PHASE Lifetime
FAMILY 1 3 5 Buy? REPLACEMENT
1800 transmitter 1994 2001 2003 Yes - 2-3.5 yrs 3300 XL, 3500, 1701, 1900
300 and 190 series probes 60'S 2000 2002 No 3300 XL or 3300 NSV™ probes
3000-series transducers 60'S 2000 2001 Yes - 1 year 3300 XL or 3300 RAM Proximitor® Sensors
3300 5 & 8 mm Proximitor® Sensor 1990 2001 2003 Yes - 2.29 yrs 3300 XL Proximitor® Sensor
3300 probe/extension cable 1990 1998 1998 No 3300 XL probes/extension cable
6P SS Proximitor® Sensor housing 1982 2000 2003 No 3300 XL Housing
70000-series radiation resistant 1982 2002 2004 Yes - < 8 years New Radiation Resistant Transducer
7000-series transducers - 5 metre 70'S 2000 2001 Yes - 1 year 3300 XL or 3300 RAM Transducer Systems
7000-series transducers - 9 metre 70'S 1999 1999 Yes - 1 year 3300 XL or 3300 RAM Transducer Systems
7200 (standard range) 1977 2001 2003 Yes - < 8 years 3300 XL
7200 11 mm 1977 2000 2001 Yes - < 8 years 3300 XL 11 mm
7200 high pressure feedthrough 1982 2001 2003 No 3300 HP FDTH
7200-series 14 mm 1988 2001 2001 Yes - < 8 years 3300 XL 11 mm
7200-series 25 mm 1982 1996 2002 Yes - 2 years 25 mm DE/7200 35 mm
7200-series 35 mm 1988 2002 2003 Yes - < 8 years 25 mm DE
7200-series 50 mm 1982 1999 Yes - < 8 years 50 mm DE
7200-series REBAM® 1984 2002 2003 No 3300 REBAM®
25 mm Differential Expansion Transducer 1993 2002 2003 Yes - 2 years 3300 XL 25 mm Transducer?
RAM probe/extension cable 1994 1999 1999 No 3300 NSV™
RAM Proximitor® Sensor 1994 2003 2004 Yes - 2.29 yrs 3300 NSV™
Standard temperature DC LVDTs 1984 2002 2010 No ETR LVDT's
Trendmaster® 7200-series REBAM® TIM 1994 2002 2003 No 3300 REBAM® TIM (under
development)
Valve position potentiometer 1986 2002 No Rotary Psn Xdcr
PHASE #1: Product is released to market; actively sustained and enhanced
PHASE #2: Product sustaining / support activity continues, but no enhancement (additional functionality) planned
PHASE #3: Product is not available for new installations; spares only
PHASE #4: Repair only
PHASE #5: OBSOLETE Product is no longer supported by Bently Nevada, and is not recommedned for use