24
TRX-PS-BU Series Trinix Backup Power Supplies Installation Manual 071 8443 00 September 22, 2005

Trinix Backup Power Supplies Installation Manual - Grass Valley

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Trinix Backup Power Supplies Installation Manual - Grass Valley

TRX-PS-BU SeriesTrinix Backup Power Supplies

Installation Manual

071 8443 00September 22, 2005

Page 2: Trinix Backup Power Supplies Installation Manual - Grass Valley

2 TRX-PS-BU Series Installation Manual

Contacting Grass Valley

Copyright © Grass Valley Inc. All rights reserved.

Grass Valley Web Site The www.thomsongrassvalley.com web site offers the following:

Online User Documentation — Current versions of product catalogs, brochures, data sheets, ordering guides, planning guides, manuals, and release notes in .pdf format can be downloaded.

FAQ Database — Solutions to problems and troubleshooting efforts can be found by searching our Frequently Asked Questions (FAQ) database.

Software Downloads — Software updates, drivers, and patches can be down-loaded.

Region Voice Fax Address Web Site

North America (800) 547-8949

Support: (530) 478-4148

Sales: (530) 478-3347

Support: (530) 478-3181

Grass Valley400 Providence Mine Rd. P.O. Box 599000 Nevada City, CA 95959-7900 USA

www.thomsongrassvalley.com

Pacific Operations +852-2585-6688Support: 852-2585-6579

+852-2802-2996

U.K., Asia, Middle East +44 1753 218 777 +44 1753 218 757

France +33 1 45 29 73 00

Germany, Europe +49 6150 104 782 +49 6150 104 223

Page 3: Trinix Backup Power Supplies Installation Manual - Grass Valley

Contents

PrefaceAbout This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Additional Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Safety SummarySafety Terms and Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Terms in This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Terms on the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Symbols on the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Regulatory NoticesCertifications and Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

FCC Emission Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Canadian EMC Notice of Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10EN55022 Class A Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Canadian Certified Power Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Canadian Certified AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Laser Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Laser Safety Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Laser Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11FCC Emission Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Section 1 — IntroductionDV-33128. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15DV-33256. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16DV-33512. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Materials Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Equipment Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Software Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Section 2 — InstallationProcedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

TRX-PS-BU Series Installation Manual 3

Page 4: Trinix Backup Power Supplies Installation Manual - Grass Valley

Contents

Appendix A — SpecificationsMechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Environmental. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Air Intake/Exhaust Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Electrical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

4 TRX-PS-BU Series Installation Manual

Page 5: Trinix Backup Power Supplies Installation Manual - Grass Valley

TRX-PS-BU Series Installation Manual 5

Preface

About This ManualThis manual provides installation instructions for the Trinix backup power supplies.

Additional DocumentationTrinix Installation and Operating Manual, part no. 071 8276 xx. Includes planning and installation instructions.

A printed copy of the documentation set is normally provided with the system. Individual manuals may be ordered by contacting Technical Sup-port. For contact information, see page 2. Electronic copies of all routing products documentation are available on the following documentation CDs:

CD 071 8274 xx. Includes Jupiter VM-3000 and Jupiter CM-4000 man-uals.

CD 071 8130 xx. Includes Encore Control System manuals.

These documents are also available on our web site. See page 2.

Page 6: Trinix Backup Power Supplies Installation Manual - Grass Valley

Safety SummaryRead and follow the important safety information below, noting especially those instructions related to risk of fire, electric shock or injury to persons. Additional specific warnings not listed here may be found throughout the manual.

WARNING Any instructions in this manual that require opening the equipment cover or enclosure are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that con-tained in the operating instructions unless you are qualified to do so.

Safety Terms and Symbols

Terms in This ManualSafety-related statements may appear in this manual in the following form:

WARNING Warning statements identify conditions or practices that may result in per-sonal injury or loss of life.

CAUTION Caution statements identify conditions or practices that may result in damage to equipment or other property, or which may cause equipment crucial to your business environment to become temporarily non-operational.

Terms on the ProductThe following terms may appear on the product:

DANGER — A personal injury hazard is immediately accessible as you read the marking.

WARNING — A personal injury hazard exists but is not immediately acces-sible as you read the marking.

CAUTION — A hazard to property, product, and other equipment is present.

TRX-PS-BU Series Installation Manual 6

Page 7: Trinix Backup Power Supplies Installation Manual - Grass Valley

Safety Summary

Symbols on the ProductThe following symbols may appear on the product:

WarningsThe following warning statements identify conditions or practices that can result in personal injury or loss of life.

Dangerous voltage or current may be present — Disconnect power and remove battery (if applicable) before removing protective panels, soldering, or replacing components.

Do not service alone — Do not internally service this product unless another person capable of rendering first aid and resuscitation is present.

Remove jewelry — Prior to servicing, remove jewelry such as rings, watches, and other metallic objects.

Avoid exposed circuitry — Do not touch exposed connections, components or circuitry when power is present.

Indicates that dangerous high voltage is present within the equipment enclosure that may be of sufficient magnitude to constitute a risk of electric shock.

Indicates that user, operator or service technician should refer to product manual(s) for important operating, maintenance, or service instructions.

This is a prompt to note fuse rating when replacing fuse(s). The fuse referenced in the text must be replaced with one having the ratings indicated.

Identifies a protective grounding terminal which must be con-nected to earth ground prior to making any other equipment connections.

Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal.

Indicates that static sensitive components are present which may be damaged by electrostatic discharge. Use anti-static procedures, equipment and surfaces during servicing.

7 TRX-PS-BU Series Installation Manual

Page 8: Trinix Backup Power Supplies Installation Manual - Grass Valley

— Safety Summary

Use proper power cord — Use only the power cord supplied or specified for this product.

Ground product — Connect the grounding conductor of the power cord to earth ground.

Operate only with covers and enclosure panels in place — Do not operate this product when covers or enclosure panels are removed.

Use correct fuse — Use only the fuse type and rating specified for this product.

Use only in dry environment — Do not operate in wet or damp conditions.

Use only in non-explosive environment — Do not operate this product in an explosive atmosphere.

High leakage current may be present — Earth connection of product is essential before connecting power.

Dual power supplies may be present — Be certain to plug each power supply cord into a separate branch circuit employing a separate service ground. Disconnect both power supply cords prior to servicing.

Double pole neutral fusing — Disconnect mains power prior to servicing.

Use proper lift points — Do not use door latches to lift or move equipment.

Avoid mechanical hazards — Allow all rotating devices to come to a stop before servicing.

CautionsThe following caution statements identify conditions or practices that can result in damage to equipment or other property

Use correct power source — Do not operate this product from a power source that applies more than the voltage specified for the product.

Use correct voltage setting — If this product lacks auto-ranging power sup-plies, before applying power ensure that the each power supply is set to match the power source.

Provide proper ventilation — To prevent product overheating, provide equip-ment ventilation in accordance with installation instructions.

Use anti-static procedures — Static sensitive components are present which may be damaged by electrostatic discharge. Use anti-static procedures, equipment and surfaces during servicing.

8 TRX-PS-BU Series Installation Manual

Page 9: Trinix Backup Power Supplies Installation Manual - Grass Valley

Safety Summary

Do not operate with suspected equipment failure — If you suspect product damage or equipment failure, have the equipment inspected by qualified service personnel.

Ensure mains disconnect — If mains switch is not provided, the power cord(s) of this equipment provide the means of disconnection. The socket outlet must be installed near the equipment and must be easily accessible. Verify that all mains power is disconnected before installing or removing power supplies and/or options.

Route cable properly — Route power cords and other cables so that they ar not likely to be damaged. Properly support heavy cable bundles to avoid con-nector damage.

Use correct power supply cords — Power cords for this equipment, if provided, meet all North American electrical codes. Operation of this equipment at voltages exceeding 130 VAC requires power supply cords which comply with NEMA configurations. International power cords, if provided, have the approval of the country of use.

Use correct replacement battery — This product may contain batteries. To reduce the risk of explosion, check polarity and replace only with the same or equivalent type recommended by manufacturer. Dispose of used bat-teries according to the manufacturer’s instructions.

Troubleshoot only to board level — Circuit boards in this product are densely populated with surface mount technology (SMT) components and applica-tion specific integrated circuits (ASICS). As a result, circuit board repair at the component level is very difficult in the field, if not impossible. For war-ranty compliance, do not troubleshoot systems beyond the board level.

9 TRX-PS-BU Series Installation Manual

Page 10: Trinix Backup Power Supplies Installation Manual - Grass Valley

Regulatory Notices

Certifications and Compliances

FCC Emission ControlThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equip-ment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equip-ment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Grass Valley Group can affect emission compliance and could void the user’s authority to operate this equipment.

Canadian EMC Notice of ComplianceThis digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regula-tions of the Canadian Department of Communications.

Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux appareils numeriques de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par le ministère des Communications du Canada.

EN55022 Class A WarningFor products that comply with Class A. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

TRX-PS-BU Series Installation Manual 10

Page 11: Trinix Backup Power Supplies Installation Manual - Grass Valley

Regulatory Notices

Canadian Certified Power CordsCanadian approval includes the products and power cords appropriate for use in the North America power network. All other power cords supplied are approved for the country of use.

Canadian Certified AC AdapterCanadian approval includes the AC adapters appropriate for use in the North America power network. All other AC adapters supplied are approved for the country of use.

Laser Compliance

Laser Safety RequirementsThe device used in this product is a Class 1 certified laser product. Oper-ating this product outside specifications or altering from its original design may result in hazardous radiation exposure, and may be considered an act of modifying or new manufacturing of a laser product under U.S. regula-tions contained in 21CFR Chapter1, subchapter J or CENELEC regulations in HD 482 S1. People performing such an act are required by law to recertify and reidentify this product in accordance with provisions of 21CFR sub-chapter J for distribution within the U.S.A., and in accordance with CENELEC HD 482 S1 for distribution within countries using the IEC 825 standard.

Laser SafetyLaser safety in the United States is regulated by the Center for Devices and Radiological Health (CDRH). The laser safety regulations are published in the “Laser Product Performance Standard,” Code of Federal Regulation (CFR), Title 21, Subchapter J.

The international Electrotechnical Commission (IEC) Standard 825, “Radi-ation of Laser Products, Equipment Classification, Requirements and User’s Guide,” governs laser products outside the United States. Europe and member nations of the European Free trade Association fall under the jurisdiction of the Comite European de Normalization Electrotechnique (CENELEC).

For the CDRH: The radiant power is detected trough a 7 mm aperture at a distance of 200 mm from the source focused through a lens with a focal length of 100 mm.

For IEC compliance: The radiant power is detected trough a 7 mm aperture at a distance of 100 mm from the source focused through a lens with a focal length of 100 mm.

11 TRX-PS-BU Series Installation Manual

Page 12: Trinix Backup Power Supplies Installation Manual - Grass Valley

Regulatory Notices

FCC Emission LimitsThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may no cause harmful inter-ference, and (2) this device must accept any interference received, including interference that may cause undesirable operation. This device has been tested and found to comply with FCC Part 15 Class B limits for a digital device when tested with a representative laser-based fiber optical system that complies with ANSI X3T11 Fiber Channel Standard.

Certification

Category Standard Designed/tested for compliance with:

Safety UL1950 Safety of Information Technology Equipment, including Electrical Business Equipment (Second edition, 1993).

IEC 950 Safety of Information Technology Equipment, including Electrical Business Equipment (Second edition, 1991).

CAN/CSA C22.2, No. 950-93 Safety of Information Technology Equipment, including Electrical Business Equipment.

EN60950 Safety of Information Technology Equipment, including Electrical Business Equipment.

TRX-PS-BU Series Installation Manual 12

Page 13: Trinix Backup Power Supplies Installation Manual - Grass Valley

Certifications and Compliances

TRX-PS-BU Series Installation Manual 13

Page 14: Trinix Backup Power Supplies Installation Manual - Grass Valley

Figure 1. TRX-PS-BU Trinix Backup Power Supplies

OR

OR

OR

DV-33128

DV-33256

DV-33512

TRX-PS-BU1200

TRX-PS-BU2400

TRX-PS-BU2400

TRX-PS-BU3600

TRX-PS-BU2400TRX-PS-BU2400

TRX-PS-BU3600TRX-PS-BU3600

14 TRX-PS-BU Series Installation Manual

Page 15: Trinix Backup Power Supplies Installation Manual - Grass Valley

Section 1Introduction

The TRX-PS-BU series of products are designed to supplement the Trinix DV-33128, DV-33256 and DV-33512 internal power supplies to provide increased backup protection.. Three packages are available:

• TRX-PS-BU1200 - 1 ea. 1200 watt module mounted in a 1 RU frame

• TRX-PS-BU2400 - 2 ea. 1200 watt modules mounted in a 1 RU frame

• TRX-PS-BU3600 - 3 ea. 1200 watt modules mounted in a 1 RU frame

Each module consists of a Unipower TPCP 7000 1200 watt power supply. The rack frame is a Unipower TPCP R1U3-B 1.75-inch chassis.

As shown on the facing page, these packages can be used in various com-binations with Trinix DV-33128, DV-33256, and DV-33512 routers.

The power supplies are essentially bussed together so that the power load is shared at all times. If one supply fails, the remaining supplies on that bus will continue to provide power. The failed supply should be replaced as soon as possible.

DV-33128For DV-33128 routers, installation of one TRX-PS-BU1200 will provide a total of three on-line power supplies: two internally-mounted supplies and one supply mounted in the external chassis. Any one of these three sup-plies can fully power the DV-33128 router.

Installation of one TRX-PS-BU2400 will provide a total of four on-line power supplies: two internally-mounted supplies and two supplies mounted in the external chassis. Any one of these four supplies can fully power the DV-33128 router.

TRX-PS-BU Series Installation Manual 15

Page 16: Trinix Backup Power Supplies Installation Manual - Grass Valley

Section 1 — Introduction

DV-33256For DV-33256 routers, installation of one TRX-PS-BU2400 will provide a total of four on-line power supplies: two internally-mounted supplies and two supplies mounted in the external chassis. Any one of these four sup-plies can fully power the DV-33256 router.

Installation of one TRX-PS-BU3600 will provide a total of five on-line power supplies: two internally-mounted supplies and three supplies mounted in the external chassis. Any one of these five supplies can fully power the DV-33256 router.

DV-33512For DV-33512 routers, installation of two TRX-PS-BU2400s will provide a total of eight on-line power supplies divided into two groups:

• One group consists of internal supplies A and B and the two supplies in one of the external chassis (total of four supplies). The four supplies in this group power half the boards in the router. Any one of the four supplies can provide all needed power to these boards.

• The opposite group consists of internal supplies C and D and the two supplies in the other external chassis (total of four supplies). The four supplies in this group power half the boards in the router. Any one of the five supplies can provide all needed power to these boards

Installation of two TRX-PS-BU3600s will provide a total of ten on-line power supplies divided into two groups:

• One group consists of internal supplies A and B and the three supplies in one of the external chassis (total of five supplies). The five supplies in this group power half the boards in the router. Any one of the five supplies can provide all needed power to these boards.

• The opposite group consists of internal supplies C and D and the three supplies in the other external chassis (total of five supplies). The five supplies in this group power half the boards in the router. Any one of the five supplies can provide all needed power to these boards.

16 TRX-PS-BU Series Installation Manual

Page 17: Trinix Backup Power Supplies Installation Manual - Grass Valley

Specifications

Materials SuppliedEach of the three packages includes the following:

Qty Description

1 Power cable assembly, power supply rack to Trinix, 9 ft.1, 2, or 3 AC mains power cord kit (type varies per destination country)1, 2, or 3 Power supply, Unipower TPCP 7000, 1200 W 48 VDC

1 Power supply rack, Unipower TPCP R1U3-B1 or 2 Blank panels for power supply rack

2 Small pattern 6 nut2 Split lock no. 6 washer2 4-40 x 1/4 SEMS screw4 6-32 x 1/4 SEMS screw2 1/4-20 UNC nut2 Internal lock washer2 No. 6 flat washer

Equipment RequiredTRX-PS-BU1200 installations:

1.75 in. (1 RU) rack space in Trinix or adjacent rack, and1 AC power outlet, 1200 watts.

TRX-PS-BU2400 installations:

1.75 in. (1 RU) rack space in Trinix or adjacent rack, and2 AC power outlets, 1200 W each (total 2400 W)

TRX-PS-BU3600 installations:

1.75 in. (1 RU) rack space in Trinix or adjacent rack, and3 AC power outlets, 1200 W each (total 3600 W)

Software RequiredNo software changes are needed.

SpecificationsFor mechanical, environmental, and electrical specifications, see Appendix A - Specifications.

TRX-PS-BU Series Installation Manual 17

Page 18: Trinix Backup Power Supplies Installation Manual - Grass Valley

Section 1 — Introduction

Ordering InformationTable 1.

TRX-PS-BU1200 POWER SUPPLY 1200 W 1 RU STAND ALONE DC OUTPUT

TRX-PS-BU2400 POWER SUPPLY 2400 W 1 RU STAND ALONE DC OUTPUT

TRX-PS-BU3600 POWER SUPPLY 3600 W 1 RU STAND ALONE DC OUTPUT

18 TRX-PS-BU Series Installation Manual

Page 19: Trinix Backup Power Supplies Installation Manual - Grass Valley

Ordering Information

TRX-PS-BU Series Installation Manual 19

Page 20: Trinix Backup Power Supplies Installation Manual - Grass Valley
Figure 2. TRX-PS-BU Trinix Backup Power Supplies

Table 2. DC power cord pinouts.

Trinix DC Input connector Cable description

(Ground) Yellow/green

Plain black

DC IN + (left) 1 (red)

DC IN + (right) 2 (blue)

DC IN - (left) 3 (white)

DC IN - (right) 4 (yellow)

129-160INPUTS

DC INPUT

DC IN -DC IN +

42 - 54 VDC30-24 AMPS

INPUTS

33-641-32INPUTS INPUTS

PS B

PS B

225-256193-224129-160 161-19265-9633-64 97-1281-3297-12865-96OUTPUTS

WARNING: FOR CONTINUED PROTECTION

WITH SAME TYPE AND RATING OF FUSE115: 12.5A 250V SLOW BLOW230: T6.3A 240V

AGAINST RISK OF FIRE, REPLACE ONLY

OUTPUTS

AUTO SELECT100-130V/200-240V10.0A/5.0A47-63HZ

INPUTSINPUTS

PS A

OUTPUTS OUTPUTS

PS A

OUTPUTS

OUTPUTS

OUTPUTS OUTPUTSOUTPUTS

OP EXPANDVIT REDUNDANT

60Hz ENABLEINT XPT CNTL

IN EXPAND CONTROL

MONOPOP

MON

193-224161-192 225-256

ALARM

INPUTS

INPUTS

INPUTS INPUTS

CROSSPOINT BUS

CONSOLE

GPIO/TC

CONSOLEB

4

3

2

1

A

PRIMARY

INREF

INREF

COM BUS4 2

NIC B

SECONDARY

3 1

COM BUS

NIC A

5

879 6

ABC

0

0

34

8

0

31

79

2

56

4

01 2

LEVELSUPER

MONITOR

512384

128256 14

1211

10

1315

14

1211

10

131532

64488096

9611280

16324864

16

112ULTRA

FRAME

L

E

N L

E

N

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

31

30

29

28

5

8

9

11

26

25

27

7

6

22

24

23

4

3

2

21

20

1

15

14

13

12

10

19

16

17

18

32

DC INPUT

DC IN -DC IN +

42 - 54 VDC30-24 AMPS

PS B PS A

DC INPUT

DC IN -DC IN +

42 - 54 VDC30-24 AMPS

PS D PS C

289 - 320INPUTS

449 - 480OUTPUTS

161 - 192OUTPUTS353 - 384

B

A

B

A

B

A

B

1

4

3

2

MONOP

A

INPUTS129 - 160

OUTPUTSINPUTS

417 - 448OUTPUTS

225 - 256INPUTS

193 - 224INPUTSINPUTS

385 - 416OUTPUTS

289 - 320OUTPUTS

321 - 352OUTPUTS

481 - 512OUTPUTS

257 - 288OUTPUTS

DC IN + DC IN -

30 - 24 AMPS

DC IN +

30 - 24 AMPS

DC IN -

42 - 54 VDCDC INPUT 2 NOT FUSED

DC INPUT 1 NOT FUSED42 - 54 VDC

1

2

4

3

INREF

INPUTS

353 - 384INPUTS

321 - 352INPUTS

257 - 288INPUTS

1024512

20481536

16112 115

804864

8048

64

0ULTRA

MONITOR

1632 96112

35

4121113

3

65

2

4

8

1413

1211

108

0

7

1

9

15

FRAME

610 79

LEVEL

32SUPER0

96 20

14

CBA

INT XPT CNTL

OUTPUT EXPANDINPUT EXPAND

60Hz ENABLE

SYNC REDUNDANT

PS IFC FAN IFC

XPT BUS

COM BUSCOM BUSALARM

CONTROL

CONSOLE B

CONSOLE A

AGAINST RISK OF FIRE, REPLACE ONLYWITH SAME TYPE AND RATING OF FUSE

WARNING: FOR CONTINUED PROTECTION

AC INPUT: 100-240 V ~, 10.0-5.0A, 50-60Hz

PS D

DC IN -DC IN +

100-120V: 12.5A, 250V, SLO BLO200-240V: T6.3A, 250V

30 - 24 AMPS42 - 54 VDCDC INPUT 2

30 - 24 AMPS42 - 54 VDC

DC OUT -DC OUT +

DC OUTPUT 2

AC INPUT: 100-240 V ~, 10.0-5.0A, 50-60Hz100-120V: 12.5A, 250V, SLO BLO

200-240V: T6.3A, 250V

FRAME IFC

NIC B

NIC A

COM BUS

COM BUS

XPT BUS

SECONDARY

PRIMARY

DC IN -DC IN +

30 - 24 AMPS42 - 54 VDCDC INPUT 1

42 - 54 VDC30 - 24 AMPS

DC OUT + DC OUT -

DC OUTPUT 1

PS C PS A

3

1

PS B

GPIO/TC

REF IN4

REF IN2

L

E

N

L

E

NL

E

N

L

E

N

DV-33128

DV-33256

DV-33512

Yellow/green

Plainblack

Red

Blue

White Yellow

Yellow/green

Plainblack

Red

Blue

White Yellow

TRX-PS-BU Series Installation Manual 20

Page 21: Trinix Backup Power Supplies Installation Manual - Grass Valley

Section 2Installation

ProcedureThe following procedure will not disrupt normal operation of the router.

1. Install the supplied TPCP R1U3-B power supply frame(s).

The frames are shipped with the DC cables already connected.

The power supply frames should preferably be mounted in the same equipment rack as the Trinix, but they may be mounted in an adjacent rack if necessary. The cables provided for connection to the Trinix are approximately nine feet (2.7 m) long.

No special ventilation spacing is needed for these frames since the airflow is from front to back.

2. Connect the DC power cable(s) to the Trinix rear panel DC Input connector(s).

See Table 2 for pinout information.

3. Connect the supplied AC power cords.

All LEDs on the front of the power supply array(s) should now be green.The left LED of each supply monitors AC; the right LED monitors DC.

4. Check the DC voltage now being provided at the Trinix “DC In” connector(s). Voltage should be between 47.0 and 48.5 VDC.

5. At an appropriate time, check the fail-over function of the new supplies.This procedure should not cause any interruption to router operation; however, Grass Valley recommends that you perform this check when the consequences of possible signal interruption are at a minimum.

• For DV-33128 and DV-33256 units, pull both internal power sup-plies out a few inches. The router should remain powered up. Push the internal supplies back into position.

• For DV-33512 units, first make sure that both power supply frames are installed and powered on per the above procedure. Open the main chassis door. Open the power supply chassis and pull the A and B supplies out a few inches. The router should remain powered up. Replace the A and B supplies. Pull the C and D supplies; the router should remain powered. Replace the C and D supplies.

TRX-PS-BU Series Installation Manual 21

Page 22: Trinix Backup Power Supplies Installation Manual - Grass Valley

Section 2 — Installation

6. This completes the installation.

22 TRX-PS-BU Series Installation Manual

Page 23: Trinix Backup Power Supplies Installation Manual - Grass Valley

Appendix ASpecifications

Mechanical

Environmental

Air Intake/Exhaust Locations

All modules draw cooling air through fans in the front. Warm air is exhausted through openings in the back. It is not necessary to leave open space above or below the chassis.

Table 3. Mechanical Specifications

Depth, a

a Allow a minimum of 6 in. (152 mm) of clear space at the rear of the MCP for proper cable clearance and air flow.

Width Height Weight b

b All weights approximate.

Rack Units

TRX-PS-BU1200 11.56 in. / 294 mm 19.0 in. / 483 mm 1.75 in. / 44 mm 7.2 lb. / 3.2 kg 1

TRX-PS-BU2400 11.56 in. / 294 mm 19.0 in. / 483 mm 1.75 in. / 44 mm 10.3 lb. / 4.6 kg 1

TRX-PS-BU3600 11.56 in. / 294 mm 19.0 in. / 483 mm 1.75 in. / 44 mm 13.5 lb. / 6.1 kg 1

Table 4.

Environmental Characteristics (operation with required forced air cooling)

Operating temperature 32 to 158 degrees F (0 to 70 degrees C) ambient

Full specifications met 32 to 122 degrees F (0 to 50 degrees C)

Storage temperature -40 to 185 F (-40 to +85 degrees C)

TRX-PS-BU Series Installation Manual 23

Page 24: Trinix Backup Power Supplies Installation Manual - Grass Valley

Appendix A — Specifications

Electrical Table 5.

Total Output Power, Continuous, Max 800 - 1200 watts per module

Input voltage range 85 - 264 VAC

Input frequency 47 - 63 Hz

Hot-swap operation Yes

24 TRX-PS-BU Series Installation Manual