3
REVISIONS AND ISSUES DRAWING TITLE PROJECT DRAWN DATE FILE NAME DRAWING NORTH SCALE Copyright. All rights reserved. Reproduction in whole or in part is prohibited. This drawing as an instrument of service is the property of the Consultant and may not be used in any way without the written permission of this office. PROJECT NO. REVIEWED PLOTTED NO. DATE DESCRIPTION 1468 Plan.vwx TREE MANAGEMENT PLAN KEEFER AND COLUMBIA CL BH 1468 September 15, 2014 16-11-30 at 2:20:09 PM 1/8" = 1'-0" L 0.01 2014/09/11 Issued for Rezoning Prior-to 2015/07/10 Reissued for Rezoning Prior-to 03 2016/04/08 Issued for Coordination 04 2016/04/13 Reissued for Rezoning Prior-To 05 2016/11/30 Reissued for Rezoning Prior-To 5th Floor, East Asiatic House 1201 West Pender Street Vancouver BC Canada V6E 2V2 www.pwlpartnership.com T 604.688.6111 F 604.688.6112 PWL partnership PWL Partnership Landscape Architects Inc 7'-7 1/2" LANE H G COLUMBIA ST. TREE MANAGEMENT LEGEND: EXISTING TREE TO BE REMOVED TREE PROTECTION BARRIER FENCE REFER TO TREE PROTECTION NOTES FOR REQUIREMENTS EXISTING TREE TO BE RETAINED TREE PROTECTION GENERAL NOTES A. EXCAVATION AROUND TREES 1. EXCAVATION WITHIN DRIP LINE OF TREES ONLY WHERE INDICATED ON PLANS AND AS DIRECTED BY THE CONSULTANT. 2. DURING ANY EXCAVATION WITHIN THE DRIP LINE OF A TREE THE CONTRACTOR SHALL EXCAVATE AROUND TREE ROOTS AS DIRECTED BY THE CONSULTANT. DO NOT CUT TREE ROOTS UNLESS DIRECTED BY THE CONSULTANT. 3. TREES AND OTHER DESIRABLE VEGETATION TO BE TOTALLY FENCED AS PER DETAIL #1. FENCING TO BE MAINTAINED FOR THE DURATION OF THE PROJECT. B. EXCAVATION FOR NEW CONSTRUCTION WITHIN THE DRIP LINES OF TREES 1. HAND EXCAVATE TO MINIMIZE DAMAGE TO ROOT SYSTEMS. 2. USE NARROW TINE SPADING FORKS TO PROBE AND COMB SOIL TO EXPOSE ROOTS. 3. RELOCATE ROOTS INTO BACKFILL AREAS WHENEVER POSSIBLE. IF LARGE MAIN LATERAL ROOTS ARE ENCOUNTERED, EXPOSE BEYOND EXCAVATION LIMITS AS REQUIRED TO BEND AND RELOCATE WITHOUT BREAKING. C. UTILITY TRENCHING WITHIN THE DRIP LINES OF TREES 1. TUNNEL UNDER AND AROUND ROOTS BY HAND DIGGING. 2. DO NOT CUT MAIN LATERAL ROOTS. 3. CUTTING OF SMALLER ROOTS THAT INTERFERE WITH INSTALLATION OF NEW WORK SHALL BE DONE WITH CLEAN SHARP TREE PRUNING TOOLS. 4. ROOTS THAT ARE ENCOUNTERED IMMEDIATELY ADJACENT TO THE LOCATION OF NEW CONSTRUCTION AND ARE TOO DIFFICULT TO RELOCATE SHALL BE CUT 150MM (6") BACK FROM NEW CONSTRUCTION. USE CLEAN SHARP TREE PRUNING TOOLS. D. PROTECTION OF EXPOSED ROOTS 1. DO NOT ALLOW EXPOSED ROOTS TO DRY OUT PRIOR TO PLACEMENT OF PERMANENT COVER. PROVIDE ONE OF THE FOLLOWING TEMPORARY REMEDIAL MEASURES: A. PROVIDE TEMPORARY EARTH COVER. MAINTAIN MOISTURE. B. PACK WITH WET PEAT MOSS. MAINTAIN MOISTURE. C. PACK WITH FOUR LAYERS OF WET UNTREATED BURLAP. MAINTAIN MOISTURE. 2. TEMPORARILY SUPPORT AND PROTECT EXPOSED ROOTS FROM DAMAGE UNTIL PERMANENTLY RELOCATED AND COVERED WITH BACKFILL. 3. WATER PUDDLE BACKFILL AROUND ROOTS TO ELIMINATE VOIDS AND AIR POCKETS. E. REMOVAL OF STREET TREES 1. REMOVAL OF STREET TREES TO THE SATISFACTION OF THE GENERAL MANAGER OF ENGINEERING SERVICES 1.2 1.5 2.1 2.4 2.7 3.0 3.3 3.6 4.5 5.0 6.0 20 25 35 40 45 50 55 60 75 90 100 0.6 0.8 1.0 1.2 1.3 1.5 1.7 2.0 2.5 3.0 3.3 SCHEDULE A - TREE PROTECTION BARRIER TREE PROTECTION DISTANCE TABLE TREE PROTECTION BARRIERS MUST BE AT LEAST 1.2 M IN HEIGHT. TRUNK DIAMETER MINIMUM DISTANCE FROM TRUNK (METERS) (CM) (FT.) OPEN FENCING 1.20m HEIGHT 1 TREE PROTECTION BARRIER FENCING DETAIL nts 2 x 4 TIMBER STAKES MAX 1.0m O.C.

TREE PROTECTION GENERAL NOTES - Vancouver · 2016. 12. 15. · tree management legend: existing tree to be removed tree protection barrier fence refer to tree protection notes for

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TREE PROTECTION GENERAL NOTES - Vancouver · 2016. 12. 15. · tree management legend: existing tree to be removed tree protection barrier fence refer to tree protection notes for

REVISIONS AND ISSUES

DRAWING TITLE

PROJECT

DRAWN

DATE

FILE NAME

DRAWING

NORTH SCALE

Copyright. All rights reserved. Reproduction in whole or in part is prohibited. This drawing as aninstrument of service is the property of the Consultant and may not be used in any way without thewritten permission of this office.

PROJECT NO.

REVIEWED

PLOTTED

NO. DATE DESCRIPTION

1468 Plan.vwx

TREE MANAGEMENTPLAN

KEEFER AND COLUMBIA

CL BH

1468

September 15, 2014

16-11-30 at 2:20:09 PM

1/8" = 1'-0"

L 0.01

2014/09/11 Issued for Rezoning Prior-to

2015/07/10 Reissued for Rezoning Prior-to

03 2016/04/08 Issued for Coordination

04 2016/04/13 Reissued for Rezoning Prior-To

05 2016/11/30 Reissued for Rezoning Prior-To

5th Floor, East Asiatic House1201 West Pender StreetVancouver BC Canada V6E 2V2

www.pwlpartnership.com

T 604.688.6111F 604.688.6112

PWL partnership

PWL Partnership Landscape Architects Inc

7'-7

1/2

"

CO

LU

MB

IA S

T.

LANE

H

G

CO

LU

MB

IA S

T.

TREE MANAGEMENT LEGEND:

EXISTING TREE TO BE REMOVED

TREE PROTECTION BARRIER FENCE REFER TO TREE PROTECTION NOTES FOR REQUIREMENTS

EXISTING TREE TO BE RETAINED

TREE PROTECTION GENERAL NOTES

A. EXCAVATION AROUND TREES

1. EXCAVATION WITHIN DRIP LINE OF TREES ONLY WHERE INDICATED ON PLANS AND ASDIRECTED BY THE CONSULTANT.

2. DURING ANY EXCAVATION WITHIN THE DRIP LINE OF A TREE THE CONTRACTOR SHALL EXCAVATE AROUND TREE ROOTS AS DIRECTED BY THE CONSULTANT. DO NOT CUT TREEROOTS UNLESS DIRECTED BY THE CONSULTANT.

3. TREES AND OTHER DESIRABLE VEGETATION TO BE TOTALLY FENCED AS PER DETAIL #1. FENCING TO BE MAINTAINED FOR THE DURATION OF THE PROJECT.

B. EXCAVATION FOR NEW CONSTRUCTION WITHIN THE DRIP LINES OF TREES

1. HAND EXCAVATE TO MINIMIZE DAMAGE TO ROOT SYSTEMS.

2. USE NARROW TINE SPADING FORKS TO PROBE AND COMB SOIL TO EXPOSE ROOTS.

3. RELOCATE ROOTS INTO BACKFILL AREAS WHENEVER POSSIBLE. IF LARGE MAIN LATERALROOTS ARE ENCOUNTERED, EXPOSE BEYOND EXCAVATION LIMITS AS REQUIRED TO BENDAND RELOCATE WITHOUT BREAKING.

C. UTILITY TRENCHING WITHIN THE DRIP LINES OF TREES

1. TUNNEL UNDER AND AROUND ROOTS BY HAND DIGGING.

2. DO NOT CUT MAIN LATERAL ROOTS.

3. CUTTING OF SMALLER ROOTS THAT INTERFERE WITH INSTALLATION OF NEW WORK SHALL BEDONE WITH CLEAN SHARP TREE PRUNING TOOLS.

4. ROOTS THAT ARE ENCOUNTERED IMMEDIATELY ADJACENT TO THE LOCATION OF NEWCONSTRUCTION AND ARE TOO DIFFICULT TO RELOCATE SHALL BE CUT 150MM (6") BACK FROM NEW CONSTRUCTION. USE CLEAN SHARP TREE PRUNING TOOLS.

D. PROTECTION OF EXPOSED ROOTS

1. DO NOT ALLOW EXPOSED ROOTS TO DRY OUT PRIOR TO PLACEMENT OF PERMANENT COVER.PROVIDE ONE OF THE FOLLOWING TEMPORARY REMEDIAL MEASURES:

A. PROVIDE TEMPORARY EARTH COVER. MAINTAIN MOISTURE.B. PACK WITH WET PEAT MOSS. MAINTAIN MOISTURE.C. PACK WITH FOUR LAYERS OF WET UNTREATED BURLAP. MAINTAIN MOISTURE.

2. TEMPORARILY SUPPORT AND PROTECT EXPOSED ROOTS FROM DAMAGE UNTIL PERMANENTLYRELOCATED AND COVERED WITH BACKFILL.

3. WATER PUDDLE BACKFILL AROUND ROOTS TO ELIMINATE VOIDS AND AIR POCKETS.

E. REMOVAL OF STREET TREES

1. REMOVAL OF STREET TREES TO THE SATISFACTION OF THE GENERAL MANAGER OF ENGINEERING SERVICES

1.21.52.12.42.73.03.33.64.55.06.0

20253540455055607590

100

0.60.81.01.21.31.51.72.02.53.03.3

SCHEDULE A - TREE PROTECTION BARRIER

TREE PROTECTION DISTANCE TABLE

TREE PROTECTION BARRIERS MUST BE AT LEAST 1.2 M IN HEIGHT.

TRUNK DIAMETER

MINIMUM DISTANCE FROM TRUNK (METERS)

(CM) (FT.)

OPEN FENCING 1.20m HEIGHT

1TREE PROTECTION BARRIER FENCING DETAIL

nts

2 x 4 TIMBER STAKES MAX 1.0m O.C.

Page 2: TREE PROTECTION GENERAL NOTES - Vancouver · 2016. 12. 15. · tree management legend: existing tree to be removed tree protection barrier fence refer to tree protection notes for

REVISIONS AND ISSUES

DRAWING TITLE

PROJECT

DRAWN

DATE

FILE NAME

DRAWING

NORTH SCALE

Copyright. All rights reserved. Reproduction in whole or in part is prohibited. This drawing as aninstrument of service is the property of the Consultant and may not be used in any way without thewritten permission of this office.

PROJECT NO.

REVIEWED

PLOTTED

NO. DATE DESCRIPTION

1468 Plan.vwx

C0LOUR PLANGROUND LEVEL

KEEFER AND COLUMBIA

CL BH

1468

September 15, 2014

16-11-30 at 2:22:45 PM

1/8" = 1'-0"

L 1.01

2014/09/11 Issued for Rezoning Prior-to

2015/07/10 Reissued for Rezoning Prior-to

03 2016/04/08 Issued for Coordination

04 2016/04/13 Reissued for Rezoning Prior-To

05 2016/11/30 Reissued for Rezoning Prior-To

5th Floor, East Asiatic House1201 West Pender StreetVancouver BC Canada V6E 2V2

www.pwlpartnership.com

T 604.688.6111F 604.688.6112

PWL partnership

PWL Partnership Landscape Architects Inc

7'-7

1/2

"

CO

LU

MB

IA S

T.

LANE

1

3

13

3

3 7

7

7 62 3

4

5

4

5

2

4

5

7

H

G

EXTENT OF EXISTING SIDEWALK AND PLAZA

EXISTING BOLLARD, TYP. EXISTING LIGHT POLE, TYP.PROPOSED CURB

CONCRETE PLANTER

1

URBAN AGRICULTURE PLANTER

2

KEY DESCRIPTION

HARDSCAPE LEGEND

STAMPED CONCRETE SIDEWALK TO MATCH EXISTING

1

CONCRETE PAVING

2

EXPOSED AGGREGATE CONCRETE PAVING

3

GRANITE SETTS

4

GRANITE BANDS

5

GLASS BLOCK PAVING

6

MOSAIC TILE

7

FEATURE PAVING TYPE 1

8

FEATURE PAVING TYPE 2

9

TIMBER DECK

10

RIVER ROCK

11

KEY DESCRIPTION

PAVING LEGEND

RETRACTABLE FABRIC AWNING

1

SCREEN

2

BBQ

3

HARVEST TABLE AND BENCHES

4

POTTING BENCH

5

COMPOST BIN

6

OUTDOOR SEATING

7

KEY DESCRIPTION

SITE FURNISHING LEGEND

CATENARY LIGHITNG

1

KEY DESCRIPTION

LIGHTING LEGEND

NOTE: - REFER TO SHEET L1.02 FOR GROUND LEVEL

Page 3: TREE PROTECTION GENERAL NOTES - Vancouver · 2016. 12. 15. · tree management legend: existing tree to be removed tree protection barrier fence refer to tree protection notes for

REVISIONS AND ISSUES

DRAWING TITLE

PROJECT

DRAWN

DATE

FILE NAME

DRAWING

NORTH SCALE

Copyright. All rights reserved. Reproduction in whole or in part is prohibited. This drawing as aninstrument of service is the property of the Consultant and may not be used in any way without thewritten permission of this office.

PROJECT NO.

REVIEWED

PLOTTED

NO. DATE DESCRIPTION

1468 Plan.vwx

C0LOUR PLANOVERALL

KEEFER AND COLUMBIA

CL BH

1468

September 15, 2014

16-11-30 at 2:22:38 PM

1/8" = 1'-0"

L 1.02

2014/09/11 Issued for Rezoning Prior-to

2015/07/10 Reissued for Rezoning Prior-to

03 2016/04/08 Issued for Coordination

04 2016/04/13 Reissued for Rezoning Prior-To

05 2016/11/30 Reissued for Rezoning Prior-To

5th Floor, East Asiatic House1201 West Pender StreetVancouver BC Canada V6E 2V2

www.pwlpartnership.com

T 604.688.6111F 604.688.6112

PWL partnership

PWL Partnership Landscape Architects Inc

4'-2"

2

9

9

1

2

3

5

6

1

2

1

1

1

11 1

1

1

1

2

2

3

4

7

1110

10

10

10

9

8

9

8

9

8

9

8

8

9

8

9

8

9

8

1 9

8

1

9

8

2

3

1

H

G

GLASS SKYLIGHT, TYP.

L9

L10 L10

L10

L11

L2

RF

RF

L9

L2

L2

L10

L10

GINGKO BILOBA TREES, typ.

ACER GRISEUM TREES, typ.

L8

GINGKO BILOBA TREES, typ.

L10

NOTE: - REFER TO SHEET L1.01 FOR GROUND LEVEL

- FOR LEVELS REFER TO MARKERSL

CONCRETE PLANTER

1

URBAN AGRICULTURE PLANTER

2

KEY DESCRIPTION

HARDSCAPE LEGEND

STAMPED CONCRETE SIDEWALK TO MATCH EXISTING

1

CONCRETE PAVING

2

EXPOSED AGGREGATE CONCRETE PAVING

3

GRANITE SETTS

4

GRANITE BANDS

5

GLASS BLOCK PAVING

6

MOSAIC TILE

7

FEATURE PAVING TYPE 1

8

FEATURE PAVING TYPE 2

9

TIMBER DECK

10

RIVER ROCK

11

KEY DESCRIPTION

PAVING LEGEND

RETRACTABLE FABRIC AWNING

1

SCREEN

2

BBQ

3

HARVEST TABLE AND BENCHES

4

POTTING BENCH

5

COMPOST BIN

6

OUTDOOR SEATING

7

KEY DESCRIPTION

SITE FURNISHING LEGEND

CATENARY LIGHITNG

1

KEY DESCRIPTION

LIGHTING LEGEND