92
TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement Solutions for Test Measurement and Metrology Customers. Call 623-434-5110 For Orders or Information. Or visit http://www.toveyengineering.com Precision, Fatigue Rated, and Metrology Grade Load Cells from 1 to 1 million lbf. NVLAP (Lab Code 200662-0) Accredited Force Calibration from 1 gf to 1 million lbf. Industry’s Lowest Across-the-e- Board Specifications Industry’s Most Accurate Metrology Grade Load Cells Experts in High Accuracy Force and Torque Calibration Systems Innovative Engineering Support

TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

  • Upload
    volien

  • View
    254

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

TOVEY ENGINEERINGThe Technical Leader in Load Cells and Force Measurement

The Engineer’s Choice for Force Measurement Products

Force Measurement Solutions for Test Measurement and Metrology Customers.

Call 623-434-5110 For Orders or Information.Or visit http://www.toveyengineering.com

Precision, Fatigue Rated, and Metrology Grade Load Cells from 1 to 1 million lbf.

NVLAP (Lab Code 200662-0) Accredited Force Calibration from 1 gf to 1 million lbf.

Industry’s Lowest Across-the-e-Board Specifications

Industry’s Most AccurateMetrology Grade Load Cells

Experts in High Accuracy Force and Torque Calibration Systems

Innovative Engineering Support

Page 2: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Tovey Engineering shear web products for precision measurement, fatigue testing, and metrology applications incorporate proprietary shear strain technology and refl ect decades of manufacturing expertise in high performance load cells. Shear web products are available in harsh environment and high capacity models. Features of the products include:

> Unsurpassed accuracy in test and metrology applications.

> High resistance to extraneous forces such as side loads, moments, and torque.

> Excellent rejection of the infl uences of thermal gradients and transients.

> Low magnetic fi eld sensitivity.

> Low barometric pressure change sensitivity.

> Very low creep.

> True linearity.

> Symmetry of tension and compression output.

> High stiffness, low defl ection, and high dynamic response.

> High long term stability.

> Extended fatigue life.

Shear Web Load Cells.TOVEY ENGINEERING

Tovey Engineering, Inc. manufactures force transducers with industry leading accuracy, reliability, and quality.

We produce general purpose, fatigue rated, high precision, and metrology grade load cells in a variety of standard sizes and confi gurations from 1lbf to 1 million lbf. We also build special force, force/moment, and torque transducers. Our transducers are designed to perform consistently at high accuracy levels in the most demanding applications and under a variety of environmental conditions.

The Company is focused on the test measurement and metrology markets. We serve fi rms in the aerospace/defense, auto, medical, and measurement industries, as well as government and university research labs.

Force Calibration Services

Tovey Engineering provides NVLAP (Lab Code 200662-0) accredited force calibration services from 1gf to 1 million lbf in compression and to 800,000 lbf in tension with direct traceability to NIST. Calibrations meet requirements of NIST Handbook 150, ISO/IEC 17025, and ANSI Z540. Calibration facilities include both deadweight and hydraulic calibration rigs.

Measurement Systems.

Tovey Engineering provides fully automated complete calibration systems and software for both force and torque transducer calibration. Force systems are available from 20lbf to 1 million lbf. Torque systems are available from 200 in-lb to 100,000 in-lb. We believe these systems are among the most accurate and reliable in the world.

Individually Tested, Compensated, and Calibrated to Meet Stringent Performance and Quality Standards.

Accuracy to .02% of Rated Capacity.

>

>

Page 3: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PRODUCT LINE HIGHLIGHTS

Metrology Grade Load Cells.

Tovey Engineering CS Series calibration standard load cells are designed for metrology lab use. They meet ASTM E74 requirements for Class AA to 10% of range and Class A to 2% of range. We believe they are among the most accurate metrology grade load cells in the world. Supplied to a global customer base. Capacities: 50 to 600,000 lbf.

Fatigue Rated Load Cells.

FR Series fatigue rated load cells are designed for fatigue testing applications and are guaranteed for 100 million fully reversed load cycles. Capacities: 50 to 300,000 lbf.

High Capacity Load Cells.

High capacity load cells are offered in both shear web and column designs and permit high accuracy measurement at the upper end of the capacity scale. Capacities: 100K to 1,000K lbf.

Harsh Environment Load Cells.

Hermetically sealed stainless steel load cells are offered for severe service requirements such as outdoor exposure, extended thermal cycling, or wet or corrosive conditions. Capacities: 5K to 50K lbf.

Compact Load Cells.

S-type and other compactly sized load cells accommodate small test set-ups while reaching reasonable accuracy levels. Capacities: 1 to 20K lbf.

Facilities.

Tovey Engineering maintains integrated design, manufacturing, assembly, test, and calibration facilities for maximum quality control and rapid turnaround on special and custom projects.

Solve your force measurement problem with:

Tovey Engineering Calibration Systems.

Torque Calibration Systems(6,000 in-lbf rig shown).

Force Calibration Systems(11k lbf rig shown).

TOVEY ENGINEERING22602 N. 17th Avenue Phoenix, AZ 85027

623-434-5110 (fax) 623-434-5130http://www.toveyengineering.com

e-mail: [email protected]

Metrology Grade Calibration Standard Load Cells from 50 to 600,000 lbf.

Instruments and System Components.

Fatigue Rated, Standard, and Precision Load Cells from 50 to 600,000 lbf.

The Technical Leader in Load Cells and Force Measurement.

High Capacity Column Load Cells from 100K to 1,000K lbf.

Compact Load Cells from 1 to 20,000 lbf.

Page 4: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PRODUCT CATALOG

TOVEY ENGINEERING

PRODUCTS

TABLE OF CONTENTS

Shear Web (US) (lbf)

Shear Web (Metric) (kN)

Column (lbf)

Compact (lbf)

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Model Capacity Accuracy Page

Stainless Steel (lbf)

Standard SW 300 - 100K .04 - .05 1Standard High Capacity SW 200K - 600K .07 - .12 3Standard Compression Only SW 300 - 200K .03 - .05 5Fatigue Rated FR 150 - 50K .03 - .05 7Fatigue Rated High Capacity FR 100K - 300K .06 - .10 9Precision SWP 300 - 100K .02 - .04 11Precision High Capacity SWP 200K - 600K .05 - .10 13Calibration Standard CS 300 - 100K .02 - .04 15Calibration Standard High Capacity CS 200K - 600K .05 - .10 17

Standard SW - M 1.5 - 500 .04 - .05 19Standard High Capacity SW - M 1000 - 2700 .07 - .12 21Standard Compression Only SW - M 1.5 - 1000 .03 - .05 23Fatigue Rated FR - M 1.25 - 250 .03 - .05 25Fatigue Rated High Capacity FR - M 500 - 1350 .06 - .10 27Precision SWP - M 1.5 - 500 .02 - .04 29Precision High Capacity SWP - M 1000 - 2700 .05 - .10 31Calibration Standard CS - M 1.5 - 500 .02 - .04 33Calibration Standard High Capacity CS - M 1000 - 2700 .05 - .10 35

Universal Column High Capacity 5000 100K - 1000K .2 37Compression Column High Capacity 5100 100K - 1000K .2 39Universal 4 Column High Capacity 5200 100K - 500K .1 41Heavy Duty Fatigue Rated XHD 55K - 550K .05 - .08 43

Premium S-Type SSC 50 - 5K .03 45Fatigue Rated S-Type RSC 100 - 1K .03 46Overload Protected S-Type SCT 2 - 110 .02 47Precision S-Type ZXT 50 - 20K .03 48Low Height S-Beam SLH 5 - 1K .05 - .10 49Fatigue Rated Mini FR5 50 - 300 .05 50Mini Column 2029 500 - 7.5K .25 51Load Washers LW 2K - 10K .5 52

Stainless Steel Shear Web SWS 5K - 100K .05 - .08 53Fatigue Stainless Shear Web FRS 2.5K - 25K .05 - .08 55Low Height Stainless 4110 500 - 5K .10 57General Purpose Stainless 4120 10K - 20K .10 59Low Height Compression Column 2100 10K - 25K .07 61

Page 5: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

TOVEY ENGINEERING

PRODUCTS

TABLE OF CONTENTS

(lbf / in.-lb or in-lb)

THE ENGINEER’S CHOICE FOR FORCE MEASUREMENT PRODUCTS

Model Capacity Accuracy Page

Multi-Axis and Torque

Instruments

SERVICES

SYSTEMS

Load Cell Simulators

Accessories and Options

SOFTWARE

TERMS

Axial Force and Torque SWT 300/150 - 5K/2K .04/.05-.07 62Axial Force and Moment SW-XYZ 1K/500 - 100K/50K .04-.05/1 63Miniature Reaction Torque RT 25 - 500 .10 64

General Purpose Indicator 7010 ----- 0.01 65Sealed Indicator 7120 ----- 0.01 66High Precision Indicator 9150 ----- 0.005 67Digital Signal Conditioner 9250 ----- 0.01 68Rugged Signal Conditioner (2kHz) 460 ----- 0.1 69Rugged Signal Conditioner 465 ----- 0.1 70Portable Indicator 7230 ----- 0.005 71Strain Gage Amplifier SGA ----- 0.01 72Load Cell Instrument Modules 7500 ----- ----- 73

Reference Std. Simulator TS-10-2 ----- 0.003 74

Load Buttons LB ----- ----- 75Compression Plates CP ----- ----- 75Calibration Adapters TAMM ----- ----- 76Thread Adapters TAMF ----- ----- 76Couplers and Jam Nuts TAFF/JN ----- ----- 77Interconnect Cables and Connectors CBL/MC ----- ----- 78Options Description ----- ----- ----- 79

Calibration and Test Software ----- ----- ----- 80

Calibration Services ----- ----- ----- 81

Force Calibration Systems ----- ----- ----- 83Torque Calibration Systems ----- ----- ----- 85

Terms and Conditions & Warranty ----- ----- ----- 86

Page 6: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

SHEAR WEB (SW) SERIES FORCE TRANSDUCERS

SHEAR WEB LOAD CELLS

FEATURES

Static Error Band, % R.O. +/-.04 +/-.05 +/-.05 +/-.05Nonlinearity, % R.O. +/-.04 +/-.05 +/-.05 +/-.05Hysteresis, % R.O. +/-.03 +/-.05 +/-.05 +/.05Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.25 +/-.25 +/-.25 +/-.25Side Load Sensitivity, % +/-.25 +/-.25 +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.15 +/-.15 +/-.15 +/-.15

Rated Output, mV/V, Nominal 2.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (lbs.) 1.0 2.9 9.1 23.5Weight w/base (lbs.) 2.5 6.5 21.5 52.5Flexure Material Aluminum Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

First Choice for Structural and Materials TestingLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsBarometric Pressure CompensationOutput to 4mV/VBayonet Connector

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 1

SW10 SW10 SW20 SW30

300, 500 1K, 2K 5K, 10K 25K, 50K 100K

Page 7: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)

1. Height Total 2.56 2.56 3.67 4.65 2. Max. Clearance Radius 2.53 2.53 3.50 4.50 3. Cell and Base Diameter 4.12 4.12 6.06 8.00 4. Cell Height to Hub 1.38 1.38 1.75 2.50 5. Cell Body Height 1.25 1.25 1.63 2.25 6. Hub Diameter 1.29 1.29 2.34 25K/2.58 50K 3.76 7. Mounting B.C. Diameter 3.50 3.50 5.13 6.50 8. Symmetric B.C. Offset 22.5 Degrees 22.5 Degrees 15 Degrees 11.25 Degrees 9. Mounting Hole Diameter .28 .28 .41 .53 10. Hub Thread 1/2 - 20, 1.12 Dp. 5/8 - 18, 1.12 Dp. 1 1/4 - 12, 1.50 Dp. 1 3/4 - 12, 2.20 Dp. 11. Bolt Head Protrusion .18 .18 .29 .40 12. Base Thickness 1.13 1.13 1.75 2.00 13. Base Step Height .03 .03 .03 .03 14. Base Step Diameter 1.25 1.25 2.25 3.00 15. Base Thread 1/2 20, .88 Dp. 5/8 - 18, .88 Dp. 1 1/4 - 12, 1.50 Dp. 1 3/4 - 12, 1.75 Dp.

Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 2

SW10 SW10 SW20 SW30

300, 500 1K, 2K 5K, 10K 25K, 50K 100K

Page 8: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

FEATURESFirst Choice for Structural and Materials TestingLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsBarometric Pressure CompensationOutput 4mV/VBayonet Connector

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 3

SW40 SW42 SW60 SW60

200K 270K 500K 600K

Static Error Band, % R.O. +/-.07 +/-.07 +/-.12 +/-.12Hysteresis, % R.O. +/-.07 +/-.08 +/-.12 +/-.12Nonlinearity, % R.O. +/-.07 +/-.08 +/-.12 +/.12Nonrepeatability, % R.O. +/-.01 +/-.02 +/-.02 +/-.02Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.25 +/-.25 +/-.25 +/-.25Side Load Sensitivity, % +/-.25 +/-.25 +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.15 +/-.15 +/-.15 +/-.15

Rated Output, mV/V, Nominal 4.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (lbs.) 74 84 245 245Weight w/base (lbs.) 146 156 448 448Flexure Material Steel Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

HIGH CAPACITY SHEAR WEB (SW) SERIES FORCE TRANSDUCERS

Page 9: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 4

SW40 SW42 SW60 SW60

200K 270K 500K 600K

1. Height Total 6.60 7.10 9.57 9.57 2. Max. Clearance Radius 6.16 6.16 8.65 8.65 3. Cell and Base Diameter 11.00 11.00 16.00 16.00 4. Cell Height to Hub 3.50 4.00 5.25 5.25 5. Cell Body Height 3.00 3.50 4.75 4.75 6. Hub Diameter 4.81 4.81 7.89 7.89 7. Mounting B.C. Diameter 9.00 9.00 13.06 13.06 8. Symmetric B.C. Offset 11.25 degrees 11.25 degrees 9.00 degrees 9.00 degrees 9. Mounting Hole Diameter .78 .78 1.18 1.18 10. Hub Thread 2 3/4 - 8, 3.2 Dp. 2 3/4 - 8, 3.7 Dp. 4 - 8, 4.75 Dp. 4 - 8, 4.75 Dp. 11. Bolt Head Protrusion .60 .60 .82 .82 12. Base Thickness 3.00 3.00 4.00 4.00 13. Base Step Height .03 .03 .03 .03 14. Base Step Diameter 4.83 4.83 7.89 7.89 15. Base Thread 2 ¾ - 8, 2.70 Dp. 2 ¾ - 8, 2.70 Dp. 4 - 8, 3.65 Dp. 4 - 8, 3.65 Dp.

Page 10: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

SHEAR WEB (SW) SERIES COMPRESSION ONLY FORCE TRANSDUCERS

SHEAR WEB LOAD CELLS

FEATURES

Static Error Band, % R.O. +/-.03 +/-.04 +/-.04 +/-.04 +/-.05Nonlinearity, % R.O. +/-.03 +/-.04 +/-.05 +/-.05 +/-.05Hysteresis, % R.O. +/-.03 +/-.04 +/-.05 +/.05 +/-.05Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.25 +/-.25 +/-.25 +/-.25 +/-.25Side Load Sensitivity, % +/-.25 +/-.25 +/-.25 +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.15 +/-.15 +/-.15 +/-.15 +/-.15

Rated Output, mV/V, Nominal 2.0 4.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10 10Input Resistance, Ohms 350 350 350 350 350Output Resistance, Ohms 350 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150 +/-150Weight (lbs.) 1.1 3.1 5.1 9 33Weight w/base (lbs.) 2.6 6.7 11 21 70Flexure Material Aluminum Steel Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

Compact SizeLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsCounterbored Mounting Holes (w/out Base)Output to 4mV/VIntegral Compression Interface (above 10K)

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 5

SW11 SW11 SW21 SW31 SW41

300, 500, 1K, 2K 5K, 10K 25K, 50K 100K 200K

Page 11: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)

1. Height Total See SW 3.00 4.49 5.75 2. Max. Clearance Radius Add Compatible 2.84 3.51 4.61 3. Cell and Base Diameter Load Button 4.75 6.06 8.25 4. Cell Height to Button 1.75 2.50 3.25 5. Cell Body Height 1.63 2.25 3.00 6. Compression Button Diameter 1.56 2.58 3.16 7. Mounting B.C. Diameter 4.00 5.13 6.75 8. Symmetric B.C. Offset 45 Degrees 15 Degrees 15 Degrees 9. Mounting Hole Dia. (w/out Base) C’Bore for 5/16-24 C’Bore for 3/8-24 C’Bore for 5/8-18 10. Comp. Button Sph. Radius 6 8 12 11. Base Thickness 1.25 2.00 2.50 12. Base Step Height .03 .03 .03 13. Base Step Diameter 3.38 4.38 5.75 14. Base Thread 1/2- 20, 1.00 Dp. 3/4-16, 2.25 Dp. 3/4 - 16, 2.25 Dp.

Review Drawing(in inches)

DIMENSIONS

3

5

89

10

11

12

14

15

1

13

6

4

27

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 6

SW11 SW21 SW31 SW41

300, 500, 1K 2K, 5K, 10K 25K, 50K 100K 200K

Page 12: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

FR10 FR10 FR20 FR30

150, 250 500, 1K 2.5K, 5K 12.5K, 25K 50K

FATIGUE RATED (FR) SERIESFORCE TRANSDUCERS

FEATURESFirst Choice for Fatigue Testing ApplicationsGuaranteed for 100 Million Fully Reversed CyclesLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsBarometric Pressure Compensation

Page 7

Static Error Band, % R.O. +/-.03 +/-.04 +/-.05 +/-.05Nonlinearity, % R.O. +/-.04 +/-.04 +/-.05 +/-.05Hysteresis, % R.O. +/-.03 +/-.04 +/-.05 +/.05Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.10 +/-.10 +/-.10 +/-.10Side Load Sensitivity, % +/-.10 +/-.10 +/-.10 +/-.10Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.15 +/-.15 +/-.15 +/-.15

Rated Output, mV/V, Nominal 1.0 2.0 2.0 2.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-300 +/-300 +/-300 +/-300Weight (lbs.) 1.0 2.9 9.1 23.5Weight w/base (lbs.) 2.5 6.5 21.5 52.5Flexure Material Aluminum Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

Page 13: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)

1. Height Total 2.56 2.56 3.67 4.65 2. Max. Clearance Radius 2.53 2.53 3.50 4.50 3. Cell and Base Diameter 4.12 4.12 6.06 8.00 4. Cell Height to Hub 1.38 1.38 1.75 2.50 5. Cell Body Height 1.25 1.25 1.63 2.25 6. Hub Diameter 1.29 1.29 2.34 25K/2.58 50K 3.76 7. Mounting B.C. Diameter 3.50 3.50 5.13 6.50 8. Symmetric B.C. Offset 22.5 Degrees 22.5 Degrees 15 Degrees 11.25 Degrees 9. Mounting Hole Diameter .28 .28 .41 .53 10. Hub Thread 1/2 - 20, 1.12 Dp. 5/8 - 18, 1.12 Dp. 1 1/4 - 12, 1.50 Dp. 1 3/4 - 12, 2.20 Dp. 11. Bolt Head Protrusion .18 .18 .29 .40 12. Base Thickness 1.13 1.13 1.75 2.00 13. Base Step Height .03 .03 .03 .03 14. Base Step Diameter 1.25 1.25 2.25 3.00 15. Base Thread 1/2 20, .88 Dp. 5/8 - 18, .88 Dp. 1 1/4 - 12, 1.50 Dp. 1 3/4 - 12, 1.75 Dp.

Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 8

FR10 FR10 FR20 FR30

150, 250 500, 1K 2.5K, 5K 12.5K, 25K 50K

Page 14: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 9

FR40 FR42 FR60 FR60

100K 135K 250K 300K

Static Error Band, % R.O. +/-.06 +/-.07 +/-.10 +/-.10Hysteresis, % R.O. +/-.06 +/-.08 +/-.10 +/-.10Nonlinearity, % R.O. +/-.06 +/-.08 +/-.10 +/.10Nonrepeatability, % R.O. +/-.01 +/-.02 +/-.02 +/-.02Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.25 +/-.25 +/-.25 +/-.25Side Load Sensitivity, % +/-.25 +/-.25 +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Rated Output, mV/V, Nominal 2.0 2.0 2.0 2.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Mechanical

Electrical

Temperature

Accuracy

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.15 +/-.15 +/-.15 +/-.15

Safe Overload Range, % R.O. +/-300 +/-300 +/-300 +/-300Weight (lbs.) 74 84 245 245Weight w/base (lbs.) 146 156 448 448Flexure Material Steel Steel Steel Steel

HIGH CAPACITY FATIGUE RATED (FR) SERIES FORCE TRANSDUCERS

FEATURESFirst Choice for Fatigue Testing ApplicationsGuaranteed for 100 Million Fully Reversed CyclesLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsBarometric Pressure Compensation

Page 15: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 10

FR40 FR42 FR60 FR60

100K 135K 250K 300K

1. Height Total 6.60 7.10 9.57 9.57 2. Max. Clearance Radius 6.16 6.16 8.65 8.65 3. Cell and Base Diameter 11.00 11.00 16.00 16.00 4. Cell Height to Hub 3.50 4.00 5.25 5.25 5. Cell Body Height 3.00 3.50 4.75 4.75 6. Hub Diameter 4.81 4.81 7.89 7.89 7. Mounting B.C. Diameter 9.00 9.00 13.06 13.06 8. Symmetric B.C. Offset 11.25 degrees 11.25 degrees 9.00 degrees 9.00 degrees 9. Mounting Hole Diameter .78 .78 1.18 1.18 10. Hub Thread 2 3/4 - 8, 3.2 Dp. 2 3/4 - 8, 3.7 Dp. 4 - 8, 4.75 Dp. 4 - 8, 4.75 Dp. 11. Bolt Head Protrusion .60 .60 .82 .82 12. Base Thickness 3.00 3.00 4.00 4.00 13. Base Step Height .03 .03 .03 .03 14. Base Step Diameter 4.83 4.83 7.89 7.89 15. Base Thread 2 ¾ - 8, 2.70 Dp. 2 ¾ - 8, 2.70 Dp. 4 - 8, 3.65 Dp. 4 - 8, 3.65 Dp.

Page 16: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 11

SWP10 SWP10 SWP20 SWP30

300, 500 1K, 2K 5K, 10K 25K, 50K 100K

Static Error Band, % R.O. +/-.02 +/-.03 +/-.04 +/-.04Nonlinearity, % R.O. +/-.03 +/-.03 +/-.03 +/-.03Hysteresis, % R.O. +/-.02 +/-.04 +/-.04 +/.04Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.10 +/-.10 +/-.10 +/-.10Side Load Sensitivity, % +/-.10 +/-.10 +/-.10 +/-.10Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.08 +/-.08 +/-.08 +/-.08

Rated Output, mV/V, Nominal 2.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (lbs.) 1.0 2.9 9.1 23.5Weight w/base (lbs.) 2.5 6.5 21.5 52.5Flexure Material Aluminum Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

SHEAR WEB PRECISION (SWP) SERIES FORCE TRANSDUCERSFEATURES

High Accuracy Version of SW SeriesLow HeightSmaller Guaranteed Maximum Off-Center Load and Moment Error than SW SeriesStatic Error Band .02-.04%Low CreepLow Sensitivity to Magnetic FieldsBarometric Pressure CompensationTemperature CompensatedOutput to 4 mV/V

Page 17: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)

1. Height Total 2.56 2.56 3.67 4.65 2. Max. Clearance Radius 2.53 2.53 3.50 4.50 3. Cell and Base Diameter 4.12 4.12 6.06 8.00 4. Cell Height to Hub 1.38 1.38 1.75 2.50 5. Cell Body Height 1.25 1.25 1.63 2.25 6. Hub Diameter 1.29 1.29 2.34 25K/2.58 50K 3.76 7. Mounting B.C. Diameter 3.50 3.50 5.13 6.50 8. Symmetric B.C. Offset 22.5 Degrees 22.5 Degrees 15 Degrees 11.25 Degrees 9. Mounting Hole Diameter .28 .28 .41 .53 10. Hub Thread 1/2 - 20, 1.12 Dp. 5/8 - 18, 1.12 Dp. 1 1/4 - 12, 1.50 Dp. 1 3/4 - 12, 2.20 Dp. 11. Bolt Head Protrusion .18 .18 .29 .40 12. Base Thickness 1.13 1.13 1.75 2.00 13. Base Step Height .03 .03 .03 .03 14. Base Step Diameter 1.25 1.25 2.25 3.00 15. Base Thread 1/2 20, .88 Dp. 5/8 - 18, .88 Dp. 1 1/4 - 12, 1.50 Dp. 1 3/4 - 12, 1.75 Dp.

Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 12

SWP10 SWP10 SWP20 SWP30

300, 500 1K, 2K 5K, 10K 25K, 50K 100K

Page 18: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

FEATURESHigh Accuracy at High CapacityLow HeightLow Guaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsTemperature CompensatedBarometric Pressure CompensationOutput 4mV/V

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 13

SWP40 SWP42 SWP60 SWP60

200K 270K 500K 600K

Static Error Band, % R.O. +/-.05 +/-.06 +/-.10 +/-.10Hysteresis, % R.O. +/-.05 +/-.06 +/-.10 +/-.10Nonlinearity, % R.O. +/-.05 +/-.06 +/-.10 +/.10Nonrepeatability, % R.O. +/-.005 +/-.005 +/-.01 +/-.01Creep, % in 20 minutes +/-.01 +/-.015 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.1 +/-.1 +/-.2 +/-.2Side Load Sensitivity, % +/-.1 +/-.1 +/-.2 +/-.2Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.08 +/-..08 +/-.08 +/-.08

Rated Output, mV/V, Nominal 4.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (lbs.) 74 84 245 245Weight w/base (lbs.) 146 156 448 448Flexure Material Steel Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

HIGH CAPACITY SHEAR WEB PRECISION (SWP) SERIES FORCE TRANSDUCERS

Page 19: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 14

SWP40 SWP42 SWP60 SWP60

200K 270K 500K 600K

1. Height Total 6.60 7.10 9.57 9.57 2. Max. Clearance Radius 6.16 6.16 8.65 8.65 3. Cell and Base Diameter 11.00 11.00 16.00 16.00 4. Cell Height to Hub 3.50 4.00 5.25 5.25 5. Cell Body Height 3.00 3.50 4.75 4.75 6. Hub Diameter 4.81 4.81 7.89 7.89 7. Mounting B.C. Diameter 9.00 9.00 13.06 13.06 8. Symmetric B.C. Offset 11.25 degrees 11.25 degrees 9.00 degrees 9.00 degrees 9. Mounting Hole Diameter .78 .78 1.18 1.18 10. Hub Thread 2 3/4 - 8, 3.2 Dp. 2 3/4 - 8, 3.7 Dp. 4 - 8, 4.75 Dp. 4 - 8, 4.75 Dp. 11. Bolt Head Protrusion .60 .60 .82 .82 12. Base Thickness 3.00 3.00 4.00 4.00 13. Base Step Height .03 .03 .03 .03 14. Base Step Diameter 4.83 4.83 7.89 7.89 15. Base Thread 2 ¾ - 8, 2.70 Dp. 2 ¾ - 8, 2.70 Dp. 4 - 8, 3.65 Dp. 4 - 8, 3.65 Dp.

Page 20: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 15

CS10 CS10 CS20 CS30

300, 500 1K, 2K 5K, 10K 25K, 50K 100K

Lower Load Limit % of R.O. 2.0 2.0 2.0 2.0Static Error Band, % R.O. +/-.02 +/-.03 +/-.03 +/-.03Nonlinearity, % R.O. +/-.02 +/-.03 +/-.03 +/-.03Hysteresis, % R.O. +/-.02 +/-.04 +/-.04 +/.04Nonrepeatability, % R.O. +/-.005 +/-.005 +/-.005 +/-.005Creep, % in 20 minutes +/-.015 +/-.015 +/-.015 +/-.015Off-Center Load Sensitivity, %/inch +/-.05 +/-.05 +/-.05 +/-.05Side Load Sensitivity, % +/-.05 +/-.05 +/-.05 +/-.05Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.08 +/-.08 +/-.08 +/-.08

Rated Output, mV/V, Nominal 2.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (lbs.) 2.8 6.9 23.6 57.8Flexure Material Aluminum Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

CALIBRATION STANDARD (CS) SERIESFORCE TRANSDUCERS

Designed for Metrology Lab UseMeets ASTM E74 Requirements Class AA to 10% of Range (Most Models) Class A to 2% of RangeLowest CreepLowest Sensitivity to Rotation ErrorLowest Sensitivity to Reproducibility ErrorsAll Features Meet or Exceed SWP-M Series

FEATURES

Page 21: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 16

CS10 CS10 CS20 CS30

300, 500 1K, 2K 5K, 10K 25K, 50K 100K

1. Height Total 4.13 4.13 6.32 7.85 2. Max. Clearance Radius 2.53 2.53 3.50 4.50 3. Cell and Base Diameter 4.12 4.12 6.06 8.00 4. Cell and Base Height (to Hub) 2.51 2.51 3.50 4.25 5. Bolt Head Protrusion .18 .18 .29 .40 6. Base Step Height .03 .03 .03 .03 7. Base Step Diameter 1.25 1.25 2.25 3.00 8. Base Thread 1/2 - 20, .88 Dp. 5/8 - 18, .88 Dp. 1 1/4 - 12, 1.50 Dp. 1 3/4 - 12, 1.75 Dp. 9. Adapter Thread 1/2 - 20 5/8 - 18 1 1/4 - 12 1 3/4 - 12 10. Adapter Thread Depth .75 .75 1.50 1.75 11. Adapter End Radius 6.00 6.00 6.00 12.00 12. Connector MS3112_E10 MS3112_E10 MS3112_E10 MS3112_E10 w/protector

Page 22: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 17

CS40 CS42 CS60 CS60

200K 270K 500K 600K

Lower Load Limit % of R.O. 4.0 4.0 4.0 4.0Static Error Band, % R.O. +/-.05 +/-.06 +/-.10 +/-.10Hysteresis, % R.O. +/-.05 +/-.06 +/-.10 +/-.10Nonlinearity, % R.O. +/-.05 +/-.06 +/-.10 +/.10Nonrepeatability, % R.O. +/-.005 +/-.005 +/-.01 +/-.01Creep, % in 20 minutes +/-.01 +/-.015 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.1 +/-.1 +/-.2 +/-.2Side Load Sensitivity, % +/-.1 +/-.1 +/-.2 +/-.2Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.08 +/-.08 +/-.08 +/-.08

Rated Output, mV/V, Nominal 4.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Mechanical

Electrical

Temperature

Accuracy

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (lbs.) 166 176 519 519Flexure Material Aluminum Steel Steel Steel

HIGH CAPACITY CALIBRATION STANDARD (CS) SERIES FORCE TRANSDUCERS

FEATURESDesigned for Metrology Lab UseMeets ASTM E74 Requirements Class A to 4% of RangeGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Sensitivity to Rotation ErrorLow Sensitivity to Reproducibility ErrorsLow Susceptibility to Magnetic Fields

Page 23: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 18

CS40 CS42 CS60 CS60

200K 270K 500K 600K

1. Height Total 11.58 12.08 16.63 16.63 2. Max. Clearance Radius 6.16 6.16 8.65 8.65 3. Cell and Base Diameter 11.00 11.00 16.00 16.00 4. Cell and Base Height (to Hub) 6.50 7.00 9.25 9.25 5. Bolt Head Protrusion .60 .60 .82 .82 6. Base Step Height .03 .03 .03 .03 7. Base Step Diameter 4.83 4.83 7.89 7.89 8. Base Thread 2 ¾ - 8, 2.70 Dp. 2 ¾ - 8, 2.70 Dp. 4 - 8, 3.65 Dp. 4 - 8, 3.65 Dp. 9. Adapter Thread 2 ¾ - 8 2 ¾ - 8 4 - 8 4 - 8 10. Adapter Thread Depth 2.50 2.50 3.50 3.50 11. Adapter End Radius 12 12 20 20 12. Connector MS3112_E10 MS3112_E10 MS3112_E10 MS3112_E10 w/protector w/protector w/protector w/protector

Page 24: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (kN)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 19

SW10M SW10M SW20M SW30M

1.5, 2.5 5, 10 25, 50 100, 250 500

SHEAR WEB METRIC (SW - M) SERIES FORCE TRANSDUCERS

First Choice for Structural and Materials TestingLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsBarometric Pressure CompensationOutput to 4mV/VBayonet Connector

FEATURES

Static Error Band, % R.O. +/-.04 +/-.05 +/-.05 +/-.05Nonlinearity, % R.O. +/-.04 +/-.05 +/-.05 +/-.05Hysteresis, % R.O. +/-.03 +/-.05 +/-.05 +/.05Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.25 +/-.25 +/-.25 +/-.25Side Load Sensitivity, % +/-.25 +/-.25 +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °C -10 to +45 -10 to +45 -10 to +45 -10 to +45Range, Operating, °C -55 to +90 -55 to +90 -55 to +90 -55 to +90Effect on Sensitivity, % Rdg/100°C +/-.15 +/-.15 +/-.15 +/-.15Effect on Zero, % R.O./100°C +/-.27 +/-.27 +/-.27 +/-.27

Rated Output, mV/V, Nominal 2.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight, kg (lbs.) .45 (1.0) 1.30 (2.9) 4.13 (9.1) 10.66 (23.5)Weight w/base, kg (lbs.) 1.13 (2.5) 2.95 (6.5) 9.75 (21.5) 23.81 (52.5)Flexure Material Aluminum Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

Page 25: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (kN)Review Drawing(in mm)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 20

SW10M SW10M SW20M SW30M

1. Height Total 65.0 65.0 93.2 118.1 2. Max. Clearance Radius 64.3 64.3 88.9 114.3 3. Cell and Base Diameter 104.8 104.8 154.0 203.2 4. Cell Height to Hub 34.9 34.9 44.5 63.5 5. Cell Body Height 31.8 31.8 41.4 57.2 6. Hub Diameter 32.8 32.8 65.5 95.5 7. Mounting B.C. Diameter 88.9 88.9 130.3 130.3 8. Symmetric B.C. Offset 22.5 degrees 22.5 degrees 15.0 degrees 11.25 degrees 9. Mounting Hole Diameter 7.1 7.1 10.4 13.5 10. Hub Thread M12 x 1.25, 28.5 Dp. M16 x 2, 28.5 Dp. M33 x 2, 38.1 Dp. M42 x 2, 55.9 Dp. 11. Bolt Head Protrusion 4.5 4.5 7.3 10.1 12. Base Thickness 28.7 28.7 44.5 50.8 13. Base Step Height .8 .8 .8 .8 14. Base Step Diameter 31.8 31.8 57.2 76.2 15. Base Thread M12 x 1.25, 22.4 Dp. M16 x 2, 22.4 Dp. M33 x 2, 38.1 Dp. M42 x 2, 44.5 Dp.

1.5, 2.5 5, 10 25, 50 100, 250 500

Page 26: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (kN)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

FEATURESFirst Choice for Structural and Materials TestingLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsBarometric Pressure CompensationOutput 4mV/VBayonet Connector

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 21

SW40M SW42M SW60M SW60M

1000 1200 2200 2700

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (kg) 34 38 111 111Weight w/base (kg) 66 71 203 203Flexure Material Steel Steel Steel Steel

Mechanical

Static Error Band, % R.O. +/-.07 +/-.07 +/-.12 +/-.12Hysteresis, % R.O. +/-.07 +/-.08 +/-.12 +/-.12Nonlinearity, % R.O. +/-.07 +/-.08 +/-.12 +/.12Nonrepeatability, % R.O. +/-.01 +/-.02 +/-.02 +/-.02Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.25 +/-.25 +/-.25 +/-.25Side Load Sensitivity, % +/-.25 +/-.25 +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °C -10 to +45 -10 to +45 -10 to +45 -10 to +45Range, Operating, °C -55 to +90 -55 to +90 -55 to +90 -55 to +90Effect on Sensitivity, % Rdg/100°C +/-.15 +/-.15 +/-.15 +/-.15Effect on Zero, % R.O./100°C +/-.30 +/-.30 +/-.30 +/-.30

Rated Output, mV/V, Nominal 4.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Electrical

Temperature

Accuracy

HIGH CAPACITY SHEAR WEB METRIC (SW - M) SERIES FORCE TRANSDUCERS

Page 27: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (kN)Review Drawing(in mm)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 22

SW40M SW42M SW60M SW60M

1000 1200 2200 2700

1. Height Total 167.6 180.3 243.1 243.1 2. Max. Clearance Radius 156.4 156.4 219.7 219.7 3. Cell and Base Diameter 279.4 279.4 406.4 406.4 4. Cell Height to Hub 88.9 101.6 133.3 133.3 5. Cell Body Height 76.2 88.9 120.6 120.6 6. Hub Diameter 122.2 122.2 200.4 200.4 7. Mounting B.C. Diameter 228.6 228.6 331.6 331.6 8. Symmetric B.C. Offset 11.25 degrees 11.25 degrees 9 degrees 9 degrees 9. Mounting Hole Diameter 19.8 19.8 30.0 30.0 10. Hub Thread M72 x 2, 81.3 Dp. M72 x 2, 94.0 Dp. M100 x 3, 120.6 Dp. M100 x 3, 120.6 Dp. 11. Bolt Head Protrusion 15.2 15.2 20.8 20.8 12. Base Thickness 76.2 76.2 101.6 101.6 13. Base Step Height .8 .8 .8 .8 14. Base Step Diameter 122.7 122.7 200.4 200.4 15. Base Thread M72 x 2, 68.6 Dp. M72 x 2, 68.6 Dp. M100 x 3, 92.7 Dp. M100 x 3, 92.7 Dp.

Page 28: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (kN)

SPECIFICATIONS

SHEAR WEB METRIC (SW - M) SERIES COMPRESSION ONLY FORCE TRANSDUCERS

SHEAR WEB LOAD CELLS

FEATURES

Static Error Band, % R.O. +/-.03 +/-.04 +/-.04 +/-.04 +/-.05Nonlinearity, % R.O. +/-.03 +/-.04 +/-.05 +/-.05 +/-.05Hysteresis, % R.O. +/-.03 +/-.04 +/-.05 +/.05 +/-.05Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.25 +/-.25 +/-.25 +/-.25 +/-.25Side Load Sensitivity, % +/-.25 +/-.25 +/-.25 +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °C -10 to +45 -10 to +45 -10 to +45 -10 to +45 -10 to +45Range, Operating, °C -55 to +90 -55 to +90 -55 to +90 -55 to +90 -55 to +90Effect on Sensitivity, % Rdg/100°C +/-.15 +/-.15 +/-.15 +/-.15 +/-.15Effect on Zero, % R.O./100°C +/-.27 +/-.27 +/-.27 +/-.27 +/-.27

Rated Output, mV/V, Nominal 2.0 4.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10 10Input Resistance, Ohms 350 350 350 350 350Output Resistance, Ohms 350 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150 +/-150Weight (kg) 0.5 1.4 2.3 4 15Weight w/base (kg) 1.2 3.0 5.0 10 32Flexure Material Aluminum Steel Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

Compact SizeLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsCounterbored Mounting Holes (w/out Base)Output to 4mV/VIntegral Compression Interface (above 50 kN)

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 23

SW11M SW11M SW21M SW31M SW41M

1.5, 2.5, 5, 10 25, 50 100, 250 500 1000

Page 29: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (kN)

1. Height Total See SW - M 76.2 4.49 5.75 2. Max. Clearance Radius Add Compatible 72.1 3.51 4.61 3. Cell and Base Diameter Load Button 120.7 6.06 8.25 4. Cell Height to Button 44.5 2.50 3.25 5. Cell Body Height 41.4 2.25 3.00 6. Compression Button Diameter 39.6 2.58 3.16 7. Mounting B.C. Diameter 101.6 5.13 6.75 8. Symmetric B.C. Offset 45 Degrees 15 Degrees 15 Degrees 9. Mounting Hole Dia. (w/out Base) C’Bore for M8 C’Bore for M10 C’Bore for M16 10. Comp. Button Sph. Radius 150 300 300 11. Base Thickness 31.8 50.8 63.5 12. Base Step Height .8 .8 .8 13. Base Step Diameter 85.9 111.3 146.1 14. Base Thread M12 x 1.25 , 25 Dp. M27 x 2, 56 Dp. M27 x 2, 56 Dp.

Review Drawing(in mm)

DIMENSIONS

3

5

89

10

11

12

14

15

1

13

6

4

27

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 24

SW11M SW21M SW31M SW41M

1.25, 2.5, 5 10, 25, 50 100, 250 500 1000

Page 30: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (kN)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 25

FR10M FR10M FR20M FR30M

1.25 2.5, 5 12.5, 25 50, 125 250

Static Error Band, % R.O. +/-.03 +/-.04 +/-.05 +/-.05Nonlinearity, % R.O. +/-.04 +/-.04 +/-.05 +/-.05Hysteresis, % R.O. +/-.03 +/-.04 +/-.05 +/.05Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.10 +/-.10 +/-.10 +/-.10Side Load Sensitivity, % +/-.10 +/-.10 +/-.10 +/-.10Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °C -10 to +45 -10 to +45 -10 to +45 -10 to +45Range, Operating, °C -55 to +90 -55 to +90 -55 to +90 -55 to +90Effect on Sensitivity, % Rdg/100°C +/-.15 +/-.15 +/-.15 +/-.15Effect on Zero, % R.O./100°C +/-.27 +/-.27 +/-.27 +/-.27

Rated Output, mV/V, Nominal 1.0 2.0 2.0 2.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-300 +/-300 +/-300 +/-300Weight, kg (lbs.) .45 (1.0) 1.30 (2.9) 4.13 (9.1) 10.66 (23.5)Weight w/base, kg (lbs.) 1.13 (2.5) 2.95 (6.5) 9.75 (21.5) 23.81 (52.5)Flexure Material Aluminum Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

FATIGUE RATED SHEAR WEB METRIC (FR - M) SERIES FORCE TRANSDUCERS

Fatigue RatedGuaranteed for 100 Million Fully Reversed Load CyclesLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsTemperature CompensatedBarometric Pressure Compensation

FEATURES

Page 31: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (kN)Review Drawing(in mm)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 26

FR10M FR10M FR20M FR30M

1. Height Total 65.0 65.0 93.2 118.1 2. Max. Clearance Radius 64.3 64.3 88.9 114.3 3. Cell and Base Diameter 104.8 104.8 154.0 203.2 4. Cell Height to Hub 34.9 34.9 44.5 63.5 5. Cell Body Height 31.8 31.8 41.4 57.2 6. Hub Diameter 32.8 32.8 65.5 95.5 7. Mounting B.C. Diameter 88.9 88.9 130.3 130.3 8. Symmetric B.C. Offset 22.5 degrees 22.5 degrees 15.0 degrees 11.25 degrees 9. Mounting Hole Diameter 7.1 7.1 10.4 13.5 10. Hub Thread M12 x 1.25, 28.5 Dp. M16 x 2, 28.5 Dp. M33 x 2, 38.1 Dp. M42 x 2, 55.9 Dp. 11. Bolt Head Protrusion 4.5 4.5 7.3 10.1 12. Base Thickness 28.7 28.7 44.5 50.8 13. Base Step Height .8 .8 .8 .8 14. Base Step Diameter 31.8 31.8 57.2 76.2 15. Base Thread M12 x 1.25, 22.4 Dp. M16 x 2, 22.4 Dp. M33 x 2, 38.1 Dp. M42 x 2, 44.5 Dp.

1.25 2.5, 5 12.5, 25 50, 125 250

Page 32: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (kN)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 27

FR40M FR42M FR60M FR60M

500 600 1100 1350

Safe Overload Range, % R.O. +/-300 +/-300 +/-300 +/-300Weight (kg) 34 38 111 111Weight w/base (kg) 66 71 203 203Flexure Material Steel Steel Steel Steel

Mechanical

Static Error Band, % R.O. +/-.06 +/-.07 +/-.10 +/-.10Hysteresis, % R.O. +/-.06 +/-.08 +/-.10 +/-.10Nonlinearity, % R.O. +/-.06 +/-.08 +/-.10 +/.10Nonrepeatability, % R.O. +/-.01 +/-.02 +/-.02 +/-.02Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.25 +/-.25 +/-.25 +/-.25Side Load Sensitivity, % +/-.25 +/-.25 +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °C -10 to +45 -10 to +45 -10 to +45 -10 to +45Range, Operating, °C -55 to +90 -55 to +90 -55 to +90 -55 to +90Effect on Sensitivity, % Rdg/100°C +/-.15 +/-.15 +/-.15 +/-.15Effect on Zero, % R.O./100°C +/-.30 +/-.30 +/-.30 +/-.30

Rated Output, mV/V, Nominal 2.0 2.0 2.0 2.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Electrical

Temperature

Accuracy

HIGH CAPACITY FATIGUE RATED METRIC (FR - M) SERIES FORCE TRANSDUCERS

FEATURESFirst Choice for Fatigue Testing ApplicationsGuaranteed for 100 Million Fully Reversed CyclesLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsBarometric Pressure Compensation

Page 33: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (kN)Review Drawing(in mm)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 28

FR40M FR42M FR60M FR60M

500 600 1100 1350

1. Height Total 167.6 180.3 243.1 243.1 2. Max. Clearance Radius 156.4 156.4 219.7 219.7 3. Cell and Base Diameter 279.4 279.4 406.4 406.4 4. Cell Height to Hub 88.9 101.6 133.3 133.3 5. Cell Body Height 76.2 88.9 120.6 120.6 6. Hub Diameter 122.2 122.2 200.4 200.4 7. Mounting B.C. Diameter 228.6 228.6 331.6 331.6 8. Symmetric B.C. Offset 11.25 degrees 11.25 degrees 9 degrees 9 degrees 9. Mounting Hole Diameter 19.8 19.8 30.0 30.0 10. Hub Thread M72 x 2, 81.3 Dp. M72 x 2, 94.0 Dp. M100 x 3, 120.6 Dp. M100 x 3, 120.6 Dp. 11. Bolt Head Protrusion 15.2 15.2 20.8 20.8 12. Base Thickness 76.2 76.2 101.6 101.6 13. Base Step Height .8 .8 .8 .8 14. Base Step Diameter 122.7 122.7 200.4 200.4 15. Base Thread M72 x 2, 68.6 Dp. M72 x 2, 68.6 Dp. M100 x 3, 92.7 Dp. M100 x 3, 92.7 Dp.

Page 34: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (kN)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 29

SWP10M SWP10M SWP20M SWP30M

1.5, 2.5 5, 10 25, 50 100, 250 500

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight, kg (lbs.) .45 (1.0) 1.30 (2.9) 4.13 (9.1) 10.66 (23.5)Weight w/base, kg (lbs.) 1.13 (2.5) 2.95 (6.5) 9.75 (21.5) 23.81 (52.5)Flexure Material Aluminum Steel Steel Steel

Mechanical

Static Error Band, % R.O. +/-.02 +/-.03 +/-.04 +/-.04Nonlinearity, % R.O. +/-.03 +/-.04 +/-.04 +/-.04Hysteresis, % R.O. +/-.02 +/-.04 +/-.04 +/.04Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.10 +/-.10 +/-.10 +/-.10Side Load Sensitivity, % +/-.10 +/-.10 +/-.10 +/-.10Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °C -10 to +45 -10 to +45 -10 to +45 -10 to +45Range, Operating, °C -55 to +90 -55 to +90 -55 to +90 -55 to +90Effect on Sensitivity, % Rdg/100°C +/-.15 +/-.15 +/-.15 +/-.15Effect on Zero, % R.O./100°C +/-.27 +/-.27 +/-.27 +/-.27

Rated Output, mV/V, Nominal 2.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Electrical

Temperature

Accuracy

SHEAR WEB PRECISION METRIC (SWP - M) SERIES FORCE TRANSDUCERS

High Accuracy Version of SW-M SeriesLow HeightGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsTemperature CompensatedBarometric Pressure CompensationOutput to 4mV/V

FEATURES

Page 35: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (kN)Review Drawing(in mm)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 30

SWP10M SWP10M SWP20M SWP30M

1. Height Total 65.0 65.0 93.2 118.1 2. Max. Clearance Radius 64.3 64.3 88.9 114.3 3. Cell and Base Diameter 104.8 104.8 154.0 203.2 4. Cell Height to Hub 34.9 34.9 44.5 63.5 5. Cell Body Height 31.8 31.8 41.4 57.2 6. Hub Diameter 32.8 32.8 65.5 95.5 7. Mounting B.C. Diameter 88.9 88.9 130.3 130.3 8. Symmetric B.C. Offset 22.5 degrees 22.5 degrees 15.0 degrees 11.25 degrees 9. Mounting Hole Diameter 7.1 7.1 10.4 13.5 10. Hub Thread M12 x 1.25, 28.5 Dp. M16 x 2, 28.5 Dp. M33 x 2, 38.1 Dp. M42 x 2, 55.9 Dp. 11. Bolt Head Protrusion 4.5 4.5 7.3 10.1 12. Base Thickness 28.7 28.7 44.5 50.8 13. Base Step Height .8 .8 .8 .8 14. Base Step Diameter 31.8 31.8 57.2 76.2 15. Base Thread M12 x 1.25, 22.4 Dp. M16 x 2, 22.4 Dp. M33 x 2, 38.1 Dp. M42 x 2, 44.5 Dp.

1.5, 2.5 5, 10 25, 50 100, 250 500

Page 36: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (kN)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

FEATURESHigh Accuracy at High CapacityLow HeightLow Guaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsBarometric Pressure CompensationTemperature Output 4mV/V

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 31

SWP40M SWP42M SWP60M SWP60M

1000 1200 2200 2700

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (kg) 34 38 111 111Weight w/base (kg) 66 71 203 203Flexure Material Steel Steel Steel Steel

Mechanical

Static Error Band, % R.O. +/-.05 +/-.06 +/-.10 +/-.10Hysteresis, % R.O. +/-.05 +/-.06 +/-.10 +/-.10Nonlinearity, % R.O. +/-.05 +/-.06 +/-.10 +/.10Nonrepeatability, % R.O. +/-.005 +/-.005 +/-.01 +/-.01Creep, % in 20 minutes +/-.01 +/-.015 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.1 +/-.1 +/-.2 +/-.2Side Load Sensitivity, % +/-.1 +/-.1 +/-.2 +/-.2Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °C -10 to +45 -10 to +45 -10 to +45 -10 to +45Range, Operating, °C -55 to +90 -55 to +90 -55 to +90 -55 to +90Effect on Sensitivity, % Rdg/100°C +/-.15 +/-.15 +/-.15 +/-.15Effect on Zero, % R.O./100°C +/-.15 +/-.15 +/-.15 +/-.15

Rated Output, mV/V, Nominal 4.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Electrical

Temperature

Accuracy

HIGH CAPACITY SHEAR WEB PRECISION METRIC (SWP - M) SERIES FORCE TRANSDUCERS

Page 37: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (kN)Review Drawing(in mm)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 32

SWP40M SWP42M SWP60M SWP60M

1000 1200 2200 2700

1. Height Total 167.6 180.3 243.1 243.1 2. Max. Clearance Radius 156.5 156.5 219.7 219.7 3. Cell and Base Diameter 279.4 279.4 406.4 406.4 4. Cell Height to Hub 88.9 101.6 133.3 133.3 5. Cell Body Height 76.2 88.9 120.6 120.6 6. Hub Diameter 122.2 122.2 200.4 200.4 7. Mounting B.C. Diameter 228.6 228.6 331.6 331.6 8. Symmetric B.C. Offset 11.25 degrees 11.25 degrees 9 degrees 9 degrees 9. Mounting Hole Diameter 19.8 19.8 30.0 30.0 10. Hub Thread M72 x 2, 81.3 Dp. M72 x 2, 94.0 Dp. M100 x 3, 120.6 Dp. M100 x 3, 120.6 Dp. 11. Bolt Head Protrusion 15.2 15.2 20.8 20.8 12. Base Thickness 76.2 76.2 101.6 101.6 13. Base Step Height .8 .8 .8 .8 14. Base Step Diameter 122.7 122.7 200.4 200.4 15. Base Thread M72 x 2, 68.6 Dp. M72 x 2, 68.6 Dp. M100 x 3, 92.7 Dp. M100 x 3, 92.7 Dp.

Page 38: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (kN)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 33

CS10M CS10M CS20M CS30M

Designed for Metrology Lab UseMeets ASTM E74 Requirements Class AA to 10% of Range (Most Models) Class A to 2% of RangeLowest CreepLowest Sensitivity to Rotation ErrorLowest Sensitivity to Reproducibility ErrorsAll Features Meet or Exceed SWP-M Series

FEATURES

Lower Load Limit % of R.O. 2.0 2.0 2.0 2.0Static Error Band, % R.O. +/-.02 +/-.03 +/-.03 +/-.03Nonlinearity, % R.O. +/-.02 +/-.03 +/-.03 +/-.03Hysteresis, % R.O. +/-.02 +/-.04 +/-.04 +/.04Nonrepeatability, % R.O. +/-.005 +/-.005 +/-.005 +/-.005Creep, % in 20 minutes +/-.01 +/-.01 +/-.01 +/-.01Off-Center Load Sensitivity, %/inch +/-.05 +/-.05 +/-.05 +/-.05Side Load Sensitivity, % +/-.05 +/-.05 +/-.05 +/-.05Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °C -10 to +45 -10 to +45 -10 to +45 -10 to +45Range, Operating, °C -55 to +90 -55 to +90 -55 to +90 -55 to +90Effect on Sensitivity, % Rdg/100°C +/-.15 +/-.15 +/-.15 +/-.15Effect on Zero, % R.O./100°C +/-.15 +/-15 +/-.15 +/-.15

Rated Output, mV/V, Nominal 2.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight, kg (lbs.) 1.32 (2.9) 3.13 (6.9) 10.80 (23.8) 26.17 (57.7)Flexure Material Steel Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

CALIBRATION STANDARD METRIC (CS - M) SERIES FORCE TRANSDUCERS

1.5, 2.5 5, 10 25, 50 100, 250 500

Page 39: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (kN)Review Drawing(in mm)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 34

CS10M CS10M CS20M CS30M

1. Height Total 106.4 106.4 163.6 200.2 2. Max. Clearance Radius 64.3 64.3 88.9 114.3 3. Cell and Base Diameter 104.8 104.8 154.0 203.2 4. Cell and Base Height (to Hub) 63.6 63.6 89.0 114.3 5. Bolt Head Protrusion 5.1 5.1 7.6 10.2 6. Base Step Height .8 .8 .8 .8 7. Base Step Diameter 31.8 31.8 57.2 76.2 8. Base Thread M12 x 1.25, 22.4 Dp. M16 x 2, 22.4 Dp. M33 x 2, 38.1 Dp. M42 x 2, 44.5 Dp. 9. Adapter Thread M12 x 1.25 M16 x 2 M33 x 2 M42 x 2 10. Adapter Thread Depth 19.0 19.0 38.1 44.4 11. Adapter End Radius 152 152 152 305 12. Connector MS3112_E10 MS3112_E10 MS3112_E10 MS3112_E10 w/protector

1.5, 2.5 5, 10 25, 50 100, 250 500

Page 40: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (kN)

SPECIFICATIONS

SHEAR WEB LOAD CELLS

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Page 35

CS40M CS42M CS60M CS60M

1000 1200 2200 2700

Mechanical

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (kg) 75 80 235 235Flexure Material Aluminum Steel Steel Steel

FEATURESDesigned for Metrology Lab UseMeets ASTM E74 Requirements Class A to 4% of RangeGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Sensitivity to Rotation ErrorLow Sensitivity to Reproducibility ErrorsLow Susceptibility to Magnetic Fields

Lower Load Limit % of R.O. 4.0 4.0 4.0 4.0Static Error Band, % R.O. +/-.05 +/-.06 +/-.10 +/-.10Hysteresis, % R.O. +/-.05 +/-.06 +/-.10 +/-.10Nonlinearity, % R.O. +/-.05 +/-.06 +/-.10 +/.10Nonrepeatability, % R.O. +/-.005 +/-.005 +/-.01 +/-.01Creep, % in 20 minutes +/-.01 +/-.015 +/-.025 +/-.025Off-Center Load Sensitivity, %/inch +/-.1 +/-.1 +/-.2 +/-.2Side Load Sensitivity, % +/-.1 +/-.1 +/-.2 +/-.2Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °C -10 to +45 -10 to +45 -10 to +45 -10 to +45Range, Operating, °C -55 to +90 -55 to +90 -55 to +90 -55 to +90Effect on Sensitivity, % Rdg/100°C +/-.15 +/-.15 +/-.15 +/-.15Effect on Zero, % R.O./100°C +/-.30 +/-.30 +/-.30 +/-.30

Rated Output, mV/V, Nominal 4.0 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Electrical

Temperature

Accuracy

HIGH CAPACITY CALIBRATION STANDARD METRIC (CS - M) SERIES FORCE TRANSDUCERS

Page 41: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SHEAR WEB LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (kN)Review Drawing(in mm

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 36

CS40M CS42M CS60M CS60M

1000 1200 2200 2700

1. Height Total 294.1 306.8 422.4 422.4 2. Max. Clearance Radius 156.5 156.5 219.7 219.7 3. Cell and Base Diameter 279.4 279.4 406.4 406.4 4. Cell and Base Height (to Hub) 165.1 177.8 234.9 234.9 5. Bolt Head Protrusion 15.2 15.2 20.8 20.8 6. Base Step Height .8 .8 .8 .8 7. Base Step Diameter 122.7 122.7 200.4 200.4 8. Base Thread M72 x 2, 68.6 Dp. M72 x 2, 68.6 Dp. M100 x 3, 92.7 Dp. M100 x 3, 92.7 Dp. 9. Adapter Thread M72 x 2 M72 x 2 M100 x 3 M100 x 3 10. Adapter Thread Depth 63.5 63.5 88.9 88.9 11. Adapter End Radius 304.8 304.8 508.0 508.0 12. Connector MS3112_E10 MS3112_E10 MS3112_E10 MS3112_E10 w/protector w/protector w/protector w/protector

Page 42: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

5000 SERIES HIGH CAPACITYUNIVERSAL COLUMN FORCE TRANSDUCERS

FEATURES

Static Error Band, % R.O. +/-.2 +/-.2 +/-.2 +/-.2Hysteresis, % R.O. +/-.2 +/-.2 +/-.2 +/-.2Nonlinearity, % R.O. +/-.2 +/-.2 +/-.2 +/.2Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -30 to +200 -30 to +200 -30 to +200 -30 to +200Effect on Sensitivity, % Rdg/100°F +/-.3 +/-.3 +/-.3 +/-.3Effect on Zero, % R.O./100°F +/-.3 +/-.3 +/-.3 +/-.3

Rated Output, mV/V, Nominal 2.0 2.0 2.0 2.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (lbs.) 14 52 146, 153 329Flexure Material Steel Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

Universal Tension and Compression.2% AccuracyCapacities to 1 Million lbf.Bayonet Connector

Page 37

MODEL

CAPACITY (lbf) 5030 5040 5060 5080

100K 250K, 300K 500K, 600K 1000K

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

SPECIFICATIONS

COLUMN LOAD CELLS

Page 43: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

COLUMN LOAD CELLS

THE ENGINEER'S CHOICE FOR FORCE MEASUREMENT PRODUCTS

DIMENSIONS

OPTIONS

Dual bridge configurationOutput adjustment to standardIntegral cableCustom connectorsReduced temperature errors

Loading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

1. Height Total 10.00 13.00 23.00 27.50 2. Max. Clearance Radius 2.26 3.53 4.27 5.50 3. End Diameter 3.00 5.00 6.50 9.00 4. Total Diameter 3.38 5.50 7.00 9.50 5. End Thread 2-12, 2.00 Dp. 3 - 12, 3.00 Dp. 4 - 8, 4.50/5.00 Dp. 6 - 8, 6.00 Dp.

Review Drawing(in inches)

Page 38

MODEL

CAPACITY (lbf) 5030 5040 5060 5080

100K 250K, 300K 500K, 600K 1000K

Page 44: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

SPECIFICATIONS

5100 SERIES HIGH CAPACITYCOMPRESSION COLUMN FORCE TRANSDUCERS

COLUMN LOAD CELLS

Compact Design.2% AccuracySpecial Capacities to 2 Million lbf.Bayonet Connector

FEATURES

Static Error Band, % R.O. +/-.2 +/-.2 +/-.2 +/-.2Hysteresis, % R.O. +/-.2 +/-.2 +/-.2 +/-.2Nonlinearity, % R.O. +/-.2 +/-.2 +/-.2 +/.2Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -30 to +200 -30 to +200 -30 to +200 -30 to +200Effect on Sensitivity, % Rdg/100°F +/-.3 +/-.3 +/-.3 +/-.3Effect on Zero, % R.O./100°F +/-.3 +/-.3 +/-.3 +/-.3

Rated Output, mV/V, Nominal 2.0 2.0 2.0 2.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Mechanical

Electrical

Temperature

Accuracy

Page 39

MODEL

CAPACITY (lbf) 5130 5140 5160 5180

100K 250K, 300K 500K, 600K 1000K

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Safe Overload Range, % R.O. +/-150 +/-150 +/-150 +/-150Weight (lbs.) 5 25 45, 46 96Flexure Material Steel Steel Steel Steel

Page 45: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

COLUMN LOAD CELLS

THE ENGINEER'S CHOICE FOR FORCE MEASUREMENT PRODUCTS

DIMENSIONS

1. Height Total 5.00 9.00 10.00 12.00 2. Max. Clearance Radius 1.86 2.78 3.29 4.02 3. End Diameter 2.00 3.50 4.50 6.00 4. Total Diameter 2.38 3.95 5.00 6.50 5. Base Step Height .03 .03 .03 .03 6. Base Step Diameter 1.68 2.94 3.89 5.02 7. End Thread 3/8 -24, .50 Dp. 1/2 - 20, .75 Dp. 1 - 14, .75 Dp. 1 - 14, 1.00 Dp. 8. Load Button Spherical Radius 12 15 20 20

Review Drawing(in inches)

OPTIONS

Dual bridge configurationOutput adjustment to standardIntegral cableCustom connectorsReduced temperature errors

Loading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

Page 40

MODEL

CAPACITY (lbf) 5130 5140 5160 5180

100K 250K, 300K 500K, 600K 1000K

Page 46: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

5200 SERIES UNIVERSAL HIGH CAPACITY LOAD CELLS

FEATURES

Static Error Band, % R.O. +/-.10 +/-.10 +/-.10Hysteresis, % R.O. +/-.10 +/-.10 +/-.10Nonlinearity, % R.O. +/-.10 +/-.10 +/-.10Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 Range, Operating, °F -30 to +200 -30 to +200 -30 to +200 Effect on Sensitivity, % Rdg/100°F +/-.08 +/-..08 +/-..08Effect on Zero, % R.O./100°F +/-.15 +/-.15 +/-.15

Rated Output, mV/V, Nominal 2.0 2.0 2.0Excitation Voltage, VDC 10 10 10Input Resistance, Ohms 350 350 350Output Resistance, Ohms 350 350 350Insulation Resistance, Megohm 5000 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150 +/-150Weight (lbs.) 34 42Flexure Material Steel Steel Steel

Mechanical

Electrical

Temperature

Accuracy

Universal Tension and Compression4 Column Cell.1% AccuracyAccomodates High Side and Off-Center LoadsBayonet Connector

MODEL

CAPACITY (lbf) 5230 5240 5260

100K, 135K 250K 500K

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

COLUMN LOAD CELLS

SPECIFICATIONS

Page 41

Page 47: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

COLUMN LOAD CELLS

THE ENGINEER'S CHOICE FOR FORCE MEASUREMENT PRODUCTS

1. Height Total 8.00 8.00 Consult 2. Max. Clearance Radius 3.23 3.48 Factory 3. End Diameter 5.00 5.50 4. Total Diameter 5.49 5.99 5. End Thread 2-12, 2.4 Dp. (2.7 135k) 2 - 12, 2.75 Dp. 6. Hub Diameter 3.30 4.00

Review Drawing(in inches)

4

1

2

5

6

3

MODEL

CAPACITY (lbf) 5230 5240 5260

100K, 135K 250K 500K

DIMENSIONS

Page 42

OPTIONS

Dual bridge configurationOutput adjustment to standardIntegral cableCustom connectorsReduced temperature errors

Loading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

Page 48: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

HEAVY DUTY (XHD) SERIES FATIGUE RATED UNIVERSAL LOAD CELLS

FEATURES

Static Error Band, % R.O. +/-.05 +/-.05 +/-.08 +/-.08Hysteresis, % R.O. +/-.05 +/-.05 +/-.08 +/-.08Nonlinearity, % R.O. +/-.05 +/-.05 +/-..08 +/-.08Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025 +/-.025Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115 +15 to +115 Range, Operating, °F -30 to +200 -30 to +200 -30 to +200 -30 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.15 +/-.15 +/-.15 +/-.15

Rated Output, mV/V, Nominal 2.0 2.0 2.0 2.0Excitation Voltage, VDC 10 10 10 10Input Resistance, Ohms 350 350 350 350Output Resistance, Ohms 350 350 350 350Insulation Resistance, Megohm 5000 5000 5000 5000

Safe Overload Range, % R.O. +/-200 +/-200 +/-200 +/-200Weight (lbs.) 26 47 ---- ----Flexure Material Stainless Steel Stainless Steel Stainless Steel Stainless Steel

Mechanical

Electrical

Temperature

Accuracy

High Capacity Measurement in a Compact SizeFatigue Rated--Guaranteed for 100 Million Fully Reversed Load CyclesHigh Accuracy to .05%.Stainless Steel

MODEL

CAPACITY (lbf) XHD20 XHD30 XHD40 XHD60

55K 110K 220K 550K

TOVEY ENGINEERING www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

COLUMN LOAD CELLS

SPECIFICATIONS

Page 43

Page 49: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

COLUMN LOAD CELLS

THE ENGINEER'S CHOICE FOR FORCE MEASUREMENT PRODUCTS

1. Height Total 8.00 8.00 Consult 2. Max. Clearance Radius 3.10 3.86 Factory 3. End Diameter 4.00 5.50 4. Total Diameter 4.50 6.00 5. End Thread 1 1/2 - 12, 2 Dp. 2 - 12, 2 Dp. 6. Hub Diameter 2.38 3.25

Review Drawing(in inches)

MODEL

CAPACITY (lbf) XHD20 XHD30 XHD40 & 60

55K 110K 220K, 550K

DIMENSIONS

Page 44

OPTIONS

Dual bridge configurationOutput adjustment to standardIntegral cableCustom connectorsReduced temperature errors

Loading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

Page 50: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

50, 100, 250 500, 1K, 2K 3K, 5K

SPECIFICATIONS

TOVEY ENGINEERING

COMPACT LOAD CELLS

AccuracyZero Balance, % R.O. +/- 1.0 +/- 1.0Non linearity, % R.O. +/- 0.03 +/- 0.03Hysteresis, % R.O. +/- 0.03 +/- 0.03Non-Repeatability, % R.O. +/- 0.01 +/- 0.01Static Error Band, % R.O. +/- 0.03 +/- 0.03Creep, % Reading in 20 Minutes +/- 0.03 +/- 0.03

TemperatureRange, Compensated, °F +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100 °F 0.08 0.08Effect on Zero, %R.O./100 °F 0.15 0.15

ElectricalExcitation Voltage, Recommended, Vdc 10 10Input resistance, Ohms 350 +40/-3.5 350 +40/-3.5Output Resistance, Ohms 350 +/- 3.5 350 +/- 3.5Sensitivity (Rated Output), mV/V, Nominal 3 3Insulation Resist., Bridge/Case, Meg Ohm 5000 (@ 50 VDC) 5000 (@ 50 VDC)

MechanicalSafe Overload Range, % R.O. 150 150Flexure Material Aluminum Stainless Steel

CAPACITY (lbf)

TOVEY ENGINEERINGPhoenix, Arizona

SSC-1K-0001

CL

BAYONETCONNECTOR

1

2

3

4

LOADING HOLE2 PLACES

5

CL

CL

BayonetConnector

DIMENSIONS

Loading Hole2 Places

FEATURESPremium Version of the Standard "S" CellDesigned for the Test Measurements MarketIn-Line LoadingSealed for Environmental ProtectionIntegral Connector or Cable

Dual bridgeOutput adjustment to standardSpecial connectorIntegral cable

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIESOPTIONS

Page 45

www.toveyengineering.com e-mail: [email protected] N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

PREMIUM “S” TYPE (SSC) SERIES LOAD CELLS

lbf 1 2 3 4 5

50 2.00 .48 .80 2.50 1/4 - 28 UNF-2B 100 2.00 .48 .80 2.50 1/4 - 28 UNF-2B 250 2.00 .48 .80 2.50 1/4 - 28 UNF-2B 500 2.00 .97 1.42 3.00 1/2 - 20 UNF-2B 1K 2.00 .97 1.42 3.00 1/2 - 20 UNF-2B 2K 2.00 .97 1.42 2.97 1/2 - 20 UNF-2B 3K 2.00 .97 1.42 2.97 1/2 - 20 UNF-2B 5K 2.50 1.47 1.92 3.47 5/8 - 18 UNF-2B

Capacity

Page 51: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

50, 100, 250500, 1K, 2K

3K, 5K

RSC RSC

SPECIFICATIONS

COMPACT LOAD CELLS

CAPACITY (lbf)

DIMENSIONS

AccuracyZero Balance, % R.O. +/- 1.0 +/- 1.0Non linearity, % R.O. +/- 0.03 +/- 0.03Hysteresis, % R.O. +/- 0.03 +/- 0.03Non-Repeatability, % R.O. +/- 0.01 +/- 0.01Static Error Band, % R.O. +/- 0.03 +/- 0.03Creep, % Reading in 20 Minutes +/- 0.03 +/- 0.03

TemperatureRange, Compensated, °F +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100 °F 0.08 0.08Effect on Zero, %R.O./100 °F 0.15 0.15

ElectricalExcitation Voltage, Recommended, Vdc 10 10Input resistance, Ohms 350 +40/-3.5 350 +40/-3.5Output Resistance, Ohms 350 +/- 3.5 350 +/- 3.5Sensitivity (Rated Output), mV/V, Nominal 2 2Insulation Resist., Bridge/Case, Meg Ohm 5000 (@ 50 VDC) 5000 (@ 50 VDC)

MechanicalSafe Overload Range, % R.O. 300 300Flexure Material Aluminum Stainless SteelFatigue Rated Yes Yes

EY ENGINEERINGPhoenix, Arizona

RSC-1K-0001

CL

NETOR

1

2

3

4

LOADING HOLE2 PLACES

5

CL

CL

5 2

31

4

Loading Hole2 Places

BayonetConnector

FEATURESDesigned for the Test Measurements MarketRugged Design "S" CellFatigue RatedHigh Resistance to Misaligned LoadsSealed for Environmental ProtectionIntegral Connector or Cable

Dual bridgeOutput adjustment to standardSpecial connectorIntegral cable

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

OPTIONS

Page 46

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

FATIGUE RATED “S” TYPE (RSC SERIES) LOAD CELLS

lbf 1 2 3 4 5

100 2.00 .97 .97 2.50 3/8 - 24 UNF-2B 250 2.00 .97 .97 2.50 3/8 - 24 UNF-2B 500 2.25 1.25 1.58 2.50 1/2 - 20 UNF-2B 1K 2.25 1.25 1.58 2.50 1/2 - 20 UNF-2B

Capacity

Page 52: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

SPECIFICATIONS

SCT SERIES PRECISION OVERLOAD PROTECTEDS-TYPE LOAD CELLS

COMPACT LOAD CELLS

FEATURES

Static Error Band, % R.O. +/-.02Nonlinearity, % R.O. +/-.02Hysteresis, % R.O. +/-.02Nonrepeatability, % R.O. +/-.01Creep, % in 20 minutes +/-.025Zero Balance, % R.O. +/-1.0

Range, Compensated, °F 0 to +125 Range, Operating, °F -10 to +175 Effect on Sensitivity, % Rdg/100°F +/-.08Effect on Zero, % R.O./100°F +/-.15

Range, Compensated, °C -15 to +50 Range, Operating, °C -25 to +80 Effect on Sensitivity, % Rdg/100°C +/-.15Effect on Zero, % R.O./100°C +/-.27

Rated Output, mV/V, Nominal 2.0Excitation Voltage, VDC 10Input Resistance, Ohms 350Output Resistance, Ohms 350Insulation Resistance, Megohm 5000

Safe Overload Range, % R.O. +/-1000Flexure Material Aluminum

Mechanical

Electrical

Temperature

Accuracy

Overload Protected to 1000% of FS in both Tension and CompressionHigh Accuracy--.02% of R.O.Integral Cable

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

SCT

DIMENSIONS

1. Width 2.00 50.8 2.00 50.82. Flexure Thickness .50 12.7 1.00 25.43. Total Thickness .85 21.6 1.35 34.34. Height 2.50 63.5 2.50 63.55. Load Thread 1/4 - 28 M6 X 1 1/2 - 20 M12X1.75

SCT US (lbf) Metric (N) US (lbf) Metric (N)2.2, 4.4 10, 20, 50 110 500

11, 22, 55 100, 250 (inches) (mm) (inches) (mm)

Review Drawing

10 - 500 N2.2 - 110 lbf

Page 47

Page 53: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

SPECIFICATIONS

ZXT SERIES HIGH ACCURACYS-TYPE LOAD CELLS

COMPACT LOAD CELLS

FEATURES

Static Error Band, % R.O. +/-.03Nonlinearity, % R.O. +/-.03Hysteresis, % R.O. +/-.03Nonrepeatability, % R.O. +/-.01Creep, % in 20 minutes +/-.03Zero Balance, % R.O. +/-1.0

Range, Compensated, °F 15 to +105 Range, Operating, °F -30 to +150 Effect on Sensitivity, % Rdg/100°F +/-.08Effect on Zero, % R.O./100°F +/-.15

Range, Compensated, °C -10 to +40 Range, Operating, °C -35 to +65 Effect on Sensitivity, % Rdg/100°C +/-.15Effect on Zero, % R.O./100°C +/-.17

Rated Output, mV/V, Nominal 3.0Excitation Voltage, VDC, Recommended 5 - 12 Input Resistance, Ohms 430 +/-60 Output Resistance, Ohms 350 +/-3.5 Insulation Resistance, Megohm 5000 (50 VDC)

Safe Overload Range, % R.O. +/-150Flexure Material Steel

Mechanical

Electrical

Temperature

Accuracy

Accuracy--.03%Tension and CompressionIntegral Cable

ZXT

50 - 20K lbf500N - 50kN

1

25

4

3

4 wire shielded PU cable (5mm diameter)

ZXT Review Drawing

50, 100, 200 lbf 2.00 .50 .63 2.50 1/4 - 28 UNF500 N, 1 kN 50.8 12.7 16.1 63.5 M8

500, 1K lbf 2.00 .75 .88 2.50 1/2 - 20 UNF2.5, 5 kN 50.8 19.1 22.4 63.5 M12

` 2K lbf 2.00 1.00 1.13 2.50 1/2 - 20 UNF 10kN 50.8 25.4 28.8 63.5 M12

25kN 76.2 25.4 28.8 101.6 M20 x 1.5

5K, 10K lbf 3.00 1.00 1.13 4.00 3/4 - 16 UNF 50kN 76.2 25.4 28.8 101.6 M20 x 1.5

20K lbf 5.00 2.00 2.13 7.00 1 1/4 - 12 UNF

1 2 3 4 5 (in inches

(mm)

Capacity

Dimension

DIMENSIONS

Page 48

CL

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 54: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

SPECIFICATIONS

SLH SERIES LOW HEIGHTS-TYPE LOAD CELLS

COMPACT LOAD CELLS

FEATURES

Static Error Band, % R.O.Nonlinearity, % R.O. Hysteresis, % R.O.Nonrepeatability, % R.O. +/-.03Creep, % in 20 minutes +/-.05Zero Balance, % R.O. +/-1.0

Range, Compensated, °F 0 to +150 Range, Operating, °F -65 to +200 Effect on Sensitivity, % Rdg/100°F +/-.08Effect on Zero, % R.O./100°F +/-.50

Range, Compensated, °C -15 to +65 Range, Operating, °C -55 to +90 Effect on Sensitivity, % Rdg/100°C +/-.15Effect on Zero, % R.O./100°C +/-.75

Rated Output, mV/V, Nominal 2.0Excitation Voltage, VDC 10Input Resistance, Ohms 350Output Resistance, Ohms 350Insulation Resistance, Megohm 5000

Safe Overload Range, % R.O. +/-150Flexure Material Aluminum

Mechanical

Electrical

Temperature

Accuracy

Compact Size Tension and CompressionAccuracy--.05%-.10% of R.O.Integral Cable

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

SLH

5 - 1K lbf25N - 4.5kN

1

2

3 4

5

6

7

DIMENSIONS

1. Height .73 18.6 .73 18.6 .98 24.92. Width 1.80 45.7 2.00 50.8 2.12 53.83. Total Thickness .52 13.2 .64 16.4 .90 22.94. Flexure Thickness .34 8.6 .46 11.8 .72 18.35. Hub Location .90 22.9 1.00 25.4 1.06 26.9 6. Hub Width .50 12.7 .50 12.7 .57 14.5 7. Hub Thread 10 - 32, .20 Dp. 1/4 - 28, .25 Dp. 3/8 24, .38 Dp.

SLH US (lbf) Metric (N) US (lbf) Metric (N) US (lbf) Metric (N)

25, 50 115, 225 200, 300 900, 1.35k 5, 10 25, 50 100 450 500, 1K 2.25k, 4.5k (inches) (mm) (inches) (mm) (inches) (mm)

Review Drawing+/-.05 +/-.10+/-.05 +/-.10+/-.05 +/-.10

<=300 lbf >300lbf

Page 49

Page 55: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)50, 100, 300

FR5

LOW CAPACITY FATIGUE RATED (FR5) SERIES LOAD CELLS

FEATURESFatigue RatedSmall ScaleSealedStatic Error Band .05%In-line Loading Holes

Additional bridgesOutput adjustment to standard valueCompression overload protectionIntegral cableCustom connectors

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

AccuracyStatic Error Band, % R.O. +/- 0.05Non linearity, % R.O. +/- 0.05Hysteresis, % R.O. +/- 0.05Non-Repeatability, % R.O. +/- 0.01Creep, % Reading in 20 Minutes +/- 0.05Zero Balance, % R.O. +/- 1.0

TemperatureRange, Compensated, °F +15 to +115Range, Operating, °F -65 to +200Effect on Sensitivity, % Rdg/100 °F 0.20Effect on Zero, %R.O./100 °F 0.15

ElectricalExcitation Voltage, Recommended, Vdc 10Input resistance, Ohms 700 +80/-7Output Resistance, Ohms 700 +80/-7Sensitivity (Rated Output), mV/V, Nominal 2Insulation Resist., Bridge/Case, Meg Ohm 5000 (@ 50 VDC)

MechanicalSafe Overload Range, % R.O. 150Weight (lbs.) .8Flexure Material Aluminum

1/4 - 28 UNF, .28 DP, 2PLFor Metric Version: m6 X 1.0, 7.1DP, 2PL

Alternate Connector Location

Page 50

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

SPECIFICATIONS

COMPACT LOAD CELLS

DIMENSIONS

OPTIONS

ACCESSORIES

Page 56: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

500, 1000 2.5K, 5K, 7.5K

2029 2030

LOW HEIGHT COLUMN (2029/2030 SERIES) FORCE TRANSDUCERS

CAPACITY (lbf)

FEATURESSealed for Environmental ProtectionWater Emersion to 300 ft.Integral CableExternal Male Threads

Loading fixturesShunt calibration resistorInstrumentation

Consult factory for dimensions.

Dual bridgeOutput adjustment to standard valueFemale thread (one or both ends)

AccuracyStatic Error Band, % R.O. +/- 0.25 +/- 0.25Non linearity, % R.O. +/- 0.25 +/- 0.25Hysteresis, % R.O. +/- 0.15 +/- 0.15Non-Repeatability, % R.O. +/- 0.05 +/- 0.05Creep, % Reading in 20 Minutes +/- 0.03 +/- 0.03Zero Balance, % R.O. +/- 1.0 +/- 1.0

TemperatureRange, Compensated, °F +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100 °F 0.15 0.15Effect on Zero, %R.O./100 °F 0.15 0.15

ElectricalExcitation Voltage, Recommended, Vdc 10 10Input resistance, Ohms 1000 +100/-10 1000 +100/-10Output Resistance, Ohms 1000 +100/-10 1000 +100/-10Sensitivity (Rated Output), mV/V, Nominal 3 3Insulation Resist., Bridge/Case, Meg Ohm 5000 (@ 50 VDC) 5000 (@ 50 VDC)

MechanicalSafe Overload Range, % R.O. 150 150Flexure Material Aluminum Stainless Steel

Page 51

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

COMPACT LOAD CELLS

SPECIFICATIONS

OPTIONS

ACCESSORIES

Page 57: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

SPECIFICATIONS

LW SERIES LOAD WASHERS

COMPACT LOAD CELLS

FEATURES

Static Error Band, % R.O. +/-.5

Range, Compensated, °F 60 to +160 Range, Operating, °F -65 to +250 Effect on Zero, % R.O./100°F +/-.50

Range, Compensated, °C 16 to +71 Range, Operating, °C -54 to +121 Effect on Zero, % R.O./100°C +/-.75

Rated Output, mV/V, Nominal 2.0Excitation Voltage, VDC 10Input Resistance, Ohms 350Output Resistance, Ohms 350

Safe Overload Range, % R.O. +/-150Flexure Material Steel

Mechanical

Electrical

Temperature

Accuracy

Compact Size (.5 to 1.12” Dia.)Hollow Cylinder Integral CableSpecial Sizes and Capacities AvailableOptional Stainless Steel

MODEL LW

2K - 10K lbf

DIMENSIONS

O/D .50 .53 .65 .89 1.12 I/D (Screw Size) #8 #10 1/4 3/8 1/2Total Height .30 .30 .30 .30 .30

MODEL LW

2K 3K 5K 7.5K 10K Review Drawing

Page 52

CAPACITY (lbf)

(in inches)

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 58: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

STAINLESS STEEL LOAD CELLS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

SWS10 SWS20 SWS30

STAINLESS STEEL (SWS SERIES)FORCE TRANSDUCERS

FEATURESStainless Steel ConstructionWelded DiaphragmOptional Hermetically Sealed ConnectorGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepLow Susceptibility to Magnetic FieldsTemp. and Barometric Pressure Compensation

Static Error Band, % R.O. +/-.05 +/-.05 +/-.06Nonlinearity, % R.O. +/-.05 +/-.05 +/-.05Hysteresis, % R.O. +/-.06 +/-.06 +/-.06Nonrepeatability, % R.O. +/-.01 +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025 +/-.025Off-Center Load Sensitivity, % /inch +/-.25 +/-.25 +/-.25Side Load Sensitivity, % /inch +/-.25 +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100 °F +/-.08 +/-.08 +/-.08Effect on Zero, % R.O./100 °F +/-.15 +/-.15 +/-.15

Rated Output, mV/V, Nominal 4.0 4.0 4.0Excitation Voltage, VDC 10 10 10Input Resistance, Ohms 350 +40/-3.5 350 +40/-3.5 350 +40/-3.5 Output Resistance, Ohms 350 +/-3.5 350+/-3.5 350+/-3.5Insulation Resistance, Megohm 5000 @ 50 VDC 5000 @ 50 VDC 5000 @ 50VDC

Safe Overload Range, % R.O. +/-150 +/-150 +/-150Flexure Material Stainless Steel Stainless Steel Stainless Steel

Mechanical

Electrical

Temperature

Accuracy

Page 53

5K, 10K 25K,50K 100K

Note: Shown with Optional Integral Cable.

Page 59: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

STAINLESS STEEL LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionHermetically sealed connectorConnector protectionIntegral cable

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

SWS10 SWS20 SWS30

5K, 10K 25K, 50K 100K

1. Height Total 2.56 3.67 4.65 2. Max. Clearance Radius 2.53 3.50 4.50 3. Cell and Base Diameter 4.12 6.06 8.00 4. Cell Height to Hub 1.38 1.75 2.50 5. Cell Body Height 1.25 1.63 2.25 6. Hub Diameter 1.29 2.34 25K/2.58 50K 3.76 7. Mounting B.C. Diameter 3.50 5.13 6.50 8. Symmetric B.C. Offset 22.5 Degrees 15 Degrees 11.25 Degrees 9. Mounting Hole Diameter .28 .41 .53 10. Hub Thread 5/8 - 18, 1.12 Dp. 1 1/4 - 12, 1.50 Dp. 1 3/4 - 12, 2.20 Dp. 11. Bolt Head Protrusion .18 .29 .40 12. Base Thickness 1.13 1.75 2.00 13. Base Step Height .03 .03 .03 14. Base Step Diameter 1.25 2.25 3.00 15. Base Thread 5/8 - 18, .88 Dp. 1 1/4 - 12, 1.50 Dp. 1 3/4 -12, 1.75 Dp.

Page 54

Page 60: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

STAINLESS STEEL LOAD CELLS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

FRS10 FRS20

2.5K, 5K 12.5K, 25K

FATIGUE RATED STAINLESS STEEL (FRS SERIES)FORCE TRANSDUCERS

FEATURESStainless Steel ConstructionWelded DiaphragmOptional Hermetically Sealed ConnectorGuaranteed Maximum Off-Center Load and Moment ErrorLow CreepTemperature CompensatedBarometric Pressure Compensation

Static Error Band, % R.O. +/-.05 +/-.05Nonlinearity, % R.O. +/-.05 +/-.05Hysteresis, % R.O. +/-.06 +/-.06Nonrepeatability, % R.O. +/-.01 +/-.01Creep, % in 20 minutes +/-.025 +/-.025Off-Center Load Sensitivity, % /inch +/-.25 +/-.25Side Load Sensitivity, % /inch +/-.25 +/-.25Zero Balance, % R.O. +/-1.0 +/-1.0

Range, Compensated, °F +15 to +115 +15 to +115 Range, Operating, °F -65 to +200 -65 to +200 Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.15 +/-.15

Rated Output, mV/V, Nominal 2.0 2.0Excitation Voltage, VDC, Recommended 10 10Input Resistance, Ohms 350 +40/-3.5 350 +40/-3.5 Output Resistance, Ohms 350 +/-3.5 350+/-3.5Insulation Resistance, Megohm 5000 @ 50 VDC 5000 @ 50 VDC

Safe Overload Range, % R.O. +/-300 +/-300Flexure Material Stainless Steel Stainless Steel

Mechanical

Electrical

Temperature

Accuracy

Note: Shown with Optional Connector and Connector Box.

Page 55

Page 61: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

STAINLESS STEEL LOAD CELLS

OPTIONS

Additional bridgesOutput adjustment to standardCompression overload protectionHermetically sealed connectorConnector protectionIntegral cable

Mating connectorLoading fixturesInterconnect cableShunt calibration resistorInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

FRS10 FRS20

2.5K, 5K 12.5K, 25K

1. Height Total 2.56 3.67 2. Max. Clearance Radius 2.53 3.50 3. Cell and Base Diameter 4.12 6.06 4. Cell Height to Hub 1.38 1.75 5. Cell Body Height 1.25 1.63 6. Hub Diameter 1.29 2.34 25K/2.58 50K 7. Mounting B.C. Diameter 3.50 5.13 8. Symmetric B.C. Offset 22.5 Degrees 15 Degrees 9. Mounting Hole Diameter .28 .41 10. Hub Thread 5/8 - 18, 1.12 Dp. 1 1/4 - 12, 1.50 Dp. 11. Bolt Head Protrusion .18 .29 12. Base Thickness 1.13 1.75 13. Base Step Height .03 .03 14. Base Step Diameter 1.25 2.25 15. Base Thread 5/8 - 18, .88 Dp. 1 1/4 - 12, 1.50 Dp.

Page 56

Page 62: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

STAINLESS STEEL LOAD CELLS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

4110 4110

500, 1K 2K, 5K

MODEL 4110 STAINLESS STEELFORCE TRANSDUCERS

FEATURESStainless Steel ConstructionCompact SizeWelded DiaphragmTension and CompressionOptional Hermetically Sealed ConnectorOptional BaseCounterbored Mounting Holes

Static Error Band, % R.O. +/-.10 +/-.10Nonlinearity, % R.O. +/-.10 +/-.10Hysteresis, % R.O. +/-.08 +/-.08Nonrepeatability, % R.O. +/-.02 +/-.02Creep, % in 20 minutes +/-.05 +/-.05Zero Balance, % R.O. +/-2.0 +/-2.0

Range, Compensated, °F +15 to +115 +15 to +115 Range, Operating, °F -65 to +200 -65 to +200 Effect on Sensitivity, % Rdg/100°F +/-.20 +/-.20Effect on Zero, % R.O./100°F +/-.20 +/-.20

Rated Output, mV/V, Nominal 3.0 3.0Excitation Voltage, VDC 10 10Input Resistance, Ohms 350 350Output Resistance, Ohms 350 350Insulation Resistance, Megohm 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150Weight (lbs.) 1.5 2.0Flexure Material Stainless Steel Stainless Steel

Mechanical

Electrical

Temperature

Accuracy

Page 57

Page 63: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

1

2

3

4

5

7

8

69

10

12

11

STAINLESS STEEL LOAD CELLS

OPTIONS

Hermetically sealed connectorSpecial connector orientationLoad button

Mating connectorLoading fixturesInterconnect cableInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)

1. Height Total 2.00 2.00 2. Max. Clearance Radius 2.53 2.78 3. Cell and Base Diameter 3.00 3.50 4. Cell Height to Hub 1.00 1.00 5. Box Height to Center .50 .50 6. Hub to Connector Radius 2.00 2.25 7. Hub Thread 3/8 - 24 UNF 3B 1/2-20 UNF 3B 8. Mounting B.C. Diameter 2.50 2.63 9. Bolt Spacing 60 Degrees 60 Degrees 10. Mounting Hole Diameter C’Bore for 1/4 -28 C’Bore for 5/16-24 11. Base Thread 3/8 - 24 UNF 3B, .70 Dp. 1/2 - 20 UNF 3B, .70 Dp. 12. Connector MS3112E10-6P MS3112E10-6P

Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

4110 4110

500, 1K 2K, 5K

Page 58

Page 64: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

MODEL

CAPACITY (lbf)

SPECIFICATIONS

STAINLESS STEEL LOAD CELLS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

4120 4120

10K 20K

MODEL 4120 STAINLESS STEELFORCE TRANSDUCERS

FEATURESStainless Steel ConstructionWelded DiaphragmTension and CompressionOptional Hermetically Sealed ConnectorOptional BaseCounterbored Mounting Holes on 10K Model

Static Error Band, % R.O. +/-.10 +/-.10Nonlinearity, % R.O. +/-.10 +/-.10Hysteresis, % R.O. +/-.08 +/-.08Nonrepeatability, % R.O. +/-.02 +/-.02Creep, % in 20 minutes +/-.03 +/-.05Zero Balance, % R.O. +/-2.0 +/-2.0

Range, Compensated, °F +15 to +115 +15 to +115 Range, Operating, °F -65 to +200 -65 to +200 Effect on Sensitivity, % Rdg/100°F +/-.15 +/-.15Effect on Zero, % R.O./100°F +/-.15 +/-.15

Rated Output, mV/V, Nominal 3.0 3.0Excitation Voltage, VDC 10 10Input Resistance, Ohms 350 350Output Resistance, Ohms 350 350Insulation Resistance, Megohm 5000 5000

Safe Overload Range, % R.O. +/-150 +/-150Weight (lbs.) 6 9Flexure Material Stainless Steel Stainless Steel

Mechanical

Electrical

Temperature

Accuracy

Page 59

Page 65: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

STAINLESS STEEL LOAD CELLS

OPTIONS

Hermetically sealed connectorSpecial connector orientationConnector protectionLoad buttonOutput adjustment to standardOverload protection

Mating connectorLoading fixturesInterconnect cableInstrumentation

ACCESSORIES

MODEL

CAPACITY (lbf)

1. Height Total 3.55 3.83 2. Max. Clearance Radius 3.39 3.62 3. Cell and Base Diameter 5.50 6.00 4. Cell Height to Hub 1.80 1.80 5. Base Thickness 1.75 1.75 6. Bolt Head Protrusion NA .38 7. Hub Thread 1 - 14 UNF 3B 1 1/2 - 12 UNF 3B 8. Mounting B.C. Diameter 4.50 4.88 9. Symmetric B.C. Offset 22.5 Degrees 22.5 Degrees 10. Mounting Hole Diameter C’Bore for 3/8 -24 .53 11. Base Thread 1 - 14, 1.65 Dp. 1 1/2 - 12, .1.65 Dp. 12. Connector MS3102E14S-6P MS3102E14S-6P

Review Drawing(in inches)

DIMENSIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

4120 4120

10K 20K

1

2

3

4

5

7

8

6

9

10

11

12

Note: 20K drawing shown. 10K package has counterbored mounting holes.

Page 60

Page 66: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

SPECIFICATIONS

2100 SERIES COMPACT STAINLESS STEELCOMPRESSION LOAD CELLS

STAINLESS STEEL LOAD CELLS

FEATURES

Static Error Band, % R.O. +/-.07Nonlinearity, % R.O. +/-.07Hysteresis, % R.O. +/-.05Nonrepeatability, % R.O. +/-.01Creep, % in 20 minutes +/-.025Zero Balance, % R.O. +/-1.0

Range, Compensated, °F 15 to +115 Range, Operating, °F -30 to +200 Effect on Sensitivity, % Rdg/100°F +/-.10Effect on Zero, % R.O./100°F +/-.15

Rated Output, mV/V, Nominal 2.0Excitation Voltage, VDC 10Input Resistance, Ohms 350Output Resistance, Ohms 350Insulation Resistance, Megohm 5000

Safe Overload Range, % R.O. +/-150Weight, lbs. 3.6Flexure Material Stainless Steel

Mechanical

Electrical

Temperature

Accuracy

Compact SizeAccuracy--.05% - ..07% of R.O.Optional Full Encapsulation for Harsh Environments

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

MODEL 2100 DIMENSIONS

1. Total Height 3.25 2. Max. Clearance Radius 2.69 3. Diameter 2.88 4. Button Diameter 1.25 5. Spherical Radius 66. Button Height .407. Height to Connector Center 1.728. Center to Connector Radius 2.049. Base Thread 1/2 - 20, .5 Dp.10.Connector MS3102E14S-6P

Capacity (lbf)

10K, 25K Review Drawing

1

10

98

7

65

4

3

2

MODEL 2100

Capacity (lbf)

10K, 25K

Page 61

Page 67: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

SPECIFICATIONS

AXIAL FORCE AND TORQUE (SWT) SERIESTRANSDUCERS

MULTI-AXIS LOAD CELLS

FEATURES

Nonlinearity, % R.O. +/-.04 +/-.07Hysteresis, % R.O. +/-.04 +/-.05Nonrepeatability, % R.O. +/-.02 +/-.05Creep, % in 20 minutes +/-.025 +/-.025Zero Balance, % R.O. +/-2.0 +/-2.0

Range, Compensated, °F +15 to +115 +15 to +115Range, Operating, °F -65 to +200 -65 to +200Effect on Sensitivity, % Rdg/100°F +/-.08 +/-.08Effect on Zero, % R.O./100°F +/-.15 +/-.15

Rated Output, mV/V, Nominal 1.5 1.8Excitation Voltage, VDC 10 10Input Resistance, Ohms 700 700Output Resistance, Ohms 700 700Insulation Resistance, Megohm 5000 5000

Safe Overload, % R.O. 200 200Flexure Material Steel Steel

Mechanical

Electrical

Temperature

Accuracy

Measure both Force and TorqueHigh Accuracy Both BridgesLow CrosstalkLow Creep

MODEL SWT DIMENSIONS

1. Total Height 3.63 2. Max. Clearance Radius 2.53 3. Total Diameter 4.12 4. Mounting Hole Thread 3/8 - 24, .66 Dp. 5. Locating Hole Diameter .25 on 3.00 B.C.6. Base Thread 5/8 - 18, .95 Dp.7. Connector MS3112E10-6P

Review Drawing

MODEL SWT

Capacity (lbf. / in.-lb)

Axial ForceBridge

TorqueBridge Capacity

(lbf. / in.-lb)

300/150, 500/250, 1K/5002K/1K, 5K/2.5K

1

2

37

5

4

5

4

6

(in inches)300/150, 500/250,

1K/500, 2K/1K, 5K/2.5K

Page 62

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 68: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

SPECIFICATIONS

SW-XYZ SERIES AXIAL FORCEAND MOMENT TRANSDUCERS

MULTI-AXIS LOAD CELLS

FEATURESMeasure Z-Axis Force, X- and Y-Axis MomentHigh Accuracy Force Measurement Other Features Identical to SW Series.

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

DIMENSIONS

Dimensions are identical to SW Series Shear Web Load Cells in equivalent capacities.

Specifications for the force axis measure-ment are identical to the SW Series.

Accuracy of each moment axis measure-ment is +/-1% of Rated Moment.

CAPACITIES

1K 4002K 8005K 1K

10K 2K

25K 10K50K 20K

SW10-XYZ

Force Moment

SW20-XYZ

lbf in-lbf

SW30-XYZ100K 50K

Page 63

Page 69: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PARAMETERS

SPECIFICATIONS

MINIATURE REACTION TORQUE (RT) SERIESTORQUE TRANSDUCERS

REACTION TORQUE CELLS

FEATURES

Nonlinearity, % R.O. +/-.10Hysteresis, % R.O. +/-.10Nonrepeatability, % R.O. +/-.05Creep, % in 20 minutes +/-.10

Range, Compensated, °F 15 to +115 Range, Operating, °F -65 to +200 Effect on Sensitivity, % Rdg/100°F +/-.10Effect on Zero, % R.O./100°F +/-.20

Rated Output, mV/V, Nominal 2.0Excitation Voltage, VDC 10Input Resistance, Ohms 700Output Resistance, Ohms 700Insulation Resistance, Megohm 5000

Safe Overload, % R.O. 150Flexure Material Aluminum

Mechanical

Electrical

Temperature

Accuracy

Compact SizeAccuracy--.1% of R.OCapacities from 25 to 500 in-lb.

MODEL RT DIMENSIONS

1. Total Height 1.00 2. Max. Clearance Radius 1.54 3. Total Diameter 1.64 4. Flexure Diameter 1.38 5. Mounting B.C. Diameter 1.00 6. Mounting Hole Thread 10 - 32 UNF 2B7. Locating Hole Diameter .125 +/-.0058. Center Hole Diameter .259. Cable 4 Conductor

Cable w/Pig Tails

Capacity (in-lb)

25, 50, 100 200, 250, 500

Review Drawing

1

9

8

76

5

4

3

2

MODEL RT

Capacity (in-lb)

25, 50, 100 200, 250, 500

(in inches)

Page 64

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 70: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 65

PerformanceFull Scale Selectable, 0.01 - 999,999Resolution 20 bit, 100,000 divisions displayedA/D Conversion 60 HzNon-Linearity 0.005% of full scaleZero Track 10 displayed divisionsZero Range Selectable from 0% - 100%Display Units kg, lb, g, lb oz, oz

ElectricalPower Input 12-26 VAC/12-36 VDC

Load Cell InputConnections 4 lead or 6 lead with sensePower 6 350-ohm cellsSignal Range 0.1 to 20 mV/VExcitation 10 VDC with short circuit protectionCurrent 180 mA maximum

CommunicationsComputer Interface RS-232 serial portBaud Rate 150-9600 bpsProtocal SelectableFormatting Selectable

DisplayDisplay Type LEDDecimal Point SelectableDisplay Values -99,999 through 99,999

EnclosureMaterial Zinc Die CastWidth 7.83 in (199 mm)Height 5.75 in (146 mm)Depth 2.65 in (67 mm)

MODEL 7010 GENERAL PURPOSE INDICATOR

SPECIFICATIONS

INSTRUMENTS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

20-bit Resolution 10-point LinearizationPortable with Rechargeable BatterySensitivity .1 - 20 mV/VLinearity of 0.005% of Full ScaleSelectable Units kg, lb, g, lb oz, ozRS-232 or RS-485 Computer Interface

Page 71: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 66

PerformanceFull Scale SelectableResolution 100,000 displayed (+/- 500,000)Display Update SelectableA/D Conversion 60 HzNon-Linearity 0.005% of full scaleZero Track 0.05-20.0 displayed divisionsZero Range Selectable from .01% - 100%Calibration Selectable, 5 multi-point calibrationDivision Size 0.00001 through 500

ElectricalPower Input 90-250 VAC, 50-60 Hz, 10-32 VDCFuse 0.8 Amp time lag

Load Cell InputConnections 4 lead or 6 lead with sensePower 12 350-ohm cellsSignal Range 0.1 to 20 mV/VExcitation 10 VDC with short circuit protectionCurrent 400 mA maximum

CommunicationsComputer Interface RS-232 serial portBaud Rate SelectableProtocal SelectableFormatting Selectable

DisplayDisplay Type Vacuum fluorescentDecimal Point SelectableDisplay Values -99,999 through 99,999

EnclosureMaterial Stainless SteelWidth 11 in (279 mm)Height 9 in (228 mm)Depth 4.4 in (112 mm)

MODEL 7120 SEALED GENERAL PURPOSE INDICATOR

SPECIFICATIONS

INSTRUMENTS

Sealed Enclosure for Harsh Environments20-bit Resolution 5-point LinearizationLegal for Trade CapabilityLb and Kg Measurement UnitsRS-232 Computer Interface

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 72: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 67

Transducer InterfaceExcitation 5VDC or 10 VDC software/auto selectableCurrent Drive 180 mA at 5 VDC or 10 VDC Push Button Shunt YesInternal Shunt Rstor 1 standard, 2 optional. Rear panel selectableCalibration Method Shunt, mV/V, Known LoadPush Button Tare 100% of range--display and analog outputSensitivity Adjust 1 mV/V to 4.5 mV/VAccuracy 0.005% of full scale +/- digital countCMRR 115 dB

Transducer ChannelsNumber of Channels 1 std, 2 optional

D/A Analog OutputFull Scale Output +/- 10 VDC nominal +/- 0.5 VDCLinearity 0.02% of full scaleScaling Gain and offset selected softwareFrequency Response Approx. 15 Hz (plus filtering)Output Source Any displayed quantity

Direct Analog OutputFull Scale Output +/- 8.14 VDC +/- 0.25 VDCLinearity 0.02% of full scaleScaling Fixed with no tare, transducer channel onlyFrequency Response Approx. 1.5 kHz

Digital I/OInputs--Interface 4 optically isolated inputsOutputs--Quad Limits 4 isolated solid state switches

Serial InterfaceRS-232, RS-485 Standard, OptionalDisplay Values -999,999 through 999,999

Auto Transducer I.D.Auto I.D. and Setup Standard

MODEL 9150 HIGH PRECISION INDICATOR

SPECIFICATIONS

INSTRUMENTS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

24-bit Resolution10-point Linearization Linearity of 0.005% of Full ScaleSensitivity of +/-4.5 mV/V2 Channel Transducer InputSoftware Selectable FiltersRS-232 or RS-485 Computer Interface

Page 73: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 68

MODEL 9250 PRECISION DIGITAL SIGNAL CONDITIONER

SPECIFICATIONS

INSTRUMENTS

2-pt Calibration6-pt Linearization Calibration1-pt mV/V CalibrationScalable +/-10V Analog Output16-Bit Analog OutputDirect to PC with RS-232 Data24-Bit ResolutionMultiple Filter SelectionsStorage for Two Calibrated TransducersRemote Sense ExcitationAddressable for Serial NetworkTare, Peak, ValleySynchronized Sample CollectionTemperature CompensationUnits Supported: lb, kg, in, cm, mm, %

ExcitationVoltage 5 VDCNominal Load 350 Ohms

OperationInternal Resolution 24-bitInput Range +/-5.5 mV/V (up to +200 mV/V available)Conversion Rate 60 per secondError 0.01%, +/-1 count

OutputsAnalog 16-bit, scalable, +/-10VSerial Data Multi-drop RS232

PowerPower 5 VDC, 150 mAAdapter 110/240 VAC, 60/50 Hz

MechanicalDimensions 5.5”L x 2.75”W X 1.2”HWeight 8.3 oz. (235 g)

The Model 9250 Digital Signal Conditioner is a precision digitizing signal conditioner that is designed to amplify, filter, and linearize the output of a strain gage sensor and present the user with an idealized analog output voltage and a serial RS-232 data output suitable for direct connection to a PC.

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 74: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 69

MODEL 460 BRIDGESENSOR

INSTRUMENTS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

2 kHz Frequency ResponseRugged, Compact and Fully EncapsulatedComplete System--Just Add A/C PowerReady to Use with Screwdriver WiringStable and Accurate

Applications: Weighing with Load Cells Long Term Structural Monitoring Process Control Pressure Transducers Strain Measurements

PerformanceGain Range 40 - 250Gain Temp. Coeff. 200 ppm/°C Drift 3 μV/°COutput Noise 2 mV P-P @ gain = 100 1 Hz to 2 HzDynamic Response 2 kHz

Input/OutputInput 115 VAC +/- 10% 50 to 60 Hz

100, 220, and 230 VAC availableInput Range +/- 2.0 mV/V to +/- 6.0 mV/VOutput, Current 120 mAOutput, Voltage 4 to 15V

SizeLength 3.75” (95mm)Width 2.00” (51mm)

SPECIFICATIONS

The Model 460 Bridgesensor is a self contained, AC powered, signal conditioning module for bridge type instrumentation. It contains a precision differential instrumentation amplifier with filtered output and a highly regulated, low noise, adjustable output bridge excitation source. The unit is completely encapsulated for use in rugged environments. The output filter cutoff frequency is 2000Hz and may be lowered by two external capacitors.

Page 75: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

PerformanceGain Range 40 - 250, to 1,000 with external R Gain Temp. Coeff. 200 ppm/°C Drift 2 +/-20/G μV/°COutput Noise 120 μV RMS @ gain = 100 1 Hz to 2 HzDynamic Response .3s to .1%

Input/OutputInput 115 VAC +/- 10% 50 to 60 Hz

100, 220, and 230 VAC availableInput Range +/- 2.0 mV/V to +/- 6.0 mV/VOutput, Current 5-150 mAOutput, Voltage 4-15V

SizeLength 3.75” (95mm)Width 2.00” (51mm)

Page 70

MODEL 465 BRIDGESENSOR

INSTRUMENTS

Rugged, Compact and Fully EncapsulatedComplete System--Just Add A/C PowerReady to Use with Screwdriver WiringStable and Accurate

Applications: Weighing with Load Cells Long Term Structural Monitoring Process Control Pressure Transducers Low Frequency Strain Measurements

SPECIFICATIONS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

The Model 465 Bridgesensor is a self contained, AC powered, signal conditioning module for bridge type instrumentation. It contains a precision differential instrumentation amplifier with filtered output and a highly regulated, low noise, adjustable output bridge excitation source. The unit is completely encapsulated for use in rugged environments.

Page 76: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 71

PerformanceFull Scale SelectableResolution (bits) 24 bitsResolution (counts) 250,000 counts/divisions @ 1Hz sample rateResolution (counts) 65,000 counts/divisions @ 10 Hz sample rateTemp. Effect on Zero 0.05% FS/100°CTemp. Effect on Span 0.07% FS/100°CNon-Linearity 0.005% of FSOff-Set Stability 0.008% of FSGain Stability .01% per yearExcitation Voltage 5.2 VdcBattery Life 35 hours continuous operationUpdate Rate 10 mS to 2s including peak/valley hold rate

Power & ElectricalPower Input 2 AA alkaline batteriesElectrical Connection 5 pin binder socket (mating plug supplied).

IndicationDisplay Type 7 1/2 digit LCD display, 8.8mm high digitsDisplay Resolution 1 part in 250,000 at 1s updateAnnunciators Low battery warning, peak, trough, hold,

net, shunt cal, range, by LCD annunciators

EnclosureType ABS, dark grey (optional carrying case)Width 90 mmHeight 152 mmDepth 34 mm

MODEL 7230 PORTABLE STRAIN DISPLAY LOAD CELL INDICATOR

SPECIFICATIONS

INSTRUMENTS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Portable Handheld InstrumentPowered by 2 AA Internal BatteriesEnvironmentally Sealed to IP65/NEMA 4Dual Range Selection7 1/2 Digit LCD DisplayOptional RS-232 Computer Interface

Page 77: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 72

Power Supply (SGA/A) 110/230 V ACPower Supply DC 18-24 V DCPower Supply Current 200 mABridge Excitation 10 V (350R Strain Gage)Bridge Resistance 85 OhmsBridge Sensitivity (Switchable) 0.06 Min - 29 Max mV/VGain Adj. (Pot-fine adj.) 0.06 Min - 1.0 Max mV/VOffset Adj. (Pot-fine adj.) -1.25 Min - 1.25 Max %FSOffset Adj. (Switchable-course adj.) +/-1.25 Min - +/-79 %FSOutput Load (Voltage output) 2 mAOutput Load (Current output) 0 - 500 OhmsTemp. Effect on Zero 0.09% FS /100 °CTemp. Effect on Span 1.0% FS /100 °CNon-linearity 0.03% % FS Gain Stability 0.2% FS (1st 1000 hrs) Output Load Stability Gain (0-100%) .01% FSOutput Load Stability Off-set (0-100%) .01% FSPower Supply Reject. Gain (0-100%) .01% FSPower Supply Reject. Offset (0-100%) .01% FSOperating Temperature Range -20 - 50°CHumidity Range 0-95%

SGA/A & SGA/D STRAIN GAGE AMPLIFIER

SPECIFICATIONS

INSTRUMENTS

10V Excitation for up to 4 x 350R BridgesAdjustable Sensitivity 0.1 to 30 mV/VUser Selectable Analog OutputSimultaneous Voltage and Current OutputDirect Connection to PLC, Display, InstrumentLVDT Version Available

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 78: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 73

Bipolar Analog Analog Current Digital Output7510 7520 7530

Excitation Voltage 10VDC 10VDC 5VDCInput Range +/-32mV -2 to +23mV +/-11mVLoad Cell Drive Capability, Ohms 200 to 2000 350 to 2000 350

Zero Set, Fixed Binary Steps +/-7mV; 1mV incr. 0 to +15mV; 1mV incr. Zero Set, Fine Trim +/-1.5mV -1.5mVGain Set, Fixed Binary Steps Range 1* to 8* as 8 increments 1*: 32mV at +/-10V 1*: 20mV for 20mA of 1* per incr. (input for output) 8*: +/-4mV at +/-10V 8*: 2.5mV for 20mAGain Set, Fine Trim +/-1.5mV -1.2*, 25 turn pot (opt.)

Non-Linearity .01% .01% .01%Resolution Readout dependent Readout dependent 0.2uVTemp. Effect on Zero/°C <50ppm <50ppm <50ppmTemp. Effect on Span/°C <50ppm <50ppm <20ppmTemp. Compensated Range, °C -10 to +40 -10 to +40 -10 to +40Temp. Operating Range, °C -20 to +50 -20 to +50 -20 to +50

Power Supply 12-16VDC; 70mA 12-24VDC; 50-80mA 12-24VDC; <24mAUnit Size 81x31X6mm 81x31x6mm 81x31x6mm

LOAD CELL INSTRUMENT (7500 SERIES) MODULES

SPECIFICATIONS

INSTRUMENTS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Output Options: Bipolar Analog Voltage Output (+/-10V) Analog Current Output (0-20mA or 4-20mA) Digital Output (RS-422 or RS-485 Outputs)Simple InstallationPrecision and Speed at Low CostReliable in Electrically Hostile Environments

Analog Units: 10V analog current output and bipolar voltage output for single strain gage load cell; convert output at excellent resolution, linearity, and stability; wide range of zero, gain, and filter settings. Optional motherboard.

Digital Unit: Digital output for single strain gage load cell; two isolated logic inputs can define a time frame for automatic operations; signal conditioning, zero, and tare operations convert load cell output to kg, lbs, etc.; convert output with 16 bit resolution at 105 conversions/second; allows pt.-to-pt. or node-in-network data communication.

Page 79: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement
Page 80: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 75

SPECIFICATIONS

COMPRESSION ACCESSORIES

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Compression Plates

Load Buttons

Dimensions P/N Thread Size Figure H / D 1 2 R

LB-099 1/4-28 1 .44 .63 .50 2 LB-100 1/2-20 1 .75 1.05 .30 4 LB-101 5/8-18 1 .94 1.41 .41 4 LB-102 1-14 1 1.5 2.12 .63 4 LB-103 1 1/4-12 2 2.25 2.38 .88 6 LB-104 1 3/4-12 2 3.76 3.34 1.34 12 LB-105 2 3/4-8 2 4.00 3.40 1.40 12 LB-106 4 - 8 2 7.89 4.39 2.89 20

Dimensions P/N Thread Size D L1 L2

CP-100 1/2-20 1.47 1.38 .63 CP-101 5/8-18 1.47 1.38 .63 CP-102 1-14 2.00 2.00 .63 CP-103 1 1/4 -12 2.00 2.00 .63 CP-104 1 3/4 - 12 2.50 2.25 .75 CP-105 2 3/4 - 8 4.00 2.50 .75 CP-106 4 - 8 6.00 3.75 .75

Page 81: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 76

ADAPTERS AND JAM NUTS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Calibration Adapters

Thread Adapters

Thread Size Dimensions P/N Male Female Jam Nut D 1 2

TAMF-100 1/2-20 1/2-20 JN-100 TAMF-101 5/8-18 5/8-18 JN-101 TAMF-102 1-14 1-14 JN-102 TAMF-103 1 1/4-12 1 1/4-12 JN-103 TAMF-104 1 3/4-12 1 3/4-12 JN-104 TAMF-105 2 3/4-8 2 3/4-8 JN-105 TAMF-106 4-8 4-8 JN-106

Size Dimensions P/N (Both Ends) Jam Nut D L1 L2 L3 R

TAMM-100 1/2-20 male JN-100 1.28 .75 1.50 2.75 6 TAMM-101 5/8-18 male JN-101 1.28 .75 1.57 2.82 6 TAMM-102 1-14 male JN-102 2.00 1.50 2.15 4.15 6 TAMM-103 1 1/4-12 male JN-103 2.00 1.50 2.32 4.32 6 TAMM-104 1 3/4-12 male JN-104 2.74 1.75 3.27 5.52 6 TAMM-105 2 3/4-8 male JN-105 3.50 2.50 5.03 8.28 12 TAMM-106 4-8 male JN-106 7.00 3.50 7.25 12.25 20

Tovey Engineering offers hundreds of adapter designs and makes custom adapters for virtually any application.

Page 82: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 77

SPECIFICATIONS

ADAPTERS AND JAM NUTS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Couplers

Jam Nuts

Dimensions P/N Thread D T

JN-100 1/2-20 1.29 .31 JN-101 5/8-18 1.29 .38 JN-102 1-14 2.00 .55 JN-103 1 1/4-12 2.16 .72 JN-104 1 3/4-12 3.17 .97 JN-105 2 3/4-8 4.75 1.58 JN-106 4-8 7.00 2.19

Dimensions P/N Thread Size D 1 H

TAFF-099 1/4-28 .47 1,00 .42 flat TAFF-100 1/2-20 1.22 2.00 3/16 TAFF-101 5/8 -18 1.36 2.00 3/16 TAFF-102 1 -14 1.97 3.00 1/4 TAFF-103 1 1/4 - 12 2.25 3.00 1/4TAFF-104 1 3/4 - 12 3.00 4.00 1/4 TAFF-105 2 3/4 - 8 5.30 5.50 3/8

Page 83: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 78

INSTRUMENTS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

INTERCONNECT CABLES AND CONNECTORS

Instrument Cables

P/N Description

MC-100 MS3116-10-6S (PT06F-10-6S), mating connectorMC-200 MS3112-10-6P (PT02E-10-6P), load cell connector MC-101 Bendix PC04E-10-6P load cell connectorMC-111 Bendix PC06W-10-6S mating connectorMC-102 MS3106-14S-6S mating connector

Connectors

P/N Description

CBL-101-10 Interconnect Cable, 7 wire to 4 pins, MS3116F-10-6S to pigtail, 10’ CBL-102-10 Interconnect Cable, 7 wire to 6 pins, MS3116F-10-6S to pigtail, 10’ CBL-108-10 Interconnect Cable, 7 wire, MS3116F-10-6S to 9150 instrument

mating connector, 6-4 adaption made on MS3116 connector, 10’ CBL-120-10 Interconnect Cable, 7 wire, MS3116F-10-6S to 9150 instrument

mating connector, 10’ CBL-121-10 Interconnect Cable, 2150 Instrument to MS3116E-10-6S, 10’ CBL-122-10 Interconnect Cable, 6 wire, MS3116F-10-6S to Vishay Model 2310

signal conditioner, 10‘ CBL-123-10 Serial Cable, 9150 instrument (DB-15) to computer (DB-9), 10’ CBL-126-25 Interconnect Cable, PT06E-10-6S to PT06E-14S-6P, 25’

Page 84: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 79

SPECIFICATIONS

OPTIONS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Tovey Engineering offers the following load cell options:

Additional Bridges: Additional bridges provide separate independent electrical measurement circuits, producing isolated measurement outputs. Additional bridges are often used for measurement redundancy or control. Dual bridges are commonly used; occasionally, triple or quad bridges are used. Most Tovey models accomodate additional bridges.

Output Adjustment to Standard Value: Typical variation in load cell output may fall between +/-10% of the nominal specified output. If desired, the load cell sensitivity can be adjusted to within +/-0.1% of the nominal output.

Compression Overload Protection: Typical safe overload values are in the range of 150%-200% of rated load cell output. On Tovey Shear Web models, overload protection to 500% of rated load can be provided by carefully controlling the clearance gap between the load cell hub and base.Some other model types, including the SCT S-cell, are specially designed to be tolerant of overload situations.

Integral Cable: In some cases, it may be desirable to have an integral cable rather than a connector on a load cell. Substitution of a cable is possible for most Tovey load cell models.

Custom Connectors: Many customers have adopted standard connectors for use in their facilities. In most cases, these special connectors can be placed on Tovey load cells in place of standard connectors.

TEDS (Transducer Electronic Data Sheet): Electronic identification is available for most Tovey load cell models. Identification is compatible with IEEE 1451.4 TEDS standards.

On-Board Electronics: Optional on-board electronics are available on most Tovey load cell models. Electronic modules are available providing bi-polar voltage output, current output, and serial digital output.

Page 85: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 80

CALIBRATION AND TEST SOFTWARE

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Calibration and Test Software

Tovey Engineering offers several software packages to support calibration and testing. The software is applicable to strain gage based force, torque, and pressure transducers. Available software packages include:

CalSoft-DW for dead weight calibration systems.

CalSoft-FTS for transfer standard calibration systems.

CalAnalysis for comprehensive data analysis.

CalSoft-Test for test applications.

Software Features:

> Supports automated or manual exercise cycles.

> Supports automated or manual load setting.

> Automated data acquisition.

> Performs standard performance analysis including determining non-linearity, hysteresis, and static error band.

ASTM E74 Analysis.

ISO 376 Analysis.

All data presented graphically or in tabular form.

> Statistically determines degree of curve fit according to ASTM E74 procedure, or user may override to select from 1st to 5th degree.

> Calibrates stand-alone systems with indepen-dent readout instruments.

> Allows simultaneous calibration of bridges in bridge transducers.

> Can be customized to meet special customer requirements.

Page 86: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 81

SPECIFICATIONS

FORCE CALIBRATION SERVICES

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Calibration Services

Tovey Engineering offers accredited force calibration services from 1 gf to 1 million lbf. State-of-the-art calibration facilities include both deadweight and servo-controlled hydraulic transfer standard calibration rigs. Force calibrations are performed in compliance with NVLAP requirements (under NVLAP Lab Code 200662-0), and meet the requirements of NIST Handbook 150, ISO/IEC 17025 and ANSI Z540.

Experienced Staff, Quick Turnaround

Calibrations are performed by experienced and knowledgeable technical staff. The calibration lab is overseen by the current Chairman of ASTM Committee E28.01 for calibration of load cells and testing machines, a NVLAP Technical Expert in force calibration. All force calibrations are performed quickly and efficiently to minimize customer downtime.

Page 87: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 82

FORCE CALIBRATION SERVICES

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Calibration Reports

Customers receive comprehensive reports with calibration data presented in both graphical and tabular form. All data analysis and output is compliant with national and international standards.As an example, a standard E74 report package includes a Certificate of Calibration, a Calibration Report, a curve fit analysis report and associated graphs for tension and compression. Additional graphical representations of calibration data can be supplied upon request.

Page 88: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 83

SPECIFICATIONS

CALIBRATION SYSTEMS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Force Calibration Systems

Tovey Engineering transfer standard force calibration systems are available in sizes ranging from 20 lbf to 1 million lbf. These versatile automated calibration systems reduce calibration time and cost, permitting efficient in-house transducer calibration. Systems meet ASTM E74 required measurement uncertainty of applied forces of less than 0.005% of range, or overall measurement uncertainty of 0.025%-0.050% of reading.

11K lbf Force Calibration System

Portable 3K lbf Force Calibration System

Features:

> Systems include load frame, transfer standard load cells, hydrau-lic actuator, and automated control and data analysis software.

> Durable multi-column load frames exhibit high frame stiffness, highly symmetric stiffness, exceptional alignment, and precision machining.

> Universal fixturing allows tension and compression calibration without changeover.

> Included metrology grade transfer standards exhibit industry leading accuracy, meeting the lowest specifications of any load cell manufacturer.

> Systems enable fully automated calibration; exercise transducers automatically with specified forces and number of cycles.

> Calibrate transducers in load sequences using up to thirty different load points with simultaneous measurement of up to three bridges.

> Automated closed-loop system calculates performance param-eters and performs data evaluations per ASTM E74 and/or ISO 376.

> Model 9150 ratio-metric instruments provide excitation of 5 or 10 Voltz, signal conditioning and A to D conversion with 24 bit digital resolution and a useable resolution to < 100 nanovoltz. Linear-ization at up to 10 points can be performed.

> Model TS-10-2 Transducer Simulator with 30ppm measurement uncertainty (1 year) simplifies instrument calibration and provides an instrument check standard.

> Data files and graphs for calibration records are produced and stored.

> Data analysis and output is compliant with national and interna-tional standards.

Accreditations: NVLAP Lab Code 200662-0ANSI Z540, ISO/IEC 17025ASTM E74, ISO 376

Page 89: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 84

CALIBRATION SYSTEMS

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Load frames 3K-55KDimension Capacity > 3K 11K 55K

A Base Depth 29 in (74 cm) 29 in (74 cm) 29 in (74 cm)

B Base width 24 in (61 cm) 24 in (61 cm) 24 in (61 cm)

C Workingdiameter

12.9 in max(32.8 cm)

15.3 in max(38.9 cm)

14.9 in max(37.9 cm)

D Overall height 76 in (193 cm) 83 in (211 cm) 98 in (249 cm)

E Verticalworking space

21.5-30.0 in(54.6 cm-76.2 cm)

21.0-30.0 in(53.3 cm-76.2 cm)

29.0-40.0 in(73.7 cm-101.6 cm)

F Thread size 1/2-20 UNC 3A(Both ends)

1-14 UNS 3A(Both ends)

1 3/4 -12 UN 3A(Both ends)

G Columnopening

10.8 in max(27.4 cm) 13.2 in (33.5 cm) 12.6 in (32 cm)

Weight ofload frame

480 lbs(219 kg)

920 lbs(419 kg)

1,380 lbs(628 kg)

Load frames 110K-1MDimension Capacity > 110K 220K 1M

A Base Depth 29 in (74 cm) 36 in (92 cm) 38 in (97 cm)

B Base width 24 in (61 cm) 36 in (92 cm) 38 in (97 cm)

C Workingdiameter

14.9 in max(37.8 cm)

21.0 in max(53.4 cm)

34.5 in max(87.6 cm)

D Overall height 95 in (242 cm) 117 in (298 cm) 149 in (379 cm)

E Verticalworking space

29.0-38.0 in(73.7 cm-96.6 cm)

28.0-41.0 in(71.2 cm-104.2 cm)

21.5-30.0 in(54.6 cm-76.2 cm)

F Thread size 1 3/4 -12 UN 3A(Both ends)

2 3/4 -8 UN 3A(Both ends)

6 -8 UN 3A (Head)51/2-8 UN 3A (Cyl)

G Columnopening

12.6 in max(32.0 cm)

17.9 in max(45.4 cm)

23.5 in max(59.7 cm)

Weight ofload frame

1,820 lbs(828 kg)

4,900 lbs(2,228 kg)

32,000 lbs(14,545 kg)

Hydraulic pumpLength Width Height Weight Electrical Pressure

44 in(112 cm)

30 in(77 cm)

38 in(97 cm)

660 lbs(300 kg) 10 HP 4000 psi max

(282 kg/cm)

DIMENSIONS

A

B

C

G

F

E

D

Page 90: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

Page 85

SPECIFICATIONS

CALIBRATION SYSTEMS

TOVEY ENGINEERINGwww.toveyengineering.com e-mail: [email protected]

22602 N. 17th Avenue Phoenix, AZ 85027 PHONE: 623-434-5110 FAX: 623-434-5130

Torque Calibration Systems

Tovey Engineering transfer standard torque calibration systems are available in capacities ranging from 200 in-lb to 100,000 in-lb.These versatile automated calibration systems reduce calibration time and cost, permitting efficient in-house transducer calibration.

Torque Calibration Systems from 200 in-lb to 100,000 in-lb. 6,000 in-lb system shown.

Features:

> System includes torque frame, transfer standard load cells, hydraulic actuator, automated control and data analysis software.

> Precision torque arm and meticulously machined components.

> Efficient transition from clockwise to counterclockwise calibration.

> True zero deadband measurement.

> Alignment couplings to reduce transducer misalignment errors.

> Metrology grade transfer standards with industry leading accu-racy.

> Fully automated calibration; exercise transducers automatically with specified forces and number of cycles.

> Comprehensive software for data acquisition and data reduction.

> Data files and graphs for calibration records are produced and stored.

> Data analysis and output is compliant with national and interna-tional standards.

Page 91: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

TERMS AND CONDITIONS AND WARRANTYPage 86

TERMS AND CONDITIONS OF SALE AND WARRANTY

The conditions stated below shall constitute an integral part of an agreement between a buyer (”Buyer”) and Tovey Engineering, Inc. (”Tovey Engineering” or “the Corporation”) for purchase of any Tovey Engineering product.

1. WARRANTY - Products manufactured or offered for sale by Tovey Engineering, Inc. (the Corporation) are guaranteed free from defects in material or workmanship to the original purchaser for a period of 2 years for force transducers, 1 year for other manufactured parts, and manufacturer's warranty period for components, computers and other resale items from the date of shipment, when products are properly used and correctly installed. The Corporation's liability is limited to the repair or replacement of products found by our inspection to be defective upon receipt F.O.B our factory. IN NO EVENT SHALL THE CORPORATION BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THESE EXPRESS WARRANTIES SUPERCEDE ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. No agent or representative is authorized to assume for the Corporation any liability except as above set forth.

2. ACCEPTANCE - All orders based on this quotation shall be subject to the Corporation's approval and acceptance as to quantity, delivery, and other conditions not herein set forth. Orders will be accepted only on the terms and conditions expressed herein, modifying or additive terms and conditions on the customer's purchase order notwithstanding.

3. TAXES - The amount or amounts of taxes or other governmental charges upon production, sale and/or shipments of the goods sold hereunder, now imposed by any government authority or hereafter becoming effective, shall be paid by the purchaser.

4. ERRORS IN PRICE - Prices quoted shall be subject to correction for errors.

5. CANCELLATION - Orders accepted shall not be subject to cancellation except on terms that shall protect the Corporation from loss.

6. RETURN OF MATERIALS - Materials may be returned for credit only after authorization has been obtained from the Corporation, and shall be subject to handling charges to be determined by the Corpo-ration. Materials that are manufactured to special order are shipped without privilege of return.

7. SHIPMENTS AND DELIVERY - Shipping dates are approximate and based upon prompt receipt of all necessary information by the Corporation. The Corporation shall not be liable for delays in manufacture or delivery of its products. While every effort will be made to ship products on time, the Corporation assumes no liability for loss, damage, or consequential damages due to delays. All goods are shipped at the purchaser's risk. While every reasonable precaution is taken in packing, the Corporation is NOT RESPONSIBLE for goods damaged or lost in transit. Claims to recover such loss must be filed with the carrier by the purchaser.

THE TECHNICAL LEADER IN LOAD CELLS AND FORCE MEASUREMENT

Page 92: TOVEY ENGINEERING - testmart.com · TOVEY ENGINEERING The Technical Leader in Load Cells and Force Measurement The Engineer’s Choice for Force Measurement Products Force Measurement

TOVEY ENGINEERING The Engineer’s Choice for Force Measurement Products

The Technical Leader in Load Cells and Force Measurement

Mike Tovey, the founder and President of Tovey Engineering, has designed and built strain gage based transducers for the last 25 years. He is Chairman of ASTM Committee E28.01 for calibration of load cells and test machines and a Technical Expert in Force Calibration. He formerly served as President and Chief Engineer of Interface, Inc.

TOVEY ENGINEERING22602 N. 17th Avenue Phoenix, AZ 85027 623-434-5110 (fax) 623-434-5130 e-mail: [email protected]

Tovey Engineering is the Technical Leader in Load Cells and Force Measurement.

Call 623-434-5110 For Orders or Information.Or visit http://www.toveyengineering.com

Proprietary Shear Web, Shear Strain Technology for Maximum Performance

MTS Systems Corp. Award of Excellence for Outstanding Technical Contribution

Products Reflect Decades of Manufacturing Experience in High Performance Load Cells

Industry’s Most AccurateMetrology Grade Load Cells

Accuracy to .02% of Rated Capacity

Experts in High Accuracy Force and Torque Calibration Systems