TMR 48 Analog Timers• Multi-function or monofunction
• Multi-timing ranges from 0.02 Sec to 300 Hrs
• Multi voltage from 12-240 Vdc / 24-240 Vac
• Time setting displayed on dial
• 2 output relays 5A / 250 Vac
• 2 LED indicators 1 for power and 1 for relay status
Type Functions Output Supply Voltage Part NumberTMR 48 U A, B, C, W, Ac, Bw 2 SPDT relays, 11 pin plug in 5A / 250 Vac 12 - 250 Vdc 88 886 016
24 - 240 VacTMR 48 A A 2 SPDT relays, 8 pin plug in 5A / 250 Vac 12 - 250 Vdc 88 886 106
24 - 240 VacTMR 48 X A1, A2, H1, H2, Q1, Q2, D-Di 2 SPDT relays, 8 pin plug in 5A / 250 Vac 12 - 250 Vdc 88 886 116
2 timed or 1 timed & 1 instantaneous 24 - 240 VacTMR 48 L L, Li, G, Gi 2 SPDT relays, 11 pin plug in 5A / 250 Vac 12 - 250 Vdc 88 886 516
24 - 240 Vac
General SpecificationsSupply Voltage Un 12 - 250 Vdc
24 - 240 VacOperating Range +/- 10% DC Supply
-15% / +10% AC SupplyFrequency 50 / 60 HzPower Consumption 4.8 VA / 230 Vac
2.5 VA / 110 Vac1.1 VA / 24 Vac0.5 W / 24 Vdc0.8 W / 12 Vdc
14 Timing Ranges Available 0.02 - 1.2 s 0.2 - 12 m 0.2 - 12 H0.05 - 3 s 0.5 - 3 m 0.3 - 5 H0.2 - 1.2 s 2 - 12 m 2 - 12 H0.5 - 30 s 5 - 300 m 5 - 300 H2 - 120 s5 - 300 s
Repetition Accuracy +/- 0.5% of full scale at 25°C (typical with constant parameters)Temperature drift according to IEC / EN 61812 +/- 0.05% of full scaleDisplay Accuracy +/-5% of full scale at 25°CMinimum required START pulse duration 25msMinimum required GATE pulse duration 60msMinimum required RESET pulse duration 60msMinimum required START pulse duration 50ms
Output SpecificationsNominal Rating 2 x 5ANominal insulation voltage 250VacRated power (resistive load) 2000VAMinimum Current 10mAElectrical life at max / Vac resistive (# of operations) 105
Mechanical Life 30 x 106
Function & UseDisplay of output state by 2 LED’s Green : Power ON, Flashing during timing
Yellow : On output ON, OFF output OFFOperating Temperature range -20 to +55°CStorage Temperature range -40 to +70°CBreakdown Voltage 2 KVProtection Class (IEC 60529) - Panel Mounted IP 50Protection Class (IEC 60529) - Casing IP40Housing Material Self extinguishingWeight (g) 140
Elmatik AS, Türi 9, 11314 Tallinn Estonia tel. +372 650 3875 tel. +372 650 3876 fax +372 655 8019 e-mail: [email protected]
TIMERS TIMERS
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
2/23
2
Dimensions
Connections
TMR 48 Covers
35 mm DIN rail base with clips 79 237 739 Panel cut-out TMR 48 U / A / X / L
24.2
38
52 357.8
5
1.5
3.5
6.4
68.2
7
B 31 4 3
8 1 2
34
6 5 4 3
32 12 14
1.1
153.5
18.5
30
1
45
45
44.4
39
15.596.8 48 64.56.8
48
TMR 48 U
Decorative CoversColor Part NumbersBlack 79 237 783Grey 79 237 784Other colors available by special order.
3
2 101 11
R1
Gate
Start
Reset
9
845 76
U
-~
+~
R2
Time Function CurvesFunction A (TMR 48 A)Delay on make (delay on energisation)
T T
R2 ( )
R1 ( )
5 6 8
1 3 4
2 7U ( )
Function H1Timing on energisation – interval
T T
R2 ( )
R1 ( )
5 6 8
1 3 4
U ( )2 7
Gate
3
101 11
R19
845 76
7262
2
-
U +~
R2
off starton start
LG
TMR 48 A/X
4
3
2R1
U
7
6
5
1 8
-~
+~
R2
TMR 48 L
Function A1Delay on make (delay on energisation)
T T
R2 ( )
R1 ( )
5 6 8
1 3 4
2 7U ( )
Function H2Timing on energisation – interval
T T
R2 ( )
R1 ( )
5 6 8
1 3 4
U ( )2 7
Function A2Delay on make (delay on energisation)
T T
R2 ( )
R1 ( )
5 6 8
1 3 4
2 7U ( )
Function Q1Star-delta
U ( )
R2 ( )
R1 ( )
T Ti T Ti
5 6 8
1 3
2 7
4
T
Elmatik AS, Türi 9, 11314 Tallinn Estonia tel. +372 650 3875 tel. +372 650 3876 fax +372 655 8019 e-mail: [email protected]
TIMERS TIMERS
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
2/24
Function Q2Star-delta 2
T Ti TT Ti
R2 ( )
R1 ( )
5 6 8
1 3 4
2 7U ( )
Function A (TMR 48U)Delay on make (delay on energisation)
t1 t2T TT= t1+t2
T T T T
U ( )2 10
Start ( )2 6
Gate ( )2 5
Reset ( )2 7
R1 ( )31 4
R2 ( )98 11
Function BTiming on impulse : single shot
U
Start
Gate
Reset
t1 t2T= t1+t2
T T T T T
R2 ( )8 9 11
R1 ( )1 3 4
2 10
2 6
2 5
2 7
T
Function D-DiCyclic timing : repeat cycle : symetric recycler
TT T T
R2 ( )
R1 ( )
5 6 8
1 3 4
U ( )2 7
Function CTiming after impulse - Delay on break - Delay off w/constant supply
�t1 t2T=t1+t2
TT T T
U ( )2 10
Start ( )2 6
Gate ( )2 5
Reset ( )2 7
R1 ( )31 4
R2 ( )98 11
Function WTiming after impulse on control contact
t1 t2T=t1+t2
TT T T
U ( )2 10
Start ( )2 6
Gate ( )2 5
Reset ( )2 7
R1 ( )31 4
R2 ( )98 11
Function GCyclic function
t1 t2t3 t4
T = t1+t2
T
P
TT
P P
T
P
P = t1+t3+t4
U ( )2 10
Start ( )2 6
Gate ( )2 5
Reset ( )2 7
R1 ( )31 4
R2 ( )98 11
Function BwPulse output (adjustable)
t1 t2 t1�
t2
T=t1+t2 T=t1+t2
TTT T T
U ( )2 10
Start ( )2 6
Gate ( )2 5
Reset ( )2 7
R1 ( )31 4
R2 ( )98 11
Function L/Li - G/GiCyclic timing : asymetrical recycler
L Li G Gi
PP TT t4t3t4
Ton Ton
Toff Tofft1 t2 t1 t1 t1t2 t2 t1 t2t3
t1 t2 Toff Toff
Ton Ton
Toff =
Ton Ton Ton Tont2
Ton =t1+t2 t1+t2
Ton = t3+t4Ton =Toff =t1+t2 t1+t2 P=t1+t2+t4
Ton = t1+t2P=t1+t2+t3+t4
U ( )2 10
Gate ( )2 5
OFF start / ON start ( )2 6
L /G ( )2 7
R1 ( )31 4
R2 ( )98 11
Function AcTiming after closing and opening of control contact
t1 t2T=t1+t2
t1 t2T=t1+t2
T T T T T T T
U ( )2 10
Start ( )2 6
Gate ( )2 5
Reset ( )2 7
R1 ( )31 4
R2 ( )98 11
Elmatik AS, Türi 9, 11314 Tallinn Estonia tel. +372 650 3875 tel. +372 650 3876 fax +372 655 8019 e-mail: [email protected]