1
WHAT WILL I LEARN FROM THIS COURSE? WHO SHOULD ATTEND? PREREQUISITES TUITION COURSE DURATION CEU CREDITS OFFERED AGENDA Contact us for custom and on-site pricing. g GE Multilin TRNG-LINE TRANSMISSION LINE PROTECTION PRINCIPLES WITH THE ALPS, D60, L90, L60 This course begins with an overview of basic Transmission Line terminology, Distance theory, Distance schemes in addition to Differential Line protection. Through a combination of lectures and practical Lab exercises, the class will learn how to correctly configure the D60 and ALPS Distance relays the L90 line current differential and L60 LinePhase Comparison. Electrical maintenance and engineering personnel who wish to gain a better understanding of Transmission Line protection and the procedures to install and configure the GE Multilin Transmission Line Protection Relays. Basic understanding of electrical circuits The Transmission Line Protection Interactive Learning CD would be an asset $ 3,000 US* 5 Days 3.5 Credits Transmission Line fundamentals Relaying basics Circuit Breakers Primary and Backup relaying Introduction to Symmetrical component Current Transformers Potential Transformers Universal Relay Hardware overview UR Modular concept Family members Hardware configuration Mechanical installation Options and ordering Settings Product Setup System Setup Commands Virtual Inputs Clear Records Set Date and Time Actual Values Front Panel Status and Metering Status and Metering Lab Introduction to FlexLogic Logic Gates Programming Flexlogic equations Oscillography and Event Log Lab Fault Diagnostic Lab Saving/loading settings files Maintenance procedures Adding/Removing modules Grouped Elements Phase Differential protective theory Protection element calculations for a typical L60 application and demonstration Lab Line Current Differential theory Protection element calculations for a typical L90 application L90 demonstration Lab Introduction to Transmission Lines Distance protection theory Stepped distance Zone 1 extended Pilot aided schemes: DUTT, PUTT, POTT, HYBRID POTT, Directional-blocking Power swings D60 overview Protection element calculations for a typical D60 application and demonstration Lab ALPS overview Hardware overview Mechanical and wiring instructions Protection element overview Configuration software Communication testing Relay maintenance Day 1 Day 2 Day 3 Day 5 Introduction to the Universal Relay EnerVista UR Setup Software D60/ALPS Relays Day 4 L60/L90 Relays Introduction This class includes fully equipped Hands-On Lab exercises. 25% off the price of the training CD when purchased with the in-class course

Transmission Lines-Protection Principles

Embed Size (px)

DESCRIPTION

Transmission Lines-Protection Principles

Citation preview

Page 1: Transmission Lines-Protection Principles

WHAT WILL I LEARN FROM THIS COURSE? WHO SHOULD ATTEND?

PREREQUISITES TUITION

COURSE DURATION CEU CREDITS OFFERED

AGENDA

* Tuition shown is for scheduled courses. Contact us for custom and on-site pricing.g GE Multilin

TRNG-LINETRANSMISSION LINEPROTECTION PRINCIPLESWITH THE ALPS, D60, L90, L60

This course begins with an overview of basic Transmission Line terminology, Distance theory, Distance schemes in addition to Differential Line protection. Through a combination of lectures and practical Lab exercises, the class will learn how to correctly confi gure the D60 and ALPS Distance relays the L90 line current differential and L60 LinePhase Comparison.

Electrical maintenance and engineering personnel who wish to gain a better understanding of Transmission Line protection and the procedures to install and confi gure the GE Multilin Transmission Line Protection Relays.

Basic understanding of electrical circuitsThe Transmission Line Protection Interactive Learning CD would be an asset

$ 3,000 US*

5 Days 3.5 Credits

Transmission Line fundamentalsRelaying basicsCircuit BreakersPrimary and Backup relayingIntroduction to Symmetrical componentCurrent TransformersPotential Transformers

Universal Relay Hardware overviewUR Modular conceptFamily members Hardware confi guration

Mechanical installationOptions and ordering

SettingsProduct SetupSystem Setup

CommandsVirtual InputsClear RecordsSet Date and Time

Actual ValuesFront PanelStatus and MeteringStatus and Metering Lab

Introduction to FlexLogicLogic Gates

Programming Flexlogic equationsOscillography and Event Log LabFault Diagnostic LabSaving/loading settings fi lesMaintenance proceduresAdding/Removing modules

Grouped ElementsPhase Differential protective theory Protection element calculations for a typical L60 application and demonstration Lab Line Current Differential theory Protection element calculations for a typical L90 application L90 demonstration Lab

Introduction to Transmission LinesDistance protection theoryStepped distanceZone 1 extendedPilot aided schemes: DUTT, PUTT, POTT, HYBRID POTT, Directional-blockingPower swingsD60 overview Protection element calculations for a typical D60 application and demonstration Lab ALPS overviewHardware overviewMechanical and wiring instructionsProtection element overviewConfi guration softwareCommunication testing Relay maintenance

Day 1

Day 2

Day 3 Day 5

Introduction to the Universal Relay

EnerVista UR Setup Software

D60/ALPS Relays

Day 4L60/L90 Relays

Introduction

This class includes fully equipped Hands-On Lab exercises.

Interactive Learning CD Available Interactive Learning CD Available See Page 54See Page 54

25% off the price of the training CD when purchased with the in-class course