12
TPR 280, 80 °C, DN 16 ISO-KF Flange size: DN 16 ISO-KF For general vacuum applications Compact and rugged Maximum pressure refers to inert gases Similar Image Dimensions Technical Data TPR 280, 80 °C, DN 16 ISO-KF Accuracy: 1 · 10 -3 – 100 hPa ± 15 % Bakeout temperature 80 °C Feature Stainless steel, metal sealed Feedthrough Glass Filament Tungsten Flange Edelstahl Measurement range max. 1 · 10 3 hPa | 7.5 · 10 2 Torr | 1 · 10 3 mbar Measurement range min. 5 · 10 -4 hPa | 3.75 · 10 -4 Torr | 5 · 10 -4 mbar Method of measurement Pirani Nominal diameter DN 16 ISO-KF Output signal: Measurement range 2.2 - 8.5 V Output signal: Minimum load 10 kΩ Protection category IP40 www.pfeiffer-vacuum.com Page 2

TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

  • Upload
    ngotu

  • View
    227

  • Download
    2

Embed Size (px)

Citation preview

Page 1: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

TPR 280, 80 °C, DN 16 ISO-KF

Flange size: DN 16 ISO-KF

For general vacuum applications

Compact and rugged

Maximum pressure refers to inert gases

Similar Image

Dimensions

Technical Data TPR 280, 80 °C, DN 16 ISO-KF

Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar

Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar

Method of measurement PiraniNominal diameter DN 16 ISO-KFOutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40

www.pfeiffer-vacuum.com Page 2

Page 2: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

Technical Data TPR 280, 80 °C, DN 16 ISO-KF

Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. ≤ 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 1.5 cm³Weight 80 g

Order number

TPR 280 PT R26 950

Accessories

AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -TVacuum accessoriesCentering ring with metal mesh-fine filter,pore size 4 m, FPM/stainless steel PT 120 132 -TCentering ring with protection filter,pore size 20 m, FPM/stainless steel PF 117 216 -T

www.pfeiffer-vacuum.com Page 3

Page 3: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

TPR 280, 80 °C, DN 16 CF-R

Flange size: DN 16 CF-R

For general vacuum applications

Compact and rugged

Maximum pressure refers to inert gases

Similar Image

Dimensions

Technical Data TPR 280, 80 °C, DN 16 CF-R

Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar

Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar

Method of measurement PiraniNominal diameter DN 16 CF-ROutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40

www.pfeiffer-vacuum.com Page 2

Page 4: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

Technical Data TPR 280, 80 °C, DN 16 CF-R

Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 1.5 cm³Weight 100 g

Order number

TPR 280 PT R26 951

Accessories

AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T

www.pfeiffer-vacuum.com Page 3

Page 5: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

TPR 280, 80 °C, 8 VCR

Flange size: DN 8 VCR

Maximum pressure refers to inert gases

Compact and rugged

For general vacuum applications

Similar Image

Dimensions

Technical Data TPR 280, 80 °C, 8 VCR

Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature Stainless steel, metal sealed

www.pfeiffer-vacuum.com Page 2

Page 6: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

Technical Data TPR 280, 80 °C, 8 VCR

Feedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar

Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar

Method of measurement PiraniNominal diameter 8 VCROutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 2 cm³Weight 130 g

Order number

TPR 280 PT R26 953

Accessories

AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T

www.pfeiffer-vacuum.com Page 3

Page 7: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

TPR 280, 80 °C, 1/8" NPT

Maximum pressure refers to inert gases

Compact and rugged

Fast, stable measurement

Similar Image

Dimensions

Technical Data TPR 280, 80 °C, 1/8" NPT

Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 80 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar

Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar

Method of measurement PiraniNominal diameter 1/8" NPT

www.pfeiffer-vacuum.com Page 2

Page 8: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

Technical Data TPR 280, 80 °C, 1/8" NPT

Output signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 2 cm³Weight 70 g

Order number

TPR 280 PT R26 952

Accessories

AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T

www.pfeiffer-vacuum.com Page 3

Page 9: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

TPR 280, 250 °C, DN 16 ISO-KF

Flange size: DN 16 ISO-KF

Maximum pressure refers to inert gases

Compact and rugged

For general vacuum applications

Similar Image

Dimensions

www.pfeiffer-vacuum.com Page 2

Page 10: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

Technical Data TPR 280, 250 °C, DN 16 ISO-KF

Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 250 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar

Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar

Method of measurement PiraniNominal diameter DN 16 ISO-KFOutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 10 cm³Weight 130 g

Order number

TPR 280 PT R26 960

Accessories

AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -TTPR 280 PiraniTPR 280, 80 °C, DN 16 ISO-KF PT R26 950Vacuum accessoriesCentering ring with metal mesh-fine filter,pore size 4 m, FPM/stainless steel PT 120 132 -TCentering ring with protection filter,pore size 20 m, FPM/stainless steel PF 117 216 -T

www.pfeiffer-vacuum.com Page 3

Page 11: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

TPR 280, 250 °C, DN 16 CF-R

Flange size: DN 16 CF-R

Maximum pressure refers to inert gases

Compact and rugged

For general vacuum applications

Similar Image

Dimensions

www.pfeiffer-vacuum.com Page 2

Page 12: TPR€280, 80€°C, DN€16€ISO-KF - hakuto-vacuum.jp · TPR 280 Pirani TPR€280, 80€°C, DN€16€ISO-KF PT R26 950 Vacuum accessories Centering€ring€with€metal€mesh-fine€filter,

Technical Data TPR 280, 250 °C, DN 16 CF-R

Accuracy: 1 · 10-3 – 100 hPa ± 15 %Bakeout temperature 250 °CFeature Stainless steel, metal sealedFeedthrough GlassFilament TungstenFlange EdelstahlMeasurement range max. 1 · 103 hPa | 7.5 · 102 Torr | 1 · 103 mbar

Measurement range min. 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar

Method of measurement PiraniNominal diameter DN 16 CF-ROutput signal: Measurement range 2.2 - 8.5 VOutput signal: Minimum load 10 kΩProtection category IP40Repeatability: 1 · 10-3 – 100 hPa ± 2 %Resolution 1 % of readingResponse time 80 msSeal MetalSupply: Power consumption max. 1 WSupply: Voltage 14-30 V DCTemperature: Operating 5 – 60 °CTemperature: Storage -20 – 65 °CVolume 10 cm³Weight 140 g

Order number

TPR 280 PT R26 961

Accessories

AccessoryMating connector B 4707 283 MAMeasurement cableSensor cable, 3 m PT 448 250 -T

www.pfeiffer-vacuum.com Page 3