24
1 Trade Effluent Miscellaneous Guidance Version: 1.0 Date: 24 April 2020 Owner: Trade Effluent Issues Committee (TEIC)

Trade Effluent Miscellaneous Guidance

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

1

Trade Effluent Miscellaneous

Guidance

Version: 1.0

Date: 24 April 2020

Owner: Trade Effluent Issues Committee (TEIC)

2

About this Document This document sets out best practices and workarounds for issues relating to trade effluent issues.

This document will only apply to the items set out within its Table of Content. For the avoidance of

doubt, this document is intended to provide guidance on trade effluent issues and not to be taken as

a market code document.

Out of Scope This document seeks to ensure its readers are kept updated on issues and deliver workarounds to

known Trade Effluent issues. This document shall ensure that all guidance information is aligned

with market codes. All discussed scenarios within this document should be noted within its entirety,

purpose and not deemed as real-life practicalities.

Version History Version Update Date

Version 1.0 Initial Version Creation 24 April 2020

Authorisation and Approval Name Title Date of Issue Version

TEIC Panel sub committee 22 April 2020 Version 1.0

Distribution This document has been distributed to the following people:

Name Title Purpose Date Version

TEIC Panel sub committee Review Version 1.0

Attached Documents There are documents embedded to this specification.

3

Table of Contents Definitions and Acronyms ....................................................................................................................... 4

Setting the Scene .................................................................................................................................... 5

List of Trade Effluent Related Transactions ............................................................................................ 6

1. Calculated Discharges ..................................................................................................................... 7

1.1 Creation of Calculated Discharges .............................................................................................. 7

1.2 Calculated Discharges – Retailer ............................................................................................... 10

1.3 Amending Calculated Discharge Volumes ................................................................................ 11

1.4 Functionality to allow erasure of Calculated Discharge Notified Volume ................................ 13

1.5 Amending the Yearly Volume Estimates (YVEs) of Calculated Discharges ............................... 15

1.6 Removal of Calculated Discharges ............................................................................................ 18

2. Guidance for Trade Effluent Strength Determination / Methodology ......................................... 18

3. Trade Effluent Transactions with Free Field Descriptors .............................................................. 22

4. Best Practice around TE Free Field Descriptors ............................................................................ 24

4

Definitions and Acronyms Terms Acronyms

CMOS Central Market Operating Systems

CD Calculated Discharges

YVE Yearly Volume Estimates

MDVOL Meter Daily Volume

FA Fixed Allowance

PA Percentage Allowance

SVAM Sewerage Volume Adjustment Method

CSD Code Subsidiary Document

WRC Wholesale Retail Code

MVI Medium Volume Interface

HVI High Volume Interface

For all Trade Effluent-related terminologies and definitions, please click here to access the Jargon

Buster. The Jargon Buster provides a breakdown of complex Trade Effluent terminologies for easy

comprehension.

5

Setting the Scene As stipulated within the Market Codes, the Central Systems (CMOS) permits trading parties to share

and maintain data pertaining to supply points. CMOS ensures that customer data is stored and used

for the purpose of reporting and Settlement.

In setting the scene for Trade Effluent related activities, it is worth noting that information relating

to these processes can be found in the following Market Codes:

• Code Subsidiary Document (CSD) 0206 Trade Effluent Processes;

• CSD 0207 Charge Calculation, Aggregation and Allocation;

• CSD 0301 Data Catalogue; and

• WRC Schedule 1 Part 3 Operational Terms.

Trade Effluent activities in CMOS are initiated with the existence of a Sewerage Service for a

Premise. The figure below illustrates the design intent of structures within CMOS.

Figure 1: CMOS Data Structure

NOTE: A successful T168.W transaction requires a Sewerage Service and a Trade Effluent Service

Component (SC). Unlike other Sewerage SCs which can be added via the T140.W (Submit

Sewerage SC) transaction, a Trade Effluent Service Component is created by submitting the

T121.W (Submit new DPID Request) transaction.

Water SPID Sewerage SPID

Customer (e.g. MOSL)

Premises (e.g. 100 MOSL Way)

Supply Points

Service Component Service Component

Tariff Tariff Tariff Data

Meters

DPID

TE Tariff Data

6

List of Trade Effluent Related Transactions The list below states all transactions in the Central Systems (CMOS) that pertain to Trade Effluent

Services (activities). It is worth noting that the list below excludes the relevant .M transactions.

Transaction Number

Transaction Name Description

T104.W Install Meter Creation of Private Water or Private Trade Effluent Meter. Other meter transactions as per Supply meters.

T121.W Submit DPID Submission of a new Discharge Point by Sewerage Wholesaler

T122.W Update Trade Effluent Operating Data

Update of Discharge Point operating data

T123.W Submit Discharge Point Meter Association

Submission by Wholesaler identifying meter associated with a Discharge Point, and the relevant percentage through the meter to be applied to the Discharge Point. The SPID specified must be the Sewerage SPID.

T124.W Submit Discharge Point Meter Disassociation

Submission by Wholesaler of a meter disassociated with a Discharge Point

T125.R Submit Calculated Discharge Volumes

Submission of Trade Effluent calculated volume for Settlement calculations. Each notification should be for the volume measured since the previous submission

T126.W Update Trade Effluent Tariff or Terminate DPID

Submission by Wholesaler of change to Trade Effluent tariff or termination of a Discharge Point

T127.W Update DPID Details Update to a Discharge Point by Wholesaler

T128.W Submit Trade Effluent Special Agreement

Initial submission and ad hoc updates of Special Agreement in effect at a Discharge Point

T136.W Submit Meter Network Data Submission of a Network for a Supply Meter to a Private Water or Private Trade Effluent Meter

T150.W Submit Trade Effluent Volumetric Adjustment

Submission of Trade Effluent Volumetric Adjustment updates from the Wholesaler

T168.W Submit Calculated Discharge Details

Sets up Calculated Discharges at a Discharge Point

T169.W Discontinue Calculated Discharge Details

Allows a Wholesaler to discontinue Calculated Discharges

TCORR178.W Amend DPID Effective Dates

Submission by Wholesaler of a change of DPID Effective From Date. This is a Retrospective Amendment Data Transaction only

TCORR179.W Erase DPID Submission by Wholesaler to Erase a DPID. This is a Retrospective Amendment Data Transaction only

7

1. Calculated Discharges

1.1 Creation of Calculated Discharges A Calculated Discharge is a mechanism in CMOS that allows for the submission of volume that

cannot be derived by deducting allowances from metered water supplied.

1) How Calculated Discharges are used in account set-ups

• SVAM of NONE Any Calculated Discharges that is created will be used in the TE volume calculation. The Calculated

Discharges volume is added after any metered/allowance volume is calculated.

The Calculated Discharges will not impact on the sewerage calculation.

• SVAM of DA Any Calculated Discharges that is created will be used in the TE volume calculation. The Calculated

Discharge volume is added after any metered/allowance volume is calculated.

The DPID’s Domestic Allowance will impact on the sewerage calculation.

• SVAM of SUBSTRACT Any Calculated Discharges that is created will be used in the TE calculation. The Calculated

Discharges volume is added to any Private TE Meter volume.

Sewerage volume is impacted: the total Calculated Discharges volume on the DPID will be subtracted

from the total volume of foul sewerage.

2) Setting up calculated discharges These are set up at Discharge Points (DPIDs) by wholesalers via T168.W (Submit Calculated

Discharge Details). The table below sets out the data items involved within the transaction.

Table 1: T168.W Submit Calculated Discharge Details

Transaction Number T168.W

Transaction Name Submit Calculated Discharge Details

From Wholesaler

To Market Operator

Data Item Number Name Notes

D2001 SPID Required

D6001 DPID Required

D6023 Calculated Discharge ID Required

D6022 Discharge Type Required

D4022 Effective From Date Required

D6025 Submission Frequency Required

D2010 Yearly Volume Estimate Required

D4003 Text Comment Field Optional

Calculated Discharge ID (D6023) can be a unique reference for the discharge. This is a free text field

for wholesalers to provide unique identification references for the discharge.

8

Discharge Type (D6022) refers to the type of effluent emitted from the NHH Customer site. The

types of discharge are;

➢ Contaminated A volume of Trade Effluent that results from contaminated surface water

➢ Estimated A volume of Trade Effluent that is difficult to measure and as such has been estimated by the Wholesaler using data provided by the customer

➢ Generic A volume of Trade Effluent that has to be calculated outside of CMOS due to the complexity of DPID set up

➢ Delayed A volume of Trade Effluent that has been determined following a delay in volumetric measurement capability

➢ Tankered A Trade Effluent volume that results from a liquid volume tankered into the site.

Submission Frequency (D6025) for Calculated Discharge indicate the regularity at which volumes

could be submitted. The frequencies for submission are;

➢ Bi-annually (B); ➢ Monthly (M); or ➢ Never (N).

Only frequencies of B and M require retailer-submitted volume.

Monthly (M)/ Bi-Annually (B)

These frequencies indicate that the created CD will need to have its volumes updated on a regular

basis. The Retailer would need to submit volumes through T125.R or TCORR125. R. The Wholesaler

provides a YVE so, if a CD has an insufficient history of volume, the YVE can be utilised in CD volume

estimation.

Never (N)

This frequency means that the created Calculated Discharge will not require volumes submitted

against it. Instead, the YVE will be used directly in settlement calculations. A daily estimated volume

will be derived from the YVE and this will be applied at the CD between the effective dates on the

T168.W. The image below shows a successful set up of a Calculated Discharge.

It is worth noting that where a new discharge is submitted, a change in the frequency may require

retailer input.

9

Figure 2: Calculated Discharge Set Up

The Effective From Date must always be within two 2 months of the current date. TCORR168 Submit

CD Data can be used to set an alternative Effective From Date.

3) When Calculated Discharges may be used

• When a site is too complex to enable the trade effluent volume to be calculated in CMOS (this

may or may not include supply or private meters). The Calculated volume may be calculated

by the Retailer or Wholesaler depending on the Submission Frequency of the Calculated

Discharge.

• The volume of Trade Effluent cannot practically be measured and so an agreed estimated

volume is used.

• The volume of Trade Effluent is very small compared to the site usage that an agreed

estimated volume is used.

• The volume of Trade Effluent is calculated from standard rainfall / surface areas.

• The volume of Trade Effluent is provided by the Customer (it may not be measureable through

metering or the measurement device is not continuous, or it is a volume in addition to the

metered volume).

• As a work around for a trade effluent volume that originates from a different SPID (i.e. the

premises is split between 2 SPIDs).

• As an alternative to a Trade Effluent Adjustment for a period of time when the Trade Effluent

volume requires alteration due to a site or measurement incident.

Discharge ID

Discharge Type Submission

Frequency

YVE

10

1.2 Calculated Discharges – Retailer This can then sometimes be followed by retailer-submitted volume with T125.R (Submit Calculated

Discharge Volume). The table below sets out the required data items for this transaction.

Table 2: T125.R Submit Calculated Discharge Volumes

Transaction Number T125.R

Transaction Name Submit Calculated Discharge Volumes

From Retailer

To Market Operator

Data Item Number Name Notes

D2001 SPID Required

D6001 DPID Required

D6008 Calculated Discharge Notified Volume Required

D4006 Effective From Date Required

D4024 Effective To Date Required

D6023 Calculated Discharge ID Required

D4003 Text Comment Field Optional

Calculated Discharge Notified Volume (D6008) indicates the volume discharged for the Calculated

Discharge. It is worth mentioning that all volumes in CMOS is notified in m3.

Figure 3: Notified Calculated Discharge Volumes

11

1.3 Amending Calculated Discharge Volumes Calculated Discharges Volumes are modelled in a similar way to meters.

Problem Definition:

Where a retailer has acquired a sewerage SPID which has a DPID and calculated discharges, volumes

may not have been submitted by the previous retailer up until the switching date. There is a defect

(S642) where the outgoing retailer cannot submit discharge volumes through T125.R, for a period

before the SPID Registration Start Date (RSD), after the SPID RSD. The workaround for this issue is to

submit the volume via TCORR125. R.

Where a retailer has submitted an incorrect discharge volume, this cannot be amended thereafter

through TCORR125.R

Figure 4: Calculated Discharge timeline

General Principles on Calculated Discharges:

It is worth noting that if you set the Calculated Discharge with a volume submission to

Never, you will not be able to submit volumes under the respective Calculated Discharge.

Calculated Discharge does not permit the existence of gaps within volume submission.

Calculated Discharge will use the YVE in the absence of volumes.

Settlement for a meter with readings uses the meter reading history. It doesn’t return to

simply using the YVE (or ILE where a YVE does not exist).

A Calculated Discharge with volumes cannot be changed into a Calculated Discharge without

volume submission.

Calculated

discharge’s EFD

01/01/2018

Discharge

volume

Discharge

volume

31/03 01/04 19/08/2018

Currently, TCORR125.R cannot

be used to overwrite either of

these two previously

submitted volumes

12

Workaround and Solution

A functionality deployed in Release 6.5 (26 July 2019) amended the defect to allow amendments of

Calculated Discharge volume via the TCORR125.R transaction. The functionality will ensure that

retailers will be able to amend the Calculated Discharge Volume, but the Effective dates will need to

be left unchanged.

Table 3: TCORR125.R Submit Calculated Discharge Volume Amendment

The highlighted image section within Figure 3 shows the submission of calculated discharge volume

for a discharge point. In order to amend the volume of the discharge, the retailer must issue a

TCORR125. R. The image below shows the amendment via the TCORR125.R transaction.

Figure 5: Successful submission of a TCORR125.R

Transaction Number TCORR125.R

Transaction Name Submit Calculated Discharge Volumes

From Retailer

To Market Operator

Data Item Number Name Notes

D2001 SPID Required

D6001 DPID Required

D6023 Calculated Discharge ID Required

D6008 Calculated Discharge Notified Volume Required

D4006 Effective From Date Required

D4024 Effective To Date Required

D4031 Authorisation Code Required

D4003 Text Comment Field Optional

13

1.4 Functionality to allow erasure of Calculated Discharge Notified Volume In the event where a retailer enters the incorrect volume for a calculated discharge, there is no

process or functionality to amend or remove the errored information. As an initial starting point,

retailers can utilise the TCORR125.R to amend the volume.

The principles for Calculated Discharges do not allow any gaps between the dates of the submission

and thus, requires the dates to remain unchanged. The image below shows a submission of volumes

for a Calculated Discharge. The item highlighted in red is subject to change.

Figure 6: errored Calculated Discharge

Retailers can submit TCORR125.R to amend the volume (i.e. change to 0) to remove the discharge

volume. The image below shows the transaction in LVI (Low Volume Interface) portal, which would

be issued by the retailer.

The item highlighted in RED shows an

Amendment to the Calculated Discharge

Notified Volume (D6008).

The items highlighted in BLUE shows the

Effective From Date (D4006) and the

Effective To Date (D4024) unchanged from

Figure 6.

Figure 7: Amending Calculated Discharge Volume

14

Upon the successful issuance of the TCORR125.R transaction to amend the volume, Figure 8

illustrates the amendment to the Calculated Discharge volume.

Figure 8: Amendment of Calculated Discharge Volume

15

1.5 Amending the Yearly Volume Estimates (YVEs) of Calculated Discharges Similar to the extrapolation of metered volume situations, in the absence of Calculated Discharge

volume, the Yearly Volume Estimate (YVE) is used to estimate volumes and charges. Where the

existing volumes are fewer than 30 days, a blend of the YVE and volume history is used. The YVE is

set via the T168.W Submit Calculated Discharge Data transaction.

If the existing volumes of Calculated Discharge are greater than 30days, the volume history is used

to extrapolate volumes. For example;

Calculated Discharge → Volume of 1825 m3 submitted for 2017-18 → Estimation shall be computed

as→ 1825/365 → CMOS will estimate 5 m3 for the daily Calculated Discharge.

Upon the creation of the Calculated Discharge, the YVE must be specified as there is no transaction

that allows Calculated Discharge to treat YVEs in a similar manner to how meters allocate YVEs for

certain periods. When a YVE is set, it shall remain the same for the entirety of its history and thus

when a new YVE is set for the same Calculated Discharge, it shall be set for the entire period of the

Calculated Discharge, including retrospectively

For example: the YVE of 1000 is set from 1 April 2017 → the YVE is changed to 2000 from 10

December 2018 → the old YVE record is retired and the new YVE shall take effect from the 1 April

2017.

The image below illustrates the YVE data in CMOS LVI portal.

Figure 9: YVE Data in CMOS LVI

To amend the YVE of the Calculated Discharge, the wholesaler must submit a TCORR168.W Submit

Calculated Discharge Data Amendment transaction. The table shows the data items requirement for

the TCORR168.W transaction.

YVE Data

16

Table 4: TCORR168.W Submit Calculated Discharge Details Amendment

Transaction Number TCORR168.W

Transaction Name Submit Calculated Discharge Details Amendments

From Wholesaler

To Market Operator

Data Item Number Name Notes

D2001 SPID Required

D6001 DPID Required

D6023 Calculated Discharge ID Required

D6022 Discharge Type Required

D4006 Effective From Date Required

D4022 Effective To Date Required on Change (Optional)

D6025 Submission Frequency Required

D2010 Yearly Volume Estimate Required

D4031 Authorisation Code Required

D4003 Text Comment Field Optional

Upon a successful submission of the TCORR168.W, CMOS will amend the YVE for the history of the

Calculated Discharge. The image below shows the amendment to the YVE Data.

Figure 10: Amended YVE

New YVE

17

Problem Definition: currently, there is no functionality to allow multiple periods within a Calculated

Discharge to have different YVEs. The workaround requires both trading parties to agree on a

prescribed YVE value for a specified period. Subject to both trading parties agreeing on a YVE value,

the wholesaler shall create a new Calculated Discharge with a different Calculated Discharge ID with

a new YVE. The process shall be repeated for the entirety of the periods.

Figure 11: Submission of T168.W for new Calculated Discharge Details

It is also worth nothing that within the T168.W process, the wholesaler shall set the Submission

Frequency (D6025) to Never (N). This will remove any retailer involvement in the submission process

as no volume can be submitted when the frequency is set to Never (N).

Figure 12: Calculated Discharges with no volumes

18

1.6 Removal of Calculated Discharges Currently, there is no functionality to delete/remove a Calculated Discharge once it is created using

T168.W or TCORR168.W.

As such, should a Calculated Discharge be created in error then it is recommended that a

TCORR168.W transaction is used to amend the YVE to zero, and the Effective From and To dates

amended such that that they sequential (e.g. 1/4/17 and 2/4/17) so that Calculated Discharges not

in use can more easily be identified. Please note that Effective From and To dates cannot be the

same date).

2. Guidance for Trade Effluent Strength Determination /

Methodology Wastewater companies have different ways of determining the charging strength for trade effluent.

These differ from company to company as well as within a company for different categories of

discharge.

To get the strength determination for a specific discharge the best option is to consult the

Wholesaler’s NHH Charges Scheme documentation. Alternatively, a G01 can be raised.

The general principles of TE Strength determination are as follows:

Zero is a valid entry [NO MOGDEN CHARGE]

If a DPID is set up such that it does not incur a volumetric charge relating to the MOGDEN

calculation, then the Ot, St and At (or any other charging determinants) will be zero.

An example of this type of DPID, is one that only incurs a standing charge because it is a Low Risk

Consent.

In some cases, a DPID may only have the R and/ or V components attributed to account, which do

not require values for Ot, St and At (or any other charging determinants).

An example of this type of account, is where a discharge is made to surface water sewer and as such

the discharge only receives service of the ‘Reception and Conveyance’ and no treatment at a sewage

treatment works.

Standard Strength or Regional Strength [STANDARD STRENGTH]

These will be published in a Wholesaler’s NHH Charges Scheme and will include a type of discharge

together with associated strength of Ot, St and At (or any other charging determinands) that it will

apply for such a discharge.

Generally, this type of trade effluent strength is used for lower risk discharges, often of similar types

across many Wholesalers, such as vehicle washing and launderettes.

A Wholesaler may allow a discharge of this type to use alternative trade effluent strengths for

charging, however, this is likely to only be accepted with supportive evidence.

Agreed Strength or Continuous Strength or Fixed Strength or Banded Strength [CONTINUOUS

FIXED STRENGTH]

Generally, this type of trade effluent strength is used for lower risk discharges.

19

However, they may also be used in the following scenarios:

• Batch discharges

• Hard to take representative samples of discharge

• Highly variable discharges

• Small/low risk discharges

Agreed Strengths have been determined by a sampling study or other available information. If a

Retailer believes that an Agreed Strength is not suitable or no longer representative of a discharge,

they should contact the Wholesaler to discuss the process or options for determining/using a

different strength.

Actual samples

There are a number of ways samples results taken throughout the year may be applied to determine

the trade effluent strength.

Whether or not a specific sample analysis is included in the determination is dependent on the

Wholesaler, for example, some may apply a statistical analysis to remove very high or low strength

results, whilst others will include all results if the sample taken was representative of what was being

discharged at the time.

a. Annual Fixed Strength [1YR FIXED STRENGTH]

Samples are taken throughout a year then used to determine a representative charging strength for

the following year. i.e. the previous year’s trade effluent strength will be apply to the current year’s

volume.

It is likely that the sample results will undergo a form of statistical analysis to determine the charging

strength.

As such the Ot, St and At (or any other charging determinants) are the same throughout a year

(generally the FY).

b. 3 yearly Fixed Strength [3YR FIXED STRENGTH]

Samples are taken throughout a 3-year period then used to determine a representative charging

strength for the following 3 years.

It is likely that the sample results will undergo a form of statistical analysis to determine the charging

strength.

As such the Ot, St and At (or any other charging determinants) are the same throughout a 3-year

period.

c. Seasonal Fixed Strength [SEASONAL STRENGTH]

Historical samples are used to determine a representative charging strength for a set period of time

during a year. The Wholesaler would need to be contacted for specific details regarding the seasonal

time periods.

As such the Ot, St and At will vary during the year for specific periods. It is likely that the sample

results will undergo a form of statistical analysis to determine the charging strength.

20

d. Settlement Period Average [SETTLEMENT PERIOD STRENGTH]

Samples taken are used for the settlement periods in which they are taken.

If there is more than one sample taken during the period, then it is likely that an average of the two

will be taken to determine the charging strength.

The Ot, St and At (or any other charging determinants) will vary during a year. Variation month to

month may be significant.

e. Rolling Period Average [12 MONTH ROLLING AVERAGE], [6 MONTH ROLLING AVERAGE] or [3

MONTH ROLLING AVERAGE]

Samples taken through the year apply to specific rolling period averages, for example, 3, 6 or 12

months.

This means that for a 3-month rolling period, a sample taken in May will not only be included in the

May settlement period, but also June and July as well. In other words, a July charge period will

consider all samples taken in July, June and May. An August charge period will consider all samples in

August, July and June, and so on.

The average of relevant results for a settlement period will be used as the trade effluent strength.

The Ot, St and At (or any other charging determinants) will vary during a year. Variation month to

month is limited due to averaging of samples across a number of months.

f. Rolling Sample Number Average [SAMPLE NUMBER ROLLING AVERAGE]

The Ot, St and At are updated whenever a new sample is taken. When a new sample is taken, the

charging strength is calculated using the most recent X number of samples; X being specified in the

Wholesaler Charge Scheme. Therefore, if a sample is taken in the middle of a settlement period,

then new Ot, St and At will be used for the days of the sample date and onwards until another

sample is taken.

The Ot, St and At (or any other charging determinants) will vary during a year and during a month /

charge period.

g. Most Recent Actual Sample [MOST RECENT ACTUAL SAMPLE]

The Ot, St and At for a specific charge period are the most recent sample analysis. i.e. every time a

sample is taken, and the results are available, the Ot, At and St in the market are updated with the

results at that time and will remain until the next sample is taken. Therefore, if a sample is taken in

the middle of a settlement period, then the original Ot, St and At will be used for the days prior to

the new sample date and the new Ot, St and At will be used for the days of the sample date and

onwards.

The frequency of this can be varied so the Ot, St and At (or any other charging determinands) will

vary during a year and possibly during a month.

21

Averaging of Samples

For most scenarios where actual samples are taken, an average of the sample results is used. There

are a number of different ways an average may be calculated;

Straight average of results in mg/l

This means that the sample results are all added together and then divided by the number of results

to get the average value.

Volumetrically adjusted or Weighted average

This means that each sample result is converted into a load by using the associated volume

discharged during the period of the sample. All loads are then added together and divided by the

total volume to determine the charging strength.

The reason for doing this is to take into account a changing discharge profile e.g. low discharge

volumes at a high strength one month, and large discharge volumes of low strength another month.

Statistical analysis combined with either (i) or (ii).

Charging Strength CMOS Option Summary

• NO MOGDEN CHARGE

• STANDARD STRENGTH

• CONTINUOUS FIXED STRENGTH

• 1YR FIXED STRENGTH

• 3YR FIXED STRENGTH

• SEASONAL STRENGTH

• SETTLEMENT PERIOD STRENGTH

• 12 MONTH ROLLING AVERAGE

• 6 MONTH ROLLING AVERAGE

• 3 MONTH ROLLING AVERAGE

• SAMPLE NUMBER ROLLING AVERAGE

• MOST RECENT ACTUAL SAMPLE

• OTHER

NOTE: The above will also apply to other charging parameters Xt, Yt and Zt if these are enabled.

22

3. Trade Effluent Transactions with Free Field Descriptors Data submitted into the Central Systems has been parameterised to allow specific combinations into

the system. Whilst some data are included as a valid set, other data require manual input i.e. a free

field descriptor field.

Data items with free descriptor fields can tend to impact on the calculation of settlement/charges

(such as meter reads, calculated discharge volumes etc.) as long that data logical type is met.

However, some data items may not impact or have minimal impact on operational processes to

trading parties such as Text Comment Field, Secondary Addressable Object etc. The purpose of this

section of the guidance document is to provide best practice information on how to utilise free field

descriptors for Trade Effluent related transactions. The table below shows a list of Trade Effluent

transactions with free field descriptors.

Table 5: Trade Effluent Transactions

Transaction Number

Transaction Name Description Text Comment Field

Visible on LVI

T121.W Submit DPID Submission of a new

Discharge Point by Sewerage Wholesaler

Y N

T122.W Update Trade Effluent Operating Data

Update of Discharge Point operating data

Y N

T123.W

Submit Discharge Point Meter Association

Submission by Wholesaler identifying meter associated with a Discharge Point, and the relevant percentage through the meter to be applied to the Discharge Point. The SPID specified must be the Sewerage SPID.

Y N

T124.W Submit Discharge Point Meter Disassociation

Submission by Wholesaler of a meter disassociated with a Discharge Point

Y N

T125.R

Submit Calculated Discharge Volumes

Submission of Trade Effluent calculated volume for Settlement calculations. Each notification should be for the volume measured since the previous submission

Y N

T126.W

Update Trade Effluent Tariff or Terminate DPID

Submission by Wholesaler of change to Trade Effluent tariff or termination of a Discharge Point

Y N

T127.W Update DPID Details Update to a Discharge

Point by Wholesaler Y N

T128.W Submit Trade Effluent Special Agreement

Initial submission and ad hoc updates of Special

Y N

23

Transaction Number

Transaction Name Description Text Comment Field

Visible on LVI

Agreement in effect at a Discharge Point

T150.W

Submit Trade Effluent Volumetric Adjustment

Submission of Trade Effluent Volumetric Adjustment updates from the Wholesaler

Y N

T168.W Submit Calculated Discharge Details

Sets up Calculated Discharges at a Discharge Point

Y N

T169.W Discontinue Calculated Discharge Details

Allows a Wholesaler to discontinue Calculated Discharges

Y N

TCORR178.W

Amend DPID Effective Dates

Submission by Wholesaler of a change of DPID Effective From Date. This is a Retrospective Amendment Data Transaction only

Y N

TCORR179.W

Erase DPID

Submission by Wholesaler to Erase a DPID. This is a Retrospective Amendment Data Transaction only

Y N/A

24

4. Best Practice around TE Free Field Descriptors This section of the guidance provides best practice information on the utilisation of the TE

transactions with free field descriptors.

Transaction ✅ Best Practise for D4003 Text Comment Field

1) T121.W Submit DPID

Confirmation of discharge type - Consent, STDA. SVL (Short terms) and any further information deemed appropriate

2) T122.W Update Trade Effluent Operating Data

If to be utilised identifier for Fixed Forward, Agreed strengths, variable strengths - ammonia enhancement

3) T123.W Submit Discharge Point Meter Association

Potential to use for confirmation of installation/exchange reason etc

4) T124.W Submit Discharge Point Meter Disassociation

Potential to use for confirmation of removal reason etc

5) T125.R Submit Calculated Discharge Volumes

Explanation from Retailer of how volume was calculated and when it would be reviewed

6) T126.W Update Trade Effluent Tariff or Terminate DPID

Potential to use for confirmation of amendment &/or removal reason etc

7) T127.W Update DPID Details

Confirmation of data updates - what aspect had been updated when completing transaction

8) T128.W Submit Trade Effluent Special Agreement

9) T150.W Submit Trade Effluent Volumetric Adjustment

Break down of allowance and calculation provided

10) T168.W Submit Calculated Discharge Details

Used at current - provides details around calculation to arrive at figure

11) T169.W Discontinue Calculated Discharge Details

Potential to use for confirmation of removal reason etc

12) TCORR178.W Amend DPID Effective Dates

Potential to use for confirmation of amendment reasons

13) TCORR179.W Erase DPID Potential to use for confirmation of removal/erasing reasons

Things to Note:

• D4003 only allows 255 characters; and

• This field may not be available for HVI or MVI interfaces.