Upload
lynhi
View
241
Download
0
Embed Size (px)
Citation preview
Tmax T5 UL 600A DOC. N.° 1SDH000437R0003 - L2484
1
240
240
2
39,
44"
9,44
"
2 Nm
OFF TRIPPED
CLACK
ON
17 lb in
Usare cavi o barreisolate o eseguireprove di tipospecifiche sull'installazione.
Use cable orinsulated busbars orperform specific typetest on theinstallation.
42 Nm
17 lb in
TRIPTEST
PRESET
READY
SACETT1
+-
POLARITY
TRIPTEST
PRESET
THEBREAKER
TRIP
READY
THIS TEST CAUSES
SACETT1
+-
POLARITY
8
t
I
L
t1
I
I3I1
I
t
I
L
I3I1
t
I
L
t2
I2I1
S
t1
Tmax
T5V400
LR54280
E93565
Made inIta
ly by ABBSACE
IEC
60947-2Ratin
gs
LISTED
CIRCUIT
BREAKER
ISSUE
NO. N0000
TYPET5V
600 V
50/60 Hz
40°C
3 POLEUNIT
UL489/CSA
C22.2-5
600 V
85,000 A
480 V
150,000 A
INTERRUPTIN
GRATIN
GS Ics (%)Icu (kA)Ue (V)
230
415
690
750
300
100
200
80
70
100
100
100
Tmax
T5V400
LR54280
E93565
LISTEDCIRCUIT
BREAKER
UL489/CSAC22.2-5
600 V
85,000 A
480 V
150,000 A
INTERRUPTINGRATINGS
ISSUENO. N0000
TYPET5V
600 V
-50/60 Hz
40°C
3 POLEUNIT
Made in Italy by ABB SACE
2 POLES500 VDC
3 POLES501 TO
600 VDC
DCW
IRINGDIAGRAM
SUNGROUNDED
SYSTEMONLY
IEC60947-2 Ratings
Ics (%)
Icu (kA)
Ue (V)230
415
690
750
300100
200
80
70100
100
100
TERMINATION
VALUES
CU/AL 75°CONLY
HACRType
WIRE
RANGE
1/0-14AWG
300Kcmil-4AW
G WIRE
TORQUE
50 lb-in200 lb-in
CAT. NO.
1SDA053694R1 / K5TGR-4
300Kcmil-4AW
G
200 lb-in
MOS
AUX
UVR
SOR
250 V- 5 A
250 V250 V
250 V- 5 A
Ue=690 V
Ui=1000 V
Uimp=
8kV
1SDA053694R1 / K5TGR-4
1SDA053694R1 / K5TGR-4
Tmax T5V 400
LR54280
E93565
Made in Italy by ABB SACE
IEC 60947-2 Ratings
LISTED CIRCUITBREAKER
ISSUE NO. N0000TYPE T5V
600 V 50/60 Hz40°C
3 POLE UNIT UL489/CSA C22.2-5
600 V 85,000 A480 V 150,000 A
INTERRUPTING RATINGS
Ics (%)
Icu (kA)
Ue (V) 230 415 690 750
300
100
200 80 70
100100100
PR221DS
1
CLACK
Esempio:Example:
Esempio:Example:
Esempio:Example:
In = 600 AI1 = 600 x (0,4+0,08+0,32)= 480At1= 12 s @2880 A (6I1)
In = 600 AI3 = 600 x (1,5+2)=2100A
I2=OFFEsempio:Example:Ne=ON ; 50%
In = 600AI2 = 600 x (1,5+2)=2100At2= 0,1 s @4800 A (8In)
I3=OFF
ABB SACE S.p.a.Via Baioni, 3524123 Bergamo ItalyTel. +39 035 395.111 - Telefax +39 035 395.306-433
http://www.abb.com
1
2
34
CLACK
6 165101,5/4"
205
102,
5
162
65,5/2,58"
<2
420
X
X
X X XXX
Y
116
Y
Y
139/5,47"
_
F - FC Cu Al81
124
105
46,5/1,83"
2,7 5,5
>4_
59,5
176/
6,39
"
Y
642
1/0,04" 107/4,21"
ø5,5/ø0,22"
4,04
"
8,07
" 0,1" 0,21"
4,88
"
6.38
"
3,19
"
18,1
9"
16,5
4"
4,57
"
2,34
"
<0,08"_
>0,16"_
4,13
"
9
Preset-ready
Trip
TRIP TEST
2
5A C D
CON MOSTRINAWITH FLANGE
1074,21"
64,52,53"
SENZA MOSTRINAWITHOUT FLANGE
1074,21"
60,52,38"
B
1154,52"
FIS
SO
FIX
ED
117
138
76
C
D
B
A
Y
Y
X X X X
Y
Y
= =
OPTIONAL4,60"
2,99
"
5,43
"
1074,21"
1154,52"
1074,21"
6,5" 7
2 Nm
31 Nm17 lb in
274 lb in
250-500 Kcmil
F - FC CuAl
139,55,49"
57,752,27"
57,752,27"