Upload
ishmael-zamora
View
32
Download
2
Tags:
Embed Size (px)
DESCRIPTION
Trigger simulation for 2004-2005. Trigger data quality Calorimeter trigger threshold calibration DC trigger threshold calibration. LNF, 1 Feb 2006 M.Palutan and B.Sciascia for the Trigger group. Trigger data quality critical issues: - PowerPoint PPT Presentation
Citation preview
Trigger simulation for 2004-2005
LNF, 1 Feb 2006M.Palutan and B.Sciascia for the Trigger group
• Trigger data quality• Calorimeter trigger threshold calibration• DC trigger threshold calibration
Trigger data quality
critical issues:
• hardware errors from TORTA board CALO trigger information in the decision board is not compatible with what observed at the sector’s level• bad RF signal from DAFNE some clocks are lost by the RF/4-T1 sinch. chain wrong event-t0, bad calo time resolution.• missing veto at injection (not critical, possibly higher bkg)
results:• list of “bad” runs
Summary: All runs 2004 2005
N-A NOT-reco reco (nb-1) (nb-1) (nb-1)-------------------------------------------------------------------------------------------------
Torta-bad OR (t0-bad>0.01%) 101 18250 9157
NO-inj-veto 0 755 11980
NO physmon info 48 3024 12580
• Updated run list ready
Rejected
DB2 flag(No-INJ)
Data quality vs run number
Bad trigger conditions No PHYSMON info
20042005
20042005
20042005
20042005Not-Reco Not-Reco
RecoReco
Calorimeter trigger threshold calibration
Control samples:
• Kcrash+autoTRG + KS 00 (“photons”) + KS + (“pions”)• Single sector threshold evaluation for data and MC• 2004-2005 data set divided in 20 periods of about 100 pb-1
according to main HW interventions and machine stops.
Results:• Comparison of Data and MC photon thresholds MC thr settings (already in DB2).
Photons on the barrel (before calibration)
data
MC data/MCZ(cm)
Th
(MeV
)T
h(M
eV)
Z(cm)
5%
5%
Photons on the barrel (after calibration)
Data
MC data/MCZ(cm)
Th
(MeV
)T
h(M
eV)
Z(cm)
Photons on the EndCaps (after calibration)
dataMC
data/MC
Y(cm)
Th
(MeV
)T
h(M
eV)
Y(cm)
Th
(MeV
)T
h(M
eV)
Y(cm)
Y(cm)
Photon trigger sector multiplicity
Barrel
East
West
dataMC
<
Pion trigger sector multiplicity
Barrel
East
West
dataMC
MC efficiency spread for a +/- 5% overall threshold drift
Ke3
K3
0
0
KS00
KL decay
0.5%
MC efficiency spread for a +/- 5% overall threshold drift
KS+-
KL decay
0
0
Ke3
K3
1%
Cosmic veto barrel multiplicity
Barrel BarreldataMC
Photons Pions
DC trigger threshold calibration
Control sample:
• Kcrash+autoTRG + KS +
• DC trigger efficiency on events triggered by CALO, evaluated on Data and MC.• 2004-2005 data set divided in 20 periods of about 100 pb-1
according to main HW interventions and machine stops.
Results:• Comparison of Data and MC DC trigger efficiency MC DC2 thr settings (already in DB2).
DC2 EfficiencyDC2 Efficiency
Data period
20042005
70 75 80 85
DC2thr
1 DC2thr 0.5 %
DataDC2 efficiency vs data taking periods
MCDC2 efficiency scan vs threshold applied in MC
Spares
TORTA hardware errors
Bad RF/4
Injection veto
Summary (RUN_NR 36 904, 30/05/05)
N-A NOT-reco reco # of run (nb-1) (nb-1) (nb-1)-------------------------------------------------------------------------------------------------
NO phystrig info 102 4416 14750 194
Torta-bad OR (t0-bad>0.1%) 101 17270 2193 121 …+ (t0-bad>0.01%) 0. 843 6308 36
… + NO-inj-veto 0. 633 11050 83 • Run list ready
Data quality vs run number
Bad trigger conditions No PHYSMON info