34
July 2002 Edition Ultrasonic Transducers AgfaNDT.com

Transductores UT, Dual o Simple

Embed Size (px)

Citation preview

  • July 2002 Edition

    UltrasonicTransducers

    AgfaNDT.com

  • General Information

    KrautkramerThe World LeaderKrautkramer is the worlds largest designer, manufacturer, and marketer of high technologyinstruments and transducers for ultrasonic nondestructive testing (UT). Our products include flawdetectors, thickness gauges, hardness testers, inspection systems, UT software, ultrasonictransducers, and eddy current instruments and probes. Krautkramer is a division of Emerson Electricand has worldwide manufacturing and product support bases. Our main manufacturing centers are inLewistown, Pennsylvania, USA, and Cologne, Germany. We also have direct facilities in Japan, UnitedKingdom, France, and Italy, as well as worldwide representatives. All of our direct facilities and manyof our representative facilities have full service capabilities. A full list of worldwide representatives isavailable from Krautkramer or on the Internet at www.krautkramer.com.

    Ultrasonic Transducers for Every ApplicationKrautkramer offers over 4000 standard and special ultrasonic transducers and accessories forvirtually every application. This catalog describes our extensive range of standard transducers andrelated accessories. For applications that require a non-standard product, we proudly offer the mostcomprehensive special probe and applications services available anywhere. Refer to the SpecialProbes and Applications section of this catalog for more information.

    Fast DeliveryBecause we know that fast delivery is a must for most of our customers, we stock over 500 of thecommonly used products in this catalog. If your first choice is not available from stock, a productspecialist can often recommend a suitable substitute. When not available from stock, most standardproducts in this catalog can be shipped in less than two weeks. As a certified Class A MRPIImanufacturer, Krautkramer employs state-of-the-art control systems and manufacturing methods toassure timely delivery of a reliable product.

    The Best Quality and ServiceOur quality program is certified to the international quality standardISO-9001. This enables Krautkramer to quickly serve the marketplacewith products of exceptional quality and value. Krautkramerscommitment to providing the very best customer service is evidencedby ongoing investments in manufacturing technology and productivityenhancing capital equipment.

    New ProductsNumerous products are included in this catalog for the first time. Below are a few of the most important ones:

    Look for new Benchmark Series probes throughout the catalog. Made with proprietaryBENCHMARK COMPOSITE active elements, they offer incredible penetration and excellentresolution. Refer to the Transducer Performance section of the catalog for more information.

    Use new XLC Extended Life Contact probes for long service life in the most abusive applications. Try the new K-PEN 20 MHz pencil type probe on parts with sharp curves or limited access. Use the HT400A high temperature probe to test materials at temperatures to 1000F. Save time and money with FASTTM probes, designed for high speed, manual weld scanning.

  • 1Table of Contents

    How to Order ........................................ 1

    Transducer PerformanceAlpha Series Features...................... 2Benchmark Series Features ............. 2Gamma Series Features .................. 2Frequency Color Coding ................... 2

    Contact TransducersRHP Style Standard ......................... 3XLC Style Extended Life ................... 3F Style Fingertip .............................. 4

    Delay Line Contact TransducersDFR Style Removable Delay ............. 4K-PEN Pencil Type Probe .................. 5ZIP Probes ...................................... 5

    Protective Face Contact TransducersPFCR/PFCS Combination Styles ....... 6PMCR/PMCS Membrane Styles ........ 7PWCCR/PWCCS Styles .................... 8

    Angle Beam TransducersSWS/AWS Styles, Gamma ............... 9SWS/AWS Styles, Benchmark ........ 10

    Miniature Angle Beam TransducersMSW-QC Quick Change, Gamma..... 11MSW-QC, Alpha & Benchmark ........ 12MSWS Style (Captive Screws) ........ 13ABFP Style (Potted Wedge) ............. 14SMSWS Style (Subminiature) ......... 14

    Fingertip Dual Element TransducersADP Style (Potted Cable) ................ 15RC Dual Style (Replaceable Cable) . 15FDU Style (Replaceable Cable) ....... 15

    High Temperature Dual Element TransducersHT400A (to 1000 F) ..................... 15KBA560V (to 750 F) ..................... 15

    Standard Dual Element TransducersDU Style (Replaceable Delay) ......... 16DU-F Style, Benchmark Series ........ 16FASTTM Probes ............................... 16

    Immersion TransducersISS/IS Styles ................................ 17IPS/IR Styles ................................ 18Velocity System Transducers .......... 19Near Field and Focusing Information . 19

    Thickness Gauging TransducersPrecision Gauging .......................... 20Dual Element Corrosion Gauging .... 21

    Special Probes and Applications LaboratorySpecial Probes & Applications ........ 22Phased Array Transducers .............. 23Inquiry Form.................................. 24

    AccessoriesCables/Adaptors/Search Tubes ..... 25Couplants ..................................... 26Test Blocks ................................... 27

    Transducer Certification ...................... 29

    Tables and Formulas ........................... 30

    Transducer Kits............. Inside Back Cover

    How To Order Order by Product Code: Tables on each page give Product Codes by frequency, size, and style. Phone: (717) 242-0327. Ask for the Sales Department. After hours, use our voice mail system. Fax: (717) 242-2606 Mail: Sales Department, Krautkramer, 50 Industrial Park Road, Lewistown, PA 17044 Contact your local Sales Representative: See our site on the web at www.krautkramer.com or call

    our Sales Department If you need assistance: Call (717) 242-0327 and ask for a Transducer Product Specialist. VISA and MasterCard accepted in North America when you order through our Lewistown, PA office.

    Page Page

  • 2Transducer PerformanceKrautkramer offers three series of transducers: Alpha, Gamma, and new Benchmark. To determinewhich of these series is best for your application, please read the technical information on this page.If you need assistance, contact one of our Transducer Product Specialists (717-242-0327) or your localsales representative. Real time waveform and frequency certification is included with every transducerat no charge (refer to the Technical Information section for details).

    )zHM(ycneuqerF 05. 0.1 52.2 05.3 00.5 00.01

    roloC yarG deR wolleY eulB neerG kcalB

    Recommended for applications where resolution is the primary consideration. Suitable for applications such as thickness measurement and near-surface

    flaw detection. Very short pulsemechanically damped to the limit of current technology. Gain is usually lower than that of the Gamma and Benchmark Series. Broadbandtypical 6 dB bandwidths range from 50% to 100%. Typical Alpha waveforms (right) exhibit one to two full ring cycles, depending

    on frequency, size and other parameters.

    Proprietary BENCHMARK COMPOSITE (piezocomposite) active elements. Penetration in attenuative materials is far superior to conventional transducers. High signal to noise on coarse grain metals, fiber reinforced composites, et al. Short pulseresolution usually superior to Gamma Series. Gain is usually higher than that of the Gamma and Alpha Series. Very broadbandtypical 6 dB bandwidths range from 60% to 120%. Low acoustic impedance element improves performance of angle beam,

    delay line, and immersion probesexcellent match to plastic and water.

    General purpose transducers, recommended for the majority of applications. Medium pulse, medium dampingbest combination of gain and resolution Matching electrical network ensures maximum gain and optimum waveform

    for general use. Medium bandwidthtypical 6 dB bandwidths range from 30% to 50%. Typical Gamma waveform exhibits three to four full ring cycles, depending on

    frequency, size and other parameters.

    For easy identification of frequency, most Krautkramer transducers are color coded as follows:

  • 3Contact TransducersSingle Element Contact Transducers are longitudinal wave transducers designed for general purposemanual ultrasonic inspection where test materials are relatively flat and smooth. Contact transducersprovide high sensitivity for better penetration and are ruggedly constructed for extended service lifeunder the roughest testing conditions.

    tnemelEretemaiD

    A B

    005. 51.1 05.1

    057. 04.1 05.1

    000.1 56.1 05.1

    Standard Contact TransducersRHP and XLC Styles

    RHP and XLC Style ContactsStandard Contact Transducers are designed for abusive scrubbingapplications. Gamma series are for applications where sensitivity andpenetration are essential. Alpha series have maximum bandwidth foraxial resolution. RHP style probes feature ceramicwearplates for the best combination of acoustic matchingand durability and stainless steel housings to resistcorrosion. New XLC (Extended Life Contact) style probeshave special, high durability wearplates for the mostabusive applications. Both styles feature an improvedcomfort grip and color band for frequency identification.CR models have right angle mounted BNC connectorsand the CS models have top-mounted BNC connectors.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    seirosseccAelytS

    ahplAseireS

    ammaGseireS

    5.

    057.PHRPHR

    RC-340-052SC-321-052

    selbaC

    CNB'6610-C

    OMEL'6810-C

    00.1PHRPHR

    RC-340-062SC-321-062

    0.1

    005.PHRPHR

    RC-340-142SC-321-142

    057.PHRPHR

    RC-340-152SC-321-152

    00.1

    PHRPHRCLXCLX

    RC-340-162SC-321-162RC-050-162SC-051-162

    52.2

    005.

    PHRPHRCLXCLX

    RC-340-241SC-321-241

    RC-340-242SC-321-242RC-050-242SC-051-242

    057.

    PHRPHRCLXCLX

    RC-340-251SC-321-251

    RC-340-252SC-321-252RC-050-252SC-051-252

    00.1

    PHRPHRCLXCLX

    RC-340-261SC-321-261

    RC-340-262SC-321-262RC-050-262SC-051-262

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    elytSahplAseireS

    ammaGseireS

    seirosseccA

    5.3

    005.

    PHRPHRCLXCLX

    RC-340-342SC-321-342RC-050-342SC-051-342

    selbaC

    CNB'6610-C

    OMEL'6810-C

    057.

    PHRPHRCLXCLX

    RC-340-352SC-321-352RC-050-352SC-051-352

    00.1

    PHRPHRCLXCLX

    RC-340-362SC-321-362RC-050-362SC-051-362

    0.5

    005.PHRPHR

    RC-340-441SC-321-441

    RC-340-442SC-321-442

    057.PHRPHR

    RC-340-451SC-321-451

    RC-340-452SC-321-452

    00.1PHRPHR

    RC-340-461SC-321-461

    RC-340-462SC-321-462

    0.01 005.PHRPHR

    RC-340-642SC-321-642

  • 4Contact TransducersSingle Element Contact Transducers are longitudinal wave transducersdesigned for general purpose manual ultrasonic inspection where testmaterials are relatively flat and smooth. Contact transducers providehigh sensitivity for better penetration and are ruggedly constructedfor extended service life under the roughest testing conditions.

    F Style ContactF Style Contact transducers are small diameter fingertip probeswith a right angle mounted Microdot connector. Gamma Seriesare recommended for applications where high sensitivityand penetration are essential. Alpha Series are designedfor optimum damping and resolution. Benchmark Series,with Benchmark Composite elements, are best forpunching through highly attenuative materials.

    tnemelEretemaiD

    A B

    052. 05. 66.

    573. 36. 66.

    005. 57. 66.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    kramhcneBseireS

    ahplAseireS

    ammaGseireS

    seirosseccAkramhcneB

    seireSahplAseireS

    ammaGseireS

    seirosseccA

    52.2

    052. 000-228 000-221 000-222

    selbaC

    CNB'6210-C

    OMEL'6220-C

    0.5

    052. 000-428 000-421 000-422

    selbaC

    CNB'6210-C

    OMEL'6220-C

    573. 000-238 000-231 000-232 573. 000-438 000-431 000-432

    005. 000-248 000-241 000-242 005. 000-448 000-441 000-442

    5.3

    052. 000-321 000-322

    0.01

    052. 000-621 000-622

    573. 000-331 000-332 573. 000-631 000-632

    005. 000-341 000-342 005. 000-641 000-642

    Fingertip Contact TransducersF Style

    DFR Style Removable Delay Line Contact

    DFR Style Removable Delay Line Fingertip Transducers are specificallydesigned for thickness gauging and flaw detection of thin materials.High frequency and critical damping results in a high performancetransducer, which exhibits excellent resolution capability. All DFR StyleTransducers have right angle mounted Microdot connectors.

    tnemelEretemaiD

    A B C

    ro521.052.

    15. 538. 03.

    005. 578. 573.1 595.

    RFD-iniM

    521. 14. 567. 91.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    ahplAseireS

    eniLyaleDgL"83.KP-01

    eniLyaleDgL"5.KP-01 seirosseccA

    52.2052. 066-221 050-D 150-D

    selbaC

    CNB'6210-C

    OMEL'6220-C

    eniLyaleDtnalpuoC

    047-DX

    gnirpSdedaoL

    EEVkcolB*700-H

    005. 005-041 250-D

    5.3 052. 066-321 050-D 150-D

    0.5052. 066-421 050-D 150-D

    005. 066-441 250-D

    0.01052. 066-621 050-D 150-D

    005. 06-041 2 250-D

    0.51 052. 066-721 050-D 150-D

    0.22 521. 066-811 050-D 150-D

    0.52 052. 066-921 050-D 150-D

    RFD-iniM0.02 521. 056-815 205-DM

    Removable Delay LineDFR Style

    *H-007 fits .125 and .25 units only with exception of Mini DFR.

  • 5Contact TransducersSingle Element Contact Transducers are longitudinal wave transducers designed for general purposemanual ultrasonic inspection where test materials are relatively flat and smooth. Contact transducersprovide high sensitivity for better penetration and are ruggedly constructed for extended service lifeunder the roughest testing conditions.

    K-PEN Replaceable Delay Line Pencil ProbeK-PEN's are high resolution pencil type probes. They aredesigned for applications requiring an extremely smallcontact area, such as tightly curved surfaces of turbineblades or remaining wall thickness measurements from apit bottom. They can be used with most flaw detectors,precision thickness gauges, and general pulser / receiverunits. Probes come with interchangeable delay tips that aretapered to a .065" and .090" contact diameter.Replacement delays are available in packs of 10. Thestraight model fetures a removable handle, which alsoallows it to be used as a fingertip probe. All models haveMicrodot connectors.

    .qerF)zHM(

    SEDOCTCUDORP

    thgiartSNEP-K

    54NEP-K

    elgnAthgiRNEP-K

    yaleDpiT"560.KP-01

    yaleDpiT"090.KP-01

    CNB'6elbaC

    5.7 002-240-983 088-240-983 078-240-983901-300-783 011-300-783 210-C

    0.02 092-030-983 072-140-983 066-040-983

    ZIP Probes for Testing Composite and OtherAttenuative Plastics

    Zero Inter face (ZIP) Probes are highly damped, lowfrequency delay line transducers designed for compositeinspection. ZIP delay lines are acoustically matched tomost composite and other plastic materials. Thiseliminates or minimizes the delay line inter face echo,significantly improving near surface resolution. The lowfrequency characteristics of ZIPs make them excellent forpenetrating thick or highly attenuative cross-sections.ZIPs can also be used on many smooth surfacedmaterials without couplant.

    .qerF)zHM(

    eziS).ni(

    TCUDORPSEDOC

    SEDOCTCUDORP

    selbaC eniLyaleD

    54.0 00.1 031-065CNB'6610-C

    170-D

    5.1 005. 131-065 CNB'6210-C

    270-D

    52.2 573. 231-065 370-D

    Zero Interface Probes (ZIP)

    K-PEN Probes

  • 6Contact TransducersSingle Element Contact Transducers are longitudinal wavetransducers designed for general purpose manual ultrasonicinspection where test materials are relatively flat and smooth.Contact transducers provide high sensitivity for betterpenetration and are ruggedly constructed for extendedservice life under the roughest testing conditions.

    PFCR and PFCS Style ContactsThe Protective Face Combination transducers are designedto allow one basic transducer to be used with three differenttypes of protective face: membrane, wear cap, or delay line. Allmodels have BNC connectors, PFCR are right angle mount andPFCS are top-mount.

    Style PM Kit includes a knurled ring, gland nut, wrench, 12membranes, and a 2 oz. bottle of couplant (transducer not included).

    Style PWC Kit includes a knurled ring, three wear caps, and a2 oz. bottle of couplant (transducer not included). This optionmay not be usable if near surface resolution is critical.

    Style PHTD Kit includes a knurled ring, either 1 or 1.5 long hightemperature delay line, and a 2 oz. bottle of couplant (transducer not included).

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    seireSammaGelytSRCFP

    seireSammaGelytSSCFP

    seireSammaGelytSRCFP

    seireSammaGelytSSCFP

    0.1

    005. 042-142 062-142

    5.3

    005. 042-342 062-342

    057. 042-152 062-152 057. 042-352 062-352

    00.1 042-162 062-162 00.1 042-362 062-362

    521.1 042-172 062-172

    52.2

    005. 042-242 062-242

    0.5

    005. 042-442 062-442

    057. 042-252 062-252 057. 042-452 062-452

    00.1 042-262 062-262 00.1 042-462 062-462

    521.1 042-272 062-272

    Protective Face Combination TransducersPFCR / PFCS Style

    Protective Face Option KitsPFCR / PFCS

    * High Temp (PHTD) delay line: maximum temperature 400F,maximum contact time 10 seconds; cool to ambient before reuse.

    tiKelytS

    SEDOCTCUDORP

    retemaiDtnemelErecudsnarT

    "005. "057. "00.1 "521.1

    MP 021-KP 041-KP 061-KP 081-KP

    CWP 022-KP 042-KP 062-KP 082-KP

    *)yaleD"1(DTHP 023-KP 043-KP 063-KP 083-KP

    *)yaleD"5.1(DTHP 024-KP 044-KP 064-KP 084-KP

    AccessoriesPFCR / PFCSSEDOCTCUDORP

    retemaiDtnemelErecudsnarT

    "005. "057. "00.1 "521.1

    senarbmeMerapS.scp21fo.gkP 020-MP 120-MP 220-MP 320-MP

    spacraeWerapS.scp21fo.gkP 321-CP 221-CP 121-CP 021-CP

    *eniLyaleD.pmeT-iHgnoL"0.1

    720-DP 130-DP 530-DP 930-DP

    *eniLyaleD.pmeT-iHgnoL"5.1

    920-DP 330-DP 730-DP 140-DP

    elbaCCNB'6 610-C

    &paCraeW,enarbmeMtnalpuoCeniLyaleD 047-DX

    tnemelEretemaiD

    A B C

    005. 57. 02.1 49.

    057. 00.1 02.1 91.1

    000.1 52.1 02.1 44.1

    521.1 83.1 53.1 75.1

  • 7.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    seireSammaGsenarbmeM

    nezod1seirosseccA seireSammaG

    senarbmeMnezod1

    seirosseccA

    0.1

    005.RCMP-142-142SCMP-162-142

    020-MP

    selbaCCNB'6610-C

    OMEL'6810-C

    enarbmeMtnalpuoC

    047-DX

    5.3

    005.RCMP-142-342SCMP-162-342

    020-MP

    selbaCCNB'6610-C

    OMEL'6810-C

    enarbmeMtnalpuoC

    047-DX

    057.RCMP-142-152SCMP-162-152

    120-MP 057.RCMP-142-352SCMP-162-352

    120-MP

    00.1RCMP-142-162SCMP-162-162

    220-MP 00.1RCMP-142-362SCMP-162-362

    220-MP

    521.1RCMP-142-172SCMP-162-172

    320-MP

    52.2

    005.RCMP-142-242SCMP-162-242

    020-MP

    0.5

    005.RCMP-142-442SCMP-162-442

    020-MP

    057.RCMP-142-252SCMP-162-252

    120-MP 057.RCMP-142-452SCMP-162-452

    120-MP

    00.1RCMP-142-262SCMP-162-262

    220-MP 00.1RCMP-142-462SCMP-162-462

    220-MP

    521.1RCMP-142-272SCMP-162-272

    320-MP

    Protective Membrane TransducersPMCR/PMCS Style

    Contact TransducersSingle Element Contact Transducers are longitudinal wave transducers designed for general purposemanual ultrasonic inspection where test materials are relatively flat and smooth. Contact transducersprovide high sensitivity for better penetration and are ruggedly constructed for extended service lifeunder the roughest testing conditions.

    tnemelEretemaiD

    A B

    005. 31.1 57.1

    057. 14.1 57.1

    000.1 36.1 57.1

    521.1 36.1 57.1

    PMCR and PMCS Style ContactsProtective Membrane Contact Transducers areexcellent for coupling to rough or uneven sur faces.The membrane will conform to surfaceirregularities providing better coupling to the testmaterial. PMCR and PMCS Style contacts aredesigned for quick, easy membrane replacementand have color-coded grips identifying transducerfrequency. The PMCR Style has right angle BNCconnectors while the PMCS Style has straighttop-mount BNC connectors.

  • 8tnemelEretemaiD

    A B

    005. 0.1 21.1

    057. 52.1 21.1

    000.1 05.1 21.1

    Protective Wear Cap/Delay Line TransducersPWCCR/PWCCS

    Contact TransducersSingle Element Contact Transducers are longitudinal wave transducers designed for general purposemanual ultrasonic inspection where test materials are relatively flat and smooth. Contact transducersprovide high sensitivity for better penetration and are ruggedly constructed for extended service lifeunder the roughest testing conditions.

    PWCCR and PWCCS Style Contacts

    Protective Wear Cap Contact Transducers haveexpendable wear caps which are easily replacedwhen worn. This means unlimited economy whenthe job calls for scrubbing which would normallydestroy a standard contact probe. The PWCCRStyle has right angle mounted BNC connectorswhile the PWCCS Style has straight top-mount BNCconnectors. High temperature delay lines are alsoavailable for applications to 400F.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    ammaGseireS

    paCraeWtiK.cp01

    yaleDTH*tiKeniL seirosseccA

    ammaGseireS

    paCraeWtiK.cp01

    yaleDTH*tiKeniL seirosseccA

    0.1

    005.RCCWP-052-142SCCWP-072-142 122-CP

    "1-050-KP"5.1-060-KP

    selbaC

    CNB'6610-C

    OMEL'6810-C

    paCraeWtnalpuoC

    047-DX

    5.3

    005.RCCWP-052-342SCCWP-072-342 122-CP

    "1-050-KP"5.1-060-KP

    selbaC

    CNB'6610-C

    OMEL'6810-C

    paCraeWtnalpuoC

    047-DX

    057.RCCWP-052-152SCCWP-072-152 142-CP

    "1-070-KP"5.1-080-KP 057.

    RCCWP-052-352SCCWP-072-352 142-CP

    "1-070-KP"5.1-080-KP

    00.1RCCWP-052-162SCCWP-072-162 162-CP

    "1-090-KP"5.1-001-KP 00.1

    RCCWP-052-362SCCWP-072-362 162-CP

    "1-090-KP"5.1-001-KP

    52.2

    005.RCCWP-052-242SCCWP-072-242 122-CP

    "1-050-KP"5.1-060-KP

    0.5

    005.RCCWP-052-442SCCWP-072-442 122-CP

    "1-050-KP"5.1-060-KP

    057.RCCWP-052-252SCCWP-072-252 142-CP

    "1-070-KP"5.1-080-KP 057.

    RCCWP-052-452SCCWP-072-452 142-CP

    "1-070-KP"5.1-080-KP

    00.1RCCWP-052-262SCCWP-072-262 162-CP

    "1-090-KP"5.1-001-KP 00.1

    RCCWP-052-462SCCWP-072-462 162-CP

    "1-090-KP"5.1-001-KP

    * High Temp (HT) Delay Line: maximum temperature 400F, maximum contact time 10 seconds; cool to ambient before reuse.

  • 9SWS and AWS Style Angle Beam, Gamma Series

    SWS and AWS Style Angle Beam Transducers are designedto fit on removable wedges. Refracted shear wave anglesmay be specified as required. The AWS series aredesigned to meet or exceed all of the requirementsoutlined in AWS Structural Welding Code D1.1. AllSWS and AWS transducers utilize captive screws forfastening the probe to the wedge and have top-mountBNC connectors. High temperature wedges are fortemperatures up to 400 F.

    Angle Beam TransducersAngle Beam Transducers are single or dual elementtransducers designed for weld inspection or flawdetection where flaws have an angular orientationwith respect to the material surface. Weldinspections are performed using shear wavesrefracted from a longitudinal wave by means of alucite wedge. Lucite wedges are designed toproduce shear waves of a particular angle in aspecified material with minimal wedge noise.

    tnemelEeziS

    A B C D

    .aid05. 27. 0.1 57. 18.

    0.1x05. 527. 15.1 57. 13.1

    0.1x57. 00.1 5.1 57. 13.1

    .aid0.1 22.1 56.1 57. 83.1

    526.x526. 527. 52.1 57. 00.1

    057.x526. 527. 52.1 57. 00.1

    057.x057. 58. 52.1 57. 00.1

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    ammaGseireS

    dradnatSegdeW

    pmeT-iH*egdeW seirosseccA

    ammaGseireS

    dradnatSegdeW

    pmeT-iH*egdeW seirosseccA

    5. aiD0.1 006-062

    54120-W06220-W07320-W09520-W

    54180-W06280-W07380-W

    selbaC

    CNB'6610-C

    OMEL'6810-C

    egdeWtnalpuoC

    047-DX

    52.2SWAseireS

    36.x36. 306-29254401-W06501-W07601-W

    selbaC

    CNB'6610-C

    OMEL'6810-C

    egdeWtnalpuoC

    047-DX

    0.1

    aiD5. 006-142

    54900-W06010-W07110-W09310-W

    54670-W06770-W07870-W

    57.x36. 106-292

    54401-W06501-W07601-W

    1x5. 006-192

    54510-W06610-W07710-W09910-W

    54070-W06680-W07170-W 57.x57. 406-292

    54401-W06501-W07601-W

    1x57. 506-192

    54150-W06250-W07-350-W09450-W

    5.3

    aiD5. 006-342

    54900-W06010-W07110-W09310-W

    54670-W06770-W07870-W

    aiD0.1 006-162

    54120-W06220-W07320-W09520-W

    54180-W06280-W07380-W

    1x5. 006-392

    54510-W06610-W07710-W09910-W

    54070-W06680-W07170-W

    52.2

    aiD5. 006-242

    54900-W06010-W07110-W09310-W

    54670-W06770-W07870-W 1x57. 506-392

    54150-W06250-W07-350-W09450-W

    1x5. 006-292

    54510-W06610-W07710-W09910-W

    54070-W06680-W07170-W

    aiD0.1 006-362

    54120-W06220-W07320-W09520-W

    54180-W06280-W07380-W

    1x57. 506-292

    54150-W06250-W07350-W09450-W

    0.5

    aiD5. 006-442

    54900-W06010-W07110-W09310-W

    54670-W06770-W07870-W

    aiD0.1 006-262

    54120-W06220-W07320-W09520-W

    54180-W06280-W07380-W

    1x5. 006-492

    54510-W06610-W07710-W09910-W

    54070-W06680-W07170-W

    1x57. 506-492

    54150-W06250-W07350-W09450-W

    aiD0.1 006-462

    54120-W06220-W07320-W09520-W

    54180-W06280-W07380-W

    Standard Angle BeamSWS and AWS Styles, Gamma Series

    * Duty Cycle: at 400F, maximum contact time is 10 seconds; cool toambient before reuse.Note: Standard wedge angles are specified for carbon steel.

  • 10

    Angle Beam TransducersAngle Beam Transducers are single or dual elementtransducers designed for weld inspection or flaw detectionwhere flaws have an angular orientation with respect tothe material surface. Weld inspections are performedusing shear waves refracted from a longitudinal wave bymeans of a lucite wedge. Lucite wedges are designed toproduce shear waves of a particular angle in a specifiedmaterial with minimal wedge noise.

    SWS and AWS Style Angle Beam, Benchmark SeriesBenchmark series SWS and AWS Style Angle Beam Transducers feature proprietary BENCHMARKCOMPOSITE active elements. They are available in the same range of sizes and fit the sameremovable wedges as the Gamma series. Benchmark series offer a superior combination ofsensitivity, resolution, and penetration for punching through highly attenuative materials. They areespecially beneficial when signal to noise ratio is a problem, for example coarse grain materials andfiber reinforced composites. The AWS models meet all requirements of Structural Welding Code D1.1.

    SEDOCTCUDORP SEDOCTCUDORP

    .qerF)zHM(

    eziS).ni(

    kramhcneBseireS

    dradnatSegdeW

    seirosseccA.qerF)zHM(

    eziS).ni(

    kramhcneBseireS

    dradnatSegdeW

    seirosseccA

    0.1

    aiD5. 006-148

    54900-W06010-W07110-W09310-W

    selbaC

    CNB'6610-C

    OMEL'6810-C

    egdeWtnalpuoC

    047-DX

    5.3

    aiD5. 006-348

    54900-W06010-W07110-W09310-W

    selbaC

    CNB'6610-C

    OMEL'6810-C

    egdeWtnalpuoC

    047-DX

    1x5. 006-198

    54510-W06610-W07710-W09910-W

    1x5. 006-398

    54510-W06610-W07710-W09910-W

    1x57. 506-198

    54150-W06250-W07-350-W09450-W

    1x57. 506-398

    54150-W06250-W07-350-W09450-W

    aiD0.1 006-168

    54120-W06220-W07320-W09520-W

    aiD0.1 006-368

    54120-W06220-W07320-W09520-W

    52.2

    aiD5. 006-248

    54900-W06010-W07110-W09310-W

    0.5

    aiD5. 006-448

    54900-W06010-W07110-W09310-W

    1x5. 006-298

    54510-W06610-W07710-W09910-W

    . 1x5006-498

    54510-W06610-W07710-W09910-W

    1x57. 506-298

    54150-W06250-W07350-W09450-W

    1x57. 506-498

    54150-W06250-W07350-W09450-W

    aiD0.1 006-268

    54120-W06220-W07320-W09520-W

    aiD0.1 006-468 54120-W06220-W07330-W09520-W

    52.2SWAseireS

    36.x36. 306-29854401-W06501-W07601-W

    57.x36. 106-29854401-W06501-W07601-W

    57.x57. 406-29854401-W06501-W07601-W

    Standard Angle BeamSWS and AWS Styles, Benchmark Series

    Note: Standard wedge angles are specified for carbon steel.

  • 11

    Angle Beam TransducersAngle Beam Transducers are single or dual element transducersdesigned for weld inspection or flaw detection where flaws havean angular orientation with respect to the material surface.Weld inspections are performed using shear waves refractedfrom a longitudinal wave by means of a lucite wedge. Lucitewedges are designed to produce shear waves of a particularangle in a specified material with minimal wedge noise.

    MSW-QC Style Angle Beam, Gamma Series

    MSW-QC Style are miniature angle beam trans-ducers thatscrew directly into our Quick Change Lucite wedges. AllMSW-QC transducers have top-mount Microdot connectors.Gamma series utilize conventional monolithic ceramicelements and are recommended for regular inspection ofnon-attenuative materials.10.0 MHz MSW-QCtransducers are availableonly in Gamma series.

    "52.egdeWelbaecalpeR "573.egdeWelbaecalpeR "05.egdeWelbaecalpeR

    egdeWelgnA

    A B C D EegdeWelgnA

    A B C D EegdeWelgnA

    A B C D E

    54060709

    54.54.54.54.

    57.48.00.159.

    73.44.05.05.

    14.14.14.14.

    74.74.74.74.

    54060709

    55.55.55.55.

    98.40.191.151.1

    74.55.85.16.

    65.65.65.65.

    05.05.05.05.

    54060709

    07.07.07.07.

    50.142.114.193.1

    55.46.86.37.

    07.07.07.07.

    26.26.26.26.

    Note: Standard wedge angles are specified for carbon steel.

    Miniature Angle Beam TransducersMSW-QC Style

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    ammaGseireS

    dradnatSegdeW seirosseccA

    ammaGseireS

    dradnatSegdeW seirosseccA

    0.1 005. 095-142

    03012-W54112-W06212-W07312-W09412-W

    selbaC

    CNB'6210-C

    OMEL'6220-C

    egdeWtnalpuoC

    047-DX

    5.3.tnoc 005. 095-342

    03012-W54112-W06212-W07312-W09412-W

    selbaC

    CNB'6210-C

    OMEL'6220-C

    egdeWtnalpuoC

    047-DX

    5.1

    573. 095-132

    03022-W54122-W06222-W07322-W09422-W

    0.5

    052. 095-422

    03002-W54102-W06202-W07302-W09402-W

    005. 595-142

    03012-W54112-W06212-W07312-W09412-W

    573. 095-432

    03022-W54122-W06222-W07322-W09422-W

    52.2

    052. 095-222

    03002-W54102-W06202-W07302-W09402-W

    005. 095-442

    03012-W54112-W06212-W07312-W09412-W

    573. 095-232

    03022-W54122-W06222-W07322-W09422-W

    01

    052. 095-622

    03002-W54102-W06202-W07302-W09402-W

    005. 095-242

    03012-W54112-W06212-W07312-W09412-W

    573. 095-632

    03022-W54122-W06222-W07322-W09422-W

    5.3

    052. 095-322

    03002-W54102-W06202-W07302-W09402-W

    005. 095-642

    03012-W54112-W06212-W07312-W09412-W

    573. 095-332

    03022-W54122-W06222-W07322-W09422-W

  • 12

    Angle Beam TransducersAngle Beam Transducers are single or dual element transducersdesigned for weld inspection or flaw detection where flaws havean angular orientation with respect to the material surface.Weld inspections are performed using shear waves refractedfrom a longitudinal wave by means of a lucite wedge. Lucitewedges are designed to produce shear waves of a particularangle in a specified material with minimal wedge noise.

    Note: Standard wedge angles are specified for carbon steel.

    MSW-QC Style Angle Beam, Benchmark and Alpha Series

    Benchmark and Alpha series MSW-QC Miniature Angle Beam Transducers are available inthe same range of sizes and fit the same standard Quick Change" wedges as the Gamma series.Their one-piece stainless steel case insures long service life. All MSW-QC probes are color coded byfrequency and have top mounted Microdot connectors.

    Benchmark series probes feature proprietary BENCHMARK COMPOSITE active elements. They offer asuperior combination of sensitivity, resolution, and penetration for punching through highly attenuativematerials. They are especially beneficial when signal to noise ratio is a problem, for example coarsegrain materials and fiber reinforced composites. Alpha series MSW-QC probes are made with highlydamped monolithic ceramic elements and are recommended when very short pulse lengths arerequired for axial resolution.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    kramhcneBseireS

    ahplAseireS

    dradnatSegdeW seirosseccA

    kramhcneBseireS

    ahplAseireS

    dradnatSegdeW seirosseccA

    0.1 005. 195-142 195-141

    03012-W54112-W06212-W07312-W09412-W

    selbaC

    CNB'6210-C

    OMEL'6220-C

    egdeWtnalpuoC

    047-DX

    5.3.tnoc 005. 195-342 195-341

    03012-W54112-W06212-W07312-W09412-W

    selbaC

    CNB'6210-C

    OMEL'6220-C

    egdeWtnalpuoC

    047-DX

    5.1

    573. 695-132 695-131

    03022-W54122-W06222-W07322-W09422-W

    0.5

    052. 195-422 195-421

    03002-W54102-W06202-W07302-W09402-W

    005. 695-142 695-141

    03012-W54112-W06212-W07312-W09412-W

    573. 195-432 195-431

    03022-W54122-W06222-W07322-W09422-W

    52.2

    052. 195-222 195-221

    03002-W54102-W06202-W07302-W09402-W

    005. 195-442 195-441

    03012-W54112-W06212-W07312-W09412-W

    573. 195-232 195-231

    03022-W54122-W06222-W07322-W09422-W

    5.7

    052. 195-522 195-521

    03002-W54102-W06202-W07302-W09402-W

    005. 195-242 195-241

    03012-W54112-W06212-W07312-W09412-W

    573. 195-532 195-531

    03022-W54122-W06222-W07322-W09422-W

    5.3

    052. 195-322 195-321

    03002-W54102-W06202-W07302-W09402-W

    005. 195-542 195-541

    03012-W54112-W06212-W07312-W09412-W

    573. 195-332 195-331

    03022-W54122-W06222-W07322-W09422-W

    Miniature Angle Beam TransducersMSW-QC Style

  • 13

    Angle Beam TransducersAngle Beam Transducers are single or dual elementtransducers designed for weld inspection or flawdetection where flaws have an angular orientationwith respect to the material sur face. Weld inspectionsare per formed using shear waves refracted from alongitudinal wave by means of a lucite wedge. Lucite wedgesare designed to produce shear waves of a particular anglein a specified material with minimal wedge noise.

    "52.egdeWelbaecalpeR "05.egdeWelbaecalpeR

    elgnA A B C D E F elgnA A B C D E F

    54 74. 06. 03. 13. 84. 43. 54 37. 69. 24. 65. 37. 05.

    06 74. 56. 53. 13. 84. 43. 06 37. 80.1 05. 65. 37. 05.

    07 74. 07. 83. 13. 84. 43. 07 37. 61.1 45. 65. 37. 05.

    09 74. 09. 83. 13. 84. 43. 09 37. 65.1 85. 65. 37. 05.

    MSWS Style Angle BeamMSWS Angle Beam Transducers are designed to fitremovable lucite wedges. Refracted shear wave anglesmay be specified as required. All MSWS transducershave captive screws for fastening the probe to the wedgeand are fitted with Microdot connectors. High temperaturewedges are for use at temperatures up to 400F.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    ammaGseireS

    dradnatSegdew

    pmeT-iH*egdeW

    seirosseccAammaGseireS

    dradnatSegdeW

    pmeT-H*egdeW

    seirosseccA

    0.1 005. 085-142

    54040-W06240-W07440-W08640-W09840-W

    54850-W06950-W07060-W

    selbaCCNB'6210-C

    OMEL'6220-C

    egdeWtnalpuoC

    047-DX

    0.5

    052. 085-422

    54820-W06030-W07230-W08430-W09630-W

    54550-W06650-W07750-W

    selbaCCNB'6210-C

    OMEL'6220-C

    egdeWtnalpuoC

    047-DX

    52.2

    052. 085-222

    54820-W06030-W07230-W08430-W09630-W

    54550-W06650-W07750-W 005. 085-442

    54040-W06240-W07440-W08640-W09840-W

    54850-W06950-W07060-W

    005. 085-242

    54040-W06240-W07440-W08640-W09840-W

    54850-W06950-W07060-W

    0.01

    052. 085-622

    54820-W06030-W07230-W08430-W09630-W

    54550-W06650-W07750-W

    5.3

    052. 085-322

    54820-W06030-W07230-W08430-W09630-W

    54550-W06650-W07750-W 005. 085-642

    54040-W06240-W07440-W08640-W09840-W

    54850-W06950-W07060-W

    005. 085-342

    54040-W06240-W07440-W08640-W09840-W

    54850-W06950-W07060-W

    Miniature Angle Beam TransducersMSWS Style

  • 14

    snoisnemiDegdeW

    elgnA A B C D E F

    54 13. 52. 12. 91. 32. 82.

    06 13. 24. 12. 91. 32. 82.

    07 13. 24. 12. 91. 32. 82.

    09 13. 27. 43. 91. 32. 82.

    Angle Beam Transducers

    tnemelEsnoisnemiD

    A B C

    781.x781. 23. 07. 75.

    52.x52. 05. 0.1 55.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    54 06 07 09 seirosseccA

    52.2781.x781. 046-292 146-292 246-292 346-292

    selbaC

    CNB'6210-C

    OMEL'6220-C

    052.x052. 026-292 126-292 226-292 326-292

    0.5781.x781. 046-492 146-492 246-492 346-492

    052.x052. 026-492 126-492 226-492 326-492

    01781.x781. 046-692 146-692 246-692 346-692

    052.x052. 026-692 126-692 226-692 326-692

    Fingertip Potted Angle Beam TransducersABFP Style

    SMSWS Style Angle BeamSMSWS Angle Beam Transducers are subminiature transducers designed tofit removable lucite wedges. Refracted shear wave angles may be specifiedas required. All SMSWS transducers have standard screws for fastening theprobe to the wedge and have top-mount miniature Microdot connectors.

    Note: Part numbers above are for carbon steel. For aluminum, specify frequency, size,and refracted angle in aluminum.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    ammaGseireS

    dradnatSegdeW

    seirosseccA

    52.2 521. 585-212

    54021-W06121-W07221-W09321-W

    elbaCCNB'6740-C

    egdeWtnalpuoC

    047-DX

    0.5 521. 585-412

    54021-W06121-W07221-W09321-W

    0.01 521. 585-612

    54021-W06121-W07221-W09321-W

    Subminiature Angle BeamSMSWS Style

    Note: Standard wedge angles are specified for carbon steel.

    Angle Beam Transducers are single or dual element transducersdesigned for weld inspection or flaw detection where flaws have anangular orientation with respect to the material surface. Weldinspections are per formed using shear waves refracted from alongitudinal wave by means of a lucite wedge. Lucite wedges aredesigned to produce shear waves of a particular angle in a specifiedmaterial with minimal wedge noise.

    ABFP Style Angle BeamABFP Style, fingertip, fixed angle, shear wave transducers are available in standard angles forinspecting steel and aluminum. Custom angles for other materials may be special ordered. Their smallsize makes them ideal for weld inspection in restricted access areas. All ABFP Transducers areequipped with right angle Microdot connectors. Top mounted connectors may be special ordered.

  • 15

    Dual Element TransducersDual Element Contact Transducers are longitudinalwave transducers with a split element; one halffunctions as a transmitter while the other functions asa receiver. Each half-element is angled slightly towardthe other forming the roof angle. This roof angleeffectively focuses the sound beam. These trans-ducers are excellent for thin range flaw detection andthickness gauging. Because they have a discretetransmitter and receiver, better signal to noise ratiosare achieved compared to single element transducers.

    ADP, RC, and FDU Style Dual Element

    Dual Element Transducers are for general flawdetection and thickness gauging on materials withirregular or pitted surfaces. The ADP and RC modelsare color coded for quick frequency identification. Thelow profile ADP model has a potted BNC cable. The RCDual models have a 4-pin LEMO connector whichallows for quick and easy cable replacement. All FDUmodels have mini Microdot threaded connectors. Allmodels may be contoured to fit ID and OD curvatures.

    tnemelEretemaiD

    A B C

    052. 05. 46. 63.

    573. 36. 46. 74.

    005. 57. 86. 06.

    qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    lauDPDA *lauDCR lauDUDF lauDPDA *lauDCR lauDUDF

    52.2

    052. 007-222 186-222 086-222

    0.5

    052. 007-422 186-422 086-422

    573. 007-232 186-232 086-232 573. 007-432 186-432 086-432

    005. 007-242 186-242 005. 007-442 186-442

    5.3

    052. 007-322 186-322 086-322 5.7 573. 007-531

    573. 007-332 186-332 086-332

    005. 007-342 186-342

    tnemelEretemaiD

    A B

    052. 83. 05.

    573. 05. 05.

    ADP/RC

    Fingertip Dual Element TransducersADP/RC/FDU Styles

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    ledoMammaGseireS

    seirosseccA

    0.5

    052. A004TH 067-422

    selbaCCNB'6

    201-C:dradnatS101-C:deromrA

    573. V065ABK 032-445elbaCCNB'6760-C

    *Duty Cycle: KBA560V750F, maximum contact time is 10 seconds;HT400A1000F, maximum contact time is 5 seconds; cool toambient before reuse.

    HT400A

    KBA560V

    High Temperature Transducers*

    HT400A and KBA560V Style HighTemperature Dual Element Transducers

    HT400A and KBA560V models areavailable with replaceable BNC cables andcan be used for both flaw detectionand thickness gauging applications.Model HT400A can be usedintermittently on materials up to1000 F. Model KBA560V canbe used intermittently onmaterials up to 750F.

    FDU

    * Standard BNC Cable (C-088) or Heavy Duty BNC Cable (C-089) sold separately Standard BNC Cable (C-014) sold separately

  • 16

    Dual Element TransducersDual Element Contact Transducers are longitudinal wave transducerswith a split element; one half functions as a transmitter while theother functions as a receiver. Each half-element is angled slightlytoward the other forming the roof angle. This roof angleeffectively focuses the sound beam. These transducers are excellentfor thin range flaw detection and thickness gauging. Because theyhave a discrete transmitter and receiver, better signal to noise ratiosare achieved compared to single element transducers.

    DU Style Dual Element

    DU Dual Element Transducers with replaceabledelays are excellent general-purpose probes forapplications with flat or curved surfaces. HighTemperature delays are also available forinspections at temperatures up to 400F. All DUtransducers have standard Microdotconnectors for easy replacement.

    tnemelEeziS

    A B C

    005.x005. 57. 58. 87.

    00.1x005. 83.1 29. 87.

    DU-F Style Dual Element, Benchmark SeriesBenchmark series DU-F Style Dual Element Transducersfeature proprietary BENCHMARK COMPOSITE activeelements. Benchmark series offer a superiorcombination of sensitivity, resolution, andpenetration for punching through highlyattenuative materials. They are especiallybeneficial when signal to noise ratio is aproblem, for example coarse grain materialsand fiber reinforced composites. Closetolerance, integral delays assure consistentper formance.

    FASTTM Probes for Rapid Manual Weld Inspection

    Benchmark series FASTTM Probes are dual, high angle,longitudinal wave probes with proprietaryBENCHMARK COMPOSITE elements. They areprimarily for inspection using the FASTTM methoddeveloped by SPIN (LLC). FASTTM high speed,manual weld scanning can reduce inspectioncosts for fabrication shops, field weldingorganizations,or any industry that per forms in-service NDE of components. For a detailedProduct Bulletin, contact our sales department.

    * Duty Cycle: at 400F, maximum contact time is 10 seconds; cool toambient before reuse.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    ammaGseireS

    yaleDteS

    yaleDTH*teS

    seirosseccA

    0.15.x5. 057-192 026-SD 027-SD

    elbaCCNB'6420-C

    tnalpuoC047-DX

    1x5. 047-192 046-SD 047-SD

    52.25.x5. 057-292 026-SD 027-SD

    1x5. 047-292 046-SD 047-SD

    0.55.x5. 057-492 026-SD 027-SD

    1x5. 047-492 066-SD 067-SD

    Standard Dual Element TransducersDU Style

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    kramhcneBseireS

    seirosseccA

    52.25.x5. 157-292

    elbaCCNB'6420-C

    1x5. 147-292

    0.55.x5. 157-492

    1x5. 147-492

    DU-F StyleBenchmark

    ledoM.qerF)zHM(

    lufesUhtpeD

    TCUDORPSEDOC

    1TSAF 0.5 "6.0ot"0 088-610-983

    2TSAF 0.5 "5.1ot"0 009-610-983

    3TSAF 0.5 "4ot"5.0 087-610-983

    FASTTM Probes

  • 17

    Immersion TransducersSingle Element Immersion Transducers are longitudinal wavetransducers typically used in manual, semi-automatic, andautomatic scanning systems. Scanning parts with irregular orcomplex geometries is possible because of the conformingwater path layer between the probe and the inspected material.Superior near-surface resolution can be achieved when comparedto contact transducers. Angle beam inspection is possible bysimply angling the probe or search tube in relation to the partsurface. Spherical (point) or cylindrical (line) focusing can also beaccomplished using acoustically matched lenses. Focal lengthmust be specified.

    tnemelEretemaiD

    A B

    052. 36. 55.1

    573. 36. 55.1

    005. 36. 55.1

    057. 0.1 77.1

    00.1 52.1 28.1

    ISS and IS Style ImmersionISS and IS Immersion Transducers are for general ultrasonic immersion inspections requiring elementdiameters between .25 and 1.0. Available in Alpha, Gamma, and BENCHMARK COMPOSITE series,they can be focused for critical applications to improve near-surface resolution or sensitivity to smalldiscontinuities. All ISS and IS Transducers have waterproof UHF connectors. Waterproof BNCconnectors may be specialordered. Gamma Series arerecommended forapplications where highsensitivity and penetrationare required. Alpha Series(where available) aredesigned for optimumdamping and resolution.New Benchmark Series(where available), withBENCHMARK COMPOSITE

    elements, offer a superiorcombination of sensitivity,resolution, and penetrationfor punching through highlyattenuative materials.

    * Focus: S = Spherical; C = Cylindrical, N = Non-focus.Focal length must be specified. For available focallengths, see table at the end of the ImmersionTransducers section.Note: Waterproof cables are available in Accessories Section.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    sucoF*ahplAseireS

    ammaGseireS

    kramhcneBseireS

    sucoF*ahplAseireS

    ammaGseireS

    kramhcneBseireS

    0.1

    052.SCN

    082-122092-122003-122

    0.5

    052.SCN

    082-421092-421003-421

    082-422092-422003-422 003-428

    573.SCN

    082-132092-132003-132

    573.SCN

    082-431092-431003-431

    082-432092-432003-432

    082-438092-438003-438

    005.SCN

    082-142092-142003-142

    005.SCN

    082-441092-441003-441

    082-442092-442003-442

    082-448092-448003-448

    057.SCN

    063-152073-152083-152

    057.SCN

    063-451073-451083-451

    063-452073-452083-452

    063-458073-458083-458

    00.1SCN

    063-162073-162083-162

    063-168073-168083-168

    00.1SCN

    063-461073-461083-461

    063-462073-462083-462

    063-468073-468083-468

    52.2

    052.SCN

    082-221092-221003-221

    082-222092-222003-222 003-228

    01

    052.SCN

    082-621092-621003-621

    082-622092-622003-622

    573.SCN

    082-231092-231003-231

    082-232092-232003-232 003-238

    573.SCN

    082-631092-631003-631

    082-632092-632003-632

    005.SCN

    082-241092-241003-241

    082-242092-242003-242

    082-248092-248003-248

    005.SCN

    082-641092-641003-641

    082-642092-642003-642

    057.SCN

    063-251073-251083-251

    063-252073-252083-252

    063-258073-258083-258

    057.SCN

    063-651073-651083-651

    063-652073-652083-652

    00.1SCN

    063-261073-261083-261

    063-262073-262083-262

    063-268073-268083-268

    51

    052.SCN

    082-721092-721003-721

    5.3

    052.SCN

    082-321092-321003-321

    082-322092-322003-322 003-328

    052. S"5.1 203-721 )001-CTT(

    573.SCN

    082-331092-331003-331

    082-332092-332003-332

    082-338092-338003-338

    573.SCN

    082-731092-731003-731

    005.SCN

    082-341092-341003-341

    082-342092-342003-342

    082-348092-348003-348

    005.SCN

    082-741092-741003-741

    057.SCN

    063-351073-351083-351

    063-352073-352083-352

    063-358073-358083-358

    52 052.SCN

    082-921092-921003-921

    00.1SCN

    063-361073-361083-361

    063-362073-362083-362

    063-368073-368083-368

    Immersion TransducersISS and IS Styles

  • 18

    Immersion TransducersSingle Element Immersion Transducers are longitudinal wave transducers typically used inmanual, semi-automatic, and automatic scanning systems. Scanning parts with irregular orcomplex geometries is possible because of the conforming water path layer between the probeand the inspected material. Superior near-surface resolution can be achieved when compared tocontact transducers. Angle beam inspection is possible by simply angling the probe or searchtube in relation to the part surface. Spherical (point) or cylindrical (line) focusing can also beaccomplished using acoustically matched lenses. Focal length must be specified.

    IPS Style ImmersionIPS Immersion Transducers with small diameter cases are designed for immersionapplications where transducer size limitations exist. The Alpha series are designed formaximum bandwidth and resolution capabilities. The Gamma series are for increased sensitivity andpenetration. All IPS Transducers have Microdot connectors.For best results the connector should besealed with a non-water soluble grease.

    IR Style Immersion

    IR Immersion Transducers are used where.25 to .5 diameter probes are desired,but where space constraints exist thatprohibit the use of standard ISS Styletransducers. IR Style transducers have aright angle mounted UHF connector andwill fit into a 1.5 cubic inch area. The IR isavailable in both the Alpha and Gammaseries and can be focused forcritical applications toimprove near-surfaceresolution or sensitivityto small discontinuities.

    tnemelEretemaiD

    A B

    521. 83. 54.1

    052. 83. 54.1

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    sucoF*ahplAseireS

    ammaGseireS

    sucoF*ahplAseireS

    ammaGseireS

    0.1

    052.NCS

    024-122014-122004-122

    5.3

    052.NCS

    024-321014-321004-321

    024-322014-322004-322

    573.NCS

    024-132014-132004-132

    573.NCS

    024-331014-331004-331

    024-332014-332004-332

    005.NCS

    024-142014-142004-142

    005.NCS

    024-341014-341004-341

    024-342014-342004-342

    52.2

    052.NCS

    024-221014-221004-221

    024-222014-222004-222

    0.5

    052.NCS

    024-421014-421004-421

    024-422014-422004-422

    573.NCS

    024-231014-231004-231

    024-232014-232004-232

    573.NCS

    024-431014-431004-431

    024-432014-432004-432

    005.NCS

    024-241014-241004-241

    024-242014-242004-242

    005.NCS

    024-441014-441004-441

    024-442014-442004-442

    tnemelEretemaiD

    A B C

    ,573.,052.005.

    57. 49. 57.

    Immersion TransducersIR Style

    * Focus: S = Spherical; C = Cylindrical; N = Non-focus. Focal length must be specified.For available focal lengths, see table at the end of the Immersion Transducers section.Note: Waterproof cables are available in Accessories Section.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    sucoF*ahplAseireS

    ammaGseireS

    seirosseccA sucoF*ahplAseireS

    ammaGseires

    seirosseccA

    0.1 052.SCN

    023-122033-122043-122

    elbaC

    CNB'6210-C

    01 052.SCN

    023-621033-621043-621

    023-622033-622043-622

    elbaC

    CNB'6210-C

    52.2 052.SCN

    023-221033-221043-221

    023-222033-222043-222

    51

    521.SCN

    023-711033-711043-711

    5.3 052.SCN

    023-321033-321043-321

    023-322033-322043-322

    052.SCN

    023-721033-721043-721

    0.5 052.SCN

    023-421033-421043-421

    023-422033-422043-422

    22 521.SCN

    023-811033-811043-811

    52 052.SCN

    023-921033-921043-921

    Immersion TransducersIPS Style

    * Focus: S = Spherical; C = Cylindrical; N = Non-focus. Focal length must be specified. For available focallengths, see table at the end of the Immersion Transducers section.

    .qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP.qerF)zHM(

    eziS).ni(

    SEDOCTCUDORP

    sucoF*ahplAseireS

    ammaGseireS

    seirosseccA sucoF*ahplAseireS

    ammaGseires

    seirosseccA

    0.1 052.SCN

    023-122033-122043-122

    elbaC

    CNB'6210-C

    01 052.SCN

    023-621033-621043-621

    023-622033-622043-622

    elbaC

    CNB'6210-C

    52.2 052.SCN

    023-221033-221043-221

    023-222033-222043-222

    51

    521.SCN

    023-711033-711043-711

    5.3 052.SCN

    023-321033-321043-321

    023-322033-322043-322

    052.SCN

    023-721033-721043-721

    0.5 052.SCN

    023-421033-421043-421

    023-422033-422043-422

    22 521.SCN

    023-811033-811043-811

    52 052.SCN

    023-921033-921043-921

  • 19

    Immersion TransducersSingle Element Immersion Transducers are longitudinal wavetransducers typically used in manual, semi-automatic, andautomatic scanning systems. Scanning parts with irregular orcomplex geometries is possible because of the conforming waterpath layer between the probe and the inspected material.Superior near-surface resolution can be achieved when comparedto contact transducers. Angle beam inspection is possible bysimply angling the probe or search tube in relation to the partsurface. Spherical or cylindrical focusing can also be accomplishedusing acoustically matched lenses. Focal length must be specified.

    Velocity System Immersion TransducersThese transducers are specifically designed for use with throughtransmission Krautkramer Velocity Systems. These transducersare available in either the ISS Style or IR Style housing and areprovided with standard waterproof UHF connectors.

    Velocity System ImmersionTransducers ISS/IR Styles

    ISS

    IR

    Immersion Transducer Focal Lengths

    N = (Dia.)2 (Freq.) 4 Velocity

    The following table lists the near field lengthsand minimum and maximum practical focallengths in water expressed in inches. To findthe approximate near field length in steel,divide all N values by 4.

    ycneuqerF)zHM(

    )sehcnI(retemaiDtnemelE

    0.1 57. 05. 573. 52. 521.

    0.1N

    niMxaM

    3.40.20.3

    4.25.10.2

    1.10.10.1

    52.2N

    niMxaM

    6.90.20.6

    4.55.10.4

    4.20.10.2

    4.18.8.

    6.5.5.

    5.3N

    niMxaM

    0.510.20.8

    4.85.10.6

    7.30.15.2

    1.28.5.

    9.5.5.

    0.5N

    niMxaM

    0.120.20.8

    0.215.10.8

    4.50.10.4

    0.38.0.2

    3.15.8.

    3.3.3.

    0.01N

    niMxaM

    0.425.10.8

    7.010.10.6

    0.68.5.4

    7.25.5.1

    7.3.3.

    0.51N

    niMxaM

    0.610.10.6

    0.98.0.6

    0.45.0.2

    0.13.5.

    0.52N

    niMxaM

    7.65.0.2

    7.13.0.1

    .qerF)zHM(

    SEDOCTCUDORP

    elytSSSI

    elytSRI

    0.5 103-441 124-441

    N = Near field practical focal length.Min = Minimum practical focal length.Max = Maximum practical focal length.

  • 20

    Single Element TransducersFor Use With Precision Thickness Gauges

    Precision thickness gauging transducers aresingle element, delay line and contacttransducers designed primarily for use withKrautkramer precision thickness gauges.They may also be used with most standard flawdetection instruments. A wide variety is availableto satisfy virtually any inspection requirement onmost metals and nonmetals with relativelysmooth, parallel front and back surfaces.Depending on probe selection and materialconditions, most precision gauges can measurefrom 0.005 to 15.00 inches in steel and plastic.

    snoitacificepSrecudsnarTelbitapmoCLD3LCdna3LC

    ledoM epyTrecudsnarT tcatnoCretemaiD

    lanimoNycneuqerF

    egnaRgnirusaeM)detonsselnuleets(

    edoCtcudorP

    RFD2ahplA dradnatS,yaleDgnisuoH

    .ni03.0mm6.7

    zHM51 .ni0.1ot010.0mm52ot52.0

    066-725-311

    ,A2ahplARFDiniM

    llamS,yaleDgnisuoH

    .ni91.0mm8.4

    zHM02 .ni002.0ot010.0mm5ot52.0

    556-815-311

    A112AC ,tcatnoCdradnatS

    .ni57.0mm1.91

    zHM5 .ni0.51ot080.0mm183ot2

    000-445-311

    512AC ,tcatnoCdradnatS

    .ni05.0mm7.21

    zHM5 .ni0.2ot080.0mm15ot2

    110-421-311

    F2ahplA ,tcatnoCpitegniF

    .ni83.0mm7.9

    zHM01 .ni0.01ot08.0mm452ot2

    000-625-311

    P-RFDahplA yaleD,scitsalPeniL

    .ni03.0mm6.7

    zHM22 .ni051.0ot500.0mm8.3ot31.0

    ylnoscitsalP

    166-811-311

    omeLelgnathgirottodorciM(elbac406--505-220aesunoitcennocrecudsnartdnatnemurtsniroF)rotcennocomeLthgiartsottodorciM(529-405-220aro,)rotcennoc

    snoitacificepSrecudsnarTelbitapmoC403LCdna003LC

    ledoM epyTrecudsnarT retemaiDtcatnoC lanimoNycneuqerF

    leets(egnaRgnirusaeM)detonsselnu

    edoCtcudorP

    RFD2ahplA dradnatS,yaleDgnisuoH

    .ni03.0mm6.7

    zHM51 .ni0.1ot700.0mm52ot52.0

    066-725-311

    ,A2ahplARFDiniM

    llamS,yaleDgnisuoH

    .ni91.0mm8.4

    zHM02 .ni002.0ot500.0mm5ot31

    556-815-311

    A112AC ,tcatnoCdradnatS

    .ni57.0mm1.91

    zHM5 .ni0.51ot060.0mm183ot5.1

    000-445-311

    F2ahplA ,tcatnoCpitegniF

    .ni83.0mm7.9

    zHM01 .ni0.01ot060.0mm452ot5.1

    000-625-311

    521ABK ,scitsalPtcatnoC

    .ni81.0mm6.4

    zHM02 numinim.ni010.0muminimmm52.0

    ylnoscitsalP

    600-815-311

    403LCneP-KylnO

    elytSlicnePrecudsnarT

    .ni090.ro560.mm3.2ro7.1

    zHM02 noitacilppanotnednepeDlaiceps403LCderiuqerdna

    gnittessunem

    092-030-983

    )CNBottodorciM(elbac210-041-811aesunoitcennocrecudsnarttotnemurtsniroF

    CA211

    Alpha DFR-P

    Alpha 2F

    KPen

    KBA125

    Alpha 2DFR

    Mini DFR

    CA215

  • 21

    Standard probes are readily available to satisfy a wide range of remaining wall thickness applica-tions including: high-temperature, through-coating, erosion/corrosion, thin materials, areas oflimited access, tough-to-penetrate materials (coarse-grained/nonmetals), external pitting, wear-resistance, boiler tubing, small diameter piping and tubing, and general-purpose applications.

    DIALOG Intelligent Probes are automatically recognized by the DM4 Family of instruments for quicksetup, best performance, and test documentation. The model FH2E-D-REM contains a built-inmembrane switch with no additional cable lines to send and store readings in the DM4 DLs on-board data logger at a press of the index finger of the probe hand.

    Dual Element D-Meter ProbesCompatible with the D-Meter line of ultrasonic thickness gauges.

    A B

    CD E

    F

    G

    HI

    JK

    L

    M

    N

    O

    P

    Q

    lebaL ledoM noitangiseD elbaCeborP retemaiDtcatnoCgnirusaeM

    egnaRleetSni

    egnaRpmeT edoCtcudorP

    .A E2HF pitregniF dettoP "083. "0.2-"030. F031< 500-255-311

    .B **D-E2HF pitregniF dettoP "083. "0.2-"030. F031< 700-255-311

    .C **MER-D-E2HF dneSetomeR dettoP "083. "0.2-"030. F031< 900-255-311

    .D *HF055BK pitregniF dettoP "573. "0.2-"060. F031< 100-055-311

    .E 213AD slairetaMnihT 235ABK "003. "0.1-"520. F031< 609-650-380

    .F 525ABK tnirptooFmm5 dettoP "002. "0.1-"520. F031< 200-615-311

    .G *61B213AD tnirptooFmm3 dettoP "021. "05.-"520. F031< 439-660-380

    .H 065ABK esopruPlareneG 135ABK "526. "0.8-"060. F054< 012-445-311

    .I **D-065ABK esopruPlareneG 135ABK "526. "0.8-"060. F052< 409-650-380

    .J 103AD esopruPlareneG 335ABK "574. "0.8-"050. F041< 509-650-380

    .K 303AD noitarteneP 335ABK "536. .nim"002. F041< 401-165-311

    .L 401-PD noitartenePhgiH 235ABK "52.1 .nim"002. F031< 600-255-311

    .M RW-E2HF tnatsiseRraeW dettoP "055. "0.2-"030. F031< 212-445-311

    .N RW-065ABK tnatsiseRraeW 135ABK "007. "0.8-"060. F054< 500-255-311

    .O **RW-D-E2HF tnatsiseRraeW dettoP "055. "0.2-"030. F031< 800-255-311

    .P 004TH A004TH erutarepmeThgiH535ABK635ABK "005. "0.01-"040. F0001