22
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. © Kawneer Company, Inc., 2013 kawneer.com EC 97911-110 Trifab TM 451UT Framing System 1 AUGUST, 2016 ADMC060EN Features • Trifab TM 451UT is 4-1/2" (114.3) deep with a 2" (50.8) sightline • Center Plane glass applications • Flush glazed from either the inside or outside • Screw Spline fabrication • Dual IsoLock TM lanced and debridged thermal break Infill options up to 1-1/8" (28.6) thickness High performance sill flashing • Permanodic TM anodized finishes in seven choices Painted finishes in standard and custom choices Optional Features • Acoustical rating per AAMA 1801 and ASTM E 1425 Project specific U-factors (See Thermal Charts) • Integrates with Versoleil TM SunShade Outrigger System and Horizontal Single Blade System Product Applications • Storefront, Ribbon Window or Punched Openings • Single-span • Integrated entrance framing allowing Kawneer standard entrances or other specialty entrances to be incorporated Kawneer windows, GLASSvent TM UT windows are easily incorporated For specific product applications, Consult your Kawneer representative.

Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Embed Size (px)

Citation preview

Page 1: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

TrifabTM 451UT Framing System 1AUGUST, 2016

ADMC060EN

Features• TrifabTM 451UT is 4-1/2" (114.3) deep with a 2" (50.8) sightline• Center Plane glass applications• Flush glazed from either the inside or outside• Screw Spline fabrication• Dual IsoLockTM lanced and debridged thermal break• Infill options up to 1-1/8" (28.6) thickness• High performance sill flashing• PermanodicTM anodized finishes in seven choices• Painted finishes in standard and custom choices

Optional Features• Acoustical rating per AAMA 1801 and ASTM E 1425• Project specific U-factors (See Thermal Charts)• Integrates with VersoleilTM SunShade Outrigger System and Horizontal Single Blade System

Product Applications• Storefront, Ribbon Window or Punched Openings• Single-span• Integrated entrance framing allowing Kawneer standard entrances or other specialty entrances

to be incorporated• Kawneer windows, GLASSvent TM UT windows are easily incorporated

For specific product applications,Consult your Kawneer representative.

Page 2: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

TrifabTM 451UT Framing System2 AUGUST, 2016

ADMC060EN

BLANK PAGE

Page 3: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

TrifabTM 451UT Framing System 3AUGUST, 2016

ADMC060EN

BASIC FRAMING DETAILS (CENTER - Outside Glazed) .................4BASIC FRAMING DETAILS (CENTER - Inside Glazed) ....................5MISCELLANEOUS FRAMING (CENTER) ..........................................6CURVING & TRIM DETAILS ...............................................................7AATM 250/425 THERMAL ENTRANCE DETAILS ...............................8GLASSvent TM UT WINDOW DETAILS ................................................98225TL THERMAL WINDOW DETAILS ...........................................10WINDLOAD / DEADLOAD CHARTS ..........................................11-14THERMAL CHARTS ................................................................... 15-21

INDEX (CENTER)

LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.

Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted.

The following metric (SI ) units are found in these details: m – meter cm – centimeter mm – millimeter s – second Pa – pascal MPa – megapascal

Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement.

Page 4: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

1

4

2

3

5

452TCG001

452TCG126

(50.

8)2"

(114.3)

4-1/2"

452TCG014451CG004

452TCG037

(114.3)

4-1/2"

1/2"

2"(1

2.7)

(50.

8)

452TCG021451CG004

(50.

8)2"

(114

.3)

4-1/

2"

(50.8)2"

452TCG126

452TCG001

451TCG002

452TCG001

(50.8)2"

TrifabTM 451UT Framing System4 AUGUST, 2016

ADMC060EN

ELEVATION IS NUMBER KEYED TO DETAILSDUAL IsoLockTM THERMAL BREAK

SCREW SPLINE

4JAMB

5VERTICAL

1HEAD

2HORIZONTAL

3SILL

SCALE 3" = 1'-0"

BASIC FRAMING DETAILS (CENTER - Outside Glazed)

Page 5: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

1

4

2

3

5

452TCG014451CG004

452TCG037

(114.3)

4-1/2"

1/2"

2"(1

2.7)

(50.

8)

(114

.3)

4-1/

2"

(50.8)2"

452TCG126

452TCG001

451TCG002

452TCG001

(50.8)2"

451CG004452TCG003

452TCG126

(50.

8)2"

(114.3)

4-1/2"

451CG004452TCG011

2"(5

0.8)

TrifabTM 451UT Framing System 5AUGUST, 2016

ADMC060EN

ELEVATION IS NUMBER KEYED TO DETAILS

SCREW SPLINE

SCALE 3" = 1'-0"

BASIC FRAMING DETAILS (CENTER - Inside Glazed)

DUAL IsoLockTM THERMAL BREAK

4JAMB

5VERTICAL

1HEAD

2HORIZONTAL

3SILL

Page 6: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

452TCG540452TCG010

400110

2-1/2"

(63.5)

452TCG540452TCG010

2-1/2"

(63.5)

451TCG002

452TCG012

(50.8)2"

451TCG002

452TCG013

2"(50.8)

451TCG002

452TCG112

450110

2-1/4"

(57.2)

452UTCG028

452UTCG034

452UTCG028

452UTCG028

452UTCG034

452UTCG028

TrifabTM 451UT Framing System6 AUGUST, 2016

ADMC060EN

SCALE 3" = 1'-0"

HEAVY WEIGHTMULLION

2-1/4" (57.2) MULLIONW/ STEEL

TUBULAREXPANSION MULLION

TUBULAREXPANSION MULLION

WITH OPTIONAL STEEL

MEDIUM WEIGHTMULLION

STEELREINFORCING

STEELREINFORCING

MISCELLANEOUS FRAMING (CENTER)

135° CORNER(THERMAL)

Page 7: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

175186 175188

175190

175191

175190

175187

175186

4-1/2"(114.3)

2"(5

0.8)

069271

1

2

3

1

2

3

451TVG150

451TVG150

451TVG150451TVG150

TrifabTM 451UT Framing System 7AUGUST, 2016

ADMC060EN

SCALE 3" = 1'-0"

STOOL TRIM CLIPWITH HIGH PERFORMANCE

FLASHING

CURVING DETAILS(Center Plane Only)

BRAKE METALADAPTOR AT VERTICAL

BRAKE METALADAPTOR AT HORIZONTAL

STOOL TRIMBRAKE METALFILLERS

BRAKE METALFILLERS

TYPICAL

TYP

ICA

L

CURVING & TRIM DETAILS

Seal over Stool Trim fasteners to prevent water infiltration.

Page 8: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

1

2

3

4 5 452TCG001

452TCG126

(50.

8)2"

(114.3)

4-1/2"

TrifabTM 451UT Framing System8 AUGUST, 2016

ADMC060EN

AATM 250/425 THERMAL ENTRANCE DETAILS

SCALE 3" = 1'-0"

ELEVATION IS NUMBER KEYED TO DETAILS.

TrifabTM VG 451T CENTER DOOR FRAMING SHOWN.OTHER FRAMING OPTIONS AVAILABLE.CONSULT YOUR KAWNEER REPRESENTATIVE.

NOTE: Butt Hung or Offset Pivot Doors Only.

AATM 250/425 THERMAL DOOR

4DOORJAMB

5MEETINGSTILES

1HEAD

2TRANSOM

BAR

3BOTTOM

RAIL

Page 9: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

1

2 3

5

7

6

4

8

452TCG001

452TCG126

469407

452TCG021

451CG004

469407

452TCG126

452TCG001

469407

451TCG002

452TCG001

469407451TCG002

452TCG001

469407

452TCG001

451TCG002469407

469407

452TCG014

451CG004

452TCG037

452TCG001

452TCG1261

2

3

4

5 76 8

TrifabTM 451UT Framing System 9AUGUST, 2016

ADMC060EN

ELEVATION IS NUMBER KEYED TO DETAILS

OUTSWING CASEMENTVERTICAL SECTION

OUTSWING CASEMENTHORIZONTAL SECTION

PROJECT-OUTHORIZONTAL SECTION

PROJECT-OUTVERTICAL SECTION

NOTE: Black spacer is recommended when 1" (25.4) insulating glass is used.

GLASSvent TM UT WINDOW DETAILS

SCALE 3" = 1'-0"TrifabTM 451UT FRAMING SHOWN.OTHER FRAMING OPTIONS AVAILABLE.CONSULT YOUR KAWNEER REPRESENTATIVE.

Page 10: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

1

3

2

4

451CG004 452TCG021

469407

451CG004

452TCG021

469407

452TCG001

451TCG002

469407

452TCG001

451TCG002469407

1

2

3 4

TrifabTM 451UT Framing System10 AUGUST, 2016

ADMC060EN

SCALE 3" = 1'-0"

ELEVATION IS NUMBER KEYED TO DETAILS

PROJECT-OUTVERTICAL SECTION

PROJECT-OUTHORIZONTAL SECTION

8225TL THERMAL WINDOWS SHOWNNOTE: OTHER VENT TYPES CAN BE

ACCOMMODATED, CONSULT YOUR KAWNEERREPRESENTATIVE FOR OTHER OPTIONS

8225TL THERMAL WINDOWS

Page 11: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

TrifabTM 451UT Framing System 11AUGUST, 2016

ADMC060EN

WIND LOAD CHARTSMullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. A conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information.

If the end reaction of the mullion [mullion spacing (ft.) times height (ft.) times specified wind load (psf) divided by two] is more than 500 lbs., the optional Mullion Anchors must be used. Consult Application Engineering. (Mullion Anchor not used with Lightweight Receptor.)

DEADLOAD CHARTSHorizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.35) thick glass supported on two setting blocks placed at the loading points shown.

WIND LOAD / DEADLOAD CHARTS

Page 12: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

452TCG010 / 452TCG540

87654321

A

4

5

6

7

8

9

10

11

12

13

14

15

B

CDE

1.0 2.0

4.0

3.0

2.0

15

14

13

12

11

10

9

8

7

6

5

41 2 3 4 5 6 7 8

2.01.0

4.0

3.0

2.0

A

BCD

E

87654321

A

4

5

6

7

8

9

10

11

12

13

14

15

BC

D

E

1.0 2.0

4.0

3.0

2.0

15

14

13

12

11

10

9

8

7

6

5

41 2 3 4 5 6 7 8

2.01.0

4.0

3.0

2.0

A

B

CDE

87654321

A

4

5

6

7

8

9

10

11

12

13

14

15

B

C

DE

1.0 2.0

4.0

3.0

2.0

15

14

13

12

11

10

9

8

7

6

5

41 2 3 4 5 6 7 8

2.01.0

4.0

3.0

2.0

A

BCDE

452TCG012

TrifabTM 451UT Framing System12 AUGUST, 2016

ADMC060EN

WITH HORIZONTALS WITHOUT HORIZONTALSWIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WITH HORIZONTALS WITHOUT HORIZONTALSWIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

SWITH HORIZONTALS WITHOUT HORIZONTALS

WIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WINDLOAD CHARTS

WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505

WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505

WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505

Allowable Stress Design Load

LRFD Ultimate Design Load

A = 15 PSF (720) 25 PSF (1200)B = 20 PSF (960) 33 PSF (1580)C = 25 PSF (1200) 42 PSF (2000)D = 30 PSF (1440) 50 PSF (2400)E = 40 PSF (1920) 67 PSF (3200)

Page 13: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

452TCG112

452TCG013

87654321

A

4

5

6

7

8

9

10

11

12

13

14

15

B

CD

E

1.0 2.0

4.0

3.0

2.0

15

14

13

12

11

10

9

8

7

6

5

41 2 3 4 5 6 7 8

2.01.0

4.0

3.0

2.0

A

BCD

E

87654321

A

4

5

6

7

8

9

10

11

12

13

14

15

B

CDE

1.0 2.0

4.0

3.0

2.0

15

14

13

12

11

10

9

8

7

6

41 2 3 4 5 6 7

5

8

2.01.0

4.0

3.0

2.0

ABCD

E

2.0

3.0

4.0

2.01.0

E

D

C

B

15

14

13

12

11

10

9

8

7

6

5

4

A

1 2 3 4 5 6 7 8

E

D

C

B

A

2.0

3.0

4.0

1.0 2.0

876543214

5

6

7

8

9

10

11

12

13

14

15

TrifabTM 451UT Framing System 13AUGUST, 2016

ADMC060EN

452TCG112with 450110 STEEL

WITH HORIZONTALS WITHOUT HORIZONTALSWIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WITH HORIZONTALS WITHOUT HORIZONTALSWIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WITH HORIZONTALS WITHOUT HORIZONTALSWIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WINDLOAD CHARTS

WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505

WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505

WINDLOAD CHARTS ARE BASED ON COMPOSITE PROPERTIES WHICH ARE CALCULATED IN ACCORDANCE WITH AAMA TIR-8 AND AAMA 505

Allowable Stress Design Load

LRFD Ultimate Design Load

A = 15 PSF (720) 25 PSF (1200)B = 20 PSF (960) 33 PSF (1580)C = 25 PSF (1200) 42 PSF (2000)D = 30 PSF (1440) 50 PSF (2400)E = 40 PSF (1920) 67 PSF (3200)

Page 14: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

87654321

A0

1

2

3

4

5

6

7

8

9

10

11

1.0 2.0

3.0

2.0

1.0

BC

87654321

A0

1

2

3

4

5

6

7

8

9

10

11

1.0 2.0

3.0

2.0

1.0

BC

452TCG021

452TCG011

TrifabTM 451UT Framing System14 AUGUST, 2016

ADMC060EN

A = (1/4 POINT LOADING)B = (1/6 POINT LOADING)C = (1/8 POINT LOADING)

WIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

WIDTH IN METERS

WIDTH IN FEET

HE

IGH

T IN

FE

ET

HE

IGH

T IN

ME

TER

S

DEADLOAD CHARTS

WITH HORIZONTALS

WITH HORIZONTALS

Page 15: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

7'-0

"

9'-6

"

15'-8"

5'-0"

2'-0

"

0.49

91%

0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20

75 7085 8095 90

0.80

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

TrifabTM 451UT Framing System 15AUGUST, 2016

ADMC060EN

Example Glass U-factor = 0.42 Btu/hr·ft2·oF

Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135ft2

Total Projected Area = (Total Daylight Opening + Total Area of Framing System) = 15'-8" x 9'-6" = 148.83ft2

Percent of Glass = (Total Daylight Opening ÷ Total Projected Area) = (135 ÷ 148.83)100 = 91%

System U-factor vs Percent of Glass Area

EXAMPLE

Percent of GlassBased on 91% glass and center of glass (COG) U-factor of 0.42System U-factor is equal to 0.49 Btu/hr x ft2 x oF

COGU-factor

THERMAL CHARTS

Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines)

Page 16: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

0,48 (2,73)

0,46 (2,61)

0,44 (2,50)

0,42 (2,39)

0,40 (2,27)

0,38 (2,16)

0,36 (2,05)

0,34 (1,93)

0,32 (1,82)

0,30 (1,71)

0,28 (1,59)

0,26 (1,48)

0,24 (1,37)

0,22 (1,25)

0,20 (1,14)

TrifabTM 451UT Framing System16 AUGUST, 2016

ADMC060EN

THERMAL CHARTS

Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507.

System U-Factor for Vision Glass

COG U-factor

Vision Area / Total Area (%)

Syst

em U

-Fac

tor (

Btu

/h·ft

2 ·°F)

Page 17: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

TrifabTM 451UT Framing System 17AUGUST, 2016

ADMC060EN

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision AreaCOG

SHGC

COG VT

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Area / Total Area (%)

Vision Ares / Total Area (%)

Syst

em S

HG

C

Charts are generated per AAMA 507.

Charts are generated per AAMA 507.

Syst

em V

T

Page 18: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

TrifabTM 451UT Framing System18 AUGUST, 2016

ADMC060EN

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

TrifabTM 451UT Thermal Transmittance 1 (BTU/hr • ft 2 • °F)Glass U-Factor 3 Overall U-Factor 4

0.48 0.520.46 0.510.44 0.490.42 0.480.40 0.460.38 0.440.36 0.430.34 0.410.32 0.390.30 0.380.28 0.360.26 0.350.24 0.330.22 0.310.20 0.30

SHGC Matrix 2

Glass SHGC 3 Overall SHGC 4

0.75 0.660.70 0.620.65 0.580.60 0.530.55 0.490.50 0.450.45 0.400.40 0.360.35 0.310.30 0.270.25 0.230.20 0.180.15 0.140.10 0.090.05 0.05

Visible Transmittance 2

Glass VT 3 Overall VT 4

0.75 0,660.70 0,610.65 0,570.60 0,530.55 0,480.50 0,440.45 0,390.40 0,350.35 0,310.30 0,260.25 0,220.20 0,180.15 0,130.10 0,090.05 0,04

NOTE: For glass values that are not listed, linear interpolation is permitted.

1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4").

Page 19: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

0,48 (2,73)

0,46 (2,61)

0,44 (2,50)

0,42 (2,39)

0,40 (2,27)

0,38 (2,16)

0,36 (2,05)

0,34 (1,93)

0,32 (1,82)

0,30 (1,71)

0,28 (1,59)

0,26 (1,48)

0,24 (1,37)

0,22 (1,25)

0,20 (1,14)

TrifabTM 451UT Framing System 19AUGUST, 2016

ADMC060EN

THERMAL CHARTS - WITH STEEL

Note:Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507.

System U-Factor for Vision Glass

COG U-factor

Vision Area / Total Area (%)

Syst

em U

-Fac

tor (

Btu

/h·ft

2 ·°F)

Page 20: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

TrifabTM 451UT Framing System20 AUGUST, 2016

ADMC060EN

THERMAL CHARTS - WITH STEEL

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision AreaCOG

SHGC

COG VT

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Area / Total Area (%)

Vision Ares / Total Area (%)

Syst

em S

HG

C

Charts are generated per AAMA 507.

Charts are generated per AAMA 507.

Syst

em V

T

Page 21: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

TrifabTM 451UT Framing System 21AUGUST, 2016

ADMC060EN

THERMAL PERFORMANCE MATRIX (NFRC SIZE) - WITH STEEL

TrifabTM 451UT with Steel

Thermal Transmittance 1 (BTU/hr • ft 2 • °F)Glass U-Factor 3 Overall U-Factor 4

0.48 0.570.46 0.560.44 0.540.42 0.530.40 0.510.38 0.490.36 0.480.34 0.460.32 0.450.30 0.430.28 0.410.26 0.400.24 0.380.22 0.360.20 0.35

SHGC Matrix 2

Glass SHGC 3 Overall SHGC 4

0.75 0.660.70 0.620.65 0.580.60 0.530.55 0.490.50 0.450.45 0.400.40 0.360.35 0.320.30 0.270.25 0.230.20 0.190.15 0.140.10 0.100.05 0.05

Visible Transmittance 2

Glass VT 3 Overall VT 4

0.75 0.650.70 0.610.65 0.570.60 0.520.55 0.480.50 0.440.45 0.390.40 0.350.35 0.300.30 0.260.25 0.220.20 0.170.15 0.130.10 0.090.05 0.04

NOTE: For glass values that are not listed, linear interpolation is permitted.

1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4").

Page 22: Trifab TM 451UT Framing System - Arconic / deadload charts ..... 11-14 thermal charts ..... 15-21 index (center) laws and building and safety codes governing the design and use of

Law

s an

d bu

ildin

g an

d sa

fety

cod

es g

over

ning

the

desi

gn a

nd u

se o

f gla

zed

entra

nce,

win

dow

, and

cur

tain

wal

l pro

duct

s va

ry w

idel

y. K

awne

er d

oes

not c

ontro

l th

e se

lect

ion

of p

rodu

ct c

onfig

urat

ions

, ope

ratin

g ha

rdw

are,

or g

lazi

ng m

ater

ials

, an

d as

sum

es n

o re

spon

sibi

lity

ther

efor

.

Kaw

neer

rese

rves

the

right

to c

hang

e co

nfigu

ratio

n w

ithou

t prio

r not

ice

whe

n de

emed

nece

ssar

y fo

r pro

duct

impr

ovem

ent.

© K

awne

er C

ompa

ny, I

nc.,

2013

kawneer.com

EC 97911-110

TrifabTM 451UT Framing System22 AUGUST, 2016

ADMC060EN

BLANK PAGE