnels Many tunnel authorities have an outdated tunnel lighting installation that urgently needs to be replaced, but have only limited budget available. We are able to fulll their requirements. TubePoint GEN is the result of years of experience in tunnel lighting combined with the latest technologies developed by Philips. With its modular design and modern LED architecture, TubePoint GEN is a versatile, costeective luminaire that meets the most stringent tunnel lighting requirements. It is made of highestquality components that are dedicated for tunnels, thus ensuring a long lifetime, good performance and low maintenance costs. The eciency and wide choice of optics means the number of luminaires can be reduced signicantly compared with a conventional solution. And a high lumen per watt ratio at system level improves the total cost of ownership. TubePoint GEN is part of Philips’ TotalTunnel solution for a complete tunnel lighting. Benets •Flexible mounting solution, quick release for easy maintenance •Easy connect, wide range of connectivity options •Excellent quality optics, longer distance between luminaires •Fast payback Features •Direct replacement of existing conventional luminaires (Lumen packages exceeding SONT W) •Flexibility in application thanks to a range of lumen outputs and tunnel optics •Compatible with Philips’ tunnel controls and options for thirdparty controls •Option of remote driver for quick and easy maintenance •Wide choice of mounting systems Application •Trac tunnels and underpasses Product Range A B C More info available online at: www.lighting.philips.com data subject to change Wednesday th February,

TubePoint GEN2 - Luminaire range for trac tunnels (en... · TubePoint GEN2 - Luminaire range for trac tunnels Many tunnel authorities have an outdated tunnel lighting installation

  • Upload
    others

  • View
    22

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TubePoint GEN2 - Luminaire range for trac tunnels (en... · TubePoint GEN2 - Luminaire range for trac tunnels Many tunnel authorities have an outdated tunnel lighting installation

Outdoor Luminaires > Tunnels and underpass > TubePoint gen2

Dear User.Hereby we would like to inform you, that our site and also this service will end on Decem-ber 31st, 2018. Please use the Philips product catalog for family and product pages atwww.lighting.philips.com.

If you received this page via third-party site, please inform their website administrator about thismessage.

TubePoint GEN2 - Luminaire range for tra�ctunnelsMany tunnel authorities have an outdated tunnel lighting installationthat urgently needs to be replaced, but have only limited budgetavailable. We are able to ful�ll their requirements. TubePoint GEN2 isthe result of years of experience in tunnel lighting combined with thelatest technologies developed by Philips. With its modular design andmodern LED architecture, TubePoint GEN2 is a versatile, cost-e�ectiveluminaire that meets the most stringent tunnel lighting requirements. Itis made of highest-quality components that are dedicated for tunnels,thus ensuring a long lifetime, good performance and low maintenancecosts. The e�ciency and wide choice of optics means the number ofluminaires can be reduced signi�cantly compared with a conventionalsolution. And a high lumen per watt ratio at system level improves thetotal cost of ownership. TubePoint GEN2 is part of Philips’ TotalTunnelsolution for a complete tunnel lighting.

Bene�ts•Flexible mounting solution, quick release for easy maintenance•Easy connect, wide range of connectivity options•Excellent quality optics, longer distance between luminaires•Fast payback

Features•Direct replacement of existing conventional luminaires (Lumenpackages exceeding SON-T 400 W)

•Flexibility in application thanks to a range of lumen outputs and tunneloptics

•Compatible with Philips’ tunnel controls and options for third-partycontrols

•Option of remote driver for quick and easy maintenance•Wide choice of mounting systems

Application•Tra�c tunnels and underpasses

Product Range

A B C

2019-02-21 More info available online at: www.lighting.philips.com data subject to change 1

16

'W

ed

ne

sday

20

thF

eb

rua

ry,2

01

9

Page 2: TubePoint GEN2 - Luminaire range for trac tunnels (en... · TubePoint GEN2 - Luminaire range for trac tunnels Many tunnel authorities have an outdated tunnel lighting installation

Outdoor Luminaires > Tunnels and underpass > TubePoint gen2

Detailed PhotosTubePoint_GEN2-BGP235_MBQ_M-

DPP.TIF

A

TubePoint_GEN2-BGP235_BA-DPP.TIF

B

TubePoint_GEN2-BGP235_MBA-DPP.TIF

C

TubePoint_GEN2-BGP235_MBQ_S-DPP.TIF

D

TubePoint_GEN2-BGP235_MBQ-S-2DPP.TIF

E

TubePoint_GEN2-BGP235_MBQ_L-DPP.TIF

F

TubePoint_GEN2-BGP235_MB-DPP.TIF

G

TubePoint_GEN2-BGP235_BA_SO-8DPP.TIF

H

TubePoint_GEN2-BGP235-2DPP.TIF

I

TubePoint_GEN2-BGP235-1DPP.TIF

J

TubePoint_GEN2-BGP236-2DPP.TIF

K

TubePoint_GEN2-BGP236-1DPP.TIF

L

TubePoint_GEN2-BGP237-1DPP.TIF

M

TubePoint_GEN2-BGP237-2DPP.TIF

N

Dimension Drawing

1 2 3

2019-02-21 More info available online at: www.lighting.philips.com data subject to change 2

16

'W

ed

ne

sday

20

thF

eb

rua

ry,2

01

9

Page 3: TubePoint GEN2 - Luminaire range for trac tunnels (en... · TubePoint GEN2 - Luminaire range for trac tunnels Many tunnel authorities have an outdated tunnel lighting installation

Outdoor Luminaires > Tunnels and underpass > TubePoint gen2

Technical Speci�cationType1 Lamp2 Driver/

power unit/trans-

former3

Optictype4

Opticalcover/lens

type5

Accessorycolor6

Initialinputpower

LuminousE�cacy(Rated)

Photoletter

Detailed Photomm

Ordering number8718699...

(W) (lm/W)

BGP235 LED30/740 PSD S FG BK 19 190 A A-J 1 48290900

BGP235 LED50/740 PSD S FG BK 32 177 A A-J 1 48291600

BGP235 LED90/740 PSD S FG BK 58 168 A A-J 1 48292300

BGP235 LED120/740 PSD S FG BK 75 171 A A-J 1 48293000

BGP235 LED180/740 PSD S FG BK 114 168 A A-J 1 48294700

BGP235 LED240/740 PSD S FG BK 149 171 A A-J 1 48295400

BGP236 LED360/740 PSD S FG BK 230 168 B A-H, K, L 2 48296100

BGP236 LED480/740 PSD S FG BK 295 171 B A-H, K, L 2 48297800

BGP237 LED540/740 PSD S FG BK 320 180 C A-H, M, N 3 48298500

BGP237 LED640/740 PSD S FG BK 383 175 C A-H, M, N 3 48299200

BGP237 LED740/740 PSD S FG BK 462 170 C A-H, M, N 3 483005001 ’Type’ value description(s): ’BGP235’ = TubePoint GEN2 Small, ’BGP236’ = TubePoint GEN2 Medium, ’BGP237’ = TubePoint GEN2 Large2 ’Lamp’ value description(s): ’LED120’ = LED module 12,000 lm, ’LED180’ = LED module 18,000 lm, ’LED240’ = LED module 24,000 lm,

’LED30’ = LED module 3,000 lm, ’LED360’ = LED module 36,000 lm, ’LED480’ = LED module 48,000 lm, ’LED50’ = LED module 5,000 lm,’LED540’ = LED module 54,000 lm, ’LED640’ = LED module 64,000 lm, ’LED740’ = LED module 74,000 lm, ’LED90’ = LED module 9,000 lm,’740’ = 740 neutral white

3 ’Driver/power unit/transformer’ value description(s): ’PSD’ = Power supply unit with DALI interface4 ’Optic type’ value description(s): ’S’ = Symmetrical5 ’Optical cover/lens type’ value description(s): ’FG’ = Flat glass6 ’Accessory color’ value description(s): ’BK’ = Black

Electrical dataType Input Frequency Input Voltage Lamp Power

TolerancePower Factor Inrush time Inrush current Initial input power

(Hz) (V) ( [min.]) (ms) (A) (W)

BGP235 50-60 220-240 +/-11% 0.95 0.34 22 19

BGP235 50-60 220-240 +/-11% 0.98 0.30 53 114

BGP235 50-60 220-240 +/-11% 0.98 0.25 46 58

BGP235 50-60 220-240 +/-11% 0.98 0.25 46 75

BGP235 50-60 220-240 +/-11% 0.98 0.29 22 32

BGP235 50-60 220-240 +/-11% 0.99 0.34 99 149

BGP236 50-60 220-240 +/-11% 0.98 0.30 53 230

BGP236 50-60 220-240 +/-11% 0.99 0.30 53 295

BGP237 50-60 220-240 +/-11% 0.98 0.30 53 320

BGP237 50-60 220-240 +/-11% 0.98 0.30 53 383

BGP237 50-60 220-240 +/-11% 0.99 0.30 53 462

Light technical dataType Lamp family

code7Light source

color8Init. Corr. Color

TemperatureColour

RenderingIndex

Initial chromaticity LuminousE�cacy(Rated)

Initialluminous �ux(system �ux)

Luminous �uxtolerance

(K) (lm/W) (lm)

BGP235 LED30 740 4000 >70 (0.3818, 3,796) SDCM<3 190 2,529 +/-7%

BGP235 LED50 740 4000 >70 (0.3818, 3,796) SDCM<3 177 4,206 +/-7%

BGP235 LED90 740 4000 >70 (0.3818, 3,796) SDCM<3 168 7,490 +/-7%

BGP235 LED120 740 4000 >70 (0.3818, 3,796) SDCM<3 171 9,918 +/-7%

BGP235 LED180 740 4000 >70 (0.3818, 3,796) SDCM<3 168 14,851 +/-7%

BGP235 LED240 740 4000 >70 (0.3818, 3,796) SDCM<3 171 19,708 +/-7%

BGP236 LED360 740 4000 >70 (0.3818, 3,796) SDCM<3 168 29,520 +/-7%

BGP236 LED480 740 4000 >70 (0.3818, 3,796) SDCM<3 171 39,360 +/-7%

BGP237 LED540 740 4000 >70 (0.3818, 3,796) SDCM<3 180 44,820 +/-7%

BGP237 LED640 740 4000 >70 (0.3818, 3,796) SDCM<3 175 52,480 +/-7%

BGP237 LED740 740 4000 >70 (0.3818, 3,796) SDCM<3 170 60,680 +/-7%7 ’Lamp family code’ value description(s): ’LED120’ = LED module 12,000 lm, ’LED180’ = LED module 18,000 lm, ’LED240’ = LED module 24,000 lm,

’LED30’ = LED module 3,000 lm, ’LED360’ = LED module 36,000 lm, ’LED480’ = LED module 48,000 lm, ’LED50’ = LED module 5,000 lm,’LED540’ = LED module 54,000 lm, ’LED640’ = LED module 64,000 lm, ’LED740’ = LED module 74,000 lm, ’LED90’ = LED module 9,000 lm

8 ’Light source color’ value description(s): ’740’ = 740 neutral white

2019-02-21 More info available online at: www.lighting.philips.com data subject to change 3

16

'W

ed

ne

sday

20

thF

eb

rua

ry,2

01

9

Page 4: TubePoint GEN2 - Luminaire range for trac tunnels (en... · TubePoint GEN2 - Luminaire range for trac tunnels Many tunnel authorities have an outdated tunnel lighting installation

Outdoor Luminaires > Tunnels and underpass > TubePoint gen2

Temperature dataCommercial product name Init. Corr. Color Temperature T-Ambient

(K) (°C)

BGP235 LED30-4S/740 DSM11 D9 MIO-CIO MBQ 4,000 -30 to +50 °C

BGP235 LED50-4S/740 DSM11 D9 MIO-CIO MBQ 4,000 -30 to +50 °C

BGP235 LED90-4S/740 DSM11 D9 MIO-CIO MBQ 4,000 -30 to +50 °C

BGP235 LED120-4S/740 DSM11 D9 MIO-CIO MB 4,000 -30 to +50 °C

BGP235 LED180-4S/740 DSM11 D9 MIO-CIO MB 4,000 -30 to +50 °C

BGP235 LED240-4S/740 DSM11 D9 MIO-CIO MB 4,000 -30 to +50 °C

BGP236 LED360-4S/740 DSM11 D9 MIO-CIO MB 4,000 -30 to +50 °C

BGP236 LED480-4S/740 DSM11 D9 MIO-CIO MB 4,000 -30 to +50 °C

BGP237 LED540-4S/740 DSM11 D9 MIO-CIO MB 4,000 -30 to +50 °C

BGP237 LED640-4S/740 DSM11 D9 MIO-CIO MB 4,000 -30 to +45 °C

BGP237 LED740-4S/740 DSM11 D9 MIO-CIO MB 4,000 -30 to +40 °C

Housing/Material dataType Colour9 Optic type10 Optical cover/

lens type11Optical cover/lens �nish12

Optical cover/lens shape13

Optical cover/lens material14

Opticmaterial15

Fixationmaterial16

HousingMaterial17

BGP235 BK S FG CL FT G PC SS ALD

BGP236 BK S FG CL FT G PC SS ALD

BGP237 BK S FG CL FT G PC SS ALD9 ’Colour’ value description(s): ’BK’ = Black10 ’Optic type’ value description(s): ’S’ = Symmetrical11 ’Optical cover/lens type’ value description(s): ’FG’ = Flat glass12 ’Optical cover/lens �nish’ value description(s): ’CL’ = Clear13 ’Optical cover/lens shape’ value description(s): ’FT’ = Flat14 ’Optical cover/lens material’ value description(s): ’G’ = Glass15 ’Optic material’ value description(s): ’PC’ = Polycarbonate16 ’Fixation material’ value description(s): ’SS’ = Stainless steel17 ’Housing Material’ value description(s): ’ALD’ = Aluminum die-cast

Extended Dimension dataType Overall length Overall height Overall width

(mm) (mm) (mm)

BGP235 363.5 89.5 485.5

BGP236 727.0 89.5 485.5

BGP237 1,090.6 89.5 485.5

Protection & classi�cation standardsType Protection class

IEC18Surge Protection

(Common/Differential)19

IPClassi�cation20

Mech. impactprotection

code21

CE mark ENEC mark Flammabilitymark22

RoHS mark

BGP235 I SRG6-6 IP66 IK08 CE ENEC F ROHS

BGP236 I SRG6-6 IP66 IK08 CE ENEC F ROHS

BGP237 I SRG6-6 IP66 IK08 CE ENEC F ROHS18 ’Protection class IEC’ value description(s): ’I’ = Safety class I19 ’Surge Protection (Common/Differential)’ value description(s): ’SRG6-6’ = Luminaire surge protection level until 6 kV di�erential mode and 6 kV common mode20 ’IP Classi�cation’ value description(s): ’IP66’ = Dust penetration-protected, jet-proof21 ’Mech. impact protection code’ value description(s): ’IK08’ = 5 J vandal-protected22 ’Flammability mark’ value description(s): ’F’ = For mounting on normally �ammable surfaces

Operating dataType Input Frequency Lamp Power Tolerance Constant light output

(Hz)

BGP235 50-60 +/-11% Yes No

BGP236 50-60 +/-11% Yes No

BGP237 50-60 +/-11% Yes No

2019-02-21 More info available online at: www.lighting.philips.com data subject to change 4

16

'W

ed

ne

sday

20

thF

eb

rua

ry,2

01

9

Page 5: TubePoint GEN2 - Luminaire range for trac tunnels (en... · TubePoint GEN2 - Luminaire range for trac tunnels Many tunnel authorities have an outdated tunnel lighting installation

Outdoor Luminaires > Tunnels and underpass > TubePoint gen2

EquipmentType Number of gear

units23Driver/power unit/

transformer24Driver included Control Interface Light source replaceable Standard tilt angle

side entry

(piece) (°)

BGP235 1 PSD Yes DALI Yes 0°

BGP236 2 PSD Yes DALI Yes 0°

BGP237 3 PSD Yes DALI Yes 0°23 ’Number of gear units’ value description(s): ’1’ = 1 unit, ’2’ = 2 units, ’3’ = 3 units24 ’Driver/power unit/transformer’ value description(s): ’PSD’ = Power supply unit with DALI interface

Miscellaneous dataType Maximum dim level E�ective projected

areaNumber of Productson MCB (16A Type

B)

Mounting device T-Ambient Warranty period

(m2) (°C)

BGP235 Yes 10% 0.18 8 MBQ-M -30 to +50 °C 5 years

BGP235 Yes 10% 0.18 11 MBQ-M -30 to +50 °C 5 years

BGP235 Yes 10% 0.18 20 MBQ-M -30 to +50 °C 5 years

BGP236 Yes 10% 0.36 4 MBQ-M -30 to +50 °C 5 years

BGP237 Yes 10% 0.53 2 MBQ-M -30 to +40 °C 5 years

BGP237 Yes 10% 0.53 2 MBQ-M -30 to +45 °C 5 years

BGP237 Yes 10% 0.53 2 MBQ-M -30 to +50 °C 5 years

Logistic dataCommercial product name SAP

Packing(Piece)/Pack-

agingcon�gura-

tion25

Numerator- Packs per

outer box

Ordering number8718699...

Material Nr.(12NC)

SAP GrossWeight(Piece)

Net Weight(Piece)

EAN-38718699...

(9123...) (g) (g)

BGP235 LED30-4S/740 DSM11 D9 MIO-CIO MBQ UNP / 1 1 48290900 00024108 7,000 6,650 482909

BGP235 LED50-4S/740 DSM11 D9 MIO-CIO MBQ UNP / 1 1 48291600 00024109 7,000 6,650 482916

BGP235 LED90-4S/740 DSM11 D9 MIO-CIO MBQ UNP / 1 1 48292300 00024110 7,000 6,650 482923

BGP235 LED120-4S/740 DSM11 D9 MIO-CIO MB UNP / 1 1 48293000 00024111 7,000 6,650 482930

BGP235 LED180-4S/740 DSM11 D9 MIO-CIO MB UNP / 1 1 48294700 00024112 7,000 6,650 482947

BGP235 LED240-4S/740 DSM11 D9 MIO-CIO MB UNP / 1 1 48295400 00024113 7,000 6,650 482954

BGP236 LED360-4S/740 DSM11 D9 MIO-CIO MB UNP / 1 1 48296100 00024114 14,000 13,300 482961

BGP236 LED480-4S/740 DSM11 D9 MIO-CIO MB UNP / 1 1 48297800 00024115 14,000 13,300 482978

BGP237 LED540-4S/740 DSM11 D9 MIO-CIO MB UNP / 1 1 48298500 00024116 23,000 21,850 482985

BGP237 LED640-4S/740 DSM11 D9 MIO-CIO MB UNP / 1 1 48299200 00024117 23,000 21,850 482992

BGP237 LED740-4S/740 DSM11 D9 MIO-CIO MB UNP / 1 1 48300500 00024118 23,000 21,850 48300525 ’SAP Packing (Piece)/Packaging con�guration’ value description(s): ’UNP / 1’ = UNPACKED

Codes - Application dataCommercial product name Type26

BGP235 LED30-4S/740 DSM11 D9 MIO-CIO MBQ BGP235

BGP235 LED50-4S/740 DSM11 D9 MIO-CIO MBQ BGP235

BGP235 LED90-4S/740 DSM11 D9 MIO-CIO MBQ BGP235

BGP235 LED120-4S/740 DSM11 D9 MIO-CIO MB BGP235

BGP235 LED180-4S/740 DSM11 D9 MIO-CIO MB BGP235

BGP235 LED240-4S/740 DSM11 D9 MIO-CIO MB BGP235

BGP236 LED360-4S/740 DSM11 D9 MIO-CIO MB BGP236

BGP236 LED480-4S/740 DSM11 D9 MIO-CIO MB BGP236

BGP237 LED540-4S/740 DSM11 D9 MIO-CIO MB BGP237

BGP237 LED640-4S/740 DSM11 D9 MIO-CIO MB BGP237

BGP237 LED740-4S/740 DSM11 D9 MIO-CIO MB BGP23726 ’Type’ value description(s): ’BGP235’ = TubePoint GEN2 Small, ’BGP236’ = TubePoint GEN2 Medium, ’BGP237’ = TubePoint GEN2 Large

2019-02-21 More info available online at: www.lighting.philips.com data subject to change 5

16

'W

ed

ne

sday

20

thF

eb

rua

ry,2

01

9