    LenovoSystemx3850X6(6241) 1

    Lenovo System x3850 X6 (6241)Lenovo Press Product Guide

    TheLenovoSystemx3850X6server,machinetype6241,isafour-socket4Urack-mountedserverthatrepresentsthesixthgenerationoftheEnterpriseX-Architecture.Itdeliversfastapplicationperformance,isbasedonanagilesystemdesign,andisaresilientplatformthatisneededformission-criticaldatabases,enterpriseapplications,andvirtualizedenvironments.

    Thex3850X6packsnumerousfault-tolerantandhigh-availabilityfeaturesintoahigh-density,4Urack-optimizedlid-lesspackagethathelpsreducethespacethatisneededtosupportmassivenetworkcomputingoperationsandsimplifyservicing.Thex3850X6supportsuptofourIntelXeonE7v3andv2

    high-performanceprocessorsandupto6TBofmemory.

    Suggesteduse :mission-criticalscalabledatabases,businessanalytics,virtualization,enterpriseapplications,andcloudapplications.

    ThefollowingfigureshowstheLenovoSystemx3850X6.

    Figure1.LenovoSystemx3850X6,machinetype6241

    Did you know?

    Thex3850X6serveremploysalid-lessdesignwhereallserviceablecomponentsarefront-andrear-accessible.Inaddition,eachmajorsubsystemisimplementedasmodular"book"design,suchastheComputeBooksandI/OBooks.Thisconfigurationmeansthatcomponentsareeasytoupgradeandservice,whichtranslatestogreateruptimeofapplicationstoyourusers.Thex3850X6offersenterprisescalabilityandadvancedRASfeaturestosupportthemostdemandingmission-criticalapplicationsthatrequire24x7operations.

  • 8/9/2019 Tips 1250

    2/59

    LenovoSystemx3850X6(6241) 2

    Key features

    Theincreasingdemandforcloud-computingandanalyticsworkloadsbyenterprisestomeetsocial,mobile,andBigDatarequirementsdrivesinnovationtofindnewwaystobuildinformationalsystems.Clientsarelookingforcost-optimizedfit-for-purposeITsolutionsthatmanagelargeamountsofdata,easilyscaleperformance,andprovideenterpriseclassreliability.

    Builtondecadesofinnovation,LenovointroducesthesixthgenerationofEnterpriseX-Architecturetechnology,LenovoX6servers.LenovoX6serversarefast,agile,andresilient:

    Fastapplicationperformancemeansimmediateaccesstoactionableinformation.

     Agilesystemdesignhelpstoreduceacquisitioncostsandprovidetheabilitytoupgradeprocessorandmemorytechnologyateachrefreshwithinthesamechassis.

    Resilientplatformsmaximizeapplicationuptimeandpromoteeasyintegrationinvirtualenvironments.

    LenovoX6serverscontinuetoleadthewayastheshifttowardmission-criticalscalabledatabases,businessanalytics,virtualization,enterpriseapplications,andcloud-computingapplicationsaccelerates.

    Fast appl ication performance

    Theserveroffernumerousfeaturestoboostperformance:

    SupportsLenovomemory-channelstorage(eXFlashDIMMs),wheresolid-statestoragedevicesareinstalledinmemoryDIMMsockets.Thesedevicesaredirectlyconnectedtotheprocessorsandprovidethelowestlatencyvaluesintheindustry.

    BasedontheIntelXeonE7familyofprocessors:

    ModelsbasedonE7-4800v3andE7-8800v3processors;E7-4800v2andE7-8800v2oprocessorsalsoavailable

    SupportsuptofourE7v3processorswithatotalof72coresand144threadstomaximizetheo

    concurrentrunningofmulti-threadedapplications.Improvesproductivitybyofferingsuperiorsystemperformancewithprocessorsupto18coresoandcorefrequenciesupto3.2GHzcorespeeds,andupto45MBofL3cache,anduptothree9.6GTpsQPIinterconnectlinks.

    SupportsDDR4memoryatspeedsupto1866MHz,orDDR3memoryatspeedsupto1600MHz

    Supportsupto96DIMMsockets,with24DIMMsperprocessor.

    WitheXFlashmemory-channelstorage,theserverdeliversupto12.8TBofultra-lowlatencyflashmemorybyusingWriteNowtechnology,whichisidealforhigh-performanceapplications.

    IntelligentandadaptivesystemperformancewithIntelTurboBoostTechnology2.0allowsprocessorcorestorunatmaximumspeedsduringpeakworkloadsbytemporarilygoingbeyondprocessorthermaldesignpower(TDP).

    IntelHyper-ThreadingTechnologyboostsperformanceformulti-threadedapplicationsbyenablingsimultaneousmulti-threadingwithineachprocessorcore,uptotwothreadspercore.

    IntelVirtualizationTechnologyintegrateshardware-levelvirtualizationhooksthatallowoperatingsystemvendorstobetterusethehardwareforvirtualizationworkloads.

    IntelAdvancedVectorExtensions(AVX)improvefloating-pointperformanceforcompute-intensivetechnicalandscientificapplications.

    Supportsa12GbpsSASRAIDportfolio.

  • 8/9/2019 Tips 1250

    3/59

    LenovoSystemx3850X6(6241) 3

    Theusageofsolid-statedrives(SSDs)insteadof,oralongwith,traditionalspinningdrives(HDDs)canimproveI/Operformance.AnSSDcansupportupto100timesmoreI/Ooperationspersecond(IOPS)thanatypicalHDD.

    PCIExpress3.0I/Oadapterslotsthatimprovethetheoreticalmaximumbandwidthbyalmost100%(8GTpsperlinkusing128b/130bencoding)comparedtothepreviousgenerationofPCIExpress2.0(5GTpsperlinkusing8b/10bencoding).

    WithIntelIntegratedI/OTechnology,thePCIExpress3.0controllerisintegratedintotheIntelXeonprocessorE7v3andv2productfamilies.ThisintegrationhelpsreduceI/Olatencyandincreaseoverallsystemperformance.

    Supportforuptotwographicsprocessingunits(GPUs)andco-processorstomaximizecomputingpower.

    Energy-efficientelectroniccomponentshelploweroperationalcosts,includinghighlyefficient900W ACand1400WACpowersupplieswith80PLUSPlatinumcertification.

    Agile system design

    Theserverprovidesmanyscalabilityandflexibilityfeatures:

    Innovativemodule"book"designforeachofthethreesubsystems:ComputeBooks,StorageBook,andI/OBooks.Frontandrearaccessmeansthatyoucaneasilyscalethesystembyaddingcomponentswithoutremovingtheentireserverfromtherack.

    Themodularbookdesignalsoallowsclientstocreatetheconfigurationthatfitstheirapplicationandenvironmentneeds,whichreducesacquisitioncostswhilegivingthemtheflexibilitytogrowandmodifytheirconfigurationlater.

    Thebookdesignalsomeansthatsubsystemupgradesaresimpler,quickertoperform,andhavealowerimpactontherestoftheserver.

    Using64GBLRDIMMs,theserversupportsupto6TBofmemory.

    Upto32eXFlashDIMMsaresupportedforatotalof12.8TBoflow-latencyandhigh-performancestorage.

    Upto16x1.8-incheXFlashSSDbays,oruptoeight2.5-inchbays,provideaflexibleandscalableall-in-oneplatformtomeetyourincreasingdemands.

    Offersupto11PCIeslotsplusadedicatedMezzanineLOM(ML2)adapterslot.MostslotsarePCIe3.0tomaximizeI/Oscalability.

    PCIeslotsareimplementedinI/OBookstomaximizemodularity.ChoosefromHalf-lengthI/OBooksorFull-lengthI/OBooks,dependingontheadaptersthatyouneedtodeploy.

    Mostcomponentsarecommonbetweenthefour-socketx3850X6andeight-socketx3950X6,makingforasimpleupgradepathwithminimalpartsonthefloor.

    Resi l ient platform

    Theserverprovidesmanyfeaturestosimplifyserviceabilityandincreasesystemuptime:

    UpwardIntegrationModulesforstandardhypervisorsenablethecreationandmanagementofpoliciestomaintainhighavailabilityofvirtualmachinesandconcurrentupdatingofthesystemfirmware,withnoimpactonapplicationperformanceoravailability.

     AdvancedProcessorRecoveryallowsthesystemtoautomaticallyswitchaccessandcontrolofnetworking,management,andstorageintheeventofaprocessor1failure,providinghigheravailabilityandproductivity.

  • 8/9/2019 Tips 1250

    4/59

    LenovoSystemx3850X6(6241) 4

     AdvancedPageRetireproactivelyprotectsapplicationsfromcorruptedpagesinmemory,whichiscrucialforscalingmemorytoterabytes.

    Redundantbitsteering,memorymirroring,andmemoryranksparingforredundancyintheeventofanon-correctablememoryfailure.

    IntelExecuteDisableBitfunctionalitycanhelppreventcertainclassesofmaliciousbufferoverflowattackswhencombinedwithasupportedoperatingsystem.

    IntelTrustedExecutionTechnologyprovidesenhancedsecuritythroughhardware-basedresistancetomalicioussoftwareattacks,allowinganapplicationtoruninitsownisolatedspace,whichisprotectedfromallothersoftwarerunningonasystem.

    RedundantIntelPlatformControllerHub(PCH)connectionstotheprocessorsallowtheplatformtomaintainaccesstonetworking,storage,andservermanagementduringaprocessorfailure.

    Hot-swapdrivessupportRAIDredundancyfordataprotectionandgreatersystemuptime.

    Hot-swapI/OBooksenablingyoutoinstallorreplaceadapterswhiletheserverisstillrunning.

    Tool-lesslid-lessdesignprovidesfrontandrearaccessforeasyupgradesandserviceability.Thereisnoneedtopulltheserveroutoftheracktoaccessinternalcomponents.

    Hot-swappowersuppliesandhot-swapdual-motorredundantfansprovideavailabilityfor

    mission-criticalapplications.

     AnewLCDdiagnosticspanelthatiscombinedwithindividuallightpathdiagnosticLEDsquicklyleadthetechniciantofailed(orfailing)components,whichsimplifiesservicing,speedsupproblemresolution,andhelpsimprovesystemavailability.

    PredictiveFailureAnalysis(PFA)detectswhensystemcomponents(processors,memory,HDDs,SSDs,fans,andpowersupplies)operateoutsideofstandardthresholdsandgeneratesproactivealertsinadvanceofapossiblefailure,thereforeincreasinguptime.

    Built-inIntegratedManagementModuleVersionII(IMM2)continuouslymonitorssystemparameters,triggersalerts,andperformsrecoveringactionsincaseoffailurestominimizedowntime.

    IncludesaspecialMezzanineLOM(ML2)adapterslotwithsupportforadapterswitheithertwo10Gbportsor4Gbports.SupportsdirectconnectivitytotheIMM2serviceprocessorforout-of-band

    systemsmanagement.

    Integratedindustry-standardUnifiedExtensibleFirmwareInterface(UEFI)enablesimprovedsetup,configuration,andupdates,andsimplifieserrorhandling.

    TwointegratedTrustedPlatformModules(TPMs)1.2supportenablesadvancedcryptographicfunctionality,suchasdigitalsignaturesandremoteattestation.

    Industry-standardAdvancedEncryptionStandard(AES)NIsupportforfasterandstrongerencryption.

    IBMSystemsDirector®providesproactivesystemsmanagement.Itofferscomprehensivesystemsmanagementtoolsthathelpincreaseuptime,reducecosts,andimproveproductivitythroughadvancedservermanagementcapabilities.

    Solid-statedrives(SSDs)offerbetterreliabilitythantraditionalmechanicalHDDsforgreateruptime.

    Built-indiagnostictests,usingDynamicSystemsAnalysis(DSA)Preboot,speeduptroubleshooting

    taskstoreduceservicetime.

    Three-yearcustomer-replaceableunitandonsitelimitedwarranty,9x5nextbusinessday.Optionalserviceupgradesareavailable.

  • 8/9/2019 Tips 1250

    5/59

    LenovoSystemx3850X6(6241) 5

    Locat ions of key components and connectors

    Thefollowingfigureshowsthefrontofthex3850X6server.

    Figure2.FrontviewoftheLenovoSystemx3850X6

    Thefollowingfigureshowstherearofthex3850X6server.

    Figure3.RearviewoftheLenovoSystemx3850X6

  • 8/9/2019 Tips 1250

    6/59

    LenovoSystemx3850X6(6241) 6

    Standard specif ications

    Thefollowingtableliststhestandardspecifications.

    Table1.Standardspecifications(Part1)

    Com ponents Specif ication

    Machinetype 6241

    Firmware Lenovo-signedfirmware

    Formfactor 4Urack.

    Processor ModelswithE7v3processors :One,twoorfourIntelXeonE7-4800v3orE7-8800v3processors,eachinaComputeBook.Processoroptionsbetween4cores(3.2GHz)and18cores(upto2.5GHz).ThreeQPIlinksupto9.6GT/seach.ComputeBookshaveeitherDDR3memoryupto1600MHzorTruDDR4memoryupto1866MHz,butcannotbemixed.Upto45MBL3cache.IntelC602Jchipset.ModelswithE7v2processors :UptofourIntelXeonE7-4800v2orE7-8800v2processors,eachinaComputeBook.Eachprocessorhasbetweensixcores(upto3.4GHz)and15cores(upto2.8GHz).ThreeQPIlinksupto8.0GTpseach.ComputeBookshaveDDR3memoryup

    to1600MHzmemoryspeed.Upto37.5MBL3cache.IntelC602Jchipset.

    Memory Upto96DIMMsockets(24DIMMsperprocessor,installedintheComputeBook).RDIMMsandLRDIMMs(LoadReducedDIMMs)aresupported,butmemorytypescannotbeintermixed.MemoryiseitherTruDDR4memory(upto1866MHz)orDDR3memory(upto1600MHz),dependingontheComputeBookselected.DDR3memoryandTruDDR4memorycannotbemixedinthesameComputeBook.ComputeBookswithDDR3memoryandComputeBookswithTruDDR4memorycannotbemixedinthesamesystem.

    Memorymaximums

    ModelswithTruDDR4ComputeBooks:WithRDIMMs:Upto3TBwith96x32GBRDIMMsandfourprocessorsWithLRDIMMs:Upto6TBwith96x64GBLRDIMMsandfourprocessorsModelswithDDR3ComputeBooks:WithRDIMMs:Upto1.5TBwith96x16GBRDIMMsandfourprocessorsWithLRDIMMs:Upto6TBwith96x64GBLRDIMMsandfourprocessors

    Memoryprotection

    ECC,Chipkill,RBS,memorymirroring,andmemoryranksparing.

    Memorychannelstorage

    SupportedonlyinComputeBookswithDDR3memory;notsupportedwithTruDDR4memory.eXFlashDIMMsareinstalledinmemoryDIMMslots,butareseenbytheOSasstoragedevices.MemorychannelswitheXFlashDIMMsmustalsohaveatleastoneRDIMM.CannotbemixedwithLRDIMMs.Amaximumof32eXFlashDIMMscanbeinstalled.Maximum12.8TBwith32x400GBeXFlashDIMMs.

    Diskdrivebays Upto161.8"eXFlashSSDbays,orupto82.5"hot-swapSAS/SATAbays.

    Maximuminternalstorage

    Upto30.7TBwith3.84TB2.5-inchSASSSDsorupto14.4TBwith1.8TB2.5-inchSASHDDs.

    RAIDsupport 12GbSAS/SATARAID0,1,or10withServeRAIDM5210;optionalupgradestoRAID5and50areavailable(zero-cache;1GBnon-backedcache;1GBor2GBflash-backedcache).UpgradestoRAID6or60availableforM5210with1GBor2GBupgrades.

    Opticalandtapebays

    Nointernalbays;useanexternalUSBdrive.Seehttp://support.lenovo.com/en/documents/pd011281foroptions.

    Networkinterfaces

    MezzanineLOM(ML2)slotfordual-port10GbEcardswithSFP+orRJ-45connectorsorquad-portGbEcardswithRJ-45connectors.SeeTable2.Dedicated1GbEportforsystemsmanagement.

    http://support.lenovo.com/en/documents/pd011281http://support.lenovo.com/en/documents/pd011281

  • 8/9/2019 Tips 1250

    7/59

    LenovoSystemx3850X6(6241) 7

    Table1.Standardspecifications(Part2)

    Com ponents Specification

    PCIExpansionslots

    Upto11PCIeslotsplusdedicatedMezzanineLOMslot.Theslotsareasfollows:TwoPCIe3.0x8slotsforinternalRAIDcontrollers(StorageBook)

    TwoPCIe3.0x16slots(x16-wired),halflength,fullheight(PrimaryI/OBook)

    OnePCIe3.0x16(x8-wired),halflength,fullheight(PrimaryI/OBook)OneML2slotfornetworkadapter(PCIe3.0x8)(PrimaryI/OBook)

    TwooptionalI/OBooks,eachwiththreeslots,allfullheight(usingtheseI/OBooksrequiresfourprocessors).Optionalbooksarehot-swapcapable.

    OptionalI/OBookscanbeeitherofthefollowingoptions:Half-lengthI/OBook:TwoPCIe3.0x8slots,onePCIe3.0x16slot.

    Full-lengthI/OBook:TwoPCIe3.0x16,onePCIe2.0x4slot;twoauxpowerconnectors:150Wand75W.Supportsonedouble-wideGPUupto300W.

    Ports Front:TwoUSB3.0,oneUSB2.0,andoneDB-15videoports.Rear:FourUSB2.0,oneDB-15video,oneDB-9serial,andone1GbERJ-45systemsmanagement.Internal:USB2.0portforembeddedhypervisor.

    Cooling CalibratedVectoredCooling™.Uptotenredundanthot-swapfanpacksandfivefanzoneswithN+1fanredundancy.Eachfanpackincludestwocounter-rotateddual-motorfans.

    Powersupply Uptofourredundanthot-swap900WACor1400WACpowersupplies(all80PLUSPlatinumcertified).-48V750WDCpowersuppliesareavailablethroughCTO.Powersuppliescannotbemixed.

    Hot-swapparts Drives,powersupplies,fans,andoptionalI/OBooks.

    Video MatroxG200eR2with16MBmemorythatisintegratedintotheIMM2.Maximumresolutionis1600x1200at75Hzwith16Mcolors.

    Securityfeatures

    Power-onpassword,adminpassword,andtwoTrustedPlatformModules(TPMs).

    Systemsmanagement

    UEFI,IntegratedManagementModuleII(IMM2)withremotepresencefeature,PredictiveFailureAnalysis,LightPathDiagnostics,AutomaticServerRestart,LenovoXClarity Administrator,IBMSystemsDirectorandActiveEnergyManager™,andServerGuide.

    Operatingsystems

    MicrosoftWindowsServer2012R2,2012,and2008R2,RHEL6and7,SLES11and12,andVMwarevSphereESXi.See"Supportedoperatingsystems"sectionfordetails.

    Limitedwarranty

    Three-yearcustomer-replaceableunit(CRU)andonsitelimitedwarrantywith9x5nextbusinessday(NBD).

    Serviceandsupport

    OptionalserviceupgradesareavailablethroughServicePac®offerings:4-houror2-hourresponsetime,8-hourfixtime,1-yearor2-yearwarrantyextension,andremotetechnicalsupportforLenovohardwareandsomeLenovo/OEMapplications.

    Dimensions Height:173mm(6.8in.),width:482mm(19.0in.),depth:804mm(31.6in),depthwithcablemanagementbracketsinstalled:836mm(32.9in),depthwithFull-lengthI/OBookinstalled:921mm(36.2in)

    Weight Minimumconfiguration:35.9kg(79.2lb),typical:46.4kg(102.3lb),maximum:54.7kg(120lb)

    Theserverisshippedwiththefollowingitems:

    RailkitCablemanagementbrackets2.8m(9.18ft)C13-C14powercord(oneforeachpowersupply)DocumentationCDandsafety/warranty/installationinformation

  • 8/9/2019 Tips 1250

    8/59

    LenovoSystemx3850X6(6241) 8

    Standard models

    Thefollowingtableliststhestandardmodels.

    Table2.Standardmodels

    M o de l† In te l X e on P ro ce s so r*

     in a Compute Book)

    M em ory eXFlash

    DIMMs

    R AID D rive bays

    Drives

    Ethernet

    I/O

    slots§

    Power

    supplies

    x3850 X6 models wi th E7 v3 processors and TruDDR 4 memory

    6241-D5x

    1xE7-4809v38C2.0GHz20MB115W

    2x8GBDDR4(1866MHz)¤

    Nosupport Optional Optional 4x1GbE 6std12max

    1x900WHS/4

    6241-F2x

    2xE7-4820v310C1.9GHz25MB115W

    4x16GBDDR4(1866MHz)¤

    Nosupport 1xM5210 4x2.5"/8Openbay

    4x1GbE 6std12max

    2x900WHS/4

    6241-F4x

    2xE7-4850v314C2.2GHz35MB115W

    4x16GBDDR4(1866MHz)¤

    Nosupport 1xM5210 4x2.5"/8Openbay

    2x10GbE‡

    6std12max

    2x900WHS/4

    6241-G2x

    2xE7-8860v316C2.2GHz40MB140W

    4x16GBDDR4(1866MHz)¤

    Nosupport 1xM5210 4x2.5"/8Openbay

    4x1GbE 6std12max

    2x900WHS/4

    6241-G4x

    2xE7-8890v318C2.5GHz45MB165W

    4x16GBDDR4(1866MHz)¤

    Nosupport 1xM5210 4x2.5"/8Openbay

    4x1GbE 6std12max

    2x900WHS/4

    x3850 X6 models wi th E7 v3 processors and DDR 3 memory

    6241-D4x

    1xE7-4809v38C2.0GHz20MB115W

    2x8GBDDR31600MHz

    Optional Optional Optional 4x1GbE 6std12max

    1x900WHS/4

    6241-F1x

    2xE7-4820v310C1.9GHz25MB115W

    4x16GBDDR31600MHz

    Optional 1xM5210 4x2.5"/8Openbay

    4x1GbE 6std12max

    2x900WHS/4

    6241-F3x

    2xE7-4850v314C2.2GHz35MB115W

    4x16GBDDR31600MHz

    Optional 1xM5210 4x2.5"/8Openbay

    2x10GbE‡

    6std12max

    2x900WHS/4

    6241-G1x

    2xE7-8860v316C2.2GHz40MB140W

    4x16GBDDR31600MHz

    Optional 1xM5210 4x2.5"/8Openbay

    4x1GbE 6std12max

    2x900WHS/4

    6241-G3x

    2xE7-8890v318C2.5GHz45MB165W

    4x16GBDDR31600MHz

    Optional 1xM5210 4x2.5"/8Openbay

    4x1GbE 6std12max

    2x900WHS/4

    x3850 X6 models wi th E7 v2 processors and DDR 3 memory

    6241-A4x

    1xE7-4809v26C1.9GHz12MB105W

    2x8GBDDR3(1333MHz)¤

    Optional Optional Optional 4x1GbE 6std12max

    1x900WHS/4

    6241-B1x

    2xE7-4820v28C2.0GHz16MB105W

    4x8GBDDR31600MHz

    Optional 1xM5210 4x2.5"/8Openbay

    4x1GbE 6std12max

    2x900WHS/4

    6241-B3x

    2xE7-4850v212C2.3GHz24MB105W

    4x8GBDDR31600MHz

    Optional 1xM5210 4x2.5"/8Openbay

    2x10GbE‡

    6std12max

    2x900WHS/4

    6241-C1x

    2xE7-4860v212C2.6GHz30MB130W

    4x8GBDDR31600MHz

    Optional 1xM5210 4x2.5"/8Openbay

    4x1GbE 6std12max

    2x900WHS/4

    6241-C4x

    2xE7-4890v215C2.8GHz37.5MB155W

    4x8GBDDR31600MHz

    Optional 1xM5210 4x2.5"/8Openbay

    4x1GbE 6std12max

    2x900WHS/4

    †xintheMachineTypeModel(MTM)representsacountry-specificletter(forexample,theEMEAMTMis

    6241-A4G,andtheUSMTMis6241-A4U).AskaLenovorepresentativeforspecifics.*Processordetail:Processorquantityandmodel,cores,corespeed,L3cache,andTDP.¤TheDIMMsinthesemodelsoperateatthespeedindicatedtomatchthememorybusspeedoftheprocessor‡ModelF3x,F4x,B3xincludetheBroadcomNetXtremeIIML2DualPort10GbESFP+adapter(BCM57810Sbased).AllothermodelsincludeIntelI350-T4ML2QuadPortGbEAdapteradapter(I350-AM4based).

    §ModelswithsixslotshavethePrimaryI/OBook(fourslots)andStorageBook(twoslots)standard.

  • 8/9/2019 Tips 1250

    9/59

  • 8/9/2019 Tips 1250

    10/59

  • 8/9/2019 Tips 1250

    11/59

    LenovoSystemx3850X6(6241) 11

    Upgrading Compute Books

    Withthex3850X6,machinetype6241,wesupportupgradingtheserverfromIntelXeonE7v2processorstoIntelXeonE7v3processors,simplybyreplacingtheComputeBooks.Theprocesstoupgradeismadeverysimplebecauseoftheinnovatebookdesignofthex3850X6.

    Notes:eXFlashDIMMsarenotsupportedwithTruDDR4memory;OnlyDDR3memoryissupportedIntelXeonE7v3processorsrequireminimumfirmwarelevels.ConsultthedocumentationthatisincludedwiththeComputeBooks.

    IfyouplantouseyourexistingDDR3memory,theprocesstoupgradeisasfollows:

    Purchaseupto4newComputeBooks1.Checkandifnecessary,upgradeallfirmwaretoatleasttheminimumlevelsneededtosupportE7v32.processorsPowerofftheserverandremovetheexistingE7v2ComputeBooks3.TransferallDDR3memoryDIMMstothenewE7v3ComputeBooks4.ReinstallthenewE7v3ComputeBooks5.

    IfyouplantoupgradetoTruDDR4memory,thenyoushouldalsoordertheappropriatememoryDIMMstomatchyourworkloadrequirements.

    Upgrad ing to an 8-socket system

    Thex3850X6serverhasaflexiblemodulardesignthatallowsyoutoincreasetheserver’scomputepowerandI/OcapabilitiesbyaddingadditionalComputeBooksandI/OBooks.ThemodulardesignalsomeansthatifyourbusinessneedsadditionalprocessingorI/Ocapabilitywithinthesamesystemimage,thenitispossibletomigratetoaneight-socketx3950X6.

    Lenovosupportsupgradinga4-socketX6servertoan8-socketX6server.Thetworecommendedmethodsareasfollows:

    Startwitha4-socketx3950X6(8Uchassis)andaddadditionalprocessorswhenneededStartwitha4-socketx3850X6(4Uchassis)andupgradeitwhenneededusinganRPQprocess

    Option 1: Start with a 4-socket x3950 X6

    Withthisoption,youplanfortheneedforfuture8-socketperformanceinadvanceandpurchaseanx3950X6withonlyfourComputeBooksinstalled.Theinitialorderwouldcontain:

    FourComputeBookswithE7-8800v2seriesprocessorsFourPowerSupplies(preferably1400W)TwoPrimaryIOBookstandardTwoStorageBookStandard

    Oncetheneedarisestoupgradetheservertosixoreightprocessors,simplypurchasemoreComputeBookswiththesameprocessormodel,plusadditionalpowersupplies(asdeterminedbyusingthePowerConfigurator),I/OBooks,adaptersanddrivesasneeded.

    Forinformationaboutthex3950X6,seetheLenovoSystemx3950X6ProductGuide:http://lenovopress.com/tips1251

    http://lenovopress.com/tips1251http://lenovopress.com/tips1251

  • 8/9/2019 Tips 1250

    12/59

    LenovoSystemx3850X6(6241) 12

    Note :ItissupportedtoinstallComputeBooksinax3950X6fromeitheranSystemx3850X6(machinetype3837)oraLenovoSystemx3850X6(machinetype6241)

    Option 2: Upgrade your 4-socket x3850 X6 using an RPQ

    Withthisoption,youdon’thavetoplanfor8-socketcapacityupfront.Youstartwithanx3850X6thenwhenyouarereadytoupgradetoa6-socketor8-socketserver,youpurchaseanupgradeofferingviaanRPQ.

     AspartoftheRPQ,anserviceengineercomesonsitewiththenewmechanicalchassisandperformsthefieldupgradebytransferringallcomponentstothenewchassis.Thismethodalsorequiresthex3850X6computebooksbethesameE7-8800v2processorsasorderedfortheRPQ,however,inthisscenario,theservermaintaintheoriginalserialnumber.

    Note

    :UseofE7-4800v2processors:IntelXeonE7-4800v2processorscannotbeusedinanx3950X6.Ifyourx3850X6hasComputeBookswithE7-4800v2processors,thenthesemustbereplacedwithComputeBookswithE7-8800v2processorsifyouplantoupgradetoanx3950X6.ThememoryintheComputeBookscanbereusedinthex3950X6,however.

    Forthismethod,submitanRPQforassessmentandpricing.Theexistingx3850X6configurationwillbe

    evaluatedandrecommendationswillbemadebasedontheworkloadrequirements.

    Themajorpartsofthe4Uto8Uupgradearethe8Uchassis,theStorageBookandthePrimaryI/OBook. Allthecomponentsinthepackagewillbeinstalledinthetopportionofthechassis.The4Usystem'scomponentswillbetransferredtothebottomsectionofthechassis.

    Eventhoughthisupgraderequiresanew8Uchassisreplacingtheexisting4Uchassis,themajorityofinternalcomponentscanbemovedfromthex3850X6tothex3950X6.

    Thex3850X6componentsthatcanbemigratedtothex3950X6aspartoftheRPQupgradeare:

    ComputeBooks,providedtheyuseIntelXeonE7-8800v2processors AllmemoryDIMMs

    StorageBook AllinternaldrivesPrimaryI/OBook(andassociatedfans)Half-lengthI/OBooksFull-lengthI/OBooks Alladapters Allpowersupplies

    TheRPQupgradeincludestheseparts:

    New8Uchassisand8-socketmidplane AsecondStorageBook AsecondPrimaryI/OBook

    TheRPQupgrademayalsorequirenewparts:

     AdditionalComputeBooks(aminimumoffourComputeBooksrequiredinthex3950X6) Additionalpowersupplies(aminimumoffourarerequiredinthex3950X6) AdditionalI/OBooks,networkadapters,drivesasneeded

  • 8/9/2019 Tips 1250

    13/59

    LenovoSystemx3850X6(6241) 13

    Therearekeyconsiderationsforthisupgrade:

    Processorsupport:IntelXeonE7-4800v2processorscannotbeusedinanx3950X6.Ifyourx3850X6hasComputeBookswithE7-4800v2processors,thenthesemustbereplacedwithComputeBookswithE7-8800v2processorsifyouplantoupgradetoanx3950X6.ThememoryintheComputeBookscanbereusedinthex3950X6,however.

     Allprocessorsmustbeidentical:Allprocessorsusedinthex3950X6mustbetheidentical.Forexample,allE7-8850v2processors.Aminimumoffourprocessorsarerequired.

    Theupgradedoesresultinsomepartsnolongerbeingused(“partsonthefloor”):

    Existing4Uchassisand4-socketmidplane

    ComputeBooksthatarebasedonE7-4800v2processors

    Originalx3850X6servermayneedtobeorderedconfigure-to-order(CTO)orSpecialBid:Tominimize“partsonthefloor”(partsthatcannotbeusedintheupgradedsystem),theoriginalx3850X6shouldbeconfiguredwithComputeBookscontaininE7-8800v2processors.Sincemanystandardmodelsofthex3850X6(seeTable2)containE7-4800v2processors,youmayneedtouseCTO(usingaconfiguratorsuchasx-config)orordertheserverusingSpecialBidtocreateaserverconfigurationwithE7-8800v2processors.

    Serialnumberswap:TheRPQupgradeprocessalsoinvolvestransferringthex3850X6serialnumbertothex3950X6chassis.Thistransfermakestheupgradesimplerfromanassetordepreciationmanagementpointofview.Thistransferalsomeansthattheold4Uchassiswillberetiredasitwillnolongerhaveavalidserialnumber.

    Powersupplies:Ideallyallpowersuppliesarethe1400Wvariant.Regardlessoftheselection,thepowersuppliescoexistencerulesasdecribedinthePowersuppliessectionmustbefollowed.

     Additionalpower:DependingonyourworkloadandconfigurationyoumayneedtoprovisionforadditionalPDUoutlets,cablesandpowercapacityforyourx3950X6server.UsetheLenovoPowerConfiguratortodetermineyourtotalpowerdrawtoassistyouinprovisioningadequatepower.YoucandownloadthePowerConfiguratorfromhttp://ibm.com/systems/bladecenter/resources/powerconfig.html

     Additionalrackspace:Anadditional4Uofrackspaceisrequiredwhenupgradingthex3850X6tothex3950X6,foratotalof8Uofrackspace.

    Downtime:Inordertoupgradethex3850X6servertoax3950X6serveryouwillneedtoallowfordowntime.Theserverwillneedtobecompletelypoweredoffandhavesomeofitscomponentsremovedforre-installationintothenewx3950X6server.

    http://ibm.com/systems/bladecenter/resources/powerconfig.htmlhttp://ibm.com/systems/bladecenter/resources/powerconfig.html

  • 8/9/2019 Tips 1250

    14/59

    LenovoSystemx3850X6(6241) 14

    Processor options

    Thex3850X6supportsuptofourIntelXeonE7processors,eitherE7v3orE7v2.ProcessorsareinstalledinComputeBooks,oneprocessorineachComputeBook.ThefollowingfigureshowsthecomponentsoftheComputeBook:

    Oneprocessor

     Atotalof24DIMMslots,12oneachsideofthebookTwohot-swapdual-motorfansthataremountedonthefrontofthebook

    Thex3850X6supportstwoorfourComputeBooks.ThreeComputeBooksarenotsupported.AconfigurationofoneComputeBookisonlysupportedinstandardmodels6241-A4xand6241-D5x.

    EachComputeBookisinstalledinthefrontoftheserver,asshowninthefollowingfigure.

    Figure4.ComputeBook

    Thefollowingtableshowstheprocessoroptions,groupedasfollows:

    E7-4800v3processorsinComputeBookswithDDR3supportE7-8800v3processorsinComputeBookswithDDR3supportE7-4800v3processorsinComputeBookswithTruDDR4supportE7-8800v3processorsinComputeBookswithTruDDR4supportE7-4800v2processorsinComputeBookswithDDR3supportE7-8800v2processorsinComputeBookswithDDR3support

    EachoptionincludestheprocessorinstalledinaComputeBook.ComputeBookswithoneoftheE7-4800familyofprocessorsaresupportedonlyinafour-socketx3850X6serverandcannotbeusedinanx3950X6server.AllComputeBooksinstalledinaservermustbeidentical.

    Thetablealsoshowsthemaximummemorybusspeedeachprocessorsupportspluswhichservermodelshaveeachprocessorstandard.Ifthereisnocorrespondingwhere-used modelforaparticularprocessor,thisprocessorisonlyavailablethroughCTO.

  • 8/9/2019 Tips 1250

    15/59

    LenovoSystemx3850X6(6241) 15

    Table4.Processoroptions(Part1)

    Part number

    Feature codes‡

    Descript ion

     processor installed in

    a Compute Book)

    L3

    cache

    Memory

    support

    Memory bus

    speed RAS /

    Performance)†

    Supported

    quantities

    x3850 X6*

    x3850 X6

    models

    where used

    Inte l Xeon E7-4800 v3 processors wi th support for DDR3 m emory not supported in the x3950 X6)

    00ML902 AS7T/AS8H X6DDR3ComputeBookIntelXeonProcessorE7-4809v38C2.0GHz115W 20MB DDR3 1333/1333MHz 2,4 D4x

    00ML906 AS7U/AS8J

    X6DDR3ComputeBookIntelXeonProcessorE7-4820v310C1.9GHz115W

    25MB DDR3 1333/1333MHz 2,4 F1x

    00ML910 AS7V/AS8K

    X6DDR3ComputeBookIntelXeonProcessorE7-4830v312C2.1GHz115W

    30MB DDR3 1600/1333MHz 2,4 -

    00ML914 AS7W/AS8L

    X6DDR3ComputeBookIntelXeonProcessorE7-4850v314C2.2GHz115W

    35MB DDR3 1600/1333MHz 2,4 F3x

    In te l Xeon E7-8800 v3 processors wi th support for DDR3 m emory a lso supported in the x3950 X6)

    00ML922

     AS7X/AS8M

    X6DDR3ComputeBookIntelXeon

    ProcessorE7-8860v316C2.2GHz140W

    40MB DDR3 1600/1600MHz 2,4 G1x

    00FP692 AS7R/AS8F

    X6DDR3ComputeBookIntelXeonProcessorE7-8867v316C2.5GHz165W

    45MB DDR3 1600/1600MHz 2,4 -

    00ML926 AS7Y/AS8N

    X6DDR3ComputeBookIntelXeonProcessorE7-8870v318C2.1GHz140W

    45MB DDR3 1600/1600MHz 2,4 -

    00ML930 AS7Z/AS8P

    X6DDR3ComputeBookIntelXeonProcessorE7-8880v318C2.3GHz150W

    45MB DDR3 1600/1600MHz 2,4 HANAmodels

    00ML938 AS81/AS8R

    X6DDR3ComputeBookIntelXeonProcessorE7-8880Lv318C2.0GHz115

    45MB DDR3 1600/1600MHz 2,4 -

    00ML934 AS80/AS8Q

    X6DDR3ComputeBookIntelXeonProcessorE7-8890v318C2.5GHz165W

    45MB DDR3 1600/1600MHz 2,4 G3x

    00ML942 AS82/AS8S

    X6DDR3ComputeBookIntelXeonProcessorE7-8891v310C2.8GHz165W

    45MB DDR3 1600/1600MHz 2,4 -

    00ML946 AS83/AS8T

    X6DDR3ComputeBookIntelXeonProcessorE7-8893v34C3.2GHz140W

    45MB DDR3 1600/1600MHz 2,4 -

    In te l Xeon E7-4800 v3 processors wi th support for TruDDR4 m emory not supported in the x3950 X6)

    00ML950 AS84/AS8U

    X6DDR4ComputeBookIntelXeonProcessorE7-4809v38C2.0GHz115W

    20MB TruDDR4 1866/1333MHz 2,4 D5x

    00ML954 AS85/AS8V X6DDR4ComputeBookIntelXeonProcessorE7-4820v310C1.9GHz115W

    25MB TruDDR4 1866/1333MHz 2,4 F2x

    00ML958 AS86/AS8W

    X6DDR4ComputeBookIntelXeonProcessorE7-4830v312C2.1GHz115W

    30MB TruDDR4 1866/1333MHz 2,4 -

    00ML962 AS87/AS8X

    X6DDR4ComputeBookIntelXeonProcessorE7-4850v314C2.2GHz115W

    35MB TruDDR4 1866/1333MHz 2,4 F4x

  • 8/9/2019 Tips 1250

    16/59

    LenovoSystemx3850X6(6241) 16

    Table4.Processoroptions(Part2)

    Part number

    Feature codes‡

    Descript ion

     processor installed in

    a Compute Book)

    L3

    cache

    Memory

    support

    Memory bus

    speed RAS /

    Performance)†

    Supported

    quantities

    x3850 X6*

    x3850 X6

    models

    where used

    Inte l Xeon E7-8800 v3 processors wi th support for TruDDR4 m emory a lso supported in the x3950 X6)

    00ML970 AS88/AS8Y X6DDR4ComputeBookIntelXeonProcessorE7-8860v316C2.2GHz140W

    40MB TruDDR4 1866/1600MHz 2,4 G2x

    00FP696 AS7S/AS8G

    X6DDR4ComputeBookIntelXeonProcessorE7-8867v316C2.5GHz165W

    45MB TruDDR4 1866/1600MHz 2,4 -

    00ML974 AS89/AS8Z

    X6DDR4ComputeBookIntelXeonProcessorE7-8870v318C2.1GHz140W

    45MB TruDDR4 1866/1600MHz 2,4 -

    00ML978 AS8A/AS90

    X6DDR4ComputeBookIntelXeonProcessorE7-8880v318C2.3GHz150W

    45MB TruDDR4 1866/1866MHz 2,4 HANAmodels

    00ML986 AS8C/AS92

    X6DDR4ComputeBookIntelXeonProcessorE7-8880Lv318C2.0GHz115

    45MB TruDDR4 1866/1600MHz 2,4 -

    00ML982 AS8B/AS91

    X6DDR4ComputeBookIntelXeonProcessorE7-8890v318C2.5GHz165W

    45MB TruDDR4 1866/1600MHz 2,4 G4x

    00ML990 AS8D/AS93

    X6DDR4ComputeBookIntelXeonProcessorE7-8891v310C2.8GHz165W

    45MB TruDDR4 1866/1600MHz 2,4 -

    00ML994 AS8E/AS94

    X6DDR4ComputeBookIntelXeonProcessorE7-8893v34C3.2GHz140W

    45MB TruDDR4 1866/1600MHz 2,4 -

    In te l Xeon E7-4800 v2 processors wi th support for DDR3 m emory not supported in the x3950 X6)

    44X3961 A4AM/A4B3

    X6ComputeBookIntelXeonProcessorE7-4809v26C1.9GHz105W

    12MB DDR3 1333/1066MHz 2,4 A4x

    44X3966 A4AN/A4B4

    X6ComputeBookIntelXeonProcessorE7-4820v28C2.0GHz105W

    16MB DDR3 1600/1066MHz 2,4 B1x

    44X3971 A4AP/A4B5

    X6ComputeBookIntelXeonProcessorE7-4830v210C2.2GHz105W

    20MB DDR3 1600/1066MHz 2,4 -

    44X3976 A4AQ/A4B6

    X6ComputeBookIntelXeonProcessorE7-4850v212C2.3GHz105W

    24MB DDR3 1600/1066MHz 2,4 B3x

    44X3981 A4AR/A4B7

    X6ComputeBookIntelXeonProcessorE7-4860v212C2.6GHz130W

    30MB DDR3 1600/1333MHz 2,4 C1x

    44X3986 A4AS/A4B8

    X6ComputeBookIntelXeonProcessorE7-4870v215C2.3GHz130W

    30MB DDR3 1600/1333MHz 2,4 -

    44X3991 A4AT/A4B9

    X6ComputeBookIntelXeonProcessorE7-4880v215C2.5GHz130W

    37.5MB DDR3 1600/1333MHz 2,4 -

    44X3996 A4AU/A4BA

    X6ComputeBookIntelXeonProcessorE7-4890v215C2.8GHz155W

    37.5MB DDR3 1600/1333MHz 2,4 C4x

  • 8/9/2019 Tips 1250

    17/59

    LenovoSystemx3850X6(6241) 17

    Table4.Processoroptions(Part3)

    Part number

    Feature codes‡

    Descript ion

     processor installed in

    a Compute Book)

    L3

    cache

    Memory

    support

    Memory bus

    speed RAS /

    Performance)†

    Supported

    quantities

    x3850 X6*

    x3850 X6

    models

    where used

    Inte l Xeon E7-8800 v2 processors wi th support for DDR3 m emory a lso supported in the x3950 X6)

    44X4001 A4AV/A4BB X6ComputeBookIntelXeonProcessorE7-8850v212C2.3GHz105W 24MB DDR3 1600/1066MHz 2,4 -

    44X4031 A4B1/A4BH

    X6ComputeBookIntelXeonProcessorE7-8857v212C3.0GHz130W

    30MB DDR3 1600/1333MHz 2,4 -

    44X4011 A4AX/A4BD

    X6ComputeBookIntelXeonProcessorE7-8870v215C2.3GHz130W

    30MB DDR3 1600/1333MHz 2,4 -

    44X4016 A4AY/A4BE

    X6ComputeBookIntelXeonProcessorE7-8880v215C2.5GHz130W

    37.5MB DDR3 1600/1333MHz 2,4 HANAmodels

    44X4021 A4B2/A4BF

    X6ComputeBookIntelXeonProcessorE7-8880Lv215C2.2GHz105W

    37.5MB DDR3 1600/1333MHz 2,4 -

    44X4026 A4AZ/A4BG

    X6ComputeBookIntelXeonProcessorE7-8890v215C2.8GHz155W

    37.5MB DDR3 1600/1333MHz 2,4 -

    44X4006 A4B0/A4BC

    X6ComputeBookIntelXeonProcessorE7-8891v210C3.2GHz155W

    37.5MB DDR3 1600/1333MHz 2,4 -

    44X4036 A4AW/A4BJ

    X6ComputeBookIntelXeonProcessorE7-8893v26C3.4GHz155W

    37.5MB DDR3 1600/1333MHz 2,4 -

    ‡ThefirstfeaturecodeisforthefirstComputeBook.ThesecondfeaturecodeisforalladditionalComputeBooks†Theprocessorssupporttwomemorymodes,RASmode(alsoknownaslockstepmode)andPerformancemode(alsoknownasindependentmode).InPerformancemode,theSMI2linkoperatesattwicethememorybusspeedshown.*Aconfigurationofoneprocessorisonlysupportedinmodels6241-A4xand6241-D5x.NootherservermodelorCTOconfigurationsupportsoneprocessor.

    Mem ory opt ions

    Thex3850X6(6241)supportseitherDDR3orTruDDR4memory,dependingontheComputeBooksusedintheserver.

    LenovoTruDDR4MemoryusesthehighestqualitycomponentsthataresourcedfromTier1DRAMsuppliersandonlymemorythatmeetsthestrictrequirementsofLenovoisselected.Itiscompatibilitytestedandtunedtomaximizeperformanceandreliability.TruDDR4MemoryhasauniquesignaturethatisprogrammedintotheDIMMthatenablesSystemx®serverstoverifywhetherthememorythatisinstalledisqualifiedorsupportedbyLenovo.BecauseTruDDR4Memoryisauthenticated,certainextendedmemoryperformancefeaturescanbeenabledtoextendperformanceoverindustrystandards.

    LenovoDDR3memoryiscompatibilitytestedandtunedforoptimalSystemxperformanceandthroughput.Lenovomemoryspecificationsareintegratedintothelightpathdiagnosticsforimmediate

    systemperformancefeedbackandoptimumsystemuptime.

    Fromaserviceandsupportstandpoint,LenovoTruDDR4andDDR3memoryautomaticallyassumesthesystemwarranty,andLenovoprovidesserviceandsupportworldwide.

  • 8/9/2019 Tips 1250

    18/59

    LenovoSystemx3850X6(6241) 18

    Thex3850X6supportsTruDDR4memoryoperatingatspeedsupto1866MHzandDDR3memoryatspeedsupto1600MHz.Thex3850X6supportsupto96DIMMswhenallprocessorsareinstalled,24DIMMsperprocessor.EachprocessorhasfourmemorychannelsthatareimplementedusingScalableMemoryInterfacegeneration2(SMI2)chips,andtheserverimplementsthreeDIMMsperchannel.TheprocessorandthecorrespondingmemoryDIMMslotsareontheComputeBook.

    Thefollowingtableliststhememoryoptionsthatareavailableforx3850X6.

    Table5.Memoryoptions

    Part num ber Feature code Description M axim um

    suppor ted

    x3850 X6

    Models

    where used

    TruDDR4RDIMMs

    46W0788 A5B5 8GBTruDDR4Memory(1Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM

    96(24perCPU) D5x

    46W0796 A5B7 16GBTruDDR4Memory(2Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM

    96(24perCPU) F2x,F4x,G2x,G4x

    95Y4808 A5UJ 32GBTruDDR4Memory(2Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM

    96(24perCPU) -

    TruDDR4LRDIMMs

    95Y4812 A5UK 64GBTruDDR4Memory(4Rx4,1.2V)PC4-17000CL152133MHzLPLRDIMM

    96(24perCPU) -

    DDR3RDIMMs

    00D5024 A3QE 4GB(1x4GB,1Rx4,1.35V)PC3L-12800CL11ECCDDR31600MHzLPRDIMM

    96(24perCPU) -

    00D5036 A3QH 8GB(1x8GB,1Rx4,1.35V)PC3L-12800CL11ECCDDR31600MHzLPRDIMM

    96(24perCPU) A4x,B1x,B3x,C1x,C4x,D4x

    46W0672 A3QM 16GB(1x16GB,2Rx4,1.35V)PC3L-12800CL11ECCDDR31600MHzLPRDIMM

    96(24perCPU) F1x,F3x,G1x,G3x

    DDR3LRDIMMs

    46W0676 A3SR 32GB(1x32GB,4Rx4,1.35V)PC3L-12800CL11ECCDDR31600MHzLPLRDIMM

    96(24perCPU) -

    46W0741 A451 64GB(1x64GB,8Rx4,1.35V)PC3-10600DDR31333MHzLPLRDIMM

    96(24perCPU) -

    Thefollowingrulesapplywhenselectingthememoryconfiguration:

    TheserversupportsRDIMMsandLRDIMMs.

    Mixingdifferenttypesofmemory(RDIMMsandLRDIMMs)isnotsupported.

    Mixingdifferentgenerationsofmemory(DDR3andTruDDR4)isnotsupported

    ThemaximumnumberofranksperonememorychannelissixwithRDIMMsor24withLRDIMMs.

    InRAS(lockstep)mode,DIMMsmustbeinstalledinapair.

  • 8/9/2019 Tips 1250

    19/59

    LenovoSystemx3850X6(6241) 19

    ThemaximumquantityofDIMMsthatcanbeinstalledintheserverdependsonthenumberofprocessors,DIMMtype,rank,andoperatingvoltage,asshowninthe"Maximumqtysupported"rowinthefollowingtable.

     AllDIMMsintheserveroperateatthesamespeed,whichisdeterminedasthelowestvalueofoneofthefollowingoptions:

    Memoryspeedthatissupportedbythespecificprocessor.o

    Lowestofmaximumoperatingspeedsforselectedmemoryconfigurationthatdependsonratedospeed,operatingvoltage,andquantityofDIMMsperchannel,asshownunder"Maximumoperatingspeed"sectioninthefollowingtable.

    ConfigurationswithDDR3memoryalsosupportseXFlashDIMMs,whicharealsoinstalledintheDIMMslots.The"eXFlashmemory-channelstorage"sectiondescribestheseeXFlashDIMMsandtheconfigurationrules.

    ThefollowingtablesshowthecharacteristicsofthesupportedDIMMs.Tablecellsthatarehighlightedwithagraybackgroundindicatethattheserversupportshighermemoryfrequenciesorlargermemorycapacity(orboth)thantheIntelprocessorspecificationdefines.

    Memory speed :Inperformancemode,memorychannelsoperateindependently,andtheSMI2link

    operatesattwicetheDDR3speed.InRASmode,twochannelsoperatesynchronously,andtheSMI2linkoperatesattheDDR3speed.

    Table6.Maximummemoryspeeds-DDR3memory

    DIMM

    specification

    D D R 3 R D IM M s D D R 3 LR D IMM s

    Rank Singlerank Dualrank Quadrank 8-rank

    Partnumbers 00D5024(4GB)00D5036(8GB)

    46W0672(16GB) 46W0676(32GB) 46W0741(64GB)

    Ratedspeed 1600MHz 1600MHz 1600MHz 1333MHz

    Ratedvoltage 1.35V 1.35V 1.35V 1.35V

    Operatingvoltage 1.35V 1.5V 1.35V 1.5V 1.35V 1.5V 1.35V 1.5V

    Maxqtysupported* 96 96 96 96 96 96 96 96

    MaxDIMMcapacity 8GB 8GB 16GB 16GB 32GB 32GB 64GB 64GB

    Maxmemorycapacity 0.75TB 0.75TB 1.5TB 1.5TB 3TB 3TB 6TB 6TB

    Maxim um operat ing speed - Per formanc e mode 2:1 mode - SMI2 l ink operates at twice the DDR3 speed

    shown)

    1DIMMperchannel 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz

    2DIMMsperchannel 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz

    3DIMMsperchannel 1066MHz 1333MHz 1066MHz 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz

    Maxim um operat ing speed - RAS mode 1:1 mode - SMI2 l ink operates at the DDR3 speed shown)

    1DIMMperchannel 1333MHz 1600MHz 1333MHz 1600MHz 1333MHz 1600MHz 1333MHz 1333MHz

    2DIMMsperchannel 1333MHz 1600MHz 1333MHz 1600MHz 1333MHz 1600MHz 1333MHz 1333MHz

    3DIMMsperchannel 1066MHz 1333MHz 1066MHz 1333MHz 1333MHz 1333MHz 1333MHz 1333MHz

    *Maximumquantitysupportedisshownforallprocessorsthatareinstalled

  • 8/9/2019 Tips 1250

    20/59

    LenovoSystemx3850X6(6241) 20

    Table7.Maximummemoryspeeds-TruDDR4memory

    Specificat ion TruDDR4 RDIM M s TruDDR4 LRDIM M s

    Rank Singlerank Dualrank Quadrank

    Partnumbers 46W0788(8GB) 46W0796(16GB)95Y4808(32GB)

    95Y4812(64GB)

    Ratedspeed 2133MHz 2133MHz 2133MHz

    Ratedvoltage 1.2V 1.2V 1.2V

    Operatingvoltage 1.2V 1.2V 1.2V

    Maximumquantity* 96 96 96

    LargestDIMM 8GB 16GB 64GB

    Maxmemorycapacity 0.75TB 1.5TB 6TB

    Maxim um operat ing speed - Per formance m ode 2:1 mode - SMI2 l ink operates at twice the speed shown)

    1DIMMperchannel 1600MHz 1600MHz 1600MHz

    2DIMMsperchannel 1600MHz 1600MHz 1600MHz

    3DIMMsperchannel 1600MHz 1600MHz† 1600MHz

    Maxim um operat ing speed - RAS mode 1:1 mode - SMI2 l ink operates at the speed shown)

    1DIMMperchannel 1866MHz 1866MHz 1866MHz

    2DIMMsperchannel 1866MHz 1866MHz 1866MHz

    3DIMMsperchannel 1600MHz 1600MHz† 1866MHz†

    *Maximumquantitysupportedisshownforallprocessorsthatareinstalled†ThisspeedisachievedonlywhenLenovoTruDDR4memoryisused

    Thefollowingmemoryprotectiontechnologiesaresupported:

    ECCChipkill(forx4-basedmemoryDIMMs)Redundantbitsteering(DoubleDeviceDataCorrection)MemorymirroringMemoryranksparing

    ChipkillandRedundantBitSteeringaresupportedinRASmode.ChipkillissupportedinPerformancemode.

    Ifmemorymirroringisused,DIMMsmustbeinstalledinpairsforPerformancemode(minimumofonepairpereachprocessor)andquadsforRASmode.DIMMsinthepair/quadmustbeidenticalintypeand

    size.

    Ifmemoryranksparingisused,thenaminimumoftwosingle-rankordual-rankDIMMsmustbeinstalledperpopulatedchannel(theDIMMsdonotneedbeingidentical).Inranksparingmode,onerankofaDIMMineachpopulatedchannelisreservedassparememory.ThesizeofarankvariesdependingontheDIMMsthatareinstalled.

  • 8/9/2019 Tips 1250

    21/59

    LenovoSystemx3850X6(6241) 21

    eXFlash m emory-channel s torage

    eXFlashmemory-channelstoragearestorageofferingsinthephysicalformofmemoryDIMMs.TheseeXFlashDIMMsareinstalledinmemoryDIMMsocketsbutappeartotheoperatingsystemandapplicationsasblockstoragedevices.Thisnewandinnovativetechnologybringsstorageelectricallyclosertotheprocessorsubsystem,thereforeimprovingperformanceconsiderably.

    Note:eXFlashmemory-channelstorageisonlysupportedwithDDR3memory.TruDDR4memoryisnotsupported.

    ThefollowingtableshowsthesupportedeXFlashDIMMs.

    Table8.Internalstorageexpansionoptions

    Partnumber

    Feature

    code

    Nam e and descrip tion M axim um

    suppor ted

    00FE000 A4GX eXFlash200GBDDR3StorageDIMM 32

    00FE005 A4GY eXFlash400GBDDR3StorageDIMM 32

    ThefollowingfigureshowsoneeXFlashDIMMinstalledwithRDIMMsintheComputeBook.

    Figure5.eXFlashDIMMinstalledintheComputeBook

    ThefollowingrulesapplywhenbuildingaserverconfigurationwitheXFlashDIMMs:

    The200GBand400GBeXFlashDIMMscannotbemixed.

    Performancememorymodemustbeselected.RAS(lockstep)memorymodeisnotsupported.

    eXFlashDIMMscanonlybeinstalledinComputeBookswithDDR3memory

  • 8/9/2019 Tips 1250

    22/59

    LenovoSystemx3850X6(6241) 22

    OnlyRDIMMsaresupportedbyeXFlashDIMMs;LRDIMMsarenotsupported

    ThemaximumquantitiesofeXFlashDIMMsareasfollows:

    Oneprocessor:8eXFlashDIMMsoTwoprocessors:16eXFlashDIMMsoFourprocessors:32eXFlashDIMMso

    Formoreinformation,visittheeXFlashDIMMsupportpage:http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-FLASHDM

    Internal storage

    Thex3850X6serversupports1.8-inchsolid-statedrivesand2.5-inchSSDsandHDDs.DrivesareinstalledintheStorageBook.Thex3850X6hasoneStorageBook.TheStorageBooksupportsthefollowingconfigurations:

    4x2.5-inchhot-swapdrivebays8x2.5-inchhot-swapdrivebays4x2.5-inchhot-swapdrivebays+8x1.8-inchhot-swapSSDbays8x1.8-inchhot-swapSSDbays

    16x1.8-inchhot-swapSSDbays

    Thefollowingfigureshowstheseconfigurations.

    Figure6.Internaldriveconfigurations

    Backplanes

     Allstandardmodelsshipwithfour2.5-inchSAS/SATAhot-swapharddiskdrivebays,exceptmodel6241-A4x.Thefollowingtableshowstheinternalstorageexpansionoptionsthatareavailable.

    Table9.Internalstorageexpansionoptions

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    x3850 X6

    44X4104 A4A6 4x2.5"HS12GbSASHDDBackplane 2

    44X4106 A4A7 8x1.8"HS12GbSASHDDBackplane 2

    http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-FLASHDMhttp://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-FLASHDM

  • 8/9/2019 Tips 1250

    23/59

    LenovoSystemx3850X6(6241) 23

    ThebackplanesareconnectedtooneortwoRAIDcontrollersorHBAsdependingonthenumberandtypeofbackplanethatisinstalled.TheadaptersareinstalledinPCIeslotsintheStorageBook,asshowninthefollowingfigure.

    Figure7.StorageBook

    ThefollowingtableshowsthebackplanesthatarerequiredperStorageBookandthenumberofcontrollersthatarerequired.Notethatthetableshowstheexactnumberofcontrollerssupportedforeachdrive/backplaneconfiguration,nomore,nofewer.

    Table10.DrivecombinationsperStorageBook

    Drive com bination Backplanes required Num ber of

    controllers

    suppor ted

    4x2.5-inchhot-swapdrivebays 1x4x2.5"HS12GbSASHDDBackplane,44X4104 1

    8x2.5-inchhot-swapdrivebays 2x4x2.5"HS12GbSASHDDBackplane,44X4104 1

    4x2.5-inchhot-swapdrivebays+8x1.8-inchhot-swapSSDbays

    1x4x2.5"HS12GbSASHDDBackplane,44X41041x8x1.8"HS12GbSASHDDBackplane,44X4106

    2

    8x1.8-inchhot-swapSSDbays 1x8x1.8"HS12GbSASHDDBackplane,44X4106 1

    16x1.8-inchhot-swapSSDbays 2x8x1.8"HS12GbSASHDDBackplane,44X4106 2

  • 8/9/2019 Tips 1250

    24/59

  • 8/9/2019 Tips 1250

    25/59

    LenovoSystemx3850X6(6241) 25

    Internal dr ive options

    Thefollowingtablelistsharddiskdriveoptionsforinternalstorage.

    Table12.Diskdriveoptionsforinternaldiskstorage(Part1)

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    x3850 X6

    1.8"6GbSATAHSEnterpriseSSDs

    41Y8366 A4FS S3700200GBSATA1.8"MLCEnterpriseSSD 16

    41Y8371 A4FT S3700400GBSATA1.8"MLCEnterpriseSSD 16

    1.8"6GbSATAHSEnterpriseValueSSDs

    00AJ455 A58U S3500800GBSATA1.8"MLCEnterpriseValueSSD 16

    00AJ335 A56V 120GBSATA1.8"MLCEnterpriseValueSSD 16

    00AJ340 A56W 240GBSATA1.8"MLCEnterpriseValueSSD 16

    00AJ345 A56X 480GBSATA1.8"MLCEnterpriseValueSSD 16

    00AJ350 A56Y 800GBSATA1.8"MLCEnterpriseValueSSD 16

    2.5"6GbSASHSEnterpriseCapacitySSDs

    00NA671 ASW6 3.84TB6GbSASEnterpriseCapacityG3HSMLCSSD 8

    2.5"6GbSASHSEnterpriseSSDs

    00AJ207 A4UA 200GBSAS2.5"MLCG3HSEnterpriseSSD 8

    00AJ212 A4UB 400GBSAS2.5"MLCG3HSEnterpriseSSD 8

    00AJ217 A4UC 800GBSAS2.5"MLCG3HSEnterpriseSSD 8

    00AJ222 A4UD 1.6TBSAS2.5"MLCG3HSEnterpriseSSD 8

    2.5"6GbSATAHSEnterpriseSSDs

    00AJ156 A4U3 S3700200GBSATA2.5"MLCG3HSEnterpriseSSD 8

    00vAJ161 A4U4 S3700400GBSATA2.5"MLCG3HSEnterpriseSSD 8

    00AJ166 A4U5 S3700800GBSATA2.5"MLCG3HSEnterpriseSSD 8

    2.5"6GbSATAHSEnterpriseValueSSDs

    00AJ395 A577 120GBSATA2.5"MLCG3HSEnterpriseValueSSD 8

    00AJ400 A578 240GBSATA2.5"MLCG3HSEnterpriseValueSSD 8

    00AJ405 A579 480GBSATA2.5"MLCG3HSEnterpriseValueSSD 8

    00AJ410 A57A 800GBSATA2.5"MLCG3HSEnterpriseValueSSD 8

    00FN278 A5U6 S35001.6TBSATA2.5"MLCG3HSEnterpriseValueSSD 8

  • 8/9/2019 Tips 1250

    26/59

    LenovoSystemx3850X6(6241) 26

    Table12.Diskdriveoptionsforinternaldiskstorage(Part2)

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    x3850 X6

    2.5"6GbSATAHSEntrySSDs

    00FN337 AS0G 240GBSATA2.5"MLCG3HSEntrySSD 8

    00FN342 AS0H 480GBSATA2.5"MLCG3HSEntrySSD 8

    00FN347 AS0J 960GBSATA2.5"MLCG3HSEntrySSD 8

    2.5"6GbNLSASHSHDDs

    00AJ121 A4TT 500GB7.2K6GbpsNLSAS2.5"G3HSHDD 8

    00AJ086 A4TU 1TB7.2K6GbpsNLSAS2.5''G3HSHDD 8

    2.5"6GbNLSATAHSHDDs

    00AJ131 A4TV 250GB7.2K6GbpsNLSATA2.5"G3HSHDD 8

    00AJ136 A4TW 500GB7.2K6GbpsNLSATA2.5"G3HSHDD 8

    00AJ141 A4TX 1TB7.2K6GbpsNLSATA2.5"G3HSHDD 8

    2.5"15K6GbSASHSHDDs

    00AJ126 A4TS 600GB15K6GbpsSAS2.5"G3HSHDD 8

    00AJ081 A4TR 300GB15K6GbpsSAS2.5"G3HSHDD 8

    00AJ111 A4TQ 146GB15K6GbpsSAS2.5"G3HSHDD 8

    2.5"10K6GbSASHSHDDs

    00AJ146 A4TP 1.2TB10K6GbpsSAS2.5"G3HSHDD 8

    00AJ071 A4TN 900GB10K6GbpsSAS2.5"G3HSHDD 8

    00AJ091 A4TM 600GB10K6GbpsSAS2.5"G3HSHDD 800AJ096 A4TL 300GB10K6GbpsSAS2.5"G3HSHDD 8

    2.5"6GbSASHSSEDs

    00AJ116 A4U2 146GB15K6GbpsSAS2.5"G3HSSED 8

    00AJ106 A4TY 300GB10K6GbpsSAS2.5"G3HSSED 8

    00AJ101 A4TZ 600GB10K6GbpsSAS2.5"G3HSSED 8

    00AJ076 A4U0 900GB10K6GbpsSAS2.5"G3HSSED 8

    00AJ151 A4U1 1.2TB10K6GbpsSAS2.5''G3HSSED 8

  • 8/9/2019 Tips 1250

    27/59

    LenovoSystemx3850X6(6241) 27

    Table12.Diskdriveoptionsforinternaldiskstorage(Part3)

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    x3850 X6

    2.5"12GbSASHSSSDs

    00FN379 AS7C 200GB12GSAS2.5"MLCG3HSEnterpriseSSD 8

    00FN389 AS7E 400GB12GSAS2.5"MLCG3HSEnterpriseSSD 8

    00FN399 AS7G 800GB12GSAS2.5"MLCG3HSEnterpriseSSD 8

    00FN409 AS7J 1.6TB12GSAS2.5"MLCG3HSEnterpriseSSD 8

    2.5"12GbSASHSEnterpriseSSDSEDs

    00FN419 AS7L 400GBSED12GSAS2.5"MLCG3HSEnterpriseSSD 8

    00FN424 AS7M 800GBSED12GSAS2.5"MLCG3HSEnterpriseSSD 8

    2.5"15K12GbSASHSHDDs

    00NA221 ASBB IBM300GB15K12GbpsSAS2.5"G3HS512eHDD 8

    00NA231 ASBD IBM600GB15K12GbpsSAS2.5"G3HS512eHDD 8

    2.5"10K12GbSASHSHDDs

    00NA241 ASBF 600GB10K12GbpsSAS2.5"G3HS512eHDD 8

    00NA251 ASBH 900GB10K12GbpsSAS2.5"G3HS512eHDD 8

    00NA261 ASBK 1.2TB10K12GbpsSAS2.5"G3HS512eHDD 8

    00NA271 ASBM 1.8TB10K12GbpsSAS2.5"G3HS512eHDD 8

    2.5"12GbSASHSSEDs

    00NA281 ASBP 300GB15K12GbpsSAS2.5"G3HS512eSED 8

    00NA286 ASBQ 600GB15K12GbpsSAS2.5"G3HS512eSED 800NA291 ASBR 600GB10K12GbpsSAS2.5"G3HS512eSED 8

    00NA296 ASBS 900GB10K12GbpsSAS2.5"G3HS512eSED 8

    00NA301 ASBT 1.2TB10K12GbpsSAS2.5"G3HS512eSED 8

    00NA306 ASBU 1.8TB10K12GbpsSAS2.5"G3HS512eSED 8

    2.5"15K12GbSASHSHybridHDDs

    00NA311 ASBV 300GB15K12GbpsSAS2.5"G3HS512eHybrid 8

    00NA321 ASBX 600GB15K12GbpsSAS2.5"G3HS512eHybrid 8

    Internal backup un its

    Theserverdoesnotsupportinternaltapedriveoptions.

    Optical dr ives

    Theserverdoesnotsupportaninternalopticaldriveoption,however,youcanconnectanexternalUSBopticaldrive.Seehttp://support.lenovo.com/en/documents/pd011281forinformationaboutavailableexternalopticaldrivesfromLenovo.

    http://support.lenovo.com/en/documents/pd011281http://support.lenovo.com/en/documents/pd011281

  • 8/9/2019 Tips 1250

    28/59

    LenovoSystemx3850X6(6241) 28

    I /O expansion options

    Theserversupportsupto11PCIeslotsplusdedicatedMezzanineLOMslot(12total)asfollows:

    IntheStorageBook(standardinallmodels):TwoPCIe3.0x8slotsforsupportedinternalRAIDcontrollersandSASHBAs

    InthePrimaryI/OBook(standardinallmodels):

    TwoPCIe3.0x16slots(x16-wired),halflength,fullheight,upto75WofpoweroOnePCIe3.0x16(x8-wired),halflength,fullheight,upto75WofpoweroOnemezzanineLOM2(ML2)slotfornetworkadapterswiththenewML2formfactor(PCIe3.0ox8)

    TwooptionalI/OBooks,eachwiththreeslots,allfullheight.OptionalI/OBooksareenabledforhot-swap.

    ThefollowingfigureshowsthePrimaryI/OBookwiththeairbaffleraisedtoshowtheinternals.

    Figure8.PrimaryI/OBook

    OptionalI/OBookscanbeeitherof:

    Half-lengthI/OBook:TwoPCIe3.0x8slots(x8wired)oOnePCIe3.0x16slot(x16wired)o

    Full-lengthI/OBook:TwoPCIe3.0x16(x16wired)oOnePCIe2.0x8slot(x4wired)o

  • 8/9/2019 Tips 1250

    29/59

    LenovoSystemx3850X6(6241) 29

    InorderforanI/OBooktobehot-swappable,alladaptersthatareinstalledinthebookmustsupporthot-swapandtheoperatingsystemmustalsosupporthot-swap.Theseoperatingsystemssupporthot-swap:

    WindowsServer2008R2WindowsServer2012WindowsServer2012R2

    Theadapterslistedinthefollowingtablesupporthot-swap.

    Table13.Adaptersthatsupporthotswap

    Part num ber Feature code Descript ion

    00D8540* A4XH EmulexDualPort10GbESFP+VFAIIIrforSystemx*

    49Y7960 A2EC IntelX520DualPort10GbESFP+AdapterforSystemx

    49Y7970 A2ED IntelX540-T2DualPort10GBaseTAdapterforSystemx

    49Y4230 5767 IntelEthernetDualPortServerAdapterI340-T2forSystemx

    49Y4240 5768 IntelEthernetQuadPortServerAdapterI340-T4forSystemx

    00AG500 A56K IntelI350-F11xGbEFiberAdapterforSystemx

    00AG510 A56L IntelI350-T22xGbEBaseTAdapterforSystemx

    00AG520 A56M IntelI350-T44xGbEBaseTAdapterforSystemx

    *Hot-swapisonlysupportedwhentheadapterisinpNICmode.Hot-swapisnotsupportedineithervNICmode(VirtualFabricmodeorSwitchIndependentmode).

    TheusageoftheseOptionalI/OBooksrequiresallfourprocessorstobeinstalled.

    ThefollowingtableshowstheorderinginformationfortheoptionalI/OBooks.

    Table14.I/OBookoptions

    Part

    number

    Feature

    code

    Descript ion M axim um

    suppor ted

    x3850 X6

    44X4049 A4A2 X6Half-LengthI/OBook 2

    44X4051 A4A3* X6Full-LengthI/OBook 2

    *TheFull-lengthI/OBookcanbeorderedonlyasanoption.ItisnotavailablethroughCTObecausetheFull-lengthI/OBookcannotbeshippedinstalledintheserver

  • 8/9/2019 Tips 1250

    30/59

    LenovoSystemx3850X6(6241) 30

    ThefollowingfigureshowsthetwooptionalI/OBooks,theHalf-lengthI/OBookandtheFull-lengthI/OBook.

    Figure9.Half-lengthI/OBookandtheFull-lengthI/OBook

    ThefollowingfigureshowstheinsideoftheHalf-lengthI/OBook.

    Figure10.Half-lengthI/OBook

    EachslotintheHalf-lengthI/OBookandtheFull-lengthI/OBooksuppliesupto75Wofpower.

    TheFull-lengthI/OBookalsoincludestwoauxiliarypowerconnectors.Withtheuseoftheseconnectorsandthesuppliedpowercords,theI/Obooksupportsonedouble-wideadapterupto300W.Theauxiliarypowerconnectorsareasfollows:

    One2x4powerconnector,whichsuppliesupto150WofadditionalpowertotheadapterOne2x3powerconnector,whichsuppliesupto75Wofadditionalpowertotheadapter

  • 8/9/2019 Tips 1250

    31/59

    LenovoSystemx3850X6(6241) 31

    ThecombinedpowerconsumptionofalltheadaptersthatareinstalledintheFull-lengthI/OBookcannotexceed300W.

    Note :The2x3connectorisintendedtobeusedonlywhenoneadapterisinstalledinthefirstx16slot(theup-mostslotinthefollowingfigure),eitherrequiring225Wor300Wofpower.Thelocationofthe2x3connectorpreventsanadapterfrombeinginstalledintheotherx16slot.

    Figure11.Full-lengthI/OBook

    TheHalf-lengthI/OBookinstallsflushwiththePrimaryI/OBookattherearoftheserver.TheFull-lengthI/OBook,wheninstalled,addsa99mm(3.9in.)mechanicalextensiontothebaselengthdimensionofthechassis.

    ThefollowingfigureshowsaFull-lengthI/OBookandaHalf-lengthI/OBookinstalledintheserver.

    Figure12.I/OBooksthatareinstalledinthex3850X6

  • 8/9/2019 Tips 1250

    32/59

    LenovoSystemx3850X6(6241) 32

    Network adapters

    TheserversupportsML2adaptersthatareinstalledinthecustomML2slot.Thisslotsupportsadapterswitheithertwo10GbportsorfourGigabitportsandsupportsdirectconnectivitytotheIMM2serviceprocessorforout-of-bandsystemsmanagement.

     AslistedinTable2,ModelB3xincludestheBroadcomNetXtremeIIML2DualPort10GbESFP+adapterasstandard.AllotherstandardmodelsincludeanIntelI350-T4ML2QuadPortGbEAdapter(I350-AM4based).

    TheBroadcomNetXtremeIIML2DualPort10GbESFP+Adapterhasthefollowingspecifications:

    Dual-port10GbEthernetconnectivityBroadcomBCM57810SASICSFP+portssupportingfiberopticanddirect-attachcopper(DAC)cables

    Formoreinformationaboutthisadapter,seetheLenovoPressProductGuidefoundatthefollowingaddress:http://lenovopress.com/tips1027

    TheIntelI350-T4ML2QuadPortGbEAdapterhasthefollowingspecifications:

    Quad-port1GbEthernetconnectivityIntelI350-AM4ASICRJ45portsforcoppercables

    Formoreinformationaboutthisadapter,seetheLenovoPressProductGuide:http://lenovopress.com/tips1155

    ThefollowingtableliststhesupportedML2adapters.

    Table15.ML2adapters

    P art n um b er F ea tu re

    code

    Description M axim um

    suppor ted

    x3850 X6

    00D2026 A40S BroadcomNetXtremeIIML2DualPort10GbaseTforSystemx 1

    00D2028 A40T BroadcomNetXtremeIIML2DualPort10GbESFP+forSystemx 1

    00D1996 A40Q EmulexVFA5ML2DualPort10GbESFP+AdapterforSystemx 1

    00D8544 A4NZ EmulexVFA5ML2FCoE/iSCSILicenseforSystemx(FoD)(FeaturesonDemandupgradefor00D1996-oneforeachadapter)

    1

    00D1998 A40R IntelI350-T4ML2QuadPortGbEAdapterforSystemx 1

    00D1994 A40P IntelX540ML2DualPort10GbaseTAdapterforSystemx 1

    94Y5200 AS74 IntelX710ML24x10GbESFP+AdapterforSystemx 100FP650 A5RK MellanoxConnectX-3ProML22x40GbE/FDRVPIAdapterforSystemx 1

    http://lenovopress.com/tips1027http://lenovopress.com/tips1155http://lenovopress.com/tips1155http://lenovopress.com/tips1027

  • 8/9/2019 Tips 1250

    33/59

    LenovoSystemx3850X6(6241) 33

    TheserveralsosupportsvariousotherEthernetandInfiniBandnetworkadapters,aslistedinthefollowingtable.ThemaximumquantitylistedisforconfigurationswithallprocessorsandI/Obooksinstalled.

    Table16.Networkadapters

    Part

    number

    Feature

    code

    Descript ion M axim um

    suppor ted

    x3850 X6

    40GbEthernet

    00D9550 A3PN MellanoxConnectX-340GbE/FDRIBVPIAdapterforSystemx 9

    10GbEthernet

    44T1370 A5GZ BroadcomNetXtreme2x10GbEBaseTAdapterforSystemx 9

    49Y7910 A18Y BroadcomNetXtremeIIDualPort10GBaseTAdapterforSystemx 9

    00JY820 A5UT EmulexVFA52x10GbESFP+PCIeAdapterforSystemx 9

    00JY830 A5UU EmulexVFA52x10GbESFP+AdapterandFCoE/iSCSISWforSystemx 9

    00JY824 A5UV EmulexVFA5FCoE/iSCSISWforPCIeAdapterforSystemx(FoD) 9

    00D8540 A4M9 EmulexDualPort10GbESFP+VFAIII-RforSystemx 9

    49Y7960 A2EC IntelX520DualPort10GbESFP+AdapterforSystemx 9

    49Y7970 A2ED IntelX540-T2DualPort10GBaseTAdapterforSystemx 9

    81Y3520 AS73 IntelX7102x10GbESFP+AdapterforSystemx 9

    00D9690 A3PM MellanoxConnectX-310GbEAdapterforSystemx 9

    90Y4600 A3MR QLogic8200DualPort10GbESFP+VFAforSystemx 9

    00Y5624 A3MT QLogic8200VFAFCoE/iSCSILicenseforSystemx(FoD) 9

    47C9952 A47H Solarf lareSFN5162F2x10GbESFP+PerformantAdapterforSystemx 9

    47C9960 A47J SolarflareSFN6122F2x10GbESFP+OnloadAdapterforSystemx 9

    GigabitEthernet

    90Y9370 A2V4 BroadcomNetXtremeIDualPortGbEAdapterforSystemx 9

    90Y9352 A2V3 BroadcomNetXtremeIQuadPortGbEAdapterforSystemx 9

    49Y4230 5767 IntelEthernetDualPortServerAdapterI340-T2forSystemx 9

    49Y4240 5768 IntelEthernetQuadPortServerAdapterI340-T4forSystemx 9

    00AG500 A56K IntelI350-F11xGbEFiberAdapterforSystemx 9

    00AG510 A56L IntelI350-T22xGbEBaseTAdapterforSystemx 9

    00AG520 A56M IntelI350-T44xGbEBaseTAdapterforSystemx 9

    InfiniBand

    00D9550 A3PN MellanoxConnectX-340GbE/FDRIBVPIAdapterforSystemx 9

    Formoreinformation,seethelistofLenovoPressProductGuidesintheNetworkingadapterscategoryfoundatthefollowingaddress:http://lenovopress.com/systemx/networkadapters

    http://lenovopress.com/systemx/networkadaptershttp://lenovopress.com/systemx/networkadapters

  • 8/9/2019 Tips 1250

    34/59

    LenovoSystemx3850X6(6241) 34

    Storage host bus adapters

    ThefollowingtablelistsstorageHBAsthataresupportedbythex3850X6.ThemaximumquantitylistedisforconfigurationswithallprocessorsandI/Obooksinstalled.ThemaximumquantitylistedisforconfigurationswithallprocessorsandI/Obooksinstalled.

    Table17.StorageadaptersPart num ber Feature

    code

    Description M axim um

    suppor ted

    x3850 X6

    FibreChannel-16Gb

    81Y1655 A2W5 Emulex16GbFCSingle-portHBAforSystemx 9

    81Y1662 A2W6 Emulex16GbFCDual-portHBAforSystemx 9

    81Y1668 A2XU Brocade16GbFCSingle-portHBAforSystemx 9

    81Y1675 A2XV Brocade16GbFCDual-portHBAforSystemx 9

    00Y3337 A3KW QLogic16GbFCSingle-portHBAforSystemx 9

    00Y3341 A3KX QLogic16GbFCDual-portHBAforSystemx 9

    FibreChannel-8Gb

    42D0485 3580 Emulex8GbFCSingle-portHBAforSystemx 9

    42D0494 3581 Emulex8GbFCDual-portHBAforSystemx 9

    42D0501 3578 QLogic8GbFCSingle-portHBAforSystemx 9

    42D0510 3579 QLogic8GbFCDual-portHBAforSystemx 9

    46M6049 3589 Brocade8GbFCSingle-portHBAforSystemx 9

    46M6050 3591 Brocade8GbFCDual-portHBAforSystemx 9

    SAS

    46C9010 A3MV N2125SAS/SATAHBAforSystemx 9

    00AE912 A5M0 N2225SAS/SATAHBAforSystemx 9

    Formoreinformation,seethelistofLenovoPressProductGuidesintheHostbusadapterscategoryfoundatthefollowingaddress:http://lenovopress.com/systemx/hba

    http://lenovopress.com/systemx/hbahttp://lenovopress.com/systemx/hba

  • 8/9/2019 Tips 1250

    35/59

    LenovoSystemx3850X6(6241) 35

    PCIe SSD adap ters

    TheserversupportstheHighIOPSSSDadaptersthatarelistedinthefollowingtable.ThemaximumquantitylistedisforconfigurationswithallprocessorsandI/Obooksinstalled.

    Table18.SSDadapters

    Partnum ber Featurecode

    Description M axim um

    suppor ted

    x3850 X6

    46C9078 A3J3 365GBHighIOPSMLCMonoAdapter Nine

    46C9081 A3J4 785GBHighIOPSMLCMonoAdapter Nine

    90Y4377 A3DY 1.2TBHighIOPSMLCMonoAdapter Nine

    90Y4397 A3DZ 2.4TBHighIOPSMLCDuoAdapter Nine

    00AE995 ARYP 1000GBEnterpriseio3FlashAdapter 6

    00AE998 ARYQ 1300GBEnterpriseio3FlashAdapter 6

    00JY004 ARYS* 5200GBEnterpriseio3FlashAdapter Nine

    00JY001 ARYR 2600GBEnterpriseio3FlashAdapter 6

    00AE983 ARYK 1250GBEnterpriseValueio3FlashAdapter 6

    00AE986 ARYL 1600GBEnterpriseValueio3FlashAdapter 6

    00AE989 ARYM 3200GBEnterpriseValueio3FlashAdapter 6

    00AE992 ARYN* 6400GBEnterpriseValueio3FlashAdapter Nine

    *TheseadapterscannotbeorderedviaCTO.Itcanonlybeorderedasanoption.Theservercannotbeshippedwiththisadapterinstalled.Seehttp://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-IO3

    Formoreinformationabouttheseadapters,seetheLenovoPressProductGuidesintheInternalStoragecategory:http://lenovopress.com/systemx/internalstorage

    http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-IO3http://lenovopress.com/systemx/internalstoragehttp://lenovopress.com/systemx/internalstoragehttp://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-IO3

  • 8/9/2019 Tips 1250

    36/59

    LenovoSystemx3850X6(6241) 36

    GPU adapters and co-processors

    Theserversupportstheco-processorsandgraphicsprocessingunits(GPUs)thatarelistedinthefollowingtable.EachisinstalledinaFull-lengthI/OBook.NootheradaptercanbeinstalledintheFull-lengthI/OBook.TheFull-lengthI/OBookincludesthenecessaryauxiliarypowercables.

    Notes:

    TheseadaptersarenotavailablethroughCTOandcannotbeshippedinstalledintheserverbecausetheyareinstalledintheFull-lengthI/OBook,whichextendsbeyondtherearofthechassis(seeFigure12).Theseadaptersmustbeshippedseparatelyfromtheserver.OrdertheadapterandFull-lengthI/OBookasseparateoptions.

    IfaNVIDIAGridK1,GridK2,TeslaK20,TeslaK40c,QuadroK4000orQuadroK6000isinstalled,themaximumsystemmemorythatcanbeinstalledis1TB.

    Table19.GPUadapters

    Part

    number

    Feature

    code

    Description M inim um

    system

    RAM

    Maximum

    suppor ted

    x3850 X6

    00FP670 A4G4* IntelXeonPhi3120A 12GB 2

    00J6160 A3GM* NVIDIAGRIDK1 32GB 2

    00FP674 A470* NVIDIAGridK2(ActivelyCooled) 16GB 2

    00FP675 A3YU* NVIDIAQuadroK4000 6GB 2

    00FP672 A3YV* NVIDIAQuadroK6000 24GB 2

    00FP673 A471* NVIDIATeslaK20(ActivelyCooled) 10GB 2

    00FP676 A5FG* NVIDIATeslaK40c 24GB 2

    *NotavailablethroughCTO.

  • 8/9/2019 Tips 1250

    37/59

    LenovoSystemx3850X6(6241) 37

    Powe r suppl ies

    Thex3850X6serversupportsuptofourredundantpowersupplies.Standardmodelscomewithone,two,orfourpowersupplies(modeldependent).Thefollowingtableliststhepowersupplies.

    Table20.Powersupplies

    Part num ber Feature code Description M axim um

    suppor ted

    x3850 X6

    Models

    where used

    44X4150 A54D 1400WHERedundantPowerSupplyforaltitudes>5000meters

    4 AllHANAmodels

    44X4152 A54E 1400WHERedundantPowerSupply 4 -

    44X4132 A4R0 900WPowerSupply 4 A4x,B1x,B3x,C1x,C4x

    88Y7433 A2EA 750WHighEfficiency-48VDCPowerSupply 4 -

     AnACpowersupplyshipsstandardwithone2.8mC13-C14powercord.

    Configurationrulesareasfollows:

    Powersuppliesmustbeinpairs(x3850X6)orquads(x3950X6),withtheexceptionofmodel3837-A4x,whereonepowersupplyissupported.

    TheACpowersuppliescanbemixed.Validcombinationsforthex3850X6forexample,are:

    Two44X4132andtwo44X4152Two44X4132andtwo44X4150

    Itisnotrecommendedyoumixthetwo1400Woptions(44X4152forlowaltitudeand44X4150forhighaltitude)asyouwillnullifythehigh-altitudecapabilitiesof44X4150.

    YoucannotmixtheACpowersupplieswiththeDCpowersupply

    UsethePowerConfiguratortodetermineexactlywhatpoweryourserverneeds:http://ibm.com/systems/bladecenter/resources/powerconfig.html

    Integrated virtualization

    TheserversupportsVMwareESXithatisinstalledonaUSBmemorykey.ThekeyisinstalledinaUSBsocketthatisontheprimaryI/Obookinsidetheserver.Thefollowingtableliststhevirtualizationoptions.

    Table21.Virtualizationoptions

    Part num ber Feature

    code

    Description M axim um

    suppor ted

    41Y8298 A2G0 BlankUSBMemoryKeyforVMwareESXiDownloads 1

    41Y8382 A4WZ USBMemoryKeyforVMwareESXi5.1U1 1

    http://ibm.com/systems/bladecenter/resources/powerconfig.htmlhttp://ibm.com/systems/bladecenter/resources/powerconfig.html

  • 8/9/2019 Tips 1250

    38/59

    LenovoSystemx3850X6(6241) 38

    Systems management

    TheservercontainsIntegratedManagementModuleII(IMM2),whichprovidesadvancedservice-processorcontrol,monitoring,andanalertingfunction.Ifanenvironmentalconditionexceedsathresholdorifasystemcomponentfails,theIMM2lightsLEDstohelpyoudiagnosetheproblem,recordstheerrorintheeventlog,andalertsyoutotheproblem.TheIMM2alsoprovidesavirtualpresence

    capabilityforremoteservermanagementcapabilities.

    TheIMM2providesremoteservermanagementthroughindustry-standardinterfaces:

    IntelligentPlatformManagementInterface(IPMI)Version2.0SimpleNetworkManagementProtocol(SNMP)Version3CommonInformationModel(CIM)Webbrowser

    Theremotepresenceprovidesthefollowingfunctions:

    Remotelyviewingvideowithgraphicsresolutionsupto1600x1200at75Hzwithupto23bitsperpixelcolors,regardlessofthesystemstate

    Remotelyaccessingtheserverbyusingthekeyboardandmousefromaremoteclient

    MappingtheCDorDVDdrive,diskettedrive,andUSBflashdriveonaremoteclient,andmappingISOanddisketteimagefilesasvirtualdrivesthatareavailableforusebytheserver

    UploadingadisketteimagetotheIMMmemoryandmappingittotheserverasavirtualdrive

    Theblue-screencapturefeaturecapturesthevideodisplaycontentsbeforetheIMMrestartstheserverwhentheIMMdetectsanoperating-systemhangcondition.Asystemadministratorcanusetheblue-screencapturefeaturetoassistindeterminingthecauseofthehangcondition.

    Supported operating systems

    Theserversupportsthefollowingoperatingsystems:

    MicrosoftWindowsServer2008R2MicrosoftWindowsServer2012MicrosoftWindowsServer2012R2RedHatEnterpriseLinux6Serverx64EditionRedHatEnterpriseLinux7SUSEEnterpriseLinuxServer(SLES)12SUSELINUXEnterpriseServer11forAMD64/EM64TSUSELINUXEnterpriseServer11withXenforAMD64/EM64TSUSELinuxEnterpriseServer12withXENVMwarevSphere5.1(ESXi)*VMwarevSphere5.5(ESXi)VMwarevSphere6.0(ESXi)*

    *SupportedonserverswithIntelXeonE7v2processorsonly

    Forthelatestinformationaboutthespecificversionsandservicelevelsthataresupportedandanyotherprerequisites,seetheServerProven®websiteatthefollowingaddress:http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

    http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtmlhttp://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

  • 8/9/2019 Tips 1250

    39/59

    LenovoSystemx3850X6(6241) 39

    Physical and electrical specifications

    Dimensionsandweight:

    Height:173mm(6.8in.)Width:482mm(19.0in.)

    Depth:804mm(31.6in)

    Depthwithcablemanagementbracketsinstalled:836mm(32.9”)DepthwithFull-lengthI/OBookinstalled:921mm(36.2in)Weight:

    Minimumconfiguration:35.9kg(79.2lb)oTypicalconfiguration:46.4kg(102.3lb)oMaximumconfiguration:54.7kg(120lb)o

    Supportedenvironment:

     Airtemperature:

    Serveron:5°Cto40°C(41°Fto104°F);altitude:0-3,050m(10,000ft).oServeroff:5°Cto45°C(41°Fto113°F);altitude:0-3,050m(10,000ft).oShipment:-40°Cto60°C(-40°Fto140°F)o

    Humidity:

    Serveron:8%-85%,maximumdewpoint24°CoServeroff:8%-85%,maximumdewpoint27°Co

    Electrical:

    Modelswith1400WACpowersupplies:o

    100-127(nominal)VAC;50Hzor60Hz;10A(900WDCoutput)200-240(nominal)VAC;50Hzor60Hz;8A(1400WDCoutput)Inputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.16kVAo Maximumconfiguration:3.2kVAo

    Modelswith900WACpowersupplies:o

    100-127(nominal)VAC;50Hzor60Hz;10.7A200-240(nominal)VAC;50Hzor60Hz;5.3AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.16kVAoMaximumconfiguration:2.0kVAo

    Modelswith750WDCpowersupplies:o

    -40to-75(nominal)VDCInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.16kVAoMaximumconfiguration:1.7kVAo

  • 8/9/2019 Tips 1250

    40/59

    LenovoSystemx3850X6(6241) 40

    BTUoutput:

    Minimumconfiguration:546Btu/hr(160watts)oMaximumconfiguration:10,912Btu/hr(3,200watts)o

    Noiselevel:

    6.6bels(operating)o6.4bels(idle)o

    Warranty options

    TheLenovoSystemx3850X6hasathree-yearwarrantywith24x7standardcallcentersupportand9x5NextBusinessDayonsitecoverage.AlsoavailableareLenovoServiceswarrantymaintenanceupgradesandpost-warrantymaintenanceagreements,withawell-definedscopeofservices,includingservicehours,responsetime,termofservice,andserviceagreementtermsandconditions.

    Lenovowarrantyserviceupgradeofferingsarecountry-specific.Notallwarrantyserviceupgradesareavailableineverycountry.FormoreinformationaboutLenovowarrantyserviceupgradeofferingsthatareavailableinyourcountry,visittheLenovoServiceswebsite:

    https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do

    Thefollowingtableexplainswarrantyservicedefinitionsinmoredetail.

    Table22.Warrantyservicedefinitions

    Term Description

    On-siteservice

     Aservicetechnicianwillarriveattheclient’slocationforequipmentservice.

    24x7x2hour Aservicetechnicianisscheduledtoarriveattheclient’slocationwithintwohoursafterremote

    problemdeterminationiscompleted.Lenovoprovidesservicearoundtheclock,everyday,includingLenovoholidays.

    24x7x4hour Aservicetechnicianisscheduledtoarriveattheclient’slocationwithinfourhoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservicearoundtheclock,everyday,includingLenovoholidays.

    9x5x4hour Aservicetechnicianisscheduledtoarriveattheclient’slocationwithinfourbusinesshoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservice8:00am-5:00pmintheclient'slocaltimezone,Monday-Friday,excludingLenovoholidays.Forexample,ifacustomerreportsanincidentat3:00pmonFriday,thetechnicianwillarriveby10:00amthefollowingMonday.

    9x5nextbusinessday

     Aservicetechnicianisscheduledtoarriveattheclient’slocationonthebusinessdayafterremoteproblemdeterminationiscompleted.Lenovoprovidesservice8:00am-5:00pmintheclient's

    localtimezone,Monday-Friday,excludingLenovoholidays.Callsreceivedafter4:00pmlocaltimerequireanextrabusinessdayforservicedispatch.Nextbusinessdayserviceisnotguaranteed.

    CommittedRepair

    Problemsreceivepriorityhandlingsothatrepairsarecompletedwithinthecommittedtimeof6,8,or24hours.Lenovoprovidesservice24hours/day,everyday,includingLenovoholidays.

    https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.dohttps://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do

  • 8/9/2019 Tips 1250

    41/59

    LenovoSystemx3850X6(6241) 41

    The following Lenovo warranty service upgrades are available:

    Warranty and maintenance service upgrades:

    Three, four, or five years of 9x5 or 24x7 service coverageOnsite response from next business day to 2 or 4 hoursCommitted repair service

    Warranty extension of up to 5 yearsPost warranty extensions

    Committed Repair Service

    Committed Repair Services enhances the level of Warranty Service Upgrade or PostWarranty/Maintenance Service offering associated with the selected systems. Offerings vary and areavailable in select countries.

    Priority handling to meet defined time frames to restore the failing machine to good workingcondition

    Committed repair service levels are measured within the following coverage hours:

    24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours24x7x8: Service performed 24 hours per day, 7 days per week, within 8 hours

    24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours

    Hard Drive Retention

    Lenovo’s Hard Drive Retention service is a multi-drive hard drive retention offering that ensures yourdata is always under your control, regardless of the number of hard drives that are installed in yourLenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drivewhile Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.The Hard Drive Retention service can be purchased in convenient bundles with our warrantyupgrades and extensions.

    Microcode Support

    Keeping microcode current helps prevent hardware failures and security exposure. There are twolevels of service: analysis of the installed base and analysis and update where required. Offerings

    vary by country and can be bundled with other warranty upgrades and extensions.

    Remote Technical Support Services (RTS)

    RTS provides comprehensive technical call center support for covered servers, storage, operatingsystems, and applications. Providing a single source for support of hardware and software issues,RTS can reduce problem resolution time, decreasing the cost to address technical problems andincreasing uptime. Offerings are available for Windows, Linux, IBM Systems Director, VMware,Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storagedevices.

  • 8/9/2019 Tips 1250

    42/59

    LenovoSystemx3850X6(6241) 42

    Regulatory compliance

    Theserverconformstothefollowingregulations:

    FCC-VerifiedtocomplywithPart15oftheFCCRules,ClassA

    CanadaICES-003,issue4,ClassA

    UL/IEC60950-1

    CSAC22.2No.60950-1

    NOM-019

     ArgentinaIEC60950-1

    JapanVCCI,ClassA

     Australia/NewZealandAS/NZSCISPR22,ClassA

    IEC60950-1(CBCertificateandCBTestReport)

    ChinaCCC(GB4943),GB9254ClassA,GB17625.1

    TaiwanBSMICNS13438,ClassA;CNS14336-1

    KoreaKN22,ClassA;KN24

    Russia/GOSTME01,IEC-60950-1,GOSTR51318.22,GOSTR51318.24,GOSTR51317.3.2,andGOSTR51317.3.3

    IEC60950-1(CBCertificateandCBTestReport)

    CEMark(EN55022ClassA,EN60950-1,EN55024,EN61000-3-2,andEN61000-3-3)

    CISPR22,ClassA

    TUV-GS(EN60950-1/IEC60950-1,EK1-ITB2000)

  • 8/9/2019 Tips 1250

    43/59

    LenovoSystemx3850X6(6241) 43

    External disk storage expansion

    Theserversupportsattachmenttoexternalstorageexpansionenclosures,suchastheEXP2500series,byusingtheServeRAIDM5225-2GBSAS/SATAControllerortheServeRAIDM5120SAS/SATAController.TheservercanalsobeattachedtosupportedexternalstoragesystemsbyusingasupportedHBA(seetheearlier"StorageHBA"section).ThefollowingtableshowstheRAIDcontrollersandoptions

    forexternaldiskstorageexpansion.

    Table23.RAIDcontrollersandoptionsforexternaldiskstorageexpansion

    Partnum ber Featurecode

    Description M axim um

    suppor ted

    x3850 X6

    Standard models

    where used

    00AE938 A5ND ServeRAIDM5225-2GBSAS/SATAController 3 -

    81Y4478 A1WX ServeRAIDM5120SAS/SATAController 2 -

    FeaturesonDemandupgradesfortheM5225

    47C8706 A3Z5 ServeRAIDM5200SeriesRAID6UpgradeforSystems-FoD

    1

    47C8710 A3Z7 ServeRAIDM5200SeriesPerformanceAcceleratorforSystems-FoD

    1

    47C8712 A3Z8 ServeRAIDM5200SeriesSSDCachingEnablerforSystems-FoD

    1

    HardwareupgradesfortheM5120

    81Y4487 A1J4 ServeRAIDM5100Series512MBFlash/RAID5Upgrade

    1 -

    81Y4559 A1WY ServeRAIDM5100Series1GBFlash/RAID5Upgrade 1 -

    FeatureonDemandupgradesfortheM5120

    90Y4318 A2MD ServeRAIDM5100SeriesSSDCachingEnabler 1* -

    90Y4273 A2MC ServeRAIDM5100SeriesSSDPerformanceKey 1* -

    81Y4546 A1X3 ServeRAIDM5100SeriesRAID6Upgrade 1* -

    *TheseM5120featuresupgradesrequireacachememoryupgrade(81Y4487or81Y4559).

    TheServeRAIDM5225SAS/SATAControllerhasthefollowingspecifications:

    Eightexternal12GbpsSAS/SATAportsSupports12,6,and3GbpsSASand6and3GbpsSATAdatatransferratesTwoexternalx4mini-SASHDconnectors(SFF-8644)Supports2GBflash-backedcache(standard)

    SupportsRAIDlevels0,1,5,10,and50(standard)

    SupportsRAID6and60withtheoptionalM5200SeriesRAID6UpgradeSupportsoptionalM5200SeriesPerformanceAcceleratorandSSDCachingupgradesPCIex8Gen3hostinterfaceBasedontheLSISAS310812GbpsROCcontrollerSupportsconnectivitytotheEXP2512andEXP2524storageexpansionenclosures

    FormoreinformationabouttheServeRAIDM5225,seetheLenovoPressProductGuideathttp://lenovopress.com/tips1258

    http://lenovopress.com/tips1258http://lenovopress.com/tips1258

  • 8/9/2019 Tips 1250

    44/59

    LenovoSystemx3850X6(6241) 44

    TheServeRAIDM5120SAS/SATAControllerhasthefollowingspecifications:

    Eightexternal6GbpsSAS/SATAportsUpto6GbpsthroughputperportTwoexternalx4mini-SASconnectors(SFF-8088)SupportsRAID0,1,and10SupportsRAID5and50withoptionalM5100SeriesRAID5upgradesSupportsRAID6and60withtheoptionalM5100SeriesRAID6upgradeSupports512MBor1GBflash-backedcachePCIe3.0x8hostinterfaceBasedontheLSISAS22086GbpsROCcontrollerSupportsconnectivitytotheEXP2512andEXP2524storageexpansionenclosures

    Cache upgrade required: TheServeRAIDM5120SAS/SATAControllershipsstandardwithoutacache.Oneoftheavailablecacheupgrades(81Y4487or81Y4559)isrequiredfortheM5120adapteroperations,anditmustbepurchasedtogetherwiththecontroller.

    FormoreinformationabouttheServeRAIDM5120,seetheLenovoPressProductGuideathttp://lenovopress.com/tips0858

    Thecontrollerssupportconnectivitytotheexternalexpansionenclosuresthatarelistedinthefollowingtable.Uptonineexpansionenclosurescanbedaisy-chainedperonecontrollerexternalport.Forbetterperformance,distributeexpansionenclosuresevenlyacrossbothcontrollerports.

    Table24.Externalexpansionenclosures

    Partnum ber Descript ion M axim um quant itysuppor ted per one contro l ler

    70F0/70F1 LenovoThinkServerSA120 8

    610012X EXP2512Express 18

    610024X EXP2524Express 9

    http://lenovopress.com/tips0858http://lenovopress.com/tips0858

  • 8/9/2019 Tips 1250

    45/59

    LenovoSystemx3850X6(6241) 45

    Lenovo ThinkServer SA120 support

    FordetailsaboutsupporteddrivesandcablesfortheLenovoThinkServerSA120,seetheLenovoPressProductGuide:http://lenovopress.com/tips1234

    EXP2512 and E XP2524 suppor t

    TheexternalSAScableslistedinthefollowingtablesupportconnectivitybetweenexternalexpansionenclosuresandthecontroller.

    Table25.ExternalSAScablesforexternalstorageexpansionenclosures

    Partnum ber Descript ion M axim um quantity supportedper one enclosure

    ServeRAIDM5120-ServertoExpansionenclosureconnectivity(Mini-SASx4toMini-SASx4)

    39R6529 1mSASCable 1

    39R6531 3mSASCable 1

    ServeRAIDM5225-ServertoExpansionenclosureconnectivity(Mini-SASHDx4toMini-SASx4)

    00MJ162 0.6mSASCable(mSASHDtomSAS) 1

    00MJ163 1.5mSASCable(mSASHDtomSAS) 1

    00MJ166 3mSASCable(mSASHDtomSAS) 1

    90Y7682 ExternalExpansionCable-6MSASCable-HDSAStoMiniSAS

    1

    ExpansionenclosuretoExpansionenclosureconnectivity(Mini-SASx4toMini-SASx4)

    39R6529 1mSASCable 1

    39R6531 3mSASCable 1

    ThefollowingtableliststhedrivesthataresupportedbyEXP2512externalexpansionenclosures.

    Table26.DriveoptionsforEXP2512externalexpansionenclosures

    Partnum ber Description M axim um quant ity supportedper one enclosure

    3.5"NLSASHSHDDs

    00NC555 2TB7,200rpm6GbSASNL3.5"HDD 12

    00NC557 3TB7,200rpm6GbSASNL3.5"HDD 12

    00NC559 4TB7,200rpm6GbSASNL3.5"HDD 12

    http://lenovopress.com/tips1234http://lenovopress.com/tips1234

  • 8/9/2019 Tips 1250

    46/59

    LenovoSystemx3850X6(6241) 46

    ThefollowingtableliststheharddiskdrivesthataresupportedbyEXP2524externalexpansionenclosures.

    Table27.DriveoptionsforEXP2524externalexpansionenclosures

    Partnum ber Description M axim um quant ity supportedper one enclosure

    2.5"NLSASHSHDDs

    00NC571 1TB7,200rpm6GbSASNL2.5"HDD 24

    2.5"SASHSHDDs

    00NC561 146GB15,000rpm6GbSAS2.5"HDD 24

    00NC563 300GB15,000rpm6GbSAS2.5"HDD 24

    00NC565 600GB10,000rpm6GbSAS2.5"HDD 24

    00NC567 900GB10,000rpm6GbSAS2.5"HDD 24

    00NC569 1.2TB10,000rpm6GbSAS2.5"HDD 24

    2.5"SASHSSSDs

    00NC573 200GB6GbSAS2.5"SSD 24

    00NC575 400GB6GbSAS2.5"SSD 24

  • 8/9/2019 Tips 1250

    47/59

    LenovoSystemx3850X6(6241) 47

    External disk storage system s

    ThefollowingtableliststheexternalstoragesystemsthataresupportedbytheserverandcanbeorderedthroughtheSystemxsaleschannel.Theservermightsupportotherdisksystemsthatarenotlistedinthistable.Formoreinformation,seetheIBMSystemStorageInteroperationCenterfoundathttp://www.ibm.com/systems/support/storage/ssic.

    Table28.Externaldiskstoragesystems

    Part num ber Description

    2071CU2 IBMStorwizeV3500LFFDualControlEnclosure

    2071CU3 IBMStorwizeV3500SFFDualControlEnclosure

    6099L2C IBMStorwizeV37003.5-inchStorageControllerUnit

    6099S2C IBMStorwizeV37002.5-inchStorageControllerUnit

    6099T2C IBMStorwizeV37002.5-inchDCStorageControllerUnit

    6194L2C IBMStorwizeV5000LFFControlEnclosure

    6194LEU IBMStorwizeV5000LFFExpansionEnclosure

    6194S2C IBMStorwizeV5000SFFControlEnclosure

    6194SEU IBMStorwizeV5000SFFExpansionEnclosure

    6195SC5 IBMStorwizeV70002.5-inchStorageControllerUnit

    6195LEF IBMStorwizeV70003.5-inchStorageExpansionUnit

    6195SEF IBMStorwizeV70002.5-inchStorageExpansionUnit

    Formoreinformation,seethelistofLenovoPressProductGuidesintheSystemStoragecategoryfound

    athttp://lenovopress.com/systemx/externalstorage

    http://www.ibm.com/systems/support/storage/ssic.http://www.ibm.com/systems/support/storage/ssic.http://lenovopress.com/systemx/externalstoragehttp://lenovopress.com/systemx/externalstoragehttp://www.ibm.com/systems/support/storage/ssic.

  • 8/9/2019 Tips 1250

    48/59

    LenovoSystemx3850X6(6241) 48

    External backup units

    Theserversupportstheexternalbackupattachmentoptionsthatarelistedinthefollowingtable.

    Table29.Externalbackupoptions(Part1)

    Part num ber Description

    Externaltapeexpansionenclosuresforinternaltapedrives

    87651UX 1UTapeDriveEnclosure

    8767HHX HalfHighTapeDriveEnclosure

    87651NX 1UTapeDriveEnclosure(withNema5-15PLineCord)

    8767HNX HalfHighTapeDriveEnclosure(withNema5-15PLineCord)

    Tapeenclosureadapters(withcables)

    40K2599 SASEnclosureAdapterKit

    Internalbackupdrivessupportedbyexternaltapeenclosures

    49Y9898 HalfHighLTOGen5InternalSASTapeDrive

    00D8924 HalfHighLTOUltriumGen6InternalSASTapeDrive

  • 8/9/2019 Tips 1250

    49/59

    LenovoSystemx3850X6(6241) 49

    Table29.Externalbackupoptions(Part2)

    Part num ber Description

    Externalbackupunits*

    36251TY RDXExternalUSB3.0Dockwith1TBCartridge

    362532Y RDXExternalUSB3.0Dockwith320GBCartridge

    362550Y RDXExternalUSB3.0Dockwith500GBCartridge

    3628L3X HalfHighLTOGen3ExternalSASTapeDrive(withUSpowercord)

    3628L4X HalfHighLTOGen4ExternalSASTapeDrive(withUSpowercord)

    3628L5X HalfHighLTOGen5ExternalSASTapeDrive(withUSpowercord)

    3628N3X HalfHighLTOGen3ExternalSASTapeDrive(withoutpowercord)

    3628N4X HalfHighLTOGen4ExternalSASTapeDrive(withoutpowercord)

    3628N5X HalfHighLTOGen5ExternalSASTapeDrive(withoutpowercord)

    3580S3V SystemStorageTS2230TapeDriveExpressModelH3V

    3580S4V SystemStorageTS2240TapeDriveExpressModelH4V

    3580S5E SystemStorageTS2250TapeDriveExpressModelH5S

    3580S5X SystemStorageTS2350TapeDriveExpressModelS53

    3572S4R TS2900TapeLibrarywithLTO4HHSASdrive&rackmountkit

    3572S5R TS2900TapeLibrarywithLTO5HHSASdrive&rackmountkit

    35732UL TS3100TapeLibraryModelL2UDriveless

    35734UL TS3200TapeLibraryModelL4UDriveless

    46X2682† LTOUltrium5FibreChannelDrive

    46X2683† LTOUltrium5SASDriveSled

    46X2684† LTOUltrium5HalfHighFibreDriveSled

    46X2685† LTOUltrium5Half HighSASDriveSled

    *Note:TheexternaltapedrivesthatarelistedcanbeorderedthroughtheSystemxsaleschannel.Theservermightsupportothertapedrivesthatarenotlistedinthistable.Formoreinformation,seetheIBMSystemStorageInteroperabilityCenter.

    †Note:Thesepartnumbersarethetapedrivesoptionsfor35732ULand35734UL.

    Formoreinformation,seethelistofLenovoPressProductGuidesintheBackupunitscategoryfoundatthefollowingaddress:http://lenovopress.com/systemx/tape

    http://lenovopress.com/systemx/tapehttp://lenovopress.com/systemx/tape

  • 8/9/2019 Tips 1250

    50/59

    LenovoSystemx3850X6(6241) 50

    Top-o f-rack Ethernet switches

    Theserversupportsthetop-of-rackEthernetswitchesthatarelistedinthefollowingtable.

    Table30.Top-of-rackswitches

    Part num ber Description

    1Gbtop-of-rackswitches

    7159BAX LenovoRackSwitchG7028(ReartoFront)

    7159CAX LenovoRackSwitchG7052(ReartoFront)

    715952F LenovoRackSwitchG8052(FronttoRear)

    7159G52 LenovoRackSwitchG8052(ReartoFront)

    10Gbtop-of-rackswitches

    7159BF7 LenovoRackSwitchG8124E(FronttoRear)

    7159BR6 LenovoRackSwitchG8124E(ReartoFront)

    715964F LenovoRackSwitchG8264(FronttoRear)

    7159G64 LenovoRackSwitchG8264(ReartoFront)

    7159DFX LenovoRackSwitchG8264CS(FronttoRear)

    7159DRX LenovoRackSwitchG8264CS(ReartoFront)

    7159CFV LenovoRackSwitchG8272(FronttoRear)

    7159CRW LenovoRackSwitchG8272(ReartoFront)

    7159GR5 LenovoRackSwitchG8296(FronttoRear)

    7159GR6 LenovoRackSwitchG8296(ReartoFront)

    40Gbtop-of-rackswitches

    7159BFX LenovoRackSwitchG8332(FronttoRear)

    7159BRX LenovoRackSwitchG8332(ReartoFront)

    Formoreinformation,seethelistofLenovoPressProductGuidesintheTop-of-rackswitchescategory:http://lenovopress.com/systemx/tor

    http://lenovopress.com/systemx/torhttp://lenovopress.com/systemx/tor

  • 8/9/2019 Tips 1250

    51/59

    LenovoSystemx3850X6(6241) 51

    Uninterruptible po wer sup ply units

    Theserversupportsattachmentstotheuninterruptiblepowersupply(UPS)unitsthatarelistedinthefollowingtable.

    Table31.Uninterruptiblepowersupplyunits

    Part num ber Description

    Rack-mountedortowerUPSunits

    55941AX RT1.5kVA2URackorTowerUPS(100-125VAC)

    55941KX RT1.5kVA2URackorTowerUPS(200-240VAC)

    55942AX RT2.2kVA2URackorTowerUPS(100-125VAC)

    55942KX RT2.2kVA2URackorTowerUPS(200-240VAC)

    55943AX RT3kVA2URackorTowerUPS(100-125VAC)

    55943KX RT3kVA2URackorTowerUPS(200-240VAC)

    55945KX RT5kVA3URackorTowerUPS(200-240VAC)

    55946KX RT6kVA3URackorTowerUPS(200-240V