8
TrueZONE ® for Hydronic Control Wiring Diagrams

TrueZONE for Hydronic Controlrelay panel Z o n e 1 T (R) T (W ) HZ322 zone panel controlling a zone valve or circulator relay panel. Remove the Rh/Rc jumper on the equipment terminals

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TrueZONE for Hydronic Controlrelay panel Z o n e 1 T (R) T (W ) HZ322 zone panel controlling a zone valve or circulator relay panel. Remove the Rh/Rc jumper on the equipment terminals

TrueZONE® for Hydronic ControlWiring Diagrams

Page 2: TrueZONE for Hydronic Controlrelay panel Z o n e 1 T (R) T (W ) HZ322 zone panel controlling a zone valve or circulator relay panel. Remove the Rh/Rc jumper on the equipment terminals

2

Hot Water Zone Valve or Circulator Relay Panel Control

TrueZONE HZ322 with Hot Water Zone Valve or Circulator Relay Panel ...................................................................4

Hot Water Zone Valves with A/C Dampers

TrueZONE HZ311 with Hot Water Zone Valves and A/C Dampers ...........................................................................4

TrueZONE HZ432 with Hot Water Zone Valves and A/C Dampers ...........................................................................4

Hot Water Zone Valve or Circulator Relay Panel with A/C Dampers

TrueZONE HZ311 with Hot Water Zone Valve or Circulator Relay Panel and A/C Dampers .....................................5

TrueZONE HZ322 with Hot Water Zone Valve or Circulator Relay Panel and A/C Dampers .....................................5

TrueZONE HZ432 with Hot Water Zone Valve or Circulator Relay Panel and A/C Dampers .....................................5

Hydro-air Applications

TrueZONE HZ311 with Hydro-air Application ............................................................................................................6

TrueZONE HZ322 with Hydro-air Application ............................................................................................................6

Honeywell’s TrueZONE® panels can control zone valves and circulator

relays in hydronic heating applications. This document provides helpful

wiring diagrams to assist you in a variety of installation scenarios.

HZ311 HZ322 HZ432

Page 3: TrueZONE for Hydronic Controlrelay panel Z o n e 1 T (R) T (W ) HZ322 zone panel controlling a zone valve or circulator relay panel. Remove the Rh/Rc jumper on the equipment terminals

3

Wireless Zone Valve Control

Wireless TrueZONE HZ322 with Hot Water Zone Valve control .................................................................................6

Wireless TrueZONE HZ432 with Hot Water Zone Valve control .................................................................................6

Wireless Circulator Control

Wireless TrueZONE HZ322 with Hot Water Circulator control ...................................................................................7

Wireless TrueZONE HZ432 with Hot Water Circulator control ...................................................................................7

Wireless Relay Panel Control

Wireless TrueZONE HZ432 with Hot Water Relay Panels .........................................................................................7

When used with our RedLINK-enabled TrueZONE® panels, our Wireless

Adapter and Wireless FocusPRO® Thermostat you can easily – and

wirelessly – add hydronic zoning to a home or add more zones to an

existing system. In addition, wireless hydronic zoning introduces the

opportunity to increase profit with add-on accessories such as the

Portable Comfort Control and Wireless Outdoor Sensor – for the ultimate

in convenience and control.

TM

Wireless FocusPRO Thermostats TrueZONE Panel Wireless Adapter

+

Portable Comfort Control

Optional Wireless Accessories

Wireless Outdoor Sensor

Page 4: TrueZONE for Hydronic Controlrelay panel Z o n e 1 T (R) T (W ) HZ322 zone panel controlling a zone valve or circulator relay panel. Remove the Rh/Rc jumper on the equipment terminals

4

Hot Water Zone Valve or Circulator Relay Panel Control

RHRC

W1/EW2Y1Y2GOB

DS/BK

HZ322

HEAT 1HEAT 2COOL 1COOL 2

FANPURGE

EM HEAT

ZONE 1

ZONE 2

ZONE 3

EMERGENCYHEAT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

SE

NS

OR

DATSDATS

EQ

UIP

ME

NT

RC

PO

WE

R

M1M4M6

RC

W1/EW2Y1Y2G

O/BL

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

Zone 1 Thermostat

Power-closedSpring-open

ARD or ZD Damper

Wire zones 1-2 the same as zone 3.

Rc

WG

YR

h

Zone valve or circulator relay panel

Zo

ne

1 T

( R

)

T

( W

)

HZ322 zone panel controlling a zone valve or circulator relay panel.

Remove the Rh/Rc jumper on the equipment terminals of the HZ322

C7735A1000

Fan Relay

Compressor Relay

Cooling Transformer

C

RL1

L2

24 volt transformer

TrueZONE HZ322 with Hot Water Zone Valve or Circulator Relay Panel

Hot Water Zone Valves with A/C Dampers

There are different ways to wire zone valves to the aquastat. For complete wiring instructions on any of the zone valve and aquastat refer to the product data sheets for those controls.

M1M4M6RCWYG

M1M4M6RCWYG

M1M4M6RCWYG

RhRcWYG

RC

DATSDATS

PURGE OVERRIDE

HZ311

HEATCOOLFAN

PURGE

ZONE 1ZONE 2ZONE 3

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

EQ

UIP

ME

NT

PO

WE

RS

EN

SO

R

Zone 1 Thermostat

Rc

WG

YR

h

Power-closedSpring-open

ARD or ZD Damper

Th T

r

Wire zones 2 and 3 the same as zone 1.

(Yellow wires)Compressor Relay

Fan Relay

Cooling Transformer

The thermostats used must have separate Rh andRc (or R and Rc) terminals with jumper removed.

C7735A1000

HZ311 zone panel controlling air-conditioning zoned with dampers and heating zoned with hot water zone valves.

V8043 zone valve

24 volt transformer CR

L1 L2

C

RL1

L2

24 volt transformer

TrueZONE HZ311 with Hot Water Zone Valves and A/C Dampers

HZ432 zone panel controlling air-conditioning zoned with dampers and heating zoned with hot water zone valves.

HZ432

HEAT 1HEAT 2HEAT 3COOL 1COOL 2PURGE

FANEM HEAT

ZONE 1

ZONE 2

ZONE 3

ZONE 4

EMERGENCYHEAT

M1M4M6

RC

W1/EW2W3Y1Y2G

O/BL

M1M4M6RCW1/EW2W3Y1Y2GO/BL

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

M1M4M6RC

W1/EW2W3Y1Y2G

O/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2W3Y1Y2GO/BL

RC

PO

WE

RA

CC

ES

SO

RIE

S

AZ1AZ2

OTOT

SE

NS

OR

S

DATSDATS

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

Zo

ne

4D

AM

PE

RT

HE

RM

OS

TA

TR

F P

OR

T

RHRC

W1/EW2W3Y1Y2GOB

DS/BK

EQ

UIP

ME

NT

HOMECONFIG

CHECK OUT

ADJUST SETTING

C7735A1000

Fan Relay

Compressor Relay

Cooling Transformer

Power-closedSpring-open

ARD or ZD Damper

Zone 1 Thermostat

Rc

WG

YR

h

Th

Tr(Yellow wires)

V8043 zone valve

*There are different ways to wire zone valves to the aquastat. For complete wiring instructions on any of the zone valve and aquastat refer to the product data sheets for those controls.

Wire zones 2 -4 the same as zone 1.

The thermostats used must have separate Rh and Rc (or R and Rc) terminals with jumper removed.

C

RL1

L2

24 volt transformer

C R

L1L2

24 volt transformer

TrueZONE HZ432 with Hot Water Zone Valves and A/C Dampers

Page 5: TrueZONE for Hydronic Controlrelay panel Z o n e 1 T (R) T (W ) HZ322 zone panel controlling a zone valve or circulator relay panel. Remove the Rh/Rc jumper on the equipment terminals

5

Hot Water Zone Valve or Circulator Relay Panel with A/C Dampers

M1M4M6RCWYG

M1M4M6RCWYG

M1M4M6RCWYG

RhRcWYG

RC

DATSDATS

PURGE OVERRIDE

HZ311

HEATCOOLFAN

PURGE

ZONE 1ZONE 2ZONE 3

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

EQ

UIP

ME

NT

PO

WE

RS

EN

SO

R

Zone 1 Thermostat

Rc

WG

YR

h

Power-closedSpring-open

ARD or ZD Damper

Compressor Relay

Fan Relay

Cooling Transformer

C7735A1000

HZ311 zone panel controlling air-conditioning zoned with dampers and heating zoned with a zone valve or circulator relay panel.

M1M4M6RCWYG

M1M4M6RCWYG

M1M4M6RCWYG

RhRcWYG

RC

DATSDATS

PURGE OVERRIDE

HZ311

HEATCOOLFAN

PURGE

ZONE 1ZONE 2ZONE 3

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

Zo

ne

2D

AM

PE

RT

HE

RM

OS

TA

T

EQ

UIP

ME

NT

PO

WE

RS

EN

SO

R

ARD or ZD Damper

Wire zones 2 and 3 the same as zone 1.

Thermostats need to be configured to energize fan in heat.

C7735A1000

HZ311 zone panel controlling a hydro-air application * Remove the Rh/Rc jumper on the equipment terminals of the HZ311

Wire zones 2 and 3 the same as zone 1.

The thermostats used must have separate Rh and Rc (or R and Rc) terminals with jumper removed.

Zone valve or circulator relay panel

Zo

ne 1

T ( R

) T ( W

)

Aquastat

T (

R )

T (

W )

Fan relay center

G

Y

R

Zone 3 Thermostat

Rc

WG

YR

h

*

C

RL1

L2

24 volt transformer

C

RL1

L2

24 volt transformer

TrueZONE HZ311 with Hot Water Zone Valve or Circulator Relay Panel

and A/C Dampers

HZ432

HEAT 1HEAT 2HEAT 3COOL 1COOL 2PURGE

FANEM HEAT

ZONE 1

ZONE 2

ZONE 3

ZONE 4

EMERGENCYHEAT

M1M4M6

RC

W1/EW2W3Y1Y2G

O/BL

M1M4M6RCW1/EW2W3Y1Y2GO/BL

Zo

ne 3

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RC

W1/EW2W3Y1Y2G

O/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2W3Y1Y2GO/BL

RC

PO

WE

RA

CC

ES

SO

RIE

S

AZ1AZ2

OTOT

SE

NS

OR

S

DATSDATS

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

Zo

ne

4D

AM

PE

RT

HE

RM

OS

TA

TR

F P

OR

T

RHRC

W1/EW2W3Y1Y2GOB

DS/BK

EQ

UIP

ME

NT

HOMECONFIG

CHECK OUT

ADJUST SETTING

HZ432 zone panel controlling air-conditioning zoned with dampers and heating zoned with a zone valve or circulator relay panel.

Wire zones 2 and 3 the same as zone 1.

The thermostats used must have separate Rh and Rc (or R and Rc) terminals with jumper removed.

C7735A1000

Fan Relay

Compressor Relay

Cooling Transformer

Power-closedSpring-open

ARD or ZD Damper

Zone 1 Thermostat

Rc

WG

YR

h

Zone valve or circulator relay panel

Zon

e 1

T ( R

) T ( W

)

C

RL1

L2

24 volt transformer

TrueZONE HZ432 with Hot Water Zone Valve or Circulator Relay Panel

and A/C Dampers

RHRC

W1/EW2Y1Y2GOB

DS/BK

HZ322

HEAT 1HEAT 2COOL 1COOL 2

FANPURGE

EM HEAT

ZONE 1

ZONE 2

ZONE 3

EMERGENCYHEAT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

SE

NS

OR

DATSDATS

EQ

UIP

ME

NT

RC

PO

WE

R

M1M4M6

RC

W1/EW2Y1Y2G

O/BL

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

HZ322 zone panel controlling air-conditioning zoned with dampers and heating zoned with a zone valve or circulator relay panel.

Wire zones 2 and 3 the same as zone 1.

The thermostats used must have separate Rh and Rc (or R and Rc) terminals with jumper removed.

C7735A1000

Fan Relay

Compressor Relay

Cooling Transformer

Power-closedSpring-open

ARD or ZD Damper

Zone 1 Thermostat

Rc

WG

YR

h

Zone valve or circulator relay panel

Zo

ne 1

T ( R

) T ( W

)

C

RL1

L2

24 volt transformer

TrueZONE HZ322 with Hot Water Zone Valve or Circulator Relay Panel

and A/C Dampers

Page 6: TrueZONE for Hydronic Controlrelay panel Z o n e 1 T (R) T (W ) HZ322 zone panel controlling a zone valve or circulator relay panel. Remove the Rh/Rc jumper on the equipment terminals

6

M1M4M6RCWYG

M1M4M6RCWYG

M1M4M6RCWYG

RhRcWYG

RC

DATSDATS

PURGE OVERRIDE

HZ311

HEATCOOLFAN

PURGE

ZONE 1ZONE 2ZONE 3

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

EQ

UIP

ME

NT

PO

WE

RS

EN

SO

R

Zone 1 Thermostat

Rc

WG

YR

h

Power-closedSpring-open

ARD or ZD Damper

Compressor Relay

Fan Relay

Cooling Transformer

C7735A1000

HZ311 zone panel controlling air-conditioning zoned with dampers and heating zoned with a zone valve or circulator relay panel.

M1M4M6RCWYG

M1M4M6RCWYG

M1M4M6RCWYG

RhRcWYG

RC

DATSDATS

PURGE OVERRIDE

HZ311

HEATCOOLFAN

PURGE

ZONE 1ZONE 2ZONE 3

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

Zo

ne

2D

AM

PE

RT

HE

RM

OS

TA

T

EQ

UIP

ME

NT

PO

WE

RS

EN

SO

RARD or ZD Damper

Wire zones 2 and 3 the same as zone 1.

Thermostats need to be configured to energize fan in heat.

C7735A1000

HZ311 zone panel controlling a hydro-air application * Remove the Rh/Rc jumper on the equipment terminals of the HZ311

Wire zones 2 and 3 the same as zone 1.

The thermostats used must have separate Rh and Rc (or R and Rc) terminals with jumper removed.

Zone valve or circulator relay panel

Zo

ne 1

T ( R

) T ( W

)

Aquastat

T (

R )

T (

W )

Fan relay center

G

Y

R

Zone 3 Thermostat

Rc

WG

YR

h

*

C

RL1

L2

24 volt transformer

C

RL1

L2

24 volt transformer

Hydro-air Applications

TrueZONE HZ311 with Hydro-air Application

Wireless Zone Valve Control

ABCD

THM4000R

RHRC

W1/EW2Y1Y2GOB

DS/BK

HZ322

HEAT 1HEAT 2COOL 1COOL 2

FANPURGE

EM HEAT

ZONE 1

ZONE 2

ZONE 3

EMERGENCYHEAT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

SE

NS

OR

DATSDATS

EQ

UIP

ME

NT

RC

PO

WE

R

M1M4M6

RC

W1/EW2Y1Y2G

O/BL

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

ABCDW

IRE

LE

SS

WIRELESSHOME

CONFIGCHECK OUT MODE

BACK NEXTADJUST SETTING

Wireless HZ322 zone panel controlling zone valves.

Transformer

Remove the Rh/Rc jumper at the panel.

C7735A1000

TH

TR

End sw

itch

V8043 zone valve(or equivalent)

Fan center

C

R

If the Honeywell valve has yellow and red wires instead of terminal connections, the red wires are the end switch, the yellow wires are the TH and TR.

C

G

Y

R

Outdoor condenser

TH

TR

End

sw

itch

TH

TR

End

sw

itch

Wire the end switch from each valve in parallel to the R and W or T and T at the aquastat or boiler.

D

D

C

B

A

A

If cooling is zoned, the dampers (not shown), are wired as normal to the Truezone panel.

B

C

B

B

C

Wireless adaptor*

Parts needed:1. Wireless Truezone panels: (Verify the box has a Redlink sticker on it)HZ322K - 3-zones, 2 heat/2 cool.

2. Wireless thermostats with adaptor for zone 1: Option 1: YTH6320R1023 is a kit that includes a TH6320R wireless programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.Option 2: YTH5320R1025 is a kit that includes a TH5320R wireless non-programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.

3. Wireless thermostats without adaptor for zones 2-3: Option 1: TH6320R1004 - Wireless programmable thermostat without adaptor.Option 2: TH5320R1002 – Wireless non- programmable thermostat without adaptor.

Accessories: (optional)REM5000R1001 - Remote Controller (Can control up to 16 thermostats)C7089R1013 - Wireless Outdoor Sensor.

Aquastat

T(R

) T

(W)

Wireless TrueZONE HZ322 with Hot Water Zone Valve control

HZ432

HEAT 1HEAT 2HEAT 3COOL 1COOL 2PURGE

FANEM HEAT

ZONE 1

ZONE 2

ZONE 3

ZONE 4

EMERGENCYHEAT

M1M4M6

RC

W1/EW2W3Y1Y2G

O/BL

M1M4M6RCW1/EW2W3Y1Y2GO/BL

Zo

ne 3

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RC

W1/EW2W3Y1Y2G

O/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2W3Y1Y2GO/BL

RC

PO

WE

RA

CC

ES

SO

RIE

S

AZ1AZ2

OTOT

SE

NS

OR

S

DATSDATS

Zo

ne

1D

AM

PE

RT

HE

RM

OS

TA

T

Zo

ne

4D

AM

PE

RT

HE

RM

OS

TA

T

RHRC

W1/EW2W3Y1Y2GOB

DS/BK

EQ

UIP

ME

NT

HOMECONFIG

CHECK OUT

ADJUST SETTING

ABCDW

IRE

LE

SS

ABCD

THM4000R

Wireless HZ432 zone panel controlling zone valves.

Transformer

Remove the Rh/Rc jumper at the panel.

Aquastat

T(R

) T

(W)

C7735A1000

TH

TR

End sw

itch

V8043 zone valve(or equivalent)

Fan center

C

R

If the Honeywell valve has yellow and red wires instead of terminal connections, the red wires are the end switch, the yellow wires are the TH and TR.

C

G

Y

R

Outdoor condenser

TH

TR

End

sw

itch

TH

TR

End

sw

itch

Wire the end switch from each valve in parallel to the R and W or T and T at the aquastat or boiler.

D

D

C

B

A

A

If cooling is zoned, the dampers (not shown), are wired as normal to the Truezone panel.

B

B

C

B

C

Wireless adaptor*

Parts needed:1. Wireless Truezone panel: (Verify the box has a Redlink sticker on it)HZ432K - 4-zones, 3 heat/2 cool. 2. Wireless thermostats with adaptor for zone 1: Option 1: YTH6320R1023 is a kit that includes a TH6320R wireless programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.Option 2: YTH5320R1025 is a kit that includes a TH5320R wireless non-programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.3. Wireless thermostats without adaptor for zones 2-4: Option 1: TH6320R1004 - Wireless programmable thermostat without adaptor.Option 2: TH5320R1002 – Wireless non- programmable thermostat without adaptor.

Accessories: (optional)REM5000R1001 - Remote Controller (Can control up to 16 thermostats)C7089R1013 - Wireless Outdoor Sensor.

E When a THM4000R is used you cannot expand beyond 4 zones.

E

TH

TR

End

sw

itch

B

C

Wireless TrueZONE HZ432 with Hot Water Zone Valve control

RHRC

W1/EW2Y1Y2GOB

DS/BK

HZ322

HEAT 1HEAT 2COOL 1COOL 2

FANPURGE

EM HEAT

ZONE 1

ZONE 2

ZONE 3

EMERGENCYHEAT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

SE

NS

OR

DATSDATS

EQ

UIP

ME

NT

RC

PO

WE

R

M1M4M6

RC

W1/EW2Y1Y2G

O/BL

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

HZ322 zone panel controlling a hydro-air application.

ARD or ZD Damper

Wire zones 2-3 the same as zone 1.

Zone panel needs to be configured to energize fan in heat.

R

C

L1

L2

Transformer

* Remove the Rh/Rc jumper on the equipment terminals of the HZ322

Aquastat

T (

R )

T (

W )

Fan relay center

G

Y

R

Zone 3 Thermostat

Rc

WG

YR

h

*

C7735A1000

TrueZONE HZ322 with Hydro-air Application

Remove the Rh/Rc jumper at the panel.

If the Honeywell valve has yellow and red wires instead of terminal connections, the red wires are the end switch, the yellow wires are the TH and TR.

Wire the end switch from each valve in parallel to the R and W or T and T at the aquastat or boiler.

If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZONE panel.

See parts needed section on page 7.

D

C

B

A

Remove the Rh/Rc jumper at the panel.

If the Honeywell valve has yellow and red wires instead of terminal connections, the red wires are the end switch, the yellow wires are the TH and TR.

Wire the end switch from each valve in parallel to the R and W or T and T at the aquastat or boiler.

If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZONE panel.

When a THM4000R is used you cannot expand beyond 4 zones.

See parts needed section on page 7.

D

C

B

A

E

Page 7: TrueZONE for Hydronic Controlrelay panel Z o n e 1 T (R) T (W ) HZ322 zone panel controlling a zone valve or circulator relay panel. Remove the Rh/Rc jumper on the equipment terminals

7

14

36

14

36

1 4

3 6

ABCD

THM4000R

RHRC

W1/EW2Y1Y2GOB

DS/BK

HZ322

HEAT 1HEAT 2COOL 1COOL 2

FANPURGE

EM HEAT

ZONE 1

ZONE 2

ZONE 3

EMERGENCYHEAT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2Y1Y2GO/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

SE

NS

OR

DATSDATS

EQ

UIP

ME

NT

RC

PO

WE

R

M1M4M6

RC

W1/EW2Y1Y2G

O/BL

Zo

ne

3D

AM

PE

RT

HE

RM

OS

TA

T

ABCDW

IRE

LE

SS

WIRELESSHOME

CONFIGCHECK OUT MODE

BACK NEXTADJUST SETTING

Wireless HZ322 zone panel controlling circulators.

Transformer

Remove the Rh/Rc jumper at the panel.

C7735A1000

R8222D1014Fan center

C

R

Wire the 1 and 3 from each relay in parallel to the T and T (or R and W) terminals at the boiler or aquastat.

C

G

Y

R

Outdoorcondenser

C

C

B

A

A

If cooling is zoned, the dampers (not shown), are wired as normal to the Truezone panel.

Wireless adaptor*

Parts needed:1. Wireless Truezone panels: (Verify the box has a Redlink sticker on it)HZ322K - 3-zones, 2 heat/2 cool.

2. Wireless thermostats with adaptor for zone 1: Option 1: YTH6320R1023 is a kit that includes a TH6320R wireless programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.Option 2: YTH5320R1025 is a kit that includes a TH5320R wireless non-programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.

3. Wireless thermostats without adaptor for zones 2-3: Option 1: TH6320R1004 - Wireless programmable thermostat without adaptor.Option 2: TH5320R1002 – Wireless non- programmable thermostat without adaptor.

4. R8222D1014 relays (or other relay with low volt coil, and line volt rated double-pole normally-open switches)

Accessories: (optional)REM5000R1001 - Remote Controller (Can control up to 16 thermostats)C7089R1013 - Wireless Outdoor Sensor.

Circulator

It is up to the installing contractor to determine what voltage is required to power the transformer primary and circulators.

Line Voltage power

Aquastat

T(R

) T(W

)

D

E Each circulator circuit would be wired to the corresponding zone’s relay. This circuit is shown on zone 3 of this diagram.

B

C D E

C D E

L2

L1

Wireless Circulator Control

Wireless TrueZONE HZ322 with Hot Water Circulator control

Wireless Relay Panel Control

Wireless TrueZONE HZ432 with Hot Water Circulator control

14

36

14

36

14

361 4

3 6

Wireless HZ432 zone panel controlling circulators.

Remove the Rh/Rc jumper at the panel.

Wire the 1 and 3 from each relay in parallel to the T and T (or R and W) terminals at the boiler or aquastat.

Outdoor condenser

C

B

A

If cooling is zoned, the dampers (not shown), are wired as normal to the Truezone panel.

Parts needed:1. Wireless Truezone panels: (Verify the box has a Redlink sticker on it)HZ432K - 4-zones, 3 heat/2 cool.2. Wireless thermostats with adaptor for zone 1: Option 1: YTH6320R1023 is a kit that includes a TH6320R wireless programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.Option 2: YTH5320R1025 is a kit that includes a TH5320R wireless non-programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.3. Wireless thermostats without adaptor for zones 2-3: Option 1: TH6320R1004 - Wireless programmable thermostat without adaptor.Option 2: TH5320R1002 – Wireless non- programmable thermostat without adaptor.4. R8222D1014 relays (or other relay with low volt coil, and line volt rated double-pole normally-open switches)

Accessories: (optional)REM5000R1001 - Remote Controller (Can control up to 16 thermostats)C7089R1013 - Wireless Outdoor Sensor.

Circulator

It is up to the installing contractor to determine what voltage is required to power the transformer primary and circulators.

Aquastat

T(R

) T(W

)

D

E Each circulator circuit would be wired to the corresponding zone’s relay. This circuit is shown on zone 4 of this diagram.

B

ABCD

THM4000R

HZ432

HEAT 1HEAT 2HEAT 3COOL 1COOL 2PURGE

FANEM HEAT

ZONE 1

ZONE 2

ZONE 3

ZONE 4

EMERGENCYHEAT

M1M4M6

RC

W1/EW2W3Y1Y2G

O/BL

M1M4M6RCW1/EW2W3Y1Y2GO/BL

Zo

ne 3

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RC

W1/EW2W3Y1Y2G

O/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2W3Y1Y2GO/BL

RC

PO

WE

RA

CC

ES

SO

RIE

S

AZ1AZ2

OTOT

SE

NS

OR

S

DATSDATS

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

Zo

ne

4D

AM

PE

RT

HE

RM

OS

TA

T

RHRC

W1/EW2W3Y1Y2GOB

DS/BK

EQ

UIP

ME

NT

HOMECONFIG

CHECK OUT

ADJUST SETTING

ABCDW

IRE

LE

SS

C

G

Y

R

A

Wireless adaptor*

F

C7735A1000

TransformerC

R

L2

L1

Fan center

Line Voltage power

F When a THM4000R is used you cannot expand beyond 4 zones.

C D E

C D E

C D E

C

1

3

Zone 1 of relay panel

T(R

)

T(W

)

C

1

3

Zone 3 of relay panel

T(R

)

T(W

)

C

1

3

Zone 2 of relay panel

T(R

)

T(W

)

C

1

3

Wireless HZ432 zone panel controlling a hot water relay panel.

Remove the Rh/Rc jumper at the panel.

Outdoor condenser

C

B

A

If cooling is zoned, the dampers (not shown), are wired as normal to the Truezone panel.

Parts needed:1. Wireless Truezone panels: (Verify the box has a Redlink sticker on it)HZ432K - 4-zones, 3 heat/2 cool.2. Wireless thermostats with adaptor for zone 1: Option 1: YTH6320R1023 is a kit that includes a TH6320R wireless programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.Option 2: YTH5320R1025 is a kit that includes a TH5320R wireless non-programmable thermostat, and THM4000R1000 wireless adaptor. You would need 1 of these per zone panel.3. Wireless thermostats without adaptor for zones 2-3: Option 1: TH6320R1004 - Wireless programmable thermostat without adaptor.Option 2: TH5320R1002 – Wireless non- programmable thermostat without adaptor.4. R8222B1067 relays (or other relay with low volt coil, and low-voltage rated normally-open switches)

Accessories: (optional)REM5000R1001 - Remote Controller (Can control up to 16 thermostats)C7089R1013 - Wireless Outdoor Sensor.

It is up to the installing contractor to determine what voltage is required to power the transformer primary and circulators.

Zone 4 of relay panel

T(R

) T(W

)

ABCD

THM4000R

HZ432

HEAT 1HEAT 2HEAT 3COOL 1COOL 2PURGE

FANEM HEAT

ZONE 1

ZONE 2

ZONE 3

ZONE 4

EMERGENCYHEAT

M1M4M6

RC

W1/EW2W3Y1Y2G

O/BL

M1M4M6RCW1/EW2W3Y1Y2GO/BL

Zo

ne 3

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RC

W1/EW2W3Y1Y2G

O/BL

Zo

ne 2

DA

MP

ER

TH

ER

MO

ST

AT

M1M4M6RCW1/EW2W3Y1Y2GO/BL

RC

PO

WE

RA

CC

ES

SO

RIE

S

AZ1AZ2

OTOT

SE

NS

OR

S

DATSDATS

Zo

ne 1

DA

MP

ER

TH

ER

MO

ST

AT

Zo

ne

4D

AM

PE

RT

HE

RM

OS

TA

T

RHRC

W1/EW2W3Y1Y2GOB

DS/BK

EQ

UIP

ME

NT

HOMECONFIG

CHECK OUT

ADJUST SETTING

ABCDW

IRE

LE

SS

C

G

Y

R

A

Wireless adaptor*

F

C7735A1000

TransformerC

R

L2

L1

Fan center

Line Voltage power

D When a THM4000R is used you cannot expand beyond 4 zones.

C

B

Wireless TrueZONE HZ432 with Hot Water Relay Panels

Remove the Rh/Rc jumper at the panel.

It is up to the installing contractor to determine what voltage is required to power the transformer primary and circulators.

If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZONE panel.

Wire the 1 and 3 from each relay in parallel to the T and T (or R and W) terminals at the boiler or aquastat.

Each circulator circuit would be wired to the corresponding zone’s relay. This circuit is shown on zone 3 of this diagram.

See parts needed section on page 7.

D

C

B

A

ERemove the Rh/Rc jumper at the panel.

It is up to the installing contractor to determine what voltage is required to power the transformer primary and circulators.

If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZONE panel.

Wire the 1 and 3 from each relay in parallel to the T and T (or R and W) terminals at the boiler or aquastat.

Each circulator circuit would be wired to the corresponding zone’s relay. This circuit is shown on zone 4 of this diagram.

When a THM4000R is used you cannot expand beyond 4 zones.

See parts needed section on page 7.

D

C

B

A

E

F

Remove the Rh/Rc jumper at the panel.

It is up to the installing contractor to determine what voltage is required to power the transformer primary and circulators.

If cooling is zoned, the dampers (not shown), are wired as normal to the TrueZONE panel.

When a THM4000R is used you cannot expand beyond 4 zones.

See parts needed section on page 7.

D

C

B

A

Parts needed for wireless installation:

Verify the TrueZONE box has a RedLINK sticker on it.

Wireless Zoning Adaptor Kit: You would need 1 of these per zone panel

Programmable Wireless Zoning Adaptor Kit (YTH6320R1023)

Non-Programmable Wireless Zoning Adaptor Kit (YTH5320R1025)

*Wireless Adaptor (THM4000R): Connects to your choice of wireless thermostats

Programmable Wireless FocusPRO (TH6320R1004)

Non-Programmable Wireless FocusPRO (TH5320R1002)

Optional Wireless Accessories:

Portable Comfort Control (REM5000R1001)

Wireless Outdoor Sensor (C7089R1013)

TM

Page 8: TrueZONE for Hydronic Controlrelay panel Z o n e 1 T (R) T (W ) HZ322 zone panel controlling a zone valve or circulator relay panel. Remove the Rh/Rc jumper on the equipment terminals

8

Automation and Control Solutions

In the US:

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422-3992

In Canada:

Honeywell Limited

35 Dynamic Drive

Toronto, Ontario M1V 4Z9

customer.honeywell.com

67-7219 PRFebruary 2009© 2009 Honeywell International Inc.

Illustrated in this paper are the most common wiring diagrams for hydronic

application of the TrueZONE® control panel. It is the contractor's choice on

what options make most sense for their business and customer. With the

introduction of wireless hydronic zoning, this document will help create new

installation solutions, as well as opportunity to earn more profit with add-on

wireless accessories.

For questions, please contact the Honeywell Zoning Hotline toll-free at

1-800-828-8367