Tomahawk Tw

Embed Size (px)

Citation preview

  • 8/12/2019 Tomahawk Tw

    1/30

    TOMAHAWK TW-9010CONTENTS

    USER MANUAL123456789101112131415161718192021222324252627282930313233343

    5123456System main featuresRemote control trinketsLCD featuresArming

    modeArming with siren disabledAutomatic arming and re-armingImmobilizer featuresDisarmingOpening/closing doors with engine

    workingTwo-step door opening/channel 3Remote engine start-upRemote

    engine cut-off Turbo timer Warming-up engine to specified

    temperatureDaily (1, 2, 4, 12-hour) automatic start-upRemote status

    scanningRemote boot opening2nd auxiliary channelCar searchingRemote

    shock sensor disablingAlarm modesPanic modeAnti-hijack

    modeValet modeCall driverOverride button functionsEmergency

    arming/disarmingRemote start-up preparation for cars with manual

    transmissionProgramming auxiliary trinketsLED indicator operation

    modesTrinket-pager battery replacementProgramming modeProgramming

    trinket-pager functionsProgramming tableDescription of programmable

    functions

    INSTRUCTIONS FOR INSTALLATIONBasic installation principlesChoosing locations for main unitsWire

    connectionsSelection of manual or automatic transmissionConnection of

    central lock Setting shock sensor Connection diagramEngineering

    data234667777888991010111111111112121213131415151616171819202323252728282937

    1

    TOMAHAWK TW-9010USER MANUAL

    1 . S y s t e m M a i n F e a t u r e s

    5-button 2-side programmable trinket with LCD

    LCD backlight

    Vibration mode

    Anti-scanner

    Anti-grabber

    Programmable trinkets (up to 4 items)

    Visual and sound confirmation of functions performed

  • 8/12/2019 Tomahawk Tw

    2/30

    Arming with siren disabled

    Secured remote engine start-up/cut-off

    Installation option for cars with automatic or manual transmission

    Installation option for cars with gasoline or diesel engines

    Cabin temperature control

    Auxiliary temperature sensor

    Automatic engine warm-up to specified temperature

    Daily (1, 2, 4, 12-hour) automatic start-up

    Defective area bypass with visual and sound confirmation

    Two-zone shock sensor

    Remote shock sensor disabling

    Protection against mis-operations

    Self-diagnostics

    3 extra channels

    Anti-hijack modePanic modeValet mode

    Doors, hood and boot security

    Trinket-pager battery charge indicationTrinket-pager battery power-saving

    mode

    Driver calling featureCar searchingClock, alarm-clock and timer built in

    trinket-pager System status LED indicationCentral lock built-in

    relayStatus memoryTwo-step disarmingTwo-step central lockopeningEngine lockingAutomatic pager active area controlTurbo timer

  • 8/12/2019 Tomahawk Tw

    3/30

    2

  • 8/12/2019 Tomahawk Tw

    4/30

  • 8/12/2019 Tomahawk Tw

    5/30

    TOMAHAWK TW-90102.Remote Control Trinkets 3

    TOMAHAWK TW-9010

  • 8/12/2019 Tomahawk Tw

    6/30

    3 . L C D F e a t u r e s Fig. 31 . - - s e c u r i t y

    m o d e

    i n d i c a t i o n . 2 .

    s i l e n t s e c u r i t y m o d e i n d i c a t i o n 3 .

    c l o s e d c e n t r a l l o c k

    i n d i c a t i o n 4 . - - o p e n

    c e n t r a l l o c k

    i n d i c a t i o n 5 .

    o p e n d o o r ( s )

    i n d i c a t i o n 6 .

    o p e n h o o d

    i n d i c a t i o n 7 .

    o p e n b o o t

    i n d i c a t i o n 8 . -

    p a r k i n g l i g h t s

    f l a s h i n g i n d i c a t i o n

    4

    TOMAHAWK TW-90109.

    trinket-pager transceiver operation indication1 0 .

    i n d i c a t i o n f o r p r e s e n c e i n

    a c t i v e z o n e 1 1 . p o w e r -

    s a v i n g m o d e

    i n d i c a t i o n 1 2 . d r i v e r

    c a l l i n d i c a t i o n 1 3 .

    w a r m - u p t o s p e c i f i e d

    t e m p e r a t u r e m o d e

    i n d i c a t i o n 1 4 . d a i l y a u t os t a r t i n d i c a t i o n 1 5 . -

    l i g h t s h o c k

    i n d i c a t i o n 1 6 . s t r o n g

    s h o c k i n d i c a t i o n 1 7 . 1 -

    s h o c k s e n s o r w a r n i n g z o n e

    d i s a b l i n g i n d i c a t i o n 1 7 . 2 -

    s h o c k s e n s o r d i s a b l e

    i n d i c a t i o n 18. - Anti-Hijack modeindication1 9 . - v i b r a t i o n

  • 8/12/2019 Tomahawk Tw

    7/30

    m o d e

    i n d i c a t i o n 2 0 . -

    V a l e t m o d e

    i n d i c a t i o n

    5TOMAHAWK TW-90102 1 . - h a n d - b r a k e

    d i s e n g a g e

    i n d i c a t i o n 2 2 . -

    s t a r t e d e n g i n e

    i n d i c a t i o n 2 3 . -

    b a t t e r y l e v e l

    i n d i c a t i o n 2 4 . - t i m e r

    s w i t c h - o n

    i n d i c a t i o n 2 5 . - a l a r m -

    c l o c k s w i t c h - o n

    i n d i c a t i o n 2 6 .

    -

    c l o c k 2

    7 . - t e m p e r a t u r e m e a s u r e m e n t

    u n i t s ( C o r F )

    4 . A r m i n g M o d e To arm a car, I is necessary to press button 1 time. Parking lights will flash

    1 time; siren willsound 1 CHIRP to confirm entry in security mode,

    doors and windows will close (if connected).LCD will display icons and

    .In case when siren sounds 3 CHIRPS, i t means that the

    system detected and disabled adefective zone (open door,

    hood, boot or hand-brake disengaged). The system will

    automaticallytake this zone for protection as soon as the zone is repaired

    (door, hood, boot closed and hand-brakeengaged).

    5.Arming Mode with Siren Disabled To arm a car without siren sounds (all messages and confirmations will be

    sent by the system tothe trinket-pager only), press button 1 time. Parking

    lights will flash 1 time to confirm entry insecurity mode, doors will close.

    LCD will display icons and .You can also switch this mode ON and OFF

    while in security mode.

    6

    TOMAHAWK TW-9010

    6.Auto Arming and Re-arming

  • 8/12/2019 Tomahawk Tw

    8/30

    If the auto arming function is enabled, then: with ignition OFF,

    after all doors are closed thesys tem wi ll ale rt wi th 1 long

    CHIRP and wil l switch securi ty mode ON 10 sec la ter

    (seeProgramming Table).Auto re-arming function is always enabled

    in the case when after disarming none of the doorsopen within 30sec.

    7 . I m m o b i l i z e r M o d e The immobilizer mode is enabled automatically 30 sec after ignition cut-

    off (see ProgrammingTable). LED indicator glows continuously in this

    mode. In this mode, engine start-up with ignitionkey is not possible.To

    exit the immobilizer mode, press button 1 time or switch ignition OFF and

    press buttonOVERRIDE 1 time.

    8 . D i s a r m i n g To disarm vehicle, press button 1 time. Parking lights will flash 2 times;

    siren will sound 2CHIRPS (if the system is not in security mode

    with siren disabled) to confirm disarming, doorswill open and

    lighting will go in (if connected). LCD will display icon .

    9.Door Opening/Closing with Engine WorkingIf the car engine was started with ignition key, then you can open and

    close doors with button. LCD will display icons and respectively.

    7

    TOMAHAWK TW-901010.Two-step Door Opening or Channel 3

    These fun cti ons ar e not avai l able at the same time! Use

    Pr ogr amming Tabl e to sel ect onethereof.1.Two- step door opening function is selected.Press button to

    disarm and open the drivers door. Second press and hold of this button

    willopen other doors.2.Auxiliary channel function is

    selected.Press and hold button to enable an auxiliary (supplementary)

    channel.

    ATTENTION!These functions require additional connection while installation.

    11.Turbo TimerTomahawk TW-9010 provides a turbo function for vehicles with turbo

    engines. If this functionis enabled, the engine keeps on running after

    ignition OFF for 1, 3 or 6 min (see ProgrammingTable).

    12.Remote Engine Start-upPress button . Parking lights will flash 3 times; siren will sound 3

    CHIRPS. LCD willdisplay the following icons:1 . e n g i n es t a r t - u p a t t e m p t . 2 . i f e n g i n e f a i l s t o

  • 8/12/2019 Tomahawk Tw

    9/30

    s t a r t f o r a n y r e a s o n . 3 . e n g i n e

    s t a r t e d ( a c c o m p a n i e d b y

    t r i n k e t - p a g e r m e l o d y ) The engine will

    run during pre-programmed time (see Programming Table), after

    which willstop automatically. The run time can be prolonged usingbut tons and by 5 min after each press, to 20 min maximum. LCD

    will display time before engine stop.

    8

    TOMAHAWK TW-9010

    ATTENTION!Remote engine start-up cannot be done in the case if:1 . G e a r l e v e r

    i s

    notin neutral position.2 . Ig n i t i on sw i t ch ed ON .3 . T h e h o o d i s

    o p e n . 4 . T h e h a n d - b r a k e i s

    notengaged.In any of these occasions, siren will sound 4 CHIRPS at a

    remote start-up attempt.

    13.Remote Engine StopIn the case when the engine was started using remote start-up, you can

    stop it by pressing button. Parking lights will flash 4 times; siren willsound 4 CHIRPS. LCD will hide icon anda melody will play.

    14.Warming-up Engine to Specified TemperatureTomahawk provides for an auxiliary temperature sensor for

    installation under the hood (seeDiagram No.10). If this sensor is

    installed, engine start and warm-up is performed by this sensorsdata,

    otherwise by the cabin temperature sensor data.To enable this function,

    press and hold buttons and simultaneously. Parking lightswill flash 1 time

    and siren will sound 1 CHIRP to confirm enabling the function. LCD

    will displayicon and the specified temperature for warm-up switch-on (programmable, see ProgrammingTable) accompanied with a

    melody. When temperature reaches the specified value for

    automaticwarm-up switch-on, the engine will start for previously

    programmed time (see Programming Table).

    9To disable this function, press buttons and . Parking lights will

    flash 2 times and

    TOMAHAWK TW-9010

  • 8/12/2019 Tomahawk Tw

    10/30

    siren will sound 2 CHIRPS to confirm disabling the function.

    LCD will hide icon and amelody will play.

    Note:Automatic engine warming-up to specified temperature should be made

    six times per two hoursas maximum.Temperature for automatic enginewarming-up may be set at -5C, -10C, -20C, -30C

    (seeProgramming Table).15.

    Daily

    (1, 2, 4, 12-hour) Automatic Start-upTo enable this function, press and hold buttons and

    simultaneously. Siren willsound 1 CHIRP to confirm enabling the

    function. LCD will display icon and a melody will play.After this function

    is enabled, beginning from the next day, the system will automatically

    startengine at the time of enabling.To disable the daily start-up function,

    press buttons and . Parking lights will flash 2times and siren will sound 2

    CHIRPS to confirm disabling the function. LCD will hide iconand a

    melody will play.To enable 1, 2, 4 and 12 hour start-up, it is necessary to

    enable the daily start function and thenduring 5 seconds to press the

    respective button on the trinket:for hourly start,for start-up every 2

    hours,for start-up every 4 hours,for start-up every 12 hours.

    16.Remote Status Scanning

    To perform remote status scanning, press button . Parking lights will flash3 times to confirmdata transfer to the trinket-pager receiver; temperature in

    the cabin, security status, etc.

    10

    TOMAHAWK TW-9010

    17.Remote Boot OpeningTo remotely open the boot , press and hold but ton . Parking

    l ig hts wil l fl as h 3 t ime s to confirm the boot opening. LCD will

    display icon

    .ATTENTION!This function requires auxiliary connection while installation

    .

    18.2-nd Auxiliary ChannelTo enable this function, press and hold button . Parking lights will flash 1

    time, siren willsound 1 CHIRP to confirm enabling the function.

    ATTENTION!

    This function requires auxiliary connection while installation.19.Car Search

  • 8/12/2019 Tomahawk Tw

    11/30

    To enable this function, press and hold buttons and simultaneously.

    Parking lights willflash 6 times and siren will sound 6 CHIRPS to show

    car location.

    20.Remote Shock Sensor Cut-off

    To enable this function, while in security mode press and hold buttonsandsimultaneously. LCD will display icon to show that the shock sensor

    warning zone isdisabled. Second press on the buttons will disable the

    shock sensor completely and LCD will displayicon

    .To enable the shock sensor, press buttons and once again.

    21.Alarm ModesOn triggering the shock sensor warning zone (light shock),

    parking lights will flash 6 times,siren will sound 3 CHIRPS. LCD

    will display icon and a melody will play.

    11

    TOMAHAWK TW-9010On triggering the shock sensor main zone (strong shock), the system will

    enable alarm mode for 25 sec. LCD will display icon and an alarm signal

    will sound.On triggering any other zone, the system will enable alarm

    mode for 30 sec. LCD will display anicon corresponding to

    the triggered zone

    (see page 3)

    and an alarm signal will sound.

    ATTENTION!To disable the alarm signal, press button . This will cut the alarm mode off

    but the car will remainsecured.

    22.Panic Mode

    To enable this function, press and hold buttons and simultaneously, enginemust not bestarted. Parking lights will flash 3 times and siren will sound 3

    CHIRPS to attract attention to yourcar.

    23.Anti-Hijack ModeTo enable this function, press and hold buttons and simultaneously.

    Parking lights willflash for 30 sec, then the system will enable alarm

    mode, engine starter will be locked. LCD willdisplay icon and an alarm

    signal will sound.To disable this mode, press button .This mode can be

    also enabled using button Anti-hijack. Press button Anti-hijack(car engine must be started). Parking lights will blink for 30 sec, after

  • 8/12/2019 Tomahawk Tw

    12/30

    which the system will enablealarm mode, engine starter will be locked.

    This mode will not be disabled before button is pressed. You can also exit

    this mode by holding button Anti-hijack for 5 sec.

    24.Valet Mode

    To enable this function, press and hold buttons,and simultaneously. Parkinglights will flash 4 times and siren will

    sound 4 CHIRPS to confirm Valet mode enabling. LC Dwill

    display icon

    ,and a melody will play.

    12

    TOMAHAWK TW-9010In this mode, only service functions are available, such as

    auxiliary channels, car search, calldriver, etc. Also available are re-

    arming function and programming mode.To disable this funct ion,

    again press

    ,and simultaneously. Parking lights willflash 3 times and siren will

    sound 3 CHIRPS to confirm Valet mode disabling. LCD will hide icon

    ,

    and a melody will play.25.Call DriverTo enable this function, press call button located on antenna-transmitter.

    LCD will display icon

    ,and a melody will play.

    26.Override Button FunctionsSome of TOMAHAWK TW-9010 functions can be enabled

    without control trinkets. To enter this mode, do the

    fo l l owi ng : 1 . Swi t c h i gn i t i on OFF 2.Using Override buttonto select required function:A)Valet mode 3 t imesB)Daily

    auto star t 4 timesC)Auto warm-up to specified cabin

    temperature 5 times3 . S w i t c h i g n i t i o n O N 4.The system

    will confirm the selected function with siren CHIRPS and LED

    flashes:A)Valet mode 3 CHIRPS and flashesB)Daily auto start

    4 CHIRPS and flashesC)Auto warm-up to specified cabin

    temperature 5 CHIRPS and flashes5.To enable/disable the

    functions, press button Override6.The system wil l confirm

  • 8/12/2019 Tomahawk Tw

    13/30

    enabl ing/disabl ing the funct ion with si ren CHIRPS and

    LEDflashes:

    13

    TOMAHAWK TW-9010

    1 CHIRP and flash function enabled2 CHIRPS and flashes function disabled7 . S w i t c h i g n i t i o n O F F .

    NOTE:If the daily auto start function is enabled, the engine will start up

    immediately after ignition is switchedOFF. Use your remote control

    trinket to stop the engine.

    27.Emergency Arming/Disarming1 . F o r e m e r g e n c y a r mi n g : A)Switch ignit ion ON (engine must

    not be started)B)Press button Override 8 timesC)Switch

    igni t ion OFFParking lights will flash 1 time and siren will sound 1

    CHIRP to confirm the functionenabling. 20 sec later the system will

    enable security mode.

    NOTE:If 20 sec after emergency arming any of security zones is

    triggered, the system will alert you with 4 parking light flashes and 4

    siren CHIRPS providing you 20 sec to disarm the car. If disarming does

    not take place, the system will enable alarm mode.

    2 .F or em er g en cy d i s ar mi n g : A)Switch ignition ON (enginemust not be started)B)Press button Override 4 timesC)Switch

    igni t ion OFFParking l ights wil l f lash 2 t imes and si ren wil l

    sound 2 CHIRPS to confirm the fun ct ion enabling.

    NOTE:Remote control trinkets remain functioning after emergency

    arming/disarming

    .

    14

    TOMAHAWK TW-901028.Remote Start-up Preparation for Cars with Manual TransmissionTo ensure capability of remote start-up for cars with manual transmission,

    the gear lever should be in neutral position.Before stopping car engine,

    perform the following procedures:1.Enable car hand-brake (engine

    should be star ted)2.Press but ton , LCD wil l display icon

    ,and a melody will play.Perform step 3 and 4 within 30 sec3.Remove key

    from ignition lock (engine should keep on running)4. Op en th edoo r, get out the car and clo se the doo r If all the steps are

  • 8/12/2019 Tomahawk Tw

    14/30

    performed correct ly, the system will automatically stop the

    engine, if not capability of remote start-up will be disabled.

    29.Programming Auxiliary TrinketsTOMAHAWK TW-9010 provides for recording up to 4 remote control

    trinkets in its memory.To record, perform the following:1.Switchignition ON (engine should not be started)2 . P r e s s a n d h o l d

    b u t t o n

    Override3.Wait for 4 CHIRPS to confirm entry in the trinket

    programming mode4 . R e l e a s e b u t t o n O v e r r i d e 5.Press and

    hold buttons and before you hear siren CHIRPS,

    confirmingmemorization of a new trinket (1 CHIRP for first trinket, 2

    CHIRPS for second trinket, 3CHIRPS for third trinket and 4

    CHIRPS for fourth trinket)

    15

    TOMAHAWK TW-90106.The system will automatically exit the trinket programming

    mode, if it does not receivesignals from the trinket within 6 sec.

    ATTENTION!All un-programmed trinkets will be erased from the memory.

    30.LED Indicator Operation Modes

    The system displays its status using LED indicator when car ignition isswitched OFF.

    S y s t e m

    s t a t u s N u m b

    e r o f

    f l a s h e s 1 . R e m o t e s t a r t - u p

    m o d e a n d I m m o b i l i z e r

    m o d e G l o w i n g

    c o n t i n u o u s l y 2 .C a r

    d i s a

    r m e d

    D i s a

    b l e d

    3 .

    C a r

    a r me d 1

  • 8/12/2019 Tomahawk Tw

    15/30

    f l a

    s h 4 .

    D a i l y

    a u t o

    s t a r tm o d e 2

    f l a s h e s

    5 . A u t o w a r m - u p

    t o s p e c i f i e d

    t e m p e r a t u r e

    m o d e 3 f l a s h e s 6. Daily auto

    start mode and Auto warm-up to specified temperaturemode4

    flashes7 .

    V a l

    e t

    m o d e

    5 f l a

    s h e s

    31.Trinket-pager Battery ReplacementIf battery charge indicator looks like that , it means the battery is low and

    needs promptreplacement.1.O pen tr in ket -p ag er bat te ry

    cover 2 . R e m o v e u s e d b a t t e r y 3 . P r e s sb u t t o n 4 . I n s e r t n e w b a t t e r y 5.Close tr inket -pager

    bat tery cover 6 . P r e s s b u t t o n Battery type: AAA. Alkaline

    batteries are recommended.

    16

    TOMAHAWK TW-9010

    32.Programming ModeTo enter the programming mode, perform the following:1. Switch ignition

    ON (engine should not be started)2. Press button

    Override 6 times3. Switch ignition OFF (6 siren CHIRPS will confirm

    entry in programming mode)Use button Override to select required

    function. Each press means change to the next function.The system will

    indicate selected function with siren CHIRPS:Short CHIRP 1Long

    CHIRP 5

    EXAMPLE:

    14 button Override presses 2 long and 4 short CHIRPS function 14is selected

  • 8/12/2019 Tomahawk Tw

    16/30

    See numbers and descriptions of functions in Programming Table.

    17TOMAHAWK TW-9010

    33.Programming Trinket-pager FunctionsB u t t o n s

    u s e d F u n c t i

    o n s

    p e r f o r m e d N

    o t e s B a c k l i g h t s w i t c h O n D i s a b l e d

    a u t o m a t i c a l l y a f t e r 5 s e c P o w e r

    s a v i n g m o d e s w i t c h O N T r i n k e t - p a g e r

    r e c e i v e r s w i t c h e d OFF automatically 2 min

    after disarmingSound/Vibration mode toggle

    holdClock, alarm-clock and timer setting modeSetting hour/minute

    forward.Hold for fast scrolling.Setting hour/minute backward.Hold for fast

    scrolling.Clock setting mode - hour

    1

    timeClock setting mode - minutes

    2 timesAlarm clock setting mode - hour

    3 timesAlarm clock setting mode - minutes

    4 timesAlarm clock setting modeON/OFF

    5 times

    Timer setting mode - hour

    6 timesTimer setting mode - minutes

    7

    timesTimer setting modeON/OFFAlarm clock setting mode

  • 8/12/2019 Tomahawk Tw

    17/30

    1 timeTimer setting for 10 min

    2 timesTimer setting for 20 min

    3 timesTimer setting for 30 min

    4 timesTimer setting for 60 min

    5 timesTimer setting for 90 min

    6 timesTimer setting for 120 min

    18

    TOMAHAWK TW-9010

    34.Programming Table

    Number of OverridepressesConfirma-tionDescription of function1

    CHIRP

    1

    CHIRPS

    1

    CHIRPS1

    CHIRPS

    1 time

    1 s h o r t

    C H I R P T i m e t o

    s t o p e n g i n e a f t e r

    r e m o t e s t a r t

    ( m i n ) 5 1 0 1 5 2 0

    2 times2 short

    CHIRPS

    Specified engine temperature for automatic warm-up (

    o

    C ) - 5 - 1 0 -

    2 0 - 3 0

    3 times

    3 short CHIRPS

  • 8/12/2019 Tomahawk Tw

    18/30

    S t a r t e r o p e r a t i o n t i m e

    f o r r e m o t e s t a r t - u p

    ( m s e c ) 8 0 0 1 2 0 0 1 8 0 0 3 0 0 0

    4 times

    4 short CHIRPS

    E n g i n e o p e r a t i o n

    c o n t r o l o n

    o r d e r : V e r . 1 V e r . 2 V e r

    . 3

    5 times

    1 l o n g C H I R P T i m e f o r

    e n a b l i n g 2 - n d a u x i l i a r y c h a n n e l

    ( s e c ) 0 . 8 1 0 3 0 c o n s t a n t

    6 times

    1L+1S

    CHIRPS

    S i r e n

    i m p u l s e

    d u r a t i o n

    ( m s e c ) 1 0 0 1 0

    1 5 2 07 times

    1L+2S

    CHIRPS

    C a b l e I G N 2 ( O N / O F F ) / D o o r

    c l o s i n g a t r e m o t e s t a r t -

    u p V e r . 1 V e r . 2 V e r . 3 V e r . 4

    8 times

    1L+3S

    CHIRPSS t a r t e r O N d e l a y b e f o r e

    g a s o l i n e / d i e s e l e n g i n e

    s t a r t ( s e c ) 2 1 0 1 0 1 0

    9 times

    1L+4S

    CHIRPS

    D u r a t i o n o f c e n t r a l l o c k

    o p e n i n g / c l o s i n g i m p u l s e( s e c ) V e r . 1 V e r . 2 V e r . 3 V e r . 4

  • 8/12/2019 Tomahawk Tw

    19/30

    10 times

    2 long

    CHIRPS

    Two-step door opening or 3rd

    auxiliarychannel/immobilizer V e r . 1 V e r . 2V e r . 3 V e r . 4

    11 times

    2L+1S

    CHIRPS

    S a f e d r i v i n g

    f u n c t i o n O F F

    V e r . 1 V e r . 2 V

    e r . 3

    12 times

    2L+2S

    CHIRPS

    A u t o

    a r m i n g V e

    r . 1 V e r . 2

    V e r . 3

    13 times

    2L+3S CHIRPS

    C a b i n

    l i g h t i n g

    d e l a y c o u n t

    ( s e c ) 1 1 5 3 0 4

    5

    14 times

    2L+4S

    CHIRPST i m e f o r c a b i n l i g h t s w i t c h O N / w i n d o w

    r a i s i n g ( s e c ) V e r . 1 V e r . 2 V e r . 3 V e r . 4

    15 times

    3 long

    CHIRPS

    Temperature measurement units/type of locking (black and white

    cable)V e r . 1 V e r . 2 V e r . 3 V

    e r . 416 times

  • 8/12/2019 Tomahawk Tw

    20/30

    3L+1S

    CHIRPS

    T u r b o -

    t i m e r O F

    F 1 m i n 3m i n 6

    m i n

    1 7 t i m e s 3 L + 2 S A n t i -

    h i j a c k i n g O F F V e r .

    1 V e r . 2 V e r . 3

    NOTE:The system confirms selected functions using siren

    CHIRPS

    :

    Llong

    CHIRP

    ,

    Sshort

    CHIRP

    .Function is confirmed using the following siren CHIRPS

    :1

    CHIRP

    ,2

    CHIRPS

    ,3 CHIRPS, 4

    CHIRPS

    ATTENTION!

    Factory settings for programmable functions are underlined.19

    TOMAHAWK TW-9010

    35.Description of Programmable Functions1. Time allotted for engine running after remote start-up: 5/10/15/20

    min.2. Engine temperature when automatic warm-up is switched ON (if

    the function is enabled): -5

    o

    /-10o

  • 8/12/2019 Tomahawk Tw

    21/30

    /-20

    o

    /30

    o

    C.3. Time for starter operation when remote start-up function is enabled:800/1200/1800/3000 ms.Time for the first start-up attempt is specified. If

    first attempt fails, the system will increase timefor each three subsequent

    attempt by 200 msec.

    ATTENTION!Set starter operation time for 3000 msec only when engine operation is

    controlled by tachometer.

    4. Engine operation control versions:Version 1by vehicle network

    voltage.Version 2by oil pressure sensor.Version 3by tachometer.

    ATTENTION!If you choose 3rd version of engine operation control, it is necessary to

    program idle run RPMas follows:1 . D i s c o n n e c t a l l

    p o w e r u s e r s o n t h e v e h i c l e ( s u c h a s

    c o n d i t i o n e r , r a d i o a n d t a p e recorder,

    amplifier).2 . S w i t c h i g n i t i o n O N

    a n d p r e s s b u t t o n O V E R R I D E

    9 t i m e s . 3 . S w i t c h i g n i t i o n

    O F F . S i r e n w i l l s o u n d 9 C H I R P S a n d L E D w i l l g i v e

    9 flashes. Wait for the LED to glow.4 . S t a r t

    e n g i n e w i t h i g n i t i o n

    k e y . 5 . A f t e r e n g i n e s p e e d

    r e a c h e s 5 0 0 - 1 5 0 0 R P M a n d

    t h e e n g i n e i s w a r m e d enough, go to the

    next step.6 . P r e s s a n d h o l d b u t t o n

    O V E R R I D E 1 t i m e . I f t h e p r o c e d u r e

    i s s u c c e s s f u l , t h e system will sound 1 CHIRP,otherwise it will alert with 4 CHIRPS of the necessity to repeat

    the procedure.

    20

    TOMAHAWK TW-90105. Enabling impulse length for 2nd auxiliary channel: 0.8/10/30/constant.6.

    Siren impulse (klaxon) duration: 100/10/15/20 msec.7. Wire IGN 2

    ON/OFF (see wiring diagram) and door auto closing at remote start-

    up:Version 1IGN 2 ON, locks do not close automatically at remotestart-up;Version 2IGN 2 OFF, locks do not close automatically at

  • 8/12/2019 Tomahawk Tw

    22/30

    remote start-up;Version 3IGN 2 ON, locks close automatically at

    remote start-up;Version 4IGN 2 OFF, locks close automatically at

    remote start-up.8. Starter switch-on delay before remote engine start-up:2

    sec - for gasoline engines10 secfor diesel engines9. Enabling impulse

    length for central lock:Version 1Closing impulse0.8 sec, openingimpulse0.8 sec;Version 2Closing impulse3.6 sec, opening impulse

    3.6 sec;Version 3Closing impulse0.8 sec, 2 opening impulses0.8

    sec;Version 4Closing impulse30 sec, opening impulse0.8 sec;10.

    Choice of functions: 3rd auxiliary channel or two-step door

    opening/immobilizer:Version 13rd auxiliary channel, immobilizer

    OFF;Version 2Two-step door opening, immobilizer OFF;Version 3

    3rd auxiliary channel, immobilizer ON;Version 4Two-step door

    opening, immobilizer ON.11.Safe driving function:Version 1Doors

    do not close and are automatically open after ignition ON and

    OFFrespectively.

    21

    TOMAHAWK TW-9010Version 2 Doors are automatical ly locked 10 sec af ter

    ig ni ti on ON and op en immediately after ignition OFF.V e r s i o n 3

    D o o r s a r e a u t o m a t i c a l l y l o c k e d 3 0 s e c a f t e r i g n i t i o n

    O N a n d o p e n immediately after ignition OFF.12. Auto arming.Version

    1OFF;Version 2ON without locking doorsVersion 3ON withlocking doors13. Cabin lighting delay count. The system will secure doors

    after the specified period (1 sec/15sec/30 sec/45 sec) after pressing button

    .14.Time for c losing windows after vehicle arming or

    sw it ch in g cabi n li gh ti ng ON af te r disarming.Version 1

    Switching cabin lighting ON for 20 sec after disarmingVersion 2

    Switching cabin lighting ON for 30 sec after disarmingVersion 3Closing

    windows 20 sec after armingVersion 4Closing windows 30 sec after

    arming15.Selection of cabin temperature measurement units

    displayed on trinket-pager:o

    C or

    o

    F /engine auxiliary blocking type (black and white cable).Version 1

    Measurement units

    o

    C, auxiliary blocking normally openVersion 2Measurement units

    oF, auxiliary blocking normally closedVersion 3Measurement units

  • 8/12/2019 Tomahawk Tw

    23/30

    o

    C, auxiliary blocking normally closedVersion 4Measurement units

    o

    F, auxiliary blocking normally open

    16.Turbo timer function.17.Selection of ANTI-HIJACK ANTI-HIJACK OFFVersion 1:

    : ACC ON, press mute button 2 seconds to enter into ant-hijacking

    .Version 2. when: ACC ON,a) press mute button 2 seconds to enter into

    anti-hijacking b) when door is open, close door, system enter into anti-

    jackingVersion 3:A) turn ACC OFFON , system enter into anti-

    hijacking automaticallyB) ACC ON, press mute button to enter into ani-

    hijack.C)ACC ON, open the door, and then close the door, system enter

    into anti-hijiacking

    4444444

    22

    TOMAHAWK TW-9010

    INSTRUCTIONS FOR INSTALLATION1.Basic Installation

    Principles TOMAHAWK TW-9010 vehicle alarm system has a classic

    connection arrangement. First of all , before installation disable

    vehicle power system (disconnect batteryterminal). To choose

    placesfor alarm system units, follow the principles as below:- S e c r e c yo f i n s t a l l a t i o n - Ab sen ce o f h eat an d mo is tu re emi tt in g

    sources near the units-Allow for minimal mutual interference

    between standard vehicle electronics and alarm un its

    ATTENTION!Emitting antenna should be installed at a distance from alarm and vehicle

    control units. Try to minimizelength of cables.

    2.Choosing Locations for Main Units 1) An electronic unit for alarm control is installed inside the cabin

    (passenger compartment). Toachieve maximum range, combinedRF antenna for the cabinet should be placed at the highest point,

    without contact with metal parts and electric wires.2) Siren is installed in

    the engine compartment, at a hard-to-reach place. If you use an

    independentsiren, ensure access to service key slot. The siren

    should be installed with horn down to escapemoisture entry. Wire

    connections should better be done inside cabin for less corrosion.3) All

    strong current circuits (power supply, lights, central lock, etc.)

    should be protected withrespectively rated safety fuses.4) Hood andboot triggers are cut in places protected against moisture,

  • 8/12/2019 Tomahawk Tw

    24/30

    inaccessible with hood and boot closed. Triggers should be oiled

    periodically to avoid jams and corrosion.5) The shock sensor is installed in

    the cabin, an ideal place might be the vehicle centre, and securedto the car

    body metal with self-driving screws or pasted.6) It is recommended to

    solder contacts in connections of ignition, starter and other circuits.23

    TOMAHAWK TW-9010

    3 . W i r e C o n n e c t i o n s

    6 PIN Remote Start-up Power Socket

    1 . B l a c k a n d y e l l o w w i r e starter switch-on wire (+12V).This is an output signal +12V to starting

    relay.It is connected to ignition lock wire where +12V appears in

    the Starter key position. Thissignal is for engine start-up. Connect

    this wire to blocking relay.

    2 . B l u e w i r e An output signal +12V ACCauxiliary equipment.It is connected to

    ignition lock wire where +12V appears in the ACC and

    Ignition ON keyposition.

    3 . T h i n r e d w i r e system power supply wire (+12V)It is connected to ignition battery +

    terminal via 10A fuse.4 . T h i c k r e d w i r e

    remote start-up circuit power supply wire (+12V)It is connected to

    ignition battery + terminal via 40A fuse.

    5 . Y e l l o w w i r e IGN 1 wire, output signal +12V.It is connected to ignition lock wire

    where +12V appears in the Ignition ON key position anddoes not

    disappear in the Starter position.

    6 . G r e e n w i r e

    - IGN 2 wire, output signal +12V.It is connected to ignition lock wirewhere +12V appears in the Ignition ON key position anddisappears in

    the Starter position, if this wire is available on the vehicle

    where the system isinstalled.

    24

    TOMAHAWK TW-9010

    6 PIN Remote Start-up Power Socket

    1. Blue wire

    central contact for central lock opening relay2. Blue and grey wire

  • 8/12/2019 Tomahawk Tw

    25/30

    normally open contact for central lock opening relay

    3. Blue and black wirenormally closed contact for central lock opening relay

    4. Green wire

    - central contact for central lock closing relay5. Green and grey wire

    normally open contact for central lock closing relay

    6.

    Green and back wirenormally closed contact for central lock closing relay

    18 PIN Main Socket

    1. Black wire

    system -(Ensure reliable contact)

    2. Blue wire

    wire for cabin light ON or window UP- 300mA when disarming / arming

    system (programmable)

    3. Black and red wireIGN 3 output- 300mA while remote start-up procedure, for arrangement of

    auxiliary ignitioncircuits. This wire may become necessary, if ignition lock

    of vehicle where the system isinstalled has more than two ignition circuits,

    or for enabling immobilizer by-pass modules.4 . B l a c k a n d y e l l o w w i r e

    starter lock relay wire.- 300mA after arming system and/or remote

    start-up procedure and/or in Anti-hijackmode.

    ATTENTION!Blocking relay should only be used for blocking starter to prevent engine

    stop while movement.

    25

    TOMAHAWK TW-90105 . Y e l l o w a n d r e d w i r e

    2nd auxiliary channel wire (-300mA).

    6 . G r e y a n d b l a c k w i r e

    input for tachometer wire or oil pressure sensor.Connect to tachometer

    signal wire or oil pressure sensor wire (programmable).

    7 . B l u e a n d r e d w i r e + input for door sensor.

    8 . O r a n g e a n d w h i t e w i r e - - input for boot sensor.

  • 8/12/2019 Tomahawk Tw

    26/30

    9 . V i o l e t w i r e - Anti-hijack function switch ON wire.

    Anti-hijack function is switched ON when - appears on this wire.

    10.Green and black wireparking lights power supply wire.It is connected via

    7.5A fuse.

    11.Green and yellow wire

    parking lights power supply wire.It is connected via

    7.5A fuse.

    12.Black and white wire

    programmable auxiliary blocking (normally closed/normally

    open).300mA (programmable).

    13.Grey wire

    siren output(1.5A)

    1 4 . Y e l l o w a n d b l u e w i r e 3rd auxi l iary channel wire or two-step door opening

    wire(programmable).A)3rd auxiliary channel - 300mA.B)Two-

    step door opening - 300mA.

    15.Yellow and black wirewire for

    remote boot opening.(- 300mA, 1 sec)

    26

    TOMAHAWK TW-9010

    16.Orange and violet wire

    hand brake wire.It is connected to - hand-brake switch (for

    manual transmission) or to stop lights (for automatic transmission)

    (see diagrams 8,9) depending on car bundling.17.Blue and black wire

    - input for door sensor.

    18.Orange and grey wire -- input for hood sensor.

    4 PIN shock sensor socket

    Socket for shock sensor.

    2 PIN Override button socket

    Socket for button Override.2 PIN LED indicator socket

  • 8/12/2019 Tomahawk Tw

    27/30

    Socket for LED indicator.

    5 PIN combined antenna socket

    Socket for combined antenna.

    4. Selection of Automatic or Manual Transmission

    Selection of automatic or manual transmission in TOMAHAWK TW-9010is done using jumper 1 (see wiring diagram).

    Jumper closedautomatic transmission

    Jumper openmanual transmission

    TOMAHAWK TW-9010

    27

    TOMAHAWK TW-9010

    5.Connection of Central LockTOMAHAWK TW-9010 has in-built power relays for central lock control.

    Wiring for connection of central lock is made in a separate six-pin socket.

    Wire colours and wiring diagramsare shown in diagrams 1-4.

    ATTENTION!Please note that impulse duration for central lock control is a

    programmable function.

    6 . S e t t i n g S h o c k S e n s o r

    Setting is the last installation stage of TOMAHAWK TW-9010 alarm

    system. Set shock sensor sensitivity to minimum. Gradually increase

    sensitivity and knock the car body with your palm tocheck

    triggering threshold.

    ATTENTION!Excess sensitivity may result in a great number of false trigger

    actions; you will be forced to desensitizesensors.

    28

    TOMAHAWK TW-9010Wire ConnectionsFig. 4

    29

    TOMAHAWK TW-9010

    6 PIN Remote Start-up Power SocketDiagram 1

    ATTENTION!Connect blocking relay socket according to diode polarity shown in

    diagram 1.Ignition key position

  • 8/12/2019 Tomahawk Tw

    28/30

    WireO f f A C C

    I g n i t i o

    n S t a r t System power

    supply wireStarter wireIGN 1 wireACC wireIGN 2 wirePower circuit

    supply wireIGN 3 wire30

    TOMAHAWK TW-9010

    6 PIN central lock connection socket18 PIN main socketDiagram 2

    31

    TOMAHAWK TW-9010

    4 PIN shock sensor socket2 PIN Override button socket2 PIN LED indicator

    socket5 PIN combined antenna socketDiagram 3

    32

    TOMAHAWK TW-9010

    Connection of auxiliary electric driveControl time 0.8 secDiagram 4

    Central lock positive controlControl time 0.8 secDiagram 5

    33

    TOMAHAWK TW-9010Central lock negative controlControl time 0.8 secDiagram 6

    Pneumatic central lock (Audi, Mercedes)Control time 3.6 secDiagram 7

    34

    TOMAHAWK TW-9010Diagram 8Diagram 9

    35

    TOMAHAWK TW-9010Diagram 10

    36

    TOMAHAWK TW-9010

    Engineering dataR a t e d

    v o l t a g e + 1 2 V C u r

    r e n t c o n s u m p t i o n 1 5 m A

    Allowable current:6 PIN remote start-up power socket

  • 8/12/2019 Tomahawk Tw

    29/30

    I n p o w e r s u p p l y c i r c u i t t h i c k r e d

    w i r e 3 0 A (limited with fuse)I n p o w e r s u p p l y

    c i r c u i t t h i n r e d w i r e 1 0 A (limited with

    fuse)I G N

    1 , + 3

    0 A (yellow

    wire)I G N

    2 ,

    + 3

    0 A (green

    wire)I G N

    3 , -

    3 0 0 m

    A (black and red

    wire)S t a r t e r

    w i r e ,

    + 3 0 A (black and yellow

    wire)

    6 PIN central lock connection socket

    In contact relay circuitf o r

    c e n t r a l l o c kc o n t r o l 2 0 A (limited with fuse)

    37

    TOMAHAWK TW-9010

    18 PIN main socket

    B l o c k i n g r e l a y

    c o n t a c t s 4 0 A B l o c k i

    n g r e l a y s e r v i c e o u t p u t , -

    3 0 0 m A (black and yellow wire)S i r e n

    p o w e r o u t p u t , + 2 A (grey wire)A u x i l i a r y

    c h a n n e l 1 o u t p u t , -

    3 0 0 m A (yellow and black wire)A u x i l i a r y

    c h a n n e l 2 o u t p u t , -

    3 0 0 m A (yellow and red wire)A u x i l i a r y

    c h a n n e l 3 o u t p u t , -

    3 0 0 m A (yellow and blue wire)S i z e l i g h t s

    p o w e r s u p p l y o u t p u t s , + 7 . 5 A (green-black andgreen-yellow wires,limited with fuses)O u t p u t

  • 8/12/2019 Tomahawk Tw

    30/30

    t o c a b i n l i g h t ,

    - 3 0 0 m A (blue wire)

    Temporary intervals:Service output, - permanently armed(black and yellow

    wire)A u x i l i a r y c h a n n e l 1o u t p u t , - 1 s e c (yellow and black wire)

    38

    TOMAHAWK TW-9010

    A u x i l i a r y c h a n n e l 2

    o u t p u t , - 0 . 8

    s e c ( p r o g r a m

    m a b l e ) 1 0

    s e c ( y e l l o w

    a n d r e d

    w i r e ) 3 0

    s e c PermanentlyA u x i l i a r y

    c h a n n e l 3 o u t p u t , - 0 . 8

    s e c (yellow and blue wire)Impulse duration

    for c e n t r a l l o c k

    c o n t r o l 0 . 8

    s e c ( p r o g r am m a b l e ) 3 .

    6 s e c 30 secThis device meets weather

    requirements under GOST 15150for UHL 2 version (installation inside

    cabin).This device meets electric compatibility requirements under GOST

    R50789-95.Made in Taiwan

    39