TOSHIBAAIR
CONDITIONINGProduct Guide January 2017
01707 378 670 | ampair.co.uk
ampair.co.uk | 01707 378 670 | [email protected] 1
Cont
entsToshiba Air Conditioning Product Guide
Contents
About Us......................................................02 Indoor - Wall Mounted.......................... 130
Indoor - Ceiling Suspended.................. 134
RAS Split Systems....................................07 Indoor - Floor Standing.........................137
Range Overview.......................................08
Wall Mounted...........................................10 Air Handling & HRV..................................147
Bi Flow Floor Standing...........................17 Air to Air with DX Coil.............................148
Multi Splits - Outdoor Units................. 18 Fresh Air Intake Units............................ 150
Multi Splits - Indoor Units.....................20 VN Heat Recovery Ventilation Units.. 151
Multi Splits Combination Tables......... 23 VRF Air Handling Unit Interface...........154
RAV Air Handling Unit Interface.......... 156
RAV Split Systems.................................... 33
Range Overview.......................................35 Applied & Air to Water........................... 163
Wall Mounted...........................................36 CIAT............................................................164
Compact Cassette...................................40 Air Curtains - RAV....................................166
4 Way Cassette........................................43 Air Curtains - VRF....................................181
Slim Ducted..............................................49 Estia Air to Water....................................184
Standard Ducted.....................................52
High Static Ducted..................................58 Controls....................................................... 195
Ceiling Suspended..................................60
Floor Standing Conversions.................66 Toshiba Rewards......................................207
Twin, Triple & Quad Systems...............70
Reference/Faults......................................215
VRF.................................................................81
Outdoor - Overview................................83 Index.............................................................224
Outdoor - Mini SMMS Heat Pump......84
Outdoor - SMMSe Heat Pump............ 85
Outdoor - SHRMi Heat Recovery........ 95
Indoor - FSU Boxes & Branch Pipes.. 102
Indoor - Overview...................................103
Indoor - Heating/Cooling Capacities..104
Indoor - Cassettes................................... 106
Indoor - Ducted.......................................118
Where are we?
AMP are located in Welwyn Garden City, Hertfordshire only 20 miles from the M25 (Jct 23) and 3 miles from the A1(M) (Jct 6).
AMP Air Conditioning, Blenheim HouseBlenheim Court, BrownfieldsWelwyn Garden CityHerts AL7 1AD
@amp_aircon | amp-air-conditioning 2
Abou
t Us
We’ve come a long way since 1989 when we sold our first air conditioning unit from a small office in Edmonton, North London. Today we’re the UK’s largest independent distributor of HVAC products working from a comprehensive, purpose-built venue in Hertfordshire with multiple warehouse locations throughout the country. We’ve grown significantly over the years by keeping our focus on our customers ensuring we’re exceeding your expectations again and again. In an ever changing business environment, we know you rely on us to do everything we can to support you and your customers.
Since the start of 2015 we’ve invested in our company giving you the confidence that we’re the most qualified partner for all your air conditioning needs. Our team recently secured two internationally recognised independent accreditations for environmental and quality management. Our ISO 9001 and 14001 accreditations require us to follow clear, documented procedures for managing our business to consistently achieve high customer satisfaction and minimise environmental impact.
We also know it’s important for our staff to be trained to the highest levels and so we continue to invest in our staff through professional training and qualifications. Almost a quarter of AMP’s staff have completed NVQs in Customer Service and Management over the past year and we plan to continue this calendar of ongoing eduction moving forward.
About UsAn Introduction to AMP Air Conditioning
Martin MichaelsonCompany Director & Co-owner
Polly McConachieCompany Director & Co-owner
WE KNOW HOW MUCH YOU RELY ON US TO PROVIDE THE BEST SOLUTION
FOR YOU SO WE WORK HARD TO ENSURE THAT WE’RE UNRIVALLED
WHEN IT COMES TO CUSTOMER SERVICE AND SUPPORT.
ampair.co.uk | 01707 378 670 | [email protected] 3
Abou
t UsAbout Us
Customer Services
Warranty & After Sales Support
All products supplied by AMP are provided with a comprehensive three year warranty as standard, covering parts and a contribution towards fitting costs*. In the unlikely event that you encounter a problem with a Toshiba system, you can rest assured it will be resolved quickly and efficiently by our professional after sales team. Extended warranties are available through Toshiba Rewards - see page 207 for more information.
Industry Leading Technical Support
We offer an experienced and dedicated pre and post sales technical support team who have many years experience across all Toshiba product ranges. Their expertise encompasses answering the smallest query right through to designing and supporting complex VRF projects. We also have specialist engineers on call to help commission and fault find at a moment’s notice.
Design Services
At AMP we understand that selecting the right equipment for your project is of the utmost importance. With this in mind, our in-house design team is available to provide help with the design of all aspects of your project, whether it’s for a commercial or domestic environment. Our experienced team can review your requirements and apply the most suitable equipment from our portfolio to meet both your needs and budget.
Training
We believe in passing on knowledge and expertise to our customers. Our specially designed Toshiba training courses cover product selection, installation, maintenance and controls. We offer the opportunity of hands-on training giving your engineers the opportunity to experience working systems. Certificates and training guides are offered as part of each course for reference and proof of attendance.
Delivery
We pride ourselves on flexibility of service, offering next day delivery on all orders received up to 3pm the day before. With our main warehouse in Hertfordshire (just north of London) and benefiting from multiple warehouse storage facilities throughout the UK, we are ideally placed to serve the capital and the rest of the UK quickly and easily. For urgent orders, same day delivery may be available depending on stock availability and delivery location.
Additional services offered by AMP include Grille Colour Matching, Coil Coating, Bespoke Control Panels, VRF Strip-Down and On-site Engineer visits. Contact your local sales representative or call our customer services team for more information.
*Terms & Conditions apply.
Abou
t Us About Us
Customer Testimonials
FOR MORE THAN A DECADE, AMP HAVE
PROVIDED A SPECIALIST SALES ROUTE FOR
OUR PRODUCTS, AS WELL AS PROVIDING A
FULL PRE-SALES AND AFTER SALES SUPPORT FUNCTION ENSURING
OUR CUSTOMERS’ EXPECTATIONS ARE
MET OR EXCEEDED. IN THE LAST 12 MONTHS THEY HAVE FURTHER
DEVELOPED THEIR TEAM BY ADDING KEY CORE STRENGTHS TO
THEIR STAFF WITH CONTINUOUS TRAINING
AND ISO QUALIFICATION TO ENHANCE THE
CUSTOMERS EXPERIENCE.
“
”David DunnToshiba Air Conditioning
“AMP have been our one stop shop for all things air conditioning since 1989. Quotations, sales,
technical information, on site back up and on time delivery. AMP have delivered exceptional service on all levels at all times for the 27 years we have
worked together.”
Martin PerkinsR Perkins & Sons
“AMP has been a crucial supplier to Hawkes over the last 20 years. We know AMP delivers a first
class, professional, competitive and yet personal service to us at Hawkes. Truly an astonishing team
of hard working, genuine and knowledgeable people that we will continue to use for all of our air conditioning and heat recovery ventilation
requirements.”
BARRY HAWKESHawkes Refrigeration Engineers
“Being in such a fast-pace and reactive industry, it is important to us to have such a reliable and
efficient supplier like AMP. They really understand our needs and are willing to go the extra mile for us. For a number of years they have continued
to provide us with good quality service and products.”
DAVID CHAPMANChapman Ventilation
@amp_aircon | amp-air-conditioning 4
About UsSub-Title
“AMP are a pleasure to deal with, very nice people who are always happy to help. AMP are very prompt and fair for the sometimes difficult but very important after-sales service”Damian Nunn - Pitkin & Ruddock Ltd
Photo: Steve O’Brien, Warehouse Operative at AMP
Abou
t Us
ampair.co.uk | 01707 378 670 | [email protected] 5ampair.co.uk | 01707 378 670 | [email protected] 5
Abou
t Us About Us
Toshiba Rewards
@amp_aircon | amp-air-conditioning 6
Toshiba’s New Incentive Scheme
Toshiba Rewards is the new incentive scheme from Toshiba. Launched in January 2016 it builds on the success of the Additions scheme to further reward installers of Toshiba Air Conditioning products.
Reward points are awarded on every purchase of Toshiba products through AMP, these points can then be exchanged for a variety of diff erent rewards.
In addition, simply by registering you will be eligible for an enhanced 5 year warranty, this can be further extended to 7 years, subject to meeting certain criteria.
Exchange rewards points for…
» Love2Shop gift cards» European and Worldwide holidays with Love2Travel» Toshiba air conditioning units and accessories» Trade installation products
» Marketing support
To Qualify
» No minimum turnover» One application per company» Contractor must adhere to F-Gas» Contractor must be Refcom or equivalent compliant» Points accumulated on paid invoices» Please speak to your sales person who will be happy to assist with your registration details.
See page 207 for further
scheme details
ampair.co.uk | 01707 378 670 | [email protected] 7ampair.co.uk | 01707 378 670 | [email protected] 7
RAS Split Systems
RAS
Resi
dent
ial
@amp_aircon | amp-air-conditioning 8
RAS
Resi
dent
ial
RAS ResidentialIntroduction & Range Overview
Single Split Systems
The Mirai, AvAnt & Daiseikai range of inverter high-wall units has been specifi cally designed for residential applications. The modern design fi ts well into any room. The units are extremely quiet in operation, provide excellent all round comfort and give high energy effi cient heating and cooling. The Mirai range are available in both R410A and R32 at no extra cost. In addition a range of fl oor standing split systems are also available.
Multi Split Systems
When it is necessary to provide a total comfort solution for a multi-room application, Toshiba multi split systems off er the perfect answer for any kind of requirement. One outdoor unit is capable of operating 2, 3, 4 or 5 indoor units. They are compact and elegant as they are designed to blend in with any room interior. In fact, Toshiba off ers a wide range of possibilities to create all the comfort you desire.
Single Split Systems
Nominal Cooling
1.5 2.0 2.5 3.1 3.5 4.5 5.0
Mirai R410A Wall Mounted 1Ph (10) 1Ph (10) 1Ph (11) 1Ph (11)
Mirai R32 Wall Mounted 1Ph (12) 1Ph (12) 1Ph (12) 1Ph (13) 1Ph (13)
AvAnt Wall Mounted 1Ph (14) 1Ph (14) 1Ph (14)
Daiseikai Wall Mounts
1Ph (15 - 16)
1Ph (15 - 16)
1Ph (15 - 16)
Bi Flow Floor Standing 1Ph (17) 1Ph (17) 1Ph (17)
ampair.co.uk | 01707 378 670 | [email protected] 9
RAS
Resi
dent
ial
RAS ResidentialRange Overview
Multi Split Outdoor Units
Number Of Indoors - Nominal Cooling
2 - 4.0 2 - 5.2 3 - 5.2 3 - 7.5 4 - 8.0 5 -10.0
1Ph (18) 1Ph (18) 1Ph (18) 1Ph (19) 1Ph (19) 1Ph (19)
Page numbers in brackets.
Multi Split Indoors
Nominal Cooling
2.5 3.5 4.5 5.0
Daiseikai Wall Mounts 1Ph (20) 1Ph (20) 1Ph (20)
Wall Mounted 1Ph (20) 1Ph (20) 1Ph (20)
Bi Flow Floor Standing 1Ph (21) 1Ph (21) 1Ph (21)
CompactCassette 1Ph (21) 1Ph (21) 1Ph (21)
Ducted 1Ph (22) 1Ph (22) 1Ph (22)
Page numbers in brackets.
@amp_aircon | amp-air-conditioning 10
RAS
Resi
dent
ial
RAS ResidentialMirai Wall Mounted
Indoor Unit RAS-07BKV-E RAS-10BKV-E
Infrared Remote Controller Included Included
Outdoor Unit RAS-07BAV-E RAS-10BAV-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 2.00 (0.65 - 2.50) 2.50 (0.67 - 3.10)
UK Cooling (Total - Sensible) kW 1.47 - 1.22 1.95 - 1.68
Nominal Heating (Range) kW 2.50 (0.55 - 3.20) 3.20 (0.70 - 3.90)
UK Heating kW TBC TBC
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.70 - 4.00 5.60 - 4.00
Energy Efficiency Class (Cool / Heat) A+ / A+ A+ / A+
EER - COP (Cool - Heat) 3.33 - 4.03 2.94 - 3.81
Energy Label (Cool / Heat) TBC TBC
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 24°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 293 - 798 - 230 293 - 798 - 230
Outdoor Unit Dimensions (H-W-D) mm 530 - 660 - 240 530 - 660 - 240
Weight (Indoor - Outdoor) kg 9.0 - 21.0 9.0 - 21.0
AIRF
LOW
Indoor Unit Airflow Rate (l-h) l/s 68 - 148 70 - 153
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-h) dB(A) 22 - 40 23 - 41
Outdoor Sound Pressure (cool-heat) dB(A) 48 - 50 48 - 50
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 15 - 12 15 - 12
Pre-charged for m 15 15
Charge R410A (Factory - Additional) kg 0.48 - n/a 0.52 - n/a
Suitable for Replacement Tech. Yes (3/8” - 1/4” only) Yes (3/8” - 1/4” only)
Indoor Drain Connection mm 16 16
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 3.10 - 3.17 4.22 - 4.21
Power Consumption (Cool - Heat) kW 0.60 - 0.62 0.85 - 0.84
Suggested Fuse Size A 10 10
Indoor Unit £166 £169
Outdoor Unit £391 £399
Retail Price £557 £568Gravity drain | Rear, top, left or right piping. | For control via GSM or SMS use the Intesis Wi Fi option, see page 201 for details |RB-RXS30-E Controller with weekly timer £54
Specialprice offersavailable on
Mirai systemsContact us for
details
R410A
ampair.co.uk | 01707 378 670 | [email protected] 11
RAS
Resi
dent
ial
RAS ResidentialMirai Wall Mounted
Indoor Unit RAS-13BKV-E RAS-16BKV-E
Infrared Remote Controller Included Included
Outdoor Unit RAS-13BAV-E RAS-16BAV-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 3.10 (0.75 - 3.50) 4.40 (1.10 - 4.80)
UK Cooling (Total - Sensible) kW 2.44 - 2.03 3.03 - 2.44
Nominal Heating (Range) kW 3.60 (0.70 - 4.50) 5.20 (0.80 - 6.10)
UK Heating kW TBC TBC
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.70 - 4.00 5.90 - 4.20
Energy Efficiency Class (Cool / Heat) A+ / A+ A+ / A+
EER - COP (Cool - Heat) 2.70 - 3.75 2.82 - 3.42
Energy Label (Cool / Heat) TBC TBC
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 24°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 293 - 798 - 230 293 - 798 - 230
Outdoor Unit Dimensions (H-W-D) mm 530 - 660 - 240 530 - 780 - 240
Weight (Indoor - Outdoor) kg 9.0 - 22.0 10.0 - 34.0
AIRF
LOW
Indoor Unit Airflow Rate (l-h) l/s 82 - 172 97 - 210
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-h) dB(A) 24 - 42 26 - 43
Outdoor Sound Pressure (cool-heat) dB(A) 48 - 50 49 - 50
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 15 - 12 20 - 12
Pre-charged for m 15 15
Charge R410A (Factory - Additional) kg 0.58 - n/a 0.96 - 20g/m
Suitable for Replacement Tech. Yes (3/8” - 1/4” only) Yes (1/2” - 1/4” only)
Indoor Drain Connection mm 16 16
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 5.60 - 4.75 7.55 - 7.38
Power Consumption (Cool - Heat) kW 1.15 - 0.96 1.56 - 1.52
Suggested Fuse Size A 10 16
Indoor Unit £174 £211
Outdoor Unit £458 £662
Retail Price £632 £873Gravity drain | Rear, top, left or right piping. | For control via GSM or SMS use the Intesis Wi Fi option, see page 201for details |RB-RXS30-E Controller with weekly timer £54
Specialprice offersavailable on
Mirai systemsContact us for
details
R410A
@amp_aircon | amp-air-conditioning 12
RAS
Resi
dent
ial
RAS ResidentialMirai Wall Mounted
Indoor Unit RAS-05BKVG-E RAS-07BKVG-E RAS-10BKVG-E
Infrared Remote Controller Included Included Included
Outdoor Unit RAS-05BAVG-E RAS-07BAVG-E RAS-10BAVG-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 1.50 (0.66 - 2.00) 2.00 (0.67 - 2.60) 2.50 (0.68 - 3.00)
UK Cooling (Total - Sensible) kW 1.47 - 1.22 1.95 - 1.57 2.44 - 1.93
Nominal Heating (Range) kW 2.00 (0.54 - 3.00) 2.50 (0.55 - 3.30) 3.20 (0.71 - 3.90)
UK Heating kW TBC TBC TBC
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.60 - 4.00 5.60 - 4.00 5.70 - 4.00
Energy Efficiency Class (Cool / Heat) A+ / A+ A+ / A+ A+ / A+
EER - COP (Cool - Heat) 3.85 - 4.26 3.45 - 3.91 3.25 - 3.76
Energy Label (Cool / Heat) TBC TBC TBC
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 24°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 293 - 798 - 230 293 - 798 - 230 293 - 798 - 230
Outdoor Unit Dimensions (H-W-D) mm 530 - 660 - 240 530 - 660 - 240 530 - 660 - 240
Weight (Indoor - Outdoor) kg 9.0 - 21.0 9.0 - 21.0 9.0 - 21.0
AIRF
LOW
Indoor Unit Airflow Rate (l-h) l/s 68 - 145 68 - 148 70 - 153
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-h) dB(A) 22 - 37 23 - 38 24 - 39
Outdoor Sound Pressure (cool-heat) dB(A) 48 - 50 48 - 50 49 - 51
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4" 3/8" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 15 - 12 15 - 12 15 - 12
Pre-charged for m 15 15 15
Charge R32 (Factory - Additional) kg 0.40- n/a 0.40 - n/a 0.43 - n/a
Suitable for Replacement Tech. No No No
Indoor Drain Connection mm 16 16 16
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 2.02 - 2.40 2.95 - 3.25 3.85 - 3.17
Power Consumption (Cool - Heat) kW 0.39 - 0.47 0.58 - 0.64 0.77 - 0.85
Suggested Fuse Size A 10 10 10
Indoor Unit £158 £166 £169
Outdoor Unit £372 £391 £399
Retail Price £530 £557 £568Gravity drain | Rear, top, left or right piping. | For control via GSM or SMS use the Intesis Wi Fi option, see page 201 for details |RB-RXS30-E Controller with weekly timer £54
R32
ampair.co.uk | 01707 378 670 | [email protected] 13
RAS
Resi
dent
ial
RAS ResidentialMirai Wall Mounted
Indoor Unit RAS-13BKVG-E RAS-16BKVG-E
Infrared Remote Controller Included Included
Outdoor Unit RAS-13BAVG-E RAS-16BAVG-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 3.30 (0.75 - 3.0) 4.60 (1.20 - 5.30)
UK Cooling (Total - Sensible) kW 3.22 - 2.49 4.49 - 3.36
Nominal Heating (Range) kW 3.60 (0.72 - 4.50) 5.40 (0.93 - 6.40)
UK Heating kW TBC TBC
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.60 - 4.00 6.20 - 4.20
Energy Efficiency Class (Cool / Heat) A+ / A+ A++ / A+
EER - COP (Cool - Heat) 2.92 - 3.75 3.01 - 3.48
Energy Label (Cool / Heat) TBC TBC
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 24°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 293 - 798 - 230 293 - 798 - 230
Outdoor Unit Dimensions (H-W-D) mm 530 - 660 - 240 530 - 780 - 240
Weight (Indoor - Outdoor) kg 9.0 - 22.0 10.0 - 34.0
AIRF
LOW
Indoor Unit Airflow Rate (l-h) l/s 82 - 172 97 - 213
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-h) dB(A) 24 - 42 25 - 43
Outdoor Sound Pressure (cool-heat) dB(A) 50 - 51 50 - 52
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 15 - 12 20 - 12
Pre-charged for m 15 15
Charge R32 (Factory - Additional) kg 0.43 - n/a 0.80 - TBC
Suitable for Replacement Tech. No No
Indoor Drain Connection mm 16 16
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 5.48 - 4.65 7.19 - 7.17
Power Consumption (Cool - Heat) kW 1.13 - 0.96 1.53 - 1.55
Suggested Fuse Size A 10 16
Indoor Unit £174 £211
Outdoor Unit £458 £662
Retail Price £632 £873Gravity drain | Rear, top, left or right piping. | For control via GSM or SMS use the Intesis Wi Fi option, see page 201 for details |RB-RXS30-E Controller with weekly timer £54
R32
@amp_aircon | amp-air-conditioning 14
RAS
Resi
dent
ial
RAS ResidentialAvAnt Wall Mounted
Indoor Unit RAS-107SKV-E7 RAS-167SKV-E7
Infrared Remote Controller Included Included
Outdoor Unit RAS-107SAV-E6 RAS-167SAV-E5
PERF
ORM
ANCE
Nominal Cooling (Range) kW 2.5 (1.2 - 3.0) 4.4 (1.1 - 5.0)
UK Cooling (Total - Sensible) kW 2.44 - 2.16 4.30 - 3.37
Nominal Heating (Range) kW 3.2 (0.9 - 3.5) 5.2 (1.0 - 6.2)
UK Heating kW 2.05 3.34
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.1 - 3.8 5.8 - 3.8
Energy Effi ciency Class (Cool / Heat) A / A A+ / A
EER - COP (Cool - Heat) 3.25 - 3.81 2.82 - 3.42
Energy Label (Cool / Heat) A / A C / B
AMBI
ENT
RAN
GE Cooling °C 46°C to -10°C
Heating °C 24°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 275 - 790 - 205 275 - 790 - 205
Outdoor Unit Dimensions (H-W-D) mm 530 - 660 - 240 550 - 780 - 290
Weight (Indoor - Outdoor) kg 9 - 28 9 - 40
AIRF
LOW
Indoor Unit Airfl ow Rate (l-h) l/s 70 - 158 103 - 207
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-h) dB(A) 28 - 41 31 - 45
Outdoor Sound Pressure (cool-heat) dB(A) 48 - 50 49 - 50
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff .) m 15 - 8 20 - 10
Pre-charged for m 15 15
Charge R410A (Factory - Additional) kg 0.63 - n/a 1.05 - 20g/m
Suitable for Replacement Tech. No No
Indoor Drain Connection mm VP16 (14id 16od) VP16 (14id 16od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 3.88 - 4.19 7.13 - 6.91
Power Consumption (Cool - Heat) kW 0.77 - 0.84 1.53 - 1.53
Suggested Fuse Size A 10 16
Indoor Unit £179 £222
Outdoor Unit £421 £697
Retail Price £600 £919
Gravity drain | Rear, top, left or right piping | Auto restart | Infrared control only, no hard-wired option |RB-RXS30-E Controller with weekly timer £54.
WhileStocks
Last
ampair.co.uk | 01707 378 670 | [email protected] 15
RAS
Resi
dent
ial
RAS ResidentialDaiseikai 6 Wall Mounted
Indoor Unit RAS-B10N3KVP-E RAS-B13N3KVP-E RAS-B16N3KVP-E
Infrared Remote Controller Included Included Included
Outdoor Unit RAS-10N3AVP-E RAS-13N3AVP-E RAS-16N3AVP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 2.51 (0.80 - 3.50) 3.52 (0.90 - 4.10) 4.53 (0.90 - 5.00)
UK Cooling (Total - Sensible) kW 2.39 - 2.07 3.35 - 2.77 4.31 - 3.37
Nominal Heating (Range) kW 3.21 (0.80 - 5.80) 4.22 (0.80 - 5.90) 5.53 (0.80 - 6.70)
UK Heating kW 2.06 2.70 3.54
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 8.50 - 4.60 7.00 - 4.50 6.60 - 4.30
Energy Efficiency Class (Cool / Heat) A+++ / A++ A++ / A+ A++ / A+
EER - COP (Cool - Heat) 5.12 - 4.60 4.19 - 4.44 3.38 - 3.76
Energy Label (Cool / Heat) A / A A / A A / A
AMBI
ENT
RAN
GE Cooling °C 46°C to -10°C
Heating °C 24°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 275 - 790 - 225 275 - 790 - 225 275 - 790 - 225
Outdoor Unit Dimensions (H-W-D) mm 630 - 800 - 300 630 - 800 - 300 630 - 800 - 300
Weight (Indoor - Outdoor) kg 10 - 41 10 - 41 10 - 41
AIRF
LOW
Indoor Unit Airflow Rate (l-h) l/s 175 - 197 183 - 210 192 - 210
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-h) dB(A) 27 - 43 27 - 44 27 - 45
Outdoor Sound Pressure (cool-heat) dB(A) 46 - 47 48 - 50 49 - 50
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 25 - 10 25 - 10 25 - 10
Pre-charged for m 15 15 15
Charge R410A (Factory - Additional) kg 1.05 - 20g/m 1.05 - 20g/m 1.05 - 20g/m
Suitable for Replacement Tech. no no no
Indoor Drain Connection mm VP16 (14id 16od) VP16 (14id 16od) VP16 (14id 16od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 2.94 4.30 6.13
Power Consumption (Cool - Heat) kW 0.49 - 0.63 0.84 - 0.95 1.34 - 1.47
Suggested Fuse Size A 10 10 16
Indoor Unit £303 £312 £334
Outdoor Unit £933 £989 £1,239
Retail Price £1,236 £1,301 £1,573
Gravity drain | Rear, top, left or right piping | Auto restart | Infrared control only, no hard-wired option.
@amp_aircon | amp-air-conditioning 16
RAS
Resi
dent
ial
RAS ResidentialDaiseikai 8 Wall Mounted
Indoor Unit RAS-10G2KVP-E RAS-13G2KVP-E RAS-16G2KVP-E
Infrared Remote Controller Included Included Included
Outdoor Unit RAS-10G2AVP-E RAS-13G2AVP-E RAS-16G2AVP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 2.50 (0.55 - 3.50) 3.50 (0.63 - 4.10) 4.50 (0.63 - 5.00)
UK Cooling (Total - Sensible) kW 2.44 - 2.27 3.42 - 2.89 4.40 - 3.36
Nominal Heating (Range) kW 3.20 (0.45 - 5.80) 4.00 (0.65 - 6.30) 5.50 (0.65 - 6.80)
UK Heating kW 2.05 2.56 3.52
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 9.10 - 5.20 8.90 - 5.10 7.30 - 4.60
Energy Effi ciency Class (Cool / Heat) A+++ / A+++ A+++ / A+++ A++ / A++
EER - COP (Cool - Heat) 5.15 - 5.52 4.27 - 5.00 3.46 - 4.01
Energy Label (Cool / Heat) A / A A / A A / A
AMBI
ENT
RAN
GE Cooling °C 46°C to -10°C
Heating °C 24°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 293 - 831 - 270 293 - 831 - 270 293 - 831 - 270
Outdoor Unit Dimensions (H-W-D) mm 630 - 800 - 300 630 - 800 - 300 630 - 800 - 300
Weight (Indoor - Outdoor) kg 14 - 42 14 - 42 14 - 42
AIRF
LOW
Indoor Unit Airfl ow Rate l/s 180 187 193
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-h) dB(A) 20 - 42 21 - 43 23 - 44
Outdoor Sound Pressure (cool-heat) dB(A) 47 49 50
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff .) m 25 - 10 25 - 10 25 - 10
Pre-charged for m 15 15 15
Charge R410A (Factory - Additional) kg 1.05 - 20g/m 1.05 - 20g/m 1.05 - 20g/m
Suitable for Replacement Tech. no no no
Indoor Drain Connection mm VP16 (14id 16od) VP16 (14id 16od) VP16 (14id 16od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 2.52 3.57 5.96
Power Consumption (Cool - Heat) kW 0.48 - 0.58 0.82 - 0.80 1.30 - 1.37
Suggested Fuse Size A 10 10 16
Indoor Unit £397 £407 £425
Outdoor Unit £903 £959 £1,226
Retail Price £1,300 £1,366 £1,651
Gravity drain | Rear, top, left or right piping | Auto restart | Infrared control only, no hard-wired option.
ampair.co.uk | 01707 378 670 | [email protected] 17
RAS
Resi
dent
ial
RAS ResidentialBi Flow Floor Standing
Indoor Unit RAS-B10UFV-E1 RAS-B13UFV-E1 RAS-B18UFV-E1
Infrared Remote Controller Included Included Included
Outdoor Unit RAS-10N3AV2-E1 RAS-13N3AV2-E1 RAS-18N3AV2-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 2.5 (1.10 - 3.10) 3.5 (1.10 - 4.10) 5.0 (1.00 - 5.70)
UK Cooling (Total - Sensible) kW 2.44 - 2.03 3.42 - 2.74 4.89 - 3.77
Nominal Heating (Range) kW 3.2 (0.90 - 4.80) 4.2 (1.00 - 5.00) 5.8 (1.10 - 6.30)
UK Heating kW 2.05 2.69 3.72
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 6.60 - 4.10 6.30 - 4.00 5.70 - 3.80
Energy Effi ciency Class (Cool / Heat) A++ / A+ A++ / A A+ / A
EER - COP (Cool - Heat) 4.20 - 4.27 3.33 - 3.36 3.01 - 3.21
Energy Label (Cool / Heat) A / A A / A B / C
AMBI
ENT
RAN
GE Cooling °C 46°C to -10°C
Heating °C 24°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 600 - 700 - 220 600 - 700 - 220 600 - 700 - 220
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 16 - 33 16 - 34 16 - 39
AIRF
LOW
Indoor Unit Airfl ow Rate (l-h) l/s 75 - 142 80 - 153 102 - 18
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/ a n/a n/a
SOU
ND Indoor Sound Pressure (l-h) dB(A) 26 - 39 27 - 40 34 - 46
Outdoor Sound Pressure (cool-heat) dB(A) 46 - 47 48 - 50 49 - 50
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff .) m 20 - 10 20 - 10 20 - 10
Pre-charged for m 15 15 15
Charge R410A (Factory - Additional) kg 0.80 - 20g/m 0.80 - 20g/m 1.40 - 20g/m
Suitable for Replacement Tech. no no no
Indoor Drain Connection mm VP16 (14id 16od) VP16 (14id 16od) VP16 (14id 16od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 2.90 - 3.51 4.52 - 5.18 7.54 - 8.19
Power Consumption (Cool - Heat) kW 0.60 - 0.75 1.05 - 1.25 1.66 - 1.81
Suggested Fuse Size A 10 10 16
Indoor Unit £537 £585 £648
Outdoor Unit £518 £642 £823
Retail Price £1,055 £1,227 £1,471
Gravity drain | Auto restart | Infrared control only, no hard-wired option.Gravity drain | Auto restart | Infrared control only, no hard-wired option.
@amp_aircon | amp-air-conditioning 18
RAS
Resi
dent
ial
RAS ResidentialMulti Split Outdoor Units
Outdoor Unit Model Number RAS-2M14S3AV-E RAS-2M18S3AV-E RAS-3M18S3AV-E
Nominal Cooling (Range) kW 4.0 (1.6 - 4.9) 5.2 (1.7 - 6.2) 5.2 (2.4 - 6.5)
Nominal Heating (Range) KW 4.4 (1.3 - 5.2) 5.6 (1.3 - 7.5) 6.8 (1.9 - 8.0)
Number Of Indoor Units 2 2 2 - 3
EFF.
EER - COP (Cool - Heat) 4.82 - 5.18 3.88 - 4.71 4.44 - 4.30
Energy Efficiency Class (Cool / Heat) TBC TBC TBC
AMBI
ENT
RAN
GE Cooling °C -10°C to 46°C -10°C to 46°C -10°C to 46°C
Heating °C -20°C to 24°C -20°C to 24°C -20°C to 24°C
PHYS
ICAL
Height mm 630 630 630
Width mm 800 800 800
Depth mm 300 300 300
Weight kg 44 44 46
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool-Heat) dB(A) 45 - 46 47 - 50 47 - 50
Airflow Rate l/s 517 585 605
Max External Static Pressure Pa 0 0 0
REFR
IGER
ANT
& P
IPEW
ORK
Gas Pipe Size* in 3/8" 3/8" 1/2" (A) 3/8" (B-C)
Liquid Pipe Size* in 1/4” 1/4” 1/4”
Maximum Pipe Run (Per Unit) m 20 20 25
Maximum Pipe Run (Total) m 30 30 50
Maximum Height Difference m 10 10 10
Pre-charged for m 10 10 15
Charge R410A - Factory Kg 1.32 1.32 1.50
Charge R410A - Additional g/m TBC TBC TBC
Suitable For Replacement Tech. No No No
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 16 16 16
Power Input (Cool - Heat) kW 0.93 - 0.89 1.34 - 1.19 1.17 - 1.58
Running Current (Cool - Heat) A 3.87 - 3.96 6.15 - 5.48 5.39 - 7.22
Max Current A 12.6 12.6 13.1
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Outdoor Unit £843 £927 £1,314
Retail Price £843 £927 £1,314
* Pipework size to be as per indoor unit | For performance data when each indoor unit is combined with outdoor unit refer to separate table.
ampair.co.uk | 01707 378 670 | [email protected] 19
RAS
Resi
dent
ial
RAS ResidentialMulti Split Outdoor Units
Outdoor Unit Model Number RAS-3M26S3AV-E RAS-4M27S3AV-E RAS-5M34S3AV-E
Nominal Cooling (Range) kW 7.5 (4.1 - 9.0) 8.0 (4.2 - 9.3) 10.0 (3.7 - 11.0)
Nominal Heating (Range) KW 9.0 (2.0 - 11.2) 9.0 (2.9 - 11.7) 12.0 (2.7 - 14.0)
Number Of Indoor Units 2 - 3 2 - 4 2 - 5
EFF.
EER - COP (Cool - Heat) 3.75 - 4.09 3.50 - 4.67 3.36 - 4.24
Energy Efficiency Class (Cool / Heat) TBC TBC TBC
AMBI
ENT
RAN
GE Cooling °C -10°C to 46°C -10°C to 46°C -10°C to 46°C
Heating °C -15°C to 24°C -15°C to 24°C -15°C to 24°C
PHYS
ICAL
Height mm 890 890 890
Width mm 900 900 900
Depth mm 320 320 320
Weight kg 72 69 78
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool-Heat) dB(A) TBC 48 - 49 TBC
Airflow Rate l/s 696 696 1018
Max External Static Pressure Pa 0 0 0
REFR
IGER
ANT
& P
IPEW
ORK
Gas Pipe Size* in 1/2" (A-B) 3/8" (C) 1/2" (A&B) 3/8" (C&D) 1/2" (A&B) 3/8" (C-E)
Liquid Pipe Size* in 1/4” 1/4” 1/4”
Maximum Pipe Run (Per Unit) m 25 25 25
Maximum Pipe Run (Total) m 70 70 80
Maximum Height Difference m 15 15 15
Pre-charged for m 40 40 40
Charge R410A - Factory Kg 2.40 2.40 2.99
Charge R410A - Additional g/m 20 20 20
Suitable For Replacement Tech. No No No
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A TBC 20 TBC
Power Input (Cool - Heat) kW 2.00 - 2.20 2.29 - 1.93 2.98 - 2.83
Running Current (Cool - Heat) A 9.15 - 10.07 10.46 - 8.82 13.65 - 12.97
Max Current A TBC 16.4 TBC
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Outdoor Unit £1,550 £1,892 £2,154
Retail Price £1,550 £1,892 £2,154
* Pipework size to be as per indoor unit | For performance data when each indoor unit is combined with outdoor unit refer to separate table.
@amp_aircon | amp-air-conditioning 20
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Indoors
Daiseikai Multi Split High Wall
Indoor Unit inc. Infrared Controller RAS-B10N3KVP-E RAS-B13N3KVP-E RAS-B16N3KVP-E
Nominal Cooling kW 2.5 3.5 4.5
Nominal Heating kW 3.2 4.2 5.2
Indoor Unit Dimensions (h-w-d) mm 275 - 790 - 225 275 - 790 - 225 275 - 790 - 225
Indoor Weight kg 10 10 10
Indoor Unit Airfl ow Rate (Cool - Heat) l/s 175 - 194 183 - 203 192 - 208
Indoor Sound Pressure (l-h) dB(A) 27 - 42 27 - 43 29 - 45
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
Power Supply (Location) Outdoor Outdoor Outdoor
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Indoor Unit £303 £312 £334
Grille / Spigot Kit n/a n/a n/a
Infra Red Remote Controller Included Included Included
Retail Price £303 £312 £334
Gravity drain | Rear, top, left or right piping | Cooling/heating capacities depend on unit combinations & outdoor unit.
Multi Split High Wall
Indoor Unit inc. Infrared Controller RAS-B10N3KV2-E1 RAS-B13N3KV2-E1 RAS-B16N3KV2-E1
Nominal Cooling kW 2.5 3.5 4.5
Nominal Heating kW 3.2 4.2 5.2
Indoor Unit Dimensions (h-w-d) mm 275 - 790 - 225 275 - 790 - 225 275 - 790 - 225
Indoor Weight kg 10 10 10
Indoor Unit Airfl ow Rate (Cool - Heat) l/s 143 - 158 156 - 175 190 - 206
Indoor Sound Pressure (l-h) dB(A) 26 - 38 26 - 39 30 - 45
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
Power Supply (Location) Outdoor Outdoor Outdoor
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Indoor Unit £266 £280 £312
Grille / Spigot Kit n/a n/a n/a
Infra Red Remote Controller Included Included Included
Retail Price £266 £280 £312
Gravity drain | Rear, top, left or right piping | Cooling/heating capacities depend on unit combinations & outdoor unit.
ampair.co.uk | 01707 378 670 | [email protected] 21
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Indoors
Multi Split Bi Flow Console
Indoor Unit inc. Infrared Controller RAS-B10UFV-E1 RAS-B13UFV-E1 RAS-B18UFV-E1
Nominal Cooling kW 2.5 3.5 5.0
Nominal Heating kW 3.2 4.2 5.8
Indoor Unit Dimensions (h-w-d) mm 600 - 700 - 220 600 - 700 - 220 600 - 700 - 220
Indoor Weight kg 16 16 16
Indoor Unit Airflow Rate (Cool - Heat) l/s 130 - 142 142 - 153 167 - 178
Indoor Sound Pressure (l-h) dB(A) 23 - 39 24 - 40 31 - 46
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
Power Supply (Location) Outdoor Outdoor Outdoor
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Indoor Unit £537 £585 £648
Grille / Spigot Kit n/a n/a n/a
Infra Red Remote Controller Included Included Included
Retail Price £537 £585 £648
Cooling/heating capacities depend on unit combinations & outdoor unit.
Multi Split 600mm2 Compact Cassette
Indoor Unit inc. Infrared Controller RAS-M10SMUV-E RAS-M13SMUV-E RAS-M16SMUV-E
Grille / Spigot Kit RB-B11MC(W)E RB-B11MC(W)E RB-B11MC(W)E
Nominal Cooling kW 2.7 3.7 4.5
Nominal Heating kW 4.0 5.0 5.2
Indoor Unit Dimensions (h-w-d) mm 268 (27) - 575 (700) -575 (700)
268 (27) - 575 (700) -575 (700)
268 (27) - 575 (700) -575 (700)
Indoor Weight kg 15 (3) 15 (3) 15 (3)
Indoor Unit Airflow Rate (Cool - Heat) l/s 120 - 152 120 - 172 125 - 183
Indoor Sound Pressure (l-h) dB(A) 30 - 37 30 - 38 31 - 40
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
Power Supply (Location) outdoor outdoor outdoor
Interconnecting Cable 3 core + E 3 core + E 3 core + E
Indoor Unit £679 £737 £782
Grille / Spigot Kit £216 £216 £216
Infra Red Remote Controller included included included
Retail Price £895 £953 £998
Cooling/heating capacities depend on unit combinations & outdoor unit.
@amp_aircon | amp-air-conditioning 22
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Indoors
Multi Split Ducted Indoor Units
Indoor Unit inc. Infrared Controller RAS-M10G3DV-E RAS-M13G3DV-E RAS-M16G3DV-E
Grille / Spigot Kit n/a n/a n/a
Nominal Cooling kW 2.7 3.7 4.5
Nominal Heating kW 4.0 5.0 5.5
Indoor Unit Dimensions (h-w-d) mm 210 - 700 - 450 210 - 700 - 450 210 - 900 - 450
Indoor Weight kg 16 16 19
Indoor Unit Airflow Rate (Low - High) l/s 106 - 158 107 - 169 117 - 217
Static Pressure Pa 35 35 35
Indoor Sound Pressure (l-h) dB(A) 27 - 35 27 - 37 24 - 35
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4"
Power Supply (Location) Outdoor Outdoor Outdoor
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Indoor Unit £782 £792 £844
Grille / Spigot Kit n/a n/a n/a
Infra Red Remote Controller Included Included Included
Retail Price £782 £792 £844Unit does not come with return air filter
ampair.co.uk | 01707 378 670 | [email protected] 23
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Combination Tables
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)
Supply Status A B A B A B
RAS-
2M14
S3A
V-E
230V
1 unit
7 - 2.00 - 2.00 -
10 - 2.70 - 4.00 -
13 - 3.70 - 4.40 -
2 units
7 7 2.00 2.00 2.20 2.20
10 7 2.30 1.70 2.63 1.77
13 7 2.60 1.40 2.73 1.67
10 10 2.00 2.00 2.00 2.00
13 10 2.31 1.69 2.30 2.10
13 13 2.00 2.00 2.20 2.20
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)
Supply Status A B A B A B
RAS-
2M18
S3A
V-E
230V
1 unit
7 - 2.00 - 2.70 -
10 - 2.70 - 4.00 -
13 - 3.70 - 5.00 -
16 - 4.50 - 5.50 -
2 units
7 7 2.00 2.00 2.70 2.70
10 7 2.70 2.00 3.34 2.26
13 7 3.38 1.82 3.64 1.96
16 7 3.60 1.60 3.76 1.84
10 10 2.60 2.60 2.80 2.80
13 10 3.01 2.19 3.11 2.49
16 10 3.25 1.95 3.24 2.36
13 13 2.60 2.60 2.80 2.80
16 13 2.85 2.35 2.93 2.67
16 16 2.60 2.60 2.80 2.80
@amp_aircon | amp-air-conditioning 24
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Combination Tables
RAS-
3M18
S3A
V-E
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)
Supply Status A B C A B C A B C
230V
1 unit
7 - - 2.00 - - 2.70 - -
10 - - 2.70 - - 4.00 - -
13 - - 3.70 - - 5.00 - -
16 - - 4.50 - - 5.50 - -
2 units
7 7 - 2.00 2.00 - 2.70 2.70 -
10 7 - 2.70 2.00 - 4.00 2.70 -
13 7 - 3.38 1.82 - 4.42 2.38 -
16 7 - 3.60 1.60 - 4.56 2.24 -
10 10 - 2.60 2.60 - 3.40 3.40 -
13 10 - 3.01 2.19 - 3.78 3.02 -
16 10 - 3.25 1.95 - 3.94 2.86 -
13 13 - 2.60 2.60 - 3.40 3.40 -
16 13 - 2.85 2.35 - 3.56 3.24 -
16 16 - 2.60 2.60 - 3.40 3.40 -
3 units
7 7 7 1.74 1.73 1.73 2.26 2.27 2.27
10 7 7 2.10 1.55 1.55 2.90 1.95 1.95
13 7 7 2.50 1.35 1.35 3.26 1.77 1.77
16 7 7 2.76 1.22 1.22 3.44 1.68 1.68
10 10 7 1.90 1.90 1.40 2.54 2.54 1.72
13 10 7 2.29 1.67 1.24 2.91 2.32 1.57
16 10 7 2.54 1.53 1.13 3.07 2.23 1.50
13 13 7 2.05 2.05 1.10 2.68 2.68 1.44
16 13 7 2.29 1.89 1.02 2.83 2.58 1.39
10 10 10 1.74 1.73 1.73 2.26 2.27 2.27
13 10 10 2.12 1.54 1.54 2.62 2.09 2.09
16 10 10 2.36 1.42 1.42 2.78 2.01 2.01
13 13 10 1.90 1.90 1.40 2.43 2.43 1.94
ampair.co.uk | 01707 378 670 | [email protected] 25
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Combination Tables
RAS-
3M26
S3A
V-E
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)
Supply Status A B C A B C A B C
230V
1 unit
7 - - 2.00 - - 2.70 - -
10 - - 2.70 - - 4.00 - -
13 - - 3.70 - - 5.00 - -
16 - - 4.50 - - 5.50 - -
18 - - 5.00 - - 6.00 - -
2 units
7 7 - 2.00 2.00 - 2.70 2.70 -
10 7 - 2.70 2.00 - 4.00 2.70 -
13 7 - 3.70 2.00 - 4.81 2.59 -
16 7 - 4.08 1.82 - 5.10 2.50 -
18 7 - 4.50 1.80 - 5.45 2.45 -
10 10 - 2.70 2.70 - 3.60 3.60 -
13 10 - 3.41 2.49 - 4.22 3.38 -
16 10 - 3.94 2.36 - 4.57 3.33 -
18 10 - 4.09 2.21 - 4.74 3.16 -
13 13 - 3.15 3.15 - 3.95 3.95 -
16 13 - 3.73 3.07 - 4.35 3.95 -
18 13 - 3.91 2.89 - 4.53 3.77 -
16 16 - 3.60 3.60 - 4.30 4.30 -
18 16 - 3.79 3.41 - 4.49 4.11 -
18 18 - 3.60 3.60 - 4.30 4.30 -
3 units
7 7 7 2.00 2.00 2.00 2.70 2.70 2.70
10 7 7 2.70 2.00 2.00 3.53 2.38 2.38
13 7 7 3.56 1.92 1.92 4.28 2.31 2.31
16 7 7 3.92 1.74 1.74 4.49 2.20 2.20
18 7 7 4.11 1.64 1.64 4.68 2.11 2.11
10 10 7 2.70 2.70 2.00 3.18 3.18 2.14
13 10 7 3.26 2.38 1.76 3.80 3.04 2.05
16 10 7 3.62 2.17 1.61 4.01 2.92 1.97
18 10 7 3.81 2.06 1.53 4.20 2.80 1.89
13 13 7 2.91 2.91 1.57 3.50 3.50 1.89
16 13 7 3.26 2.68 1.45 3.71 3.37 1.82
18 13 7 3.46 2.56 1.38 3.90 3.25 1.75
16 16 7 3.03 3.03 1.35 3.57 3.57 1.75
18 16 7 3.22 2.90 1.29 3.76 3.45 1.69
10 10 10 2.47 2.47 2.47 2.97 2.97 2.97
13 10 10 3.01 2.20 2.20 3.42 2.74 2.74
16 10 10 3.36 2.02 2.02 3.63 2.64 2.64
18 10 10 3.56 1.92 1.92 3.81 2.54 2.54
13 13 10 2.71 2.71 1.98 3.18 3.18 2.54
16 13 10 3.06 2.51 1.83 3.38 3.07 2.46
18 13 10 3.25 2.40 1.75 3.56 2.97 2.37
16 16 10 2.85 2.85 1.71 3.26 3.26 2.37
18 16 10 3.03 2.73 1.64 3.45 3.16 2.30
13 13 13 2.47 2.47 2.47 2.97 2.97 2.97
16 13 13 2.80 2.30 2.30 3.16 2.87 2.87
18 13 13 2.98 2.21 2.21 3.34 2.78 2.78
16 16 13 2.66 2.66 2.19 3.09 3.09 2.81
18 16 13 2.84 2.56 2.10 3.27 3.00 2.73
16 16 16 2.50 2.50 2.50 3.00 3.00 3.00
18 16 16 2.68 2.41 2.41 3.18 2.91 2.91
@amp_aircon | amp-air-conditioning 26
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Combination Tables
RAS-
4M27
S3A
V-E
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)Supply Status A B C D A B C D A B C D
230V
2 units
7 7 - - 2.00 2.00 - - 2.70 2.70 - -
10 7 - - 2.70 2.00 - - 4.00 2.70 - -
13 7 - - 3.70 2.00 - - 4.81 2.59 - -
16 7 - - 4.08 1.82 - - 5.10 2.50 - -
18 7 - - 4.50 1.80 - - 5.45 2.45 - -
10 10 - - 2.70 2.70 - - 3.60 3.60 - -
13 10 - - 3.41 2.49 - - 4.22 3.38 - -
16 10 - - 3.94 2.36 - - 4.57 3.33 - -
18 10 - - 4.09 2.21 - - 4.74 3.16 - -
13 13 - - 3.15 3.15 - - 3.95 3.95 - -
16 13 - - 3.73 3.07 - - 4.35 3.95 - -
18 13 - - 3.91 2.89 - - 4.53 3.77 - -
16 16 - - 3.60 3.60 - - 4.30 4.30 - -
18 16 - - 3.79 3.41 - - 4.49 4.11 - -
18 18 - - 3.60 3.60 - - 4.30 4.30 - -
3 units
7 7 7 - 2.00 2.00 2.00 - 2.70 2.70 2.70 -
10 7 7 - 2.70 2.00 2.00 - 3.53 2.38 2.38 -
13 7 7 - 3.65 1.97 1.97 - 4.13 2.23 2.23 -
16 7 7 - 4.80 1.81 1.81 - 4.39 2.16 2.16 -
18 7 7 - 4.28 1.71 1.71 - 4.58 2.06 2.06 -
10 10 7 - 2.70 2.70 2.00 - 3.18 3.18 2.14 -
13 10 7 - 3.39 2.48 1.83 - 3.72 2.97 2.01 -
16 10 7 - 3.77 2.26 1.67 - 3.92 2.85 1.93 -
18 10 7 - 3.97 2.14 1.59 - 4.11 2.74 1.85 -
13 13 7 - 3.03 3.03 1.64 - 3.43 3.43 1.85 -
16 13 7 - 3.44 2.83 1.53 - 3.67 3.33 1.80 -
18 13 7 - 3.64 2.70 1.46 - 3.85 3.21 1.73 -
16 16 7 - 3.19 3.19 1.42 - 3.57 3.57 1.75 -
18 16 7 - 3.39 3.05 1.36 - 3.76 3.45 1.69 -
18 18 7 - 3.29 3.29 1.32 - 3.63 3.63 1.63 -
10 10 10 - 2.53 2.53 2.53 - 2.87 2.87 2.87 -
13 10 10 - 3.13 2.28 2.28 - 3.35 2.68 2.68 -
16 10 10 - 3.50 2.10 2.10 - 3.54 2.58 2.58 -
18 10 10 - 3.70 2.00 2.00 - 3.73 2.49 2.49 -
13 13 10 - 2.82 2.82 2.06 - 3.11 3.11 2.49 -
16 13 10 - 3.22 2.65 1.93 - 3.34 3.03 2.43 -
18 13 10 - 3.42 2.53 1.85 - 3.56 2.97 2.37 -
16 16 10 - 3.04 3.04 1.82 - 3.26 3.26 2.37 -
18 16 10 - 3.20 2.88 1.73 - 3.45 3.16 2.30 -
18 18 10 - 3.11 3.11 1.68 - 3.34 3.34 2.23 -
13 13 13 - 2.60 2.60 2.60 - 2.93 2.93 2.93 -
16 13 13 - 2.99 2.46 2.46 - 3.16 2.87 2.87 -
18 13 13 - 3.19 2.36 2.36 - 3.34 2.78 2.78 -
16 16 13 - 2.80 2.80 2.30 - 3.06 3.06 2.78 -
18 16 13 - 2.99 2.69 2.21 - 3.24 2.97 2.70 -
18 18 13 - 2.88 2.88 2.13 - 3.14 3.14 2.62 -
16 16 16 - 2.63 2.63 2.63 - 2.97 2.97 2.97 -
ampair.co.uk | 01707 378 670 | [email protected] 27
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Combination Tables
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)Supply Status A B C D A B C D A B C D
RAS-
4M27
S3A
V-E
230V 4 units
7 7 7 7 1.78 1.78 1.78 1.78 2.09 2.09 2.09 2.09
10 7 7 7 2.33 1.72 1.72 1.72 2.80 1.89 1.89 1.89
13 7 7 7 2.90 1.57 1.57 1.57 3.30 1.78 1.78 1.78
16 7 7 7 3.30 1.47 1.47 1.47 3.53 1.73 1.73 1.73
18 7 7 7 3.55 1.42 1.42 1.42 3.75 1.69 1.69 1.69
10 10 7 7 2.18 2.18 1.62 1.62 2.58 2.58 1.74 1.74
13 10 7 7 2.74 2.00 1.48 1.48 3.03 2.43 1.64 1.64
16 10 7 7 3.13 1.88 1.39 1.39 3.26 2.37 1.60 1.60
18 10 7 7 3.38 1.82 1.35 1.35 3.47 2.31 1.56 1.56
13 13 7 7 2.56 2.56 1.39 1.39 2.89 2.89 1.56 1.56
16 13 7 7 2.91 2.40 1.30 1.30 3.08 2.80 1.51 1.51
18 13 7 7 3.11 2.30 1.24 1.24 3.26 2.71 1.47 1.47
16 16 7 7 2.73 2.73 1.22 1.22 2.98 2.98 1.47 1.47
18 16 7 7 2.93 2.63 1.17 1.17 3.16 2.90 1.42 1.42
18 18 7 7 2.82 2.82 1.13 1.13 3.07 3.07 1.38 1.38
10 10 10 7 2.03 2.03 2.03 1.50 2.35 2.35 2.35 1.59
13 10 10 7 2.60 1.90 1.90 1.41 2.81 2.25 2.25 1.52
16 10 10 7 2.99 1.79 1.79 1.33 3.02 2.20 2.20 1.48
18 10 10 7 3.19 1.72 1.72 1.27 3.20 2.13 2.13 1.44
13 13 10 7 2.42 2.42 1.76 1.31 2.66 2.66 2.13 1.44
16 13 10 7 2.76 2.27 1.65 1.22 2.85 2.59 2.07 1.40
18 13 10 7 2.95 2.18 1.59 1.18 3.02 2.51 2.01 1.36
16 16 10 7 2.59 2.59 1.56 1.15 2.77 2.77 2.01 1.36
18 16 10 7 2.78 2.50 1.50 1.11 2.93 2.69 1.96 1.32
18 18 10 7 2.72 2.72 1.47 1.09 2.89 2.89 1.93 1.30
13 13 13 7 2.23 2.23 2.23 1.21 2.51 2.51 2.51 1.36
16 13 13 7 2.56 2.10 2.10 1.14 2.69 2.45 2.45 1.32
18 13 13 7 2.74 2.03 2.03 1.10 2.86 2.38 2.38 1.29
16 16 13 7 2.45 2.45 2.01 1.09 2.65 2.65 2.41 1.30
18 16 13 7 2.63 2.37 1.95 1.05 2.81 2.58 2.34 1.27
10 10 10 10 1.98 1.98 1.98 1.98 2.18 2.18 2.18 2.18
13 10 10 10 2.48 1.81 1.81 1.81 2.62 2.09 2.09 2.09
16 10 10 10 2.82 1.69 1.69 1.69 2.80 2.03 2.03 2.03
18 10 10 10 3.02 1.63 1.63 1.63 2.97 1.98 1.98 1.98
13 13 10 10 2.28 2.28 1.67 1.67 2.47 2.47 1.98 1.98
16 13 10 10 2.61 2.15 1.57 1.57 2.65 2.41 1.92 1.92
16 16 10 10 2.50 2.50 1.50 1.50 2.61 2.61 1.89 1.89
18 13 10 10 2.80 2.07 1.51 1.51 2.81 2.34 1.87 1.87
18 16 10 10 2.68 2.42 1.45 1.45 2.77 2.54 1.85 1.85
13 13 13 10 2.12 2.12 2.12 1.55 2.34 2.34 2.34 1.87
16 13 13 10 2.47 2.03 2.03 1.48 2.54 2.31 2.31 1.85
18 13 13 10 2.65 1.96 1.96 1.43 2.70 2.25 2.25 1.80
13 13 13 13 2.00 2.00 2.00 2.00 2.25 2.25 2.25 2.25
RAS
Resi
dent
ial
@amp_aircon | amp-air-conditioning 28
RAS ResidentialMulti Split - Combination Tables
RAS-
5M34
53A
V-E
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)Supply Status A B C D E A B C D E A B C D E
230V
1 unit
7 - - - - 2.00 - - - - 2.70 - - - -
10 - - - - 2.70 - - - - 4.00 - - - -
13 - - - - 3.70 - - - - 5.00 - - - -
16 - - - - 4.50 - - - - 5.50 - - - -
18 - - - - 5.00 - - - - 6.00 - - - -
2 units
7 7 - - - 2.00 2.00 - - - 2.70 2.70 - - -
10 7 - - - 2.70 2.00 - - - 4.00 2.70 - - -
13 7 - - - 3.70 2.00 - - - 4.81 2.59 - - -
16 7 - - - 4.08 1.82 - - - 5.10 2.50 - - -
18 7 - - - 4.50 1.80 - - - 5.45 2.45 - - -
10 10 - - - 2.70 2.70 - - - 3.60 3.60 - - -
13 10 - - - 3.41 2.49 - - - 4.22 3.38 - - -
16 10 - - - 3.94 2.36 - - - 4.57 3.33 - - -
18 10 - - - 4.09 2.21 - - - 4.74 3.16 - - -
13 13 - - - 3.15 3.15 - - - 3.95 3.95 - - -
16 13 - - - 3.73 3.07 - - - 4.35 3.95 - - -
18 13 - - - 3.91 2.89 - - - 4.53 3.77 - - -
16 16 - - - 3.60 3.60 - - - 4.30 4.30 - - -
18 16 - - - 3.79 3.41 - - - 4.49 4.11 - - -
18 18 - - - 3.60 3.60 - - - 4.30 4.30 - - -
3 units
7 7 7 - - 2.00 2.00 2.00 - - 2.70 2.70 2.70 - -
10 7 7 - - 2.70 2.00 2.00 - - 3.53 2.38 2.38 - -
13 7 7 - - 3.65 1.97 1.97 - - 4.13 2.23 2.23 - -
16 7 7 - - 4.08 1.81 1.81 - - 4.39 2.16 2.16 - -
18 7 7 - - 4.28 1.71 1.71 - - 4.58 2.06 2.06 - -
10 10 7 - - 2.70 2.70 2.00 - - 3.18 3.18 2.14 - -
13 10 7 - - 3.39 2.48 1.83 - - 3.72 2.97 2.01 - -
16 10 7 - - 3.77 2.26 1.67 - - 3.92 2.85 1.93 - -
18 10 7 - - 3.97 2.14 1.59 - - 4.11 2.74 1.85 - -
13 13 7 - - 3.03 3.03 1.64 - - 3.43 3.43 1.85 - -
16 13 7 - - 3.44 2.83 1.53 - - 3.67 3.33 1.80 - -
18 13 7 - - 3.64 2.70 1.46 - - 3.85 3.21 1.73 - -
16 16 7 - - 3.19 3.19 1.42 - - 3.57 3.57 1.75 - -
18 16 7 - - 3.39 3.05 1.36 - - 3.76 3.45 1.69 - -
18 18 7 - - 3.29 3.29 1.32 - - 3.63 3.63 1.63 - -
10 10 10 - - 2.53 2.53 2.53 - - 2.87 2.87 2.87 - -
13 10 10 - - 3.13 2.28 2.28 - - 3.35 2.68 2.68 - -
16 10 10 - - 3.50 2.10 2.10 - - 3.54 2.58 2.58 - -
18 10 10 - - 3.70 2.00 2.00 - - 3.73 2.49 2.49 - -
13 13 10 - - 2.82 2.82 2.06 - - 3.11 3.11 2.49 - -
16 13 10 - - 3.22 2.65 1.93 - - 3.34 3.03 2.43 - -
18 13 10 - - 3.42 2.53 1.85 - - 3.56 2.97 2.37 - -
16 16 10 - - 3.04 3.04 1.82 - - 3.26 3.26 2.37 - -
18 16 10 - - 3.20 2.88 1.73 - - 3.45 3.16 2.30 - -
18 18 10 - - 3.11 3.11 1.68 - - 3.34 3.34 2.23 - -
13 13 13 - - 2.60 2.60 2.60 - - 2.93 2.93 2.93 - -
16 13 13 - - 2.99 2.46 2.46 - - 3.16 2.87 2.87 - -
18 13 13 - - 3.19 2.36 2.36 - - 3.34 2.78 2.78 - -
16 16 13 - - 2.80 2.80 2.30 - - 3.06 3.06 2.78 - -
16 16 16 - - 2.67 2.67 2.67 - - 2.97 2.97 2.97 - -
18 16 13 - - 2.99 2.69 2.21 - - 3.24 2.97 2.70 - -
18 18 13 - - 2.88 2.88 2.13 - - 3.14 3.14 2.62 - -
RAS
Resi
dent
ial
ampair.co.uk | 01707 378 670 | [email protected] 29
RAS ResidentialMulti Split - Combination Tables
RAS-
5M34
53A
V-E
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)Supply Status A B C D E A B C D E A B C D E
230V 4 units
7 7 7 7 - 2.00 2.00 2.00 2.00 - 2.33 2.33 2.33 2.33 -
10 7 7 7 - 2.61 1.93 1.93 1.93 - 3.11 2.10 2.10 2.10 -
13 7 7 7 - 3.28 1.77 1.77 1.77 - 3.66 1.98 1.98 1.98 -
16 7 7 7 - 3.73 1.66 1.66 1.66 - 3.92 1.93 1.93 1.93 -
18 7 7 7 - 4.00 1.60 1.60 1.60 - 4.17 1.88 1.88 1.88 -
10 10 7 7 - 2.44 2.44 1.81 1.81 - 2.84 2.84 1.91 1.91 -
13 10 7 7 - 3.10 2.26 1.67 1.67 - 3.37 2.69 1.82 1.82 -
16 10 7 7 - 3.54 2.12 1.57 1.57 - 3.62 2.63 1.78 1.78 -
18 10 7 7 - 3.80 2.05 1.52 1.52 - 3.86 2.57 1.74 1.74 -
13 13 7 7 - 2.89 2.89 1.56 1.56 - 3.21 3.21 1.74 1.74 -
16 13 7 7 - 3.32 2.73 1.48 1.48 - 3.46 3.14 1.70 1.70 -
18 13 7 7 - 3.54 2.62 1.42 1.42 - 3.66 3.05 1.65 1.65 -
16 16 7 7 - 3.12 3.12 1.38 1.38 - 3.35 3.35 1.65 1.65 -
18 16 7 7 - 3.33 3.00 1.33 1.33 - 3.35 3.25 1.60 1.60 -
18 18 7 7 - 3.21 3.21 1.29 1.29 - 3.45 3.45 1.55 1.55 -
10 10 10 7 - 2.30 2.30 2.30 1.70 - 2.61 2.61 2.61 1.76 -
13 10 10 7 - 2.93 2.14 2.14 1.59 - 3.12 2.50 2.50 1.69 -
16 10 10 7 - 3.37 2.02 2.02 1.50 - 3.36 2.44 2.44 1.65 -
18 10 10 7 - 3.63 1.96 1.96 1.45 - 3.59 2.40 2.40 1.62 -
13 13 10 7 - 2.75 2.75 2.01 1.49 - 2.99 2.99 2.40 1.62 -
16 13 10 7 - 3.14 2.58 1.88 1.40 - 3.20 2.91 2.33 1.57 -
18 13 10 7 - 3.36 2.49 1.81 1.34 - 3.39 2.82 2.26 1.53 -
16 16 10 7 - 2.96 2.96 1.77 1.31 - 3.11 3.11 2.26 1.53 -
18 16 10 7 - 3.17 2.85 1.71 1.27 - 3.30 3.02 2.20 1.48 -
18 18 10 7 - 3.06 3.06 1.65 1.22 - 3.21 3.21 2.14 1.44 -13 13 13 7 - 2.54 2.54 2.54 1.37 - 2.82 2.82 2.82 1.53 -
16 13 13 7 - 2.91 2.40 2.40 1.29 - 3.02 2.75 2.75 1.48 -
18 13 13 7 - 3.13 2.31 2.31 1.25 - 3.21 2.67 2.67 1.44 -
16 16 13 7 - 2.76 2.76 2.27 1.22 - 2.94 2.94 2.67 1.44 -
18 16 13 7 - 2.96 2.66 2.19 1.18 - 3.13 2.86 2.60 1.41 -
18 18 13 7 - 2.87 2.87 2.12 1.15 - 3.05 3.05 2.54 1.37 -
10 10 10 10 - 2.18 2.18 2.18 2.18 - 2.43 2.43 2.43 2.43 -
13 10 10 10 - 2.79 2.04 2.04 2.04 - 2.91 2.33 2.33 2.33 -
16 10 10 10 - 3.21 1.93 1.93 1.93 - 3.14 2.29 2.29 2.29 -
18 10 10 10 - 3.44 1.85 1.85 1.85 - 3.33 2.22 2.22 2.22 -
13 13 10 10 - 2.60 2.60 1.90 1.90 - 2.78 2.78 2.22 2.22 -
16 13 10 10 - 2.98 2.45 1.79 1.79 - 2.97 2.70 2.16 2.16 -
16 16 10 10 - 2.81 2.81 1.69 1.69 - 2.89 2.89 2.11 2.11 -
18 13 10 10 - 3.19 2.36 1.72 1.72 - 3.16 2.63 2.11 2.11 -
18 16 10 10 - 3.02 2.72 1.63 1.63 - 2.08 2.82 2.05 2.05 -
18 18 10 10 - 2.92 2.92 1.58 1.58 - 3.00 3.00 2.00 2.00 -
13 13 13 10 - 2.41 2.41 2.41 1.76 - 2.63 2.63 2.63 2.11 -
16 13 13 10 - 2.77 2.28 2.28 1.66 - 2.82 2.56 2.56 2.05 -
16 16 13 10 - 2.63 2.63 2.16 1.58 - 2.75 2.75 2.50 2.00 -
18 13 13 10 - 2.98 2.21 2.21 1.61 - 3.00 2.50 2.50 2.00 -
18 16 13 10 - 2.83 2.55 2.09 1.53 - 2.93 2.68 2.44 1.95 -
18 18 13 10 - 2.74 2.74 2.03 1.48 - 2.86 2.86 2.38 1.90 -
13 13 13 13 - 2.25 2.25 2.25 2.25 - 2.50 2.50 2.50 2.50 -
16 13 13 13 - 2.60 2.13 2.13 2.13 - 2.68 2.44 2.44 2.44 -
18 13 13 13 - 2.80 2.07 2.07 2.07 - 2.86 2.38 2.38 2.38 -
16 16 13 13 - 2.47 2.47 2.03 2.03 - 2.62 2.62 2.38 2.38 -
18 16 13 13 - 2.66 2.40 1.97 1.97 - 2.79 2.56 2.33 2.33 -
18 18 13 13 - 2.59 2.59 1.91 1.91 - 2.73 2.73 2.27 2.27 -
ampair.co.uk | 01707 378 670 | [email protected] 29
@amp_aircon | amp-air-conditioning 30
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Combination Tables
RAS-
5M34
53A
V-E
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)Supply Status A B C D E A B C D E A B C D E
230V 5 units
7 7 7 7 7 1.96 1.96 1.96 1.96 1.96 2.28 2.28 2.28 2.28 2.28
10 7 7 7 7 2.50 1.85 1.85 1.85 1.85 3.16 2.13 2.13 2.13 2.13
13 7 7 7 7 3.13 1.69 1.69 1.69 1.69 3.70 2.00 2.00 2.00 2.00
16 7 7 7 7 3.56 1.58 1.58 1.58 1.58 3.95 1.94 1.94 1.94 1.94
18 7 7 7 7 3.81 1.52 1.52 1.52 1.52 4.18 1.88 1.88 1.88 1.88
10 10 7 7 7 2.34 2.34 1.74 1.74 1.74 2.91 2.91 1.96 1.96 1.96
13 10 7 7 7 2.95 2.16 1.60 1.60 1.60 3.42 2.74 1.85 1.85 1.85
16 10 7 7 7 3.38 2.03 1.50 1.50 1.50 3.66 2.66 1.79 1.79 1.79
18 10 7 7 7 3.61 1.95 1.45 1.45 1.45 3.88 2.59 1.75 1.75 1.75
13 13 7 7 7 2.73 2.73 1.48 1.48 1.48 3.23 3.23 1.75 1.75 1.75
16 13 7 7 7 3.14 2.58 1.39 1.39 1.39 3.46 3.15 1.70 1.70 1.70
18 13 7 7 7 3.37 2.49 1.35 1.35 1.35 3.68 3.06 1.65 1.65 1.65
16 16 7 7 7 2.97 2.97 1.32 1.32 1.32 3.37 3.37 1.65 1.65 1.65
18 16 7 7 7 3.19 2.87 1.28 1.28 1.28 3.58 3.28 1.61 1.61 1.61
10 10 10 7 7 2.21 2.21 2.21 1.64 1.64 2.69 2.69 2.69 1.82 1.82
13 10 10 7 7 2.80 2.04 2.04 1.51 1.51 3.18 2.54 2.54 1.72 1.72
13 13 10 7 7 2.60 2.60 1.90 1.40 1.40 3.02 3.02 2.41 1.63 1.63
16 10 10 7 7 3.21 1.92 1.92 1.42 1.42 3.40 2.48 2.48 1.67 1.67
18 10 10 7 7 3.44 1.86 1.86 1.38 1.38 3.62 2.41 2.41 1.63 1.63
13 13 13 7 7 2.43 2.43 2.43 1.31 1.31 2.87 2.87 2.87 1.55 1.55
16 13 13 7 7 2.80 2.30 2.30 1.25 1.25 3.08 2.80 2.80 1.51 1.51
18 13 13 7 7 3.02 2.23 2.23 1.21 1.21 3.28 2.73 2.73 1.48 1.48
16 16 10 7 7 2.84 2.84 1.70 1.26 1.26 3.15 3.15 2.29 1.55 1.55
18 16 10 7 7 3.06 2.75 1.65 1.22 1.22 3.36 3.08 2.24 1.51 1.51
16 16 13 7 7 2.67 2.67 2.19 1.19 1.19 3.01 3.01 2.73 1.48 1.4818 16 13 7 7 2.88 2.59 2.13 1.15 1.15 3.21 2.94 2.67 1.44 1.44
10 10 10 10 7 2.09 2.09 2.09 2.09 1.55 2.50 2.50 2.50 1.50 1.69
13 10 10 10 7 2.65 1.94 1.94 1.94 1.43 2.97 2.38 2.38 1.38 1.60
16 10 10 10 7 3.05 1.83 1.83 1.83 1.36 3.19 2.32 2.32 2.32 1.56
18 10 10 10 7 3.28 1.77 1.77 1.77 1.31 3.39 2.26 2.26 2.26 1.53
13 13 10 10 7 2.48 2.48 1.81 1.81 1.34 2.83 2.83 2.26 2.26 1.53
16 13 10 10 7 2.86 2.35 1.71 1.71 1.27 3.04 2.76 2.21 2.21 1.49
18 13 10 10 7 3.07 2.28 1.66 1.66 1.23 3.24 2.70 2.16 2.16 1.46
16 16 10 10 7 2.72 2.72 1.63 1.63 1.21 2.97 2.97 2.16 2.16 1.46
13 13 13 10 7 2.32 2.32 2.32 1.69 1.25 2.70 2.70 2.70 2.16 1.46
16 13 13 10 7 2.68 2.21 2.21 1.61 1.19 2.90 2.64 2.64 2.11 1.42
16 16 13 10 7 2.56 2.56 2.11 1.54 1.14 2.83 2.83 2.58 2.06 1.39
13 13 13 13 7 2.18 2.18 2.18 2.18 1.18 2.58 2.58 2.58 2.58 1.39
16 13 13 13 7 2.53 2.08 2.08 2.08 1.13 2.77 2.52 2.52 2.52 1.36
16 16 13 13 7 2.42 2.42 1.99 1.99 1.08 2.72 2.72 2.47 2.47 1.33
10 10 10 10 10 1.98 1.98 1.98 1.98 1.98 2.34 2.34 2.34 2.34 2.34
13 10 10 10 10 2.53 1.84 1.84 1.84 1.84 2.79 2.23 2.23 2.23 2.23
16 10 10 10 10 2.91 1.75 1.75 1.75 1.75 2.99 2.18 2.18 2.18 2.18
18 10 10 10 10 3.13 1.69 1.69 1.69 1.69 3.19 2.13 2.13 2.13 2.13
13 13 10 10 10 2.36 2.36 1.72 1.72 1.72 2.66 2.66 2.13 2.13 2.13
16 13 10 10 10 2.73 2.25 1.64 1.64 1.64 2.86 2.60 2.08 2.08 2.08
18 13 10 10 10 2.95 2.18 1.59 1.59 1.59 3.05 2.54 2.03 2.03 2.03
16 16 10 10 10 2.61 2.61 1.56 1.56 1.56 2.80 2.80 2.03 2.03 2.03
13 13 13 10 10 2.22 2.22 2.22 1.62 1.62 2.54 2.54 2.54 2.03 2.03
16 13 13 10 10 2.58 2.12 2.12 1.55 1.55 2.74 2.49 2.49 1.99 1.99
18 13 13 10 10 2.78 2.06 2.06 1.50 1.50 2.93 2.44 2.44 1.95 1.95
@amp_aircon | amp-air-conditioning 30
ampair.co.uk | 01707 378 670 | [email protected] 31
RAS
Resi
dent
ial
RAS ResidentialMulti Split - Combination Tables
RAS-
5M34
53A
V-E
Power Operating Indoor Unit Cooling Capacity (kW) Heating Capacity (kW)Supply Status A B C D E A B C D E A B C D E
230V 5 units
16 16 13 10 10 2.49 2.49 2.04 1.49 1.49 2.85 2.75 2.50 2.00 2.00
13 13 13 13 10 2.09 2.09 2.09 2.09 1.53 2.44 2.44 2.44 2.44 1.95
16 13 13 13 10 2.46 2.02 2.02 2.02 1.48 2.69 2.45 2.45 2.45 1.96
18 13 13 13 10 2.66 1.97 1.97 1.97 1.44 2.88 2.40 2.40 2.40 1.92
16 16 13 13 10 2.36 2.36 1.94 1.94 1.41 2.64 2.64 2.40 2.40 1.92
13 13 13 13 10 2.00 2.00 2.00 2.00 2.00 2.40 2.40 2.40 2.40 2.40
16 13 13 13 10 2.33 1.92 1.92 1.92 1.92 2.59 2.35 2.35 2.35 2.35
Toshiba Rewards, the new loyalty scheme from Toshiba, see page 207 for details
ampair.co.uk | 01707 378 670 | [email protected] 31
RAS
Resi
dent
ial
@amp_aircon | amp-air-conditioning 32
Photo: Sarah Smith, Internal Sales Administrator at AMP
TAKING OMFORT TO A
WHOLE NEW DIMENSIONc
See the new SMMSe VRF Heat Pump Range on page 85
ampair.co.uk | 01707 378 670 | [email protected] 33ampair.co.uk | 01707 378 670 | [email protected] 33
RAV Split Systems
RAV
Com
mer
cial
Toshiba installation at Mercedes Beaconsfield, courtesy of Tencer Ltd
TAKING OMFORT TO A
WHOLE NEW DIMENSION
@amp_aircon | amp-air-conditioning 34
RAV
Com
mer
cial
RAV Split SystemsIntroduction
Toshiba Digital and Super Digital Inverter systems deliver exceptional operating savings in extremely compact units. With state-of-the-art technologies, flexible controls and flexible installation they bring comfort and convenience.
The technology of the Digital Inverter control module ensures optimised reproduction of the supply sine wave at the desired frequency, in order to reduce inefficient harmonics that inverters normally emit. With this innovative control method, the Toshiba Digital Inverter brings state-of-the-art inverter technology to the commercial sector, offering considerable advantages in terms of capacity, energy savings and optimised control.
The Super Digital Inverter provides industry leading part load efficiency in cooling and heating mode. In most applications, these systems can reduce the Seasonal Energy Consumption. The variable capacity management of the compressor allows the Digital and Super Digital Inverter to maintain room temperature control and to ensure minimum energy wastage.
Super Digital and Digital Inverter systems are capable of satisfying applications that require cooling at low operating conditions down to –15°C, while powerful heating capacities are possible at –20°C outdoor temperature.
Thanks to the filter positioned in the refrigerant circuit, the SDI and DI systems, equipped with R410A refrigerant, can use pipework designed for old R22 or R407C refrigerant. High-mesh filters and stable lubricant oil against chloride compounds, combined with high-tech Toshiba control, are key to make SDI and DI units suitable for reuse of existing piping. This solution offers significant benefits in terms of performance, acoustic comfort and efficiency.
ampair.co.uk | 01707 378 670 | [email protected] 35
RAV
Com
mer
cial
RAV Split SystemsRange Overview
Nominal Cooling
2.5 3.6 5.0 6.7 10.0 12.0 14.0 20.0 25.0
KRT-E Wall Mounted
Digital Inverter 1Ph(37)
1Ph(37)
1Ph(38)
1Ph(38)
Super Digital Inverter
1Ph(39)
1Ph(39)
1Ph(39)
MUT-E Compact Cassette
Digital Inverter 1Ph(41)
1Ph(41)
1Ph(41)
Super Digital Inverter
1Ph(42)
1Ph(42)
UTP-E 4 Way Cassette
Digital Inverter 1Ph(44)
1Ph(44)
1Ph(44)
1Ph(45)
1Ph(45)
Super Digital Inverter
1Ph(46)
1Ph(46)
1Ph(47)3Ph(48)
1Ph(47)3Ph(48)
3Ph(48)
SDT-E Low Static Ducted
Digital Inverter 1Ph(50)
1Ph(50)
1Ph(50)
Super Digital Inverter
1Ph(51)
1Ph(51)
BTP-E Standard Ducted
Digital Inverter 1Ph(53)
1Ph(53)
1Ph(53)
1Ph(54)
1Ph(54)
1Ph(54)
Super Digital Inverter
1Ph(55)
1Ph(55)
1Ph(55)
1Ph(56)3Ph(57)
1Ph(56)3Ph(57)
3Ph(57)
DT-E High Static Ducted
Digital Inverter 3Ph(59)
3Ph(59)
Super Digital Inverter
CTP-E Ceiling Suspended
Digital Inverter 1Ph(61)
1Ph(61)
1Ph(61)
1Ph(62)
1Ph(62)
1Ph(62)
Super Digital Inverter
1Ph(63)
1Ph(63)
1Ph(63)
1Ph(64)3Ph(65)
1Ph(64)3Ph(65)
3Ph(65)
Page numbers are shown in brackets | Floor standing converted systems are also available. See page 66 - 68 for details | Twin, Triple and quad systems also available. See pages 70 - 79 for details.
@amp_aircon | amp-air-conditioning 36
RAV
Com
mer
cial
RAV Split SystemsKRT-E Wall Mounted
» High efficiency twin rotary inverter compressor» Replacement technology (R22 & R407c)
» High performance operation using digital inverter control system
» Enhanced filtration system» TCC link remote control options (optional)
» Auto louver mode allows optimum air distribution» Infrared and wired controls available
Super Digital Inverter outdoor unitKRT-E Wall Mounted Indoor Unit
Compatible Accessories
Part No. Description ListPrice
RBC-AMT32E Wired Remote Controller £50
RBC-AM-S41E
Wired remote controller with 7-day time clock £66
RBC-AM-S54E-ES
Premium wired remote controller with 7-day time clock £105
RBC-AS41E Simplified wired remote controller £70
AMP-TRF Adapter for run/fault (12V DC output) £16
AMP-TRFVF Adapter for run/fault (volt free) £68
AMP-TRFVF+ Adapter for run/fault (volt free) with 24V DC on/off £110
With its slim-line design, the Super Digital Inverter high-wall unit is ideal for offices, restaurants and other applications where elegance is required.
ExistingPipe Sizes Allowable Outdoors
Liquid Gas Digital Inverter Super Digital Inverter
1/4" 3/8" 304, 404 404
1/4" 1/2" 304, 404, 564, 804 404, 564, 804
1/4" 5/8" 404, 564, 804 404, 564, 804
3/8" 3/8" 304
3/8" 1/2" 304, 404, 564, 804 404, 564, 804
3/8" 5/8" 404, 564, 804 404, 564, 804
3/8" 3/4" 804 804
Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information
Contact AMP for details.
ampair.co.uk | 01707 378 670 | [email protected] 37
RAV
Com
mer
cial
RAV Split SystemsWall Mounted Digital Inverter
Indoor Unit RAV-SM307KRTP-E RAV-SM407KRTP-E
Infrared Remote Controller Included Included
Outdoor Unit RAV-SM304ATP-E RAV-SM404ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 2.5 (0.9 - 3.0) 3.6 (0.9 - 4.0)
UK Cooling (Total - Sensible) kW 2.40 - 1.90 3.45 - 2.70
Nominal Heating (Range) kW 3.4 (0.8 - 4.5) 4.0 (0.8 - 5.0)
UK Heating kW 2.2 2.6
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.90 - 4.00 5.40 - 4.12
Energy Efficiency Class (Cool / Heat) A+ / A+ A / A+
EER - COP (Cool - Heat) 4.10 - 4.00 3.19 - 3.57
Energy Label (Cool / Heat) TBC TBC
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 275 - 790 - 217 275 - 790 - 217
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 10 - 33 10 - 39
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 83 - 128 - 158 83 - 145 - 191
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 29 - 37 - 41 30 - 40 - 45
Outdoor Sound Pressure (cool-heat) dB(A) 46 - 47 49 - 50
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 20 - 10 20 - 10
Pre-charged for m 15 15
Charge R410A (Factory - Additional) kg 0.8kg - 20g/m 1.4kg - 20g/m
Suitable for Replacement Tech. Yes Yes
Indoor Drain Connection mm VP16 (14id 16od) VP16 (14id 16od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Max Running Current A 3.86 5.14
Power Consumption (Cool - Heat) kW 0.61 - 0.85 1.13 - 1.12
Suggested Fuse Size A 10 10
Indoor Unit £292 £317
Outdoor Unit £588 £704
Retail Price £880 £1,021
Gravity drain | Rear, top, left or right piping.
Optional ControllerRBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 38
RAV
Com
mer
cial
RAV Split SystemsWall Mounted Digital Inverter
Indoor Unit RAV-SM566KRT-E RAV-SM806KRT-E
Infrared Remote Controller Included Included
Outdoor Unit RAV-SM564ATP-E RAV-SM804ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 5.0 (1.5 - 5.6) 6.7 (1.5 - 7.0)
UK Cooling (Total - Sensible) kW 4.8 - 3.4 6.4 - 4.5
Nominal Heating (Range) kW 5.3 (1.5 - 6.3) 7.7 (1.5 - 9.0)
UK Heating kW 3.8 5.5
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.77 - 4.00 5.62 - 4.01
Energy Efficiency Class (Cool / Heat) A+ / A+ A+ / A+
EER - COP (Cool - Heat) 3.01 - 3.42 2.75 - 2.95
Energy Label (Cool / Heat) B / B D / D
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 320 - 1050 - 228 320 - 1050 - 228
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 12 - 40 12 - 44
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 183 - 208 - 233 183 - 208 - 283
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 36 - 39 - 42 36 - 41 - 47
Outdoor Sound Pressure (cool-heat) dB(A) 46 - 48 48 - 52
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 30 - 30
Pre-charged for m 20 20
Charge R410A (Factory - Additional) kg 1.1kg - 20g/m 1.7kg - 40g/m
Suitable for Replacement Tech. Yes Yes
Indoor Drain Connection mm VP16 (14id 16od) VP16 (14id 16od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 7.78 - 7.26 11.43 - 12.23
Power Consumption (Cool - Heat) kW 1.66 - 1.55 2.44 - 2.61
Suggested Fuse Size - Max. Current A 16 - 12.3 20 - 15.5
Indoor Unit £391 £421
Outdoor Unit £840 £1,177
Retail Price £1,231 £1,598
Gravity drain | Rear, top, left or right piping.
ampair.co.uk | 01707 378 670 | [email protected] 39
RAV
Com
mer
cial
RAV Split SystemsWall Mounted Super Digital Inverter
Indoor Unit RAV-SM407KRTP-E RAV-SM566KRT-E RAV-SM806KRT-E
Infrared Remote Controller Included Included Included
Outdoor Unit RAV-SP404ATP-E RAV-SP564ATP-E RAV-SP804ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 3.6 (TBC) 5.0 (1.2 - 5.6) 7.1 (1.9 - 8.0)
UK Cooling (Total - Sensible) kW TBC 4.8 - 3.4 6.7 - 4.7
Nominal Heating (Range) kW 4.0 (TBC) 5.6 (0.9 - 7.3) 8.0 (1.3 - 10.6)
UK Heating kW TBC 3.7 5.2
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.40 - 4.12 5.82 - 4.01 5.88 - 3.87
Energy Efficiency Class (Cool / Heat) A / A+ A+ / A+ A+ / A
EER - COP (Cool - Heat) TBC 3.47 - 3.73 3.21 - 3.42
Energy Label (Cool / Heat) TBC A / A A / B
AMBI
ENT
RAN
GE Cooling °C 43°C to -15°C
Heating °C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 275 - 790 - 217 320 - 1050 - 228 320 - 1050 - 228
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 890 - 900 - 320
Weight (Indoor - Outdoor) kg 10 - 40 12 - 44 12 - 66
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 83 - 145 - 191 183 - 208 - 233 183 - 208 - 283
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 30 - 40 - 45 36 - 39 - 42 36 - 41 - 47
Outdoor Sound Pressure (cool-heat) dB(A) 45 - 47 47 - 48 48 - 49
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 1/2" - 1/4" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 50 - 30 50 - 30
Pre-charged for m 15 20 30
Charge R410A (Factory - Additional) kg 1.0kg - 20g/m 1.4kg - 20g/m 2.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP16 (14id 16od) VP16 (14id 16od) VP16 (14id 16od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 5.14 6.74 - 6.98 10.71 - 11.02
Power Consumption (Cool - Heat) kW 1.13 - 1.12 1.44 - 1.50 2.21 - 2.34
Suggested Fuse Size - Max. Current A 10 - TBC 16 - 13.4 25 - 20.4
Indoor Unit £317 £391 £421
Outdoor Unit £998 £1,097 £1,628
Retail Price £1,315 £1,488 £2,049
Gravity drain | Rear, top, left or right piping.
Optional ControllerRBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 40
RAV
Com
mer
cial
RAV Split SystemsMUT-E Compact Cassettes
» High efficiency twin rotary inverter compressor» Replacement technology (R22 & R407c)» Lightweight and easy to install» Built in drain pump up to 850mm» Self cleaning function and anti-mould drain pan» Removable corner pockets for easy access
» Infrared and wired controls available» Operational to -15°C in cooling and -20°C heating
Super digital outdoor unitMUT-E 4-way compact cassette
Compatible Accessories
Part No. Description ListPrice
RBC-AMT32E Wired Remote Controller £50
RBC-AM-S41E*
Wired remote controller with 7-day time clock £66
RBC-AM-S54E-ES
Premium wired remote controller with 7-day time clock £105
RBC-AS41E Simplified wired remote controller £70
TCB-AX32E2 Infrared remote controller kit £214
TCB-PCNT-30TLE2**
Network adapter for connection to central controllers £78
AMP-TRF Adapter for run/fault (12V DC output) £16
AMP-TRFVF Adapter for run/fault (volt free) £68
AMP-TRFVF+ Adapter for run/fault (volt free) with 24V DC on/off £110
*System princes include these as standard | **Require TCB-PX30MUE adapter box £59.00.
The Super Digital Inverter series of cassettes are unobtrusive and flexible easily blending in with any room interior. They offer high performance utilising minimum energy to help lower your power consumption.
ExistingPipe Sizes Allowable Outdoors
Liquid Gas Digital Inverter Super Digital Inverter
1/4" 3/8" 304, 404 404
1/4" 1/2" 304, 404, 564 404, 564
1/4" 5/8" 404, 564 404, 564
3/8" 3/8" 304
3/8" 1/2" 304, 404, 564 404, 564
3/8" 5/8" 404, 564 404, 564
Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information
Contact AMP for details.
ampair.co.uk | 01707 378 670 | [email protected] 41
RAV
Com
mer
cial
RAV Split SystemsCompact Cassettes Digital Inverter
Indoor Unit RAV-SM304MUT-E RAV-SM404MUT-E RAV-SM564MUT-E
Grille RBC-UM11PG(W)E RBC-UM11PG(W)E RBC-UM11PG(W)-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM304ATP-E RAV-SM404ATP-E RAV-SM564ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 2.5 (0.9 - 3.0) 3.6 (0.9 - 4.0) 5.0 (1.5 - 5.6)
UK Cooling (Total - Sensible) kW 2.40 - 1.95 3.45 - 2.79 4.80 - 3.50
Nominal Heating (Range) kW 3.4 (0.8 - 4.5) 4.0 (0.8 - 5.0) 5.3 (1.5 - 6.3)
UK Heating kW 2.18 2.56 3.79
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.53 - 4.27 5.35 - 4.27 5.48 - 4.16
Energy Efficiency Class (Cool / Heat) A / A+ A / A+ A / A+
EER - COP (Cool - Heat) 4.24 - 4.47 4.00 - 4.21 3.03 - 3.49
Energy Label (Cool / Heat) TBC TBC B / B
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 268 (27) - 575 (700) - 575 (700)
268 (27) - 575 (700) - 575 (700)
268(27)- 575(700 )- 575(700)
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 16 (3) - 33 16 (3) - 39 17 (3) - 40
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 122 - 144 - 177 130 - 153 - 183 152 - 187 - 222
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 31 - 36 - 40 31 - 36 - 40 34 - 39 - 43
Outdoor Sound Pressure (cool-heat) dB(A) 46 - 47 49 - 50 46 - 48
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 1/2" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 20 - 10 20 - 10 30 - 30
Pre-charged for m 15 15 20
Charge R410A (Factory - Additional) kg 0.8kg - 20g/m 1.4kg - 20g/m 1.1kg - 20g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 3.45 4.32 7.73 - 7.12
Power Consumption (Cool - Heat) kW 0.59 - 0.76 0.90 - 0.95 1.65 - 1.52
Suggested Fuse Size A 10 10 16 - 12.5
Indoor Unit £538 £532 £526
Grille / Spigot Kit £200 £200 £200
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £588 £704 £840
Retail Price £1,392 £1,502 £1,632
Lift pump, 850mm from the underside of the ceiling tile | Knock out for branch duct | Knock out for fresh air intake.
@amp_aircon | amp-air-conditioning 42
RAV
Com
mer
cial
RAV Split SystemsCompact Cassettes Super Digital Inverter
Indoor Unit RAV-SM404MUT-E RAV-SM564MUT-E
Grille RBC-UM11PG(W)-E RBC-UM11PG(W)-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP404ATP-E RAV-SP564ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 3.6 5.0
UK Cooling (Total - Sensible) kW 3.4 - 2.7 4.8 - 3.5
Nominal Heating (Range) kW 4.0 5.6
UK Heating kW 2.6 3.6
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.38 - 4.17 5.61 - 4.20
Energy Efficiency Class (Cool / Heat) A / A+ A+ / A+
EER - COP (Cool - Heat) 3.60 - 4.12 3.21 - 3.64
Energy Label (Cool / Heat) A / A A / A
AMBI
ENT
RAN
GE Cooling °C 43°C to -15°C 43°C to -15°C
Heating °C 15°C to -15°C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 268 (27) - 575 (700 ) - 575 (700) 268 (27) - 575 (700) - 575 (700)
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 17 (3) - 40 17 (3) - 44
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 130 - 153 - 183 152 - 187 - 222
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 31 - 36 - 40 34 - 39 - 43
Outdoor Sound Pressure (cool-heat) dB(A) 45 - 47 47 - 48
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 50 - 30
Pre-charged for m 20 20
Charge R410A (Factory - Additional) kg 1.0kg - 20g/m 1.4kg - 20g/m
Suitable for Replacement Tech. yes yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 5.05 - 4.79 7.24 - 7.14
Power Consumption (Cool - Heat) kW 1.00 - 0.97 1.56 - 1.54
Suggested Fuse Size - Max. Current A 20 - 15.0 16 - 13.6
Indoor Unit £532 £526
Grille / Spigot Kit £200 £200
Remote Controller inc. Time Clock £66 £66
Outdoor Unit £998 £1,097
Retail Price £1,796 £1,889
Lift pump, 850mm from the underside of the ceiling tile | Knock out for branch duct 105 x 105 | Knock out for fresh air intake 64 x 64.
ampair.co.uk | 01707 378 670 | [email protected] 43
RAV
Com
mer
cial
RAV Split SystemsUTP-E 4 Way Cassettes
» Replacement technology (R22 & R407c)» Lightweight and easy to install» Built in high lift drain pump up to 850mm» Self cleaning function and anti-mould drain pan» Removable corner pockets for easy access» Infrared and wired controls available» Detachable louver and grille for easy cleaning
Digital inverter twin fan outdoor unit.
Compatible Accessories
Part No. Description ListPrice
RBC-AMT32E Wired Remote Controller £50
RBC-AM-S41E*
Wired remote controller with 7-day time clock £66
RBC-AM-S54E-ES
Premium wired remote controller with 7-day time clock £105
RBC-AS41E Simplified wired remote controller £70
RBC-AX-32U(W)-E Infrared remote controller kit £151
TCB-PCNT-30TLE2
Network adapter for connection to central controllers £78
AMP-TRF Adapter for run/fault (12V DC output) £16
AMP-TRFVF Adapter for run/fault (volt free) £68
AMP-TRFVF+ Adapter for run/fault (volt free) with 24V DC on/off £110
*System princes include these as standard.
The Digital Inverter series of cassettes are unobtrusive and flexible which can easily blend in with any room interior. It is the ideal solution for applications where a ceiling void is present and easy access is required for maintenance and filter cleaning.
UTP-E 4-way compact cassette
ExistingPipe Sizes Allowable Outdoors
Liquid Gas Digital Inverter Super Digital Inverter
1/4" 1/2" 564, 804 564, 804
1/4" 5/8" 564, 804 564, 804
3/8" 1/2" 564, 804 564, 804
3/8" 5/8"564, 804, 1104,
1404, 1603564, 804, 1104,
1404
3/8" 3/4"804, 1104, 1404,
1603804, 1104, 1404
1/2" 5/8" 1104, 1404, 1603 1104, 1404
1/2" 3/4" 1104, 1404, 1603 1104, 1404Subject to the pipe sizes used and selected outdoor unit additional pipe work and
capacity, limitations may apply, see page 222 for further informationContact AMP for details.
@amp_aircon | amp-air-conditioning 44
RAV
Com
mer
cial
RAV Split Systems4 Way Cassettes Digital Inverter
Indoor Unit RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E
Grille RBC-U31PGP(W)-E RBC-U31PGP(W)-E RBC-U31PGP(W)-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM564ATP-E RAV-SM804ATP-E RAV-SM1104ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 5.0 (1.5 - 5.6) 6.7 (1.5 - 8.0) 10.0 (3.0 - 11.2)
UK Cooling (Total - Sensible) kW 5.0 - 3.5 6.4 - 4.2 9.5 - 7.6
Nominal Heating (Range) kW 5.3 (1.5 - 6.3) 7.7 (1.5 - 9.0) 11.2 (3.0 - 13.0)
UK Heating kW 3.8 5.5 8.0
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 6.14 - 4.51 5.81 - 4.05 5.87 - 4.28
Energy Efficiency Class (Cool / Heat) A++ / A+ A+ / A+ A+ / A+
EER - COP (Cool - Heat) 3.21 - 3.90 3.02 - 3.62 3.31 - 3.82
Energy Label (Cool / Heat) A / A B / A A / A
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 256 (30) - 840 (950) - 840 (950)
256 (30) - 840 (950) - 840 (950)
319 (30) - 840 (950) - 840 (950)
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 890 - 900 - 320
Weight (Indoor - Outdoor) kg 20 (4.2) - 40 20 (4.2) - 44 24 (4.2) - 68
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 217 - 242 - 292 225 - 267 - 342 325 - 400 - 558
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 28 - 29 - 32 28 - 31 - 35 33 - 38 - 43
Outdoor Sound Pressure (cool-heat) dB(A) 46 - 48 48 - 52 53 - 54
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 30 - 30 50 - 30
Pre-charged for m 20 20 30
Charge R410A (Factory - Additional) kg 1.1kg - 20g/m 1.7kg - 40g/m 2.8kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 7.31 - 6.37 10.40 - 9.98 14.60 - 14.17
Power Consumption (Cool - Heat) kW 1.56 - 1.36 2.22 - 2.13 3.02 - 2.93
Suggested Fuse Size A 16 - 12.3 20 - 14.3 25 - 20.8
Indoor Unit £610 £708 £793
Grille / Spigot Kit £154 £154 £154
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £840 £1,177 £1,549
Retail Price £1,670 £2,105 £2,562Lift pump as standard, 850mm from the underside of the ceiling tile| Knock out for branch duct 105 x 105 | Knock out for fresh air intake 57 x 64.
ampair.co.uk | 01707 378 670 | [email protected] 45
RAV
Com
mer
cial
RAV Split Systems4 Way Cassettes Digital Inverter
Indoor Unit RAV-SM1404UTP-E RAV-SM1604UTP-E
Grille RBC-U31PGP(W)-E RBC-U31PGP(W)-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM1404ATP-E RAV-SM1603AT-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 12.1 (3.0 - 13.2) 14.0 (3.0 - 16.0)
UK Cooling (Total - Sensible) kW 11.4 - 9.1 13.3 - 9.4
Nominal Heating (Range) kW 12.8 (3.0 - 16.0) 16.0 (3.0 - 18.0)
UK Heating kW 9.1 10.4
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.36 - 4.19 5.47 - 4.47
Energy Efficiency Class (Cool / Heat) A / A+ A / A
EER - COP (Cool - Heat) 2.80 - 3.76 3.12 - 3.61
Energy Label (Cool / Heat) D / A B / A
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 319 (30) - 840 (950) - 840 (950) 319 (30) - 840 (950) - 840 (950)
Outdoor Unit Dimensions (H-W-D) mm 890 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 24 (4.2) - 68 24 (4.2) - 99
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 342 - 400 - 583 350 - 417 - 592
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 34 - 38 - 44 36 - 40 - 45
Outdoor Sound Pressure (cool-heat) dB(A) 54 - 55 51 - 53
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 50 - 30 50 - 30
Pre-charged for m 30 30
Charge R410A (Factory - Additional) kg 2.8kg - 40g/m 3.1kg - 40g/m
Suitable for Replacement Tech. yes yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 20.74 - 16.44 21.48 - 21.20
Power Consumption (Cool - Heat) kW 3.57 - 3.40 4.49 - 4.43
Suggested Fuse Size A 25 - 22.8 32 - 29.7
Indoor Unit £815 £887
Grille / Spigot Kit £154 £154
Remote Controller inc. Time Clock £66 £66
Outdoor Unit £1,633 £2,059
Retail Price £2,668 £3,166Lift pump as standard, 850mm from the underside of the ceiling tile| Knock out for branch duct 105 x 105 | Knock out for fresh air intake 57 x 64.
@amp_aircon | amp-air-conditioning 46
RAV
Com
mer
cial
Indoor Unit RAV-SM564UTP-E RAV-SM804UTP-E
Grille RBC-U31PGP(W)-E RBC-U31PGP(W)-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP564ATP-E RAV-SP804ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 5.3 (1.2 - 5.6) 7.1 (1.9 - 8.0)
UK Cooling (Total - Sensible) kW 5.0 - 3.5 6.7 - 4.5
Nominal Heating (Range) kW 5.6 (0.9 - 8.1) 8.0 (1.3 - 11.3)
UK Heating kW 3.6 5.2
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 6.17 - 4.58 6.39 - 4.19
Energy Efficiency Class (Cool / Heat) A++ / A+ A++ / A+
EER - COP (Cool - Heat) 3.61 - 4.63 3.82 - 4.19
Energy Label (Cool / Heat) A / A A / A
AMBI
ENT
RAN
GE Cooling °C 43°C to -15°C
Heating °C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 256 (30) - 840 (950) - 840 (950) 256 (30) - 840 (950) - 840 (950)
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 890 - 900 - 320
Weight (Indoor - Outdoor) kg 20 (4.2) - 44 20 (4.2) - 66
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 217 - 242 - 292 225 - 267 - 342
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 28 - 29 - 32 28 - 31 - 35
Outdoor Sound Pressure (cool-heat) dB(A) 47 - 48 48 - 49
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 50 - 30 50 - 30
Pre-charged for m 20 30
Charge R410A (Factory - Additional) kg 1.4kg - 20g/m 2.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 6.82 - 5.61 8.72 - 8.95
Power Consumption (Cool - Heat) kW 1.47 - 1.21 1.86 - 1.91
Suggested Fuse Size - Max. Current A 16 - 13.3 25 - 20.3
Indoor Unit £610 £708
Grille / Spigot Kit £154 £154
Remote Controller inc. Time Clock £66 £66
Outdoor Unit £1,097 £1,628
Retail Price £1,927 £2,556
Lift pump as standard, 850mm from the underside of the ceiling tile | Knock out for branch duct 105 x 105 | knock out for fresh air intake 57 x 64.
RAV Split Systems4 Way Cassettes Super Digital Inverter Single Phase
ampair.co.uk | 01707 378 670 | [email protected] 47
RAV
Com
mer
cial
Indoor Unit RAV-SM1104UTP-E RAV-SM1404UTP-E
Grille RBC-U31PGP(W)-E RBC-U31PGP(W)-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT-E RAV-SP1404AT-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 10.0 (2.6 - 12.0) 12.5 (2.6 - 14.0)
UK Cooling (Total - Sensible) kW 9.5 - 7.6 11.9 - 9.5
Nominal Heating (Range) kW 11.2 (2.4 - 13.0) 14.0 (2.4 - 16.5)
UK Heating kW 7.3 9.1
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 6.60 - 4.28 5.36 - 4.19
Energy Efficiency Class (Cool / Heat) A++ / A+ A / A+
EER - COP (Cool - Heat) 4.52 - 4.79 3.96 - 4.36
Energy Label (Cool / Heat) A / A A / A
AMBI
ENT
RAN
GE Cooling °C 43°C to -15°C
Heating °C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 319(30)- 840(950)- 840(950) 319(30)- 840(950)- 840(950)
Outdoor Unit Dimensions (H-W-D) mm 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 24 (4.2) - 93 24 (4.2) - 93
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 325 - 400 - 558 342 - 400 - 583
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 33 - 38 - 43 34 - 38 - 44
Outdoor Sound Pressure (cool-heat) dB(A) 49 - 50 51 - 52
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 75 - 30 75 - 30
Pre-charged for m 30 30
Charge R410A (Factory - Additional) kg 3.1kg - 40g/m 3.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 10.36 - 10.96 14.66 - 14.89
Power Consumption (Cool - Heat) kW 2.21 - 2.34 3.16 - 3.21
Suggested Fuse Size - Max. Current A 25 - 20.5 25 - 20.5
Indoor Unit £793 £815
Grille / Spigot Kit £154 £154
Remote Controller inc. Time Clock £66 £66
Outdoor Unit £1,995 £2,205
Retail Price £3,008 £3,240
Lift pump as standard, 850mm from the underside of the ceiling tile | Knock out for branch duct 105 x 105 | knock out for fresh air intake 57 x 64.
RAV Split Systems4 Way Cassettes Super Digital Inverter Single Phase
@amp_aircon | amp-air-conditioning 48
RAV
Com
mer
cial
RAV Split Systems4 Way Cassettes Super Digital Inverter Three Phase
Indoor Unit RAV-SM1104UTP-E RAV-SM1404UTP-E RAV-SM1604UTP-E
Grille RBC-U31PGP(W)-E RBC-U31PGP(W)-E RBC-U31PGP(W)-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT8-E RAV-SP1404AT8-E RAV-SP1604AT8-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 10.0 (2.6 - 12.0) 12.5 (2.6 - 14.0) 14.0 (2.6 - 16.0)
UK Cooling (Total - Sensible) kW 9.7 - 7.4 12.1 - 8.4 13.5 - 9.0
Nominal Heating (Range) kW 11.2 (2.4 - 15.6) 14.0 (2.4 - 18.0) 16.0 (2.4 - 19.0)
UK Heating kW 7.3 9.1 10.4
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 6.57 - 4.28 5.87 - 4.86 5.49 - 4.73
Energy Efficiency Class (Cool / Heat) A++ / A++ A+ / A++ A / A++
EER - COP (Cool - Heat) 4.22 - 4.63 3.61 - 4.09 3.12 - 3.72
Energy Label (Cool / Heat) A / A A / A B / A
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 319 (30) - 840 (950) - 840 (950)
319 (30) - 840 (950) - 840 (950)
319 (30) - 840 (950) - 840 (950)
Outdoor Unit Dimensions (H-W-D) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 24 (4.2) - 95 24 (4.2) - 95 24 (4.2) - 95
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 325 - 400 - 558 342 - 400 - 583 350 - 417 - 592
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 33 - 38 - 43 34 - 38 - 44 36 - 40 -45
Outdoor Sound Pressure (cool-heat) dB(A) 49 - 50 51 - 52 51 - 53
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 75 - 30 75 - 30 75 - 30
Pre-charged for m 30 30 30
Charge R410A (Factory - Additional) kg 3.1kg - 40g/m 3.1kg - 40g/m 3.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 4.54 - 4.52 per phase 6.03 - 5.97 per phase 7.55 - 7.26 per phase
Power Consumption (Cool - Heat) kW 2.37 - 2.42 3.46 - 3.42 4.49 - 4.30
Suggested Fuse Size - Max. Current A 20 - 14.7 per phase 20 - 14.7 per phase 20 - 14.7 per phase
Indoor Unit £793 £815 £887
Grille / Spigot Kit £154 £154 £154
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £2,184 £2,279 £2,426
Retail Price £3,197 £3,314 £3,533
Lift pump as standard, 850mm from the underside of the ceiling tile | Knock out for branch duct 105 x 105 | Knock out for fresh air intake 57 x 64.
ampair.co.uk | 01707 378 670 | [email protected] 49
RAV
Com
mer
cial
RAV Split SystemsSDT-E Slim Ducted
» High efficiency twin rotary inverter compressor» Replacement technology (R22 & R407c)» Slim 210mm deep ducted unit design» Rear or underside return air» Static pressure up to 50Pa» Extremely quiet operation
» Twin split also available» Infrared and wired control options available» Operational to -15°C in cooling and heating
Digital Inverter Outdoor UnitSDT-E Slim Ducted Indoor Unit
Compatible Accessories
Part No. Description ListPrice
RBC-AMT32E Wired Remote Controller £50
RBC-AM-S41E*
Wired remote controller with 7-day time clock £66
RBC-AM-S54E-ES
Premium wired remote controller with 7-day time clock £105
RBC-AS41E Simplified wired remote controller £70
RCB-AX32E2 Infrared remote controller kit £214
TCB-TC41LE Remote return air sensor £64
TCB-PCNT-30TLE2
Network adapter for connection to central controllers £78
AMP-TRF Adapter for run/fault (12V DC output) £16
AMP-TRFVF Adapter for run/fault (volt free) £68
AMP-TRFVF+ Adapter for run/fault (volt free) with 24V DC on/off £110
*System princes include these as standard .
The slim ducted unit is very compact with low height dimensions for flexible ceiling instillations.
ExistingPipe Sizes Allowable Outdoors
Liquid Gas Digital Inverter Super Digital Inverter
1/4" 3/8" 304, 404 404
1/4" 1/2" 304, 404, 564 404, 564
1/4" 5/8" 404, 564 404, 564
3/8" 3/8" 304
3/8" 1/2" 304, 404, 564 404, 564
3/8" 5/8" 404, 564 404, 564
Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information
Contact AMP for details.
@amp_aircon | amp-air-conditioning 50
RAV
Com
mer
cial
Indoor Unit RAV-SM304SDT-E RAV-SM404SDT-E RAV-SM564SDT-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM304ATP-E RAV-SM404ATP-E RAV-SM564ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 2.5 (0.9 - 3.0) 3.6 (0.9 - 4.0) 5.0 (1.5 - 5.6)
UK Cooling (Total - Sensible) kW 2.40 - 1.97 3.45 - 2.84 4.8 - 3.3
Nominal Heating (Range) kW 3.4 (0.8 - 4.5) 4.0 (0.8 - 5.0) 5.3 (1.5 - 6.3)
UK Heating kW 2.18 2.56 3.79
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 6.10 - 4.48 5.55 - 3.88 5.06 - 4.06
Energy Efficiency Class (Cool / Heat) A++ / A+ A / A B / A+
EER - COP (Cool - Heat) 4.46 - 3.95 3.87 - 4.12 2.62 - 3.53
Energy Label (Cool / Heat) TBC TBC D / B
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C 46°C to -15°C
Heating °C 24°C to -15°C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 210 - 845 - 645 210 - 845 - 645 210 - 845 - 645
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 22 - 33 22 - 39 22 - 40
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 133 - 155 - 183 145 - 167 - 192 162 - 188 - 217
Static Pressure (standard-upper) Pa 10 - 50 10 - 50 4 - 50
Discharge Spigots Rectangular Outlet Rectangular Outlet Rectangular Outlet
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 26 - 28 - 30* 26 - 28 - 30* 28 - 31 - 33*
Outdoor Sound Pressure (cool-heat) dB(A) 46 - 47 49 - 50 46 - 48
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 3/8" - 1/4" 1/2" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 20 - 10 20 - 10 30 - 30
Pre-charged for m 15 15 20
Charge R410A (Factory - Additional) kg 0.8kg - 20g/m 1.4kg - 20g/m 1.1kg - 20g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 3.91 4.41 8.95 - 7.03
Power Consumption (Cool - Heat) kW 0.56 - 0.86 0.93 - 0.97 1.91 - 1.50
Suggested Fuse Size - Max. Current A 10 - TBC 10 - TBC 16 - 13.6
Indoor Unit £467 £507 £518
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £588 £704 £840
Retail Price £1,121 £1,277 £1,424
Rear or bottom return | * Sound pressure levels are for rear return, bottom return have higher sound pressure levels.
RAV Split SystemsSlim Ducted Digital Inverter
ampair.co.uk | 01707 378 670 | [email protected] 51
RAV
Com
mer
cial
Indoor Unit RAV-SM404SDT-E RAV-SM564SDT-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP404ATP-E RAV-SP564ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 3.6 5.0
UK Cooling (Total - Sensible) kW 3.4 - 2.6 4.8 - 3.5
Nominal Heating (Range) kW 4.0 5.6
UK Heating kW 2.6 3.7
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.11 - 3.90 5.10 - 3.83
Energy Efficiency Class (Cool / Heat) A / A A / A
EER - COP (Cool - Heat) 3.50 - 4.00 3.21 - 3.89
Energy Label (Cool / Heat) A / A A / A
AMBI
ENT
RAN
GE Cooling °C 43°C to -15°C 43°C to -15°C
Heating °C 15°C to -15°C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 210 - 845 - 645 210 - 845 - 645
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 22 - 40 22 - 44
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 145 - 167 - 192 162 - 188 - 217
Static Pressure (Upper) Pa 50 50
Discharge Spigots Rectangular Outlet Rectangular Outlet
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 26 - 28 - 30* 28 - 31 - 33*
Outdoor Sound Pressure (cool-heat) dB(A) 45 - 47 47 - 48
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 50 - 30
Pre-charged for m 20 20
Charge R410A (Factory - Additional) kg 1.0kg - 20g/m 1.4kg - 20g/m
Suitable for Replacement Tech. Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 5.05 - 4.79 7.24 - 7.14
Power Consumption (Cool - Heat) kW 1.00 - 0.97 1.56 - 1.54
Suggested Fuse Size - Max. Current A 20 - 15.0 16 - 13.6
Indoor Unit £507 £518
Remote Controller inc. Time Clock £66 £66
Outdoor Unit £998 £1,097
Retail Price £1,571 £1,681
Rear or bottom return | * Sound pressure levels are for rear return, bottom return have higher sound pressure levels.
RAV Split SystemsSlim Ducted Super Digital Inverter
Optional ControllerRBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 52
RAV
Com
mer
cial
RAV Split SystemsBTP-E Standard Ducted
» Unobtrusive installation above suspended ceilings» High performance operation» Infrared and wired control options available» High static pressure up to 120Pa» High-lift drain pump kit to 550mm» Uniform temperatures throughout the room» Extremely quiet operation» Ideal for R22 & R407c replacement
DI twin fan outdoor unit
Compatible Accessories
Part No. Description ListPrice
RBC-AMT32E Wired Remote Controller £50
RBC-AMS41E*
Wired remote controller with 7-day time clock £66
RBC-AMS54E-ES
Premium wired remote controller with 7-day time clock £105
RBC-AS41E Simplified wired remote controller £70
TCB-AX32E2 Infrared remote controller kit £214
TCB-TC41LE Remote return air sensor £64
TCB-PCNT30TLE2
Network adapter for connection to central controllers £78
AMP-TRF Adapter for run/fault (12V DC output) £16
AMP-TRFVF Adapter for run/fault (volt free) £68
AMP-TRFVF+ Adapter for run/fault (volt free) with 24V DC on/off £110
*System princes include these as standard.
The Digital Inverter series of ducted units can be discreetly positioned in the ceiling. They are ideal for hotels, banks and similar applications where very low noise levels are needed.
BTP-E Standard Ducted Unit
ExistingPipe Sizes Allowable Outdoors
Liquid Gas Digital Inverter Super Digital Inverter
1/4" 3/8" 404 404
1/4" 1/2" 404, 564, 804 404, 564, 804
1/4" 5/8" 404, 564, 804 404, 564, 804
3/8" 1/2" 404, 564, 804 404, 564, 804
3/8" 5/8" 404, 564, 804, 1104, 1404, 1603
404, 564, 804, 1104, 1404
3/8" 3/4" 804, 1104, 1404, 1603 804, 1104, 1404
1/2" 5/8" 1104, 1404, 1603 1104, 1404
1/2" 3/4" 1104, 1404, 1603 1104, 1404
Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information
Contact AMP for details.
ampair.co.uk | 01707 378 670 | [email protected] 53
RAV
Com
mer
cial
RAV Split SystemsStandard Ducted Digital Inverter
Indoor Unit RAV-SM406BTP-E RAV-SM566BTP-E RAV-SM806BTP-E
Spigot Kit AMP-RAVBTE-2DUCT AMP-RAVBTE-2DUCT AMP-RAVBTE-3DUCT
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM404ATP-E RAV-SM564ATP-E RAV-SM804ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 3.6 (TBC) 5.0 (1.5 - 5.6) 6.7 (1.5 - 7.4)
UK Cooling (Total - Sensible) kW TBC 4.8 - 3.6 6.2 - 4.8
Nominal Heating (Range) kW 4.0 (TBC) 5.3 (1.5 - 6.3) 7.7 (1.5 - 9.0)
UK Heating kW TBC 3.8 5.5
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.06 - 3.95 4.80 - 3.98 5.04 - 3.83
Energy Efficiency Class (Cool / Heat) B / A B / A B / A+
EER - COP (Cool - Heat) TBC 2.73 - 3.27 2.82 - 3.32
Energy Label (Cool / Heat) TBC D / C C / C
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 275 - 700 - 750 275 - 700 - 750 275 - 1000 - 750
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 23 - 39 23 - 40 30 - 44
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s TBC 133 - 175 - 222 200 - 258 - 333
Static Pressure (standard-upper) Pa TBC 30 - 120 30 - 120
Discharge Spigots 2 x 200mm 2 x 200mm 3 x 200mm
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 25 - 29 - 33 25 - 29 - 33 26 - 30 - 34
Outdoor Sound Pressure (cool-heat) dB(A) 45 - 47 46 - 48 48 - 52
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 1/2" - 1/4" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 20 - 10 30 - 30 30 - 30
Pre-charged for m 15 20 20
Charge R410A (Factory - Additional) kg 1.4kg - 20g/m 1.1kg - 20g/m 1.7kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm TBC VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A TBC 8.58 - 7.59 11.15 - 10.87
Power Consumption (Cool - Heat) kW TBC 1.83 - 1.62 2.38 - 2.32
Suggested Fuse Size - Max. Current A 10 - TBC 16 - 12.9 20 - 15.4
Indoor Unit £528 £588 £843
Spigot Kit £40 £40 £54
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £704 £840 £1,177
Retail Price £1,338 £1,534 £2,140
Lift pump as standard, 550mm from the underside of the unit | Bottom return as standard, rear return possible.
@amp_aircon | amp-air-conditioning 54
RAV
Com
mer
cial
RAV Split SystemsStandard Ducted Digital Inverter
Indoor Unit RAV-SM1106BTP-E RAV-SM1406BTP-E RAV-SM1606BTP-E
Spigot Kit AMP-RAVBTE-4DUCT AMP-RAVBTE-4DUCT AMP-RAVBTE-4DUCT
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM1104ATP-E RAV-SM1404ATP-E RAV-SM1603AT-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 10.0 (3.0 - 11.2) 12.1 (3.0 - 13.2) 14.0 (3.0 - 16.0)
UK Cooling (Total - Sensible) kW 9.5 - 7.7 11.5 - 8.9 13.3 - 9.3
Nominal Heating (Range) kW 11.2 (3.0 - 12.5) 12.8 (3.0 - 16.0) 16.0 (3.0 - 18.0)
UK Heating kW 8.0 9.2 10.5
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.03 - 4.14 5.53 - 4.42 4.78 - 3.89
Energy Efficiency Class (Cool / Heat) B / A+ A / A+ B / A
EER - COP (Cool - Heat) 3.18 - 3.75 2.74 - 3.61 2.73 - 3.41
Energy Label (Cool / Heat) B / A D / A D / B
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 275 - 1400 - 750 275 - 1400 - 750 275 - 1400 - 750
Outdoor Unit Dimensions (H-W-D) mm 890 - 900 - 320 890 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 40 - 68 40 - 68 40 - 99
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 350 - 458 - 583 350 - 458 - 583 350 - 458 - 583
Static Pressure (standard-upper) Pa 50 - 120 50 - 120 50 - 120
Discharge Spigots 4 x 200mm 4 x 200mm 4 x 200mm
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 33 - 36 - 40 33 - 36 - 40 33 - 36 - 40
Outdoor Sound Pressure (cool-heat) dB(A) 53 - 54 54 - 55 51 - 53
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 50 - 30 50 - 30 50 - 30
Pre-charged for m 30 30 30
Charge R410A (Factory - Additional) kg 2.8kg - 40g/m 2.8kg - 40g/m 3.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 15.18 - 14.46 21.37 - 17.17 24.54 - 22.44
Power Consumption (Cool - Heat) kW 3.14 - 2.99 4.42 - 3.55 5.13 - 4.69
Suggested Fuse Size - Max. Current A 25 - 22.0 25 - 22.8 TBC - TBC
Indoor Unit £964 £1,076 £1,174
Spigot Kit £67 £67 £67
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £1,549 £1,633 £2,059
Retail Price £2,646 £2,841 £3,366
Lift pump as standard, 550mm from the underside of the unit | Bottom return as standard, rear return possible.
ampair.co.uk | 01707 378 670 | [email protected] 55
RAV
Com
mer
cial
RAV Split SystemsStandard Ducted Super Digital Inverter Single Phase
Indoor Unit RAV-SM406BTP-E RAV-SM566BTP-E RAV-SM806BTP-E
Spigot Kit AMP-RAVBTE-2DUCT AMP-RAVBTE-2DUCT AMP-RAVBTE-3DUCT
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP404ATP-E RAV-SP564ATP-E RAV-SP804ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 3.6 (1.5 - 4.0) 5.0 (1.2 - 5.6) 7.1 (1.9 - 8.0)
UK Cooling (Total - Sensible) kW 3.4 - 3.0 4.8 - 3.6 6.7 - 5.1
Nominal Heating (Range) kW 4.0 (1.5 - 5.0) 5.6 (0.9 - 7.4) 8.0 (1.3 - 10.6)
UK Heating kW 2.6 3.7 5.2
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.10 - 4.02 4.88 - 4.01 5.88 - 4.00
Energy Efficiency Class (Cool / Heat) A / A+ B / A+ A+ / A+
EER - COP (Cool - Heat) 3.38 - 3.84 3.21 - 3.61 3.45 - 3.62
Energy Label (Cool / Heat) A / A A / A A / A
AMBI
ENT
RAN
GE Cooling °C 43°C to -15°C 43°C to -15°C
Heating °C 15°C to -15°C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 275 - 700 - 750 275 - 700 - 750 275 - 1000 - 750
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 890 - 900 - 320
Weight (Indoor - Outdoor) kg 23 - 40 23 - 44 30 - 66
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 133 - 175 - 222 133 - 175 - 222 200 - 258 - 333
Static Pressure (standard-upper) Pa 30 - 120 30 - 120 30 - 120
Discharge Spigots 2 x 200mm 2 x 200mm 3 x 200mm
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 25 - 29 - 33 25 - 29 - 33 26 - 30 - 34
Outdoor Sound Pressure (cool-heat) dB(A) 45 - 47 47 - 48 48 - 49
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 1/2" - 1/4" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 50 - 30 50 - 30
Pre-charged for m 20 20 30
Charge R410A (Factory - Additional) kg 1.0kg - 20g/m 1.4kg - 20g/m 2.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 5.40 - 5.13 7.23 - 7.18 9.65 - 10.30
Power Consumption (Cool - Heat) kW 1.07 - 1.04 1.56 - 1.55 2.06 - 2.21
Suggested Fuse Size - Max. Current A 16 - 11.2 16 - 13.7 25 - 20.7
Indoor Unit £528 £588 £843
Spigot Kit £40 £40 £54
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £998 £1,097 £1,628
Retail Price £1,632 £1,791 £2,591
Lift pump as standard, 550mm from the underside of the unit | Bottom return as standard, rear return possible.
@amp_aircon | amp-air-conditioning 56
RAV
Com
mer
cial
Indoor Unit RAV-SM1106BTP-E RAV-SM1406BTP-E
Spigot Kit AMP-RAVBTE-4DUCT AMP-RAVBTE-4DUCT
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT-E RAV-SP1404AT-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 10.0 (2.6 - 12.0) 12.5 (2.6 - 14.0)
UK Cooling (Total - Sensible) kW 9.7 - 7.2 12.1 - 9.0
Nominal Heating (Range) kW 11.2 (2.4 - 13.0) 14.0 (2.4 - 16.5)
UK Heating kW 7.3 9.1
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.65 - 3.87 5.22 - 4.03
Energy Efficiency Class (Cool / Heat) A+ / A A / A+
EER - COP (Cool - Heat) 3.79 - 4.04 3.26 - 3.81
Energy Label (Cool / Heat) A / A A / A
AMBI
ENT
RAN
GE Cooling °C 43°C to -15°C
Heating °C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 275 - 1400 - 750 275 - 1400 - 750
Outdoor Unit Dimensions (H-W-D) mm 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 40 - 93 40 - 93
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 350 - 458 - 583 350 - 458 - 583
Static Pressure (standard-upper) Pa 50 - 120 50 - 120
Discharge Spigots 4 x 200mm 4 x 200mm
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 33 - 36 - 40 33 - 36 - 40
Outdoor Sound Pressure (cool-heat) dB(A) 49 - 50 51 - 52
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 75 - 30 75 - 30
Pre-charged for m 30 30
Charge R410A (Factory - Additional) kg 3.1kg - 40g/m 3.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 12.30 - 12.90 TBC
Power Consumption (Cool - Heat) kW 2.64 - 2.77 TBC
Suggested Fuse Size - Max. Current A 25 - 22.3 25 - 22.6
Indoor Unit £964 £1,076
Spigot Kit £67 £67
Remote Controller inc. Time Clock £66 £66
Outdoor Unit £1,995 £2,205
Retail Price £3,092 £3,414
Lift pump as standard, 550mm from the underside of the unit | Bottom return as standard, rear return possible.
RAV Split SystemsStandard Ducted Super Digital Inverter Single Phase
ampair.co.uk | 01707 378 670 | [email protected] 57
RAV
Com
mer
cial
RAV Split SystemsStandard Ducted Super Digital Inverter Three Phase
Indoor Unit RAV-SM1106BTP-E RAV-SM1406BTP-E RAV-SM1606BTP-E
Spigot Kit AMP-RAVBTE-4DUCT AMP-RAVBTE-4DUCT AMP-RAVBTE-4DUCT
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT8-E RAV-SP1404AT8-E RAV-SP1604AT8-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 10.0 (2.6 - 12.0) 12.5 (2.6 - 14.0) 14.0 (2.6 - 16.0)
UK Cooling (Total - Sensible) kW 9.7 - 7.2 12.1 - 9.0 13.5 - 10.1
Nominal Heating (Range) kW 11.2 (2.4 - 15.6) 14.0 (2.4 - 18.0) 16.0 (2.4 - 19.0)
UK Heating kW 7.3 9.1 10.5
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.65 - 3.87 5.09 - 4.48 4.97 - 4.35
Energy Efficiency Class (Cool / Heat) A+ / A B / A+ B / A+
EER - COP (Cool - Heat) 3.79 - 4.04 3.24 - 3.81 3.01 - 3.48
Energy Label (Cool / Heat) A / A A / A B / B
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 275 - 1400 - 750 275 - 1400 - 750 275 - 1400 - 750
Outdoor Unit Dimensions (H-W-D) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 40 - 95 40 - 95 40 - 95
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 350 - 458 - 583 350 - 458 - 583 350 - 458 - 583
Static Pressure (standard-upper) Pa 50 - 120 50 - 120 50 - 120
Discharge Spigots 4 x 200mm 4 x 200mm 4 x 200mm
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 33 - 36 - 40 33 - 36 - 40 33 - 36 - 40
Outdoor Sound Pressure (cool-heat) dB(A) 49 - 50 51 - 52 51 - 53
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 75 - 30 75 - 30 75 - 30
Pre-charged for m 30 30 30
Charge R410A (Factory - Additional) kg 3.1kg - 40g/m 3.1kg - 40g/m 3.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP25 (25id 32od) VP25 (25id 32od) VP25 (25id 32od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 3.72 per phase 5.42 per phase 6.66 per phase
Power Consumption (Cool - Heat) kW 2.64 - 2.77 3.86 - 3.67 4.65 - 4.60
Suggested Fuse Size- Max. Current A 20 - 16.2 per phase 20 - 16.5 per phase 20 - 16.9 per phase
Indoor Unit £964 £1,076 £1,174
Spigot Kit £67 £67 £67
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £2,184 £2,279 £2,426
Retail Price £3,281 £3,488 £3,733
Lift pump as standard, 850mm from the underside of the ceiling tile | Knock out for branch duct | Knock out for fresh air intake.
@amp_aircon | amp-air-conditioning 58
RAV
Com
mer
cial
RAV Split SystemsDT-E High Static Ducted
» Maximum external static pressure 196Pa» 3 stage selectable static pressure setting» Digital inverter large outdoor unit» Ideal for larger shops and retail premises» Outdoor unit 400V, 3 phase supply» High efficiency twin rotary inverter compressor» Space saving small footprint
RAV-SM2804AT8-E outdoor unit
Compatible Accessories
Part No. Description ListPrice
RBC-AMT32E Wired Remote Controller £50
RBC-AMS41E*
Wired remote controller with 7-day time clock £66
RBC-AMS54E-ES
Premium wired remote controller with 7-day time clock £105
RBC-AS41E Simplified wired remote controller £70
TCB-AX32E2 Infrared remote controller kit £214
TCB-TC41LE Remote return air sensor £64
TCB-PCNT30TLE2
Network adapter for connection to central controllers £78
AMP-TRF Adapter for run/fault (12V DC output) £16
AMP-TRFVF Adapter for run/fault (volt free) £68
AMP-TRFVF+ Adapter for run/fault (volt free) with 24V DC on/off £110
*System princes include these as standard.
This range of units has been designed to provide a high capacity output from a very small footprint.
DT-E high static ducted
ExistingPipe Sizes Allowable Outdoors
Liquid Gas Digital Inverter Super Digital Inverter
1/2" 7/8" 2244, 2804
1/2" 1 1/8" 2244, 2804
5/8" 7/8" 2244, 2804
5/8" 1 1/8" 2244, 2804
Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information
Contact AMP for details.
ampair.co.uk | 01707 378 670 | [email protected] 59
RAV
Com
mer
cial
RAV Split SystemsHigh Static Ducted Digital Inverter
Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 20.0 (9.8 - 22.4) 23.0 (9.8 - 27.0)
UK Cooling (Total - Sensible) kW 19.3 - 15.0 22.2 - 16.7
Nominal Heating (Range) kW 22.4 (9.8 - 25.0) 27.0 (9.8 - 31.5)
UK Heating kW 14.60 17.60
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 4.15 - 4.11 4.51 - 3.98
Energy Efficiency Class (Cool / Heat) C / A+ C / A
EER - COP (Cool - Heat) 2.78 - 3.45 2.63 - 3.31
Energy Label (Cool / Heat) D / B D / C
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 470 - 1380 - 1250 470 - 1380 - 1250
Outdoor Unit Dimensions (H-W-D) mm 1540 - 900 - 320 1540 - 900 - 320
Weight (Indoor - Outdoor) kg 160 - 134 160 - 134
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 1000 1167
Static Pressure (standard-upper) Pa 68.6 - 137.0 - 196.0 68.6 - 137.0 - 196.0
Discharge Spigots Rectangular Outlet Rectangular Outlet
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 54 55
Outdoor Sound Pressure (cool-heat) dB(A) 56 - 57 57 - 58
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1 1/8" - 1/2" 1 1/8" - 1/2"
Pipe Limits (Max Run - Height Diff.) m 70 - 30 70 - 30
Pre-charged for m 30 30
Charge R410A (Factory - Additional) kg 5.9kg - 80g/m 5.9kg - 80g/m
Suitable for Replacement Tech. Yes Yes
Indoor Drain Connection mm 32 (VP25 (25id 32od)) 32 (VP25 (25id 32od))
POW
ER
Power Supply (Outdoor) V-Ph-Hz 400 - 3 - 50 & indoor 230- 1 -50 400 - 3 - 50 & indoor 230- 1 -50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A Outdoor 18.0A - indoor 15.0A Outdoor 20.0A - indoor 15.0A
Power Consumption (Cool - Heat) kW 7.20 - 6.49 8.75 - 8.15
Suggested Fuse Size A Outdoor 25A per phase - indoor 20A Outdoor 32A per phase - indoor 20A
Indoor Unit £2,622 £2,826
Remote Controller inc. Time Clock £66 £66
Outdoor Unit £3,000 £3,095
Retail Price £5,688 £5,987
Optional ControllerRBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 60
RAV
Com
mer
cial
RAV Split SystemsCTP-E Ceiling Suspended
» Easy installation and maintenance
» High performance operation, using digital inverter control
» Infrared and wired controls available» Low noise levels» Ideal for R22 and R407c replacement
» Automatic louver control for colling and heating models plus auto-swing
Digital inverter single fan outdoor unitCTP-E ceiling suspended unit
Compatible Accessories
Part No. Description ListPrice
RBC-AMT32E Wired Remote Controller £50
RBC-AM-S41E*
Wired remote controller with 7-day time clock £66
RBC-AM-S54E-ES
Premium wired remote controller with 7-day time clock £105
RBC-AS41E Simplified wired remote controller £70
RBC-AX33CE Infrared remote controller kit £166
TCB-PCNT30TLE2
Network adapter for connection to central controllers £78
AMP-TRF Adapter for run/fault (12V DC output) £16
AMP-TRFVF Adapter for run/fault (volt free) £68
AMP-TRFVF+ Adapter for run/fault (volt free) with 24V DC on/off £110
*System princes include these as standard
The Digital Inverter series of ceiling suspended units can be discreetly positioned under the ceiling. They are ideal for offices, classrooms and restaurants.
ExistingPipe Sizes Allowable Outdoors
Liquid Gas Digital Inverter Super Digital Inverter
1/4" 3/8" 404 404
1/4" 1/2" 404, 564, 804 404, 564, 804
1/4" 5/8" 404, 564, 804 404, 564, 804
3/8" 1/2" 404, 564, 804 404, 564, 804
3/8" 5/8" 404, 564, 804, 1104, 1404, 1603
404, 564, 804, 1104, 1404
3/8" 3/4" 804, 1104, 1404, 1603 804, 1104, 1404
1/2" 5/8" 1104, 1404, 1603 1104, 1404
1/2" 3/4" 1104, 1404, 1603 1104, 1404
Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information
Contact AMP for details.
ampair.co.uk | 01707 378 670 | [email protected] 61
RAV
Com
mer
cial
RAV Split SystemsCeiling Suspended Digital Inverter
Indoor Unit RAV-SM407CTP-E RAV-SM567CTP-E RAV-SM807CTP-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM404ATP-E RAV-SM564ATP-E RAV-SM804ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 3.6 (0.9 - 4.0) 5.0 (1.5 - 5.6) 6.9 (1.5 - 7.4)
UK Cooling (Total - Sensible) kW 3.45 - 2.89 4.8 - 3.6 6.6 - 5.0
Nominal Heating (Range) kW 4.0 (0.8 - 5.0) 5.3 (1.5 - 6.3) 7.7 (1.5 - 9.0)
UK Heating kW 2.56 3.8 5.5
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.96 - 4.98 5.41 - 4.21 5.62 - 4.01
Energy Efficiency Class (Cool / Heat) A+ / A++ A / A+ A+ / A+
EER - COP (Cool - Heat) 4.34 - 5.13 3.11 - 3.90 2.90 - 3.62
Energy Label (Cool / Heat) TBC B / A C / A
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C 46°C to -15°C
Heating °C 24°C to -15°C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 235 - 950 - 690 235 - 950 - 690 235 - 1270 - 690
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 23 - 39 23 - 40 29 - 44
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 150 - 200 - 250 150 - 200 - 250 208 - 278 - 392
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 28 - 35 - 37 28 - 35 - 37 29 - 36 - 41
Outdoor Sound Pressure (cool-heat) dB(A) 49 - 50 46 - 48 48 - 52
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 1/2" - 1/4" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 20 - 10 30 - 30 30 - 30
Pre-charged for m 15 20 20
Charge R410A (Factory - Additional) kg 1.4kg - 20g/m 1.1kg - 20g/m 1.7kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP20 VP20 (20id 26od) VP20 (20id 26od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 5.48 7.54 - 6.37 11.15 - 9.98
Power Consumption (Cool - Heat) kW 1.20 - 0.78 1.61 - 1.36 2.38 - 2.13
Suggested Fuse Size - Max. Current A 10 - TBC 16 - 12.8 20 - 15.1
Indoor Unit £604 £658 £779
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £704 £840 £1,177
Retail Price £1,374 £1,564 £2,022
Optional ControllerRBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 62
RAV
Com
mer
cial
RAV Split SystemsCeiling Suspended Digital Inverter
Indoor Unit RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM1607CTP-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM1104ATP-E RAV-SM1404ATP-E RAV-SM1603AT-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 10.0 (3.0 - 11.2) 12.1 (3.0 - 13.2) 14.0 (3.0 - 16.0)
UK Cooling (Total - Sensible) kW 9.5 - 7.2 11.5 - 8.4 13.3 - 9.3
Nominal Heating (Range) kW 11.2 (3.0 - 12.5) 12.8 (3.0 - 16.0) 16.0 (3.0 - 18.0)
UK Heating kW 8.0 9.1 10.4
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.79 - 4.27 5.53 - 4.55 4.94 - 4.36
Energy Efficiency Class (Cool / Heat) A+ / A+ A / A+ B / A+
EER - COP (Cool - Heat) 3.22 - 3.81 2.74 - 3.73 3.01 - 3.47
Energy Label (Cool / Heat) B / A D / A C / B
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -15°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 235 - 1586 - 690 235 - 1586 - 690 235 - 1586 - 690
Outdoor Unit Dimensions (H-W-D) mm 890 - 900 - 320 890 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 35 - 68 35 - 68 35 - 99
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 283 - 375 - 517 333 - 425 - 567 350 - 458 - 567
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 32 - 38 - 44 35 - 41 - 46 36 - 42 - 46
Outdoor Sound Pressure (cool-heat) dB(A) 53 - 54 54 - 55 51 - 53
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 50 - 30 50 - 30 50 - 30
Pre-charged for m 30 30 30
Charge R410A (Factory - Additional) kg 2.8kg - 40g/m 2.8kg - 40g/m 3.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP20 (20id 26od) VP20 (20id 26od) VP20 (20id 26od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 15.04 - 14.22 21.37 - 16.59 22.25 - 22.06
Power Consumption (Cool - Heat) kW 3.11 - 2.94 4.42 - 3.43 4.65 - 4.61
Suggested Fuse Size - Max. Current A 20 - 21.6 25 - 22.8 tbc - tbc
Indoor Unit £849 £1,071 £1,090
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £1,549 £1,633 £2,059
Retail Price £2,464 £2,770 £3,215
ampair.co.uk | 01707 378 670 | [email protected] 63
RAV
Com
mer
cial
RAV Split SystemsCeiling Suspended Super Digital Inverter Single Phase
Indoor Unit RAV-SM407CTP-E RAV-SM567CTP-E RAV-SM807CTP-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP404ATP-E RAV-SP564ATP-E RAV-SP804ATP-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 3.6 (TBC) 5.0 (1.2 - 5.6) 7.1 (1.9 - 8.0)
UK Cooling (Total - Sensible) kW TBC 4.8 - 3.6 6.7 - 5.1
Nominal Heating (Range) kW 4.0 (TBC) 5.6 (0.9 - 7.4) 8.0 (1.3 - 10.6)
UK Heating kW TBC 3.7 5.2
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 5.96 - 4.98 5.45 - 4.28 6.21 - 4.10
Energy Efficiency Class (Cool / Heat) A+ / A++ A / A+ A++ / A+
EER - COP (Cool - Heat) TBC 3.65 - 4.38 3.82 - 4.17
Energy Label (Cool / Heat) TBC A / A A / A
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C 43°C to -15°C
Heating °C 15°C to -15°C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 235 - 950 - 690 235 - 950 - 690 235 - 1270 - 690
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 890 - 900 - 320
Weight (Indoor - Outdoor) kg 23 - 40 23 - 44 29 - 66
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 150 - 200 - 250 150 - 200 - 250 208 - 278 - 392
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 28 - 35 - 37 28 - 35 - 37 29 - 36 - 41
Outdoor Sound Pressure (cool-heat) dB(A) 45 - 47 47 - 48 48 - 49
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 1/2" - 1/4" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 50 - 30 50 - 30
Pre-charged for m 15 20 30
Charge R410A (Factory - Additional) kg 1.0kg - 20g/m 1.4kg - 20g/m 2.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP20 VP20 (20id 26od) VP20 (20id 26od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A TBC 6.55 9.02
Power Consumption (Cool - Heat) kW TBC 1.37 - 1.28 1.86 - 1.92
Suggested Fuse Size - Max. Current A 20 16 - 13.6 25 - 20.6
Indoor Unit £604 £658 £779
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £998 £1,097 £1,628
Retail Price £1,668 £1,821 £2,473
Optional ControllerRBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 64
RAV
Com
mer
cial
RAV Split SystemsCeiling Suspended Super Digital Inverter Single Phase
Indoor Unit RAV-SM1107CTP-E RAV-SM1407CTP-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT-E RAV-SP1404AT-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 10.0 (2.6 - 12.0) 12.5 (2.6 - 14.0)
UK Cooling (Total - Sensible) kW 9.5 - 7.2 11.9 - 8.7
Nominal Heating (Range) kW 11.2 (2.4 - 13.0) 14.0 (2.4 - 18.0)
UK Heating kW 7.3 9.1
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 6.18 - 4.27 5.14 - 4.09
Energy Efficiency Class (Cool / Heat) A++ / A+ A / A+
EER - COP (Cool - Heat) 4.08 - 4.69 3.21 - 3.87
Energy Label (Cool / Heat) A / A A / A
AMBI
ENT
RAN
GE Cooling °C 43°C to -15°C
Heating °C 15°C to -20°C
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 235 - 1586 - 690 235 - 1586 - 690
Outdoor Unit Dimensions (H-W-D) mm 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 35 - 93 35 - 93
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 283 - 375 - 517 333 - 425 - 567
Static Pressure (standard-upper) Pa n/a n/a
Discharge Spigots n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 32 - 38 - 44 35 - 41 - 46
Outdoor Sound Pressure (cool-heat) dB(A) 49 - 50 51 - 52
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 75 - 30 75 - 30
Pre-charged for m 30 30
Charge R410A (Factory - Additional) kg 3.1kg - 40g/m 3.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes
Indoor Drain Connection mm VP20 (20id 26od) VP20 (20id 26od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Interconnecting Cables 3 core + E 3 core + E
Running Current (Cool - Heat) A 10.43 15.76
Power Consumption (Cool - Heat) kW 2.45 - 2.39 3.90 - 3.62
Suggested Fuse Size - Max. Current A 25 - 21.6 25 - 21.6
Indoor Unit £849 £1,071
Remote Controller inc. Time Clock £66 £66
Outdoor Unit £1,995 £2,205
Retail Price £2,910 £3,342
ampair.co.uk | 01707 378 670 | [email protected] 65
RAV
Com
mer
cial
RAV Split SystemsCeiling Suspended Super Digital Inverter Three Phase
Indoor Unit RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM1607CTP-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT8-E RAV-SP1404AT8-E RAV-SP1604AT8-E
PERF
ORM
ANCE
Nominal Cooling (Range) kW 10.0 (2.6 - 12.0) 12.5 (2.6 - 12.0) 14.0 (2.6 - 16.0)
UK Cooling (Total - Sensible) kW 9.5 - 7.2 11.9 - 8.7 13.3 - 9.3
Nominal Heating (Range) kW 11.2 (2.4 - 14.0) 14.0 (2.4 - 18.0) 16.0 (2.4 - 19.0)
UK Heating kW 7.3 9.1 10.4
EFFI
CIEN
CY
SEER - SCOP (Cool - Heat) 6.35 - 4.41 5.49 - 4.65 5.49 - 4.73
Energy Efficiency Class (Cool / Heat) A++ / A+ A / A++ A / A++
EER - COP (Cool - Heat) 4.22 - 4.43 3.36 - 3.93 3.11 - 3.71
Energy Label (Cool / Heat) A / A A / A B / A
AMBI
ENT
RAN
GE Cooling °C 46°C to -15°C
Heating °C 15°C to -20°
PHYS
ICAL
Indoor Unit Dimensions (H-W-D) mm 235 - 1586 - 690 235 - 1586 - 690 235 - 1586 - 690
Outdoor Unit Dimensions (H-W-D) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 35 - 95 35 - 95 35 - 95
AIRF
LOW
Indoor Unit Airflow Rate (l-m-h) l/s 283 - 375 - 517 333 - 425 - 567 350 - 458 - 567
Static Pressure (standard-upper) Pa n/a n/a n/a
Discharge Spigots n/a n/a n/a
SOU
ND Indoor Sound Pressure (l-m-h) dB(A) 32 - 38 - 44 35 - 41 - 46 36 - 42 - 46
Outdoor Sound Pressure (cool-heat) dB(A) 49 - 50 51 - 52 51 - 53
REFR
IGER
ANT
& P
IPEW
ORK
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 75 - 30 75 - 30 75 - 30
Pre-charged for m 30 30 30
Charge R410A (Factory - Additional) kg 3.1kg - 40g/m 3.1kg - 40g/m 3.1kg - 40g/m
Suitable for Replacement Tech. Yes Yes Yes
Indoor Drain Connection mm VP20 (20id 26od) VP20 (20id 26od) VP20 (20id 26od)
POW
ER
Power Supply (Outdoor) V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Interconnecting Cables 3 core + E 3 core + E 3 core + E
Running Current (Cool - Heat) A 3.72 per phase 5.42 per phase 6.66 per phase
Power Consumption (Cool - Heat) kW 2.53 - 2.37 3.56 - 3.72 4.31 - 4.50
Suggested Fuse Size - Max. Current A 20 - 16.1 per phase 20 - 15.9 per phase 20 - 16.1 per phase
Indoor Unit £849 £1,071 £1,090
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £2,184 £2,279 £2,426
Retail Price £3,099 £3,416 £3,582
Optional ControllerRBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 66
RAV
Com
mer
cial
RAV Split SystemsFloor Standing VRF Indoor Unit Conversions
It is now possible, utilising the RBC-CK1/CK2 interface, to convert floor standing VRF indoor units to connect to a standard RAV digital or super digital inverter outdoor unit. The interface fits to the indoor unit, with the unit shipped with interface fitted by AMP. It can then be connected to any of the standard RAV control options.
Floor Chassis
Indoor Unit AMP-MML-AP0154BH-E AMP-MML-AP0184BH-E AMP-MML-AP0244BH-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM564ATP-E RAV-SM564ATP-E RAV-SM804ATP-E
Nominal Cooling (Range) kW 5.0 5.0 6.7
Nominal Heating (Range) kW 5.3 5.3 7.7
Indoor Unit Dimensions (h-w-d) mm 600 - 1045 - 220 600 - 1045 - 220 600 - 1045 - 220
Outdoor Unit Dimensions (h-w-d) mm 550 - 780 - 290 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 29 - 40 29 - 40 29 - 44
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 1/2" - 1/4" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 30 - 30 30 - 30
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 16 16 20
Indoor Unit £1,075 £1,130 £1,166
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £840 £840 £1,177
Retail Price £1,981 £2,036 £2,409
Floor Cabinet
Indoor Unit AMP-MML-AP0154H-E AMP-MML-AP0184H-E AMP-MML-AP0244H-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM564ATP-E RAV-SM564ATP-E RAV-SM804ATP-E
Nominal Cooling (Range) kW 5.0 5.0 6.7
Nominal Heating (Range) kW 5.3 5.3 7.7
Indoor Unit Dimensions (H-W-D) mm 630 - 950 - 230 630 - 950 - 230 630 - 950 - 230
Outdoor Unit Dimensions (H-W-D) mm 550 - 780 - 290 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 37 - 44 40 - 44 40 - 44
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 1/2" - 1/4" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 30 - 30 30 - 30
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 16 16 20
Indoor Unit £1,243 £1,306 £1,352
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £840 £840 £1,177
Retail Price £2,149 £2,212 £2,595
Indoor unit cost includes RBC-CK1 and fitting ready for installation Units can also be used for twin split systems, contact AMP for details
Can be used on replacement technologyCan also be used with super digital outdoor units
Floor Chassis Floor Cabinet
ampair.co.uk | 01707 378 670 | [email protected] 67
RAV
Com
mer
cial
RAV Split SystemsFloor Standing VRF Indoor Unit Conversions
Indoor Unit AMP-MMF-AP0156H-E AMP-MMF-AP0246H-E AMP-MMF-AP0276H-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM564ATP-E RAV-SM804ATP-E RAV-SM804ATP-E
Nominal Cooling (Range) kW 5.0 6.7 6.7
Nominal Heating (Range) kW 5.3 7.7 7.7
Indoor Unit Dimensions (h-w-d) mm 1750 - 600 - 210 1750 - 600 - 210 1750 - 600 - 210
Outdoor Unit Dimensions (h-w-d) mm 550 - 780 - 290 550 - 780 - 290 550 - 780 - 290
Weight (Indoor - Outdoor) kg 46 - 40 47 - 44 47 - 44
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 30 - 30 30 - 30 30 - 30
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 16 20 20
Indoor Unit £1,539 £1,680 £1,723
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £840 £1,177 £1,177
Retail Price £2,445 £2,923 £2,966
Indoor Unit AMP-MMF-AP0366H-E AMP-MMF-AP0486H-E AMP-MMF-AP0566H-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM1104ATP-E RAV-SM1404ATP-E RAV-SM1603AT-E
Nominal Cooling (Range) kW 10.0 12.1 14.0
Nominal Heating (Range) kW 11.2 12.8 16.0
Indoor Unit Dimensions (h-w-d) mm 1750 - 600 -390 1750 - 600 -390 1750 - 600 -390
Outdoor Unit Dimensions (h-w-d) mm 890 - 900 - 320 890 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 62 - 68 62 - 68 62 - 99
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 50 - 30 50 - 30 50 - 30
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 25 25 32
Indoor Unit £1,767 £1,845 £1,925
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £1,549 £1,633 £2,059
Retail Price £3,382 £3,544 £4,050
Indoor unit cost includes RBC-CK1 and fitting ready for installation Units can also be used for twin split systems, contact AMP for details
Can be used on replacement technology
@amp_aircon | amp-air-conditioning 68
RAV
Com
mer
cial
RAV Split SystemsFloor Standing VRF Indoor Unit Conversions
Indoor Unit AMP-MMF-AP0156H-E AMP-MMF-AP0246H-E AMP-MMF-AP0276H-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP564ATP-E RAV-SP804ATP-E RAV-SP804ATP-E
Nominal Cooling (Range) kW 5.0 6.7 6.7
Nominal Heating (Range) kW 5.3 7.7 7.7
Indoor Unit Dimensions (h-w-d) mm 1750 - 600 - 210 1750 - 600 - 210 1750 - 600 - 210
Outdoor Unit Dimensions (h-w-d) mm 550 - 780 - 290 890 - 900 - 320 890 - 900 - 320
Weight (Indoor - Outdoor) kg 46 - 44 47 - 66 47 - 66
Pipe Sizes (Gas - Liquid) in 1/2" - 1/4" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 50 - 30 50 - 30 50 - 30
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 16 25 25
Indoor Unit £1,539 £1,680 £1,723
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £1,097 £1,628 £1,628
Retail Price £2,702 £3,374 £3,417
Indoor Unit AMP-MMF-AP0366H-E AMP-MMF-AP0486H-E AMP-MMF-AP0566H-E
Remote Controller inc. Time Clock RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT-E RAV-SP1404AT-E RAV-SP1604AT8-E
Nominal Cooling (Range) kW 10.0 12.1 14.0
Nominal Heating (Range) kW 11.2 12.8 16.0
Indoor Unit Dimensions (h-w-d) mm 1750 - 600 -390 1750 - 600 -390 1750 - 600 -390
Outdoor Unit Dimensions (h-w-d) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 62 - 93 62 - 93 62 - 95
Pipe Sizes (Gas - Liquid) in 5/8" - 3/8" 5/8" - 3/8" 5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.) m 75 - 30 75 - 30 75 - 30
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 400 - 3 - 50
Suggested Fuse Size A 25 25 20A per phase
Indoor Unit £1,767 £1,845 £1,925
Remote Controller inc. Time Clock £66 £66 £66
Outdoor Unit £1,995 £2,205 £2,426
Retail Price £3,828 £4,116 £4,417
Indoor unit cost includes RBC-CK1 and fitting ready for installation Units can also be used for twin split systems, contact AMP for details
Can be used on replacement technology
ampair.co.uk | 01707 378 670 | [email protected] 69
RAV
Com
mer
cial
“Very helpful and responsive when dealing with technical matters and on-site equipment issues. Always nice to know that back up is there when its needed most.”Glen Tempest - NCPI Solutions
Photo: Mickey Day, Warehouse Operative at AMP
@amp_aircon | amp-air-conditioning 70
RAV
Com
mer
cial
RAV Split SystemsDigital Inverter Twin Split Systems
OutdoorUnit
-Phase
-Range -
Refrigerant
Nom.Cool/Heat
-
Rmt. Control-
Branch Pipe
IndoorUnits
KRTP-EWall
Mounted
CTP-ECeiling
Suspended
MUT-ECompactCassette
UTP-E4 Way
Cassette
SDT-ESlim
Ducted
BTP-EStandardDucted
Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price
SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP
Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating
RAV-SM564ATP-E 5.0 / 5.3
2 x 30*
£1,490.00 £2,382.00 £1,840.00
Single Phase RBC-AMS41E 5.77 4.00 5.48 4.16 5.06 4.06
DI - R410A n/a A+ A A A+ B A+
RAV-SM804ATP-E 6.7 / 7.7
2 x 40*
£1,877.00 £2,451.00 £2,707.00 £2,257.00 £2,379.00
Single Phase RBC-AMS41E 5.62 4.01 5.62 4.01 5.81 4.05 5.58 4.07 5.04 3.83
DI - R410A n/a A+ A+ A+ A+ A+ A+ A A+ B A
RAV-SM1104ATP-E 10.0 / 11.2
2 x 56*
£2,397.00 £2,931.00 £3,067.00 £3,143.00 £2,651.00 £2,871.00
Single Phase RBC-AMS41E 5.13 4.18 5.70 4.27 5.04 4.17 5.72 4.28 5.09 4.16 5.00 4.14
DI - R410A n/a A A+ A+ A+ B A+ A+ A+ B A+ B A+
RAV-SM1404ATP-E 12.1 / 12.8
2 x 80*
£2,541.00 £3257.00 £3,423.00 £3,493.00
Single Phase RBC-AMS41E 5.27 4.19 5.53 4.55 5.25 4.19 5.53 4.42
DI - R410A n/a A A+ A A+ A A+ A A+
RAV-SM1603AT-E 14.0 / 16.0
2 x 80*
£2,967.00 £3,683.00 £3,849.00 £3,919.00
Single Phase RBC-AMS41E 4.94 4.36 4.94 4.36 5.47 4.47 4.78 3.86
DI - R410A n/a B A+ B A+ A A+ B A
RAV-SM2244AT8-E 20.0 / 22.4
2 x 110*
£4,764.00 £4,960.00 £5,128.00
Three Phase RBC-AMS41E 4.76 4.54 5.01 4.79 4.76 4.54
DI - R410A RBC-TWP101E B A+ B A++ B A+
RAV-SM2804AT8-E 23.0 / 27.0
2 x 140*
£5,303.00 £5,099.00 £5,447.00
Three Phase RBC-AMS41E 4.85 4.31 5.15 4.55 4.85 4.31
DI - R410A RBC-TWP101E B A+ A A+ B A+
ampair.co.uk | 01707 378 670 | [email protected] 71
RAV
Com
mer
cial
RAV Split SystemsDigital Inverter Twin Split Systems
Outdoor unitMaximum pipe run(Height difference)
Pipe Sizes Suggested Fuse Size
RAV-SM564ATP-E 30m - 30m 1/2" & 1/4" 16A
RAV-SM804ATP-E 30m - 30m 5/8" & 3/8" 20A
RAV-SM1104ATP-E 50m - 30m 5/8" & 3/8" 25A
RAV-SM1404ATP-E 50m - 30m 5/8" & 3/8" 25A
RAV-SM1603AT-E 50m - 30m 5/8" & 3/8" 32A
RAV-SM2244AT8-E 70m - 30m 1 1/8" & 1/2" 25A per phase
RAV-SM2804AT8-E 70m - 30m 1 1/8" & 1/2" 32A per phase
Outdoor Unit Details & Pipe Sizing
Indoor Unit Pipe Sizing
Indoor unit Pipe Sizes
30* 3/8" & 1/4"
40* 1/2" & 1/4"
56* 1/2" & 1/4"
80* 5/8" & 3/8"
110* 5/8" & 3/8"
140* 5/8" & 3/8"
Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values.
| System costs include all branch kits and spigot kits (where required) and 1 x RBC-AMS41E remote controller.
Optional ControllerRBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 72
RAV
Com
mer
cial
RAV Split SystemsSuper Digital Inverter Twin Split Systems
OutdoorUnit
-Phase
-Range -
Refrigerant
Nom.Cool/Heat
-
Rmt. Control-
Branch Pipe
IndoorUnits
KRTP-EWall
Mounted
CTP-ECeiling
Suspended
MUT-ECompactCassette
UTP-E4 Way
Cassette
SDT-ESlim
Ducted
BTP-EStandardDucted
Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price
SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP
Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating
RAV-SP564ATP-E 5.0 / 5.6
2 x 30*
£1,747.00 £2,639.00 £2,097.00
Single Phase RBC-AMS41E 5.82 4.01 5.61 4.20 5.10 3.90
SDI - R410A n/a A+ A+ A+ A+ A A
RAV-SP804ATP-E 7.1 / 8.0
2 x 40*
£2,328.00 £2,902.00 £3,158.00 £2,708.00 £2,830.00
Single Phase RBC-AMS41E 5.88 3.87 6.21 4.10 5.60 3.86 5.38 3.88 5.88 4.00
SDI - R410A n/a A+ A A++ A+ A+ A A A A+ A+
RAV-SP1104ATP-E 10.0 / 11.2
2 x 56*
£2,843.00 £3,377.00 £3,513.00 £3,589.00 £3,097.00 £3,317.00
Single Phase RBC-AMS41E 5.60 3.87 6.18 4.27 5.67 3.90 6.60 4.28 5.60 3.84 5.65 3.87
SDI - R410A n/a A+ A A++ A+ A+ A A++ A+ A+ A A+ A
RAV-SP1104AT8-E 10.0 / 11.2
2 x 56*
£3,032.00 £3,566.00 £3,702.00 £3,778.00 £3,286.00 £3,506.00
Three Phase RBC-AMS41E 5.51 3.87 6.35 4.41 5.64 3.90 6.57 4.28 5.55 3.84 5.65 3.87
SDI - R410A n/a A A A++ A+ A+ A A++ A+ A A A+ A
RAV-SP1404AT-E 12.3 / 14.0
2 x 80*
£3,113.00 £3,829.00 £3,995.00 £4,065.00
Single Phase RBC-AMS41E 4.95 4.00 5.14 4.09 6.18 4.61 5.22 4.03
SDI - R410A n/a B A A A+ A++ A++ A A+
RAV-SP1404AT8-E 12.3 / 14.0
2 x 80*
£3,187.00 £3,903.00 £4,069.00 £4,139.00
Three Phase RBC-AMS41E 4.95 4.00 5.49 4.65 5.87 4.86 5.09 4.48
SDI - R410A RBC-TWP101E B A A A++ A+ A++ B A+
RAV-SP1604AT8-E 14.0 / 16.0
2 x 80*
£3,334.00 £4,050.00 £4,216.00 £4,286.00
Three Phase RBC-AMS41E 4.55 3.64 5.49 4.73 5.49 4.73 4.97 4.35
SDI - R410A RBC-TWP101E C A A A++ A+ A++ B A+
ampair.co.uk | 01707 378 670 | [email protected] 73
RAV
Com
mer
cial
RAV Split SystemsSuper Digital Inverter Twin Split Systems
Outdoor Unit Details & Pipe Sizing
Indoor Unit Pipe Sizing
Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values. |
System costs include all branch kits and spigot kits (where required) and 1 x RBC-AMS41E remote controller.
Outdoor UnitMaximum pipe run(Height difference)
Pipe Sizes Suggested Fuse Size
RAV-SP564ATP-E 50m - 30m 1/2" & 1/4" 16A
RAV-SP804ATP-E 50m - 30m 5/8" & 3/8" 25A
RAV-SP1104ATP-E 75m - 30m 5/8" & 3/8" 25A
RAV-SP1104AT8-E 75m - 30m 5/8" & 3/8" 20A per phase
RAV-SP1404AT-E 75m - 30m 5/8" & 3/8" 25A
RAV-SP1404AT8-E 75m - 30m 5/8" & 3/8" 20A per phase
RAV-SP1604AT8-E 75m - 30m 5/8" & 3/8" 20A per phase
Indoor unit Pipe Sizes
30* 3/8" & 1/4"
40* 1/2" & 1/4"
56* 1/2" & 1/4"
80* 5/8" & 3/8"
Toshiba Rewards, the new loyalty scheme from Toshiba, see page 207 for details
@amp_aircon | amp-air-conditioning 74
RAV
Com
mer
cial
RAV Split SystemsDigital Inverter Triple Split Systems
OutdoorUnit
-Phase
-Range -
Refrigerant
Nom.Cool/Heat
-
Rmt. Control-
Branch Pipe
IndoorUnits
KRTP-EWall
Mounted
CTP-ECeiling
Suspended
MUT-ECompactCassette
UTP-E4 Way
Cassette
SDT-ESlim
Ducted
BTP-EStandardDucted
Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price
SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP
Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating
RAV-SM1104ATP-E 10.0 / 11.2
3 x 30*
£2,667.00 £4,025.00 £3,212.00
Single Phase RBC-AMS41E 5.70 4.27 5.04 4.17 5.09 4.16
DI - R410A RBC-TRP100E A+ A+ B A+ B A+
RAV-SM1404ATP-E 12.1 / 12.8
3 x 40*
£2,846.00 £3,707.00 £4,091.00 £3,416.00
Single Phase RBC-AMS41E 5.53 4.55 5.53 4.55 5.25 4.19 5.53 4.42
DI - R410A RBC-TRP100E A A+ A A+ A A+ A A+
RAV-SM1603AT-E 14.0 / 16.0
3 x 56*
£3,494.00 £4,295.00 £4,499.00 £4,613.00 £3,875.00 £4,205.00
Single Phase RBC-AMS41E 4.54 3.39 4.94 4.36 4.64 3.86 5.47 4.47 4.64 3.86 4.78 3.86
DI - R410A RBC-TRP100E C B B A+ B A A A+ B A B A
RAV-SM2244AT8-E 20.0 / 22.4
3 x 80*
£4,525.00 £5,599.00 £5,848.00 £5,953.00
Three Phase RBC-AMS41E 4.76 4.54 4.76 4.54 5.01 4.79 4.76 4.54
DI - R410A RBC-TRP100E B A+ B A+ B A++ B A+
RAV-SM2804AT8-E 23.0 / 27.0
3 x 80*
£4,620.00 £5,694.00 £5,943.00 £6,048.00
Three Phase RBC-AMS41E 4.85 4.31 4.85 4.31 5.15 4.55 4.85 4.31
DI - R410A RBC-TRP100E B A+ B A+ A A+ B A+
ampair.co.uk | 01707 378 670 | [email protected] 75
RAV
Com
mer
cial
RAV Split SystemsDigital Inverter Triple Split Systems
Outdoor Unit Details & Pipe Sizing
Indoor Unit Pipe Sizing
Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values. |
System costs include all branch kits and spigot kits (where required) and 1 x RBC-AMS41E remote controller.
Outdoor unitMaximum pipe run(Height difference)
Pipe Sizes Suggested Fuse Size
RAV-SM1104ATP-E 50m - 30m 5/8" & 3/8" 25A
RAV-SM1404ATP-E 50m - 30m 5/8" & 3/8" 25A
RAV-SM1603AT-E 50m - 30m 5/8" & 3/8" 32A
RAV-SM2244AT8-E 70m - 30m 1 1/8" & 1/2" 25A per phase
RAV-SM2804AT8-E 70m - 30m 1 1/8" & 1/2" 32A per phase
Indoor unit Pipe Sizes
30* 3/8" & 1/4"
40* 1/2" & 1/4"
56* 1/2" & 1/4"
80* 5/8" & 3/8"
@amp_aircon | amp-air-conditioning 76
RAV
Com
mer
cial
RAV Split SystemsSuper Digital Inverter Triple Split Systems
OutdoorUnit
-Phase
-Range -
Refrigerant
Nom.Cool/Heat
-
Rmt. Control-
Branch Pipe
IndoorUnits
KRTP-EWall
Mounted
CTP-ECeiling
Suspended
MUT-ECompactCassette
UTP-E4 Way
Cassette
SDT-ESlim
Ducted
BTP-EStandardDucted
Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price
SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP
Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating
RAV-SP1104ATP-E 10.0 / 11.2
3 x 30*
£3,133.00 £4,471.00 £3,652.00
Single Phase RBC-AMS41E 5.60 3.87 5.67 3.90 5.60 3.84
SDI - R410A RBC-TRP100E A+ A A+ A A+ A
RAV-SP1104AT8-E 10.0 / 11.2
3 x 30*
£3,322.00 £4,660.00 £3,847.00
Three Phase RBC-AMS41E 5.51 3.87 5.64 3.90 5.55 3.84
SDI - R410A RBC-TRP100E A A A+ A A A
RAV-SP1404AT-E 12.3 / 14.0
3 x 40*
£3,418.00 £4,279.00 £4,663.00 £3,988.00
Single Phase RBC-AMS41E 4.95 4.00 5.14 4.09 6.18 4.61 5.22 4.03
SDI - R410A RBC-TRP100E B A A A+ A++ A++ A A+
RAV-SP1404AT8-E 12.3 / 14.0
3 x 40*
£3,492.00 £4,353.00 £4,737.00 £4,062.00
Three Phase RBC-AMS41E 4.95 4.00 5.49 4.65 5.87 4.86 5.09 4.48
SDI - R410A RBC-TRP100E B A A A++ A+ A++ B A+
RAV-SP1604AT8-E 14.0 / 16.0
3 x 56*
£3861.00 £4,662.00 £4,866.00 £4,980.00 £4,242.00 £4,572.00
Three Phase RBC-AMS41E 4.55 3.64 5.49 4.73 4.95 4.65 5.49 4.73 4.95 4.43 4.97 4.35
SDI - R410A RBC-TRP100E C A A A++ B A+ A A++ B A+ B A+
ampair.co.uk | 01707 378 670 | [email protected] 77
RAV
Com
mer
cial
RAV Split SystemsSuper Digital Inverter Triple Split Systems
Outdoor Unit Details & Pipe Sizing
Indoor Unit Pipe Sizing
Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values. |
System costs include all branch kits and spigot kits (where required) and 1 x RBC-AMS41E remote controller.
Outdoor unitMaximum pipe run(Height difference)
Pipe Sizes Suggested Fuse Size
RAV-SP1104ATP-E 75m - 30m 5/8" & 3/8" 25A
RAV-SP1104AT8-E 75m - 30m 5/8" & 3/8" 20A per phase
RAV-SP1404AT-E 75m - 30m 5/8" & 3/8" 25A
RAV-SP1404AT8-E 75m - 30m 5/8" & 3/8" 20A per phase
RAV-SP1604AT8-E 75m - 30m 5/8" & 3/8" 20A per phase
Indoor unit Pipe Sizes
30* 3/8" & 1/4"
40* 1/2" & 1/4"
56* 1/2" & 1/4"
RAV
Com
mer
cial
78@amp_aircon | amp-air-conditioning
RAV Split SystemsDigital Inverter & Super Digital Inverter Quad Split Systems
OutdoorUnit
-Phase
-Range -
Refrigerant
Nom.Cool/Heat
-
Rmt. Control-
Branch Pipe
IndoorUnits
KRTP-EWall
Mounted
CTP-ECeiling
Suspended
MUT-ECompactCassette
UTP-E4 Way
Cassette
SDT-ESlim
Ducted
BTP-EStandardDucted
Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price
SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP
Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating
RAV-SM1404ATP-E 12.1 / 12.8
4 x 30*
£3,076.00 £4,860.00 £3,776.00
Single Phase RBC-AMS41E 5.53 4.55 5.25 4.19 5.53 4.42
DI - R410A RBC-DTWP101E A A+ A A+ A A+
RAV-SP1404AT-E 12.3 / 14.0
4 x 30*
£3,648.00 £5,432.00 £4,348.00
Single Phase RBC-AMS41E 4.95 4.00 6.18 4.61 5.22 4.03
SDI - R410A RBC-DTWP101E B A A++ A++ A A+
RAV-SP1404AT8-E 12.3 / 14.0
4 x 30*
£3,722.00 £5,506.00 £4,422.00
Three Phase RBC-AMS41E 4.95 4.00 5.87 4.86 5.09 4.48
SDI - R410A RBC-DTWP101E B A A+ A++ B A+
RAV-SM1603AT-E 14.0 / 16.0
4 x 40*
£3,602.00 £4,750.00 £5,262.00 £4,362.00 £4,606.00
Single Phase RBC-AMS41E 4.54 3.39 4.94 4.36 4.64 3.86 4.64 3.86 4.64 3.86
DI - R410A RBC-DTWP101E C B B A+ B A B A B A
RAV-SP1604AT8-E 14.0 / 16.0
4 x 40*
£3,969.00 £5,117.00 £5,629.00 £4,729.00 £4,973.00
Three Phase RBC-AMS41E 4.55 3.64 5.49 4.73 5.49 4.73 4.95 4.43 4.95 4.43
SDI - R410A RBC-DTWP101E C A A A++ A A++ B A+ B A+
RAV-SM2244AT8-E 20.0 / 22.4
4 x 56*
£4,836.00 £5,907.00 £6,179.00 £6,331.00 £5,347.00 £5,787.00
Three Phase RBC-AMS41E 4.76 4.54 4.76 4.54 4.76 4.54 5.01 4.79 4.76 4.54 4.76 4.54
DI - R410A RBC-DTWP101E B A+ B A+ B A+ B A++ B A+ B A+
RAV-SM2804AT8-E 23.0 / 27.0
4 x 80*
£5,054.00 £6,486.00 £6,818.00 £6,902.00
Three Phase RBC-AMS41E 4.85 4.31 4.85 4.31 5.15 4.55 4.85 4.31
DI - R410A RBC-DTWP101E B A+ B A+ A A+ B A+
ampair.co.uk | 01707 378 670 | [email protected] 79
RAV
Com
mer
cial
RAV Split SystemsDigital Inverter & Super Digital Inverter Quad Split Systems
Outdoor Unit Details & Pipe Sizing
Indoor Unit Pipe Sizing
Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values. |
System costs include all branch kits and spigot kits (where required) and 1 x RBC-AMS41E remote controller.
Outdoor unitMaximum pipe run(Height difference)
Pipe Sizes Suggested Fuse Size
RAV-SM1404ATP-E 50m - 30m 5/8" & 3/8" 25A
RAV-SP1404AT-E 75m - 30m 5/8" & 3/8" 25A
RAV-SP1404AT8-E 75m - 30m 5/8" & 3/8" 20A per phase
RAV-SM1603AT-E 50m - 30m 5/8" & 3/8" 32A
RAV-SP1604AT8-E 75m - 30m 5/8" & 3/8" 20A per phase
RAV-SM2244AT8-E 70m - 30m 1 1/8" & 1/2" 25A per phase
RAV-SM2804AT8-E 70m - 30m 1 1/8" & 1/2" 32A per phase
Indoor unit Pipe Sizes
30* 3/8" & 1/4"
40* 1/2" & 1/4"
56* 1/2" & 1/4"
80* 5/8" & 3/8"
Optional ControllerRBC-AMS54E-ES £105 Retail
RAV
Com
mer
cial
“AMP have been our preferred supplier for many years due to their outstanding product
knowledge, excellent service and friendly staff, they are our “go to” A/C Supplier”
Kevin Efford - Complete Cooling Systems limited
Photo: Tim Young, Commercial Manager at AMP
@amp_aircon | amp-air-conditioning 8080@amp_aircon | amp-air-conditioning
VRF Systems
VRF
Out
door
ampair.co.uk | 01707 378 670 | [email protected] 81ampair.co.uk | 01707 378 670 | [email protected] 81
@amp_aircon | amp-air-conditioning 82
VRF
Out
door
VRF OutdoorIntroduction
VRF technology offers the best solution for large commercial and industrial buildings, including hotels, hospitals, leisure and shopping centers.
The dual / triple inverter compressors guarantee high efficiency levels, operating flexibility and reduced maintenance requirements. Moreover, the wide range of indoor units make the Toshiba VRF system the most flexible choice to satisfy any kind of requirement and is ideal for many installations.
Quality has always been Toshiba’s strength and will remain the trademark that will differentiate Toshiba air conditioners from the competition. This is the philosophy behind every Toshiba product especially in the highly technological VRF systems where the use of the active oil management system and inverter controlled compressors, provide a significant reduction in mechanical and electrical stress, increasing the durability and reliability of the components.
With the sophisticated Toshiba technology and the use of 3 compressors and 3 inverters, the SMMSe systems ensure extraordinary flexibility in any application. The SMMSe offers innovations in energy savings with highly efficient DC twin rotary compressors and advanced vector-controlled inverters boasting higher COP at 50% partial load.
The new Toshiba three-pipe VRF Super Heat Recovery Multi System (SHRMi) delivers simultaneous cooling and heating to different zones or rooms and has exceptional energy efficiency.
The Toshiba MiNi-SMMS is a small VRF system which offers great flexibility and power, but with a small and compact chassis which bridges the gap between the versatile Multi-Split Systems and the larger capacity of the SMMSe.
Sophisticated inverter control permits matching of the actual refrigerant flow to the capacity required by each indoor unit in an application. This results in optimised efficiency of the refrigerant cycle and increased precision in maintaining the required temperature, improving comfort for the occupants.
ampair.co.uk | 01707 378 670 | [email protected] 83
VRF
Out
door
VRF OutdoorRange Overview
Page
Num
ber Nominal Cooling kW 12.1 14.0 15.5 22.4 28.0 33.5 40.0 45.0 50.4 56.0 61.5 68.0 73.0 78.5 85.0
Nominal Heating kW 12.5 16.0 18.0 25.0 31.5 37.5 45.0 50.0 56.5 63.0 69.0 76.5 81.5 88.0 95.0
Outdoor Unit Type 04** 05** 06** 08** 10** 12** 14** 16** 18** 20** 22** 24** 26** 28** 30**
Capacity Code (Hp) 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30
842 pipe Mini SMMS - heat pump
ü ü ü
85 2 pipe SMMSe - heat pump ü ü ü ü ü ü ü ü ü ü ü ü
n/aContact
AMP
2 pipe SMMSe - heat pump high efficiency
ü ü
95 3 pipe SHRMi - heat recovery ü ü ü ü ü ü ü ü ü ü ü ü
Page
Num
ber Nominal Cooling kW 90.0 96.0 101.0 106.0 112.0 118.0 123.5 130.0 135.0 140.4 146.0 151.5 157.0 162.5 168.0
Nominal Heating kW 100.0 108.0 113.0 119.5 127.0 132.0 138.0 145.0 150.0 156.0 163.0 164.0 176.0 177.0 178.0
Outdoor Unit Type 32** 34** 36** 38** 40** 42** 44** 46** 48** 50** 52** 54** 56** 58** 60**
Capacity Code (Hp) 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60
842 pipe Mini SMMS - heat pump
85 2 pipe SMMSe - heat pump ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü
n/aContact
AMP
2 pipe SMMSe - heat pump high efficiency
ü ü ü ü ü ü
95 3 pipe SHRMi - heat recovery ü ü ü ü ü ü
@amp_aircon | amp-air-conditioning 84
VRF
Out
door
VRF OutdoorMini SMMS Heat Pump Outdoor Units
Outdoor Unit MCY-MAP0401HT MCY-MAP0501HT MCY-MAP0601HT
Connection Kit n/a n/a n/a
PERF
ORM
ANCE
Horse Power 4 5 6
Nominal Cooling kW 12.1 14.0 15.5
Nominal Heating kW 12.5 16.0 18.0
Maximum Number of Indoor Units 6 8 9
Min - Max Connected Capacity Code** 3.2 - 5.2 4.0 - 6.5 4.3 - 7.8
EFFI
CIEN
CY
EER - COP 4.29 - 4.61 4.03 - 4.00 3.35 - 3.71
SEER - ESEER value (Office Profile) 7.09 - 7.39 6.45 - 6.73 5.51 - 5.76
SCOP - ESCOP (Value) 5.86 - 6.09 5.07 - 5.26 5.14 - 5.37
PHYS
ICAL
Number of Modules 1 1 1
Size of Modules HP 4HP 5HP 6HP
Height mm 1340 1340 1340
Width mm 900 900 900
Depth mm 320 320 320
Weight kg 117 117 117
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 49.0 - 50.0 50.0 - 52.0 51.0 - 53.0
Airflow Rate l/s 1616 1700 1783
Max External Static Pressure** Pa 0 0 0
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8" 5/8" 3/4"
Liquid Pipe Size in 3/8" 3/8" 3/8"
Discharge Pipe Size in n/a n/a n/a
R410A Refrigerant Base Charge kg 7.2 7.2 7.2
POW
ER
Power Supply V-Ph-Hz 230- 1 -50 230- 1 -50 230- 1 -50
Suggested Fuse Size A 20 25 32
Power Input (Cool - Heat) kW 2.82 - 2.71 3.47 - 4.00 4.63 - 4.85
Running Current (Cool - Heat) A 13.2 - 12.5 16.1 - 18.3 21.4 - 22.2
Starting Current A Soft Start Soft Start Soft Start
Retail Price £3,575 £4,064 £4,369
For pipe work limitations see installation manual | 2 core non polar 1.5mm2 screened cable | **Condition apply, see technical manual for details
ampair.co.uk | 01707 378 670 | [email protected] 85
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-MAP0806HT8P-E MMY-MAP1006HT8P-E MMY-MAP1206HT8P-E
Connection Kit n/a n/a n/a
PERF
ORM
ANCE
Horse Power 8 10 12
Nominal Cooling kW 22.4 28.0 33.5
Nominal Heating kW 25.0 31.5 37.5
Maximum Number of Indoor Units 18 22 27
Min - Max Connected Capacity Code** 4.00 - 10.8 5.0 - 13.5 6.0 - 16.2
EFFI
CIEN
CY
EER - COP 4.04 - 4.52 3.64 - 4.25 3.35 - 3.89
SEER - ESEER value (Office Profile) 7.18 - 7.55 7.04 - 7.45 7.23 - 7.72
SCOP - ESCOP (Value) 5.71 - 5.95 5.45 - 5.69 5.05 - 5.29
PHYS
ICAL
Number of Modules 1 1 1
Size of Modules HP 8HP 10HP 12HP
Height mm 1830 1830 1830
Width* mm 990 990 990
Depth mm 780 780 780
Weight kg 242 242 242
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 55.0 - 56.0 57.0 - 58.0 59.0 - 61.0
Airflow Rate l/s 2694 2694 3389
Max External Static Pressure** Pa 60 60 50
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/4" 7/8" 1 1/8"
Liquid Pipe Size in 1/2" 1/2" 1/2"
Discharge Pipe Size in na na na
R410A Refrigerant Base Charge kg 11.5 11.5 11.5
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC TBC
Power Input (Cool - Heat) kW 5.54 - 5.53 7.69 - 7.41 10.0 - 9.65
Running Current (Cool - Heat) A 8.79 - 8.77 12.1 - 11.6 15.5 - 15.0
Starting Current A soft start soft start soft start
Retail Price £6,003 £6,574 £7,302*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
@amp_aircon | amp-air-conditioning 86
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-MAP1406HT8P-E MMY-MAP1606HT8P-E MMY-MAP1806HT8P-E
Connection Kit n/a n/a n/a
PERF
ORM
ANCE
Horse Power 14 16 18
Nominal Cooling kW 40.0 45.0 50.4
Nominal Heating kW 45.0 50.0 56.5
Maximum Number of Indoor Units 31 36 40
Min - Max Connected Capacity Code** 7.0 - 19.9 8.0 - 21.6 9.0 - 24.3
EFFI
CIEN
CY
EER - COP 3.25 - 4.02 3.15 - 3.88 3.45 - 3.97
SEER - ESEER value (Office Profile) 6.96 - 7.42 7.09 - 7.59 6.83 - 7.25
SCOP - ESCOP (Value) 5.08 - 5.29 4.86 - 5.07 4.99 - 5.20
PHYS
ICAL
Number of Modules 1 1 1
Size of Modules HP 14HP 16HP 18HP
Height mm 1830 1830 1830
Width* mm 1210 1210 1600
Depth mm 780 780 780
Weight kg 300 300 371
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 60.0 - 62.0 62.0 - 64.0 60.0 - 61.0
Airflow Rate l/s 3389 3500 4805
Max External Static Pressure** Pa 50 40 50
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 1/8" 1 1/8" 1 1/8"
Liquid Pipe Size in 5/8" 5/8" 5/8"
Discharge Pipe Size in na na na
R410A Refrigerant Base Charge kg 11.5 11.5 11.5
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC TBC
Power Input (Cool - Heat) kW 12.3 - 11.2 14.3 - 12.9 14.6 - 14.1
Running Current (Cool - Heat) A 19.5 - 17.8 22.4 - 20.2 22.9 - 22.1
Starting Current A Soft Start Soft Start Soft Start
Retail Price £9,132 £9,509 £10,460*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
SMMSe Hi COP combinations
also available. Contact AMP
for moreinformation.
ampair.co.uk | 01707 378 670 | [email protected] 87
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-MAP2006HT8P-E MMY-AP2206HT8P-E
Connection Kit n/a n/a
PERF
ORM
ANCE
Horse Power 20 22
Nominal Cooling kW 56.0 61.5
Nominal Heating kW 63.0 64.0
Maximum Number of Indoor Units 45 49
Min - Max Connected Capacity Code** 10.0 - 27.0 11.0 - 29.7
EFFI
CIEN
CY
EER - COP 3.24 - 3.71 2.65 - 3.74
SEER - ESEER value (Office Profile) 6.73 - 7.17 6.61 - 7.11
SCOP - ESCOP (Value) 4.73 - 4.95 4.76 - 4.98
PHYS
ICAL
Number of Modules 1 1
Size of Modules HP 20HP 22HP
Height mm 1830 1830
Width* mm 1600 1600
Depth mm 780 780
Weight kg 371 371
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 61.0 - 62.0 61.0 - 62.0
Airflow Rate l/s 4972 5139
Max External Static Pressure** Pa 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 1/8" 1 1/8"
Liquid Pipe Size in 5/8" 3/4"
Discharge Pipe Size in na na
R410A Refrigerant Base Charge kg 11.5 11.5
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC
Power Input (Cool - Heat) kW 17.3 - 17.0 23.2 - 17.1
Running Current (Cool - Heat) A 26.8 - 26.1 35.6 - 26.5
Starting Current A Soft Start Soft Start
Retail Price £11,192 £11,975*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
@amp_aircon | amp-air-conditioning 88
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-AP2416HT8P-E MMY-AP2616HT8P-E MMY-AP2816HT8P-E
Connection Kit RBM-BT14E RBM-BT24E RBM-BT24E
PERF
ORM
ANCE
Horse Power 24 26 28
Nominal Cooling kW 67.0 73.5 78.5
Nominal Heating kW 75.0 82.5 87.5
Maximum Number of Indoor Units 54 58 63
Min - Max Connected Capacity Code** 12.0 - 32.4 13.0 - 35.1 14.0 - 37.8
EFFI
CIEN
CY
EER - COP 3.35 - 3.89 3.30 - 3.96 3.23 - 3.88
SEER - ESEER value (Office Profile) 7.22 - 7.71 7.09 - 7.56 7.14 - 7.63
SCOP - ESCOP (Value) 5.08 - 5.31 5.07 - 5.29 4.96 - 5.18
PHYS
ICAL
Number of Modules 2 2 2
Size of Modules HP 12HP+12HP 14HP+12HP 16HP+12HP
Height mm 1830 1830 1830
Width* mm 2000 2220 2220
Depth mm 780 780 780
Weight kg 484 542 542
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 62.0 - 64.0 62.5 - 64.5 64.0 - 66.0
Airflow Rate l/s 6778 6778 6889
Max External Static Pressure** Pa 50 50 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 3/8" 1 3/8" 1 3/8"
Liquid Pipe Size in 3/4" 3/4" 3/4"
Discharge Pipe Size in na na na
R410A Refrigerant Base Charge kg 23 23 23
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC TBC
Power Input (Cool - Heat) kW 20.0 - 19.3 22.3 - 20.9 24.3 - 22.6
Running Current (Cool - Heat) A 31.0 - 30.0 35.0 - 32.8 37.9 - 35.2
Starting Current A Soft Start Soft Start Soft Start
Outdoor Unit £14,604 £16,434 £16,811
Connection Kit £127 £158 £158
Retail Price £14,731 £16,592 £16,969*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
SMMSe Hi COP combinations
also available. Contact AMP
for moreinformation.
ampair.co.uk | 01707 378 670 | [email protected] 89
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-AP3016HT8P-E MMY-AP3216HT8P-E MMY-AP3416HT8P-E
Connection Kit RBM-BT24E RBM-BT24E RBM-BT24E
PERF
ORM
ANCE
Horse Power 30 32 34
Nominal Cooling kW 85.0 90.0 95.4
Nominal Heating kW 95.0 100.0 106.0
Maximum Number of Indoor Units 64 64 64
Min - Max Connected Capacity Code** 15.0 - 40.5 16.0 - 43.2 17.0 - 45.9
EFFI
CIEN
CY
EER - COP 3.20 - 3.94 3.15 - 3.88 3.30 - 3.93
SEER - ESEER value (Office Profile) 7.02 - 7.50 7.08 - 7.57 6.96 - 7.41
SCOP - ESCOP (Value) 4.96 - 5.17 4.86 - 5.07 4.93 - 5.14
PHYS
ICAL
Number of Modules 2 2 2
Size of Modules HP 16HP+14HP 16HP+16HP 18HP+16HP
Height mm 1830 1830 1830
Width* mm 2440 2440 2830
Depth mm 780 780 780
Weight kg 600 600 671
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 64.5 - 66.5 65.0 - 67.0 64.5 - 66.0
Airflow Rate l/s 6889 7000 8305
Max External Static Pressure** Pa 40 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 3/8" 1 3/8" 1 3/8"
Liquid Pipe Size in 3/4" 3/4" 3/4"
Discharge Pipe Size in na na na
R410A Refrigerant Base Charge kg 23 23 23
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC TBC
Power Input (Cool - Heat) kW 26.6 - 24.1 28.6 - 25.8 28.9 - 27.0
Running Current (Cool - Heat) A 41.9 - 38.0 44.8 - 40.4 45.3 - 42.3
Starting Current A Soft Start Soft Start Soft Start
Outdoor Unit £18,641 £19,018 £19,969
Connection Kit £158 £158 £158
Retail Price £18,799 £19,176 £20,127*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
@amp_aircon | amp-air-conditioning 90
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-AP3616HT8P-E MMY-AP3816HT8P-E MMY-AP4016HT8P-E
Connection Kit RBM-BT24E RBM-BT24E RBM-BT24E
PERF
ORM
ANCE
Horse Power 36 38 40
Nominal Cooling kW 101.0 106.5 112.0
Nominal Heating kW 113.0 114.0 126.0
Maximum Number of Indoor Units 64 64 64
Min - Max Connected Capacity Code** 18.0 - 48.6 19.0 - 51.3 20.0 - 54.0
EFFI
CIEN
CY
EER - COP 3.20 - 3.78 2.84 - 3.80 3.24 - 3.71
SEER - ESEER value (Office Profile) 6.90 - 7.36 6.83 - 7.33 6.74 - 7.17
SCOP - ESCOP (Value) 4.79 - 5.00 4.80 - 5.01 4.73 - 4.95
PHYS
ICAL
Number of Modules 2 2 2
Size of Modules HP 20HP+16HP 22HP+16HP 20HP+20HP
Height mm 1830 1830 1830
Width* mm 2830 2830 3220
Depth mm 780 780 780
Weight kg 671 671 742
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 64.5 - 66.5 64.5 - 66.5 64.0 - 65.0
Airflow Rate l/s 8472 8639 9944
Max External Static Pressure** Pa 40 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 5/8" 1 5/8" 1 5/8"
Liquid Pipe Size in 7/8" 7/8" 7/8"
Discharge Pipe Size in n/a n/a n/a
R410A Refrigerant Base Charge kg 23 23 23
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC TBC
Power Input (Cool - Heat) kW 31.6 - 29.9 37.5 - 30.0 34.6 - 34.0
Running Current (Cool - Heat) A 49.2 - 46.3 58.0 - 46.7 53.6 - 52.2
Starting Current A Soft Start Soft Start Soft Start
Outdoor Unit £20,701 £21,484 £22,384
Connection Kit £158 £158 £158
Retail Price £20,859 £21,642 £22,542*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
SMMSe Hi COP combinations
also available. Contact AMP
for moreinformation.
ampair.co.uk | 01707 378 670 | [email protected] 91
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-AP4216HT8P-E MMY-AP4416HT8P-E
Connection Kit RBM-BT24E RBM-BT24E
PERF
ORM
ANCE
Horse Power 42 44
Nominal Cooling kW 117.5 123.5
Nominal Heating kW 127.0 128.0
Maximum Number of Indoor Units 64 64
Min - Max Connected Capacity Code** 21.0 - 56.7 22.0 - 59.4
EFFI
CIEN
CY
EER - COP 2.90 - 3.72 2.65 - 3.74
SEER - ESEER value (Office Profile) 6.67 - 7.14 6.60 - 7.10
SCOP - ESCOP (Value) 4.74 - 4.96 4.77 - 4.98
PHYS
ICAL
Number of Modules 2 2
Size of Modules HP 22HP+20HP 22HP+22HP
Height mm 1830 1830
Width* mm 3220 3220
Depth mm 780 780
Weight kg 742 742
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 64.0 - 65.0 64.0 - 65.0
Airflow Rate l/s 10111 10278
Max External Static Pressure** Pa 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 5/8" 1 5/8"
Liquid Pipe Size in 7/8" 7/8"
Discharge Pipe Size in n/a n/a
R410A Refrigerant Base Charge kg 23 23
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC
Power Input (Cool - Heat) kW 40.5 - 34.1 46.4 - 34.2
Running Current (Cool - Heat) A 62.4 - 52.6 71.2 - 53.0
Starting Current A Soft Start Soft Start
Outdoor Unit £23,167 £23,950
Connection Kit £158 £158
Retail Price £23,325 £24,108*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
@amp_aircon | amp-air-conditioning 92
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-AP4616HT8P-E MMY-AP4816HT8P-E MMY-AP5016HT8P-E
Connection Kit RBM-BT24E x 2 RBM-BT24E x 2 RBM-BT24E x 2
PERF
ORM
ANCE
Horse Power 46 48 50
Nominal Cooling kW 130.0 135.0 140.4
Nominal Heating kW 145.0 150.0 156.0
Maximum Number of Indoor Units 64 64 64
Min - Max Connected Capacity Code** 23.0 - 62.1 24.0 - 64.8 25.0 - 67.5
EFFI
CIEN
CY
EER - COP 3.18 - 3.92 3.15 - 3.88 3.25 - 3.91
SEER - ESEER value (Office Profile) 7.04 - 7.53 7.09 - 7.58 7.00 - 7.46
SCOP - ESCOP (Value) 4.93 - 5.14 4.86 - 5.07 4.90 - 5.11
PHYS
ICAL
Number of Modules 3 3 3
Size of Modules HP 16HP+16HP+14HP 16HP+16HP+16HP 18HP+16HP+16HP
Height mm 1830 1830 1830
Width* mm 3670 3670 4060
Depth mm 780 780 780
Weight kg 900 900 971
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 66.5 - 68.5 67.0 - 69.0 66.5 - 68.0
Airflow Rate l/s 10389 10500 11806
Max External Static Pressure** Pa 40 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 5/8" 1 5/8" 1 5/8"
Liquid Pipe Size in 7/8" 7/8" 7/8"
Discharge Pipe Size in n/a n/a n/a
R410A Refrigerant Base Charge kg 34.5 34.5 34.5
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC TBC
Power Input (Cool - Heat) kW 40.9 - 37.0 42.9 - 38.7 43.2 - 39.9
Running Current (Cool - Heat) A 64.3 - 58.2 67.2 - 60.6 67.7 - 62.5
Starting Current A Soft Start Soft Start Soft Start
Outdoor Unit £28,150 £28,527 £29,478
Connection Kit £316 £316 £316
Retail Price £28,466 £28,843 £29,794*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
SMMSe Hi COP combinations
also available. Contact AMP
for moreinformation.
ampair.co.uk | 01707 378 670 | [email protected] 93
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-AP5216HT8P-E MMY-AP5416HT8P-E MMY-AP5616HT8P-E
Connection Kit RBM-BT24E x 2 RBM-BT24E x 2 RBM-BT24E x 2
PERF
ORM
ANCE
Horse Power 52 54 56
Nominal Cooling kW 146.0 151.5 157.0
Nominal Heating kW 163.0 164.0 176.0
Maximum Number of Indoor Units 64 64 64
Min - Max Connected Capacity Code** 26.0 - 70.2 27.0 - 72.9 28.0 - 75.6
EFFI
CIEN
CY
EER - COP 3.18 - 3.81 2.92 - 3.82 3.21 - 3.75
SEER - ESEER value (Office Profile) 6.96 - 7.43 6.91 - 7.41 6.84 - 7.30
SCOP - ESCOP (Value) 4.81 - 5.02 4.81 - 5.02 476 - 4.98
PHYS
ICAL
Number of Modules 3 3 3
Size of Modules HP 20HP+16HP+16HP 22HP+16HP+16HP 20HP+20HP+16HP
Height mm 1830 1830 1830
Width* mm 4060 4060 4450
Depth mm 780 780 780
Weight kg 971 971 1042
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 66.5 - 68.5 66.5 - 68.5 66.5 - 67.5
Airflow Rate l/s 11972 12139 13444
Max External Static Pressure** Pa 40 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 5/8" 1 5/8" 1 5/8"
Liquid Pipe Size in 7/8" 7/8" 7/8"
Discharge Pipe Size in n/a n/a n/a
R410A Refrigerant Base Charge kg 34.5 34.5 34.5
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC TBC
Power Input (Cool - Heat) kW 45.9 - 42.8 51.8 - 42.9 48.9 - 46.9
Running Current (Cool - Heat) A 71.6 - 66.5 80.4 - 66.9 76.0 - 72.4
Starting Current A Soft Start Soft Start Soft Start
Outdoor Unit £30,210 £30,993 £31,893
Connection Kit £316 £316 £316
Retail Price £30,526 £31,309 £32,209*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
@amp_aircon | amp-air-conditioning 94
VRF
Out
door
VRF OutdoorSMMSe Heat Pump Outdoor Units
Outdoor Unit MMY-AP5816HT8P-E MMY-AP6016HT8P-E
Connection Kit RBM-BT24E x 2 RBM-BT24E x 2
PERF
ORM
ANCE
Horse Power 58 60
Nominal Cooling kW 162.5 168.0
Nominal Heating kW 177.0 178.0
Maximum Number of Indoor Units 64 64
Min - Max Connected Capacity Code** 29.0 - 78.3 30.0 - 81.0
EFFI
CIEN
CY
EER - COP 2.97 - 3.77 2.77 - 3.78
SEER - ESEER value (Office Profile) 6.76 - 7.26 6.80 - 7.28
SCOP - ESCOP (Value) 4.78 - 5.00 4.77 - 4.98
PHYS
ICAL
Number of Modules 3 3
Size of Modules HP 22HP+20HP+16HP 22HP+22HP+16HP
Height mm 1830 1830
Width* mm 4450 4450
Depth mm 780 780
Weight kg 1042 1042
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 66.5 - 67.5 66.5 - 67.5
Airflow Rate l/s 13611 13778
Max External Static Pressure** Pa 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 5/8" 1 5/8"
Liquid Pipe Size in 7/8" 7/8"
Discharge Pipe Size in na na
R410A Refrigerant Base Charge kg 34.5 34.5
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A TBC TBC
Power Input (Cool - Heat) kW 54.8 - 47.0 60.7 - 47.1
Running Current (Cool - Heat) A 84.8 - 72.8 93.6 - 73.2
Starting Current A Soft Start Soft Start
Outdoor Unit £32,676 £33,459
Connection Kit £316 £316
Retail Price £32,992 £33,775*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
SMMSe Hi COP combinations
also available. Contact AMP
for moreinformation.
ampair.co.uk | 01707 378 670 | [email protected] 95
VRF
Out
door
VRF OutdoorSHRMi Heat Recovery Outdoor Units
Outdoor Unit MMY-MAP0804FT8-E MMY-MAP1004FT8-E MMY-MAP1204FT8-E
Connection Kit n/a n/a n/a
PERF
ORM
ANCE
Horse Power 8 10 12
Nominal Cooling kW 22.4 28.0 33.5
Nominal Heating kW 25.0 31.5 37.5
Maximum Number of Indoor Units 13 16 20
Min - Max Connected Capacity Code** 5.6 - 10.8 7.0 - 13.5 8.4 - 16.2
EFFI
CIEN
CY
EER - COP 4.33 - 4.40 3.85 - 4.20 4.00 - 4.14
SEER - ESEER value (Office Profile) 7.13 - 7.45 6.78 - 7.13 7.04 - 7.41
SCOP - ESCOP (Value) 5.18 - 5.35 5.16 - 5.35 5.11 - 5.30
PHYS
ICAL
Number of Modules 1 1 1
Size of Modules HP 8HP 10HP 12HP
Height mm 1830 1830 1830
Width* mm 990 990 1210
Depth mm 780 780 780
Weight kg 259 259 334
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 55.0 - 57.0 57.0 - 59.0 60.0 - 62.0
Airflow Rate l/s 2417 2611 3333
Max External Static Pressure** Pa 50 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 7/8" 7/8" 1 1/8"
Liquid Pipe Size in 1/2" 1/2" 1/2"
Discharge Pipe Size in 3/4" 3/4" 3/4"
R410A Refrigerant Base Charge kg 11 11 11
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A 16 20 25
Power Input (Cool - Heat) kW 5.17 - 5.68 7.28 - 7.50 8.38 - 9.05
Running Current (Cool - Heat) A 8.3 - 9.1 11.4 - 12.0 13.4 - 14.5
Starting Current A soft start soft start soft start
Retail Price £6,265 £6,816 £9,384*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
@amp_aircon | amp-air-conditioning 96
VRF
Out
door
Outdoor Unit MMY-MAP1404FT8-E MMY-AP1614FT8-E MMY-AP1814FT8-E
Connection Kit n/a RBM-BT14FE RBM-BT14FE
PERF
ORM
ANCE
Horse Power 14 16 18
Nominal Cooling kW 40.0 45.0 50.4
Nominal Heating kW 45.0 50.0 56.5
Maximum Number of Indoor Units 23 27 30
Min - Max Connected Capacity Code** 9.8 - 18.9 11.2 - 21.6 12.6 - 24.3
EFFI
CIEN
CY
EER - COP 3.54 - 3.54 4.32 - 4.40 4.05 - 4.29
SEER - ESEER value (Office Profile) 6.35 - 6.68 7.09 - 7.42 6.88 - 7.22
SCOP - ESCOP (Value) 4.85 - 5.08 5.18 - 5.36 5.15 - 5.34
PHYS
ICAL
Number of Modules 1 2 2
Size of Modules HP 14HP 8HP + 8HP 10HP + 8HP
Height mm 1830 1830 1830
Width* mm 1210 2000 2000
Depth mm 780 780 780
Weight kg 334 518 518
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 62.0 - 64.0 58.0 - 60.0 59.5 - 61.5
Airflow Rate l/s 3611 4834 5028
Max External Static Pressure** Pa 40 50 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 1/8" 1 1/8" 1 1/8"
Liquid Pipe Size in 5/8" 3/4" 3/4"
Discharge Pipe Size in 7/8" 7/8" 7/8"
R410A Refrigerant Base Charge kg 11 22 22
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A 25 16 & 16 20 & 16
Power Input (Cool - Heat) kW 11.30 - 12.70 10.42 - 11.36 12.45 - 13.18
Running Current (Cool - Heat) A 17.8 - 19.9 16.7 - 18.2 19.7 - 21.1
Starting Current A Soft Start Soft Start Soft Start
Outdoor Unit £9,853 £12,530 £13,081
Connection Kit n/a £128 £128
Retail Price £9,853 £12,658 £13,209*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
VRF OutdoorSHRMi Heat Recovery Outdoor Units
ampair.co.uk | 01707 378 670 | [email protected] 97
VRF
Out
door
Outdoor Unit MMY-AP2014FT8-E MMY-AP2214FT8-E MMY-AP2414FT8-E
Connection Kit RBM-BT14FE RBM-BT14FE RBM-BT14FE
PERF
ORM
ANCE
Horse Power 20 22 24
Nominal Cooling kW 56.0 61.5 68.0
Nominal Heating kW 63.0 69.0 76.5
Maximum Number of Indoor Units 33 37 40
Min - Max Connected Capacity Code** 14.0 - 27.0 15.4 - 29.7 16.8 - 32.4
EFFI
CIEN
CY
EER - COP 3.85 - 4.20 3.93 - 4.17 3.66 - 3.79
SEER - ESEER value (Office Profile) 6.78 - 7.13 6.92 - 7.28 6.27 - 6.58
SCOP - ESCOP (Value) 5.14 - 5.34 5.13 - 5.32 4.80 - 5.00
PHYS
ICAL
Number of Modules 2 2 2
Size of Modules HP 10HP + 10HP 12HP + 10HP 14HP + 10HP
Height mm 1830 1830 1830
Width* mm 2000 2220 2220
Depth mm 780 780 780
Weight kg 518 593 593
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 60.0 - 62.0 62.0 - 64.0 63.5 - 65.5
Airflow Rate l/s 5222 5944 6222
Max External Static Pressure** Pa 40 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 1/8" 1 3/8" 1 3/8"
Liquid Pipe Size in 3/4" 3/4" 3/4"
Discharge Pipe Size in 7/8" 1 1/8" 1 1/8"
R410A Refrigerant Base Charge kg 22 22 22
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A 20 & 20 20 & 20 25 & 20
Power Input (Cool - Heat) kW 14.56 - 15.00 15.66 - 16.55 18.58 - 20.20
Running Current (Cool - Heat) A 22.8 - 24.0 24.8 - 26.5 29.1 - 31.9
Starting Current A Soft Start Soft Start Soft Start
Outdoor Unit £13,632 £16,200 £16,669
Connection Kit £128 £128 £128
Retail Price £13,760 £16,328 £16,797*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
VRF OutdoorSHRMi Heat Recovery Outdoor Units
@amp_aircon | amp-air-conditioning 98
VRF
Out
door
Outdoor Unit MMY-AP2614FT8-E MMY-AP2814FT8-E MMY-AP3014FT8-E
Connection Kit RBM-BT24FE RBM-BT24FE RBM-BT24FE x 2
PERF
ORM
ANCE
Horse Power 26 28 30
Nominal Cooling kW 73.0 78.5 85.0
Nominal Heating kW 81.5 88.0 95.0
Maximum Number of Indoor Units 43 47 48
Min - Max Connected Capacity Code** 18.2 - 35.1 19.6 - 37.8 21.0 - 40.5
EFFI
CIEN
CY
EER - COP 3.75 - 3.82 3.57 - 3.58 3.82 - 4.19
SEER - ESEER value (Office Profile) 66.6 - 7.01 6.40 - 6.74 6.73 - 7.08
SCOP - ESCOP (Value) 4.92 - 5.13 4.90 - 5.13 5.13 - 5.32
PHYS
ICAL
Number of Modules 2 2 3
Size of Modules HP 14HP + 12HP 14HP + 14HP 10HP + 10HP + 10HP
Height mm 1830 1830 1830
Width* mm 2440 2440 3010
Depth mm 780 780 780
Weight kg 668 668 777
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 64.5 - 66.5 65.0 - 67.0 62.0 - 64.0
Airflow Rate l/s 6944 7222 7833
Max External Static Pressure** Pa 40 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 3/8" 1 3/8" 1 3/8"
Liquid Pipe Size in 7/8" 7/8" 7/8"
Discharge Pipe Size in 1 1/8" 1 1/8" 1 1/8"
R410A Refrigerant Base Charge kg 22 22 33
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A 25 & 20 25 & 25 20, 20 & 20
Power Input (Cool - Heat) kW 19.48 - 21.35 21.98 - 24.60 22.26 - 22.70
Running Current (Cool - Heat) A 30.9 - 33.8 34.5 - 38.6 34.9 - 36.4
Starting Current A Soft Start Soft Start Soft Start
Outdoor Unit £19,237 £19,706 £20,448
Connection Kit £159 £159 £318
Retail Price £19,396 £19,865 £20,766*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-10°C to 43°C | heating operating range -20°C to 15.5°C| 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
VRF OutdoorSHRMi Heat Recovery Outdoor Units
ampair.co.uk | 01707 378 670 | [email protected] 99
VRF
Out
door
Outdoor Unit MMY-AP3214FT8-E MMY-AP3414FT8-E
Connection Kit RBM-BT24FE x 2 RBM-BT24FE x 2
PERF
ORM
ANCE
Horse Power 32 34
Nominal Cooling kW 90.0 96.0
Nominal Heating kW 100.0 108.0
Maximum Number of Indoor Units 48 48
Min - Max Connected Capacity Code** 22.4 - 43.2 23.8 - 45.9
EFFI
CIEN
CY
EER - COP 3.89 - 4.19 3.71 - 3.90
SEER - ESEER value (Office Profile) 6.85 - 7.21 6.57 - 6.92
SCOP - ESCOP (Value) 5.16 - 5.35 4.95 - 5.15
PHYS
ICAL
Number of Modules 3 3
Size of Modules HP 12HP + 10HP + 10HP 14HP + 10HP + 10HP
Height mm 1830 1830
Width* mm 3230 3230
Depth mm 780 780
Weight kg 852 852
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 63.0 - 65.0 64.5 - 65.0
Airflow Rate l/s 8555 8833
Max External Static Pressure** Pa 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 3/8" 1 3/8"
Liquid Pipe Size in 7/8" 7/8"
Discharge Pipe Size in 1 1/8" 1 1/8"
R410A Refrigerant Base Charge kg 33 33
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A 20, 20 & 20 25, 20 & 20
Power Input (Cool - Heat) kW 23.15 - 23.85 25.86 - 27.70
Running Current (Cool - Heat) A 36.6 - 38.2 40.6 - 44.0
Starting Current A Soft Start Soft Start
Outdoor Unit £23,016 £23,485
Connection Kit £318 £318
Retail Price £23,334 £23,803*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
VRF OutdoorSHRMi Heat Recovery Outdoor Units
@amp_aircon | amp-air-conditioning 100
VRF
Out
door
Outdoor Unit MMY-AP3614FT8-E MMY-AP3814FT8-E
Connection Kit RBM-BT24FE x 2 RBM-BT24FE x 2
PERF
ORM
ANCE
Horse Power 36 38
Nominal Cooling kW 101.0 106.5
Nominal Heating kW 113.0 119.5
Maximum Number of Indoor Units 48 48
Min - Max Connected Capacity Code** 25.2 - 48.3 26.6 - 51.3
EFFI
CIEN
CY
EER - COP 3.98 - 4.13 3.82 - 3.91
SEER - ESEER value (Office Profile) 6.69 - 7.04 6.48 - 6.82
SCOP - ESCOP (Value) 4.98 - 5.18 4.90 - 5.11
PHYS
ICAL
Number of Modules 3 3
Size of Modules HP 12HP + 12HP + 12HP 14HP + 12HP + 12HP
Height mm 1830 1830
Width* mm 3670 3670
Depth mm 780 780
Weight kg 1002 1002
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 65.0 - 67.0 65.5 - 67.5
Airflow Rate l/s 10000 10278
Max External Static Pressure** Pa 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 5/8" 1 5/8"
Liquid Pipe Size in 7/8" 7/8"
Discharge Pipe Size in 1 3/8" 1 3/8"
R410A Refrigerant Base Charge kg 33 33
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A 20, 20 & 20 25, 20 & 20
Power Input (Cool - Heat) kW 25.35 - 27.35 27.85 - 30.60
Running Current (Cool - Heat) A 40.6 - 43.8 44.2 - 48.6
Starting Current A Soft Start Soft Start
Outdoor Unit £28,152 £28,621
Connection Kit £318 £318
Retail Price £28,470 £28,939*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-10°C to 43°C | heating operating range -20°C to 15.5°C| 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
VRF OutdoorSHRMi Heat Recovery Outdoor Units
ampair.co.uk | 01707 378 670 | [email protected] 101
VRF
Out
door
Outdoor Unit MMY-AP4014FT8-E MMY-AP4214FT8-E
Connection Kit RBM-BT24FE x 2 RBM-BT24FE x 2
PERF
ORM
ANCE
Horse Power 40 42
Nominal Cooling kW 112.0 118.0
Nominal Heating kW 127.0 132.0
Maximum Number of Indoor Units 48 48
Min - Max Connected Capacity Code** 28.0 - 54.0 29.4 - 56.7
EFFI
CIEN
CY
EER - COP 3.68 - 3.71 3.56 - 3.58
SEER - ESEER value (Office Profile) 6.56 - 6.90 6.38 - 6.72
SCOP - ESCOP (Value) 4.88 - 5.09 4.89 - 5.12
PHYS
ICAL
Number of Modules 3 3
Size of Modules HP 14HP + 14HP + 12HP 14HP + 14HP + 14HP
Height mm 1830 1830
Width* mm 3670 3670
Depth mm 780 780
Weight kg 1002 1002
SOU
ND
&
AIRF
LOW
Sound Pressure Level (Cool - Heat) dB(A) 66.5 - 68.5 67.0 - 69.0
Airflow Rate l/s 10555 10833
Max External Static Pressure** Pa 40 40
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1 5/8" 1 5/8"
Liquid Pipe Size in 7/8" 7/8"
Discharge Pipe Size in 1 3/8" 1 3/8"
R410A Refrigerant Base Charge kg 33 33
POW
ER
Power Supply V-Ph-Hz 400 - 3 - 50 400 - 3 - 50
Suggested Fuse Size A 25, 25 & 20 25, 25 & 25
Power Input (Cool - Heat) kW 30.40 - 34.25 33.10 - 36.90
Running Current (Cool - Heat) A 48.2 - 54.1 51.9 - 57.9
Starting Current A Soft Start Soft Start
Outdoor Unit £29,090 £29,559
Connection Kit £318 £318
Retail Price £29,408 £29,877*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range
-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
VRF OutdoorSHRMi Heat Recovery Outdoor Units
@amp_aircon | amp-air-conditioning 102
VRF
Out
door
2 Pipe Branch Joints & Header Pipes
Model Type Description Retail Price
RBM-BY55E Branch Pipe Kit Downstream capacity of less than 6.4HP £57
RBM-BY105E Branch Pipe Kit Downstream capacity of 6.4 to 14.2HP £70
RBM-BY205E Branch Pipe Kit Downstream capacity of 14.2 - 25.2HP £116
RBM-BY305E Branch Pipe Kit Downstream capacity of 25.2HP or more £154
RBM-HY1043E 4 Way Header Downstream capacity of less than 14.2HP £128
RBM-HY2043E 4 Way Header Downstream capacity of 14.2 to 25.2HP £102
RBM-HY1083E 8 Way Header Downstream capacity of less than 14.2HP £148
RBM-HY2083E 8 Way Header Downstream capacity of 14.2 - 25.2HP £143
3 Pipe Branch Joints & Header Pipes
Model Type Description Retail Price
RBM-BY55FE Branch Pipe Kit Downstream capacity of less than 6.4HP £65
RBM-BY105FE Branch Pipe Kit Downstream capacity of 6.4 to 14.2HP £89
RBM-BY205FE Branch Pipe Kit Downstream capacity of 14.2 - 25.2HP £133
RBM-BY305FE Branch Pipe Kit Downstream capacity of 25.2HP or more £219
RBM-HY1043FE 4 Way Header Downstream capacity of less than 14.2HP £130
RBM-HY2043FE 4 Way Header Downstream capacity of 14.2 to 25.2HP £130
RBM-HY1083FE 8 Way Header Downstream capacity of less than 14.2HP £214
RBM-HY2083FE 8 Way Header Downstream capacity of 14.2 - 25.2HP £210
Outdoor Connection Kits
Model Type Description Retail Price
RBM-BT14E Outdoor Connection Kit Y Connector less than 26HP SMMSe £127
RBM-BT24E Outdoor Connection Kit Y Connector greater than 26HP SMMSe £158
RBM-BT14FE Outdoor Connection Kit Y Connector less than 26HP SHRMi £128
RBM-BT24FE Outdoor Connection Kit Y Connector greater than 26HP SHRMi £159
VRF IndoorFlow Selector Units & Branch Pipes
Flow Selector Units RBM-Y1123FE RBM-Y1803FE RBM-Y2803FE
Connectible Indoor Unit Capacity Below 4.0HP 4.0 to below 6.4HP 6.4 to 10.0HP
Maximum number of indoor units 5 8 8
Height mm 190 190 200
Width mm 250 250 400
Depth mm 160 160 200
Weight Kg 5 5 8
Indoor Side Connection Size in 3/8” & 5/8" 3/8” & 5/8” 1/2” & 7/8”
Outdoor Side Connection Size in 3/8”, 1/2" & 5/8" 3/8”, 1/2” & 5/8” 1/2”, 3/4” & 5/8”
Connection Type Brazed Brazed Brazed
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Retail Price £531 £589 £923Multiple indoor units connected to the same flow selector unit will operate in the same mode using a single source of control | Flow selectors come complete with a 5m cable
for connection to associated indoor unit, this can be extended to 15m by using part RBC-FSEX15 £104 retail
ampair.co.uk | 01707 378 670 | [email protected] 103
VRF
Indo
or
VRF IndoorRange OverviewVRF Indoor
Page
Num
ber
Nominal Cooling kW 1.7 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0
Nominal Heating kW 1.9 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5
Indoor Unit Type 005* 007* 009* 012* 015* 018* 024* 027* 030* 036* 048* 056* 072* 096*
Capacity Code (HP) 0.6 0.8 1 1.25 1.7 2 2.5 3 3.2 4 5 6 8 10
106 1 Way Cassette ü ü ü ü ü ü
108 600mm2 Compact Cassette ü ü ü ü ü ü
110 4 Way Cassette ü ü ü ü ü ü ü ü ü ü
114 2 Way Cassette ü ü ü ü ü ü ü ü ü ü ü
118 Standard Ducted ü ü ü ü ü ü ü ü ü ü ü
122 Slim Ducted ü ü ü ü ü ü ü ü
126 High Static Ducted ü ü ü ü ü ü ü ü
129 High Static Ducted (high Flow) ü ü ü
130 3 Series Wall Mounted ü ü ü ü ü ü
132 4 Series Wall Mounted ü ü ü ü
134 Ceiling Suspended ü ü ü ü ü ü ü
137 Floor Mounted Cabinet ü ü ü ü ü ü ü
140 Floor Standing Chassis ü ü ü ü ü ü
142 Floor Mounted Console ü ü ü ü ü ü
144 Floor Mounted Bi Flow ü ü ü ü ü
148 Air to air with DX coil ü ü ü
150 Fresh air intake unit ü ü ü
005* models are only compatible with SMMSe outdoor units
ampair.co.uk | 01707 378 670 | [email protected] 103
@amp_aircon | amp-air-conditioning 104
VRF
Indo
or
VRF IndoorUK Cooling Capacities
IndoorUnitType
CapacityCode
Linear separation = 80mHigh Fan Speed Low Fan Speed
Sensible Cooling (kW) Total Cooling (kW) Sensible Cooling (kW) Total Cooling (kW)005* 0.6 1.17 1.31 0.87 1.05007* 0.8 1.53 1.70 1.13 1.36009* 1 1.89 2.16 1.40 1.73012* 1.25 2.44 2.82 1.80 2.26015* 1.7 2.88 3.47 2.13 2.78018* 2 3.60 4.32 2.67 3.46024* 2.5 4.14 5.48 3.07 4.38027* 3 4.96 6.17 3.67 4.94030* 3.2 5.59 6.94 4.13 5.55036* 4 6.94 8.64 5.13 6.91048* 5 8.83 10.80 6.53 8.64056* 6 9.91 12.34 7.33 9.87072* 8 13.42 17.28 9.93 13.82096* 10 16.49 21.60 12.20 17.28
IndoorUnitType
CapacityCode
Linear separation = 50mHigh Fan Speed Low Fan Speed
Sensible Cooling (kW) Total Cooling (kW) Sensible Cooling (kW) Total Cooling (kW)005* 0.6 1.19 1.41 0.88 1.12007* 0.8 1.56 1.82 1.15 1.46009* 1 1.93 2.31 1.43 1.85012* 1.25 2.48 3.03 1.84 2.42015* 1.7 2.94 3.72 2.17 2.98018* 2 3.67 4.63 2.72 3.70024* 2.5 4.22 5.87 3.12 4.70027* 3 5.05 6.61 3.73 5.29030* 3.2 5.69 7.44 4.21 5.95036* 4 7.06 9.26 5.23 7.41048* 5 8.99 11.57 6.65 9.26056* 6 10.09 13.23 7.47 10.58072* 8 13.67 18.52 10.12 14.81096* 10 16.79 23.15 12.42 18.52
IndoorUnitType
CapacityCode
Linear separation = 20mHigh Fan Speed Low Fan Speed
Sensible Cooling (kW) Total Cooling (kW) Sensible Cooling (kW) Total Cooling (kW)005* 0.6 1.21 1.53 0.90 1.22007* 0.8 1.59 1.98 1.17 1.58009* 1 1.96 2.51 1.45 2.01012* 1.25 2.53 3.29 1.87 2.63015* 1.7 2.99 4.04 2.21 3.23018* 2 3.74 5.03 2.76 4.02024* 2.5 4.30 6.37 3.18 5.10027* 3 5.14 7.18 3.80 5.75030* 3.2 5.79 8.08 4.29 6.46036* 4 7.19 10.06 5.32 8.04048* 5 9.15 12.57 6.77 10.06056* 6 10.27 14.37 7.60 11.49072* 8 13.92 20.11 10.30 16.09096* 10 17.09 25.14 12.65 20.11
The unit capacities shown is the booklet are all nominal figures. The tables below show the cooling capacities at various design conditions. These figures are the approximate capacities for the SMMSe systems with 4 way cassette indoor units. Figures for the SHRMi / other indoors will be similar. 005* models are only compatible with SMMSe outdoor units
ampair.co.uk | 01707 378 670 | [email protected] 105
VRF
Indo
or
VRF IndoorUK Heating CapacitiesVRF Indoor
The unit capacities shown is the booklet are all nominal figures. The tables below show the heating capacities at various design conditions. These figures are the approximate capacities for the SMMSe systems with 4 way cassette indoor units. Figures for the SHRMi / other indoors will be similar. 005* models are only compatible with SMMSe outdoor units
Indoor Unit Type Capacity Code
Linear separation = 20m
High Fan Speed Low Fan Speed
005* 0.6 1.50 1.20007* 0.8 1.97 1.58009* 1 2.53 2.02012* 1.25 3.17 2.54015* 1.7 3.95 3.16018* 2 4.98 3.98024* 2.5 6.34 5.07027* 3 7.11 5.69030* 3.2 7.90 6.32036* 4 9.87 7.90048* 5 12.64 10.11056* 6 14.22 11.38072* 8 19.75 15.80096* 10 24.88 19.91
Indoor Unit Type Capacity Code
Linear separation = 50m
High Fan Speed Low Fan Speed
005* 0.6 1.47 1.17007* 0.8 1.93 1.54009* 1 2.47 1.97012* 1.25 3.10 2.48015* 1.7 3.86 3.09018* 2 4.86 3.89024* 2.5 6.19 4.95027* 3 6.94 5.55030* 3.2 7.71 6.17036* 4 9.64 7.71048* 5 12.34 9.87056* 6 13.88 11.11072* 8 19.28 15.43096* 10 24.30 19.44
Indoor Unit Type Capacity Code
Linear separation = 80m
High Fan Speed Low Fan Speed
005* 0.6 1.43 1.14007* 0.8 1.88 1.51009* 1 2.41 1.93012* 1.25 3.02 2.42015* 1.7 3.76 3.01018* 2 4.74 3.79024* 2.5 6.04 4.83027* 3 6.77 5.42030* 3.2 7.53 6.02036* 4 9.41 7.53048* 5 12.04 9.64056* 6 13.55 10.84072* 8 18.82 15.05096* 10 23.71 18.97
VRF Indoor1 Way Cassettes
@amp_aircon | amp-air-conditioning 106
VRF
Indo
or
Indoor Unit MMU-AP0074YH1-E MMU-AP0094YH1-E MMU-AP0124YH1-E
Grille RBC-UY135PG RBC-UY135PG RBC-UY135PG
PERF
ORM
ANCE Capacity Code 0.8 1 1.25
Nominal Cooling kW 2.2 2.8 3.6
Nominal Heating kW 2.5 3.2 4.0
PHYS
ICAL
Height - Unit (Grille) mm 235 (18) 235 (18) 235 (18)
Width - Unit (Grille) mm 850 (1050) 850 (1050) 850 (1050)
Depth - Unit (Grille) mm 400 (470) 400 (470) 400 (470)
Weight - Unit (Grille) kg 22 (3.5) 22 (3.5) 22 (3.5)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 34 - 39 - 42 34 - 39 - 42 34 - 39 - 42
Airflow Rate (lo-me-hi) l/s 117 - 133 - 150 117 - 133 - 150 117 - 133 - 150
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 25 nom. 25 nom. 25 nom.
Internal Lift Pump Yes (350mm)* Yes (350mm)* Yes (350mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.053 0.053 0.053
Running Current A 0.24 0.24 0.24
Starting Current A 0.60 0.60 0.60
Indoor Unit £1,100 £1,135 £1,169
Grille £226 £226 £226
Retail Price £1,326 £1,361 £1,395
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 350 from the underside of the ceiling tile
VRF Indoor1 Way Cassettes
ampair.co.uk | 01707 378 670 | [email protected] 107
VRF
Indo
or
Indoor Unit MMU-AP0154SH1-E MMU-AP0184SH1-E MMU-AP0244SH1-E
Grille RBC-US21PG-E RBC-US21PG-E RBC-US21PG-E
PERF
ORM
ANCE Capacity Code 1.7 2 2.5
Nominal Cooling kW 4.5 5.6 7.1
Nominal Heating kW 5.0 6.3 8.0
PHYS
ICAL
Height - Unit (Grille) mm 200 (20) 200 (20) 200 (20)
Width - Unit (Grille) mm 1000 (1230) 1000 (1230) 1000 (1230)
Depth - Unit (Grille) mm 710 (800) 710 (800) 710 (800)
Weight - Unit (Grille) kg 21 (5.5) 21 (5.5) 22 (5.5)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 32 - 35 - 37 34 - 36 - 38 37 - 41 - 45
Airflow Rate (lo-me-hi) l/s 175 - 192 - 208 183 - 200 - 217 225 - 267 - 317
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2” 5/8”
Liquid Pipe Size in 1/4” 1/4” 3/8”
Drain Connection mm 25 nom. 25 nom. 25 nom.
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.042 0.046 0.075
Running Current A 0.34 0.37 0.62
Starting Current A 0.51 0.54 0.80
Indoor Unit £1,037 £1,189 £1,267
Grille £310 £310 £310
Retail Price £1,347 £1,499 £1,577Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out
for fresh air intake
VRF Indoor4 Way Compact Cassettes
@amp_aircon | amp-air-conditioning 108
VRF
Indo
or
Indoor Unit MMU-AP0056MH1-E MMU-AP0074MH1-E MMU-AP0094MH1-E
Grille RBC-UM11PG(W)E RBC-UM11PG(W)E RBC-UM11PG(W)E
PERF
ORM
ANCE Capacity Code 0.6 0.8 1
Nominal Cooling kW 1.7 2.2 2.8
Nominal Heating kW 1.9 2.5 3.2
PHYS
ICAL
Height - Unit (Grille) mm 268 (27) 268 (27) 268 (27)
Width - Unit (Grille) mm 575 (700) 575 (700) 575 (700)
Depth - Unit (Grille) mm 575 (700) 575 (700) 575 (700)
Weight - Unit (Grille) kg 17 (3.0) 17 (3.0) 17 (3.0)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 28 - 32 - 35 28 - 32 - 36 28 - 33 - 37
Airflow Rate (lo-me-hi) l/s 105 - 128 - 135 105 - 128 - 153 105 - 130 - 158
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 25od 25od 25od
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.034 0.034 0.036
Running Current A 0.28 0.28 0.30
Starting Current A 0.49 0.49 0.52
Indoor Unit £704 £705 £757
Grille £200 £200 £200
Retail Price £904 £905 £957Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |
Knock out for fresh air intake 64 x 64 | 0056 model is only compatible with SMMSe outdoor units
VRF Indoor4 Way Compact Cassettes
ampair.co.uk | 01707 378 670 | [email protected] 109
VRF
Indo
or
Indoor Unit MMU-AP0124MH1-E MMU-AP0154MH1-E MMU-AP0184MH1-E
Grille RBC-UM11PG(W)E RBC-UM11PG(W)E RBC-UM11PG(W)E
PERF
ORM
ANCE Capacity Code 1.25 1.7 2
Nominal Cooling kW 3.6 4.5 5.6
Nominal Heating kW 4.0 5.0 6.3
PHYS
ICAL
Height - Unit (Grille) mm 268 (27) 268 (27) 268 (27)
Width - Unit (Grille) mm 575 (700) 575 (700) 575 (700)
Depth - Unit (Grille) mm 575 (700) 575 (700) 575 (700)
Weight - Unit (Grille) kg 17 (3.0) 17 (3.0) 17 (3.0)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 29 - 33 - 37 30 - 35 - 40 34 - 39 - 44
Airflow Rate (lo-me-hi) l/s 112 - 140 - 165 130 - 153 - 183 145 - 178 - 212
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 1/2” 1/2”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 25od 25od 25od
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.038 0.041 0.052
Running Current A 031 0.34 0.42
Starting Current A 0.54 0.59 0.73
Indoor Unit £789 £831 £885
Grille £200 £200 £200
Retail Price £989 £1,031 £1,085Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |
Knock out for fresh air intake 64 x 64 | 0056 model is only compatible with SMMSe outdoor units
RBC-AMS54E-ES £105 Retail
VRF Indoor4 Way Cassettes
@amp_aircon | amp-air-conditioning 110
VRF
Indo
or
Indoor Unit MMU-AP0094HP1-E MMU-AP0124HP1-E MMU-AP0154HP1-E
Grille RBC-U31PGP(W)-E RBC-U31PGP(W)-E RBC-U31PGP(W)-E
PERF
ORM
ANCE Capacity Code 1 1.25 1.7
Nominal Cooling kW 2.8 3.6 4.5
Nominal Heating kW 3.2 4.0 5.0
PHYS
ICAL
Height - Unit (Grille) mm 256 (30) 256 (30) 256 (30)
Width - Unit (Grille) mm 840 (950) 840 (950) 840 (950)
Depth - Unit (Grille) mm 840 (950) 840 (950) 840 (950)
Weight - Unit (Grille) kg 20 (4.0) 20 (4.0) 20 (4.0)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 27 - 29 - 30 27 - 29 - 30 27 - 29 - 31
Airflow Rate (lo-me-hi) l/s 189 - 203 - 222 189 - 203 - 222 219 - 231 - 258
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8” 1/2”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 25od 25od 25od
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.021 0.021 0.023
Running Current A 0.23 0.23 0.27
Starting Current A 0.30 0.30 0.33
Indoor Unit £806 £830 £876
Grille £154 £154 £154
Retail Price £960 £984 £1,030Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |
Knock out for fresh air intake 64 x 57
VRF Indoor4 Way Cassettes
ampair.co.uk | 01707 378 670 | [email protected] 111
VRF
Indo
or
Indoor Unit MMU-AP0184HP1-E MMU-AP0244HP1-E
Grille RBC-U31PGP(W)-E RBC-U31PGP(W)-E
PERF
ORM
ANCE Capacity Code 2 2.5
Nominal Cooling kW 5.6 7.1
Nominal Heating kW 6.3 8.0
PHYS
ICAL
Height - Unit (Grille) mm 256 (30) 256 (30)
Width - Unit (Grille) mm 840 (950) 840 (950)
Depth - Unit (Grille) mm 840 (950) 840 (950)
Weight - Unit (Grille) kg 20 (4.0) 20 (4.0)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 27 - 29 - 32 28 - 31 - 35
Airflow Rate (lo-me-hi) l/s 222 - 256 - 292 222 - 256 - 358
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 5/8”
Liquid Pipe Size in 1/4” 3/8”
Drain Connection mm 25od 25od
Internal Lift Pump Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.026 0.036
Running Current A 0.29 0.38
Starting Current A 0.36 0.42
Indoor Unit £899 £939
Grille £154 £154
Retail Price £1,053 £1,093Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |
Knock out for fresh air intake 64 x 57
RBC-AS41E £70 Retail
VRF Indoor4 Way Cassettes
@amp_aircon | amp-air-conditioning 112
VRF
Indo
or
Indoor Unit MMU-AP0274HP1-E MMU-AP0304HP1-E MMU-AP0364HP1-E
Grille RBC-U31PGP(W)-E RBC-U31PGP(W)-E RBC-U31PGP(W)-E
PERF
ORM
ANCE Capacity Code 3 3.2 4
Nominal Cooling kW 8.0 9.0 11.2
Nominal Heating kW 9.0 10.0 12.5
PHYS
ICAL
Height - Unit (Grille) mm 256 (30) 256 (30) 319 (30)
Width - Unit (Grille) mm 840 (950) 840 (950) 840 (950)
Depth - Unit (Grille) mm 840 (950) 840 (950) 840 (950)
Weight - Unit (Grille) kg 20 (4.0) 20 (4.0) 25 (4.0)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 28 - 31 - 35 30 - 33 - 38 32 - 38 - 43
Airflow Rate (lo-me-hi) l/s 222 - 256 - 358 236 - 306 - 367 297 - 397 - 547
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8” 3/8”
Drain Connection mm 25od 25od 25od
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.036 0.043 0.088
Running Current A 0.38 0.43 0.73
Starting Current A 0.42 0.59 0.87
Indoor Unit £1,117 £1,222 £1,292
Grille £154 £154 £154
Retail Price £1,271 £1,376 £1,446Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |
Knock out for fresh air intake 64 x 57
VRF Indoor4 Way Cassettes
ampair.co.uk | 01707 378 670 | [email protected] 113
VRF
Indo
or
Indoor Unit MMU-AP0484HP1-E MMU-AP0564HP1-E
Grille RBC-U31PGP(W)-E RBC-U31PGP(W)-E
PERF
ORM
ANCE Capacity Code 5 6
Nominal Cooling kW 14.0 16.0
Nominal Heating kW 16.0 18.0
PHYS
ICAL
Height - Unit (Grille) mm 319 (30) 319 (30)
Width - Unit (Grille) mm 840 (950) 840 (950)
Depth - Unit (Grille) mm 840 (950) 840 (950)
Weight - Unit (Grille) kg 25 (4.0) 25 (4.0)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 33 - 38 - 46 33 - 40 - 46
Airflow Rate (lo-me-hi) l/s 314 - 397 - 592 342 - 422 - 592
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8”
Drain Connection mm 25od 25od
Internal Lift Pump Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.112 0.112
Running Current A 0.88 0.88
Starting Current A 1.23 1.26
Indoor Unit £1,350 £1,523
Grille £154 £154
Retail Price £1,504 £1,677Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |
Knock out for fresh air intake 64 x 57
RBC-AMT32E £50 Retail
VRF Indoor2 Way Cassettes
@amp_aircon | amp-air-conditioning 114
VRF
Indo
or
Indoor Unit MMU-AP0072WH1-E MMU-AP0092WH1-E MMU-AP0122WH1-E
Grille RBC-UW283PG(W)-E RBC-UW283PG(W)-E RBC-UW283PG(W)-E
PERF
ORM
ANCE Capacity Code 0.8 1 1.25
Nominal Cooling kW 2.2 2.8 3.6
Nominal Heating kW 2.5 3.2 4.0
PHYS
ICAL
Height - Unit (Grille) mm 295 (20) 295 (20) 295 (20)
Width - Unit (Grille) mm 815 (1050) 815 (1050) 815 (1050)
Depth - Unit (Grille) mm 570 (680) 570 (680) 570 (680)
Weight - Unit (Grille) kg 19 (10) 19 (10) 19 (10)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 30 - 32 - 34 30 - 32 - 34 30 - 32 - 34
Airflow Rate (lo-me-hi) l/s 125 - 138 - 155 125 - 138 - 155 125 - 138 - 155
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 25 nom. 25 nom. 25 nom.
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.029 0.029 0.029
Running Current A 0.23 0.23 0.23
Starting Current A 0.35 0.35 0.35
Indoor Unit £885 £915 £942
Grille £221 £221 £221
Retail Price £1,106 £1,136 £1,163Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out
for fresh air intake
MMU-AP0242WH1-E
VRF Indoor2 Way Cassettes
ampair.co.uk | 01707 378 670 | [email protected] 115
VRF
Indo
or
Indoor Unit MMU-AP0152WH1-E MMU-AP0182WH1-E MMU-AP0242WH1-E
Grille RBC-UW283PG(W)-E RBC-UW803PG(W)-E RBC-UW803PG(W)-E
PERF
ORM
ANCE Capacity Code 1.7 2 2.5
Nominal Cooling kW 4.5 5.6 7.1
Nominal Heating kW 5.0 6.3 8.0
PHYS
ICAL
Height - Unit (Grille) mm 295 (20) 345 (20) 345 (20)
Width - Unit (Grille) mm 815 (1050) 1180 (1415) 1180 (1415)
Depth - Unit (Grille) mm 570 (680) 570 (680) 570 (680)
Weight - Unit (Grille) kg 19 (10) 26 (14) 26 (14)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 30 - 33 - 35 30 - 33 - 35 33 - 35 - 38
Airflow Rate (lo-me-hi) l/s 125 - 148 - 167 172 - 208 - 250 205 - 233 - 292
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2” 5/8”
Liquid Pipe Size in 1/4” 1/4” 3/8”
Drain Connection mm 25 nom. 25 nom. 25 nom.
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.030 0.044 0.054
Running Current A 0.24 0.32 0.39
Starting Current A 0.36 0.48 0.59
Indoor Unit £980 £1,072 £1,138
Grille £221 £294 £294
Retail Price £1,201 £1,366 £1,432Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out
for fresh air intake
RBC-AMS54E-ES £105 Retail
VRF Indoor2 Way Cassettes
@amp_aircon | amp-air-conditioning 116
VRF
Indo
or
Indoor Unit MMU-AP0272WH1-E MMU-AP0302WH1-E MMU-AP0362WH1-E
Grille RBC-UW803PG(W)-E RBC-UW803PG(W)-E RBC-UW1403PG(W)-E
PERF
ORM
ANCE Capacity Code 3 3.2 4
Nominal Cooling kW 8.0 9.0 11.2
Nominal Heating kW 9.0 10.0 12.5
PHYS
ICAL
Height - Unit (Grille) mm 345 (20) 345 (20) 345 (20)
Width - Unit (Grille) mm 1180 (1415) 1180 (1415) 1600 (1835)
Depth - Unit (Grille) mm 570 (680) 570 (680) 570 (680)
Weight - Unit (Grille) kg 26 (14) 26 (14) 36 (14)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 33 - 35 - 38 34 - 37 - 40 36 - 39 - 42
Airflow Rate (lo-me-hi) l/s 205 - 233 - 292 217 - 250 - 350 328 - 398 - 483
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8” 3/8”
Drain Connection mm 25 nom. 25 nom. 25 nom.
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.054 0.064 0.073
Running Current A 0.39 0.46 0.48
Starting Current A 0.59 0.69 0.72
Indoor Unit £1,310 £1,323 £1,589
Grille £294 £294 £336
Retail Price £1,604 £1,617 £1,925Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out
for fresh air intake
MMU-AP0242WH1-E
VRF Indoor2 Way Cassettes
ampair.co.uk | 01707 378 670 | [email protected] 117
VRF
Indo
or
Indoor Unit MMU-AP0482WH1-E MMU-AP0562WH1-E
Grille RBC-UW1403PG(W)-E RBC-UW1403PG(W)-E
PERF
ORM
ANCE Capacity Code 5 6
Nominal Cooling kW 14.0 16.0
Nominal Heating kW 16.0 18.0
PHYS
ICAL
Height - Unit (Grille) mm 345 (20) 345 (20)
Width - Unit (Grille) mm 1600 (1835) 1600 (1835)
Depth - Unit (Grille) mm 570 (680) 570 (680)
Weight - Unit (Grille) kg 36 (14) 36 (14)
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 37 - 40 - 43 39 - 42 - 46
Airflow Rate (lo-me-hi) l/s 342 - 412 - 500 367 - 438 - 567
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8”
Drain Connection mm 25 nom. 25 nom.
Internal Lift Pump Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.088 0.117
Running Current A 0.57 0.75
Starting Current A 0.86 1.13
Indoor Unit £1,743 £1,913
Grille £336 £336
Retail Price £2,079 £2,249Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out
for fresh air intake
RBC-AMS41E £66 Retail
VRF IndoorStandard Ducted
@amp_aircon | amp-air-conditioning 118
VRF
Indo
or
Indoor Unit MMD-AP0076BHP1-E MMD-AP0096BHP1-E MMD-AP0126BHP1-E
Spigot Kit AMP-RAVBTE-2DUCT AMP-RAVBTE-2DUCT AMP-RAVBTE-2DUCT
PERF
ORM
ANCE Capacity Code 0.8 1 1.25
Nominal Cooling kW 2.2 2.8 3.6
Nominal Heating kW 2.5 3.2 4.0
PHYS
ICAL
Height mm 275 275 275
Width mm 700 700 700
Depth mm 750 750 750
Weight kg 23 23 23
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 23 - 26 - 29 23 - 26 - 30 23 - 26 - 30
Airflow Rate (lo-me-hi) l/s 100 - 125 - 150 108 - 133 - 158 108 - 133 - 158
Static Pressure (standard (min-max)) Pa 30 (30 - 120) 30 (30 - 120) 30 (30 - 120)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 25 25 25
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.038 0.043 0.043
Running Current A 0.26 0.29 0.29
Starting Current A 0.45 0.5 0.5
Indoor Unit £776 £754 £796
Spigot Kit £40 £40 £40
Retail Price £816 £794 £836Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the bottom of the unit | as standard units come with rectangular air
outlets, 640 x 180 (0076 - 0186), 940 x 180 (0246 - 0306), 1340 x 180 (0366 - 0566). The optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | Return air filter as standard
MMD-AP0306BHP1-E
VRF IndoorStandard Ducted
ampair.co.uk | 01707 378 670 | [email protected] 119
VRF
Indo
or
Indoor Unit MMD-AP0156BHP1-E MMD-AP0186BHP1-E
Spigot Kit AMP-RAVBTE-2DUCT AMP-RAVBTE-2DUCT
PERF
ORM
ANCE Capacity Code 1.7 2
Nominal Cooling kW 4.5 5.6
Nominal Heating kW 5.0 6.3
PHYS
ICAL
Height mm 275 275
Width mm 700 700
Depth mm 750 750
Weight kg 23 23
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 25 - 29 - 33 25 - 29 - 33
Airflow Rate (lo-me-hi) l/s 150 - 183 - 217 150 - 183 - 217
Static Pressure (standard (min-max)) Pa 30 (30 - 120) 30 (30 - 120)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2”
Liquid Pipe Size in 1/4” 1/4”
Drain Connection mm 25 25
Internal Lift Pump Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.062 0.062
Running Current A 0.42 0.42
Starting Current A 0.73 0.73
Indoor Unit £819 £875
Spigot Kit £40 £40
Retail Price £859 £915Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the bottom of the unit | as standard units come with rectangular air
outlets, 640 x 180 (0076 - 0186), 940 x 180 (0246 - 0306), 1340 x 180 (0366 - 0566). The optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | Return air filter as standard
RBC-AS41E £70 Retail
VRF IndoorStandard Ducted
@amp_aircon | amp-air-conditioning 120
VRF
Indo
or
Indoor Unit MMD-AP0246BHP1-E MMD-AP0276BHP1-E MMD-AP0306BHP1-E
Spigot Kit AMP-RAVBTE-3DUCT AMP-RAVBTE-3DUCT AMP-RAVBTE-3DUCT
PERF
ORM
ANCE Capacity Code 2.5 3 3.2
Nominal Cooling kW 7.1 8.0 9.0
Nominal Heating kW 8.0 9.0 10.0
PHYS
ICAL
Height mm 275 275 275
Width mm 1000 1000 1000
Depth mm 750 750 750
Weight kg 30 30 30
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 27 - 31 - 36 27 - 31 - 36 27 - 31 - 36
Airflow Rate (lo-me-hi) l/s 242 - 267 - 333 242 - 267 - 333 258 - 300 - 350
Static Pressure (standard (min-max)) Pa 40 (30 - 120) 40 (30 - 120) 40 (30 - 120)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8” 3/8”
Drain Connection mm 25 25 25
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.077 0.077 0.094
Running Current A 0.52 0.52 0.61
Starting Current A 0.90 0.90 1.06
Indoor Unit £914 £1,013 £1,082
Spigot Kit £54 £54 £54
Retail Price £968 £1,067 £1,136Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the bottom of the unit | as standard units come with rectangular air
outlets, 640 x 180 (0076 - 0186), 940 x 180 (0246 - 0306), 1340 x 180 (0366 - 0566). The optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | Return air filter as standard
MMD-AP0306BHP1-E
VRF IndoorStandard Ducted
ampair.co.uk | 01707 378 670 | [email protected] 121
VRF
Indo
or
Indoor Unit MMD-AP0366BHP1-E MMD-AP0486BHP1-E MMD-AP0566BHP1-E
Spigot Kit AMP-RAVBTE-4DUCT AMP-RAVBTE-4DUCT AMP-RAVBTE-4DUCT
PERF
ORM
ANCE Capacity Code 4 5 6
Nominal Cooling kW 11.2 14.0 16.0
Nominal Heating kW 12.5 16.0 18.0
PHYS
ICAL
Height mm 275 275 275
Width mm 1400 1400 1400
Depth mm 750 750 750
Weight kg 40 40 40
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 33 - 36 - 40 33 - 36 - 40 33 - 36 - 40
Airflow Rate (lo-me-hi) l/s 383 - 450 - 533 417 - 483 - 583 417 - 483 - 583
Static Pressure (standard (min-max)) Pa 50 (30 - 120) 50 (30 - 120) 50 (30 - 120)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8” 3/8”
Drain Connection mm 25 25 25
Internal Lift Pump Yes (850mm)* Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.172 0.198 0.198
Running Current A 1.07 1.23 1.23
Starting Current A 1.85 2.13 2.13
Indoor Unit £1,240 £1,327 £1,409
Spigot Kit £67 £67 £67
Retail Price £1,307 £1,394 £1,476Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the bottom of the unit | as standard units come with rectangular air
outlets, 640 x 180 (0076 - 0186), 940 x 180 (0246 - 0306), 1340 x 180 (0366 - 0566). The optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | Return air filter as standard
RBC-AMS54E-ES £105 Retail
VRF IndoorSlim Ducted
@amp_aircon | amp-air-conditioning 122
VRF
Indo
or
Indoor Unit MMD-AP0056SPH1-E MMD-AP0074SPH1-E
Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 0.6 0.8
Nominal Cooling kW 1.7 2.2
Nominal Heating kW 1.9 2.5
PHYS
ICAL
Height mm 210 210
Width mm 845 845
Depth mm 645 645
Weight kg 22 22
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi)** dB(A) 30 - 33 - 36 / 24 - 26 - 27 30 - 33 - 36 / 24 - 26 - 28
Airflow Rate (lo-me-hi) l/s 112 - 130 - 137 111 - 131 - 150
Static Pressure (standard (min-max)) Pa 6 (6-46) 6 (6-46)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4”
Drain Connection mm 32 od 25 id 32 od 25 id
Internal Lift Pump Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.039 0.039
Running Current A 0.29 0.29
Starting Current A 0.51 0.51
Indoor Unit £693 £693
Spigot Kit n/a n/a
Retail Price £693 £693Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the bottom of the unit | ** Bottom return / rear return | Unit comes as
bottom return as standard, can be changed to rear return | Knock out for fresh air intake | Return air filter as standard | 0056 model only compatible with SMMSe outdoor units
MMD-AP0074SPH1-E
VRF IndoorSlim Ducted
ampair.co.uk | 01707 378 670 | [email protected] 123
VRF
Indo
or
Indoor Unit MMD-AP0094SPH1-E MMD-AP0124SPH1-E
Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 1 1.25
Nominal Cooling kW 2.8 3.6
Nominal Heating kW 3.2 4.0
PHYS
ICAL
Height mm 210 210
Width mm 845 845
Depth mm 645 645
Weight kg 22 22
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 30 - 33 - 36 / 24 - 26 - 28 32 - 35 - 38 / 25 - 27 - 29
Airflow Rate (lo-me-hi) l/s 111 - 131 - 150 125 - 144 - 167
Static Pressure (standard (min-max)) Pa 6 (6-46) 5 (5-45)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4”
Drain Connection mm 32 od 25 id 32 od 25 id
Internal Lift Pump Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.039 0.043
Running Current A 0.29 0.31
Starting Current A 0.51 0.54
Indoor Unit £702 £722
Spigot Kit n/a n/a
Retail Price £702 £722Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the bottom of the unit | ** Bottom return / rear return | Unit comes as
bottom return as standard, can be changed to rear return | Knock out for fresh air intake | Return air filter as standard | 0056 model only compatible with SMMSe outdoor units
RBC-AS41E £70 Retail
VRF IndoorSlim Ducted
@amp_aircon | amp-air-conditioning 124
VRF
Indo
or
Indoor Unit MMD-AP0154SPH1-E MMD-AP0184SPH1-E
Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 1.7 2
Nominal Cooling kW 4.5 5.6
Nominal Heating kW 5.0 6.3
PHYS
ICAL
Height mm 210 210
Width mm 845 845
Depth mm 645 645
Weight kg 23 23
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi)** dB(A) 33 - 36 - 39 / 28 - 30 - 32 36 - 38 - 40 / 29 - 31 - 33
Airflow Rate (lo-me-hi) l/s 144 - 167 - 192 161 - 189 - 217
Static Pressure (standard (min-max)) Pa 5 (5 - 45) 4 (4 - 44)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2”
Liquid Pipe Size in 1/4” 1/4”
Drain Connection mm 32 od 25 id 32 od 25 id
Internal Lift Pump Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.045 0.054
Running Current A 0.32 0.39
Starting Current A 0.56 0.68
Indoor Unit £752 £790
Spigot Kit n/a n/a
Retail Price £752 £790Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the bottom of the unit | ** Bottom return / rear return | Unit comes as
bottom return as standard, can be changed to rear return | Knock out for fresh air intake | Return air filter as standard | 0056 model only compatible with SMMSe outdoor units
MMD-AP0074SPH1-E
VRF IndoorSlim Ducted
ampair.co.uk | 01707 378 670 | [email protected] 125
VRF
Indo
or
Indoor Unit MMD-AP0244SPH1-E MMD-AP0274SPH1-E
Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 2.5 3
Nominal Cooling kW 7.1 8.0
Nominal Heating kW 8.0 9.0
PHYS
ICAL
Height mm 210 210
Width mm 1140 1140
Depth mm 645 645
Weight kg 29 29
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 44 - 47 - 49 / 33 - 36 - 38 44 - 47 - 49 / 33 - 36 - 38
Airflow Rate (lo-me-hi) l/s 250 - 278 - 300 250 - 278 - 300
Static Pressure (standard (min-max)) Pa 42 (2 - 42) 42 (2 - 42)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8”
Drain Connection mm 32 od 25 id 32 od 25 id
Internal Lift Pump Yes (850mm)* Yes (850mm)*
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.105 0.105
Running Current A 0.75 0.75
Starting Current A 1.13 1.13
Indoor Unit £853 £921
Spigot Kit n/a n/a
Retail Price £853 £921Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 850 from the bottom of the unit | ** Bottom return / rear return | Unit comes as
bottom return as standard, can be changed to rear return | Knock out for fresh air intake | Return air filter as standard | 0056 model only compatible with SMMSe outdoor units
RBC-AMS41E £66 Retail
VRF IndoorHigh Static Ducted
@amp_aircon | amp-air-conditioning 126
VRF
Indo
or
Indoor Unit MMD-AP0186HP1-E MMD-AP0246HP1-E MMD-AP0276HP1-E
Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 2 2.5 3
Nominal Cooling kW 5.6 7.1 8.0
Nominal Heating kW 6.3 8.0 9.0
PHYS
ICAL
Height mm 298 298 298
Width mm 1000 1000 1000
Depth mm 750 750 750
Weight kg 34 34 34
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 30 - 32 - 37 31 - 34 - 38 31 - 34 - 38
Airflow Rate (lo-me-hi) l/s 152 - 183 - 222 222 - 269 - 333 222 - 269 - 333
Static Pressure (standard (min-max)) Pa 100 (50 - 200) 100 (50 - 200) 100 (50 - 200)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 5/8” 5/8”
Liquid Pipe Size in 1/4” 3/8” 3/8”
Drain Connection mm 25 nom. 25 nom. 25 nom.
Internal Lift Pump Yes Yes Yes
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.085 0.115 0.115
Running Current A 0.52 0.70 1.17
Starting Current A 0.78 1.05 1.75
Indoor Unit £1,028 £1,133 £1,182
Spigot Kit n/a n/a n/a
Retail Price £1,028 £1,133 £1,182Communication cable - 2 core non polar 1.5mm2 screened cable | Unit does not come with a filter | Air outlet dimensions 180 x 940 (0186 - 0276), 180 x 1340 (0366 - 0566),
TBC (0762 - 0966)
MMD-AP0486HP1-E
VRF IndoorHigh Static Ducted
ampair.co.uk | 01707 378 670 | [email protected] 127
VRF
Indo
or
Indoor Unit MMD-AP0366HP1-E MMD-AP0486HP1-E MMD-AP0566HP1-E
Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 4 5 6
Nominal Cooling kW 11.2 14.0 16.0
Nominal Heating kW 12.5 16.0 18.0
PHYS
ICAL
Height mm 298 298 298
Width mm 1400 1400 1400
Depth mm 750 750 750
Weight kg 43 43 43
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 34 - 37 - 41 35 - 40 - 42 37 - 42 - 45
Airflow Rate (lo-me-hi) l/s 372 - 433 - 533 394 - 483 - 583 461 - 567 - 667
Static Pressure (standard (min-max)) Pa 100 (50 - 200) 100 (50 - 200) 100 (50 - 200)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8” 3/8”
Drain Connection mm 25 nom. 25 nom. 25 nom.
Internal Lift Pump Yes Yes Yes
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.198 0.230 0.290
Running Current A 1.17 1.34 1.68
Starting Current A 1.75 2.01 2.51
Indoor Unit £1,239 £1,371 £1,467
Spigot Kit n/a n/a n/a
Retail Price £1,239 £1,371 £1,467Communication cable - 2 core non polar 1.5mm2 screened cable | Unit does not come with a filter | Air outlet dimensions 180 x 940 (0186 - 0276), 180 x 1340 (0366 - 0566),
TBC (0762 - 0966)
RBC-AMS54E-ES £105 Retail
VRF IndoorHigh Static Ducted
@amp_aircon | amp-air-conditioning 128
VRF
Indo
or
Indoor Unit MMD-AP0726HP1-E MMD-AP0966HP1-E
Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 8 10
Nominal Cooling kW 22.4 28.0
Nominal Heating kW 25.0 31.5
PHYS
ICAL
Height mm 448 448
Width mm 1400 1400
Depth mm 900 900
Weight kg 97 97
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 36 - 40 - 44 38 - 42 - 46
Airflow Rate l/s 1056 1333
Static Pressure (standard (min-max)) Pa 150 (50 - 250) 150 (50 - 250)
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 7/8” 7/8”
Liquid Pipe Size in 1/2” 1/2”
Drain Connection mm 25 nom. 25 nom.
Internal Lift Pump No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 10 10
Power Input kW 0.540 0.790
Running Current A 2.80 3.75
Starting Current A 7.80 7.80
Indoor Unit £2,476 £2,616
Spigot Kit n/a n/a
Retail Price £2,476 £2,616Communication cable - 2 core non polar 1.5mm2 screened cable | Unit does not come with a filter | Air outlet dimensions 180 x 940 (0186 - 0276), 180 x 1340 (0366 - 0566),
TBC (0762 - 0966)
VRF IndoorHigh Static Ducted - High Flow
ampair.co.uk | 01707 378 670 | [email protected] 129
VRF
Indo
or
Indoor Unit MMD-AP0364H-EU MMD-AP0484H-EU MMD-AP0564H-EU
Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 4 5 6
Nominal Cooling kW 11.2 14.0 16.0
Nominal Heating kW 12.5 16.0 18.0
PHYS
ICAL
Height mm TBC TBC TBC
Width mm TBC TBC TBC
Depth mm TBC TBC TBC
Weight kg TBC TBC TBC
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) TBC TBC TBC
Airflow Rate (lo-me-hi) l/s TBC TBC TBC
Static Pressure (standard (min-max)) Pa TBC TBC TBC
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8” 3/8”
Drain Connection mm TBC TBC TBC
Internal Lift Pump TBC TBC TBC
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW TBC TBC TBC
Running Current A TBC TBC TBC
Starting Current A TBC TBC TBC
Indoor Unit £3,210 £3,552 £3,801
Spigot Kit n/a n/a n/a
Retail Price £3,210 £3,552 £3,801
Communication cable - 2 core non polar 1.5mm2 screened cable
RBC-AMT32E £50 Retail
VRF IndoorWall Mounted 3 Series
@amp_aircon | amp-air-conditioning 130
VRF
Indo
or
Indoor Unit MMK-AP0073H1 MMK-AP0093H1 MMK-AP0123H1
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 0.8 1 1.25
Nominal Cooling kW 2.2 2.8 3.6
Nominal Heating kW 2.5 3.2 4.0
PHYS
ICAL
Height mm 320 320 320
Width mm 1050 1050 1050
Depth mm 228 228 228
Weight kg 15 15 15
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 28 - 31 - 35 28 - 32 - 37 28 - 32 - 37
Airflow Rate (lo-me-hi) l/s 108 - 125 - 158 108 - 133 - 167 108 - 133 - 167
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 16 nom. 16 nom. 16 nom.
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.018 0.021 0.021
Running Current A 0.17 0.19 0.19
Starting Current A 0.22 0.24 0.24
Indoor Unit £735 £746 £757
Grille / Spigot Kit n/a n/a n/a
Retail Price £735 £746 £757
Communication cable - 2 core non polar 1.5mm2 screened cable | Unit comes with infra red controller as standard
VRF IndoorWall Mounted 3 Series
ampair.co.uk | 01707 378 670 | [email protected] 131
VRF
Indo
or
Indoor Unit MMK-AP0153H1 MMK-AP0183H1 MMK-AP0243H1
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 1.7 2 2.5
Nominal Cooling kW 4.5 5.6 7.1
Nominal Heating kW 5.0 6.3 8.0
PHYS
ICAL
Height mm 320 320 320
Width mm 1050 1050 1050
Depth mm 228 228 228
Weight kg 15 15 15
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 33 - 36 - 41 33 - 36 - 41 34 - 39 - 46
Airflow Rate (lo-me-hi) l/s 150 - 183 - 233 150 - 183 - 233 158 - 208 - 283
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2” 5/8”
Liquid Pipe Size in 1/4” 1/4” 3/8”
Drain Connection mm 16 nom. 16 nom. 16 nom.
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.043 0.043 0.050
Running Current A 0.32 0.32 0.37
Starting Current A 0.41 0.41 0.47
Indoor Unit £791 £806 £818
Grille / Spigot Kit n/a n/a n/a
Retail Price £791 £806 £818
Communication cable - 2 core non polar 1.5mm2 screened cable | Unit comes with infra red controller as standard
RBC-AMS54E-ES £105 Retail
VRF IndoorWall Mounted 4 Series
@amp_aircon | amp-air-conditioning 132
VRF
Indo
or
Indoor Unit MMK-AP0054MHP-E1 MMK-AP0074MHP-E1
Grille / Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 0.6 0.8
Nominal Cooling kW 1.7 2.2
Nominal Heating kW 1.9 2.5
PHYS
ICAL
Height mm 275 275
Width mm 790 790
Depth mm 208 208
Weight kg 11 11
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 29 - 31 - 33 29 - 32 - 35
Airflow Rate (lo-me-hi) l/s TBC 100 - 117 - 133
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4”
Drain Connection mm 16 od 16 od
Internal Lift Pump No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW TBC 0.017
Running Current A TBC 0.17
Starting Current A TBC 0.22
Indoor Unit £666 £676
Grille / Spigot Kit n/a n/a
Retail Price £666 £676
Communication cable - 2 core non polar 1.5mm2 screened cable | Unit does not come with a controller as standard | 0054 unit only compatible with SMMSe outdoor units
VRF IndoorWall Mounted 4 Series
ampair.co.uk | 01707 378 670 | [email protected] 133
VRF
Indo
or
Indoor Unit MMK-AP0094MHP-E1 MMK-AP0124MHP-E1
Grille / Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 1 1.25
Nominal Cooling kW 2.8 3.6
Nominal Heating kW 3.2 4.0
PHYS
ICAL
Height mm 275 275
Width mm 790 790
Depth mm 208 208
Weight kg 11 11
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 29 - 33 - 36 29 - 33 - 37
Airflow Rate (lo-me-hi) l/s 100 - 125 - 142 100 - 125 - 150
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4”
Drain Connection mm 16 od 16 od
Internal Lift Pump No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.018 0.019
Running Current A 0.18 0.19
Starting Current A 0.23 0.24
Indoor Unit £685 £698
Grille / Spigot Kit n/a n/a
Retail Price £685 £698
Communication cable - 2 core non polar 1.5mm2 screened cable | Unit does not come with a controller as standard
RBC-AS41E £70 Retail
VRF IndoorCeiling Suspended
@amp_aircon | amp-air-conditioning 134
VRF
Indo
or
Indoor Unit MMC-AP0157HP1-E MMC-AP0187HP1-E
Grille / Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 1.7 2
Nominal Cooling kW 4.5 5.6
Nominal Heating kW 5.0 6.3
PHYS
ICAL
Height mm 235 235
Width mm 950 950
Depth mm 690 690
Weight kg 23 23
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 28 - 34 - 36 28 - 35 - 37
Airflow Rate (lo-me-hi) l/s 150 - 200 - 233 150 - 200 - 267
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2”
Liquid Pipe Size in 1/4” 1/4”
Drain Connection mm 20 nom. 20 nom.
Internal Lift Pump No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.033 0.034
Running Current A 0.36 0.37
Starting Current A 0.54 0.55
Indoor Unit £1,119 £1,238
Grille / Spigot Kit n/a n/a
Retail Price £1,119 £1,238
Communication cable - 2 core non polar 1.5mm2 screened cable
VRF IndoorCeiling Suspended
ampair.co.uk | 01707 378 670 | [email protected] 135
VRF
Indo
or
Indoor Unit MMC-AP0247HP1-E MMC-AP0277HP1-E
Grille / Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 2.5 3
Nominal Cooling kW 7.1 8.0
Nominal Heating kW 8.0 9.0
PHYS
ICAL
Height mm 235 235
Width mm 1270 1270
Depth mm 690 690
Weight kg 29 29
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 29 - 36 - 41 29 - 36 - 41
Airflow Rate (lo-me-hi) l/s 217 - 283 - 400 217 - 283 - 400
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8”
Drain Connection mm 20 nom. 20 nom.
Internal Lift Pump No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.067 0.067
Running Current A 0.65 0.65
Starting Current A 0.97 0.97
Indoor Unit £1,311 £1,323
Grille / Spigot Kit n/a n/a
Retail Price £1,311 £1,323
Communication cable - 2 core non polar 1.5mm2 screened cable
RBC-AMS54E-ES £105 Retail
VRF IndoorCeiling Suspended
@amp_aircon | amp-air-conditioning 136
VRF
Indo
or
Indoor Unit MMC-AP0367HP1-E MMC-AP0487HP1-E MMC-AP0567HP1-E
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 4 5 6
Nominal Cooling kW 11.2 14.0 16.0
Nominal Heating kW 12.5 16.0 18.0
PHYS
ICAL
Height mm 235 235 235
Width mm 1586 1586 1586
Depth mm 690 690 690
Weight kg 35 35 35
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 32 - 38 - 44 35 - 41 - 44 36 - 42 - 46
Airflow Rate (lo-me-hi) l/s 283 - 383 - 517 333 - 433 - 514 350 - 467 - 567
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8” 3/8”
Drain Connection mm 20 nom. 20 nom. 20 nom.
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.083 0.083 0.111
Running Current A 0.77 0.77 0.99
Starting Current A 1.16 1.16 1.46
Indoor Unit £1,343 £1,366 £1,463
Grille / Spigot Kit n/a n/a n/a
Retail Price £1,343 £1,366 £1,463
Communication cable - 2 core non polar 1.5mm2 screened cable
VRF IndoorFloor Mounted Cabinet
ampair.co.uk | 01707 378 670 | [email protected] 137
VRF
Indo
or
Indoor Unit MMF-AP0156H1-E MMF-AP0186H1-E
Grille / Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 1.7 2
Nominal Cooling kW 4.5 5.6
Nominal Heating kW 5.0 6.3
PHYS
ICAL
Height mm 1750 1750
Width mm 600 600
Depth mm 210 210
Weight kg 46 46
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 37 - 42 - 46 37 - 42 - 46
Airflow Rate (lo-me-hi) l/s 183 - 217 - 250 183 - 217 - 250
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2”
Liquid Pipe Size in 1/4” 1/4”
Drain Connection mm 20 nom. 20 nom.
Internal Lift Pump No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.055 0.055
Running Current A 0.38 0.38
Starting Current A 0.53 0.53
Indoor Unit £1,313 £1,392
Grille / Spigot Kit n/a n/a
Retail Price £1,313 £1,392
Communication cable - 2 core non polar 1.5mm2 screened cable
VRF IndoorFloor Mounted Cabinet
@amp_aircon | amp-air-conditioning 138
VRF
Indo
or
Indoor Unit MMF-AP0246H1-E MMF-AP0276H1-E
Grille / Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 2.5 3
Nominal Cooling kW 7.1 8.0
Nominal Heating kW 8.0 9.0
PHYS
ICAL
Height mm 1750 1750
Width mm 600 600
Depth mm 210 210
Weight kg 47 47
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 39 - 45 - 49 39 - 45 - 49
Airflow Rate (lo-me-hi) l/s 233 - 275 - 333 233 - 275 - 333
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8”
Drain Connection mm 20 nom. 20 nom.
Internal Lift Pump No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.089 0.089
Running Current A 0.60 0.60
Starting Current A 0.84 0.84
Indoor Unit £1,453 £1,496
Grille / Spigot Kit n/a n/a
Retail Price £1,453 £1,496
Communication cable - 2 core non polar 1.5mm2 screened cable
VRF IndoorFloor Mounted Cabinet
ampair.co.uk | 01707 378 670 | [email protected] 139
VRF
Indo
or
Indoor Unit MMF-AP0366H1-E MMF-AP0486H1-E MMF-AP0566H1-E
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 4 5 6
Nominal Cooling kW 11.2 14.0 16.0
Nominal Heating kW 12.5 16.0 18.0
PHYS
ICAL
Height mm 1750 1750 1750
Width mm 600 600 600
Depth mm 390 390 390
Weight kg 62 62 62
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 41 - 46 - 51 44 - 49 - 54 44 - 49 - 54
Airflow Rate (lo-me-hi) l/s 383 - 450 - 533 433 - 481 - 600 433 - 481 - 600
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 5/8” 5/8”
Liquid Pipe Size in 3/8” 3/8” 3/8”
Drain Connection mm 20 nom. 20 nom. 20 nom.
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.135 0.160 0.160
Running Current A 0.90 1.10 1.10
Starting Current A 1.26 1.54 1.54
Indoor Unit £1,540 £1,618 £1,698
Grille / Spigot Kit n/a n/a n/a
Retail Price £1,540 £1,618 £1,698
Communication cable - 2 core non polar 1.5mm2 screened cable
VRF IndoorFloor Standing Chassis
@amp_aircon | amp-air-conditioning 140
VRF
Indo
or
Indoor Unit MML-AP0074BH1-E MML-AP0094BH1-E MML-AP0124BH1-E
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 0.8 1 1.25
Nominal Cooling kW 2.2 2.8 3.6
Nominal Heating kW 2.5 3.2 4.0
PHYS
ICAL
Height mm 600 600 600
Width mm 745 745 745
Depth mm 220 220 220
Weight kg 21 21 21
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 32 - 34 - 36 32 - 34 - 36 32 - 34 - 36
Airflow Rate (lo-me-hi) l/s 83 - 111 - 128 83 - 111 - 128 83 - 111 - 128
Static Pressure Pa 0 0 0
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 20 nom. 20 nom. 20 nom.
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.056 0.056 0.056
Running Current A 0.250 0.250 0.250
Starting Current A 0.60 0.60 0.60
Indoor Unit £769 £789 £812
Grille / Spigot Kit n/a n/a n/a
Retail Price £769 £789 £812
Communication cable - 2 core non polar 1.5mm2 screened cable | Top discharge as standard, can be converted to front discharge
VRF IndoorFloor Standing Chassis
ampair.co.uk | 01707 378 670 | [email protected] 141
VRF
Indo
or
Indoor Unit MML-AP0154BH1-E MML-AP0184BH1-E MML-AP0244BH1-E
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 1.7 2 2.5
Nominal Cooling kW 4.5 5.6 7.1
Nominal Heating kW 5.0 6.3 8.0
PHYS
ICAL
Height mm 600 600 600
Width mm 1045 1045 1045
Depth mm 220 220 220
Weight kg 29 29 29
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 32 - 34 - 36 32 - 34 - 36 33 - 37 - 42
Airflow Rate (lo-me-hi) l/s 136 - 167 - 206 136 - 167 - 206 178 - 219 - 264
Static Pressure Pa 0 0 0
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2” 5/8”
Liquid Pipe Size in 1/4” 1/4” 3/8”
Drain Connection mm 20 nom. 20 nom. 20 nom.
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.090 0.090 0.095
Running Current A 0.450 0.450 0.460
Starting Current A 0.80 0.80 1.00
Indoor Unit £848 £903 £939
Grille / Spigot Kit n/a n/a n/a
Retail Price £848 £903 £939
Communication cable - 2 core non polar 1.5mm2 screened cable | Top discharge as standard, can be converted to front discharge
RBC-AMT32E £50 Retail
VRF IndoorFloor Standing Console
@amp_aircon | amp-air-conditioning 142
VRF
Indo
or
Indoor Unit MML-AP0074H1-E MML-AP0094H1-E MML-AP0124H1-E
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 0.8 1 1.25
Nominal Cooling kW 2.2 2.8 3.6
Nominal Heating kW 2.5 3.2 4.0
PHYS
ICAL
Height mm 630 630 630
Width mm 950 950 950
Depth mm 230 230 230
Weight kg 37 37 37
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 35 - 37 - 39 35 - 37 - 39 38 - 41 - 45
Airflow Rate (lo-me-hi) l/s 100 - 117 - 133 100 - 117 - 133 181 - 217 - 250
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 20 nom. 20 nom. 20 nom.
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.056 0.056 0.092
Running Current A 0.260 0.260 0.430
Starting Current A 0.60 0.60 0.80
Indoor Unit £922 £944 £967
Grille / Spigot Kit n/a n/a n/a
Retail Price £922 £944 £967
Communication cable - 2 core non polar 1.5mm2 screened cable
VRF IndoorFloor Standing Console
ampair.co.uk | 01707 378 670 | [email protected] 143
VRF
Indo
or
Indoor Unit MML-AP0154H1-E MML-AP0184H1-E MML-AP0244H1-E
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 1.7 2 2.5
Nominal Cooling kW 4.5 5.6 7.1
Nominal Heating kW 5.0 6.3 8.0
PHYS
ICAL
Height mm 630 630 630
Width mm 950 950 950
Depth mm 230 230 230
Weight kg 37 37 37
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 38 - 41 - 45 39 - 44 - 49 39 - 44 - 49
Airflow Rate (lo-me-hi) l/s 181 - 217 - 250 217 - 258 - 300 217 - 258 - 300
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2” 5/8”
Liquid Pipe Size in 1/4” 1/4” 3/8”
Drain Connection mm 20 nom. 20 nom. 20 nom.
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.092 0.102 0.102
Running Current A 0.430 0.470 0.470
Starting Current A 0.80 1.10 1.10
Indoor Unit £1,016 £1,079 £1,126
Grille / Spigot Kit n/a n/a n/a
Retail Price £1,016 £1,079 £1,126
Communication cable - 2 core non polar 1.5mm2 screened cable
RBC-AS41E £70 Retail
VRF IndoorFloor Standing Bi Flow Console
@amp_aircon | amp-air-conditioning 144
VRF
Indo
or
Indoor Unit MML-AP0074NH1-E MML-AP0094NH1-E MML-AP0124NH1-E
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 0.8 1 1.25
Nominal Cooling kW 2.2 2.8 3.6
Nominal Heating kW 2.5 3.2 4.0
PHYS
ICAL
Height mm 600 600 600
Width mm 700 700 700
Depth mm 220 220 220
Weight kg 17 17 17
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 26 - 32 - 38 26 - 32 - 38 29 - 34 - 40
Airflow Rate (lo-me-hi) l/s 78 - 102 - 142 78 - 102 - 142 90 - 113 - 153
Static Pressure Pa n/a n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 3/8” 3/8” 3/8”
Liquid Pipe Size in 1/4” 1/4” 1/4”
Drain Connection mm 16 nom. 16 nom. 16 nom.
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.021 0.021 0.025
Running Current A 0.20 0.20 0.23
Starting Current A 0.26 0.26 0.30
Indoor Unit £960 £1,034 £1,109
Grille / Spigot Kit n/a n/a n/a
Retail Price £960 £1,034 £1,109
Communication cable - 2 core non polar 1.5mm2 screened cable
VRF IndoorFloor Standing Bi Flow Console
ampair.co.uk | 01707 378 670 | [email protected] 145
VRF
Indo
or
Indoor Unit MML-AP0154NH1-E MML-AP0184NH1-E
Grille / Spigot Kit n/a n/a
PERF
ORM
ANCE Capacity Code 1.7 2
Nominal Cooling kW 4.5 5.6
Nominal Heating kW 5.0 6.3
PHYS
ICAL
Height mm 600 600
Width mm 700 700
Depth mm 220 220
Weight kg 17 17
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-me-hi) dB(A) 31 - 37 - 43 34 - 40 - 47
Airflow Rate (lo-me-hi) l/s 107 - 130 - 173 118 - 147 - 202
Static Pressure Pa n/a n/a
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 1/2” 1/2”
Liquid Pipe Size in 1/4” 1/4”
Drain Connection mm 16 nom. 16 nom.
Internal Lift Pump No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3
Power Input kW 0.034 0.052
Running Current A 0.29 0.42
Starting Current A 0.38 0.55
Indoor Unit £1,183 £1,227
Grille / Spigot Kit n/a n/a
Retail Price £1,183 £1,227
Communication cable - 2 core non polar 1.5mm2 screened cable
BMS-SM1280ETLE Smart Manager £2,000 Retail
VRF
Indo
or
AMP Air ConditioningField Based Staff
146@amp_aircon | amp-air-conditioning
In addition to our offices in Welwyn Garden City and Bristol we have an extensive network of sales and technical support staff covering the UK.
All our field based team have an in-depth knowledge of our product ranges. They are supported by our central sales department so there is always someone availiable to help with your enquiry. We are committed to helping you select the most suitable system for your needs and budget to ensure that you receive comprehensive project support.
Our field based team can supportyou throughout the whole project process, including
» On site surveys» Extensive product knowledge» Design advice and unit selections / quotations» Pipe work and wiring schematics» Product documentation including O&M manuals» Advice on integrating our units with the latest control systems» Project support from conception to handover
Our team is further enhanced by experienced and highly qualified field based engineers. With access to state of the art diagnostics tools, they are able to provide you with techni-cal support whenever needed.
For further details or to arrange a meeting with your local team member please contact us on 01707 378 670 or email [email protected]
Air Handling & HRV
AHU
& H
RV
ampair.co.uk | 01707 378 670 | [email protected] 147ampair.co.uk | 01707 378 670 | [email protected] 147
@amp_aircon | amp-air-conditioning 148
AHU
& H
RV
Air Handling & HRVAir to Air Heat Exchangers with DX Coil
Indoor Unit MMD-VN502HEX1E MMD-VN802HEX1E MMD-VN1002HEX1E
Remote Controller NRC-01HE NRC-01HE NRC-01HE
Capacity Code 1.0 1.7 2.0
Fresh Air Conditioning Load (cooling) kW 4.10 (1.30) 6.56 (2.06) 8.25 (2.32)Fresh Air Conditioning Load (heating) kW 5.53 (2.33) 8.61 (3.61) 10.92 (4.32)
Air Volume (extra high) m3/h - l/s 500 - 139 800 - 222 950 - 264Air Volume (low) m3/h - l/s 440 - 122 640 - 178 820 - 278Airflow Limit (upper) m3/h - l/s 600 - 167 960 - 267 1140 - 317Airflow Limit (lower) m3/h - l/s 330 - 92 480 - 133 640 - 178
Unit (height-width-depth) mm 430 - 1140 - 1690 430 - 1189 - 1739 430 - 1189 - 1739Weight kg 84 100 101
Duct Diameter mm 200 250 250External Static Pressure - extra high Pa 120 120 135External Static Pressure - high Pa 105 100 120External Static Pressure - low Pa 115 100 105
Temperature Exchange Efficiency (H-L) % 70.5 - 71.5 70.0 - 72.5 65.5 - 67.5Enthalpy Exchange Efficiency cool (H-L) % 56.5 - 57.5 56.0 - 59.0 52.0 - 54.0Enthalpy Exchange Efficiency heat (H-L) % 68.5 - 69.0 70.0 - 73.0 66.0 - 68.5
Sound Pressure Level - Extra High dB(A) 37.5 41.0 43.0Sound Pressure Level - High dB(A) 36.5 40.0 42.0Sound Pressure Level - Low dB(A) 34.5 38.0 40.0
Pipe Sizes (gas - liquid) in 3/8” - 1/4” 1/2” - 1/4” 1/2” - 1/4”Indoor Drain Connection mm 25 25 25
Water Pressure Mpa n/a n/a n/aWater Flow kg/h n/a n/a n/aWater Supply in n/a n/a n/a
Power Supply (V - Ph - Hz) 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Power Consumption (eh - h - l) W 300 - 280 - 235 505 - 465 - 335 550 - 545 - 485Running Current (eh - h - l) A 1.30 - 1.21 - 1.01 2.25 - 2.07 - 1.46 2.46 - 2.43 - 2.16Suggested Fuse Size A 3 3 3
Operating Range - around unit -10°C to 40°C 80% RH or lessOperating Range - outdoor air -15°C to 43°C 80% RH or less
Operating Range - return air 5°C to 40°C 80% RH or less
VN Unit £3,193 £4,654 £5,315
Remote Controller £74 £74 £74
Retail Price £3,267 £4,728 £5,389
Cooling and heating capacities are based upon the following conditions
Cooling: 27°CDB 19°CWB indoor, 35°CDB outdoor, the figures in ( ) indicate the heat reclaimed from the heat recovery ventilatorHeating: 20°CDB indoor, 7°CDB 6°CWB outdoor, the figures in ( ) indicate the heat reclaimed from the heat recovery ventilator
ampair.co.uk | 01707 378 670 | [email protected] 149
AHU
& H
RV
Air Handling & HRVAir to Air Heat Exchangers with DX Coil & Humidifier
Indoor Unit MMD-VNK502HEX1E MMD-VNK802HEX1E MMD-VNK1002HEX1E
Remote Controller NRC-01HE NRC-01HE NRC-01HE
Capacity Code 1.0 1.7 2.0
Fresh Air Conditioning Load (cooling) kW 4.10 (1.30) 6.56 (2.06) 8.25 (2.32)Fresh Air Conditioning Load (heating) kW 5.53 (2.33) 8.61 (3.61) 10.92 (4.32)
Air Volume (extra high) m3/h - l/s 500 - 139 800 - 222 950 - 264Air Volume (low) m3/h - l/s 440 - 122 640 - 178 820 - 228Airflow Limit (upper) m3/h - l/s 600 - 167 960 - 267 1140 - 317Airflow Limit (lower) m3/h - l/s 330 - 92 480 - 133 640 - 178
Unit (height-width-depth) mm 430 - 1140 - 1690 430 - 1189 - 1739 430 - 1189 - 1739Weight kg 91 111 112
Duct Diameter mm 200 250 250External Static Pressure - extra high Pa 95 105 110External Static Pressure - high Pa 85 85 90External Static Pressure - low Pa 95 90 115
Temperature Exchange Efficiency (H-L) % 70.5 - 71.5 70.0 - 72.5 65.5 - 67.5Enthalpy Exchange Efficiency cool. (H-L) % 56.5 - 57.5 56.0 - 59.0 52.0 - 54.0Enthalpy Exchange Efficiency heat. (H-L) % 68.5 - 69.0 70.0 - 73.0 66.0 - 68.5
Sound Pressure Level - Extra High dB(A) 36.5 40.0 42.0Sound Pressure Level - High dB(A) 35.5 39.0 41.0Sound Pressure Level - Low dB(A) 33.5 38.0 39.0
Pipe Sizes (gas - liquid) in 3/8” - 1/4” 1/2” - 1/4” 1/2” - 1/4”Indoor Drain Connection mm 25 25 25
Water Pressure Mpa 0.02 - 0.49 0.02 - 0.49 0.02 - 0.49Water Flow kg/h 3 5 6Water Supply in 1/2” 1/2” 1/2”
Power Supply (V - Ph - Hz) 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Power Consumption (eh - h - l) W 305 - 285 - 240 530 - 485 - 350 575 - 565 - 520Running Current (eh - h - l) A 1.33 - 1.24 - 1.03 2.37 - 2.14 - 1.54 2.56 - 2.51 - 2.31Suggested Fuse Size A 3 3 5
Operating Range - around unit -10°C to 40°C 80% RH or lessOperating Range - outdoor air -15°C to 43°C 80% RH or less
Operating Range - return air 5°C to 40°C 80% RH or less
VN Unit £3,605 £5,247 £6,000
Remote Controller £74 £74 £74
Retail Price £3,679 £5,321 £6,074
Cooling and heating capacities are based upon the following conditions
Cooling: 27°CDB 19°CWB indoor, 35°CDB outdoor, the figures in ( ) indicate the heat reclaimed from the heat recovery ventilator
Heating: 20°CDB indoor, 7°CDB 6°CWB outdoor, the figures in ( ) indicate the heat reclaimed from the heat recovery ventilator
Humidification available during heating operation
The water quality of the humidifiers supply water should meet public waterworks standards and have a hardness of less than 100mg/l
If the water does not meet the above standard then you must use a deionizer.
@amp_aircon | amp-air-conditioning 150
AHU
& H
RV
Air Handling & HRVFresh Air Intake Units
Indoor Unit MMD-AP0481HFE MMD-AP0721HFE MMD-AP0961HFE
Grille / Spigot Kit n/a n/a n/a
PERF
ORM
ANCE Capacity Code 5 8 10
Nominal Cooling kW 14.0 22.4 28.0
Nominal Heating kW 8.9 13.9 17.4
PHYS
ICAL
Height mm 492 492 492
Width mm 892 1392 1392
Depth mm 1262 1262 1262
Weight kg 93 144 144
SOU
ND
&
AIRF
LOW
Sound Pressure Level (lo-hi) dB(A) 41 - 45 44 - 46 44 - 46
Airflow Rate (high) l/s 300 466 466
Static Pressure (lo-me-hi) Pa 170 - 210 - 230 140 - 165 - 180 160 - 190 - 205
REFR
IGER
ANT
&
PIPE
WO
RK
Gas Pipe Size in 5/8” 7/8” 7/8”
Liquid Pipe Size in 3/8” 1/2” 1/2”
Drain Connection mm TBC TBC TBC
Internal Lift Pump No No No
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 3 3 3
Power Input kW 0.280 0.450 0.520
Running Current A 1.43 2.52 2.73
Starting Current A 3.50 7.00 7.00
Indoor Unit £1,854 £3,070 £3,243
Grille / Spigot Kit n/a n/a n/a
Retail Price £1,854 £3,070 £3,243
Accessory Model Part Number Retail Price100% Fresh air units
Allows air to be pre-heated or pre-cooled
Only compatible with SMMSe
Not suitable for SHRMi or Mini SMMS systems
Air must be pre-filtered
Total indoor unit + fresh air capacity must be 80 to 100% of outdoor unit capacity
Fresh air units can make up no more than 30% of total indoor capacity code
* The filter box can accommodate 2 filters - one of which must be a pre-filter. Either but not both high efficiency filters may also be used in conjunction with the pre-filter
Drain Pump Option
MMD-AP0481HFE TCB-DP31DE £809
MMD-AP0721HFETCB-DP32DE £809
MMD-AP0961HFE
Filter Box Option *
MMD-AP0481HFE TCB-FCY51DE £331
MMD-AP0721HFETCB-FCY100DE £614
MMD-AP0961HFE
Pre Filter Option
MMD-AP0481HFE TCB-PF1D-1E (2 REQ.) £46 Each
MMD-AP0721HFETCB-PF3DE £158
MMD-AP0961HFE
65% Filter Option
MMD-AP0481HFE TCB-UFM1D-1E (2 REQ.) £147 Each
MMD-AP0721HFETCB-UFM3DE £488
MMD-AP0961HFE
90% Filter Option
MMD-AP0481HFE TCB-UFH5D-1E (2 REQ.) £152 Each
MMD-AP0721HFETCB-UFH7DE £504
MMD-AP0961HFE
ampair.co.uk | 01707 378 670 | [email protected] 151
AHU
& H
RV
Air Handling & HRVHeat Recovery Ventilation Units
VN Unit VN-M150HE VN-M250HE VN-M350HE
Remote Controller NRC-01HE NRC-01HE NRC-01HE
Air Volume (high) m3/h - l/s 150 - 42 250 - 69 350 - 97
Air Volume (low) m3/h - l/s 110 - 31 155 - 43 210 - 58
Unit (height-width-depth) mm 290 x 900 x 900 290 x 900 x 900 290 x 900 x 900
Weight kg 36 36 38
Duct Diameter mm 100 150 150
External Static Pressure - extra high Pa 82 - 102 80 - 98 114 - 125
External Static Pressure - high Pa 52 - 78 34 - 65 56 - 83
External Static Pressure - low Pa 47 - 64 28 - 40 65 - 94
Filtration Efficiency Grade 82% 82% 82%
Temperature Exchange Efficiency (H-L) % 81.5 - 83.0 87.0 - 81.5 74.5 - 79.5
Sound Pressure Level - Extra High dB(A) 26.0 - 28.0 29.5 - 30.0 34.0 - 35.0
Sound Pressure Level - High dB(A) 24.0 - 25.5 25.0 - 27.0 30.0 - 32.0
Sound Pressure Level - Low dB(A) 20.0 - 22.0 21.0 - 22.0 27.0 - 29.0
Power Supply (V - Ph - Hz) 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Power Consumption - Extra High W 68 - 78 123 - 138 165 - 182
Power Consumption - High W 59 - 67 99 - 111 135 - 145
Power Consumption - Low W 42 - 47 52 - 59 82 - 88
Operating Range - around unit -10°C to 40°C 80% RH or less
Operating Range - outdoor air -15°C to 43°C 80% RH or less
Operating Range - return air 5°C to 40°C 80% RH or less
VN Unit £1,004 £1,033 £1,187
Remote Controller £74 £74 £74
Retail Price £1,078 £1,107 £1,261
Dimensions do not include electrical box 200mm
Accessory RBC-VNL1 RBC-VNMH1-PE RBC-VNMH2-PE RBC-VNMC-PE
Description VN unit wiring interface for remote on-off
100mm heater kit forVN-M150
150mm heater kit forVN-M250-350 Heater Kit Controller
Retail Price £50 £360 £360 £407
@amp_aircon | amp-air-conditioning 152
AHU
& H
RV
Air Handling & HRVHeat Recovery Ventilation Units
VN Unit VN-M500HE VN-M650HE VN-M800HE
Remote Controller NRC-01HE NRC-01HE NRC-01HE
Air Volume (high) m3/h - l/s 500 - 139 650 - 180 800 - 222
Air Volume (low) m3/h - l/s 390 - 108 520 - 144 700 - 194
Unit (height-width-depth) mm 350 x 1140 x 1140 350 x 1140 x 1140 400 x 1189 x 1189
Weight kg 53 53 70
Duct Diameter mm 200 200 250
External Static Pressure - extra high Pa 134 - 150 91 - 107 142 - 158
External Static Pressure - high Pa 69 - 99 58 - 82 102 - 132
External Static Pressure - low Pa 62 - 92 61 - 96 76 - 112
Filtration Efficiency Grade 82% 82% 82%
Temperature Exchange Efficiency (H-L) % 76.5 - 78.0 75.0 - 76.5 76.5 - 77.5
Sound Pressure Level - Extra High dB(A) 32.5 - 34.0 34.0 - 36.0 37.0 - 38.5
Sound Pressure Level - High dB(A) 29.5 - 31.0 33.0 - 34.0 35.5 - 37.0
Sound Pressure Level - Low dB(A) 26.0 - 29.0 31.0 - 32.5 33.5 - 35.0
Power Supply (V - Ph - Hz) 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Power Consumption - Extra High W 214 - 238 262 - 290 360 - 383
Power Consumption - High W 176 - 192 240 - 258 339 - 353
Power Consumption - Low W 128 - 142 178 - 191 286 - 300
Operating Range - around unit -10°C to 40°C 80% RH or less
Operating Range - outdoor air -15°C to 43°C 80% RH or less
Operating Range - return air 5°C to 40°C 80% RH or less
VN Unit £1,437 £1,597 £1,870
Remote Controller £74 £74 £74
Retail Price £1,511 £1,671 £1,944
Dimensions do not include electrical box 200mm
Accessory RBC-VNL1 RBC-VNMH3-PE RBC-VNMH4-PE RBC-VNMC-PE
Description VN unit wiring interface for remote on-off
200mm heater kit forVN-M500-650
250mm heater kit forVN-M800-1000 Heater Kit Controller
Retail Price £50 £417 £417 £407
ampair.co.uk | 01707 378 670 | [email protected] 153
AHU
& H
RV
Air Handling & HRVHeat Recovery Ventilation Units
VN Unit VN-M1000HE VN-M1500HE VN-M2000HE
Remote Controller NRC-01HE NRC-01HE NRC-01HE
Air Volume (high) m3/h - l/s 1000 - 278 1500 - 417 2000 - 556
Air Volume (low) m3/h - l/s 755 - 210 1200 - 333 1400 - 389
Unit (height-width-depth) mm 400 x 1189 x 1189 810 x 1189 x 1189 810 x 1189 x 1189
Weight kg 70 143 143
Duct Diameter mm 250 250 250
External Static Pressure - extra high Pa 130 - 150 135 - 156 124 - 143
External Static Pressure - high Pa 97 - 122 103 - 129 92 - 116
External Static Pressure - low Pa 84 - 127 112 - 142 110 - 143
Filtration Efficiency Grade 82% 82% 82%
Temperature Exchange Efficiency (H-L) % 73.5 - 77.0 76.5 - 79.0 73.5 - 77.5
Sound Pressure Level - Extra High dB(A) 39.5 - 40.5 38.0 - 39.0 41.0 - 42.5
Sound Pressure Level - High dB(A) 38.5 - 40.0 36.5 - 37.5 39.5 - 41.0
Sound Pressure Level - Low dB(A) 34.0 - 35.5 36.0 - 37.5 37.0 - 38.0
Power Supply (V - Ph - Hz) 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Power Consumption - Extra High W 532 - 569 751 - 786 1084 - 1154
Power Consumption - High W 494 - 538 708 - 784 1032 - 1080
Power Consumption - Low W 353 - 370 570 - 607 702 - 742
Operating Range - around unit -10°C to 40°C 80% RH or less
Operating Range - outdoor air -15°C to 43°C 80% RH or less
Operating Range - return air 5°C to 40°C 80% RH or less
VN Unit £2,076 £3,942 £4,331
Remote Controller £74 £74 £74
Retail Price £2,150 £4,016 £4,405
Dimensions do not include electrical box 200mm
Accessory RBC-VNL1
Description VN unit wiring interface for remote on-off
Retail Price £50
@amp_aircon | amp-air-conditioning 154
AHU
& H
RV
Air Handling & HRVVRF Air Handling Unit Interface
DX Controller Model MM-DXC010 MM-DXC010 MM-DXC010 MM-DXC010
DX Valve Kit Model MM-DXV080 MM-DXV080 MM-DXV080 MM-DXV140
Capacity Code 2 2.5 3 4Nominal Cooling Capacity kW 5.6 7.1 8.0 11.2Nominal Heating Capacity kW 6.3 8.0 9.0 12.5
Controller unit height mm 400 400 400 400Controller unit width mm 300 300 300 300Controller unit depth mm 150 150 150 150Controller unit weight mm 8 8 8 8
Hex Air Volume m3/hr 720 - 1080 1060 - 1580 1060 - 1580 1280 - 1920Hex Coil Volume cm3 800 - 1100 1000 - 1400 1000 - 1400 1500 - 2100Hex Coil Diameter in 3/8” 3/8” 3/8” 3/8”Hex Paths 4 - 6 6 - 8 6 - 8 6 - 10
Evaporating Temperature Range °C 6.5 6.5 6.5 6.5Suction Superheat K 5 5 5 5Condensing Temperature °C 52 52 52 52
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Suggested Fuse Size A 6 6 6 6
DX Controller £583 £583 £583 £583
DX Valve Kit £338 £338 £338 £338
Retail Price £921 £921 £921 £921
For Multi-Circuit DX coil; applications outdoor units can be combined up to 48HP by the inclusion of the DXC012 follower panel(s) £440 each, contact AMP for details
Allows connection of a 3rd party AHU unit to all Toshiba VRF products using a locally supplied DX coil
Control is achieved using a standard Toshiba remote controller (RBC-AMT32E)
Compatible with Toshiba control accessories
External on/off input
Safety cut out input to detect fan failure
Multi-Circuitcombinationsalso available.
Contact AMP for more
information.
ampair.co.uk | 01707 378 670 | [email protected] 155
AHU
& H
RV
Air Handling & HRVVRF Air Handling Unit Interface
DX Controller Model MM-DXC010 MM-DXC010 MM-DXC010 MM-DXC010
DX Valve Kit Model MM-DXV140 MM-DXV140 MM-DXV280 MM-DXV280
Capacity Code 5 6 8 10Nominal Cooling Capacity kW 14.0 16.0 22.4 28.0Nominal Heating Capacity kW 16.0 18.0 25.0 31.5
Controller unit height mm 400 400 400 400Controller unit width mm 300 300 300 300Controller unit depth mm 150 150 150 150Controller unit weight mm 8 8 8 8
Hex Air Volume m3/hr 1680 - 2520 1850 - 3740 2880 - 4320 3360 - 5040Hex Coil Volume cm3 1700 - 2700 1700 - 3200 3000 - 4200 3000 - 5400Hex Coil Diameter in 3/8” 3/8” 3/8” 3/8”Hex Paths 8 - 12 8 - 12 10 - 12 10 - 12
Evaporating Temperature Range °C 6.5 6.5 6.5 6.5Suction Superheat K 5 5 5 5Condensing Temperature °C 52 52 52 52
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Suggested Fuse Size A 6 6 6 6
DX Controller £583 £583 £583 £583
DX Valve Kit £338 £338 £338 £338
Retail Price £921 £921 £921 £921
For Multi-Circuit DX coil; applications outdoor units can be combined up to 48HP by the inclusion of the DXC012 follower panel(s) £440 each, contact AMP for details
Allows connection of a 3rd party AHU unit to all Toshiba VRF products using a locally supplied DX coil
Control is achieved using a standard Toshiba remote controller (RBC-AMT32E)
Compatible with Toshiba control accessories
External on/off input
Safety cut out input to detect fan failure
@amp_aircon | amp-air-conditioning 156
AHU
& H
RV
Air Handling & HRVAir Handling Unit Interface for Digital Inverters
Outdoor Unit RAV-SM304ATP-E RAV-SM404ATP-E RAV-SM564ATP-E
AHU Interface RBC-AHU1 RBC-AHU1 RBC-AHU1
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E
PERF
ORM Cooling Capacity Range kW 0.9 - 3.0 0.9 - 4.0 1.5 - 5.6
Heating Capacity Range kW 0.8 - 4.5 0.8 - 5.0 1.5 - 6.3
PHYS
ICAL
Outdoor Unit - Height mm 550 550 550Outdoor Unit - Width mm 780 780 780Outdoor Unit - Depth mm 290 290 290Outdoor Unit - Weight mm 33 39 40
OU
Outdoor Unit Air Flow l/s 500 616 667OU Sound Pressure Level Cool - Heat dB(A) 46 - 47 49 - 50 46 - 48
HEA
T EX
CHAN
GER Hex Air Volume m3/hr 480 - 660 522 - 690 480 - 1100
Hex Coil Volume cm3 TBC TBC 500 - 1500Hex Coil Diameter in 3/8” 3/8” 3/8”Hex Paths 4 4 - 6 4 - 6
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 3/8” - 1/4” 1/2” - 1/4” 1/2” - 1/4”Pipe Limits (min - max) m 2 - 20 2 - 20 5 - 30Pre-charged for m 15 15 20Charge R410A (Factory - Additional) kg 0.8 - 20g/m 1.4 - 20g/m 1.1 - 20g/mSuitable for Replacement Tech. Yes Yes Yes
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Running Current A 3.86 5.14 8.95
Suggested Fuse Size A 10 10 16
Outdoor Unit £588 £704 £840
AHU Interface £461 £461 £461
Remote Controller £66 £66 £66
Retail Price £1,115 £1,231 £1,367Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)
ampair.co.uk | 01707 378 670 | [email protected] 157
AHU
& H
RV
Air Handling & HRVAir Handling Unit Interface for Digital Inverters
Outdoor Unit RAV-SM804ATP-E RAV-SM1104ATP-E RAV-SM1404ATP-E
AHU Interface RBC-AHU1 RBC-AHU1 RBC-AHU1
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E
PERF
ORM Cooling Capacity Range kW 1.5 - 8.0 3.0 - 11.2 3.0 - 13.2
Heating Capacity Range kW 1.5 - 9.0 3.0 - 13.0 3.0 - 16.0
PHYS
ICAL
Outdoor Unit - Height mm 550 890 890Outdoor Unit - Width mm 780 900 900Outdoor Unit - Depth mm 290 320 320Outdoor Unit - Weight mm 44 68 68
OU
Outdoor Unit Air Flow l/s 750 1133 1166OU Sound Pressure Level Cool - Heat dB(A) 48 - 52 53 - 54 54 - 55
HEA
T EX
CHAN
GER Hex Air Volume m3/hr 700 - 1500 1260 - 2500 1260 - 2750
Hex Coil Volume cm3 800 - 2400 1000 - 3000 1250 - 3750Hex Coil Diameter in 3/8” 3/8” 3/8”Hex Paths 6 - 8 6 - 10 8 - 12
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 30 5 - 30 5 - 50Pre-charged for m 20 30 30Charge R410A (Factory - Additional) kg 1.7 - 40g/m 2.8 - 40g/m 2.8 - 40g/mSuitable for Replacement Tech. Yes Yes Yes
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Running Current A 11.43 15.18 21.37
Suggested Fuse Size A 16 20 32
Outdoor Unit £1,177 £1,549 £1,633
AHU Interface £461 £461 £461
Remote Controller £66 £66 £66
Retail Price £1,704 £2,076 £2,160Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)
@amp_aircon | amp-air-conditioning 158
AHU
& H
RV
Air Handling & HRVAir Handling Unit Interface for Digital Inverters
Outdoor Unit RAV-SM1603AT-E RAV-SM2244AT8-E RAV-SM2804T8-E
AHU Interface RBC-AHU1 RBC-AHU1 RBC-AHU1
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E
PERF
ORM Cooling Capacity Range kW 3.0 - 16.0 9.8 - 22.4 9.8 - 27.0
Heating Capacity Range kW 3.0 - 16.0 9.8 - 25.0 9.8 - 31.5
PHYS
ICAL
Outdoor Unit - Height mm 1340 1540 1540Outdoor Unit - Width mm 900 900 900Outdoor Unit - Depth mm 320 320 320Outdoor Unit - Weight mm 99 134 134
OU
Outdoor Unit Air Flow l/s 1717 2217 2217OU Sound Pressure Level Cool - Heat dB(A) 51 - 53 56 - 57 57 - 58
HEA
T EX
CHAN
GER Hex Air Volume m3/hr 1260 - 3000 2880 - 4320 3360 - 5040
Hex Coil Volume cm3 1400 - 4200 2000 - 6000 2500 - 7500Hex Coil Diameter in 3/8” 3/8” 3/8”Hex Paths 8 - 12 10 - 12 10 - 12
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 1 1/8” - 1/2” 1 1/8” - 1/2”Pipe Limits (min - max) m 5 - 50 5 - 75 5 - 75Pre-charged for m 30 30 30Charge R410A (Factory - Additional) kg 3.1 - 40g/m 5.9 - 80g/m 5.9 - 80g/mSuitable for Replacement Tech. Yes Yes Yes
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50Running Current A 21.70 13.33 per phase 15.83 per phase
Suggested Fuse Size A 32 16 per phase 20 per phase
Outdoor Unit £2,059 £3,000 £3,095
AHU Interface £461 £461 £461
Remote Controller £66 £66 £66
Retail Price £2,586 £3,527 £3,622Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)
ampair.co.uk | 01707 378 670 | [email protected] 159
AHU
& H
RV
Air Handling & HRVAir Handling Unit Interface for Super Digital Inverters
Outdoor Unit RAV-SP404AT-E RAV-SP564ATP-E RAV-SP804ATP-E
AHU Interface RBC-AHU1 RBC-AHU1 RBC-AHU1
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E
PERF
ORM Cooling Capacity Range kW 1.5 - 4.0 1.2 - 5.6 1.9 - 8.0
Heating Capacity Range kW 1.5 - 5.0 0.9 - 8.1 1.3 - 11.3
PHYS
ICAL
Outdoor Unit - Height mm 550 550 890Outdoor Unit - Width mm 780 780 900Outdoor Unit - Depth mm 290 290 320Outdoor Unit - Weight mm 40 44 66
OU
Outdoor Unit Air Flow l/s 667 667 833OU Sound Pressure Level Cool - Heat dB(A) 45 - 47 47 - 48 48 - 49
HEA
T EX
CHAN
GER Hex Air Volume m3/hr 480 - 880 480 - 1100 700 - 1500
Hex Coil Volume cm3 350 - 1050 500 - 1500 800 - 2400Hex Coil Diameter in 3/8” 3/8” 3/8”Hex Paths 4 4 - 6 6 - 8
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 1/2” - 1/4” 1/2” - 1/4” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 50 5 - 50 5 - 50Pre-charged for m 20 20 30Charge R410A (Factory - Additional) kg 1.0 - 20g/m 1.4 - 20g/m 2.1 - 40g/mSuitable for Replacement Tech. Yes Yes Yes
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Running Current A 4.98 6.55 9.02
Suggested Fuse Size A 10 16 16
Outdoor Unit £998 £1,097 £1,628
AHU Interface £461 £461 £461
Remote Controller £66 £66 £66
Retail Price £1,525 £1,624 £2,155Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)
@amp_aircon | amp-air-conditioning 160
AHU
& H
RV
Air Handling & HRVAir Handling Unit Interface for Super Digital Inverters
Outdoor Unit RAV-SP1104AT-E RAV-SP1104AT8-E
AHU Interface RBC-AHU1 RBC-AHU1
Remote Controller RBC-AMS41E RBC-AMS41E
PERF
ORM Cooling Capacity Range kW 2.6 - 12.0 2.6 - 12.0
Heating Capacity Range kW 2.4 - 13.0 2.4 - 13.0
PHYS
ICAL
Outdoor Unit - Height mm 1340 1340Outdoor Unit - Width mm 900 900Outdoor Unit - Depth mm 320 320Outdoor Unit - Weight mm 93 93
OU
Outdoor Unit Air Flow l/s 1683 1683OU Sound Pressure Level Cool - Heat dB(A) 49 - 50 49 - 50
HEA
T EX
CHAN
GER Hex Air Volume m3/hr 1260 - 2500 1260 - 2500
Hex Coil Volume cm3 1000 - 3000 1000 - 3000Hex Coil Diameter in 3/8” 3/8”Hex Paths 6 - 10 6 - 10
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 3 - 75 3 - 75Pre-charged for m 30 30Charge R410A (Factory - Additional) kg 3.1 - 40g/m 3.1 - 40g/mSuitable for Replacement Tech. Yes Yes
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50Running Current A 10.43 3.72 per phase
Suggested Fuse Size A 16 10 per phase
Outdoor Unit £1,995 £2,184
AHU Interface £461 £461
Remote Controller £66 £66
Retail Price £2,522 £2,711Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)
ampair.co.uk | 01707 378 670 | [email protected] 161
AHU
& H
RV
Air Handling & HRVAir Handling Unit Interface for Super Digital Inverters
Outdoor Unit RAV-SP1404AT-E RAV-SP1404AT8-E RAV-SP1604AT8-E
AHU Interface RBC-AHU1 RBC-AHU1 RBC-AHU1
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E
PERF
ORM Cooling Capacity Range kW 2.6 - 14.0 2.6 - 14.0 2.6 - 16.0
Heating Capacity Range kW 2.4 - 16.5 2.4 - 16.5 2.4 - 19.0
PHYS
ICAL
Outdoor Unit - Height mm 1340 1340 1340Outdoor Unit - Width mm 900 900 900Outdoor Unit - Depth mm 320 320 320Outdoor Unit - Weight mm 95 95 95
OU
Outdoor Unit Air Flow l/s 1717 1717 1717OU Sound Pressure Level Cool - Heat dB(A) 51 - 52 51 - 52 51 - 53
HEA
T EX
CHAN
GER Hex Air Volume m3/hr 1260 - 2750 1260 - 2750 1260 - 3000
Hex Coil Volume cm3 1250 - 3750 1250 - 3750 1400 - 4200Hex Coil Diameter in 3/8” 3/8” 3/8”Hex Paths 8 - 12 8 - 12 8 - 12
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 3 - 75 3 - 75 3 - 75Pre-charged for m 30 30 30Charge R410A (Factory - Additional) kg 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/mSuitable for Replacement Tech. Yes Yes Yes
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50Running Current A 15.76 5.42 per phase 6.66 per phase
Suggested Fuse Size A 25 16 per phase 16 per phase
Outdoor Unit £2,205 £2,279 £2,426
AHU Interface £461 £461 £461
Remote Controller £66 £66 £66
Retail Price £2,732 £2,806 £2,953Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)
“It’s always a pleasure to do business with AMP - they provide a great level of personal customer service and are
always willing to go the extra mile.”Tim Church -
Calibre Climate Control
Photo: Sarah Smith, Internal Sales Administrator at AMP
AHU
& H
RV
@amp_aircon | amp-air-conditioning 162
Applied & Air to Water
Appl
ied
& A
2W
ampair.co.uk | 01707 378 670 | [email protected] 163ampair.co.uk | 01707 378 670 | [email protected] 163
CIAT installation at Queen Mary University courtesy of Hawkes Refrigeration
@amp_aircon | amp-air-conditioning 164
Appl
ied
& A
2W
Applied Products & Air to WaterCIAT Products
AMP have been recognised as a Toshiba Platinum Partner. As such AMP can now offer the complete range of CIAT products to the UK market. CIAT supplies an extensive range of high performance chillers, air handling units, fan coils and heat pumps.
CIAT Chillers and heat pumps are designed and manufactured at their European sites in ultra-modern industrial plants, thereby benefiting from all the group’s industrial resources.
With over 80 years experience, more than 2,000 employees and 6 production sites, CIAT has obtained ISO 14001 certification and is renowned as a major player in the HVAC industry.
Aquaciat Power, Air to Water 190 - 657kW
The complete CIAT range includes» Air to water heat pumps and water chillers» Water to water heat pumps and water chillers» Fan coil units» Air handling units» Roof top packaged units» Dry coolers» Thermal energy storage
Major Line Cased Unit - 0.7 - 11.0kW
CIAT’s UK operation has moved to new headquarters alongside Toshiba in Leatherhead. This new CIAT base will include a dedicated air conditioning training centre with working equipment, a show room and administration offices for technical support and sales staff.
Equipment will be stocked and distributed from Toshiba’s UK logistics hub at Plymouth. ClimaCIAT Airtop Air Handling Unit up to 17,000m3/h
ampair.co.uk | 01707 378 670 | [email protected] 165
Appl
ied
& A
2W
Applied Products & Air to WaterCIAT Products
The packaged air-cooled CIAT chiller, with a capacity of 141kW of cooling, is equipped with optional inverter-controlled variable speed pumps for improved efficiency, delivering an EER of 3.09 and SEER of 4.06.
The R410A-based system running on scroll compressors is designed to allow for future expansion as part of a staged replacement process. This includes the use of 6in diameter chilled water pipework and a 10in low-loss header to permit the addition of up to three further Toshiba/CIAT chillers, one of which would be on standby.
The first CIAT chiller to be supplied by Toshiba distributor AMP Air has been installed at Queen Mary University of London.
The AquaCIAT 2 Evolution chiller was installed by Basildon-based Hawkes Refrigeration Engineers at the John Vane Science Centre, the world-renowned cancer research centre on the University’s Charterhouse campus.The installation was part of a major replacement and upgrade of the building’s air conditioning system.
CIAT chiller installation at Queen Mary UniversityCourtesy of Hawkes Refrigeration
It had previously relied on an ageing split system, using a water chiller linked to remote condensing units.
Given the sensitive research environment, the chiller is equipped with enhanced acoustic insulation in order to minimise noise in the vicinity of the installation.
For further details please contact us on01707 378 670 or email [email protected]
@amp_aircon | amp-air-conditioning 166
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Free Hanging - Digital Inverter
Air Curtain RAV-CT101CH-M RAV-CT101CH-L RAV-CT151CH-M RAV-CT151CH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM804ATP-E RAV-SM804ATP-E RAV-SM1104ATP-ERAV-SM1104ATP-E
PERF
ORM
ANCE Horse Power 3 3 4 4
Heating Capacity kW 8.0 8.0 11.2 11.2Heating COP 2.46 2.52 2.44 2.65
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1000 1000 1500 1500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 1210 - 490 260 - 1210 - 490 260 - 1710 - 490 260 - 1710 - 490Weight kg 54 57 85 87Standard Airflow l/s 422 583 633 778Sound Pressure Level dB(A) 54 55 55 56
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 550 - 780 - 290 550 - 780 - 290 890 - 900 - 320 890 - 900 - 320Weight kg 44 44 68 68Operating Range (Cooling - Heating) 46°C to -15°C / 15°C to -15°CStandard Airflow l/s 750 750 1133 1133Sound Pressure Level (Cooling - Heating) dB(A) 48 - 52 48 - 52 53 - 54 53 - 54
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 30 5 - 30 5 - 50 5 - 50Maximum Height Difference m 30 30 30 30Pre-charged for m 20 20 30 30Charge R410A (Factory - Additional) kg 1.7 - 40g/m 1.7 - 40g/m 2.8 - 40g/m 2.8 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 11.43 11.43 15.18 15.18
Suggested Fuse Size A 16 16 20 20
Air Curtain £4,157 £4,687 £5,253 £5,523
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,177 £1,177 £1,549 £1,549
Retail Price £5,400 £5,930 £6,868 £7,138Suitable for installation above the door where whole unit will be visible
Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48
Ceiling mounting kit for model 25, part number 4034 retail price £65
ampair.co.uk | 01707 378 670 | [email protected] 167
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Free Hanging - Digital Inverter
Air Curtain RAV-CT201CH-M RAV-CT201CH-L RAV-CT251CH-M RAV-CT251CH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM1404ATP-ERAV-SM1404ATP-E RAV-SM1603AT-E RAV-SM1603AT-E
PERF
ORM
ANCE Horse Power 5 5 6 6
Heating Capacity kW 14.0 14.0 16.0 16.0Heating COP 2.63 2.82 3.12 3.27
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 2000 2000 2500 2500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 2210 - 490 260 - 2210 - 490 260 - 2710 - 490 260 - 2710 - 490Weight kg 115 117 147 149Standard Airflow l/s 844 1167 1056 1361Sound Pressure Level dB(A) 56 57 57 58
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 890 - 900 - 320 890 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320Weight kg 68 68 99 99Operating Range (Cooling - Heating) 46°C to -15°C / 15°C to -15°CStandard Airflow l/s 1167 1167 1717 1717Sound Pressure Level (Cooling - Heating) dB(A) 54 - 55 54 - 55 51 - 53 51 - 53
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 50 5 - 50 5 - 50 5 - 50Maximum Height Difference m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 2.8 - 40g/m 2.8 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 21.37 21.37 21.70 21.70
Suggested Fuse Size A 32 32 32 32
Air Curtain £6,020 £6,834 £6,841 £7,159
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,633 £1,633 £2,059 £2,059
Retail Price £7,719 £8,533 £8,966 £9,284Suitable for installation above the door where whole unit will be visible
Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48
Ceiling mounting kit for model 25, part number 4034 retail price £65
RBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 168
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Free Hanging - Super Digital Inverter
Air Curtain RAV-CT101CH-M RAV-CT101CH-L RAV-CT151CH-M RAV-CT151CH-M
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP804ATP-E RAV-SP804ATP-E RAV-SP1104AT-E RAV-SP1104AT8-E
PERF
ORM
ANCE Horse Power 3 3 4 4
Heating Capacity kW 8.0 8.0 11.2 11.2Heating COP 2.46 2.52 2.44 2.44
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1000 1000 1500 1500
Maximum Door Height m 3.0 3.2 3.0 3.0Dimensions (height - width - depth) 260 - 1210 - 490 260 - 1210 - 490 260 - 1710 - 490 260 - 1710 - 490Weight kg 54 57 85 85Standard Airflow l/s 422 583 633 633Sound Pressure Level dB(A) 54 55 55 55
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 550 - 780 - 290 550 - 780 - 290 1340 - 900 - 320 1340 - 900 - 320Weight kg 44 44 93 95Operating Range (Cooling - Heating) 43°C to -15°C / 15°C to -15°CStandard Airflow l/s 750 750 1683 1683Sound Pressure Level (Cooling - Heating) dB(A) 48 - 52 48 - 52 49 - 50 49 - 50
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 50 5 - 30 3 - 75 3 - 75Maximum Height Difference m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 1.7 - 40g/m 1.7 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 400 - 3 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 11.43 11.43 10.43 3.72 per Ph
Suggested Fuse Size A 16 16 16 10 per Ph
Air Curtain £4,157 £4,687 £5,253 £5,253
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,628 £1,628 £1,995 £2,184
Retail Price £5,851 £6,381 £7,314 £7,503Suitable for installation above the door where whole unit will be visible
Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48
Ceiling mounting kit for model 25, part number 4034 retail price £65
ampair.co.uk | 01707 378 670 | [email protected] 169
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Free Hanging - Super Digital Inverter
Air Curtain RAV-CT151CH-L RAV-CT151CH-L RAV-CT201CH-M RAV-CT201CH-M
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT-E RAV-SP1104AT8-E RAV-SP1404AT-E RAV-SP1404AT8-E
PERF
ORM
ANCE Horse Power 4 4 5 5
Heating Capacity kW 11.2 11.2 14.0 14.0Heating COP 2.65 2.65 2.63 2.63
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1500 1500 2000 2000
Maximum Door Height m 3.2 3.2 3.0 3.0Dimensions (height - width - depth) 260 - 1710 - 490 260 - 1710 - 490 260 - 2210 - 490 260 - 2210 - 490Weight kg 87 87 115 115Standard Airflow l/s 778 778 844 844Sound Pressure Level dB(A) 56 56 56 56
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320Weight kg 93 95 93 95Operating Range (Cooling - Heating) 46°C to -15°C / 15°C to -15°CStandard Airflow l/s 1683 1683 1717 1717Sound Pressure Level (Cooling - Heating) dB(A) 49 - 50 49 - 50 51 - 52 51 - 52
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 3 - 75 3 - 75 3 - 75 3 - 75Maximum Height Difference m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 230 - 1 - 50 400 - 3 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 10.43 3.72 per Ph 15.76 5.42 per Ph
Suggested Fuse Size A 16 10 per Ph 25 16 per Ph
Air Curtain £5,523 £5,523 £6,020 £6,020
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,995 £2,184 £2,205 £2,279
Retail Price £7,584 £7,773 £8,291 £8,365Suitable for installation above the door where whole unit will be visible
Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48
Ceiling mounting kit for model 25, part number 4034 retail price £65
RBC-AS41E £70 Retail
@amp_aircon | amp-air-conditioning 170
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Free Hanging - Super Digital Inverter
Air Curtain RAV-CT201CH-L RAV-CT201CH-L RAV-CT251CH-M RAV-CT251CH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1404AT-E RAV-SP1404AT8-E RAV-SP1604AT8-E RAV-SP1604AT8-E
PERF
ORM
ANCE Horse Power 5 5 6 6
Heating Capacity kW 14.0 14.0 16.0 16.0Heating COP 2.82 2.82 3.12 3.27
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 2000 2000 2500 2500
Maximum Door Height m 3.2 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 2210 - 490 260 - 2210 - 490 260 - 2710 - 490 260 - 2710 - 490Weight kg 117 117 147 149Standard Airflow l/s 1167 1167 1056 1361Sound Pressure Level dB(A) 57 57 57 58
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320Weight kg 93 95 95 95Operating Range (Cooling - Heating) 43°C to -15°C / 15°C to -15°CStandard Airflow l/s 1717 1717 1717 1717Sound Pressure Level (Cooling - Heating) dB(A) 51 - 52 51 - 52 51 - 53 51 - 53
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 3 - 75 3 - 75 3 - 75 3 - 75Maximum Height Difference m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 15.76 5.42 per Ph 6.66 per Ph 6.66 per Ph
Suggested Fuse Size A 25 16 per Ph 16 per Ph 16 per Ph
Air Curtain £6,834 £6,834 £6,841 £7,159
Remote Controller £66 £66 £66 £66
Outdoor Unit £2,205 £2,279 £2,426 £2,426
Retail Price £9,105 £9,179 £9,333 £9,651Suitable for installation above the door where whole unit will be visible
Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48
Ceiling mounting kit for model 25, part number 4034 retail price £65
ampair.co.uk | 01707 378 670 | [email protected] 171
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Cassette Type - Digital Inverter
Air Curtain RAV-CT101UH-M RAV-CT101UH-L RAV-CT151UH-M RAV-CT151UH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM804ATP-E RAV-SM804ATP-E RAV-SM1104ATP-ERAV-SM1104ATP-E
PERF
ORM
ANCE Horse Power 3 3 4 4
Heating Capacity kW 8.0 8.0 11.2 11.2Heating COP 2.46 2.52 2.44 2.65
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1000 1000 1500 1500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 1050 - 780 260 - 1050 - 780 260 - 1550 - 780 260 - 1550 - 780Weight kg 49 52 105 107Standard Airflow l/s 422 583 633 778Sound Pressure Level dB(A) 54 55 55 56
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 550 - 780 - 290 550 - 780 - 290 890 - 900 - 320 890 - 900 - 320Weight kg 44 44 68 68Operating Range (Cooling - Heating) 46°C to -15°C / 15°C to -15°CStandard Airflow l/s 750 750 1133 1133Sound Pressure Level (Cooling - Heating) dB(A) 48 - 52 48 - 52 53 - 54 53 - 54
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 30 5 - 30 5 - 50 5 - 50Maximum Height Difference m 30 30 30 30Pre-charged for m 20 20 30 30Charge R410A (Factory - Additional) kg 1.7 - 40g/m 1.7 - 40g/m 2.8 - 40g/m 2.8 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 11.43 11.43 15.18 15.18
Suggested Fuse Size A 16 16 20 20
Air Curtain £4,351 £4,994 £5296 £5,687
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,177 £1,177 £1,549 £1,549
Retail Price £5,594 £6,237 £6,911 £7,302Suitable for recessed installation
@amp_aircon | amp-air-conditioning 172
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Cassette Type - Digital Inverter
Air Curtain RAV-CT201UH-M RAV-CT201UH-L RAV-CT251UH-M RAV-CT251UH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM1404ATP-ERAV-SM1404ATP-E RAV-SM1603AT-E RAV-SM1603AT-E
PERF
ORM
ANCE Horse Power 5 5 6 6
Heating Capacity kW 14.0 14.0 16.0 16.0Heating COP 2.63 2.82 3.12 3.27
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 2000 2000 2500 2500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 2050 - 780 260 - 2050 - 780 260 - 2550 - 780 260 - 2550 - 780Weight kg 111 113 135 137Standard Airflow l/s 844 1167 1056 1361Sound Pressure Level dB(A) 56 57 57 58
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 890 - 900 - 320 890 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320Weight kg 68 68 99 99Operating Range (Cooling - Heating) 46°C to -15°C / 15°C to -15°CStandard Airflow l/s 1167 1167 1717 1717Sound Pressure Level (Cooling - Heating) dB(A) 54 - 55 54 - 55 51 - 53 51 - 53
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 50 5 - 50 5 - 50 5 - 50Maximum Height Difference m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 2.8 - 40g/m 2.8 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 21.37 21.37 21.70 21.70
Suggested Fuse Size A 32 32 32 32
Air Curtain £6,107 £6,887 £6,891 £7,626
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,633 £1,633 £2,059 £2,059
Retail Price £7,806 £8,586 £9,016 £9,751Suitable for recessed installation
ampair.co.uk | 01707 378 670 | [email protected] 173
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Cassette Type - Super Digital Inverter
Air Curtain RAV-CT101UH-M RAV-CT101UH-L RAV-CT151UH-M RAV-CT151UH-M
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP804ATP-E RAV-SP804ATP-E RAV-SP1104AT-E RAV-SP1104AT8-E
PERF
ORM
ANCE Horse Power 3 3 4 4
Heating Capacity kW 8.0 8.0 11.2 11.2Heating COP 2.46 2.52 2.44 2.44
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1000 1000 1500 1500
Maximum Door Height m 3.0 3.2 3.0 3.0Dimensions (height - width - depth) 260 - 1050 - 780 260 - 1050 - 780 260 - 1550 - 780 260 - 1550 - 780Weight kg 49 52 105 105Standard Airflow l/s 422 583 633 633Sound Pressure Level dB(A) 54 55 55 55
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 550 - 780 - 290 550 - 780 - 290 1340 - 900 - 320 1340 - 900 - 320Weight kg 44 44 93 95Operating Range (Cooling - Heating) 43°C to -15°C / 15°C to -15°CStandard Airflow l/s 750 750 1683 1683Sound Pressure Level (Cooling - Heating) dB(A) 48 - 52 48 - 52 49 - 50 49 - 50
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 50 5 - 50 3 - 75 3 - 75Maximum Height Difference m 30 30 30 30Pre-charged for m 20 20 30 30Charge R410A (Factory - Additional) kg 1.7 - 40g/m 1.7 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 400 - 3 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 11.43 11.43 10.43 3.72 per Ph
Suggested Fuse Size A 16 16 16 10 per Ph
Air Curtain £4,351 £4,994 £5,296 £5,296
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,628 £1,628 £1,995 £2,184
Retail Price £6,045 £6,688 £7,357 £7,546Suitable for recessed installation
RBC-AMT32E £50 Retail
@amp_aircon | amp-air-conditioning 174
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Cassette Type - Super Digital Inverter
Air Curtain RAV-CT151UH-L RAV-CT151UH-L RAV-CT201UH-M RAV-CT201UH-M
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT-E RAV-SP1104AT8-E RAV-SP1404AT-E RAV-SP1404AT8-E
PERF
ORM
ANCE Horse Power 4 4 5 5
Heating Capacity kW 11.2 11.2 14.0 14.0Heating COP 2.65 2.65 2.63 2.63
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1500 1500 2000 2000
Maximum Door Height m 3.2 3.2 3.0 3.0Dimensions (height - width - depth) 260 - 1550 - 780 260 - 1550 - 780 260 - 2050 - 780 260 - 2050 - 780Weight kg 107 107 111 111Standard Airflow l/s 778 778 844 844Sound Pressure Level dB(A) 56 56 56 56
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320Weight kg 93 95 93 95Operating Range (Cooling - Heating) 46°C to -15°C / 15°C to -15°CStandard Airflow l/s 1683 1683 1717 1717Sound Pressure Level (Cooling - Heating) dB(A) 49 - 50 49 - 50 51 - 52 51 - 52
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 3 - 75 3 - 75 3 - 75 3 - 75Maximum Height Difference m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 230 - 1 - 50 400 - 3 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 10.43 3.72 per Ph 15.76 5.42 per Ph
Suggested Fuse Size A 16 10 per Ph 25 16 per Ph
Air Curtain £5,687 £5,687 £6,107 £6,107
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,995 £2,184 £2,205 £2,279
Retail Price £7,748 £7,937 £8,378 £8,452Suitable for recessed installation
ampair.co.uk | 01707 378 670 | [email protected] 175
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Cassette Type - Super Digital Inverter
Air Curtain RAV-CT201UH-L RAV-CT201UH-L RAV-CT251UH-M RAV-CT251UH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1404AT-E RAV-SP1404AT8-E RAV-SP1604AT8-E RAV-SP1604AT8-E
PERF
ORM
ANCE Horse Power 5 5 6 6
Heating Capacity kW 14.0 14.0 16.0 16.0Heating COP 2.82 2.82 3.12 3.27
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 2000 2000 2500 2500
Maximum Door Height m 3.2 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 2050 - 780 260 - 2050 - 780 260 - 2550 - 780 260 - 2550 - 780Weight kg 113 113 135 137Standard Airfl ow l/s 1167 1167 1056 1361Sound Pressure Level dB(A) 57 57 57 58
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320Weight kg 93 95 95 95Operating Range (Cooling - Heating) 43°C to -15°C / 15°C to -15°CStandard Airfl ow l/s 1717 1717 1717 1717Sound Pressure Level (Cooling - Heating) dB(A) 51 - 52 51 - 52 51 - 53 51 - 53
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 3 - 75 3 - 75 3 - 75 3 - 75Maximum Height Diff erence m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 15.76 5.42 per Ph 6.66 per Ph 6.66 per Ph
Suggested Fuse Size A 25 16 per Ph 16 per Ph 16 per Ph
Air Curtain £6,887 £6,887 £6,891 £7,626
Remote Controller £66 £66 £66 £66
Outdoor Unit £2,205 £2,279 £2,426 £2,426
Retail Price £9,158 £9,232 £9,383 £10,118Suitable for recessed installation
RBC-AMS41E £66 Retail
@amp_aircon | amp-air-conditioning 176
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Built-In - Digital Inverter
Air Curtain RAV-CT101BH-M RAV-CT101BH-L RAV-CT151BH-M RAV-CT151BH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM804ATP-E RAV-SM804ATP-E RAV-SM1104ATP-ERAV-SM1104ATP-E
PERF
ORM
ANCE Horse Power 3 3 4 4
Heating Capacity kW 8.0 8.0 11.2 11.2Heating COP 2.46 2.52 2.44 2.65
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1000 1000 1500 1500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 405-485 - 1105 - 720 405-485 - 1105 - 720 405-485 - 1605 - 720 405-485 - 1605 - 720
Weight kg 77 80 113 115Standard Airflow l/s 422 583 633 778Sound Pressure Level dB(A) 54 55 55 56
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 550 - 780 - 290 550 - 780 - 290 890 - 900 - 320 890 - 900 - 320Weight kg 44 44 68 68Operating Range (Cooling - Heating) 46°C to -15°C / 15°C to -15°CStandard Airflow l/s 750 750 1133 1133Sound Pressure Level (Cooling - Heating) dB(A) 48 - 52 48 - 52 53 - 54 53 - 54
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 30 5 - 30 5 - 50 5 - 50Maximum Height Difference m 30 30 30 30Pre-charged for m 20 20 30 30Charge R410A (Factory - Additional) kg 1.7 - 40g/m 1.7 - 40g/m 2.8 - 40g/m 2.8 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 11.43 11.43 15.18 15.18
Suggested Fuse Size A 16 16 20 20
Air Curtain £4,847 £4,884 £5,831 £6,099
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,177 £1,177 £1,549 £1,549
Retail Price £6,090 £6,127 £7,446 £7,714Suitable for recessed ducted installation
ampair.co.uk | 01707 378 670 | [email protected] 177
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Built-In - Digital Inverter
Air Curtain RAV-CT201BH-M RAV-CT201BH-L RAV-CT251BH-M RAV-CT251BH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SM1404ATP-ERAV-SM1404ATP-E RAV-SM1603AT-E RAV-SM1603AT-E
PERF
ORM
ANCE Horse Power 5 5 6 6
Heating Capacity kW 14.0 14.0 16.0 16.0Heating COP 2.63 2.82 3.12 3.27
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 2000 2000 2500 2500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 405-485 - 2105 - 720 405-485 - 2105 - 720 405-485 - 2605 - 720 405-485 - 2605 - 720
Weight kg 143 145 185 189Standard Airflow l/s 844 1167 1056 1361Sound Pressure Level dB(A) 56 57 57 58
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 890 - 900 - 320 890 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320Weight kg 68 68 99 99Operating Range (Cooling - Heating) 46°C to -15°C / 15°C to -15°CStandard Airflow l/s 1167 1167 1717 1717Sound Pressure Level (Cooling - Heating) dB(A) 54 - 55 54 - 55 51 - 53 51 - 53
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 50 5 - 50 5 - 50 5 - 50Maximum Height Difference m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 2.8 - 40g/m 2.8 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 21.37 21.37 21.70 21.70
Suggested Fuse Size A 32 32 32 32
Air Curtain £6,357 £6,967 £7,196 £7,863
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,633 £1,633 £2,059 £2,059
Retail Price £8,056 £8,666 £9,321 £9,988Suitable for recessed ducted installation
RBC-AMS54E-ES £105 Retail
@amp_aircon | amp-air-conditioning 178
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Built-In - Super Digital Inverter
Air Curtain RAV-CT101BH-M RAV-CT101BH-L RAV-CT151BH-M RAV-CT151BH-M
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP804ATP-E RAV-SP804ATP-E RAV-SP1104AT-E RAV-SP1104AT8-E
PERF
ORM
ANCE Horse Power 3 3 4 4
Heating Capacity kW 8.0 8.0 11.2 11.2Heating COP 2.46 2.52 2.44 2.44
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1000 1000 1500 1500
Maximum Door Height m 3.0 3.2 3.0 3.0Dimensions (height - width - depth) 405-485 - 1105 - 720 405-485 - 1105 - 720 405-485 - 1605 - 720 405-485 - 1605 - 720
Weight kg 77 80 113 113Standard Airflow l/s 422 583 633 633Sound Pressure Level dB(A) 54 55 55 55
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 550 - 780 - 290 550 - 780 - 290 1340 - 900 - 320 1340 - 900 - 320Weight kg 44 44 93 95Operating Range (Cooling - Heating) 43°C to -15°C / 15°C to -15°CStandard Airflow l/s 750 750 1683 1683Sound Pressure Level (Cooling - Heating) dB(A) 48 - 52 48 - 52 49 - 50 49 - 50
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 5 - 50 5 - 30 3 - 75 3 - 75Maximum Height Difference m 30 30 30 30Pre-charged for m 20 20 30 30Charge R410A (Factory - Additional) kg 1.7 - 40g/m 1.7 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 400 - 3 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 11.43 11.43 10.43 3.72 per Ph
Suggested Fuse Size A 16 16 16 10 per Ph
Air Curtain £4,847 £4,884 £5,831 £5,831
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,628 £1,628 £1,995 £2,184
Retail Price £6,541 £6,578 £7,892 £8,081Suitable for recessed ducted installation
ampair.co.uk | 01707 378 670 | [email protected] 179
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Built-In - Super Digital Inverter
Air Curtain RAV-CT151BH-L RAV-CT151BH-L RAV-CT201BH-M RAV-CT201BH-M
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1104AT-E RAV-SP1104AT8-E RAV-SP1404AT-E RAV-SP1404AT8-E
PERF
ORM
ANCE Horse Power 4 4 5 5
Heating Capacity kW 11.2 11.2 14.0 14.0Heating COP 2.65 2.65 2.63 2.63
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1500 1500 2000 2000
Maximum Door Height m 3.2 3.2 3.0 3.0Dimensions (height - width - depth) 405-485 - 1605 - 720 405-485 - 1605 - 720 405-485 - 2105 - 720 405-485 - 2105 - 720
Weight kg 115 115 143 143Standard Airflow l/s 778 778 844 844Sound Pressure Level dB(A) 56 56 56 56
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320Weight kg 93 95 93 95Operating Range (Cooling - Heating) 46°C to -15°C / 15°C to -15°CStandard Airflow l/s 1683 1683 1717 1717Sound Pressure Level (Cooling - Heating) dB(A) 49 - 50 49 - 50 51 - 52 51 - 52
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 3 - 75 3 - 75 3 - 75 3 - 75Maximum Height Difference m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 230 - 1 - 50 400 - 3 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 10.43 3.72 per Ph 15.76 5.42 per Ph
Suggested Fuse Size A 16 10 per Ph 25 16 per Ph
Air Curtain £6,099 £6,099 £6,357 £6,357
Remote Controller £66 £66 £66 £66
Outdoor Unit £1,995 £2,184 £2,205 £2,279
Retail Price £8,160 £8,349 £8,628 £8,702Suitable for recessed ducted installation
RBC-AS41E £70 Retail
@amp_aircon | amp-air-conditioning 180
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Built-In - Super Digital Inverter
Air Curtain RAV-CT201BH-L RAV-CT201BH-L RAV-CT251BH-M RAV-CT251BH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Outdoor Unit RAV-SP1404AT-E RAV-SP1404AT8-E RAV-SP1604AT8-E RAV-SP1604AT8-E
PERF
ORM
ANCE Horse Power 5 5 6 6
Heating Capacity kW 14.0 14.0 16.0 16.0Heating COP 2.82 2.82 3.12 3.27
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 2000 2000 2500 2500
Maximum Door Height m 3.2 3.2 3.0 3.2Dimensions (height - width - depth) 405-485 - 2105 - 720 405-485 - 2105 - 720 405-485 - 2605 - 720 405-485 - 2605 - 720
Weight kg 145 145 185 189Standard Airflow l/s 1167 1167 1056 1361Sound Pressure Level dB(A) 57 57 57 58
OU
TDO
OR
UN
IT
SPEC
IFIC
ATIO
N
Dimensions (height - width - depth) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320Weight kg 93 95 95 95Operating Range (Cooling - Heating) 43°C to -15°C / 15°C to -15°CStandard Airflow l/s 1717 1717 1717 1717Sound Pressure Level (Cooling - Heating) dB(A) 51 - 52 51 - 52 51 - 53 51 - 53
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”Pipe Limits (min - max) m 3 - 75 3 - 75 3 - 75 3 - 75Maximum Height Difference m 30 30 30 30Pre-charged for m 30 30 30 30Charge R410A (Factory - Additional) kg 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m 3.1 - 40g/m
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50Interconnecting Cables 3 core & earth 3 core & earth 3 core & earth 3 core & earthMaximum Running Current A 15.76 5.42 per Ph 6.66 per Ph 6.66 per Ph
Suggested Fuse Size A 25 16 per Ph 16 per Ph 16 per Ph
Air Curtain £6,967 £6,967 £7,196 £7,863
Remote Controller £66 £66 £66 £66
Outdoor Unit £2,205 £2,279 £2,426 £2,426
Retail Price £9,238 £9,312 £9,688 £10,355Suitable for recessed ducted installation
ampair.co.uk | 01707 378 670 | [email protected] 181
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Free Hanging - VRF
Air Curtain RAV-CT101CH-M RAV-CT101CH-L RAV-CT151CH-M RAV-CT151CH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Accessory Kit MMD-ODH1 MMD-ODH1 MMD-ODH1 MMD-ODH1
PERF
ORM Capacity Code 3 3 4 4
Heating Capacity kW 8.0 8.0 11.2 11.2
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1000 1000 1500 1500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 1210 - 490 260 - 1210 - 490 260 - 1710 - 490 260 - 1710 - 490Weight kg 54 57 85 87Standard Airflow l/s 422 583 633 778Sound Pressure Level dB(A) 54 55 55 56
PIPE
WO
RK Gas Pipe Sizes in 5/8” 5/8” 5/8” 5/8”Liquid Pipe Sizes in 3/8” 3/8” 3/8” 3/8”
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Power Input kW 0.56 0.82 0.74 1.11Suggested Fuse Size A 10 10 10 10
Air Curtain £4,157 £4,687 £5,253 £5,523
Remote Controller £66 £66 £66 £66
Accessory Kit £856 £856 £856 £856
Retail Price £5,079 £5,609 £6,175 £6,445
Air Curtain RAV-CT201CH-M RAV-CT201CH-L RAV-CT251CH-M RAV-CT251CH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Accessory Kit MMD-ODH1 MMD-ODH1 MMD-ODH1 MMD-ODH1
PERF
ORM Capacity Code 5 5 6 6
Heating Capacity kW 14.0 14.0 16.0 16.0
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 2000 2000 2500 2500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 2210 - 490 260 - 2210 - 490 260 - 2710 - 490 260 - 2710 - 490Weight kg 115 117 147 149Standard Airflow l/s 844 1167 1056 1361Sound Pressure Level dB(A) 56 57 57 58
PIPE
WO
RK Gas Pipe Sizes in 5/8” 5/8” 5/8” 5/8”Liquid Pipe Sizes in 3/8” 3/8” 3/8” 3/8”
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Power Input kW 0.93 1.64 1.11 1.92Suggested Fuse Size A 10 16 10 16
Air Curtain £6,020 £6,834 £6,841 £7,159
Remote Controller £66 £66 £66 £66
Accessory Kit £856 £856 £856 £856
Retail Price £6,950 £7,756 £7,763 £8,081Suitable for installation above the door where whole unit will be visible
Ceiling mounting kit for model 100 to 200, part number 3871 retail price £50
Ceiling mounting kit for model 25, part number 4034 retail price £68
@amp_aircon | amp-air-conditioning 182
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Cassette Type - VRF
Air Curtain RAV-CT101UH-M RAV-CT101UH-L RAV-CT151UH-M RAV-CT151UH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Accessory Kit MMD-ODH1 MMD-ODH1 MMD-ODH1 MMD-ODH1
PERF
ORM Capacity Code 3 3 4 4
Heating Capacity kW 8.0 8.0 11.2 11.2
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1000 1000 1500 1500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 1050 - 780 260 - 1050 - 780 260 - 1550 - 780 260 - 1550 - 780Weight kg 49 52 105 107Standard Airflow l/s 422 583 633 778Sound Pressure Level dB(A) 54 55 55 56
PIPE
WO
RK Gas Pipe Sizes in 5/8” 5/8” 5/8” 5/8”Liquid Pipe Sizes in 3/8” 3/8” 3/8” 3/8”
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Power Input kW 0.56 0.82 0.74 1.11Suggested Fuse Size A 10 10 10 10
Air Curtain £4,351 £4,994 £5,296 £5,687
Remote Controller £66 £66 £66 £66
Accessory Kit £856 £856 £856 £856
Retail Price £5,273 £5,916 £6,218 £6,609
Air Curtain RAV-CT201UH-M RAV-CT201UH-L RAV-CT251UH-M RAV-CT251UH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Accessory Kit MMD-ODH1 MMD-ODH1 MMD-ODH1 MMD-ODH1
PERF
ORM Capacity Code 5 5 6 6
Heating Capacity kW 14.0 14.0 16.0 16.0
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 2000 2000 2500 2500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 260 - 2050 - 780 260 - 2050 - 780 260 - 2550 - 780 260 - 2550 - 780Weight kg 111 113 135 137Standard Airflow l/s 844 1167 1056 1361Sound Pressure Level dB(A) 56 57 57 58
PIPE
WO
RK Gas Pipe Sizes in 5/8” 5/8” 5/8” 5/8”Liquid Pipe Sizes in 3/8” 3/8” 3/8” 3/8”
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Power Input kW 0.93 1.64 1.11 1.92Suggested Fuse Size A 10 16 10 16
Air Curtain £6,107 £6,887 £6,891 £7,626
Remote Controller £66 £66 £66 £66
Accessory Kit £856 £856 £856 £856
Retail Price £7,029 £7,809 £7,813 £8,548Suitable for recessed installation
ampair.co.uk | 01707 378 670 | [email protected] 183
Appl
ied
& A
2W
Applied Products & Air to WaterAir Curtain - Built-In - VRF
Air Curtain RAV-CT101BH-M RAV-CT101BH-L RAV-CT151BH-M RAV-CT151BH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Accessory Kit MMD-ODH1 MMD-ODH1 MMD-ODH1 MMD-ODH1
PERF
ORM Capacity Code 3 3 4 4
Heating Capacity kW 8.0 8.0 11.2 11.2
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 1000 1000 1500 1500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 405-485 - 1105 - 720 405-485 - 1105 - 720 405-485 - 1605 - 720 405-485 - 1605 - 720
Weight kg 77 80 113 115Standard Airflow l/s 422 583 633 778Sound Pressure Level dB(A) 54 55 55 56
PIPE
WO
RK Gas Pipe Sizes in 5/8” 5/8” 5/8” 5/8”Liquid Pipe Sizes in 3/8” 3/8” 3/8” 3/8”
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Power Input kW 0.56 0.82 0.74 1.11Suggested Fuse Size A 10 10 10 10
Air Curtain £4,847 £4,884 £5,831 £6,099
Remote Controller £66 £66 £66 £66
Accessory Kit £856 £856 £856 £856
Retail Price £5,769 £5,806 £6,753 £7,021
Air Curtain RAV-CT201BH-M RAV-CT201BH-L RAV-CT251BH-M RAV-CT251BH-L
Remote Controller RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E
Accessory Kit MMD-ODH1 MMD-ODH1 MMD-ODH1 MMD-ODH1
PERF
ORM Capacity Code 5 5 6 6
Heating Capacity kW 14.0 14.0 16.0 16.0
AIR
CURT
AIN
SPE
CIFI
CATI
ON Door Width mm 2000 2000 2500 2500
Maximum Door Height m 3.0 3.2 3.0 3.2Dimensions (height - width - depth) 405-485 - 2105 - 720 405-485 - 2105 - 720 405-485 - 2605 - 720 405-485 - 2605 - 720
Weight kg 143 145 185 189Standard Airflow l/s 844 1167 1056 1361Sound Pressure Level dB(A) 56 57 57 58
PIPE
WO
RK Gas Pipe Sizes in 5/8” 5/8” 5/8” 5/8”Liquid Pipe Sizes in 3/8” 3/8” 3/8” 3/8”
POW
ER
Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50Power Input kW 0.93 1.64 1.11 1.92Suggested Fuse Size A 10 16 10 16
Air Curtain £6,357 £6,967 £7,196 £7,863
Remote Controller £66 £66 £66 £66
Accessory Kit £856 £856 £856 £856
Retail Price £7,279 £7,889 £8,118 £8,785Suitable for recessed ducted installation
@amp_aircon | amp-air-conditioning 184
Appl
ied
& A
2W
Applied Products & Air to WaterEstia Introduction
With its best in class COP performance, Estia air to water heat pump system delivers more heating power with less energy consumption. Estia uses high quality components and material which contribute to the overall savings in energy consumption. With the Toshiba advanced inverter, Estia air to water heat pump systems deliver the heating capacity required; thus consuming only the necessary electricity.
Easy to installQuick and easy to install. The hydro module unit can be placed safely in the most suitable place within the house. The compact outdoor unit can be placed anywhere outside the house or on a balcony, thanks to extensive piping options.
Environmentally consciousThe use of Toshiba Estía heat pumps contributes to the reduction of global CO2 emissions and limits the use of fossil fuels or other non-renewable energy primary sources. Whenever required for maintenance, all the R410A refrigerant (non ozone depleting) can be completely pumped back to the outdoor unit through the powerful embedded Toshiba “pump down” operation.
One system, multiple solutionsEstía heat pump systems can be used in combination with different types of emitters: existing heating low temperature radiators, floor heating or fan coil units.
IncentivesEvery country in Europe has already issued or is in the process of promoting incentive schemes for the installation of heat pump systems. Grants or tax rebates are calculated using the nominal COP as a reference, with progressively annual efficiency entering into consideration. The installation of Estía air to water heat pump systems with high nominal COP and outstandingly high partial load COP, thanks to its inverter DC Twin rotary compressor, guarantees to match most local governments requirements.
The right temperature at the right timeIt can produce water at different temperatures for several applications simultaneously. Toshiba Estía air to water heat pump systems operate smoothly both with low outdoor air temperature down to -20 °C in winter and up to 43 °C in the summer season.
ampair.co.uk | 01707 378 670 | [email protected] 185
Appl
ied
& A
2W
Applied Products & Air to WaterEstia - Outdoor Units - Standard - Single Phase
Outdoor Unit HWS-804H-E1 HWS-1104H-E1 HWS-1404H-E1
PERF
ORM
ANCE
Heating Capacity *1 kW 8.0 11.2 14.0
Rated Water Flow (Heating Condition 1) l/m 22.90 32.10 40.10
Input Power (Heating Condition 1) kW 1.79 2.30 3.11
COP (Heating Condition 1) 4.46 4.88 4.50
OPE
RAT-
ING
RAN
GES Operating Temp. Range Hydro/Outdoor °C 5°C to 32°C / -20°C to 43°C
Operating Humid Range Hydro/Outdoor 15% to 85% / 15% to 100%
PHYS
I-CA
L Unit Dimensions (H-W-D) mm 890 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 63 92 92
SOU
ND Sound Pressure level - Hydro dB(A) 27 29 29
Sound Pressure level - Outdoor dB(A) 49 49 51
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”
Pipe Limits (Max Run - Height Diff.) m 30 - 30 30 - 30 30 - 30
Pre-charged for m 30 30 30
Charge R410A (Factory - Additional) kg 1.8 - n/a 2.7 - n/a 2.7 - n/a
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Hydro Unit Running Current Heating A 0.44 0.66 0.66
Hydro Unit Power Input Heating kW 0.06 0.09 0.09
Outdoor Unit running Current Heating A 7.97 10.08 13.74
Outdoor Unit Power Input Heating Kw 1.73 2.21 3.02
Total Running Current heating A 8.41 10.74 14.40
Suggested Fuse Size A 20 25 25
Outdoor Unit £1,936 £2,138 £2,515
Retail Price £1,936 £2,138 £2,515*1 Heating performance measurement conditions: outside air temperature 7°C, water supply temperature 30°C, outlet water temperature 35°C,
refrigerant piping length 7.5m (no height difference)
Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail
Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail
Wired Remote Controller for room air temperature control. HWS-AMS11E, £90 Retail
@amp_aircon | amp-air-conditioning 186
Appl
ied
& A
2W
Applied Products & Air to WaterEstia - Outdoor Units - Standard - Three Phase
Outdoor Unit HWS-1104H8-E1 HWS-1404H8-E1 HWS-1604H8-E1PE
RFO
RMAN
CE
Heating Capacity *1 kW 11.2 14.0 16.0
Rated Water Flow (Heating Condition 1) l/m 32.10 40.10 45.80
Input Power (Heating Condition 1) kW 2.34 3.16 3.72
COP (Heating Condition 1) 4.80 4.44 4.30
OPE
RAT-
ING
RAN
GES Operating Temp. Range Hydro/Outdoor °C 5°C to 32°C / -20°C to 43°C
Operating Humid Range Hydro/Outdoor 15% to 85% / 15% to 100%
PHYS
I-CA
L Unit Dimensions (H-W-D) mm 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 93 93 93
SOU
ND Sound Pressure level - Hydro dB(A) 29 29 29
Sound Pressure level - Outdoor dB(A) 49 51 52
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”
Pipe Limits (Max Run - Height Diff.) m 30 - 30 30 - 30 30 - 30
Pre-charged for m 30 30 30
Charge R410A (Factory - Additional) kg 2.7 - n/a 2.7 - n/a 2.7 - n/a
POW
ER
Power Supply (Outdoor) V-Ph-Hz 400 - 3 - 50 400 - 3 - 50 400 - 3 - 50
Hydro Unit Running Current Heating A 0.66 0.66 0.66
Hydro Unit Power Input Heating kW 0.09 0.09 0.09
Outdoor Unit running Current Heating A 3.73 per Ph 5.01 per Phase 5.94 per Phase
Outdoor Unit Power Input Heating Kw 2.25 3.07 3.63
Total Running Current heating A 4.39 per Phase 5.67 per Phase 6.60 per Phase
Suggested Fuse Size A 16 per Phase 16 per Phase 16 per Phase
Outdoor Unit £2,504 £2,706 £3,075
Retail Price £2,504 £2,706 £3,075*1 Heating performance measurement conditions: outside air temperature 7°C, water supply temperature 30°C, outlet water temperature 35°C,
refrigerant piping length 7.5m (no height difference)
Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail
Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail
Wired Remote Controller for room air temperature control. HWS-AMS11E, £90 Retail
ampair.co.uk | 01707 378 670 | [email protected] 187
Appl
ied
& A
2W
Applied Products & Air to WaterEstia - Hot Water Tanks - Standard
Domestic Hot Water Tank HWS-1501CSHM3-UK HWS-2101CSHM3-UK HWS-3001CSHM3-UK
PERF
ORM
ANCE
Water Volume Liters 150 210 300
Maximum Water Temperature °C 75 75 75
Electric Heater kW 2.75 2.75 2.75
Standing Heat Loss kWh/day 1.45 1.91 2.52
Nominal Storage Capacity of Units liter - kg 150 - 181 210 - 251 300 - 360
OPE
RATI
NG
RAN
GES
Maximum Water Supply Pressure to Prv Mpa-bar 1.6 - 16.0 1.6 - 16.0 1.6 - 16.0
Operating Pressure of Unit Mpa-bar 0.35 - 3.5 0.35 - 3.5 0.35 - 3.5
Expansion Vessel Charge Pressure Mpa-bar 0.35 - 3.5 0.35 - 3.5 0.35 - 3.5
Expansion Valve Setting Mpa-bar 0.6 - 6.0 0.6 - 6.0 0.6 - 6.0
Maximum Primary Working Pressure Mpa-bar 0.3 - 3.0 0.3 - 3.0 0.3 - 3.0Opening Temperature of T&P Relief Valve °C 90 90 90
Opening Pressure of T&P Relief Valve Mpa-bar 1.0 - 10 1.0 - 10 1.0 - 10
PHYS
ICAL
Material Stainless Steel
Insulation CFC/HCFC free polyurethane foam
Height mm 1090 1474 2040
Diameter mm 550 550 550
Weight Net kg 31 41 60
POW
ER Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 16 16 16
Domestic Hot Water Tank £987 £1,151 £1,352
Retail Price £987 £1,151 £1,352
@amp_aircon | amp-air-conditioning 188
Appl
ied
& A
2W
Applied Products & Air to WaterEstia - Hydro Units - Standard
Hydro Unit HWS-804XWHM3-E1 HWS-804XWHT6-E1
Remote Controller HWS-AMS11E HWS-AMS11E
WAT
ER P
IPIN
G
Water Piping Maximum Length None None
Water Piping Max. Height Difference m 7 7
Water Piping Minimum Flow Rate l/m 13+ 17+
Water Piping Max. Working Water Pres. Kpa 300 300
HEA
T EX
CHAN
GER Heat Exchanger Plate-type Heat Exchanger
Heat Exchanger Type Brazed Plate Brazed Plate
Heat Exchanger Water Volume liters 0.67 0.67
Heat Exchanger Minimum Flow Rate l/m 13 13
PUM
P D
ETAI
LS
Circulating Pump Max Motor Output W 125 190
Circulating Pump Flow Rate l/m 22.9 32.1
Circulating Pump Type Non-Self suction centrifugal Pump
Water Pump Power Input W 48 48
Water Pump Delivery Head m 6.3 6.3
PHYS
ICAL
Unit Dimensions (H-W-D) mm 925 - 525 - 355 925 - 525 - 355
Weight kg 50 50
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8”
Sound Pressure level dB(A) 27 27
OPE
RATI
NG
RAN
GE Expansion Vessel Volume Liters 12 12
Expansion Vessel Initial Pressure Mpa-Bar 0.1 - 1.0 0.1 - 1.0
Pressure Relief Valve Operating Pressure Mpa-Bar 0.3 - 3.0 0.3 - 3.0
Water Temperature Range Heating °C 20 - 55 20 - 55
POW
ER
Back up Heater Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50
Back up Heater Power - Max Current A 3.0 - 13 6.0 - 13 (13Ax2P)
Hot Water Cylinder Heater power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Hot Water Cylinder Heater Max. Current A 12.0 12.0
Hydro Unit £2,878 £2,990
Remote Controller £90 £90
Retail Price £2,968 £3,080
System Retail Prices (Excluding domestic hot water tank)
Combined with HWS-804H-E1 Outdoor Unit £4,904 £5,016
Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £55 retail
Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £79 Retail
ampair.co.uk | 01707 378 670 | [email protected] 189
Appl
ied
& A
2W
Applied Products & Air to WaterEstia - Hydro Units - Standard
Hydro Unit HWS-1404XWHM3-E1 HWS-1404XWHT6-E1 HWS-1404XWHT9-E1
Remote Controller HWS-AMS11E HWS-AMS11E HWS-AMS11E
WAT
ER P
IPIN
G
Water Piping Maximum Length None None None
Water Piping Max. Height Difference m 7 7 7
Water Piping Minimum Flow Rate l/m 17+ 17+ 17+
Water Piping Max. Working Water Pres. Kpa 300 300 300
HEA
T EX
CHAN
GER Heat Exchanger Plate-type Heat Exchanger
Heat Exchanger Type Brazed Plate Brazed Plate Brazed Plate
Heat Exchanger Water Volume liters 1.18 1.18 1.18
Heat Exchanger Minimum Flow Rate l/m 17.5 17.5 17.5
PUM
P D
ETAI
LS
Circulating Pump Max Motor Output W 190 190 190
Circulating Pump Flow Rate l/m 32.1 40.1 45.8
Circulating Pump Type Non-Self suction centrifugal Pump
Water Pump Power Input W 87 87 87
Water Pump Delivery Head m 8.8 8.8 8.8
PHYS
ICAL
Unit Dimensions (H-W-D) mm 925 - 525 - 355 925 - 525 - 355 925 - 525 - 355
Weight kg 54 54 54
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”
Sound Pressure level dB(A) 29 29 29
OPE
RATI
NG
RAN
GE Expansion Vessel Volume Liters 12 12 12
Expansion Vessel Initial Pressure Mpa-Bar 0.1 - 1.0 0.1 - 1.0 0.1 - 1.0
Pressure Relief Valve Operating Pressure Mpa-Bar 0.3 - 3.0 0.3 - 3.0 0.3 - 3.0
Water Temperature Range Heating °C 20 - 55 20 - 55 20 - 55
POW
ER
Back up Heater Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50
Back up Heater Power - Max Current A 3.0 - 13 6.0 - 13 (13Ax2P) 9.0 - 13 (13Ax3P)
Hot Water Cylinder Heater power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Hot Water Cylinder Heater Max. Current A 12.0 12.0 12.0
Hydro Unit £3,669 £3,782 £3,801
Remote Controller £90 £90 £90
Retail Price £3,759 £3,872 £3,891
System Retail Prices (Excluding domestic hot water tank)
Combined with HWS-1104H-E1 Outdoor Unit £5,897 £6,010 £6,029
Combined with HWS-1404H-E1 Outdoor Unit £6,274 £6,387 £6,406
Combined with HWS-1104H8-E1 Outdoor Unit £6,263 £6,376 £6,395
Combined with HWS-1404H8-E1 Outdoor Unit £6,465 £6,578 £6,597
Combined with HWS-1604H8-E1 Outdoor Unit £6,834 £6,947 £6,966
Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail
Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail
@amp_aircon | amp-air-conditioning 190
Appl
ied
& A
2W
Applied Products & Air to WaterEstia - Outdoor Units - High Temperature - Single Phase
Outdoor Unit HWS-P804HR-E1 HWS-P1104HR-E1PE
RFO
RMAN
CE
Heating Capacity *1 kW 8.0 11.2
Rated Water Flow (Heating Condition 1) l/m 22.90 32.10
Input Power (Heating Condition 1) kW 1.68 2.30
COP (Heating Condition 1) 4.76 4.88
OPE
RAT-
ING
RAN
GES Operating Temp. Range Hydro/Outdoor °C 5°C to 32°C / -20°C to 43°C
Operating Humid Range Hydro/Outdoor 15% to 85% / 15% to 100%
PHYS
I-CA
L Unit Dimensions (H-W-D) mm 1340 - 900 - 320 1340 - 900 - 320
Weight (Indoor - Outdoor) kg 92 92
SOU
ND Sound Pressure level - Hydro dB(A) 27 29
Sound Pressure level - Outdoor dB(A) 49 49
REFR
IGER
ANT
&
PIPE
WO
RK
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8”
Pipe Limits (Max Run - Height Diff.) m 30 - 30 30 - 30
Pre-charged for m 30 30
Charge R410A (Factory - Additional) kg 2.7 - n/a 2.7 - n/a
POW
ER
Power Supply (Outdoor) V-Ph-Hz 230 - 1 - 50 230 - 1 - 50
Hydro Unit Running Current Heating A 0.44 0.66
Hydro Unit Power Input Heating kW 0.06 0.09
Outdoor Unit running Current Heating A 7.57 10.33
Outdoor Unit Power Input Heating Kw 1.62 2.21
Total Running Current heating A 8.01 10.99
Suggested Fuse Size A 25 25
Outdoor Unit £2,517 £2,557
Retail Price £2,517 £2,557*1 Heating performance measurement conditions: outside air temperature 7°C, water supply temperature 30°C, outlet water temperature 35°C,
refrigerant piping length 7.5m (no height difference)
Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail
Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail
Wired Remote Controller for room air temperature control. HWS-AMS11E, £90 Retail
ampair.co.uk | 01707 378 670 | [email protected] 191
Appl
ied
& A
2W
Applied Products & Air to WaterEstia - Hot Water Tanks - High Temperature
Domestic Hot Water Tank HWS-1501CSHM3-UK HWS-2101CSHM3-UK HWS-3001CSHM3-UK
PERF
ORM
ANCE
Water Volume Liters 150 210 300
Maximum Water Temperature °C 75 75 75
Electric Heater kW 2.75 2.75 2.75
Standing Heat Loss kWh/day 1.45 1.91 2.52
Nominal Storage Capacity of Units liter - kg 150 - 181 210 - 251 300 - 360
OPE
RATI
NG
RAN
GES
Maximum Water Supply Pressure to Prv Mpa-bar 1.6 - 16.0 1.6 - 16.0 1.6 - 16.0
Operating Pressure of Unit Mpa-bar 0.35 - 3.5 0.35 - 3.5 0.35 - 3.5
Expansion Vessel Charge Pressure Mpa-bar 0.35 - 3.5 0.35 - 3.5 0.35 - 3.5
Expansion Valve Setting Mpa-bar 0.6 - 6.0 0.6 - 6.0 0.6 - 6.0
Maximum Primary Working Pressure Mpa-bar 0.3 - 3.0 0.3 - 3.0 0.3 - 3.0Opening Temperature of T&P Relief Valve °C 90 90 90
Opening Pressure of T&P Relief Valve Mpa-bar 1.0 - 10 1.0 - 10 1.0 - 10
PHYS
ICAL
Material Stainless Steel
Insulation CFC/HCFC free polyurethane foam
Height mm 1090 1474 2040
Diameter mm 550 550 550
Weight Net kg 31 41 60
POW
ER Power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Suggested Fuse Size A 16 16 16
Domestic Hot Water Tank £987 £1,151 £1,352
Retail Price £987 £1,151 £1,352
@amp_aircon | amp-air-conditioning 192
Appl
ied
& A
2W
Applied Products & Air to WaterEstia - Hydro Units - High Temperature
Hydro Unit HWS-P804XWHM3-E1 HWS-P804XWHT6-E1 HWS-P804XWHT6-E1
Remote Controller HWS-AMS11E HWS-AMS11E HWS-AMS11E
WAT
ER P
IPIN
G
Water Piping Maximum Length None None None
Water Piping Max. Height Difference m 7 7 7
Water Piping Minimum Flow Rate l/m 13+ 13+ 13+
Water Piping Max. Working Water Pres. Kpa 300 300 300
HEA
T EX
CHAN
GER Heat Exchanger Plate-type Heat Exchanger
Heat Exchanger Type Brazed Plate Brazed Plate Brazed Plate
Heat Exchanger Water Volume liters 0.67 0.67 0.67
Heat Exchanger Minimum Flow Rate l/m 13 13 13
PUM
P D
ETAI
LS
Circulating Pump Max Motor Output W 125 125 125
Circulating Pump Flow Rate l/m 22.9 22.9 22.9
Circulating Pump Type Non-Self suction centrifugal Pump
Water Pump Power Input W 48 48 48
Water Pump Delivery Head m 6.3 6.3 6.3
PHYS
ICAL
Unit Dimensions (H-W-D) mm 925 - 525 - 355 925 - 525 - 355 925 - 525 - 355
Weight kg 49 49 49
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”
Sound Pressure level dB(A) 27 27 27
OPE
RATI
NG
RAN
GE Expansion Vessel Volume Liters 12 12 12
Expansion Vessel Initial Pressure Mpa-Bar 0.1 - 1.0 0.1 - 1.0 0.1 - 1.0
Pressure Relief Valve Operating Pressure Mpa-Bar 0.3 - 3.0 0.3 - 3.0 0.3 - 3.0
Water Temperature Range Heating °C 20 - 60 20 - 60 20 - 60
POW
ER
Back up Heater Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50
Back up Heater Power - Max Current A 3.0 - 13 6.0 - 13 (13Ax2P) 9.0 - 13 (13Ax3P)
Hot Water Cylinder Heater power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Hot Water Cylinder Heater Max. Current A 12.0 12.0 12.0
Hydro Unit £2,791 £2,899 £2,998
Remote Controller £90 £90 £90
Retail Price £2,881 £2,989 £3,088
Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail
Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail
ampair.co.uk | 01707 378 670 | [email protected] 193
Appl
ied
& A
2W
Applied Products & Air to WaterEstia - Hydro Units - High Temperature
Hydro Unit HWS-1104XWHM3-E1 HWS-1104XWHT6-E1 HWS-1104XWHT9-E1
Remote Controller HWS-AMS11E HWS-AMS11E HWS-AMS11E
WAT
ER P
IPIN
G
Water Piping Maximum Length None None None
Water Piping Max. Height Difference m 7 7 7
Water Piping Minimum Flow Rate l/m 17.5+ 17.5+ 17.5+
Water Piping Max. Working Water Pres. Kpa 300 300 300
HEA
T EX
CHAN
GER Heat Exchanger Plate-type Heat Exchanger
Heat Exchanger Type Brazed Plate Brazed Plate Brazed Plate
Heat Exchanger Water Volume liters 1.18 1.18 1.18
Heat Exchanger Minimum Flow Rate l/m 17.5 17.5 17.5
PUM
P D
ETAI
LS
Circulating Pump Max Motor Output W 190 190 190
Circulating Pump Flow Rate l/m 32.1 32.1 32.1
Circulating Pump Type Non-Self suction centrifugal Pump
Water Pump Power Input W 87 87 87
Water Pump Delivery Head m 8.8 8.8 8.8
PHYS
ICAL
Unit Dimensions (H-W-D) mm 925 - 525 - 355 925 - 525 - 355 925 - 525 - 355
Weight kg 52 52 52
Pipe Sizes (Gas - Liquid) in 5/8” - 3/8” 5/8” - 3/8” 5/8” - 3/8”
Sound Pressure level dB(A) 29 29 29
OPE
RATI
NG
RAN
GE Expansion Vessel Volume Liters 12 12 12
Expansion Vessel Initial Pressure Mpa-Bar 0.1 - 1.0 0.1 - 1.0 0.1 - 1.0
Pressure Relief Valve Operating Pressure Mpa-Bar 0.3 - 3.0 0.3 - 3.0 0.3 - 3.0
Water Temperature Range Heating °C 20 - 60 20 - 60 20 - 60
POW
ER
Back up Heater Power Supply V-Ph-Hz 230 - 1 - 50 400 - 3 - 50 400 - 3 - 50
Back up Heater Power - Max Current A 3.0 - 13 6.0 - 13 (13Ax2P) 9.0 - 13 (13Ax3P)
Hot Water Cylinder Heater power Supply V-Ph-Hz 230 - 1 - 50 230 - 1 - 50 230 - 1 - 50
Hot Water Cylinder Heater Max. Current A 12.0 12.0 12.0
Hydro Unit £3,557 £3,667 £3,686
Remote Controller £90 £90 £90
Retail Price £3,647 £3,757 £3,776
Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail
Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail
Liam Stay - Integra
Richard Morley, External Technical Support at AMP
Appl
ied
& A
2W
@amp_aircon | amp-air-conditioning 194@amp_aircon | amp-air-conditioning 194
Steve Perham - JLR Maintenance
“Having worked with AMP since their formation in 1989 it goes without saying
that they are by far my preferred supplier. They continue to deliver the very best
service, support and expertise, my first choice for all my air conditioning needs”
Cont
rols
Controls & Accessories
ampair.co.uk | 01707 378 670 | [email protected] 195ampair.co.uk | 01707 378 670 | [email protected] 195
@amp_aircon | amp-air-conditioning 196
Cont
rols
Controls & AccessoriesWired & Wireless Remote Controllers
Wired Remote Controllers
RBC-AMT32E RBC-AMS41E
Standard RemoteController
Remote Controller With Built In 7 Day Time Clock
Full control including service functions
Standard controller but with fully programmable 7 day timer
£50 £66
RBC-AMS54E-ES RBC-AS41E
Lite-Vision Plus Remote Controller Simplifi ed Controller
Includes timer and back light display as well as power save
functions, multi-lingual
Ideal for hotel and base use applications (no service function
available)
£105 £70
Wireless Remote Controllers
RBC-AX32U(W)-E RBC-AX32UW(W)-E
Wireless RemoteController Kit - 4 Way
Cassette
Wireless RemoteController Kit - 2 Way
Cassette
Replacement corner panel with built in receiver and remote controller for RAV and VRF
standard cassettes
Infra red remote controller kit for VRF 2 way cassettes
£151 £179
RBC-AX33CE TCB-AX32E2
Wireless RemoteController Kit - Ceiling Suspended (7 Series)
Wireless RemoteController Kit - Others
Infra red kit for RAV and VRF ceiling suspended units
Infra red remote controller kit for RAV and VRF ducted, fl oor standing models and compact
cassettes
£166 £214
ampair.co.uk | 01707 378 670 | [email protected] 197
Cont
rols
Controls & AccessoriesCentralised Remote Controllers
Standard Centralised Controllers
TCB-CC163TLE2 TCB-SC642TLE2
On - Off Controller Central Remote Controller
Up to 16 indoor units can be turned on/off individually or
collectively. run & fault output
A fully programmable central controller for up to 64 indoor units
£741 £776
TCB-EXS21TLE
Schedule Remote Controller
Connects to TCB-SC642TLE or compliant manager to provides
weekly time clock (7 day 3 on / off per day)
£271
Touch Screen Centralised Controller
Built in Web BrowserBack-up and RestoreMulti-language preferenceAlarm SettingsUnit setup, status and inhibitProgrammable time and date eventsMax 64 Indoor Units/Groups and 16 Outdoor systems can be connectedTCB-PCNT30TLE2 Network adaptor required for connection of DI/SDI to provide TCC Link Connection
RBC-TBPTS
Smart Touch Controller
Touch screen controller for up to 64 indoor units, including built in
web browser
£2,258
@amp_aircon | amp-air-conditioning 198
Cont
rols
Controls & AccessoriesCentralised Remote Controllers - PC Based
Central controller with PC connection - by connecting a PC via the LAN port of the Smart Manager, VRF & RAV* indoor units can becontrolled via internet explorer
Between 1 to 64 indoor
units
Between 65 to 128 in-
doors units
Between 129 to 192 indoor
units
Between 193 to 256 indoor
units
Item Description RetailPrice
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
BMS-SM1280E-TLE
Smart manager, 128 indoor units, 64 max. per circuit £2,000 1 £2,000 1 £2,000 2 £4,000 2 £4,000
AMP-ECX crossed Ethernet cable for PC connection £10 1 £10 1 £10 2 £20 2 £20
Total solution retail price £2,010 £2,010 £4,020 £4,020
optional items
*TCB-PCNT30TLE Interface PCB required by each RAV split system connected to above controls system £78
COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE £650
BMS-IFDD03E Digital input / output interface to allow control & monitoring of other plant, 8 digital inputs & 4 digital outputs £921
BMS-IFWH5E Energy monitoring relay interface, allows up to 8 power meters to be connected, see RBC-EM1-PE below £440
RBC-EM1-PE Power meter, 1 required per refrigeration systems, see BMS-IFWH5E above and EM1-PANEL below £1,149
EM1-PANEL Housing and wiring for RBC-EM1-PE, 1 required per refrigeration system NETT PRICE £1,208
Notes: • Smart manager time clock schedule set via pc on commissioning • for installations with more than 256 indoor units please contact AMP for pricing • indoor units connected to the same outdoor unit can not be connected to 2 different circuits, as such this may reduce the maximum capacity
Compliant / Smart Mangers
• Control up to 128 indoor units on 2 separate communication lines (64 indoors & 16 outdoors per net-work)
• Can be connected to all Toshiba DI, SDI and VRF indoor units (split systems require TCB-PCNT-30TLE2 interface pcb, adapter built into KRT wall mounts)
• Control via pc (web access) (BMS-SM1280ETLE only) and ability to provide energy monitoring; this will require indoor units to be manually addressed and amp will need to attend site to commission
• If time clock is required amp must attend site to enable this feature
BMS-CM1280TLE BMS-SM1280ETLE
Compliant Manager Standard Version
Smart Manager with Data Analyser
Enables full control of up to 128 indoor units (2 x 64 control
circuits)
for control of up to 128 indoors, inc remote access via web browser
£854 £2,000
ampair.co.uk | 01707 378 670 | [email protected] 199
Cont
rols
Controls & AccessoriesCentralised Remote Controllers - PC Based
Windows Control Package - Interactive Intelligence
PC based windows control package - allows Toshiba VRF & RAV* indoor units to be controlled and monitored via an on site PC (field supplied)
Between 1 to 64 indoor
units
Between 65 to 128 indoor
units
Between 129 to 192 indoor
units
Between 193 to 256 indoor
units
Item Description RetailPrice
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
RBC-WP1-PE windows control package, max. 1024 indoors £2,100 1 £2,100 1 £2,100 1 £2,100 1 £2,100
TCB-IFLN642TLE LON gateway, maximum 64 indoor units £1,100 1 £1,100 2 £2,200 3 £3,300 4 £4,400
Total solution retail price £3,200 £4,300 £5,400 £6,500
optional items
*TCB-PCNT30TLE Interface PCB required by each RAV split system connected to above controls system £78
COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE £650
RBC-IK1-PE Internet kit to allow on site PC to be controlled via a remote location, 1 required per RBC-WP1-PE £1,687
RBC-DI1-PE Digital input / output module to allow control of other plant via RBC-WP1-PE, 8 digital inputs & 8 digital outputs £349
RBC-EM1-PE Power meter for calculating the running costs of individual indoor units, 1 required per refrigeration systems, see EM1-PANEL below
£1,149
EM1-PANEL Housing and wiring for RBC-EM1-PE, 1 required per refrigeration system NETT PRICE £1,208
Notes: Please contact amp for PC specification • for installations with more than 256 indoor units please contact AMP for pricing • indoor units connected to the same outdoor unit can not be connected to 2 different circuits / LON interfaces, as such this may reduce the maximum capacity of each circuit / LON interface
LONworks Gateway
Allows Toshiba VRF & RAV* indoor units to be controlled and monitored by LONworks BMS
Between 1 to 64 indoor
units
Between 65 to 128 indoor
units
Between 129 to 192 indoor
units
Between 193 to 256 indoor
units
Item Description RetailPrice
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
TCB-IFLN642TLE LON gateway, maximum 64 indoor units £1,100 1 £1,100 2 £2,200 3 £3,300 4 £4,400
Total solution retail price £1,100 £2,200 £3,300 £4,400
optional items
*TCB-PCNT30TLE Interface PCB required by each RAV split system connected to above controls system £78
COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE £650
@amp_aircon | amp-air-conditioning 200
Cont
rols
Controls & AccessoriesBMS Interfaces
Modbus Blackpear BMS Interfaces
Modbus Interface - Allows Toshiba VRF & RAV* indoor units to be controlled & monitored via Modbus RTU via RS232 / RS485 and Modbus / TCP
Between 1 to 64 indoor
units
Between 65 to 128 indoor
units
Between 129 to 192 indoor
units
Between 193 to 256 indoor
units
Item Description RetailPrice
Qty.Req
TotalRetail
Qty.Req
TotalRetail
Qty.Req
TotalRetail
Qty.Req
TotalRetail
RBC-BPM1 Modbus Interface - 64 indoor units max £3,513 1 £3,513 2 £7,026 3 £10,539 4 £14,052
Total solution retail price £3,513 £7,026 £10,539 £14,052
optional items
*TCB-PCNT30TLE Interface PCB required by each RAV split system connected to above controls system £78
COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE £650
Trend Blackpear BMS Interfaces
Trend Interface - Allows Toshiba VRF & RAV* indoor units to be controlled & monitored via Trend via ethernet (also requires IQ3/4outstation with spare memory, by others
Between 1 to 64 indoor
units
Between 65 to 128 indoor
units
Between 129 to 192 indoor
units
Between 193 to 256 indoor
units
Item Description RetailPrice
Qty.Req
TotalRetail
Qty.Req
TotalRetail
Qty.Req
TotalRetail
Qty.Req
TotalRetail
RBC-BPT1 Trend Interface - 64 indoor units max £3,513 1 £3,513 2 £7,026 3 £10,539 4 £14,052
Total solution retail price £3,513 £7,026 £10,539 £14,052
optional items
*TCB-PCNT30TLE Interface PCB required by each RAV split system connected to above controls system £78
COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE £650
BACnet Blackpear BMS Interfaces
BACnet Interface - Allows Toshiba VRF & RAV* indoor units to be controlled & monitored via BACnet / IP
Between 1 to 64 indoor
units
Between 65 to 128 indoor
units
Between 129 to 192 indoor
units
Between 193 to 256 indoor
units
Item Description RetailPrice
Qty.Req
TotalRetail
Qty.Req
TotalRetail
Qty.Req
TotalRetail
Qty.Req
TotalRetail
RBC-BPB1 Modbus Interface - 64 indoor units max £3,313 1 £3,513 2 £7,026 3 £10,539 4 £14,052
Total solution retail price £3,513 £7,026 £10,539 £14,052
optional items
*TCB-PCNT30TLE Interface PCB required by each RAV split system connected to above controls system £78
COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE £650
ampair.co.uk | 01707 378 670 | [email protected] 201
Cont
rols
Controls & AccessoriesBMS Interfaces
BACnet Gateway
BACnet Interface - Allows Toshiba VRF & RAV* indoor units to be controlled & monitored by BACnet over IP based BMS
Between 1 to 64 indoor
units
Between 65 to 128 indoor
units
Between 129 to 192 indoor
units
Between 193 to 256 indoor
units
Item Description RetailPrice
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
Qty.Req.
TotalRetail
BMS-LSV9E intelligent server for up to 128 indoor unit max. £3,597 1 £3,597 1 £3,597 2 £7,194 2 £7,194
BMS-STBN10E intelligent server software (1 per intelligent server) £1,739 1 £1,739 1 £1,739 2 £3,478 2 £3,478
BMS-IFLSV4E TCS-Net relay interface £672 1 £672 2 £1,344 3 £2,016 4 £2,688
Total solution retail price £6,008 £6,680 £12,688 £13,360
optional items
*TCB-PCNT30TLE Interface PCB required by each RAV split system connected to above controls system £78
COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE £650
Intesis Home Interfaces
RBC-TO-RC-WIFI-1 RBC-IS-IR-WIFI-1
INTESIS Home Interface Infrared WiFi Adapter
Suitable for RAV and VRF Units. Forcompatibility list visit
intesishome.com/compatibility
For compatibility list visit intesishome.com/compatibility
£271 £208
Black Pear Interface
@amp_aircon | amp-air-conditioning 202
Cont
rols
Controls & AccessoriesIndoor Wiring Adapters
Part Number Function Plug Description RAV VRF Retail Price
RBC-SMFI Fan output CN32Provides control of auxiliary ventilation fan through local remote
Yes Yes £54
AMP-TCH Operation output CN60Operation status output for cooling, heating, fan, defrost and thermo on, 12V DC
Yes Yes £16
RBC-SMIM2 Operation output CN60Operation status output for cooling, heating, fan, volt free
Yes Yes £82
RBC-SMT1 Remote on / off On re-mote
An external input on RBC-AMT32-E remote controller for remote on / off, volt free
Yes Yes £9
AMP-TRFOperation input / output (12VDC output), see follow-ing page for details
CN61
A range of interface for on/off, lock and run / fault, see details of each interface for functionality
Yes Yes £16
AMP-TRFVF Operation input / output (volt free output) Yes Yes £68
AMP-TRFVF+Operation input / output (volt free output and 12VDC on/off)
Yes Yes £110
RBC-SMCN61 Interface lead for on / off & unit remote controller lock Yes Yes £11
RBC-SMIM3 Indicator for lock out fault and unit run, volt free Yes Yes £76
TCB-IFCB-4E Remote location on / off control box Yes Yes £229
AMP-L30I Outside error input CN80Input to generate L30 stop-ping fault code, stop system and brings up fault code
Yes Yes TBC
Remote Sensor
TCB-TC41LE
Remote Sensor
Remote return air sensor
£64
Indoor Unit Wiring Adapters
ampair.co.uk | 01707 378 670 | [email protected] 203
Cont
rols
Controls & AccessoriesOutdoor Wiring Adapters
Part Number Function Plug Description RAV VRF Retail Price
TCB-PCDM4E Power peak cut control CN513
Restricts the upper limit capacity of the outdoor unit, reducing peak energy usage
No Yes £81
TCB-PCM04E Snow fall fan control CN509 Input to run outdoor fan periodically to
clear outdoor unit of snow No Yes £63
TCB-PCM04E External mas-ter on/off CN512 Input to outdoor unit to switch entire
system on / off No Yes £63
TCB-PC1N4E Error operation output
CN511/
CN513(mini)
Run and fault output (when more than 1 indoor unit has a fault) No Yes £89
TCB-PCM04E Night oper-ation CN508 Input to outdoor unit to reduce sound
level, also reduce max. system capacity No Yes £63
TCB-PCM04E Operationmode selection CN510
Input to outdoor unit to either force (8HP+) or set priority (4-6HP) to either cooling or heating
No Yes £63
TCB-PCOS1E2 Night oper-ation
CN300/
CN704& 610
Input to outdoor unit to reduce sound level, also reduce max. system capacity (DI 2 and 3 series, SDI 404 & 564)
Yes* No £149
TCB-KBOS1E Night oper-ation
CN300CN704CN610
Input to outdoor unit to reduce sound level, also reduce max. system capac-ity (DI & SDI 4 series, not 404 or 564 models)
Yes* No £27
*RAV DI, some of series 3 only, SDI some of series 4 only
AMP-TRF
Outdoor Unit Wiring Adapters
@amp_aircon | amp-air-conditioning 204
Cont
rols
Controls & AccessoriesLeak Detection & Containment
Toshiba has a solution to help you gain BREEAM credits and more.
In-line with the building services industries continued pro-active eff orts to reduce CO2 emissions and to meet targets to build greener buildings, Toshiba have developed a market leading Leak Detection and Pump-down system that enables BREEAM credits to be claimed on a building using both Split DX and VRF systems. In addition, our solution also provides a means to demonstrate compliance with the current EN378 2008 standard where refrigerant concentration levels may exceed practical safety limits of 0.44kg/m3.
Leak Detection Set-Up
The leak detection system works via sensors which detect changes in the refrigerant pressure which signifi es a decrease in the levels of refrigerant gas. This triggers and audible and visual alarm and shuts down the device. In the case of the RBC-RD6 unit, the outdoor unit, a cooling mode will be enabled and pump-down will commence.
All leak detection options can be used on Digital Inverter, Super Digital Inverter, Large Capacity Digital Inverter, MiNi SMMS, SMMSe and SHRMi Units.
Where DI, SDI and LCDI units are selected the contractor will need to insert a Schader access port into the common suction line, before this can be carried out the refrigerant from the outdoor unit would need to be removed. This on site modifi cation is required to enable the pump-down solutions to work with these units.
ampair.co.uk | 01707 378 670 | [email protected] 205
Cont
rols
Controls & AccessoriesLeak Detection & Containment
Toshiba offer a range of sophisticated refrigerant monitoring, leak detection and containment systems. Below is a brief overview of the available items, please contact Amp for complete system configuration and pricing.
RBC-RD3 RBC-RD6 RBC-RD7
Leak Detection Room Sensor System Pump Down Interface Unit Isolation
The recessed room sensor is triggered if the concentration of R410A refrigerant exceeds the
practical safety limit of 0.44kg / m3 as stated in BSEN378 2012. The sensor
raises an audible and visual alarm within the bedroom and also via an L30 fault alarm this can transmit an indication alarm at the Toshiba WP1
software control loaded onto the reception office PC.
The RBC-RD6 enables both a major or gradual refrigerant leak to be identified and the activation of a
system pump - down to be triggered. The solution includes all isolation valves and central control panel.
In conjunction with the RBC-RD3 room sensor, via the RBC-RD7
Toshiba are able to provide a means to isolate an individual bedroom or occupied space without the need to fully shut down the air conditioning
system.
£444 £5,992 TBC
RBC-RP1 RBC-RI1 RBC-AIP1
Repeater Panel Complete With Battery Back Up
Room Indicator (legrand Graphite)
Remote Indication Alarm - For up to 8 x RBC-RD6 / RBC-RP1
panels inc. RBC-DI1
The RBC-RP1 repeater panel is designed to work in conjunction with
the Toshiba RBC-RD6 pump down panel.
Room indicator offers a visual and audible alarm if a leak is detected and has an integrated button to deactivate. for use with RBC-RP1
Toshiba provide a means of identifying that there has been a leak on the system in the event of the PC being turned off. This panel enables a remote alarm to be raised in the
event of the RD6 pump-down being activated
£1,437 £80 £1,663
RBC-AIP2 RBC-AIP3 RBC-AIP4
Remote Indication Alarm and Remote reset - For up to 4 x RBC-RD6 panels inc. RBC-DI
Alarm Indication Remote Alarm Indication
Toshiba provide a means of identifying that there has been a leak on the system in the event of the PC being turned off. This panel enables a remote alarm to be raised in the
event of the RD6 pump-down being activated
If the PC running the RBC-WP1 software and monitoring RBC-RD3’s
should shut down or lose power. The RBC-AIP3, located within 3m of the
desktop PC can monitor all potential failures and is fully USB compliant
with a battery backup system.
Remote alarm indication is provided by the RBC-AIP4 that can be up to 100m away from the main panel.
This means an alarm can be remotely indicated in the largest buildings.
£2,727 TBC TBC
@amp_aircon | amp-air-conditioning 206
Cont
rols
Controls & AccessoriesBrackets, Trays, Cages & Other Accessories
CBR2-S CBR2-M CBR2-L CBR1-XL
Small OutdoorUnit Bracket
Medium OutdoorUnit Bracket
Large OutdoorUnit Bracket
Extra LargeOutdoor
Unit Bracket
Max load - 60KG
Max load - 90KGCrossbar - 900mmUpright - 500mm
Support arm - 500mm
Max load - 140KGCrossbar - 1100mm
Upright - 550mmSupport arm - 540mm
Max load - 250KGCrossbar - n/a
Upright - 550mmSupport arm - 700mm
£23 £32 £36 £55
CCTM-800 CCTM-1100 CCTM-1400 CG-BPS CG-BPM
Small Heavy DutyMetal Drain Tray
Large Heavy DutyMetal Drain Tray
Large Heavy DutyMetal Drain Tray
Base Panel For HighLevel Cage Installation
Base Panel For HighLevel Cage Installation
L800 X W400mm L1100 X W400mm L1400 X W400mm For CG-SFor CG-M, CG-L and
CG-XL
£53 £58 £64 £41 £45
CG-S CG-M CG-L CG-XL
SmallCondenser Cage
MediumCondenser Cage
LargeCondenser Cage
Extra LargeCondenser Cage
External dimensions:H750 X W1050 X
D460mmInternal dimensions:
H720 X W1020 X D450mm
Weight: 18kg
External dimensions:H1150 X W1150 X
D650mmInternal dimensions:
H1120 X W1120 X D640mm
Weight: 30kg
External dimensions:H1450 X W1150 X
D650mmInternal dimensions:
H1420 X W1120 X D640mm
Weight: 33kg
External dimensions:H1800 X W1150 X
D650mmInternal dimensions:
H1770 X W1120 X D640mm
Weight: 44kg
£189 £272 £328 £468
CMB-450 CMB-1000 MBEC
450mm Outdoor Unit Mounting
Block
1000mm Outdoor Unit Mounting
BlockEnd Caps
Price Per Unit Price Per Unit Price Per Unit
£4 £9 £2
Net Prices.
ampair.co.uk | 01707 378 670 | [email protected] 207
Rew
ards
ampair.co.uk | 01707 378 670 | [email protected] 207
Toshiba Rewards
Rew
ards
@amp_aircon | amp-air-conditioning 208
Rew
ards
Toshiba RewardsIntroduction
Installer Network
Toshiba recognises the contribution that its network of installers makes towards our continued success story. In-line with their vision statement they have created a rewards incentive programme that further enhances the benefits available to our loyal customers.
Toshiba installers can continue to exchange loyalty points accumulated for purchasing Toshiba air conditioning products and redeem them for LOVE2SHOP gift cards, Toshiba air conditioning products or trade installation tools (see pages 210 - 211).
As an additional bonus they now offer a joint marketing initiative, as well as the clothing allowance for all members.
Qualifying Conditions
» To qualify for the rewards incentive all members must register with Toshiba Carrier UK Limited or with AMP Air Conditioning Limited.
» Only one account holder per company can register as a member.» Points are accumulated on paid invoices of Toshiba air conditioning equipment.» Sales channels through Toshiba Direct, Toshiba Distributor, Toshiba Wholesaler or Toshiba Approved
Re-seller (please refer to Toshiba web site for supplier details)» No minimum turnover.» Customer must adhere to F-Gas regulations and be Refcom registered (or equivalent) and be fully
compliant (copy of current Certificate required)» Please speak to your sales person who will be happy to assist with your registration details.
Every £40 net of invoiced purchases equates to 1 point
Exchange rewards points for…
» Love2Shop gift card» European and Worldwide holidays with Love2Travel» Toshiba air conditioning units and accessories» Trade installation products» Marketing support
ampair.co.uk | 01707 378 670 | [email protected] 209
Rew
ards
Toshiba RewardsWarranty
Rewards Enhanced Warranty
In addition to earning rewards points, by simply registering and being accepted onto the scheme you will automatically be entitled to an enhanced 5 year warranty on all future purchase of Toshiba equipment.
This can be further enhanced by attending Toshiba training courses, as detailed below.
T5 Registered Installer
» Refcom – F-gas qualifi cation» 5 Years warranty» No minimum spend» Generous warranty labour allowances
T7 Enhanced Warranty Partner
» Refcom – Fgas qualifi cation» Completed the following Toshiba training courses
» Digital Inverter / Super Digital Inverter» VRF» Controls
» 7 Years warranty» No minimum spend» Enhanced warranty labour allowances» Website processing for commissioning data and maintenance records
T7 Approved Partner
» Refcom – F-gas qualifi cation» Completed the following Toshiba training courses
» Digital Inverter / Super Digital Inverter» VRF» Controls
» 7 Years warranty» No minimum spend» Generous warranty labour allowances
@amp_aircon | amp-air-conditioning 210
Rew
ards
Toshiba RewardsRewards Gift Cards
Exchange rewards points for Love2Shop gift cards
Exchange Love2Shop gift card for other Love2Shop promotions:
» Love2Shop MobileNew purchase of mobile phones, tablets and SIM cards using Love2Shop Gift Cards visit www.l2s-mobile.co.uk
» Digital gift codes exchange online for goods or vouchers:Amazon, B&Q, Starbucks, iTunes, Debenhams, John Lewis and many more
» Love2Shop HolidaysSpend your gift card on a holiday including package holidays, UK breaks, theme parks, flights, cruises, hotels with airport
parking or simply spend your gift card on a holiday call 0845 077 4444
» Love2Shop ExperiencesAccepted at a fantastic range of attractions, including Alton Towers Resort and Gulliver’s World Theme Parks
Can be used at www.love2shopexperiences.co.uk to book hundreds of unique experiences.
Activities available include relaxing spa
Value Points£100 200
£150 290
£200 380
£250 470
£300 560
£350 650
£400 740
£450 830
£500 920
£550 1,000
The points accumulated for paid purchases of Toshiba air conditioning units and air conditioning accessories can be exchanged for Love2Shop gift cards including European and Worldwide holidays with Love2Travel:
Redemption Values for Love2Shop
ampair.co.uk | 01707 378 670 | [email protected] 211
Rew
ards
Toshiba RewardsToshiba Units & Installation Tools
Exchange rewards points for Toshiba air conditioning equipment and accessories
The points accumulated for paid purchases of Toshiba air conditioning units and air conditioning accessories can be exchanged for more air conditioning units and accessories. Redemption value is equal to net price.
Illustrative example of redemption value at net price.
RAV-SM566KRT-E» Retail Price £391.00» Contractor discount 42% £164.41» Net Price £226.59» Points required 227
RAV-SM564ATP-E» Retail Price £840.00» Contractor discount 42% £352.80» Net Price £487.20» Points required 488
Exchange rewards points for air conditioning trade installation tools
The points accumulated for paid purchases of Toshiba air conditioning units and air conditioning accessories can be exchanged for installation tools listed below:
Item Points RequiredPromax RG5410 Extreme Recovery unit 110V 1170
Mastercool 99661-EU Digital Manifold 2-Way 744
Hydraulic Crossbow Tube Bender 3/8 - 7/8 tube 670
PRO100 new Style Tube Expander Set (up to 1 1/8) 338
BM4-3-DS-R410A-SRW Manifold Kit 273
Xp-1 Electronic Leak Detector 448
ACCU Charge Electronic Scale 98200-A 193
Clarke TL-2 3.85M Telescopic Ladder 222
CT808F Eccentric Flaring Tool (1/4" - 3/4") 58
@amp_aircon | amp-air-conditioning 212
Rew
ards
Toshiba RewardsMarketing Contribution & Project Support
Rewards Marketing Contribution
The points accumulated for paid purchases of Toshiba air conditioning units and air conditioning accessories can be exchanged for marketing support.
» Trade Clothing» Sign writing of vehicles» Corporate Days» Industry Dinners» Sponsorship» Sports Events» Marketing support tools
Toshiba will provide a 50 / 50 contribution towards marketing» Illustrative example Golf day accumulated value £1,000 + TCUK £1,000 = £2,000» Limited to a maximum of 1% of member’s annual purchase value» Subject to approval by Toshiba Carrier UK Limited.» Marketing claim(s) must be approved in advance by Toshiba Carrier UK Limited and conform to United Technologies Corporation guidelines and agreements (available on request)
Retrospective Adjustment Credit (RAC) for Registered Specifications
A Registered Member on successfully achieving a consultant’s full specification for Toshiba equipment on a specified project may register that project with the Toshiba Projects Department to obtain and allocate a Toshiba Quote Number (TQN). Proof of the consultant’s full specification document must subsequently be submitted either by hard copy or electronic form naming the specifying Registered Member. In the event that more than one Registered Member claims to have specified the project, the project will be registered to the Registered Member supplying the earliest dated tender document naming the Registered Member as the Registered Installer.
In the event that the specifying Registered Member’s tender bid is unsuccessful, providing that the successful contractor purchases Toshiba equipment for the specified project registered on the TQN from Toshiba either direct or through our registered Toshiba Distributor, Toshiba Wholesaler or Toshiba Approved Re-seller, Toshiba agrees to award the Registered Member who successfully registered the project with a Retrospective Adjustment Credit (RAC) to the value of 3% of the retail price of the actual equipment supplied for the specified project as published in the latest Retail Price List.
For full terms and conditions please contact AMP
ampair.co.uk | 01707 378 670 | [email protected] 213
Rew
ards
Toshiba RewardsApplication
Rewards Incentive Application Form (illustration)
For further information and to apply please contact AMP Air Conditioning
@amp_aircon | amp-air-conditioning 214@amp_aircon | amp-air-conditioning 214
“AMP are one of our top suppliers; they are always very helpful and flexible with
excellent back up and support. Overall they provide an excellent service.”
Liam Stay - Integra
Photo: Zuzzana Reed, Finance Manager at AMPRew
ards
ampair.co.uk | 01707 378 670 | [email protected] 215
Refe
renc
e/Fa
ults
ampair.co.uk | 01707 378 670 | [email protected] 215
Refe
renc
e/Fa
ults
Reference / Faults Codes
@amp_aircon | amp-air-conditioning 216
Refe
renc
e/Fa
ults
ReferenceRAV Fault Codes
@amp_aircon | amp-air-conditioning 216
Refe
renc
e/Fa
ults
Fault codes are displayed directly on wired remote controller – to access the service history: press CHECK and SET for 4 seconds
» press CHECK and SET for 4 seconds» scroll through stored codes using the TEMP set buttons» press CHECK to cancel service history» press CLEAR to delete codes » up to 4 Codes can be stored
Code Description
E01 Controller (local or network) receives no communication from a master indoor unit- could include that master is turned off. Also check that there is a master controller
E02 Local controller failure (unable to transmit)
E03 Master indoor unit receives no data to A-B. Often appears as an E01 fault code
E04 Indoor unit (except twin slave) receives no communication from outdoor unit; can include klixon on 560 Digital Inverter split system
E08 Duplicated indoor address
E09 2 local controller on a group – both configured as masters
E10 Indoor PCB failure
E18 Communication failure between master indoor unit and slave
F01 Indoor TCJ sensor error
F02 Indoor TC2 sensor error
F04 TD1 sensor error
F06 TE1 sensor error
F08 TO sensor error
F10 Indoor TA sensor error
F29 Indoor PCB failure
H01 Inverter compressor over current detected
H02 Master outdoor unit over current detected shortly after start up
H03 Current detected on master outdoor unit whilst idle
ampair.co.uk | 01707 378 670 | [email protected] 217
Refe
renc
e/Fa
ults
ReferenceRAV Fault Codes
ampair.co.uk | 01707 378 670 | [email protected] 217
Refe
renc
e/Fa
ults
Code Description
H06 Low pressure detected by Ps sensor (0.02Mpa)
L03 Duplicated master indoor units in a group
L07 Indoor in a group previously addressed as a single unit – check addressing
L08 Indoor address not set
L09 Indoor unit capacity not set
L29 IPDU error (number of detected IPDU units is reduced)
L30 Input on CN80 circuit for 1 minute
L31 Outdoor PCB error
P01 Indoor fan motor error
P03 High discharge temperature (TD1 exceeded 115°C)
P04 High pressure switch activated (Detected by high TE temp on Digital Inverter)
P07 Heat sink overheat
P10 Float switch activated
P12 Indoor fan motor error – detected by feedback circuit
P19 Wrong change in temperature (4 way valve error)
P22 Outdoor fan IPDU error
P26 Giant Transistor short circuit comp or inverter error
P29 Compressor error detected by feedback circuit
P31 Indoor PCB error
Error by TCC-Link central controller
Code Description
C05 Sending error in TCC-Link central control device
C06 Receiving error in TCC-Link central control device
C12 Batch alarm for general purpose equipment control interface
P30 Group control follower unit error/duplicated central control addresses
@amp_aircon | amp-air-conditioning 218
Refe
renc
e/Fa
ults
ReferenceVRF Fault Codes
@amp_aircon | amp-air-conditioning 218
Refe
renc
e/Fa
ults
Remote Outdoor 7 segment display Check code Device
E01 --- Communication error between indoor unit and remote controller (Detected at remote controller) remote controller
E02 --- --- Sending error of remote controller remote controller
E03 --- --- Communication error between indoor unit and remote controller (Detected indoor) Indoor
E04 --- Communication circuit error between indoor and outdoor units (Detected indoor) Indoor
E06 E06 No. of indoor units in which sensor has been normally received Decrease of No. of indoor units I/F
--- E07 --- Communication circuit error of indoor and outdoor units (Detected outdoor) I/F
E08 E08 Duplicated indoor address Duplicated indoor address Indoor / I/F
E09 --- --- Duplicated master remote controllers remote controller
E10 --- --- communication error in indoor PCB Indoor
E12 E1201: Indoor / Outdoor communication
Automatic address start error I/F02: communication between outdoor units
E15 E15 --- No indoor automatic address I/F
E16 E1600: Over capacity
No. of indoor units / Over capacity I/F01: No. of connected units
E18 --- --- Communication error between indoor header and follow units Indoor
E19 E1900: No. header units
Outdoor header units quantity error I/F02: 2 or more header units
E20 E2001: Outdoor of other line connected
Other line connected during automatic address I/F02: indoor of other line connected
E23 E23 --- Sending error in communication between outdoor units I/F
E25 E25 --- Duplicated follower outdoor unit addresses I/F
E26 E26 No. of outdoor units which receive signal normally Decrease of No. of connected outdoor units I/F
E28 E28 Detected outdoor unit number Outdoor follower error I/F
E31 E31
01: IPDU 1 error
IPDU communication error I/F
02: IPDU 2 error
03: IPDU 1, 2 error
04: Fan IPDU error
05: IPDU 1 + Fan IPDU error
06: IPDU 2 + Fan IPDU error
07: All IPDU error
ampair.co.uk | 01707 378 670 | [email protected] 219
Refe
renc
e/Fa
ults
ReferenceVRF Fault Codes
ampair.co.uk | 01707 378 670 | [email protected] 219
Refe
renc
e/Fa
ults
Remote Outdoor 7 segment display Check code Device
F01 --- --- indoor TCJ (coil) sensor error Indoor
F02 --- --- indoor TC2 (coil) sensor error Indoor
F03 --- --- indoor TC1 (coil) sensor error Indoor
F04 F04 --- outdoor TD1 (discharge) sensor error I/F
F05 F05 --- outdoor TD2 (discharge) sensor error I/F
F06 F06 --- outdoor TE1 () sensor error I/F
F07 F07 --- outdoor TL () sensor error I/F
F08 F08 --- outdoor T0 (ambient) sensor error I/F
F10 --- --- Indoor TA (Return Air) sensor error Indoor
F12 F12 --- Outdoor TS1 (Suction) sensor error I/F
F13 F1301: Compressor 1 side
Outdoor TH (IPDU) sensor error IPDU02: Compressor 2 side
F15 F15 --- Outdoor temp. sensors misconnected (TE, TL) I/F
F16 F16 --- Outdoor pressure sensors misconnected (pd, Ps) I/F
F23 F23 --- Outdoor Ps (pressure) sensor error I/F
F24 F24 --- Outdoor Pd (pressure) sensor error I/F
F29 --- --- Indoor other error Indoor
F31 F31 --- Outdoor EPROM error I/F
H01 H0101: Compressor 1 side
Compressor breakdown IPDU02: Compressor 2 side
H02 H0201: Compressor 1 side
Magnetic switch (contactor) error Over current relay opera-tion Compressor error (Lock)
MG-SW over cur-rent relay IPDU
02: Compressor 2 side
H03 H0301: Compressor 1 side
Current detection circuit system error IPDU02: Compressor 2 side
H04 H04 --- Compressor 1 case thermo operation I/F
H06 H06 --- Low pressure protection operation I/F
H07 H07 --- Low oil level protection detected I/F
@amp_aircon | amp-air-conditioning 220
Refe
renc
e/Fa
ults
ReferenceVRF Fault Codes
@amp_aircon | amp-air-conditioning 220
Refe
renc
e/Fa
ults
Remote Outdoor 7 segment display Check code Device
H08 H08
01: TK1 sensor error
Oil level detection temperature sensor error I/F02: TK2 sensor error
03: TK3 sensor error
04: TK4 sensor error
H14 H14 --- Compressor 2 case thermo operation I/F
H16 H16
01: TK1 oil circuit system error
Oil level detection circuit error, Magnetic switch (contactor) error, Over current relay operation
MG-SW over current relay
02: TK2 oil circuit system error
03: TK3 oil circuit system error
04: TK4 oil circuit system error
L03 L03 --- Duplicated indoor header units Indoor
L04 L04 --- Duplicated outdoor line address I/F
L05 L05 --- Duplicated indoor units with priority (Displayed on indoor unit with priority) I/F
L06 L06 No. of indoor units with priority Duplicated indoor units with priority (Displayed in unit other than indoor unit with priority) I/F
L07 --- --- Group line in individual indoor unit Indoor
L08 L08 --- Indoor group / address unset Indoor
L09 --- --- Indoor capacity unset Indoor
L10 L10 --- Outdoor capacity unset I/F
L17 L17 --- Inconsistency error of outdoor units I/F
L18 L18 --- FS unit error FS unit
L20 --- --- Duplicated central controller addresses AI-NET
L28 L28 --- No. of connected outdoor units overcapacity I/F
L29 L29
01: IPDU1 error
No. of IPDU error I/F
02: IPDU2 error
03: IPDU3 error
04: Fan IPDU error
05: IPDU1 + Fan IPDU error
06: IPDU2 + Fan IPDU error
07: All IPDU error
ampair.co.uk | 01707 378 670 | [email protected] 221
Refe
renc
e/Fa
ults
ReferenceVRF Fault Codes
ampair.co.uk | 01707 378 670 | [email protected] 221
Refe
renc
e/Fa
ults
Remote Outdoor 7 segment display Check code Device
L30 L30 Detected indoor address Auxiliary interlock in indoor unit Indoor
--- L31 --- IC error I/F
P01 --- --- Indoor fan motor error Indoor
P03 P03 --- Discharge temperature TD1 error I/F
P04 P0401: Compressor 1 side
High pressure switch detection error IPDU02; Compressor 2 side
P05 P0501: Phase-missing detection
Phase-missing detection / Phase order error I/F02: Phase order error
P07 P0701: Compressor 1 side
Heat sink overheat error IPDU I/F02: Compressor 2 side
P10 P10 Detected indoor address Indoor overflow error Indoor
P12 --- --- Indoor fan motor error Indoor
P13 P13 --- Outdoor liquid back detection error I/F
P15 P1501: TS condition
Gas leak detection I/F02: TD condition
P17 P17 --- Discharge temperature TD2 error I/F
P19 P19 Detected outdoor unit number 4-Way valve inverse error I/F
P20 P20 --- High pressure protection operation I/F
P22 P22
0_:IGBT short
Alt Outdoor fan IPDU error fan IPDU
1_: Fan motor position circuit error
3_: Fan motor error
C_; TH sensor temp. error (overheat)
D_: TH sensor error
E_: Vdc output error
P26 P2601: Compressor 1 side
G-TR short circuit protection error IPDU02: Compressor 2 side
P29 P2901: Compressor 1 side
Compressor position detective circuit system error IPDU02: Compressor 2 side
P31 --- --- Other indoor unit error (Group follower unit error) Indoor
@amp_aircon | amp-air-conditioning 222
Refe
renc
e/Fa
ults
ReferenceReplacement Technology Tables
@amp_aircon | amp-air-conditioning 222
Refe
renc
e/Fa
ults
Use the tables on this page to determine if it is possible to reuse existing pipework for a given outdoor unit. The maximum pipe run, pre-charged length and any reduction in cooling capacity will depend on the pipe sizes used.
Outdoor Unit Sizes 40* - 56*
Outdoor Unit Sizes 80* - 160*
Outdoor Unit Sizes 224* - 280*
Reuse of Existing Pipework - RAV Split Systems
ampair.co.uk | 01707 378 670 | [email protected] 223
Refe
renc
e/Fa
ults
ReferenceConditions & Conversions
ampair.co.uk | 01707 378 670 | [email protected] 223
Refe
renc
e/Fa
ults
Nominal and UK conditions
Nominal capacities (kW) specified in this price book are calculated under ISO-T1 (JIS) standard conditions as follows:
Cooling
Indoor temperature 27ºCDB, 19ºCWBOutdoor temperature 35ºCDB
Heating
Indoor temperature 20ºCDBOutdoor temperature 7ºCDB, 6ºCWB
UK cooling capacities (kW) specified in this price book are calculated under the following conditions:
Indoor temperature 23ºCDB, 16º CWB
Outdoor temperature 30ºCDB
UK heating capacities (kW) specified in this price guide are calculated under the following conditions:
Indoor temperature: 22ºCDBOutdoor temperature: -4ºCWB, -3ºCDB
Electrical
Information relating to local power supplies are shown for guidance only and must be subject to IEE regulations as well as site requirements. All three phase supplies to be TPNE.
Energy labeling
All ENER - Lot 10 information is available atwww.ecodesign.toshiba-airconditioning.eu/en
Pipe size
» 1/4in = 6.35mm» 3/8in = 9.52mm» 1/2in = 12.70mm» 5/8in = 15.88mm» 3/4in = 19.05mm» 7/8in = 22.22mm» 11/8in = 28.58mm» 13/8in = 34.93mm
Conversion data
» kW x 3412 = btu/h» ºC x 1.8 + 32 = ºF» l/s x 3.6 = m3/h» bar x 14.51 = psi» m2 x 10.76 = ft2
Information included in this price book is for guidance only and does not form part of a contract.
@amp_aircon | amp-air-conditioning 224
Refe
renc
e/Fa
ults
ReferenceIndex | RAS & RAV Systems
@amp_aircon | amp-air-conditioning 224
Refe
renc
e/Fa
ults
Section Indoor Unit Outdoor UnitPageNo
RAS Residential 7
Introduction & Range Overview 8
Mirai Wall Mounted - R410A
RAS-07BKV-E RAS-07BAV-E 10
RAS-10BKV-E RAS-10BAV-E 10
RAS-13BKV-E RAS-13BAV-E 11
RAS-16BKV-E RAS-16BAV-E 11
Mirai Wall Mounted - R32
RAS-05BKVG-E RAS-05BAVG-E 12
RAS-07BKVG-E RAS-07BAVG-E 12
RAS-10BKVG-E RAS-10BAVG-E 12
RAS-13BKVG-E RAS-13BAVG-E 13
RAS-16BKVG-E RAS-16BAVG-E 13
AvAnt Wall Mounted
RAS-107SKV-E7 RAS-107SAV-E6 14
RAS-137SKV-E7 RAS-137SAV-E6 14
RAS-167SKV-E7 RAS-167SAV-E5 14
Daiseikai 6 Wall Mounted
RAS-B10N3KVP-E RAS-10N3AVP-E 15
RAS-B13N3KVP-E RAS-13N3AVP-E 15
RAS-B16N3KVP-E RAS-16N3AVP-E 15
Daiseikai 8 Wall Mounted
RAS-10G2KVP-E RAS-10G2AVP-E 16
RAS-13G2KVP-E RAS-13G2AVP-E 16
RAS-16G2KVP-E RAS-16G2AVP-E 16
Bi Flow Floor Standing
RAS-B10UFV-E1 RAS-10N3AV2-E1 17
RAS-B13UFV-E1 RAS-13N3AV2-E1 17
RAS-B18UFV-E1 RAS-18N3AV2-E 17
Multi Split Outdoor Units
RAS-2M14S3AV-E 18
RAS-2M18S3AV-E 18
RAS-3M18S3AV-E 18
RAS-3M26S3AV-E 19
RAS-4M27S3AV-E 19
RAS-5M34S3AV-E 19
Multi Split Indoors RAS-B10N3KVP-E 20
Section Indoor Unit Outdoor UnitPageNo
Multi Split Indoors
RAS-B13N3KVP-E 20
RAS-B16N3KVP-E 20
RAS-B10N3KV2-E1 20
RAS-B13N3KV2-E1 20
RAS-B16N3KV2-E1 20
RAS-B10UFV-E1 21
RAS-B13UFV-E1 21
RAS-B18UFV-E1 21
RAS-M10SMUV-E 21
RAS-M13SMUV-E 21
RAS-M16SMUV-E 21
RAS-M07G3DV-E 22
RAS-M10G3DV-E 22
RAS-M13G3DV-E 22
RAS-M16G3DV-E 22
Combination Tables 23
RAV Split Systems 33
RAV Systems Range Overview 35
Wall Mounted Digital Inverter
RAV-SM307KRTP-E RAV-SM304ATP-E 37
RAV-SM407KRTP-E RAV-SM404ATP-E 37
RAV-SM566KRT-E RAV-SM564ATP-E 38
RAV-SM806KRT-E RAV-SM804ATP-E 38
Wall Mounted Super Digital Inverter
RAV-SM407KRTP-E RAV-SP404ATP-E 39
RAV-SM566KRT-E RAV-SP564ATP-E 39
RAV-SM806KRT-E RAV-SP804ATP-E 39
Compact Cassettes Digital Inverter
RAV-SM304MUT-E RAV-SM304ATP-E 41
RAV-SM404MUT-E RAV-SM404ATP-E 41
RAV-SM564MUT-E RAV-SM564ATP-E 41
Compact Cassettes Super Digital Inverter
RAV-SM404MUT-E RAV-SP404ATP-E 42
ampair.co.uk | 01707 378 670 | [email protected] 225
Refe
renc
e/Fa
ults
ReferenceIndex | RAV Systems
ampair.co.uk | 01707 378 670 | [email protected] 225
Refe
renc
e/Fa
ults
Section Indoor Unit Outdoor UnitPageNo
Compact Cassettes Super Digital Inverter
RAV-SM564MUT-E RAV-SP564ATP-E 42
4 Way Cassettes Digital Inverter
RAV-SM564UTP-E RAV-SM564ATP-E 44
RAV-SM804UTP-E RAV-SM804ATP-E 44
RAV-SM1104UTP-E RAV-SM1104ATP-E 44
RAV-SM1404UTP-E RAV-SM1404ATP-E 45
RAV-SM1604UTP-E RAV-SM1603AT-E 45
4 Way Cassettes Super Digital Inverter Single Phase
RAV-SM564UTP-E RAV-SP564ATP-E 46
RAV-SM804UTP-E RAV-SP804ATP-E 46
RAV-SM1104UTP-E RAV-SP1104AT-E 47
RAV-SM1404UTP-E RAV-SP1404AT-E 47
4 Way Cassettes Super Digital Inverter Three Phase
RAV-SM1104UTP-E RAV-SP1104AT8-E 48
RAV-SM1404UTP-E RAV-SP1404AT8-E 48
RAV-SM1604UTP-E RAV-SP1604AT8-E 48
Slim Ducted Digital Inverter
RAV-SM304SDT-E RAV-SM304ATP-E 50
RAV-SM404SDT-E RAV-SM404ATP-E 50
RAV-SM564SDT-E RAV-SM564ATP-E 50
Slim Ducted Super Digital Inverter
RAV-SM404SDT-E RAV-SP404ATP-E 51
RAV-SM564SDT-E RAV-SP564ATP-E 51
Standard Ducted Digital Inverter
RAV-SM406BTP-E RAV-SM404ATP-E 53
RAV-SM566BTP-E RAV-SM564ATP-E 53
RAV-SM806BTP-E RAV-SM804ATP-E 53
RAV-SM1106BTP-E RAV-SM1104ATP-E 54
RAV-SM1406BTP-E RAV-SM1404ATP-E 54
RAV-SM1606BTP-E RAV-SM1603AT-E 54
Standard Ducted Super Digital Inverter Single Phase
RAV-SM406BTP-E RAV-SP404ATP-E 55
RAV-SM566BTP-E RAV-SP564ATP-E 55
RAV-SM806BTP-E RAV-SP804ATP-E 55
RAV-SM1106BTP-E RAV-SP1104AT-E 56
RAV-SM1406BTP-E RAV-SP1404AT-E 56
Standard Ducted Super Digital Inverter Three Phase RAV-SM1106BTP-E RAV-SP1104AT8-E 57
Section Indoor Unit Outdoor UnitPageNo
Standard Ducted Super Digital Inverter Three Phase
RAV-SM1406BTP-E RAV-SP1404AT8-E 57
RAV-SM1606BTP-E RAV-SP1604AT8-E 57
High Static Ducted Digital Inverter
RAV-SM2242DT-E RAV-SM2244AT8-E 59
RAV-SM2802DT-E RAV-SM2804AT8-E 59
Ceiling Suspended Digital Inverter
RAV-SM407CTP-E RAV-SM404ATP-E 61
RAV-SM567CTP-E RAV-SM564ATP-E 61
RAV-SM807CTP-E RAV-SM804ATP-E 61
RAV-SM1107CTP-E RAV-SM1104ATP-E 62
RAV-SM1407CTP-E RAV-SM1404ATP-E 62
RAV-SM1607CTP-E RAV-SM1603AT-E 62
Ceiling Suspended Super Digital Inverter Single Phase
RAV-SM407CTP-E RAV-SP404ATP-E 63
RAV-SM567CTP-E RAV-SP564ATP-E 63
RAV-SM807CTP-E RAV-SP804ATP-E 63
RAV-SM1107CTP-E RAV-SP1104AT-E 64
RAV-SM1407CTP-E RAV-SP1404AT-E 64
Ceiling Suspended Super Digital Inverter Three Phase
RAV-SM1107CTP-E RAV-SP1104AT8-E 65
RAV-SM1407CTP-E RAV-SP1404AT8-E 65
RAV-SM1607CTP-E RAV-SP1604AT8-E 65
Floor Standing VRF Indoor Unit Conversions
AMP-MML-AP0154BH-E RAV-SM564ATP-E 66
AMP-MML-AP0184BH-E RAV-SM564ATP-E 66
AMP-MML-AP0244BH-E RAV-SM804ATP-E 66
AMP-MML-AP0154H-E RAV-SM564ATP-E 66
AMP-MML-AP0184H-E RAV-SM564ATP-E 66
AMP-MML-AP0244H-E RAV-SM804ATP-E 66
AMP-MMF-AP0156H-E RAV-SM564ATP-E 67
AMP-MMF-AP0246H-E RAV-SM804ATP-E 67
AMP-MMF-AP0276H-E RAV-SM804ATP-E 67
AMP-MMF-AP0366H-E RAV-SM1104ATP-E 67
AMP-MMF-AP0486H-E RAV-SM1404ATP-E 67
AMP-MMF-AP0566H-E RAV-SM1603AT-E 67
@amp_aircon | amp-air-conditioning 226
Refe
renc
e/Fa
ults
ReferenceIndex | RAV & VRF Systems
@amp_aircon | amp-air-conditioning 226
Refe
renc
e/Fa
ults
Section Indoor Unit Outdoor UnitPageNo
Floor Standing VRF Indoor Unit Conversions
AMP-MMF-AP0156H-E RAV-SP564ATP-E 68
AMP-MMF-AP0246H-E RAV-SP804ATP-E 68
AMP-MMF-AP0276H-E RAV-SP804ATP-E 68
AMP-MMF-AP0366H-E RAV-SP1104AT-E 68
AMP-MMF-AP0486H-E RAV-SP1404AT-E 68
AMP-MMF-AP0566H-E RAV-SP1604AT8-E 68
Digital Inverter Twin Split Systems 70
Super Digital Inverter Twin Split Systems 72
Digital Inverter Triple Split Systems 74
Super Digital Inverter Triple Split Systems 76
Digital Inverter & Super Digital Inverter Quad Split Systems 78
VRF Systems 81
VRF Outdoor Range Overview 83
Mini SMMS Heat Pump Outdoor Units
MCY-MAP0401HT 84
MCY-MAP0501HT 84
MCY-MAP0601HT 84
SMMSe Heat Pump Outdoor Units
MMY-MAP0806HT8P-E 85
MMY-MAP1006HT8P-E 85
MMY-MAP1206HT8P-E 85
MMY-MAP1406HT8P-E 86
MMY-MAP1606HT8P-E 86
MMY-MAP1806HT8P-E 86
MMY-MAP2006HT8P-E 87
MMY-AP2206HT8P-E 87
MMY-AP2416HT8P-E 88
MMY-AP2616HT8P-E 88
MMY-AP2816HT8P-E 88
MMY-AP3016HT8P-E 89
MMY-AP3216HT8P-E 89
Section Indoor Unit Outdoor UnitPageNo
SMMSe Heat Pump Outdoor Units
MMY-AP3416HT8P-E 89
MMY-AP3616HT8P-E 90
MMY-AP3816HT8P-E 90
MMY-AP4016HT8P-E 90
MMY-AP4216HT8P-E 91
MMY-AP4416HT8P-E 91
MMY-AP4616HT8P-E 92
MMY-AP4816HT8P-E 92
MMY-AP5016HT8P-E 92
MMY-AP5216HT8P-E 93
MMY-AP5416HT8P-E 93
MMY-AP5616HT8P-E 93
MMY-AP5816HT8P-E 94
MMY-AP6016HT8P-E 94
SHRMi Heat Recovery Outdoor Units
MMY-MAP0804FT8-E 95
MMY-MAP1004FT8-E 95
MMY-MAP1204FT8-E 95
MMY-MAP1404FT8-E 96
MMY-AP1614FT8-E 96
MMY-AP1814FT8-E 96
MMY-AP2014FT8-E 97
MMY-AP2214FT8-E 97
MMY-AP2414FT8-E 97
MMY-AP2614FT8-E 98
MMY-AP2814FT8-E 98
MMY-AP3014FT8-E 98
MMY-AP3214FT8-E 99
MMY-AP3414FT8-E 99
MMY-AP3614FT8-E 100
MMY-AP3814FT8-E 100
ampair.co.uk | 01707 378 670 | [email protected] 227
Refe
renc
e/Fa
ults
ReferenceIndex | VRF Systems
ampair.co.uk | 01707 378 670 | [email protected] 227
Refe
renc
e/Fa
ults
Section Indoor Unit Outdoor UnitPageNo
SHRMi Heat Recovery Outdoor Units
MMY-AP4014FT8-E 101
MMY-AP4214FT8-E 101
VRF Indoor 102
Flow Selector Units & Branch Pipes 102
VRF Indoor - Range Overview 103
UK Cooling Capacities 104
UK Heating Capacities 105
1 Way Cassette
MMU-AP0074YH1-E 106
MMU-AP0094YH1-E 106
MMU-AP0124YH1-E 106
MMU-AP0154SH1-E 107
MMU-AP0184SH1-E 107
MMU-AP0244SH1-E 107
4 Way Compact Cassette
MMU-AP0056MH1-E 108
MMU-AP0074MH1-E 108
MMU-AP0094MH1-E 108
MMU-AP0124MH1-E 109
MMU-AP0154MH1-E 109
MMU-AP0184MH1-E 109
4 Way Cassette
MMU-AP0094HP1-E 110
MMU-AP0124HP1-E 110
MMU-AP0154HP1-E 110
MMU-AP0184HP1-E 111
MMU-AP0244HP1-E 111
MMU-AP0274HP1-E 112
MMU-AP0304HP1-E 112
MMU-AP0364HP1-E 112
MMU-AP0484HP1-E 113
MMU-AP0564HP1-E 113
Section Indoor Unit Outdoor UnitPageNo
2 Way Cassette
MMU-AP0072WH1-E 114
MMU-AP0092WH1-E 114
MMU-AP0122WH1-E 114
MMU-AP0152WH1-E 115
MMU-AP0182WH1-E 115
MMU-AP0242WH1-E 115
MMU-AP0272WH1-E 116
MMU-AP0302WH1-E 116
MMU-AP0362WH1-E 116
MMU-AP0482WH1-E 117
MMU-AP0562WH1-E 117
Standard Ducted
MMD-AP0076BHP1-E 118
MMD-AP0096BHP1-E 118
MMD-AP0126BHP1-E 118
MMD-AP0156BHP1-E 119
MMD-AP0186BHP1-E 119
MMD-AP0246BHP1-E 120
MMD-AP0276BHP1-E 120
MMD-AP0306BHP1-E 120
MMD-AP0366BHP1-E 121
MMD-AP0486BHP1-E 121
MMD-AP0566BHP1-E 121
Slim Ducted
MMD-AP0056SPH1-E 122
MMD-AP0074SPH1-E 122
MMD-AP0094SPH1-E 123
MMD-AP0124SPH1-E 123
MMD-AP0154SPH1-E 124
MMD-AP0184SPH1-E 124
MMD-AP0244SPH1-E 125
MMD-AP0274SPH1-E 125
@amp_aircon | amp-air-conditioning 228
Refe
renc
e/Fa
ults
ReferenceIndex | VRF Systems, Air Handling & HRV
@amp_aircon | amp-air-conditioning 228
Refe
renc
e/Fa
ults
Section Indoor Unit Outdoor UnitPageNo
High Static Ducted
MMD-AP0186HP1-E 126
MMD-AP0246HP1-E 126
MMD-AP0276HP1-E 126
MMD-AP0366HP1-E 127
MMD-AP0486HP1-E 127
MMD-AP0566HP1-E 127
MMD-AP0726HP1-E 128
MMD-AP0966HP1-E 128
High Static Ducted - High Flow
MMD-AP0364H-EU 129
MMD-AP0484H-EU 129
MMD-AP0564H-EU 129
Wall Mounted 3 Series
MMK-AP0073H1 130
MMK-AP0093H1 130
MMK-AP0123H1 130
MMK-AP0153H1 131
MMK-AP0183H1 131
MMK-AP0243H1 131
Wall Mounted 4 Series
MMK-AP0054MHP-E1 132
MMK-AP0074MHP-E1 132
MMK-AP0094MHP-E1 133
MMK-AP0124MHP-E1 133
Ceiling Suspended
MMC-AP0157HP1-E 134
MMC-AP0187HP1-E 134
MMC-AP0247HP1-E 135
MMC-AP0277HP1-E 135
MMC-AP0367HP1-E 136
MMC-AP0487HP1-E 136
MMC-AP0567HP1-E 136
Floor Mounted Cabinet
MMF-AP0156H1-E 137
MMF-AP0186H1-E 137
Section Indoor Unit Outdoor UnitPageNo
Floor Mounted Cabinet
MMF-AP0246H1-E 138
MMF-AP0276H1-E 138
MMF-AP0366H1-E 139
MMF-AP0486H1-E 139
MMF-AP0566H1-E 139
Floor Standing Chassis
MML-AP0074BH1-E 140
MML-AP0094BH1-E 140
MML-AP0124BH1-E 140
MML-AP0154BH1-E 141
MML-AP0184BH1-E 141
MML-AP0244BH1-E 141
Floor Standing Console
MML-AP0074H1-E 142
MML-AP0094H1-E 142
MML-AP0124H1-E 142
MML-AP0154H1-E 143
MML-AP0184H1-E 143
MML-AP0244H1-E 143
Floor Standing Bi Flow Console
MML-AP0074NH1-E 144
MML-AP0094NH1-E 144
MML-AP0124NH1-E 144
MML-AP0154NH1-E 145
MML-AP0184NH1-E 145
Air Handling & HRV 147
Air to Air Heat Exchangers with DX Coil
MMD-VN502HEX1E 148
MMD-VN802HEX1E 148
MMD-VN1002HEX1E 148
Air to Air Heat Exchangers with DX Coil & Humidifier
MMD-VNK502HEX1E 149
MMD-VNK802HEX1E 149
MMD-VNK1002HEX1E 149
ampair.co.uk | 01707 378 670 | [email protected] 229
Refe
renc
e/Fa
ults
ReferenceIndex | Air Handling, HRV & Applied
ampair.co.uk | 01707 378 670 | [email protected] 229
Refe
renc
e/Fa
ults
Section Indoor Unit Outdoor UnitPageNo
Fresh Air Intake Units
MMD-AP0481HFE 150
MMD-AP0721HFE 150
MMD-AP0961HFE 150
Heat Recovery Ventilation Units
VN-M150HE 151
VN-M250HE 151
VN-M350HE 151
VN-M500HE 152
VN-M650HE 152
VN-M800HE 152
VN-M1000HE 153
VN-M1500HE 153
VN-M2000HE 153
VRF Air Handling Unit Interface
MM-DXC010 MM-DXV080 154
MM-DXC010 MM-DXV080 154
MM-DXC010 MM-DXV080 154
MM-DXC010 MM-DXV140 154
MM-DXC010 MM-DXV140 155
MM-DXC010 MM-DXV140 155
MM-DXC010 MM-DXV280 155
MM-DXC010 MM-DXV280 155
Air Handling Unit Interface for Digital Inverters
RAV-SM304ATP-E 156
RAV-SM404ATP-E 156
RAV-SM564ATP-E 156
RAV-SM804ATP-E 157
RAV-SM1104ATP-E 157
RAV-SM1404ATP-E 157
RAV-SM1603AT-E 158
RAV-SM2244AT8-E 158
RAV-SM2804T8-E 158
RAV-SM2804T8-E 158
Section Indoor Unit Outdoor UnitPageNo
Air Handling Unit Interface for Super Digital Inverters
RAV-SP404AT-E 59
RAV-SP564ATP-E 159
RAV-SP804ATP-E 159
RAV-SP1104AT-E 160
RAV-SP1104AT8-E 160
RAV-SP1404AT-E 161
RAV-SP1404AT8-E 161
RAV-SP1604AT8-E 161
Applied Products & Air to Water 163
Air Curtain - Free Hanging - Digital Inverter
RAV-CT101CH-M RAV-SM804ATP-E 166
RAV-CT101CH-L RAV-SM804ATP-E 166
RAV-CT151CH-M RAV-SM1104ATP-E 166
RAV-CT151CH-L RAV-SM1104ATP-E 166
RAV-CT201CH-M RAV-SM1404ATP-E 167
RAV-CT201CH-L RAV-SM1404ATP-E 167
RAV-CT251CH-M RAV-SM1603AT-E 167
RAV-CT251CH-L RAV-SM1603AT-E 167
Air Curtain - Free Hanging - Super Digital Inverter
RAV-CT101CH-M RAV-SP804ATP-E 168
RAV-CT101CH-L RAV-SP804ATP-E 168
RAV-CT151CH-M RAV-SP1104AT-E 168
RAV-CT151CH-M RAV-SP1104AT8-E 168
RAV-CT151CH-L RAV-SP1104AT-E 169
RAV-CT151CH-L RAV-SP1104AT8-E 169
RAV-CT201CH-M RAV-SP1404AT-E 169
RAV-CT201CH-M RAV-SP1404AT8-E 169
RAV-CT201CH-L RAV-SP1404AT-E 170
RAV-CT201CH-L RAV-SP1404AT8-E 170
RAV-CT251CH-M RAV-SP1604AT8-E 170
RAV-CT251CH-L RAV-SP1604AT8-E 170
@amp_aircon | amp-air-conditioning 230
Refe
renc
e/Fa
ults
ReferenceIndex | Applied Products
@amp_aircon | amp-air-conditioning 230
Refe
renc
e/Fa
ults
Section Indoor Unit Outdoor UnitPageNo
Air Curtain - Cassette Type - Digital Inverter
RAV-CT101UH-M RAV-SM804ATP-E 171
RAV-CT101UH-L RAV-SM804ATP-E 171
RAV-CT151UH-M RAV-SM1104ATP-E 171
RAV-CT151UH-L RAV-SM1104ATP-E 171
RAV-CT201UH-M RAV-SM1404ATP-E 172
RAV-CT201UH-L RAV-SM1404ATP-E 172
RAV-CT251UH-M RAV-SM1603AT-E 172
RAV-CT251UH-L RAV-SM1603AT-E 172
Air Curtain - Cassette Type - Super Digital Inverter
RAV-CT101UH-M RAV-SP804ATP-E 173
RAV-CT101UH-L RAV-SP804ATP-E 173
RAV-CT151UH-M RAV-SP1104AT-E 173
RAV-CT151UH-M RAV-SP1104AT8-E 173
RAV-CT151UH-L RAV-SP1104AT-E 174
RAV-CT151UH-L RAV-SP1104AT8-E 174
RAV-CT201UH-M RAV-SP1404AT-E 174
RAV-CT201UH-M RAV-SP1404AT8-E 174
RAV-CT201UH-L RAV-SP1404AT-E 175
RAV-CT201UH-L RAV-SP1404AT8-E 175
RAV-CT251UH-M RAV-SP1604AT8-E 175
RAV-CT251UH-L RAV-SP1604AT8-E 175
Air Curtain - Built-In - Digital Inverter
RAV-CT101BH-M RAV-SM804ATP-E 176
RAV-CT101BH-L RAV-SM804ATP-E 176
RAV-CT151BH-M RAV-SM1104ATP-E 176
RAV-CT151BH-L RAV-SM1104ATP-E 176
RAV-CT201BH-M RAV-SM1404ATP-E 177
RAV-CT201BH-L RAV-SM1404ATP-E 177
RAV-CT251BH-M RAV-SM1603AT-E 177
RAV-CT251BH-L RAV-SM1603AT-E 177
Air Curtain - Built-In - Super Digital Inverter
RAV-CT101BH-M RAV-SP804ATP-E 178
RAV-CT101BH-L RAV-SP804ATP-E 178
Section Indoor Unit Outdoor UnitPageNo
Air Curtain - Built-In - Super Digital Inverter
RAV-CT151BH-M RAV-SP1104AT-E 178
RAV-CT151BH-M RAV-SP1104AT8-E 178
RAV-CT151BH-L RAV-SP1104AT-E 179
RAV-CT151BH-L RAV-SP1104AT8-E 179
RAV-CT201BH-M RAV-SP1404AT-E 179
RAV-CT201BH-M RAV-SP1404AT8-E 179
RAV-CT201BH-L RAV-SP1404AT-E 180
RAV-CT201BH-L RAV-SP1404AT8-E 180
RAV-CT251BH-M RAV-SP1604AT8-E 180
RAV-CT251BH-L RAV-SP1604AT8-E 180
Air Curtain - Free Hanging - VRF
RAV-CT101CH-M 181
RAV-CT101CH-L 181
RAV-CT151CH-M 181
RAV-CT151CH-L 181
RAV-CT201CH-M 181
RAV-CT201CH-L 181
RAV-CT251CH-M 181
RAV-CT251CH-L 181
Air Curtain - Cassette Type - VRF
RAV-CT101UH-M 182
RAV-CT101UH-L 182
RAV-CT151UH-M 182
RAV-CT151UH-L 182
RAV-CT201UH-M 182
RAV-CT201UH-L 182
RAV-CT251UH-M 182
RAV-CT251UH-L 182
Air Curtain - Built-In - VRF
RAV-CT101BH-M 183
RAV-CT101BH-L 183
RAV-CT151BH-M 183
RAV-CT151BH-L 183
ampair.co.uk | 01707 378 670 | [email protected] 231
Refe
renc
e/Fa
ults
ReferenceIndex | Applied Products, Air to Water & Misc
ampair.co.uk | 01707 378 670 | [email protected] 231
Refe
renc
e/Fa
ults
Section Indoor Unit Outdoor UnitPageNo
Air Curtain - Built-In - VRF
RAV-CT151BH-L 183
RAV-CT201BH-M 183
RAV-CT201BH-L 183
RAV-CT251BH-M 183
RAV-CT251BH-L 183
Estia - Outdoor Units - Standard - Single Phase
HWS-804H-E1 184
HWS-1104H-E1 184
HWS-1404H-E1 184
Estia - Outdoor Units - Standard - Three Phase
HWS-1104H8-E1 185
HWS-1404H8-E1 185
HWS-1604H8-E1 185
Estia - Hot Water Tanks - Standard
HWS-1501CSHM3-UK 187
HWS-2101CSHM3-UK 187
HWS-3001CSHM3-UK 187
Estia - Hydro Units - Standard
HWS-804XWHM3-E1 188
HWS-804XWHT6-E1 188
HWS-1404XWHM3-E1 189
HWS-1404XWHT6-E1 189
HWS-1404XWHT9-E1 189
Estia - Outdoor Units - High Temperature - Single Phase
HWS-P804HR-E1 190
HWS-P1104HR-E1 190
Estia - Hot Water Tanks - High Temperature
HWS-1501CSHM3-UK 191
HWS-2101CSHM3-UK 191
HWS-3001CSHM3-UK 191
Estia - Hydro Units - High Temperature
HWS-P804XWHM3-E1 192
HWS-P804XWHT6-E1 192
HWS-P804XWHT6-E1 192
HWS-1104XWHM3-E1 193
HWS-1104XWHT6-E1 193
HWS-1104XWHT9-E1 193
SectionPageNo
Controls & Accessories 195
Wired & Wireless Remote Controllers 196
Centralised Remote Controllers 197
Centralised Remote Controllers - PC Based 198
BMS Interfaces 199
Indoor Unit Wiring Adapters 202
Outdoor Unit Wiring Adapters 203
Leak Detection 204
Brackets, Trays, Cages & Other Accessories 206
Toshiba Rewards 207
Introduction 208
Warranty 209
Rewards Gift Cards 210
Toshiba Unit & Installation Tools 211
Marketing Contribution & Project Support 212
Application 213
Reference/Faults 215
RAV Fault Codes 216
VRF Fault Codes 218
Replacement Technology Tables 222
Conditions & Conversions 223
Index 224
Terms and Conditions 232
@amp_aircon | amp-air-conditioning 232
Refe
renc
e/Fa
ults
ReferenceTerms and Conditions
@amp_aircon | amp-air-conditioning 232
Refe
renc
e/Fa
ults
The use of this product guide is subject to the following terms of use:
The term ‘AMP Air Conditioning’, ‘AMP’, ‘AMP Air’, ’AMP Diamonds’, ‘the Diamond scheme’ or ‘us’ or ‘we’ refers to AMP Air Conditioning Limited. Our registered office is Blenheim House, Blenheim Court, Brownfields, Welwyn Garden City, Herts, AL7 1AD. Our company registration number is 2371708. The term ‘you’ or ‘your’ refers to the user or viewer of our product guide.
» The content of this product guide is for your general information and use only. It is subject to change without notice and does not form part of any contract.
» Prices within this guide are subject to change without notice.
» Neither we nor any third parties provide any warranty or guarantee as to the accuracy, completeness or suitability of the information and materials found or offered in this product guide for any particular purpose. You acknowledge that such information and materials may contain inaccuracies or errors and we expressly exclude liability for any such inaccuracies or errors to the fullest extent permitted by law.
» This product guide contains material which is owned by or licensed to us. This material includes, but is not limited to, the design, layout, look, appearance, photographs and graphics. Reproduction is prohibited other than in accordance with the copyright notice, which forms part of these terms and conditions.
» Product images within this product guide are for illustrative purposes only and do not necessarily represent the exact products, services or ideas in the context in which they are found. Actual products may differ from those shown.
» All trademarks reproduced in this guide, which are not the property of, or licensed to AMP, are acknowledged in the guide.
» Unauthorised use of this product guide may give to a claim for damages and/or be a criminal offence.
» This product guide provides links to third party websites. These links are provided for your convenience to provide further information. They do not signify that we endorse the website(s). We have no responsibility for the content of the linked website(s).
» Your use of this product guide and any dispute arising out of such use of the website is subject to the laws of England and Wales.
» In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this product guide.
For more information about AMP or these terms and conditions, please contact us:
Tel: 01707 378 670Email: [email protected]: AMP Air Conditioning Blenheim House Blenheim Court Brownfields Welwyn Garden City Herts AL7 1AD
ISO 14001:2004Certificate No. EN1749
REGISTERED COMPANY
R
REGISTERED COMPANYISO 9001:2008
Certificate No. CA14723
R
AMP Air Conditioning is an ISO 14001:2004 and 9001:2008 accredited company.
© AMP Air Conditioning Ltd, 2016
ampair.co.uk | 01707 378 670 | [email protected] Air Conditioning, Blenheim House, Blenheim Court, Brownfields, Welwyn Garden City, Herts AL7 1AD