10
SCALAMAX ® - Smart City Soluons MR-4859 Mulfuncon Actuator Document: DM15-3841 by For addional informaon, please contact us www.teslights.com - [email protected] Teslights Hybrid Lighng SCALAMAX Protocol Mulfuncon Actuator MR-4859 Data Sheet DM15-3841 March 2017 Document Number: DM15-3841 Copyright SCALAMAX, LLC 2007-2015 Compliant by MR-4859

TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

Teslights Hybrid Lighting SCALAMAX ProtocolMultifunction ActuatorMR-4859

Data Sheet DM15-3841March 2017

Document Number: DM15-3841Copyright SCALAMAX, LLC2007-2015

Compliant

by

MR-4859

Page 2: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

Page 2

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

Index

Warning

This guide is for persons who have received training and are qualified to work with electricity and electrical metering equipment. All applicable national and local electrical codes and standards must be followed. Failure to follow proper procedures may result in serious bodily harm including death.

Disclaimer

The information in this guide has been compiled with care, but Teslights Concepts Inc. makes no warranties as to the accuracy or completeness. Further, the products described herein may be changed or enhanced from time to time. This information does not constitute commitments or representations by Teslights Concepts Inc. and is subject to change without notice.

Images shown are a representation only. They may not match exactly with the real equipment.

Contact........................................................................................................................................................ 2

Warning....................................................................................................................................................... 2

Disclaimer................................................................................................................................................... 2

1. Introduction........................................................................................................................................... 3

1.1 MR-4859 Multifunction Actuator.................................................................................................. 3

1.2 MR-4859 Block Diagram.................................................................................................................. 4

1.3 Wiring.................................................................................................................................................... 5

2. Electrical Specifications....................................................................................................................... 7

3. Environment.......................................................................................................................................... 7

4. Dimensions Drawings.......................................................................................................................... 8

5. Certificaciones...................................................................................................................................... 9

6. Installations, cautions and warnings................................................................................................ 9

7. Product Limited Warranty.................................................................................................................. 9

8. Release dates......................................................................................................................................... 10

Page 3: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

Page 3

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

1. Introduction

The electric actuator MR-4859 is a device that allows control of:

• Four (4) output lines to command power contactors.• Three (3) “sniffer” inputs to supervise voltage on power lines (120…277VAC).• Three (3) voltage free digital inputs.• RS-485 MODBUS interface, with:

Bus termination resistor (ON/OFF selectable) Address selector for up to 63 addresses Possible Daisy Chain configuration of up to 63 actuators

The actuator has its own universal power supply (120…277VAC), so no external power adaptor is required for its operation.The MR-4859 can be connected directly to any SCALAMAX Gateway, which allows remote control of the actuator, and has all software functions built in.Two RS-485 interfaces allow easy daisy chain implementation with other actuators.In case the actuator is the last element in the daisy chain, a 120Ω resistor can terminate the RS-485 bus by means of a simple DIP-Switch, accessible from the terminal block area. Make sure only one (the last) actuator has the termination resistor enabled, otherwise, the RS-485 specifications won´t be met, resulting in erratic communication to other devices.The 4 positions of the “DIP-Switch” inside the actuator have the following functions:• Position 1-2-3 set the actuators´ address.• Position 4 of the actuator enables/disables the 120Ω termination resistor.

1.1 MR-4859 Multifunction Actuator

DIP-Switch: Address:

120

Resistor enabled Resistor disabled

12

34

ON

OFF 12 3

4ON

OFF

1 23

4ON

OFF

1 2 34

ON

OFF

12

34

ON

OFF

12

3 4ON

OFF

1 2 3 4ON

OFF

1 23 4

ON

OFF

12 3 4

ON

OFF

0

1

2

3

4

5

6

7

12 3

4ON

OFF

1 23

4ON

OFF

1 2 34

ON

OFF

12

34

ON

OFF

12

3 4ON

OFF

1 2 3 4ON

OFF

1 23 4

ON

OFF

12 3 4

ON

OFF

0

1

2

3

4

5

6

7

1 2 3 4ON

OFF1 2 3

4ON

OFF

termination resistor:

Page 4: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

Page 4

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

1.2 MR-4859 Block Diagram1.2 MR-4859 Block Diagram

MR-4859

A B RS-485

A B RS-485 Power

AC / DC

1 2 3 4ON

OFF

1 2 3 4 5 6 7 8 9

MR-4859

10 11 12 13 14 15 16 17 18

36 35 34 33 29 28 27 26 25 24 23 22 21 20 19

NI 5

84-

SR

TU

O 5

84-

SR

re

wo

P C

A

A B A B

1 T

UO

GID

2 T

UO

GID

3 T

UO

GID

1 NI

CA

2 NI

CA

3 NI

CA

4 NI

CA

1 NI

GID

2 NI

GID

3 NI

GID

Page 5: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

Page 5

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

1.3 Wiring

Power Supply

The MR-4859 has built in its own universal switched power supply, which allows powering the device with mains voltages from 120VAC up to 277VAC. It´s maximum power consumption is 8W. A PTC at the power input protects the circuit and components of the device.The AC mains power is wired to the terminal 36 and 35, and the earth/ground can be wired to terminal 27.

RS-485 communication port

RS-485 supports local networks and multidrop communications links, using differential balanced lines over twisted pair. It is generally accepted that RS-485 can be used with data rates up to 10 Mbit/s and distances up to 1,200 m (4,000 ft), but not at the same time. A rule of thumb is that the speed in bit/s multiplied by the length in meters should not exceed 108. Thus, a 50 meter cable should not signal faster than 2 Mbit/s.RS-485 drivers use three-state logic, allowing individual transmitters to be deactivated. This allows RS-485 to implement linear bus topologies using only two wires, connected to terminals 33/34 and 35/36 for both wires called A and B.Ideally, the two ends of the cable will have a termination resistor connected across the two wires.Without termination resistors, reflections of fast driver edges can cause data corruption.Termination resistors also reduce electrical noise sensitivity due to the lower impedance. The value of each termination resistor should be equal to the cable characteristic impedance (typically,120 ohms for twisted pairs).

Discrete AC Inputs (120…277VAC)

There are four discrete AC inputs called AC1, AC2, AC3 and AC4, allowing supervision of four line voltages. Enabling the feature to check if a circuit breaker of a specific line is open or closed. Terminals 1 and 2 for “AC IN 1”, 4 and 5 for “AC IN 2”, 7 and 8 for “AC IN 3”, and 10 and 11 for “AC IN 4”.

The equipment located along a set of RS-485 interchangeablywires are called nodes.

The arrangement of the wires is as a connected series of point-to-point nodes, known as multidrop wiring or circuits

HAZARD OF ELECTRIC SHOCK

• Disconnect all power from all equipment including connected devices prior to removing any covers o doors, or installing or removing any accessories, hardware, cables, or wires.• Always use a properly rated voltage sensing device to confirm the power is off where and when indicated.

Page 6: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

Page 6

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

Digital Inputs (potential free contacts)

In contrast to the discrete AC inputs, these three Digital Inputs are potential free, that is, only ON/OFF switches with NO voltages can be wired to these inputs. These three inputs are named “DIG IN 1” on terminal block 13 and 14, “DIG IN 2” on terminal block15 and 16, and “DIG IN 3” on terminal block 17 and 18.

Digital Outputs (potential free contacts)

These three digital outputs are standard relay outputs supplying no voltage. These are standard relay contacts withstanding up to 277VAC and a maximum of 2 A output current.The outputs are named “DIG OUT 1” on terminal blocks 19 and 20, “DIG OUT 2” on terminal blocks 22 and 23, and “DIG OUT 3” on terminal blocks 25 and 26.

Advice

Remember, electrical subcontractors are not always equipped with the appropriate tools for installing electronic devices. Smaller screwdrivers(#1) are required for securing wires in the terminal blocks, network crimp tools are important as well in case IP devices have to be connected, etc.Equally important are insulated cable-end sleeves as in DIN 46228 (part 4) for 1,5mm² and other wire gauges as shown below.Obviously, equally important are all other tools common to all electrical installers, such as strippers, other screwdrivers, cutters, electrical tape, and crimp tools to fasten insulated cable-end sleeves to the wire ends.

Page 7: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

Page 7

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

MR-4859

2. Electrical Specifications

Input Voltage (VAC):Frecuencia:Max. supply current:Power Factor:Max. power consumption:

100 ~ 277 VAC50 ~ 60Hz0,64 A (at 100VAC)> 0.858W

Power Supply

-25 ºC ~ 50ºC.-40 ºC ~ 75ºC.95 % without condensation or dripping water35 ºC

TC

3. Environment

The device has a protection degree of:

• IEC1 60529, IP-20 on terminal blocks, IP-40 on front panel.• Nema2, Type-12.• UL94-V0

1. International Electrotechnical Commission, 3 Rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland2. National Electrical Manufacturers Association, 1300 North 17th Street, Rosslyn, VA 22209

Ambient air temperature for operation:Ambient air temperature for storage:Relative humidity:TC:

Page 8: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

Page 8

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

4. Dimensions Drawings

• Dimensions: 90mm H x 106,5mm W x 56mm D• Wheight: 210 g• Color: Gray RAL 7035

• Mounting on: 35 mm/1.38 in. DIN Rail

45

35

3524

27

15

7.51

1

R1.2 R0.8

h2h3

t2

18

17.5

44t4 máx.

+0.5

-0.5

-0-0.5

W

HMR-4859

26 26

90

Dimensions 1 2 3

H2 max 45 55 75

H3 max. 45 55 75

Ampere Max 25 A Max 63 A Max 100 A

T2 max. 55 70 92,5

T4 min. 52 52 52

T4 máx. T2 max T2 max T2 maxNorme EN 60715 / Standard EN 60715

Norme DIN 438883 / Standard DIN 43880

Page 9: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

Page 9

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

6. Installations, cautions and warnings

• Do not install if the device is damaged. Inspect the box for obvious defects such as cracks in the housing.• This device doesn’t have replaceable or interchangeable elements, so it mustn’t be manipulated.• If the device is installed or used in a manner not specified by the accompanying documents, the safety of the device may be

impaired.• If the device functions abnormally, proceed with caution. The safety of the device may be impaired.• Do not install around combustible gas or gas vapor.• Do not install in an electrical service with current or voltage outside of the specified limit of the device.• Do not operate this device with the cover removed.• Beware of working around this device when the voltage is live. There is a risk of electric shock.• Check that all connections are reliable and correct before connecting the device to the voltage line.• See instructions for connection diagrams.

5. Certifications

2006/95/CE EN60950-1: 2006+A11: 2009EN60529_ 1991+A1: 2000

2004/108/CE

EN55022:2006+A1:2007EN55024: 1998+A1:2001+A2:2003EN61000-3-2:2006EN61000-3-3: 2008EN61547: 1995+A1: 2000TGN17

UL 916, 4 Edition, 2010-06-04FCC CFR47 PART 15 SUBPART BICES-003 ISSUE 5

Teslights, LCC warrants its equipment for 2 years from the ship date against defects in material or workmanship when installed in accordance with manufacturer’s instructions by qualified personnel.

This warranty does not cover installation, removal, reinstallation or labor costs and excludes normal wear and tear. The warranty does not cover product which has been altered from its original manufactured condition due to faulty installation, tampering, accident, neglect, abuse, force majeure or abnormal conditions of operation.

Obligation under this warranty is limited to repair and/or replacement, at Teslights, LLC option, of the manufactured product and in no event shall Teslights, LLC be liable for consequential or incidental damages.

7. Product Limited Warranty

Page 10: TS Multifunction Actuator MR-4859 en · 2017. 5. 5. · P G C A A B A B 1 T U O I D 2 U O I D 3 U O I D 1 N N I G C A ... RS-485 supports local networks and multidrop communications

Page 10

SCALAMAX® - Smart City SolutionsMR-4859 Multifunction ActuatorDocument: DM15-3841

by

For additional information, please contact uswww.teslights.com - [email protected]

8. Release dates

Manual Revision No. Release Date(dd/mm/yyyy)

MR-4859 R3413 12/09/2015