Mechanical Specifications
Electrical Characteristics
Temperature Characteristics
External Dimensions
Weight
Solar Cells
Front Glass
Frame
Junction Box
Output Cables
Connector
Mechanical Load
1674x 992x 35 mm
18.5kg
Poly crystalline
3.2 mm AR coating tempered glass, low iron
Anodized aluminium alloy
IP67
4.0 mm²,cable length: 900 mm
MC4 Compatible
5400 Pa
-0.38 %/°C
-0.30 %/°C
+0.05 %/°C
-40~+85 °C
45±2 °C
I-V Curve (SRP-280-BPB(-HV))
I
9
14
R4.5
5:1
70 70
7070
II2:1
35
53
Section A-A10:1
Add: No.1-2, HengyaoRd, HenglinTown, Wujin District, 213000, Changzhou, China Tel: +86-519-69699879 Fax: +86-519-88786181 Email: [email protected]
992±1
1674
±1
SERIAL NUMBER
Cuts Night, Breaks Dawn.
TM
TM
Cuts Night, Breaks Dawn.
275W-290W
Packing Configuration
Pieces per Pallet Pallets per Container
Pieces per Container
Container 20’GP 40’GP
12
360
26
780
3030
1674x 992x 35 mm
STC: lrradiance 1000 W/m² module temperature 25°C AM=1.5;
(0,+4.99)
1000 VDC / 1500 VDC
20A
SRP-275-BPB SRP-275-BPB-HV
SRP-280-BPBSRP-280-BPB-HV
SRP-285-BPBSRP-285-BPB-HV
SRP-290-BPB SRP-290-BPB-HV
Maximum Power at STC (Pmp)
Open Circuit Voltage (Voc)
Short Circuit Current (Isc)
Maximum Power Voltage (Vmp)
Maximum Power Current (Imp)
Module Efficiency at STC(ηm)
Power Tolerance
Maximum System Voltage
Maximum Series Fuse Rating
Module Type
STC
275
38.0
9.14
31.8
8.65
STC
280
38.2
9.24
32.0
8.75
STC
290
38.8
9.39
32.6
8.90
16.56 16.86
STC
285
38.5
9.32
32.3
8.83
17.16 17.46
942±1
A A
Grounding holes2×Ø
Mounting holes
992±1
1674±1
1394±1
894±
1
I
Ⅱ
10±1
35±1
SE
RIA
L N
UM
BE
R
SERIAL NUMBER
Label
200±
5
200±5
Junction Box
SERIAL NUMBER
positive ( + )negative ( - )
BOX BOX
+
BOX
-
900
900
Voltage [V]
Cur
rent
[A]
Voltage [V]
Cur
rent
[A]
0 5 10 15 20 25 30 35 400
2
4
6
8
10
12
Incident Irrad. = 1000 W/m2
Cells temp. = 25 °C
Incident Irrad. = 800 W/m2
Incident Irrad. = 600 W/m2
Incident Irrad. = 400 W/m2
Incident Irrad. = 200 W/m2
0 10 20 30 40 500
2
4
6
8
10
Incident Irrad. = 1000 W/m2
Cells temp. = 10 °CCells temp. = 25 °CCells temp. = 40 °CCells temp. = 55 °CCells temp. = 70 °C
-HV
SRP-XXX-BPB: Maximum System Voltage1000 VDC
SRP-XXX-BPB-HV: Maximum System Voltage1500 VDC
Seraphim’s Blade™ Series solar module boasts two identical parts, which are composed of cells that are half the size of ordinary solar cells. By cutting cells into halves, these smaller currents will help reduce “Cell To Module” loss, which means higher output.
In the meantime, the overall space between cells are doubled, and more light will be transferred into power through multiple reflections. Compared to mainstream standard modules, the Blade™ series module has lower current and series resistance which helps minimize mismatch loss, internal power loss, and shadow effect, etc. Once one cell has EL defect or appearance defect, such as black edge or V sharp. After cutting, one intact half can be reused.
Instead of 6 internal strings of cells, the Blade series module has 2 x 6 shorter ones. This design effectively deals with the mismatchhappened between cells caused by shadow, out of sync performance degradation, ect.
SRP-DS-EN-2019V1.0 | © Copyright 2018 Seraphim
Blade™ – A Module re-Modeled
Less Mismatch Loss
More Output Higher ROIHigher Efficiency
With 6 internal strings of cells
With 2 x 6 internal strings of cells
Module current output is 8.7A, current mismatch in series is 0.3A.
Module current output is 4.5+4.35=8.75A, current mismatch in series is 0.15A.
Blade™
Standard Module
Design Sketch
Design Sketch
Circuit Diagram
Circuit Diagram
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.5A
4.5A 4.5A 4.5A 4.5A 4.5A 4.35A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 8.7A
Cuts Night, Breaks Dawn.
TM
Cuts Night, Breaks Dawn.
TM
Electrical Mismatch
Electrical Mismatch
Less Internal Power Loss
By cutting solar cell into halves, the internal power loss will be lower and hot spot effect will also be reduced.
The ribbon length of half-cell is shorter than normal cell. Calculated by Joule's law and Ohm' law, the power loss reduction is nearly 6%.
Standard Cell Half Cell
Higher Yield Due to Better Shading ResponseBlade™ comprises two separated and identical solar cell arrays, which means the ordinary strings of cells are cut into halves, and these shorter strings compose arrays which has separated current paths. When a module is shaded, only one side shaded array's current will be impacted, while the other array will still be functionally producing power. Under this circumstance, when a module is shaded, the affected working areas of Blade™ will be 50% less.
Blade Module Standard Module TM
Warranty
linear power output warranty
Guarantee on productmaterial and workmanship
10YEARS
25YEARS
Gua
rant
eed
Pow
er
100%97.5% 97.5%
94.7%
91.2%
87.7%
84.2%
80.7%
90%
80%
0 5 10 15 20 25Years
Addtional Value from Linear Warranty
Cut
Insurance
Product Certificates