Tips 1242

Embed Size (px)

Citation preview

  • 8/9/2019 Tips 1242

    1/57

    LenovoSystemx3500M5 1

    Lenovo System x3500 M5Lenovo Press Product Guide

    TheLenovoSystemx3500M5serverprovidesoutstandingperformanceforyourbusiness-criticalapplications.Itsenergy-efficientdesignsupportsmorecores,memory,anddatacapacityinascalableToweror5URackpackagethatiseasytoserviceandmanage.WithmorecomputingpowerperwattandthelatestIntelXeonE5-2600v3processors,youcanreducecostswhilemaintainingspeedandavailability.

    Suggesteduse:business-criticalworkloads,cloudcomputing,virtualization,virtualdesktop,bigdata,analytics,SAPapplications,databasemanagement,pointofsale

    Figure1showstheSystemx3500M5.

    Figure1.TheLenovoSystemx3500M5

    Did you know?

    Thex3500M5offersaflexible,scalabledesignandsimpleupgradepathto32HDDs,withuptosevenPCIe3.0slotsandupto1.5TBofmemory.TheonboardEthernetsolutionprovidesfourstandardintegratedGigabitEthernetportswithoutoccupyingPCIeslots.Comprehensivesystemsmanagementtoolswiththenext-generationIntegratedManagementModuleIImakeiteasytodeploy,integrate,service,andmanage.

  • 8/9/2019 Tips 1242

    2/57

    LenovoSystemx3500M5 2

    Key features

     Ahigh-performancedual-sockettowerserver,theLenovoSystemx3500M5candeliverthescalability,reliableperformance,andoptimizedefficiencyforyourbusiness-criticalapplications.Startwiththebasicsandupgradeasyourbusinesschangeswithoutjeopardizingexistinginvestments.VirtualizingthePCinfrastructureintooneservercanprovideaccesstoapowerfulserverwithabundantstoragespace,while

    significantlyreducingITcosts.

    Scalabi l i ty and performance

    Thex3500M5offersthefollowingfeaturestoboostperformance,improvescalability,andreducecosts:

    Improvesproductivitybyofferingsuperiorsystemperformancewithuptotwoprocessors(eachwith

    upto18cores),upto45MBofL3cache,andupto9.6GT/sQPIinterconnectlinks. 

    Supportsuptotwoprocessors,36cores,and72threadsmaximizetheconcurrentexecutionofmulti-threadedapplications.

    IntelligentandadaptivesystemperformancewithenergyefficientIntelTurboBoostTechnologyallowsCPUcorestorunatmaximumspeedsduringpeakworkloadsbytemporarilygoingbeyond

    processorthermaldesignpower(TDP).IntelHyper-ThreadingTechnologyboostsperformanceformultithreadedapplicationsbyenablingsimultaneousmultithreadingwithineachprocessorcore,uptotwothreadspercore.

    IntelVirtualizationTechnologyintegrateshardware-levelvirtualizationhooksthatallowoperatingsystemvendorstobetterusethehardwareforvirtualizationworkloads.

    IntelAdvancedVectorExtensions2.0(AVX2.0)enableaccelerationofenterprise-classworkloads,includingdatabases,andenterpriseresourceplanning.

    Upto2133MHzmemoryspeedswithtwoDIMMsperchannelthatarerunningat2133MHztohelpmaximizesystemperformance.

    Upto1.5TBofmemorycapacitywith64GBload-reducedDIMMs,orLRDIMMs(supportfor64GBLRDIMMsisplannedforalaterdate).

    The12GbpsSASinternalstorageconnectivitydoublesthedatatransferratecomparedto6GbSASsolutionstomaximizeperformanceofstorageI/O-intensiveapplications.

    Upto32drivebayswithinternalbackupandopticaldriveatthesametimeprovideaflexibleandscalableall-in-oneplatformtomeetincreasingdemands.

    Flexibleandscalableinternalstorageconfigurationsprovideforupto72TBofstoragecapacity.

    Theuseofsolid-statedrives(SSDs)insteadoforalongwithtraditionalspinningharddiskdrives(HDDs)cansignificantlyimproveI/Operformance.AnSSDcansupportupto100timesmoreI/Ooperationspersecond(IOPS)thanatypicalHDD.

    TheserverhasfourintegratedGigabitEthernetports.

    TheserveroffersuptosevenPCIExpress(PCIe)3.0I/Oexpansionslots.

    WithIntelIntegratedI/OTechnology,thePCIExpress3.0controllerisintegratedintotheIntelXeonprocessorE5family.ThisintegrationhelpstodramaticallyreduceI/Olatencyandincreaseoverallsystemperformance.

    SupportforuptotwoNVIDIAQuadrographicsprocessingunits(GPUs)tomaximizecomputingpower.

  • 8/9/2019 Tips 1242

    3/57

    LenovoSystemx3500M5 3

    Avai labi l i ty and serviceabi l ity

    Thex3500M5providesthefollowingfeaturestosimplifyserviceabilityandincreasesystemuptime:

    TheserveroffersChipkill,memorymirroring,andmemoryranksparingforredundancyintheeventofanon-correctablememoryfailure.

    Tool-lesscoverremovalprovideseasyaccesstoupgradesandserviceableparts,suchasCPU,memory,andadaptercards.

    Offershot-swapdrivesthatsupportRAIDredundancyfordataprotectionandgreatersystemuptime.

    Supportstheabilitytohaveredundanthot-swappowersuppliesandredundanthot-swapfanstoprovideavailabilityforbusiness-criticalapplications.

    TheoptionallightpathdiagnosticspanelandindividuallightpathLEDsquicklyleadthetechniciantofailed(orfailing)components.Thisfeaturesimplifiesservicing,speedsupproblemresolution,andhelpsimprovesystemavailability.

    PredictiveFailureAnalysis(PFA)detectswhensystemcomponents(processors,VRMs,memory,disks,fans,andpowersupplies)operateoutsideofstandardthresholdsandgeneratesproactivealertsinadvanceofpossiblefailure,whichincreasesuptime.

    SSDsoffersignificantlybetterreliabilitythantraditionalmechanicalHDDsforgreateruptime.

    Built-inIntegratedManagementModuleII(IMM2.1)continuouslymonitorssystemparameters,triggersalerts,andperformsrecoveryactionsifthereisafailuretominimizedowntime.

    Built-indiagnosticsbyusingDynamicSystemsAnalysis(DSA)Prebootspeedsuptroubleshootingtaskstoreduceservicetime.

    Three-yearcustomerreplaceableunitandonsitelimitedwarranty;nextbusinessday9x5.Optionalserviceupgradesavailable.

    Manage abi l i ty and securi ty

    Thefollowingpowerfulsystemsmanagementfeaturessimplifylocalandremotemanagementofthex3500M5:

    TheserverincludesanIMM2.1tomonitorserveravailabilityandperformremotemanagement.

    Integratedindustry-standardUnifiedExtensibleFirmwareInterface(UEFI)enablesimprovedsetup,configuration,andupdatesandsimplifieserrorhandling.

    TwointegratedTrustedPlatformModules(TPMs)enableadvancedcryptographicfunctionality,suchasdigitalsignaturesandremoteattestation.

    SystemxTrustedPlatformAssurance,anexclusivesetofSystemxsecurityfeaturesandpractices,establishesafoolproofsecurityfoundationforworkloadsbydeliveringfirmwarethatissecurelybuilt,tested,digitallysigned,andverifiedbeforerunning.

    Theserveroffersenterprise-classdataprotectionwithoptionalself-encryptingdrivesandsimple,centralizedkeymanagementthroughIBMSecurityKeyLifecycleManagement.

    Industry-standardAESNIsupportoffersfaster,strongerencryption.

    IBMSystemsDirectorofferscomprehensivesystemsmanagementtoolsthathelptoincreaseuptime,reducecosts,andimproveproductivitythroughadvancedservermanagementcapabilities.

  • 8/9/2019 Tips 1242

    4/57

    LenovoSystemx3500M5 4

    IntelExecuteDisableBitfunctionalitycanhelppreventcertainclassesofmaliciousbufferoverflowattackswhencombinedwithasupportingoperatingsystem.

    IntelTrustedExecutionTechnologyprovidesenhancedsecuritythroughhardware-basedresistancetomalicioussoftwareattacks,whichallowsanapplicationtoruninitsownisolatedspacethatisprotectedfromallothersoftwarerunningonasystem.

    Energy eff ic iency

    Thex3500M5offersthefollowingenergy-efficiencyfeaturestosaveenergy,reduceoperationalcosts,increaseenergyavailability,andcontributetothegreenenvironment:

    Energy-efficientplanarcomponentshelploweroperationalcosts.

    High-efficiencypowersupplieswith80PLUSPlatinumandTitaniumcertifications.

    IntelIntelligentPowerCapabilitypowersindividualprocessorelementsonandoffasneededtoreducepowerdraw.

    TheIntelXeonprocessorE5-2600v3productfamiliesoffersignificantlybetterperformanceoverthepreviousgenerationwhilefittingintothesamethermaldesignpower(TDP)limits.

    IntelIntelligentPowerCapabilitypowersindividualprocessorelementsonandoffasneededto

    reducepowerdraw.

    Low-voltageIntelXeonprocessorsdrawlessenergytosatisfydemandsofpowerandthermallyconstraineddatacentersandtelecommunicationenvironments.

    Low-voltage1.2VDDR4memoryDIMMsuseupto20%lessenergycomparedto1.35VDDR3DIMMs.

    SSDsuseasmuchas80%lesspowerthantraditionalspinning2.5-inchHDDs.

    Theserveruseshexagonalventilationholes,whichisapartofCalibratedVectoredCooling™technology.Hexagonalholescanbegroupedmoredenselythanroundholes,whichprovidesmoreefficientairflowthroughthesystem.

    IBMSystemsDirectorActiveEnergyManager™providesadvanceddatacenterpowernotificationand

    managementtohelpachievelowerheatoutputandreducedcoolingneeds.

  • 8/9/2019 Tips 1242

    5/57

    LenovoSystemx3500M5 5

    Locat ions of key components and connectors

    Thefollowingfigureshowsthefrontoftheserver.

    Figure2.FrontviewoftheSystemx3500M5

  • 8/9/2019 Tips 1242

    6/57

    LenovoSystemx3500M5 6

    Thefollowingfigureshowstherearoftheserver.

    Figure3.RearviewoftheSystemx3500M5

    Thefollowingfigureshowsthelocationsofkeycomponentsinsidetheserver.

    Figure4.InsideviewoftheSystemx3500M5

  • 8/9/2019 Tips 1242

    7/57

    LenovoSystemx3500M5 7

    Standard specif ications

    Thefollowingtableliststhestandardspecifications.

    Table1.Standardspecifications(part1)

    Com ponents Specificat ion

    Machinetype 5464

    Formfactor Toweror5URack.

    Processor UptotwoIntelXeonprocessorE5-2600v3productfamilyCPUswith18cores(2.8GHzcorespeeds);or14cores(2.6GHz),12cores(upto2.6GHz),10cores(2.3GHz),8cores(upto3.2GHz),6cores(upto2.4GHz),4cores(3.0GHz)

    TwoQPIlinksupto9.6GT/seach.Upto2133MHzmemoryspeed.Upto45MBL3cache.

    Chipset IntelC612.

    Memory Upto24DIMMsockets(12DIMMsperprocessor).RDIMMsandLRDIMMsaresupported.Memorytypescannotbeintermixed.Memoryspeedupto2133MHz.

    Memorymaximums

    WithRDIMMs:Upto384GBwith24x16GBRDIMMsandtwoprocessorsWithLRDIMMs:Upto1.5TBwith24x64GBLRDIMMsandtwoprocessors

    Memoryprotection

    ECC,Chipkill(forx4-basedmemoryDIMMs),memorymirroring,andmemoryranksparing

    Diskdrivebays Availableconfigurations:Upto32x2.5-inchhot-swapSAS/SATAHDDs

    Upto12x3.5-inchhot-swapSAS/SATAHDDsorSSDs

    Upto6x3.5-inchhot-swapHDDs+16x2.5-inchhot-swapdrivesHDDs/SSDs

    Upto6x3.5-inchsimple-swapSATAHDDs

     Additionaldrivebaysfortheaboveconfigurations:Two5.25-inchdrivebaysforopticaldrives

    Maximuminternalstorage

    72TBwith12x6TB3.5-inchNLSASorNLSATAhot-swapHDDs

    51.2TBwith32x1.6TB2.5-inchSAShot-swapSSDs

    38.4TBwith32x1.2TB2.5-inchSAShot-swapHDDs

    36TBwith6x6TB3.5-inchNLSASorNLSATAsimple-swapHDDs

    IntermixofSASandSATAissupported.

    Storagecontroller

    Onboard6GbSATA:noRAIDsupport

    12GbSAS/SATARAID:RAID0,1,10withM1215orM5210.OptionalupgradetoRAID5,50isavailableforM1215.OptionalupgradetoRAID5,50isavailableforM5210(zero-cache;1GBnon-backedcache;1GB,2GBor4GBflash-backedcache).OptionalupgradetoRAID6,60isavailableforM5210withmemorycacheupgrades.12GbSAS/SATAnon-RAID:N2215HBA

    Opticaldrivebays

    Twohalf-height5.25-inchbaysforopticalortapedrives.SupportsDVD-ROMorMultiburner.

    Tapedrivebays Twohalf-height5.25-inchbaysforopticalortapedrives.SupportforoneRDXinternalUSB

    tapedrive.

    Networkinterfaces

    FourintegratedGigabitEthernet1000BASE-Tports(RJ-45)basedonBroadcomBCM5719controller

  • 8/9/2019 Tips 1242

    8/57

    LenovoSystemx3500M5 8

    Table1.Standardspecifications(part2)

    Com ponents Specification

    PCIExpansionslots

    UptosevenslotswithtwoprocessorsandfourslotswhenoneCPUisinstalled.AllslotsarePCIe3.0slots:

    Slot1:PCIe3.0x8(x8wired);full-height,half-length

    Slot2:PCIe3.0x16(x8wired);full-height,full-lengthSlot3:PCIe3.0x16(x16wired);full-height,full-length

    Slot4:PCIe3.0x8(x8wired);full-height,full-length

    Slot5:PCIe3.0x8(x8wired);full-height,half-length(requiressecondprocessor)

    Slot6:PCIe3.0x16(x16wired);full-height,full-length(requiressecondprocessor)

    Slot7:PCIe3.0x16(x16wired)full-height,full-length(requiressecondprocessor)

    Slots3and6supportdouble-wideGPUs

    Ports Front:TwoUSB2.0ports

    Rear:FourUSBports(twoUSB2.0,twoUSB3.0),oneDB-15video,oneRJ-45systemsmanagement,fourRJ-45GbEnetworkports,optionalserialport.

    Internal:TwointernalUSB3.0ports(forembeddedhypervisorandinternaltapedrive).OptionalSDMediaAdapter.

    Cooling CalibratedVectoredCoolingwithuptofourhot-swapfans(twofansshippedstandardonsingleprocessormodelsandfourfansshippedondualprocessormodels).Forsingle-processormodels,optionalRedundantCoolingKitprovidestwoextrafansforN+1redundancy.

    Powersupply Uptotworedundanthot-swap550W,750Wor900WHighEfficiencyPlatinumACpowersupplies,or750WHighEfficiencyTitaniumACpowersupplies.

    Hot-swapparts Harddrives,powersupplies,andfans

    Systemsmanagement

    UEFI,IMM2.1thatisbasedonRenesasSH7758,PredictiveFailureAnalysis,lightpathdiagnosticspanelonthefrontoftheserverwithoptionalupgradekit,AutomaticServerRestart,ToolsCenter,SystemsDirectorandActiveEnergyManager.OptionalIMMAdvancedUpgradesoftwarefeatureforremotepresence.

    Securityfeatures Power-onpassword,administrator'spassword,twoTPMs:OntheIMM2.1(TPM1.2)andonthehost(TPM1.2/2.0).Lockablefrontbezel.

    Video MatroxG200eR2with16MBmemoryintegratedintotheIMM2.1.Maximumresolutionis1600x1200at75Hzwith16Mcolors.

    Operatingsystemssupported

    MicrosoftWindowsServer2012R2,2012and2008R2,RedHatEnterpriseLinux6and7,SUSELinuxEnterpriseServer11,VMwarevSphere(ESXi)5.1and5.5.

    Limitedwarranty Three-yearcustomer-replaceableunitandonsitelimitedwarrantywith9x5/NBD.

    Serviceandsupport

    OptionalserviceupgradesareavailablethroughLenovo:4-houror2-hourresponsetime,8-hourfixtime,1-yearor2-yearwarrantyextension,remotetechnicalsupportforLenovohardwareandselectedLenovoandthird-party(Microsoft,Linux,VMware)software.

    Dimensions Tower:Width:218mm(8.6in),depth:720mm(28.3in),height:440mm(17.25in).Withrackconversionkit:Width:423mm(16.6in),depth:706mm(27.8in),height:218mm

    (8.6in)Weight Tower:45.5kg(100.3lb)fullyconfigured,30.8kg(67.9lb)minimumconfiguration

    Withrackconversionkit:44.2kg(97.4lb)fullyconfigured,29.5kg(65lb)minimumconfiguration

  • 8/9/2019 Tips 1242

    9/57

    LenovoSystemx3500M5 9

    Thex3500M5serversareshippedwiththefollowingitems:

    StatementofLimitedWarrantyImportantNoticesRegistrationflyerDocumentationCDthatcontainstheInstallationandUser'sGuideOne2.8mC13linecord(country-specific)

    Notes: Rackmodelsincludearailkitbutdonotincludeacablemanagementarm.OrdertheCMAseparatelybyusingpartnumber00KC334.EMEAmodelsdonotcontainlinecord.Itmustbepurchasedseparately.

    Standard models

    Thefollowingtableliststhestandardmodels.

    Table2.Standardmodels

    M T M * In te l X e on p ro ce ss o rs †

      two maximum)

    M em ory R AID D rive bays

     std / max)

    D riv es S lots

     std /

    max)

    G bE O ptical Pow er

    supply

     std / max)

    Towermodels

    5464- A2x

    1xE5-2603v36C1.6GHz15MB1600MHz85W

    1x8GB M1215 8x2.5-inchHS/32

    Open 4/7 4 DVD 1x550WHS/2

    5464-B2x

    1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB M1215 8x2.5-inchHS/32

    Open 4/7 4 DVD 1x550WHS/2

    5464-C2x

    1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB M1215 8x2.5-inchHS/32

    Open 4/7 4 DVD 1x550WHS/2

    5464-C4x

    1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB M1215 6x3.5-inchHS/12

    Open 4/7 4 DVD 1x550WHS/2

    5464-

    D2x

    1xE5-2630v38C2.4GHz

    20MB1866MHz85W

    1x16GB M1215 8x2.5-inch

    HS/32

    Open 4/7 4 DVD 1x550W

    HS/2

    5464-G2x

    1xE5-2650v310C2.3GHz

    25MB2133MHz105W

    1x16GB M52101GBFlash

    8x2.-inchHS/32

    Open 4/7 4 DVD 1x750WHS/2

    5464-H2x

    1xE5-2670v312C2.3GHz

    30MB2133MHz120W

    1x16GB M52102GBFlash

    8x2.5-inchHS/32

    Open 4/7 4 DVD 1x900WHS/2

    5464-J2x

    1xE5-2680v312C2.5GHz

    30MB2133MHz120W

    1x16GB M52102GBFlash

    8x2.5-inchHS/32

    Open 4/7 4 DVD 1x900WHS/2

    Rackmodels

    5464-C3x

    1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB M1215 6x3.5-inchHS/12

    Open 4/7 4 DVD 1x550WHS/2

    5464-G3x

    1xE5-2650v310C2.3GHz

    25MB2133MHz105W

    1x16GB M52101GBFlash

    8x2.5-inchHS/32

    Open 4/7 4 DVD 1x750WHS/2

    *xintheMachineTypeModel(MTM)representsacountry-specificletter(forexample,theEMEAMTMis7983-A5G,andtheUSMTMis7383-A5U).AskaLenovorepresentativeforspecificinformation.†Processordetail:Processorquantityandmodel,cores,corespeed,L3cache,memoryspeed,TDP.

    RefertotheSpecificationssectionforinformationaboutstandardfeaturesoftheserver.

  • 8/9/2019 Tips 1242

    10/57

    LenovoSystemx3500M5 10

    TopSel ler and Express models

    Thefollowingtableliststheexpressmodels.

    Table3.Expressmodels(Part1)

    MTM**

    Form

    factor

    Intel Xeon processors†

      two maximum)

    M emory R AID D rive

    bays

     std / max)

    D rives Slots

     std /

    max)

    O ptica l Pow er

    supply

     2 max)

    UnitedStatesandCanada

    5464-EAUTower

    1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB M1215 6x3.5-inchHS/12

    Open 4/7 Multi-burner

    1x550W

    5464-EBUTower

    1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB M5120 6x3.5-inchHS/12

    Open 4/7 Multi-burner

    1x750W

    5464-ECUTower

    1xE5-2640v38C2.6GHz20MB1866MHz90W

    1x16GB M5120 8x2.5-inchHS/32

    Open 4/7 Multi-burner

    1x750W

    5464-EDUTower

    2xE5-2609v36C1.9GHz15MB1600MHz85W

    2x16GB M51202GBFlash

    6x3.5-inchHS/12

    Open 4/7 Multi-burner

    2x550W

    5464-EEUTower 2xE5-2640v38C2.6GHz20MB1866MHz90W 2x16GB M51202GBFlash 8x2.5-inchHS/32 Open 4/7 Multi-burner 2x750W

    Europe,MiddleEast&Africa(EMEA)

    5464-E1GTower

    1xE5-2603v36C1.6GHz15MB1600MHz85W

    M1215+RAID5/50

    8x2.5-inchHS/32

    Open 4/7 Multi-burner

    1x550W

    5464-E2GTower

    1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB M1215+RAID5/50

    6x3.5-inchHS/12

    Open 4/7 Multi-burner

    1x550W

    5464-E3GTower

    1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x8GB M51201GBNobackup

    8x2.5-inchHS/32

    Open 4/7 Multi-burner

    2x550W

    5464-E4GTower

    1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x8GB M51201GBFlash

    8x2.5-inchHS/32

    3x300GB10KSAS

    4/7 Multi-burner

    2x750W

    5464-E5G

    Tower

    1xE5-2640v38C2.6GHz

    20MB1866MHz90W

    1x16GB M51202GB

    Flash

    8x2.5-inch

    HS/32

    Open 4/7 Multi-

    burner

    2x750W

    LatinAmerica&Brazil

    5464-EFxTower

    1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB M51201GBFlash+Cap

    8x2.5-inchHS/32

    Open 4/7 DVD 1x550W

    5464-EGxTower

    1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB M51201GBFlash

    8x2.5-inchHS/32

    Open 4/7 DVD 1x550W

    5464-EHxTower

    1xE5-2650v310C2.3GHz25MB2133MHz105W

    1x16GB M51201GBFlash

    8x2.5-inchHS/32

    Open 4/7 DVD 1x750W

    Japan

    5464-E6JTower

    1xE5-2603v36C1.6GHz15MB1600MHz85W

    1x8GB M51201GBFlash

    8x2.5-inchHS/32

    Open 4/7 DVD 1x550W

    5464-E7JTower

    1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB M51201GBFlash

    8x2.5-inchHS/32

    Open 4/7 DVD 1x550W

  • 8/9/2019 Tips 1242

    11/57

    LenovoSystemx3500M5 11

    Table3.Expressmodels(Part2)

    MTM**

    Form

    factor

    Intel Xeon processors†

      two maximum)

    Memory R AID D rive

    bays

     std / max)

    D rives S lots

     std /

    max)

    O ptical Pow er

    supply

     2 max)

     Australia&NewZealand

    5464-EIMTower 1xE5-2609v36C1.9GHz15MB1600MHz85W 1x8GB M1215+RAID5/50 6x3.5-inchHS/12 Open 4/7 Multi-burner 1x550W

    5464-EJMTower

    1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB M1215+RAID5/50

    8x2.5-inchHS/32

    Open 4/7 Multi-burner

    1x550W

    5464-EKMTower

    1xE5-2620v36C2.4GHz15MB1866MHz85W

    2x8GB M51201GBFlash+Cap

    8x2.5-inchHS/32

    Open 4/7 Multi-burner

    1x550W

    5464-ELMTower

    1xE5-2640v38C2.6GHz20MB1866MHz90W

    2x8GB M51201GBFlash+Cap

    8x2.5-inchHS/32

    Open 4/7 Multi-burner

    1x750W

    **MTM=MachineTypeModel†Processordetail:Processorquantityandmodel,numberofcores,corespeed,L3cache,memoryspeed,TDP.

    Table4.TopSellerModels

    MTM**

    Form

    factor

    Intel Xeon processors†

      two maximum)

    M emory R AID D rive

    bays

     std / max)

    D rives Slots

     std /

    max)

    O ptica l Pow er

    supply

     2 max)

    UnitedStatesandCanada

    5464-NAYTower

    1xE5-2603v36C1.6GHz15MB1600MHz85W

    1x8GB M1215 6x3.5-inchHS/12

    Open 4/7 Open 1x550W

    5464-NBYTower

    1xE5-2609v36C1.9GHz15MB1600MHz85W

    1x8GB M1215 8x2.5-inchHS/32

    Open 4/7 Open 1x550W

    5464-NCYTower

    1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB M1215 8x2.5-inchHS/32

    Open 4/7 Open 1x550W

    5464-NDYTower

    1xE5-2630v38C2.4GHz20MB1866MHz85W

    1x16GB M5120 8x2.5-inchHS/32

    Open 4/7 Open 1x550W

    5464-NEYTower

    1xE5-2630v38C2.4GHz20MB1866MHz85W

    1x16GB M5120 6x3.5-inchHS/12

    Open 4/7 Open 1x550W

    5464-NFYTower

    1xE5-2650v310C2.3GHz25MB2133MHz105W

    1x16GB M5120 8x2.5-inchHS/32

    Open 4/7 Open 1x750W

    Europe,MiddleEast,andAfrica(EMEA)

    5464-K1G 1xE5-2620v36C2.4GHz15MB1866MHz85W

    1x16GB M52102GBFlash

    8x2.5-inchHS/32

    Open 4/7 Multi-burner

    1x550W

  • 8/9/2019 Tips 1242

    12/57

    LenovoSystemx3500M5 12

    Processor options

    Thex3500M5supportstheprocessoroptionsthatarelistedinthefollowingtable.Theserversupportsuptotwoprocessors.Thistableshowswhichservermodelsfeatureeachprocessorasstandard.Ifthereisnocorrespondingwhere-used modelforaparticularprocessor,thisprocessorisavailablethroughCTOonly.

    Table5.Processoroptions

    Part

    number

    Feature

    codes* Description

    Standard models

    where used

    81Y7113 A5C8/A5MP IntelXeonE5-2603v36C1.6GHz15MB1600MHz85W A2x

    81Y7114 A5C9/A5MQ IntelXeonE5-2609v36C1.9GHz15MB1600MHz85W B2x

    81Y7115 A5CA/A5MR IntelXeonE5-2620v36C2.4GHz15MB1866MHz85W C2x,C3x,C4x

    00MU332 ASLW/ASLZ IntelXeonE5-2623v34C3.0GHz10MB1866MHz105W -

    81Y7116 A5CB/A5MS IntelXeonE5-2630v38C2.4GHz20MB1866MHz85W D2x

    00KG052 ARZK/ARZL IntelXeonE5-2630Lv38C1.8GHz20MB1866MHz55W -

    81Y7117 A5CC/A5MT IntelXeonE5-2640v38C2.6GHz20MB1866MHz90W -

    81Y7118 A5CD/A5MU IntelXeonE5-2650v310C2.3GHz25MB2133MHz105W G2x,G3x

    81Y7121 A5CG/A5MX IntelXeonE5-2650Lv312C1.8GHz30MB2133MHz65W -

    00MU330 ASLU/ASLX IntelXeonE5-2660v312C2.3GHz30MB2133MHz105W -

    00MU331 ASLV/ASLY IntelXeonE5-2667v38C3.2GHz20MB2133MHz135W -

    81Y7119 A5CE/A5MV IntelXeonE5-2670v312C2.3GHz30MB2133MHz120W H2x

    81Y7120 A5CF/A5MW IntelXeonE5-2680v312C2.5GHz30MB2133MHz120W J2x

    00KG038 ARYU/ARYX IntelXeonE5-2690v312C2.6GHz30MB2133MHz135W -

    00KG039 ARYV/ARYY IntelXeonE5-2697v314C2.6GHz35MB2133MHz145W -

    00KG040 ARYW/ARYZ IntelXeonE5-2699v318C2.8GHz45MB2133MHz145W -

    *Thefirstfeaturecodeisforthefirstprocessor;thesecondfeaturecodeisforthesecondprocessor.

  • 8/9/2019 Tips 1242

    13/57

    LenovoSystemx3500M5 13

    Mem ory opt ions

    TheSystemx3500M5supportsTruDDR4memory.TruDDRMemoryusesthehighestqualitycomponentsthataresourcedfromTier1DRAMsuppliersandonlymemorythatmeetsourstrictrequirementsisselected.ItiscompatibilitytestedandtunedoneverySystemxservertomaximizeperformanceandreliability.TruDDR4MemoryhasauniquesignatureprogrammedintotheDIMMthat

    enablesSystemxserverstoverifywhethertheinstalledmemoryisqualifiedorsupported.BecauseTruDDR4Memoryisauthenticated,certainextendedmemoryperformancefeaturescanbeenabledtoextendperformanceoverindustrystandards.Fromaserviceandsupportstandpoint,Systemxmemoryautomaticallyassumesthesystem'swarranty,andserviceandsupportprovidedworldwide.

    Thefollowingtableliststheavailablememoryoptionsforthex3500M5server.

    Table6.Memoryoptions

    Partnumber

    Feature

    code

    Description M axim um

    suppor ted

    Standard

    mode ls

    where used

    RDIMMs-2133MHz

    46W0784 A5B6 4GBTruDDR4Memory(1Rx8,1.2V)PC4-17000CL152133MHzLPRDIMM

    24(12perCPU) -

    46W0788 A5B5 8GBTruDDR4Memory(1Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM

    24(12perCPU) A2x,B2x

    46W0792 A5B8 8GBTruDDR4Memory(2Rx8,1.2V)PC4-17000CL152133MHzLPRDIMM

    24(12perCPU)

    46W0796 A5B7 16GBTruDDR4Memory(2Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM

    24(12perCPU) Allothermodels

    LRDIMMs-2133MHz

    46W0800 A5B9 32GBTruDDR4Memory(4Rx4,1.2V)PC417000

    CL152133MHzLPLRDIMM

    24(12perCPU) -

    95Y4812* A5UK 64GBTruDDR4Memory(4Rx4,1.2V)PC4-17000CL152133MHzLPLRDIMM

    24(12perCPU) -

    *Supportfor64GBLRDIMMsisplannedforalaterdate.

    Theserversupportsupto12DIMMswhenoneprocessorisinstalledandupto24DIMMswhentwoprocessorsareinstalled.Eachprocessorhasfourmemorychannels;therearethreeDIMMsperchannel.

    Thefollowingrulesapplywhenthememoryconfigurationisselected:

    TheserversupportsRDIMMsandLRDIMMs.Mixingtypesofmemory(RDIMMsandLRDIMMs)isnotsupported.ThemaximumquantityofDIMMsthatcanbeinstalledintheserverdependsonthenumberofprocessors. AllDIMMsintheserveroperateatthesamespeed,whichisdeterminedasthelowestvalueofthefollowingfactors:

    Memoryspeedthatissupportedbythespecificprocessor.LowestofmaximumoperatingspeedsforselectedmemoryconfigurationthatdependsonquantityofDIMMsperchannel,asshownunder"Maximumoperatingspeed"sectioninthefollowingtable.

  • 8/9/2019 Tips 1242

    14/57

  • 8/9/2019 Tips 1242

    15/57

    LenovoSystemx3500M5 15

    Internal storage

    Theinternaldrivebaysofthex3500M5areshowninthefollowingfigure.

    Figure5.Internaldrivebays

    TheSystemx3500M5serversupportsthefollowinginternalstorageconfigurations:

    Configurationswith2.5-inchhot-swapdrives:

    8x2.5-inchhot-swapdrives(1RAIDadapter)16x2.5-inchhot-swapdrives(1RAIDadapter)16x2.5-inchhot-swapdrives(2RAIDadapters)24x2.5-inchhot-swapdrives(1RAIDadapter)24x2.5-inchhot-swapdrives(2RAIDadapters)32x2.5-inchhot-swapdrives(1RAIDadapter)32x2.5-inchhot-swapdrives(2RAIDadapters)

    Configurationswith3.5-inchhot-swapdrives:

    6x3.5-inchhot-swapharddiskdrives(1RAIDadapter)12x3.5-inchhot-swapharddiskdrives(2RAIDadapters)

    Configurationswith2.5-inchand3.5-inchhot-swapdrives:6x3.5-inchhot-swapharddiskdrives+16x2.5-inchhot-swapdrives(2RAIDadapters)

    Configurationswith3.5-inchsimple-swapdrives:

    6x3.5-inchsimple-swapharddiskdrives(6GbSATAonboardconnectors)6x3.5-inchsimple-swapharddiskdrives(1adapter)

    Note :Aconfigurationof12simple-swapdrivesisnotsupported.

    Thefollowingdrivetypemixingrulesapply:

    Hot-swapSATAHDDsandhot-swapSASHDDscanbeintermixedonthesamebackplane,butcannotbeintermixedinthesameRAIDarray.

    Hot-swapSATAHDDsandhot-swapSASHDDscanbeintermixedwithSSDsonthesamebackplane,butSASnorSATAHDDscanbeconfiguredwithSSDswithinthesameRAIDarray.

  • 8/9/2019 Tips 1242

    16/57

    LenovoSystemx3500M5 16

    Backplanes

    Thefollowingtableliststheavailablebackplanesforthex3500M5.Standardmodelsshipwithone8x2.5-inchhot-swapbackplaneorone6x3.5-inchhot-swapbackplane,aslisted.

    Table8.Internalstoragebackplane(configuretoorder)

    Feature

    code

    Nam e M odels

    where used

    Maximum

    suppor ted

     A5D4 Systemx3500M52.5-inchHotSwapSAS:8x2.5-inchhot-swapdrives

    Connectto1adapter(2ports)or2adapters(1porteach)

    SupportedbyM5210,M1215,orN2215

     Allotherstandardmodels

    2

     A5N5 Systemx3500M52.5-inchHotSwapSAS8-16:8x2.5-inchhot-swapdrives

    IncludesaSASexpander

    ConnectstobackplaneA5D4tosupportupto16drivesperport

    SupportedbyM5210,M1215,orN2215

    - 2

     A5D5 Systemx3500M53.5-inchHotSwapSAS:

    6x3.5-inchhot-swapdrivesSupportedbyM5210,M1215,orN2215

    C3x,C4x 2

     A5UM Systemx3500M53.5-inchSimpleSwap:6x3.5-inchsimple-swapdrives

    ConnectionstoonboardSATAports

    - 1

     A5D2 Systemx3500M53.5-inchSimpleSwap:6x3.5-inchsimple-swapdrives

    ConnectionstoRAIDcontroller

    - 1

  • 8/9/2019 Tips 1242

    17/57

    LenovoSystemx3500M5 17

    Thefollowingtablelisttheavailablehot-swapdrivebayupgrades.

    Table9.Drivebayupgradeoptions

    Option

    part numberNa m e

    00AL540 8x2.5-inchHot-SwapSAS/SATAUpgradeKitfor16or24HDDs:Forexistingconfigurationswith8xor16x2.5-inchbays Adds8x2.5-inchhot-swapdrives

    BackplaneIncludesaSASexpander

    SamebackplaneasfeatureA5N5

    00AL541 8x2.5-inchHot-SwapSAS/SATAUpgradeKitfor32HDDs:Forexistingconfigurationswith24x2.5-inchbays

     Adds8x2.5-inchhot-swapdrives

    SamebackplaneasfeatureA5D4

    00AL542 6x3.5-inchHot-SwapSAS/SATAUpgradeKitfor12HDDs:Forexistingconfigurationswith6x3.5-inchdrives

     Adds6x3.5-inchhot-swapdrives

    SamebackplaneasfeatureA5D5

    00AL543 6x3.5-inchHot-SwapSAS/SATAUpgradeKitfor22HDDs(Intermix):Forexistingconfigurationswith16x2.5-inchdrives

     Adds6x3.5-inchhot-swapdrives

    SamebackplaneasfeatureA5D5

    00AL544 8x2.5-inchHot-SwapSAS/SATAUpgradeKitfor14HDDs(Intermix):Forexistingconfigurationswith6x3.5-inchdrives

     Adds8x2.5-inchhot-swapdrives

    SamebackplaneasfeatureA5D4

    00KG037 8x2.5-inchHot-SwapSAS/SATAUpgradeKitfor22HDDs(Intermix):Forexistingconfigurationswith6x3.5-inchand8x2.5-inchdrives

     Adds8x2.5-inchhot-swapdrives

    SamebackplaneasfeatureA5N5

    00AL539 SAScableoptionforDualRAIDarray(RAIDadapternotincluded):ForconfigurationswithtwoRAIDcards

    Onlyneededwhenupgradingfrom8x2.5-inchdrivesto16,24or32drives,asshowninFigure7.Connectssecondadaptertobackplane

  • 8/9/2019 Tips 1242

    18/57

    LenovoSystemx3500M5 18

    Drive bay configurations

    Thefollowingfigureshowshowmodelswitheight2.5-inchdrivebayscanbeupgradedtoatotalof32drivebays.Insuchconfigurations,alldrivesareconnectedtooneRAIDcontroller.SupportedadaptersaretheServeRAIDM5210,ServeRAIDM1215,andN2215hostbusadapter.

    Figure6.Configurationsof2.5-inchdriveswithoneRAIDadapter

    Thefollowingfigureshowshowmodelswitheight2.5-inchdrivebayscanbeupgradedtoatotalof32drivebaysthatusetwoRAIDcontrollerforaddedperformance.SupportedadaptersaretheServeRAIDM5210,ServeRAIDM1215,andN2215hostbusadapter.

    Figure7.Configurationsof2.5-inchdriveswithtwoRAIDadapters

  • 8/9/2019 Tips 1242

    19/57

    LenovoSystemx3500M5 19

    Thefollowingfigureshowshowmodelswithsix3.5-inchhot-swapdrivebayscanbeupgradedto12drivebays.SuchaconfigurationrequirestwoRAIDcontrollers.SupportedadaptersaretheServeRAIDM5210,ServeRAIDM1215,andN2215hostbusadapter.

    Figure8.Configurationsof3.5-inchdrives

    Forconfigure-to-orderconfigurations,theserveralsosupportssimple-swap3.5-inchdrives.Thesimple-swapdrivescanbeconnectedtothe6GbSATAportsonthesystemboardoftheserverortoaRAIDcontroller.Onlysix3.5-inchdrivesaresupported;aconfigurationof12simple-swapdrivesisnotsupported.

    Figure9.Simple-swap3.5-inchdrives

  • 8/9/2019 Tips 1242

    20/57

    LenovoSystemx3500M5 20

    Theserveralsosupportscombinationsof2.5-inchdrivebays(upto16)and3.5-inchdrivebays(6bays).Theupgradepathfrommodelswith2.5-inchdrivesisshowninthefollowingfigure.The3.5-inchdrivesmustbeconnectedtoaseparateRAIDadapter.

    Figure10.Combinationsof2.5-inchand3.5-inchdrivebaysfroma2.5-inchbase

    Thefollowingfigureshowstheupgradepathfrommodelswith3.5-inchdrives.

    Figure11.Combinationsof2.5-inchand3.5-inchdrivebaysfroma3.5-inchbase

  • 8/9/2019 Tips 1242

    21/57

  • 8/9/2019 Tips 1242

    22/57

    LenovoSystemx3500M5 22

    TheServeRAIDM5210SAS/SATAControllerhasthefollowingspecifications:

    Eightinternal12GbpsSAS/SATAportsUpto12GbpsthroughputperportTwox4HDmini-SASinternalconnectors(SFF-8643)SupportsconnectionstoSAS/SATAHDDsandSSDsandSASExpandersSupportsRAID0,1,and10SupportsRAID5and50withoptionalM5200SeriesRAID5upgradesSupportsRAID6and60withtheoptionalM5200SeriesRAID6upgradeOptionalsupportforself-encryptingdrives(SEDs)withMegaRAIDSafeStore(withRAID5upgrade)Supports1GBnon-backedcacheor1GB,2GBor4GBflash-backedcachePCIe3.0x8hostinterfaceBasedontheLSISAS310812GbpsROCcontroller

    TheN2215SAS/SATAHBAhasthefollowingspecifications:

    Eightinternal12GbpsSAS/SATAportsUpto12GbpsthroughputperportTwox4HDmini-SASinternalconnectors(SFF-8643)SupportsconnectionstoSAS/SATAHDDsandSSDs

    OptimizedforSSDperformanceNoRAIDsupportPCIe3.0x8hostinterfaceBasedontheLSISAS300812Gbpscontroller

    Formoreinformation,seethelistofLenovoPressProductGuidesintheRAIDadapterscategoryatthiswebsite:http://lenovopress.com/systemx/raid

    http://lenovopress.com/systemx/raidhttp://lenovopress.com/systemx/raid

  • 8/9/2019 Tips 1242

    23/57

    LenovoSystemx3500M5 23

    Internal dr ive options

    Thefollowingtablelistsharddriveoptionsforinternaldiskstorageofthex3500M5server.

    Table11.Driveoptionsforinternaldiskstorage(Part1)

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    3.5-inchhot-swapHDDs-12GbpsNLSAS

    00FN188 A5VP 2TB7.2K12GbpsNLSAS3.5-inchG2HS512eHDD 12

    00FN208 A5VQ 4TB7.2K12GbpsNLSAS3.5-inchG2HS512eHDD 12

    00FN228 A5VR 6TB7.2K12GbpsNLSAS3.5-inchG2HS512eHDD 12

    3.5-inchhot-swapSEDs-12GbpsNLSAS

    00FN238 A5VS 2TB7.2K12GbpsNLSAS3.5-inchG2HS512eSED 12

    00FN248 A5VT 4TB7.2K12GbpsNLSAS3.5-inchG2HS512eSED 12

    00FN258 A5VU 6TB7.2K12GbpsNLSAS3.5-inchG2HS512eSED 12

    3.5-inchhot-swapHDDs-12GbpsNLSATA

    81Y9794 A22T 2TB7.2K6GbpsNLSATA3.5-inchG2HSHDD 12

    81Y9798 A22S 3TB7.2K6GbpsNLSATA3.5-inchG2HSHDD 12

    49Y6002 A3W9 4TB7.2K6GbpsNLSATA3.5-inchG2HSHDD 12

    3.5-inchhot-swapHDDs-6GbpsNLSATA

    00FN113 A5VD 2TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12

    00FN128 A5VF 3TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12

    00FN143 A5VH 4TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12

    00FN158 A5VK 5TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12

    00FN173 A5VM 6TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12

    3.5-inchsimple-swapHDDs-6GbpsNLSATA

    00FN118 A5VE 2TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6

    00FN133 A5VG 3TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6

    00FN148 A5VJ 4TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6

    00FN163 A5VL 5TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6

    00FN178 A5VN 6TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6

    81Y9810 A22W 2TB7.2K6GbpsNLSATA3.5-inchG2SSHDD 6

    81Y9814 A22V 3TB7.2K6GbpsNLSATA3.5-inchG2SSHDD 6

    49Y6012 A3WA 4TB7.2K6GbpsNLSATA3.5-inchG2SSHDD 6

  • 8/9/2019 Tips 1242

    24/57

    LenovoSystemx3500M5 24

    Table11.Driveoptionsforinternaldiskstorage(Part2)

    Partnumber

    Feature

    code

    Description M axim um

    suppor ted

    2.5-inchhot-swap15KHDDs-12GbpsSAS

    00AJ081 A4TR 300GB15K6GbpsSAS2.5-inchG3HSHDD 32

    00AJ126 A4TS 600GB15K6GbpsSAS2.5-inchG3HSHDD 32

    00NA221 ASBB 300GB15K12GbpsSAS2.5"G3HS512eHDD 32

    00NA231 ASBD 600GB15K12GbpsSAS2.5"G3HS512eHDD 32

    2.5-inchhot-swap10KHDDs-12GbpsSAS

    00NA241 ASBF 600GB10K12GbpsSAS2.5"G3HS512eHDD 32

    00NA251 ASBH 900GB10K12GbpsSAS2.5"G3HS512eHDD 32

    00NA261 ASBK 1.2TB10K12GbpsSAS2.5"G3HS512eHDD 32

    00NA271 ASBM 1.8TB10K12GbpsSAS2.5"G3HS512eHDD 32

    2.5-inchhot-swap15KHDDs-12GbpsSASself-encyrptingdrive(SED)

    00NA281 ASBP 300GB15K12GbpsSAS2.5"G3HS512eSED 32

    00NA286 ASBQ 600GB15K12GbpsSAS2.5"G3HS512eSED 32

    2.5-inchhot-swap10KHDDs-12GbpsSASSED

    00NA291 ASBR 600GB10K12GbpsSAS2.5"G3HS512eSED 32

    00NA296 ASBS 900GB10K12GbpsSAS2.5"G3HS512eSED 32

    00NA301 ASBT 1.2TB10K12GbpsSAS2.5"G3HS512eSED 32

    00NA306 ASBU 1.8TB10K12GbpsSAS2.5"G3HS512eSED 32

    2.5-inchhot-swap15KHDDs-12GbpsSAS-SSDHybrid

    00NA311 ASBV 300GB15K12GbpsSAS2.5"G3HS512eHybrid 32

    00NA321 ASBX 600GB15K12GbpsSAS2.5"G3HS512eHybrid 32

    2.5-inchhot-swapSSDs-12GbpsSAS-EnterpriseCapacity

    00NA671 ASW6 3.84TB6GbSASEnterpriseCapacityG3HSMLCSSD 32

    2.5-inchhot-swapSSDs-12GbpsSAS-Enterprise

    00FN379 AS7C 200GB12GSAS2.5-inchMLCG3HSEnterpriseSSD 32

    00FN389 AS7E 400GB12GSAS2.5-inchMLCG3HSEnterpriseSSD 32

    00FN399 AS7G 800GB12GSAS2.5-inchMLCG3HSEnterpriseSSD 32

    00FN409 AS7J 1.6TB12GSAS2.5-inchMLCG3HSEnterpriseSSD 32

    2.5-inchhot-swapSSDs-12GbpsSASSED-Enterprise

    00FN419 AS7L 400GBSED12GSAS2.5-inchMLCG3HSEnterpriseSSD 32

    00FN424 AS7M 800GBSED12GSAS2.5-inchMLCG3HSEnterpriseSSD 32

  • 8/9/2019 Tips 1242

    25/57

    LenovoSystemx3500M5 25

    Table11.Driveoptionsforinternaldiskstorage(Part3)

    Partn um b er F ea tu recode

    Description M axim um

    suppor ted

    2.5-inchhot-swap10KHDDs-6GbpsSAS

    00AJ096 A4TL 300GB10K6GbpsSAS2.5-inchG3HSHDD 32

    00AJ091 A4TM 600GB10K6GbpsSAS2.5-inchG3HSHDD 32

    00AJ071 A4TN 900GB10K6GbpsSAS2.5-inchG3HSHDD 32

    00AJ146 A4TP 1.2TB10K6GbpsSAS2.5-inchG3HSHDD 32

    2.5-inchhot-swapHDDs-6GbpsNLSAS

    00AJ086 A4TU 1TB7.2K6GbpsNLSAS2.5-inchG3HSHDD 32

    00AJ121 A4TT 500GB7.2K6GbpsNLSAS2.5-inchG3HSHDD 32

    2.5-inchhot-swapHDDs-6GbpsNLSATA

    00AJ136 A4TW 500GB7.2K6GbpsNLSATA2.5-inchG3HSHDD 32

    00AJ141 A4TX 1TB7.2K6GbpsNLSATA2.5-inchG3HSHDD 32

    2.5-inchhot-swapSSDs-6GbpsSAS-Enterprise

    00AJ217 A4UC 800GBSAS2.5-inchMLCG3HSEnterpriseSSD 32

    2.5-inchhot-swapSSDs-6GbpsSATASSDs-Enterprise

    00AJ161 A4U4 S3700400GBSATA2.5-inchMLCG3HSEnterpriseSSD 32

    2.5-inchhot-swapSSDs-6GbpsSATA-EnterpriseValue

    00AJ405 A579 480GBSATA2.5-inchMLCG3HSEnterpriseValueSSD 32

    2.5-inchhot-swapSSDs-6GbpsSATA-Entry

    00FN347 AS0J 960GBSATA2.5-inchMLCG3HSEntrySSD 32

  • 8/9/2019 Tips 1242

    26/57

    LenovoSystemx3500M5 26

    Internal backup un its

    Theserversupportstheinternalbackupunitoptionsthatarelistedinthefollowingtable.

    Table12.Internaltapedrives

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    Drives

    - A2U7 RDX3InternalUSBDrive 1

    00D2786 A2VE RDXInternalUSB3.0Dockwith320GBCartridge(includesUSBcable) 1

    00D2787 A2VF RDXInternalUSB3.0Dockwith500GBCartridge(includesUSBcable) 1

    00D2788 A2VG RDXInternalUSB3.0Dockwith1TBCartridge(includesUSBcable) 1

    49Y9898 5345 HalfHighLTOGen5InternalSASTapeDrive* 2

    00D8924 A3S3 HalfHighLTOUltriumGen6InternalSASTapeDrive* 2

    Media

    46W6589 A3S6 LTOUltriumGen6SingleMedia(2.6TBnativecapacity)

    46C5367 5708 RDX320GBCartridge

    46C5368 5709 RDX500GBCartridge

    81Y3647 A1VL RDX1TBCartridge

    *SupportedwiththeN2215SAS/SATAHBA;alsorequires12GbSASCableforLTOTapedrive,SBB00MV226,featurecodeASTU

    USBdevicesareattachedtotheinternalUSBconnector.Foroptionpartnumberorders,theUSBcableisincludedwiththeRDXdrive.ForCTO,usefeaturecode9266.

    Formoreinformation,seethelistofProductGuide,RDXUSB3.0DiskBackupSolution ,whichisavailableatthiswebsite:http://lenovopress.com/tips0894

    http://lenovopress.com/tips0894http://lenovopress.com/tips0894

  • 8/9/2019 Tips 1242

    27/57

    LenovoSystemx3500M5 27

    Optical dr ives

    Theserversupportstheopticaldriveoptionsthatarelistedinthefollowingtable.

    Table13.Opticaldrives

    Part num ber Feature

    code

    Description M axim um

    suppor ted

    Standard models

    where used

    None* 4154 Half-HighSATADVD-ROM 2 Allstandardmodels

    81Y6404 4155 Half-HighSATAMultiburner 2 -

    *ThisoptionisavailableviaCTOonlyorisalreadyinstalledinstandardmodels.

    Thetwohalf-highdrivesinthetablecanbeinstalledinanyopen5.25-inchdrivebay.

    TheHalf-HighSATADVD-ROMdrivesupportsthefollowingmediaandspeedsforreading:

    CD-ROM48XCD-DA(DAE)40XCD-R48XCD-RW40XDVD-ROM(singlelayer)16XDVD-ROM(duallayer)12XDVD-R(4.7GB)16XDVD-RDL12XDVD+R16XDVD+RDL12XDVD-RW(4.7GB)12XDVD+RW12XDVD-RAM(4.7/9.4GB)6X

    TheHalf-HighSATAmultiburnerdrivesupportsthesamemediaandspeedsforreadingasHH

    DVD-ROM.Inaddition,thisdrivesupportsthefollowingmediaandspeedsforwriting:CD-R24XCD-RW4XHighSpeedCD-RW10XUltraSpeedCD-RW16XDVD-R8XDVD-RDL8XDVD+R8XDVD+RDL8XDVD-RW6XDVD+RW8XDVD-RAM3X

  • 8/9/2019 Tips 1242

    28/57

    LenovoSystemx3500M5 28

    I /O expansion options

    TheserversupportsuptosevenPCIe3.0slots:Fourslots(1-4)whenoneCPUisinstalledorsevenslotswhentwoCPUsareinstalled.Thefollowingslotformfactorsareavailable:

    Slot1:PCIe3.0x8(x8wired);full-height,half-lengthSlot2:PCIe3.0x16(x8wired);full-height,full-length

    Slot3:PCIe3.0x16(x16wired);full-height,full-lengthSlot4:PCIe3.0x8(x8wired);full-height,full-lengthSlot5:PCIe3.0x8(x8wired);full-height,half-length(requiressecondprocessor)Slot6:PCIe3.0x16(x16wired);full-height,full-length(requiressecondprocessor)Slot7:PCIe3.0x16(x16wired)full-height,full-length(requiressecondprocessor)

    Slots3and6supportdouble-wideGPUs

    TheCOMPortBracket,partnumber00KC332,isusedformakinganexternalserialportavailableattherearoftheserver.Thisoptionincludesthebracketandthecable.TheCOMPortoptionismountedinoneofthePCIeslotsandthatPCIeslotcannotbeused.ThefollowingtableliststhePCIeslotoptions.

    Table14.Systemx3500M5COMPortKitorderinginformation

    Part num ber Feature

    code

    Description M axim um

    suppor ted

    00KC332 ARZ0 Systemx3500M5COMPortKit 1

    Network adapters

    Thex3550M5supportsfourintegratedGigabitEthernetportswiththefollowingfeatures:

     ABroadcomBCM5719chip

    FourGigabitEthernetports

    NICTeaming(loadbalancingandfailover)

    Ethernetfeatures:

    Compliantwith1GbEthernetIEEE802.3,802.3u,and802.3abPHYspecificationsIntegratedPHYfor10/100/1000Mbpsformultispeed,full,andhalf-duplexauto-negotiation AutomaticMDIcrossoverIEEE802.3x-compliantflowcontrolsupportIEEE1588protocoland802.1AStimesynchronizationimplementationIEEE802.3az-EnergyEfficientEthernet(EEE)

    I/OVirtualizationfeatures:

    I/OVirtualizationsupportforVMwareNetQueueandMicrosoftvirtualmachinequeue(VMQ)FunctionLevelReset(FLR)IEEE802.1qVirtualLocalAreaNetwork(VLAN)taggingsupport

    Statelessoffloadandperformancefeatures:

    TCP,IP,andUserDatagramProtocol(UDP)checksumoffloadTCPsegmentationoffload(TCO)LargeSendOffload(LSO)ReceiveSideScaling(RSS)andTransmitSideScaling(TSS)MessageSignalInterrupt(MSI)andMessageSignalInterruptExtension(MSI-X)supportSupportforjumboframesupto9600bytes

  • 8/9/2019 Tips 1242

    29/57

    LenovoSystemx3500M5 29

    Thefollowingtablelistsothersupportednetworkadapters.

    Table15.Networkadapters

    P ar t n um b er F ea tu re

    code

    Description M axim um

    suppor ted

     1 CPU / 2

    CPUs)

    40GbEthernet

    00D9550 A3PN MellanoxConnectX-340GbE/FDRIBVPIAdapter* 4/7

    10GbEthernet

    44T1370 A5GZ BroadcomNetXtreme2x10GbEBaseTAdapter 4/7

    94Y5180 A4Z6 BroadcomNetXtremeDualPort10GbESFP+Adapter* 4/7

    00JY830 A5UU EmulexVFA52x10GbESFP+AdapterandFCoE/iSCSISW* 4/7

    None AS3M EmulexVFA52x10GbESFP+IntegratedAdapter* 1/1

    00JY820 A5UT EmulexVFA52x10GbESFP+PCIeAdapter* 4/700JY824 A5UV EmulexVFA5FCoE/iSCSISWforPCIeAdapterforSystemx(FoD)

    (FeaturesonDemandupgradefor00JY820andfeaturecodeAS3M)4/7

    49Y7960 A2EC IntelX520DualPort10GbESFP+Adapter* 4/7

    49Y7970 A2ED IntelX540-T2DualPort10GBaseTAdapter 4/7

    81Y3520 AS73 IntelX7102x10GbESFP+Adapter* 4/7

    00D9690 A3PM MellanoxConnectX-310GbEAdapter* 4/7

    90Y4600 A3MR QLogic8200DualPort10GbESFP+VFA* 4/7

    00Y5624 A3MT QLogic8200VFAFCoE/iSCSILicenseforSystemx(FoD)(FeaturesonDemandupgradefor90Y4600)

    4/7

    47C9977 A522 SolarflareSFN7122F2x10GbESFP+FlareonUltra* 4/7

    1GbEthernet

    42C1780 2995 BroadcomNetXtreme2xGbEBaseTAdapter 4/7

    90Y9370 A2V4 BroadcomNetXtremeIDualPortGbEAdapter 4/7

    90Y9352 A2V3 BroadcomNetXtremeIQuadPortGbEAdapter 4/7

    49Y4230 5767 IntelEthernetDualPortServerAdapterI340-T2 4/7

    49Y4240 5768 IntelEthernetQuadPortServerAdapterI340-T4 4/7

    00AG510 A56L IntelI350-T22xGbEBaseTAdapter 4/7

    00AG520 A56M IntelI350-T44xGbEBaseTAdapter 4/7

    *RequireSFP+opticaltransceiversorDACcablesthatmustbepurchasedseparately.

    Formoreinformation,seethelistofLenovoPressProductGuidesintheNetworkingadapterscategoryat:http://lenovopress.com/systemx/networkadapters

    http://lenovopress.com/systemx/networkadaptershttp://lenovopress.com/systemx/networkadapters

  • 8/9/2019 Tips 1242

    30/57

    LenovoSystemx3500M5 30

    Storage host bus adapters

    ThefollowingtablelistsstorageHBAsthataresupportedbythex3500M5server.

    Table16.Storageadapters

    Part num ber Feature

    code

    Description M axim um

    suppor ted

     1 CPU / 2 CPUs)

    16GbFibreChannel

    81Y1668 A2XU Brocade16GbFCSingle-portHBAforSystemx 4/7

    81Y1662 A2W6 Emulex16GbFCDual-portHBAforSystemx 4/7

    81Y1655 A2W5 Emulex16GbFCSingle-portHBAforSystemx 4/7

    00Y3341 A3KX QLogic16GbFCDual-portHBAforSystemx 4/7

    00Y3337 A3KW QLogic16GbFCSingle-portHBAforSystemx 4/7

    8GbFibreChannel

    46M6050 3591 Brocade8GbFCDual-portHBAforSystemx 4/7

    46M6049 3589 Brocade8GbFCSingle-portHBAforSystemx 4/7

    42D0494 3581 Emulex8GbFCDual-portHBAforSystemx 4/7

    42D0485 3580 Emulex8GbFCSingle-portHBAforSystemx 4/7

    42D0510 3579 QLogic8GbFCDual-portHBAforSystemx 4/7

    42D0501 3578 QLogic8GbFCSingle-portHBAforSystemx 4/7

    SAS

    46M0907 5982 6GbSASHBAController 4/7

    00AE912 A5M0 N2225SAS/SATAHBAforSystemx 4/7

    00AE916 A5M1 N2226SAS/SATAHBAforSystemx 4/7

    Formoreinformation,seethelistofLenovoPressProductGuidesintheHostbusadapterscategoryatthiswebsite:http://lenovopress.com/systemx/hba

    PCIe SSD adap ters

    TheservercurrentlydoesnotsupportHighIOPSSSDadapters.

    http://lenovopress.com/systemx/hbahttp://lenovopress.com/systemx/hba

  • 8/9/2019 Tips 1242

    31/57

    LenovoSystemx3500M5 31

    GPU adapters

    Thex3500M5serversupportsgraphicsprocessingunits(GPUs)thatarelistedinthefollowingtable.UptotwoGPUsaresupported,dependingonthenumberofprocessorsthatareinstalledinaserver.

    Table17.GPUadapters

    Part num ber Feature code Description M axim um supported

     1 CPU / 2 CPUs)

    00FP672 A3YV NVIDIAQuadroK6000 1/2

    Thefollowingotherrulesapply:

    IftwoGPUsareinstalled,theymustbeidentical

    ThefirstGPUisinstalledinslot3;thesecondGPUisinstalledinslot6andrequiresthesecondprocessortobeinstalled.

    ThenumberofGPUsthatcanbeinstalleddependsonthetypeofpowersupplythatisinstalledandthetypeandnumberofothercomponentsthatareinstalled.Formoreinformation,seethePower

    Supplysection.

    IfaNVIDIAcardisinstalled,themaximummemorythatcanbeinstalledis1TB.

    Powe r suppl ies and redun dant cool ing

    Theserversupportsuptotworedundantpowersupplies.Standardmodelscomewithoneortwopowersupplies(dependingonthemodel).

    Theserveralsocomesstandardwithtwo(formodelswithoneprocessorinstalled)orfour(formodelswithtwoprocessorsinstalled)hot-swapcoolingfans.Formodelswithonlyoneprocessor,anoptionalRedundantCoolingKitprovidesN+1coolingredundancy.Thefollowingtableliststhepowersuppliesand

    redundantcoolingupgradeoptions.

    Table18.Powersupplies

    Part

    number

    Feature code Description M axim um

    suppor ted

    Standard models

    where used

    00AL533 A5MY Systemx550WHighEffiencyPlatinumACPowerSupply

    2 A2x,B2x,C2x,C3x,C4x,D2x

    00AL534 A5MZ Systemx750WHighEfficiencyPlatinumACPowerSupply

    2 G2x,G3x

    00AL536 A5N0 Systemx900WHighEfficencyPlatinumACPowerSupply

    2 H2x,J2x

    00AL535 A5N1 Systemx750WHighEfficiencyTitaniumACPowerSupply

    2 -

    None* A5CH Systemx550WHighEfficencyPlatinumACFixedPowerSupply

    1 -

    00AL537 A5D6 Systemx3500M5RedundantCoolingKit 1 -

    *CTOonly

  • 8/9/2019 Tips 1242

    32/57

  • 8/9/2019 Tips 1242

    33/57

    LenovoSystemx3500M5 33

     ACpowersupplyoptionsshipswithoutalinecord,itmustbepurchasedseparately.Country-specificlinecordsandrackcablescanbeorderedifneeded,aslistedinthefollowingtable.

    Table20.Powercables

    Part num ber Feature code Description

    Rackpowercables

    39Y7932 6263 4.3m,10A/100-250V,C13toIEC320-C14RackPowerCable

    39Y7937 6201 1.5m,10A/100-250V,C13toIEC320-C14RackPowerCable

    39Y7938 6204 IEC309C20toC13rackjumpercable

    Country-specificpowercords

    39Y7917 6212 European10AlineC13toCEE7/7(2.8M)

    39Y7918 6213 Denmark10AlineC13toDK2-5A(2.8M)

    39Y7919 6216 Switzerland10AlineC13toSEV1011(2.8M)

    39Y7920 6218 Israel10AlineC13toSI32(2.8M)

    39Y7921 6217 Italy10AlineC13toCEE7/7(2.8M)

    39Y7922 6214 SouthAfrica10AlineC13toSABS164/1(2.8M)

    39Y7923 6215 UnitedKingdom10AlineC13toBS1363(2.8M)

    39Y7924 6211 Australia/NZ10AlineC13toSAA-ASC112(2.8M)

    39Y7925 6219 Korea7AlineC13toKETI15A/250V(2.8M)

    39Y7927 6269 India6AlineC13toFig68(2.8M)

    39Y7928 6210 China6AlineC13toGB2099.1(2.8M)

    39Y7929 6223 Brazil10AlineC13toNBR6147(2.8M)

    39Y7930 6222 Argentina10AlineC13toIRAM2063(2.8M)

    39Y7931 6207 PowerCable-C13/NEMA5-15P14ft

    00CG265 A53E PowerCordTaiwanACplug10A/250V,2.8M;OPT

    00CG267 A53F PowerCordTaiwanACplug15A/125V;2.8M;OPT

    46M2592 A1RF 10A/250VC13toNEMA6-15P2.8mlinecord

    46M2593 A1RE Japan10A/100VC13toJISC-83032.8mlinecord

  • 8/9/2019 Tips 1242

    34/57

    LenovoSystemx3500M5 34

    Integrated virtualization

    TheserversupportstheVMwarevSphere(ESXi)hypervisorononeortwoSDcardswiththeoptionalSDMediaAdapterforSystemx.Thisadapterisinadedicatedconnectoronthesystemboard,asshowninthefollowingfigure.

    Figure12.SDMediaAdapterwithoneSDCardinstalled

    WhenonlyoneSDcardisinstalledintheadapter,youcancreateupto16volumes,eachofwhichispresentedtoUEFIasabootabledevice.WhentwoSDMediacardsareinserted,volumescanbemirrored(RAID1)acrossbothcards,uptoatotalofeightmirroredvolumes.Theuseofmirroredvolumesimprovessystemavailabilitybecausetheserverremainsoperational,evenifoneSDcardfails.TheRAIDfunctionalityishandledinternallybytheSDMediaAdapter.

    Thefollowingtableshowstheavailableoptions.ThetablealsoindicateswhethertheoptionincludestheSDMediaRAIDAdapterandhowmanySDcardsareincluded.

    Table21.Virtualizationoptions

    Part

    number

    Feature

    code

    Description Inc ludes

    Adapter

    SD

    Cards

    Included

    00ML706 A5TJ SDMediaAdapterforSystemsx(Option00ML706includes2blank32GBSDcards)

    Yes 2*

    00ML700 AS2V Blank32GBSDMediaforSystemx No 2

    None** AS4B RAIDAdapterforSDMediaw/VMwareESXi5.1U2(2SDMedia,RAIDed) Yes 2

    None** ASCG RAIDAdapterforSDMediaw/VMwareESXi5.1U2(1SDMedia) Yes 1

    *Option00ML706includestwo32GBSDcards;however,forCTOorders,featurecodeA5TJdoesnotincludeSDmediaandthe32GBcardsandVMwarevSpherepreloadmustbeselectedseparately.

    **CTOonly.

  • 8/9/2019 Tips 1242

    35/57

    LenovoSystemx3500M5 35

    Systems management

    TheservercontainsIMM2.1,whichprovidesadvancedservice-processorcontrol,monitoring,andanalertingfunction.Ifanenvironmentalconditionexceedsathresholdorifasystemcomponentfails,theIMM2.1lightsLEDstohelpyoudiagnosetheproblem,recordstheerrorintheeventlog,andalertsyoutotheproblem.Optionally,theIMM2.1alsoprovidesavirtualpresencecapabilityforremoteserver

    managementcapabilities.

    TheIMMprovidesremoteservermanagementthroughthefollowingindustry-standardinterfaces:

    IntelligentPlatformManagementInterface(IPMI)Version2.0SimpleNetworkManagementProtocol(SNMP)Version3CommonInformationModel(CIM)Webbrowser

    TheoptionalIntegratedManagementModuleAdvancedUpgradeisrequiredforenablingremotepresenceandblue-screencapturefeatures.Theremotepresencefeatureprovidesthefollowingfunctions:

    Remotelyviewingvideowithgraphicsresolutionsupto1600x1200at75Hzwithupto23bitsperpixelcolors,regardlessofthesystemstateRemotelyaccessingtheserverbyusingthekeyboardandmousefromaremoteclientMappingtheCDorDVDdrive,diskettedrive,andUSBflashdriveonaremoteclient,andmappingISOanddisketteimagefilesasvirtualdrivesthatareavailableforusebytheserverUploadingadisketteimagetotheIMMmemoryandmappingittotheserverasavirtualdrive

    Theblue-screencapturefeaturecapturesthevideodisplaycontentsbeforetheIMMrestartstheserverwhentheIMMdetectsanoperating-systemhangcondition.Asystemadministratorcanusetheblue-screencapturetoassistindeterminingthecauseofthehangcondition.Thefollowingtableliststheremotemanagementoption.

    Table22.Remotemanagementoption

    Part num ber Feature code Description M axim um

    suppor ted

    90Y3901 A1ML IntegratedManagementModuleAdvancedUpgrade 1

     Allstandardmodelsincludebasiclightpathdiagnostics,whichincludesystemLEDsonthefrontoftheserver(seethefollowingfigure)andLEDsnearthemonitoredcomponents(forexample,theDIMMerrorLEDonthesystemboard).TheserveralsooffersanoptionalupgradetosupplyanotherarrayoflightpathdiagnosticLEDsonthefrontofthechassis.

    Thefollowingtableliststheorderinginformationforthelightpathdiagnosticspanelupgradekit.

    Table23.Remotemanagementoption

    Part num ber Feature code Description M axim um

    suppor ted

    00AL566 A5N3 Systemx3500M5LightpathUpgradeKit 1

  • 8/9/2019 Tips 1242

    36/57

    LenovoSystemx3500M5 36

    ThefollowingfigureshowsthemeaningofeachLED.

    Figure13.SystemLEDsandtheoptionallightpathdiagnosticspanel

    Note :ThelightpathdiagnosticspanelupgradekitsuppliesthearrayofLEDsthatismountedinabracketthatisinstalledinsidetheserver,asshowninthefollowingfigure.Thelightpathdiagnosticsindicatorsarestillvisibleonthefrontoftheserver,eveniftheupgradekitisnotinstalled.

    Figure14.Systemx3500M5LightpathUpgradeKit

    IBMSecurityKeyLifecycleManagerforSystemxSEDs-FoD(SKLM-FoD)isanoptionalfeature,whichisavailableinSystemxenvironmentsthatcentralizes,simplifies,andautomatesthedataencryptionkeymanagementprocesstohelpminimizeriskandreduceoperationalcosts.SKLM-FoDoffersasimpleandrobustsolutionforkeystorage,keyserving,andkeylifecyclemanagementforself-encryptingdrives(SEDs)inlocalanddistributedSystemxenvironments.TheFoDupgradecanbeconfiguredwiththeServeRAIDM5210andM1215RAIDcontrollerspairedwithSEDs.ThefollowingtablelistsSKLM-FoDpartnumbers.

  • 8/9/2019 Tips 1242

    37/57

    LenovoSystemx3500M5 37

    Table24.SecurityKeyLifecycleManager-FoDpartnumbers

    Part

    number

    Feature

    code

    Description M axim um

    suppor ted

    UnitedStates,Canada,AsiaPacificandJapan

    00D9998 A5U1 IBMSKLMforSystemxw/SEDs-FoDperInstallw/1YrS&S 1

    00D9999 AS6C IBMSKLMforSystemxw/SEDs-FoDperInstallw/3YrS&S 1

    LatinAmerica,Europe,MiddleEastandAfrica

    00FP648 A5U1 IBMSKLMforSystemxw/SEDs-FoDperInstallw/1YrS&S 1

    00FP649 AS6C IBMSKLMforSystemxw/SEDs-FoDperInstallw/3YrS&S 1

    Supported operating systems

    Theserversupportsthefollowingoperatingsystems:

    MicrosoftWindowsServer2012R2MicrosoftWindowsServer2008R2MicrosoftWindowsServer2012SUSELINUXEnterpriseServer11forAMD64/EM64TSUSELINUXEnterpriseServer11withXenforAMD64/EM64TRedHatEnterpriseLinux6Serverx64EditionRedHatEnterpriseLinux7SUSEEnterpriseLinuxServer(SLES)12SUSELinuxEnterpriseServer12withXENVMwarevSphere5.5(ESXi)VMwarevSphere5.1(ESXi)

    Someoperatingsystemsmighthavesupportdelayeduntil60or90daysaftergeneralavailability.For

    moreinformationaboutthesupportedspecificversionsandservicelevelsandanyotherprerequisites.seethefollowingServerProven®website:http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

    Physical and electrical specifications

    Theserverfeaturesthefollowingdimensionsandweight(approximate):

    Tower:

    Width:218mm(8.6in)Depth:720mm(28.3in)

    Height:440mm(17.25in)

    Weightfullyconfigured:45.5kg(100.3lb)Weightminimumconfiguration:30.8kg(67.9lb)

    Withrackconversionkit:

    Width:423mm(16.6in)Depth:706mm(27.8in)Height:218mm(8.6in)Weightfullyconfigured:44.2kg(97.4lb)Weightminimumconfiguration:29.5kg(65lb)minimumconfiguration

    http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtmlhttp://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml

  • 8/9/2019 Tips 1242

    38/57

    LenovoSystemx3500M5 38

    Theserverfeaturesthefollowingsupportedenvironment:

    DesigntoASHRAEClassA3,ambientof36°Cto40°C(96.8°Fto104°F),withrelaxedsupport:

    Supportscloud-likeworkloadwithnoperformancedegradationacceptable(Turbo-Off).Undernocircumstancecananycombinationofworst-caseworkloadandconfigurationresultin

    systemshutdownordesignexposureat40°C.Theworst-caseworkload(likeLinpack,Turbo-On)mighthaveperformancedegradation.

     Airtemperature:

    Serveron:5-40°C(41to104°F);altitude:0-950m(3,100ft)Serveron:5-28°C(41-82°F);altitude:915m(3,000ft)-3050m(10,000ft)Serveroff(withstandbypower):5-45°C(41-113°F)Storage:1-60°C(34-140°F)Shipping:-40-60°C(-40-140°F)

    Humidity:8-85%,Max.DewPoint24°C

    Electrical:

    Modelswith900WACpowersupplies:

    100-127(nominal)Vac;50Hzor60Hz;10.3A200-240(nominal)Vac;50Hzor60Hz;5.0AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.15kVAMaximumconfiguration:1.194kVA

    Modelswith750WPlatinumACpowersupplies:

    100-127(nominal)Vac;50Hzor60Hz;8.6A200-240(nominal)Vac;50Hzor60Hz;4.2AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.15kVAMaximumconfiguration:1.015kVA

    Modelswith750WTitaniumACpowersupplies:

    200-240(nominal)Vac;50Hzor60Hz;4.2AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.15kVAMaximumconfiguration:0.965kVA

    Modelswith550WACpowersupplies:

    100to127(nominal)Vac;50Hzor60Hz;6.5A200to240(nominal)Vac;50Hzor60Hz;3.3AInputkilovolt-amperes(kVA)(approximately):

    Minimumconfiguration:0.16kVAMaximumconfiguration:0.732kVA

    BTUoutput:

    Baseconfiguration:2931Btu/hr(859watts)Maximumconfiguration:4043Btu/hr(1185watts)

     Acousticalnoiseemissions:

    Soundpower,idling:6.0belsSoundpower,operating:6.0bels

  • 8/9/2019 Tips 1242

    39/57

    LenovoSystemx3500M5 39

    Warranty options

    TheLenovoSystemx3500M5hasathree-yearwarrantywith24x7standardcallcentersupportand9x5NextBusinessDayonsitecoverage.AlsoavailableareLenovoServiceswarrantymaintenanceupgradesandpost-warrantymaintenanceagreements,withawell-definedscopeofservices,includingservicehours,responsetime,termofservice,andserviceagreementtermsandconditions.

    Lenovowarrantyserviceupgradeofferingsarecountry-specific.Notallwarrantyserviceupgradesareavailableineverycountry.FormoreinformationaboutLenovowarrantyserviceupgradeofferingsthatareavailableinyourcountry,visittheLenovoServiceswebsite:

    https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do

    Thefollowingtableexplainswarrantyservicedefinitionsinmoredetail.

    Table25.Warrantyservicedefinitions

    Term Description

    On-site

    service

     Aservicetechnicianwillarriveattheclient’slocationforequipmentservice.

    24x7x2hour Aservicetechnicianisscheduledtoarriveattheclient’slocationwithintwohoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservicearoundtheclock,everyday,includingLenovoholidays.

    24x7x4hour Aservicetechnicianisscheduledtoarriveattheclient’slocationwithinfourhoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservicearoundtheclock,everyday,includingLenovoholidays.

    9x5x4hour Aservicetechnicianisscheduledtoarriveattheclient’slocationwithinfourbusinesshoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservice8:00am-5:00pmintheclient'slocaltimezone,Monday-Friday,excludingLenovoholidays.Forexample,ifacustomerreportsanincidentat3:00pmonFriday,thetechnicianwillarriveby10:00amthefollowingMonday.

    9x5nextbusinessday

     Aservicetechnicianisscheduledtoarriveattheclient’slocationonthebusinessdayafterremoteproblemdeterminationiscompleted.Lenovoprovidesservice8:00am-5:00pmintheclient'slocaltimezone,Monday-Friday,excludingLenovoholidays.Callsreceivedafter4:00pmlocaltimerequireanextrabusinessdayforservicedispatch.Nextbusinessdayserviceisnotguaranteed.

    CommittedRepair

    Problemsreceivepriorityhandlingsothatrepairsarecompletedwithinthecommittedtimeof6,8,or24hours.Lenovoprovidesservice24hours/day,everyday,includingLenovoholidays.

    The following Lenovo warranty service upgrades are available:

    Warranty and maintenance service upgrades:

    Three, four, or five years of 9x5 or 24x7 service coverage

    Onsite response from next business day to 2 or 4 hoursCommitted repair serviceWarranty extension of up to 5 yearsPost warranty extensions

    https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.dohttps://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do

  • 8/9/2019 Tips 1242

    40/57

    LenovoSystemx3500M5 40

    Committed Repair Service

    Committed Repair Services enhances the level of Warranty Service Upgrade or PostWarranty/Maintenance Service offering associated with the selected systems. Offerings vary and areavailable in select countries.

    Priority handling to meet defined time frames to restore the failing machine to good workingcondition

    Committed repair service levels are measured within the following coverage hours:

    24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours24x7x8: Service performed 24 hours per day, 7 days per week, within 8 hours24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours

    Hard Drive Retention

    Lenovo’s Hard Drive Retention service is a multi-drive hard drive retention offering that ensures yourdata is always under your control, regardless of the number of hard drives that are installed in yourLenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drivewhile Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.The Hard Drive Retention service can be purchased in convenient bundles with our warrantyupgrades and extensions.

    Microcode Support

    Keeping microcode current helps prevent hardware failures and security exposure. There are twolevels of service: analysis of the installed base and analysis and update where required. Offeringsvary by country and can be bundled with other warranty upgrades and extensions.

    Remote Technical Support Services (RTS)

    RTS provides comprehensive technical call center support for covered servers, storage, operatingsystems, and applications. Providing a single source for support of hardware and software issues,RTS can reduce problem resolution time, decreasing the cost to address technical problems andincreasing uptime. Offerings are available for Windows, Linux, IBM Systems Director, VMware,Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storagedevices.

  • 8/9/2019 Tips 1242

    41/57

    LenovoSystemx3500M5 41

    Regulatory compliance

    Theserverconformstothefollowingstandards:

    FCC-VerifiedtocomplywithPart15oftheFCCRules,ClassACanadaICES-003,issue5,ClassA

    UL/IEC60950-1

    CSAC22.2No.60950-1-07NOM-019 ArgentinaIEC60950-1JapanVCCI,ClassAIEC-60950-1(CBCertificateandCBTestReport) Australia/NewZealandAS/NZSCISPR22:2006,ClassA;AS/NZS60950.1TaiwanBSMICNS13438,ClassA;CNS14336-1GB9254ClassA,GB17625.1ChinaCCCGB4943.1KoreaKN22,ClassA;KN24

    External disk storage expansion

    Theserversupportsattachmenttoexternalstorageexpansionenclosures,suchastheEXP2500series,byusingtheServeRAIDM5225SAS/SATAController.TheservercanalsobeattachedtosupportedexternalstoragesystemsbyusingasupportedHBA.Formoreinformation,seethefollowingtable.

    Table26.RAIDcontrollersandoptionsforexternaldiskstorageexpansion

    Partnumber

    Feature

    code

    Descript ion M axim um

    suppor ted

    Standard models

    where used

    12GbRAIDcontrollers

    00AE938 A5ND ServeRAIDM5225-2GBSAS/SATAController 4 -

    FeatureonDemand(FoD)upgradesfortheM5225

    47C8706 A3Z5 ServeRAIDM5200SeriesRAID6Upgrade 1* -

    47C8710 A3Z7 ServeRAIDM5200SeriesPerformance Accelerator

    1* -

    47C8712 A3Z8 ServeRAIDM5200SeriesSSDCachingEnabler 1* -

    *OneFoDupgradefortheM5225activatesthefeatureonallM5225controllersthatareinstalledinaserver.

    TheServeRAIDM5225SAS/SATAControllerhasthefollowingspecifications:

    Eightexternal12GbpsSAS/SATAportsSupports12,6,and3Gb/sSASand6and3Gb/sSATAdatatransferratesTwoexternalx4mini-SASHDconnectors(SFF-8644)

    Supports2GBflash-backedcache(standard)SupportsRAIDlevels0,1,5,10,and50(standard)SupportsRAID6and60withtheoptionalM5200SeriesRAID6UpgradeSupportsoptionalM5200SeriesPerformanceAcceleratorandSSDCachingupgradesPCIex8Gen3hostinterfaceBasedontheLSISAS310812GbpsROCcontrollerSupportsconnectivitytotheEXP2512andEXP2524storageexpansionenclosures

    FormoreinformationabouttheServeRAIDM5225,seetheLenovoPressProductGuideathttp://lenovopress.com/tips1258

    http://lenovopress.com/tips1258http://lenovopress.com/tips1258

  • 8/9/2019 Tips 1242

    42/57

    LenovoSystemx3500M5 42

    TheServeRAIDM5225SAS/SATAControllersupportsconnectivitytoexternalexpansionenclosuresthatarelistedinthefollowingtable.Uptonineexpansionenclosurescanbedaisy-chainedperoneM5225externalport.Forbetterperformance,distributeexpansionenclosuresevenlyacrossbothM5225ports.

    Table27.Externalexpansionenclosures

    Partnum ber Description M axim um quantity supported per one M 5225

    70F0/70F1 LenovoThinkServerSA120 8

    610012X EXP2512StorageEnclosure 17

    610024X EXP2524StorageEnclosure 9

    Lenovo ThinkServer SA120 support

    FordetailsaboutsupporteddrivesandcablesfortheLenovoThinkServerSA120,seetheLenovoPressProductGuide:http://lenovopress.com/tips1234

    EXP2512 and E XP2524 suppor t

    TheexternalSAScablesthatarelistedinthefollowingtablesupportconnectivitybetweenexternalexpansionenclosuresandtheServeRAIDM5225SAS/SATAController.

    Table28.ExternalSAScablesforexternalstorageexpansionenclosures

    Partnum ber Descript ion M axim um quantity supported per one enclosure

    ServertoExpansionenclosureconnectivity(Mini-SASHDx4toMini-SASx4)

    00MJ162 0.6mSASCable(mSASHDtomSAS) 1

    00MJ163 1.5mSASCable(mSASHDtomSAS) 1

    00MJ166 3mSASCable(mSASHDtomSAS) 1

    ExpansionenclosuretoExpansionenclosureconnectivity(Mini-SASx4toMini-SASx4)

    39R6529 1mSASCable 1

    39R6531 3mSASCable 1

    http://lenovopress.com/tips1234http://lenovopress.com/tips1234

  • 8/9/2019 Tips 1242

    43/57

    LenovoSystemx3500M5 43

    ThefollowingtablelistsdrivesthataresupportedbyEXP2512externalexpansionenclosures.

    Table29.DriveoptionsforEXP2512externalexpansionenclosures

    Partnum ber Descript ion M axim um quantity supportedper one enclosure

    3.5-inchNLSASHSHDDs

    00NC555 2TB7,200rpm6GbSASNL3.5-inchHDD 12

    00NC557 3TB7,200rpm6GbSASNL3.5-inchHDD 12

    00NC559 4TB7,200rpm6GbSASNL3.5-inchHDD 12

    ThefollowingtablelistsHDDsthataresupportedbyEXP2524externalexpansionenclosures.

    Table30.DriveoptionsforEXP2524externalexpansionenclosures

    Partnum ber Description M axim um quant ity supportedper one enclosure

    2.5-inchNLSASHSHDDs

    00NC571 1TB7,200rpm6GbSASNL2.5-inchHDD 24

    2.5-inchSASHSHDDs

    00NC561 146GB15,000rpm6GbSAS2.5-inchHDD 24

    00NC563 300GB15,000rpm6GbSAS2.5-inchHDD 24

    00NC565 600GB10,000rpm6GbSAS2.5-inchHDD 24

    00NC567 900GB10,000rpm6GbSAS2.5-inchHDD 24

    00NC569 1.2TB10,000rpm6GbSAS2.5-inchHDD 24

    2.5-inchSASHSSSDs

    00NC573 200GB6GbSAS2.5-inchSSD 24

    00NC575 400GB6GbSAS2.5-inchSSD 24

  • 8/9/2019 Tips 1242

    44/57

    LenovoSystemx3500M5 44

    External disk storage system s

    ThefollowingtableliststheexternalstoragesystemsthataresupportedbytheserverandcanbeorderedthroughtheSystemxsaleschannel.

    Table31.Externaldiskstoragesystems

    Part num ber Description

    2071CU2 IBMStorwizeV3500LFFDualControlEnclosure

    2071CU3 IBMStorwizeV3500SFFDualControlEnclosure

    6099L2C IBMStorwizeV37003.5-inchStorageControllerUnit

    6099S2C IBMStorwizeV37002.5-inchStorageControllerUnit

    6099T2C IBMStorwizeV37002.5-inchDCStorageControllerUnit

    6194L2C IBMStorwizeV5000LFFControlEnclosure

    6194LEU IBMStorwizeV5000LFFExpansionEnclosure

    6194S2C IBMStorwizeV5000SFFControlEnclosure

    6194SEU IBMStorwizeV5000SFFExpansionEnclosure

    6195SC5 IBMStorwizeV70002.5-inchStorageControllerUnit

    6195LEF IBMStorwizeV70003.5-inchStorageExpansionUnit

    6195SEF IBMStorwizeV70002.5-inchStorageExpansionUnit

    Formoreinformation,seethelistofProductGuidesintheSystemStoragecategoryatthiswebsite:http://lenovopress.com/systemx/externalstorage

    http://lenovopress.com/systemx/externalstoragehttp://lenovopress.com/systemx/externalstorage

  • 8/9/2019 Tips 1242

    45/57

    LenovoSystemx3500M5 45

    External backup units

    Theserversupportstheexternalbackupattachmentoptionsthatarelistedinthefollowingtable.

    Table32.Externalbackupoptions

    Part num ber Description

    Externaltapeexpansionenclosuresforinternaltapedrives

    87651UX 1UTapeDriveEnclosure

    87651NX 1UTapeDriveEnclosure(withNema5-15PLineCord)

    Tapeenclosureadapters(withcables)

    44E8869 USBEnclosureAdapterKit

    40K2599 SASEnclosureAdapterKit

    Internalbackupdrivessupportedbyexternaltapeenclosures

    00D2786 RDXInternalUSB3.0Dockwith320GBCartridge

    00D2787 RDXInternalUSB3.0Dockwith500GBCartridge

    00D2788 RDXInternalUSB3.0Dockwith1TBCartridge

    49Y9898 HalfHighLTOGen5InternalSASTapeDrive

    00D8924 HalfHighLTOUltriumGen6InternalSASTapeDrive

    Externalbackupunits*

    362532Y RDXExternalUSB3.0Dockwith320GBCartridge

    362550Y RDXExternalUSB3.0Dockwith500GBCartridge

    36251TY RDXExternalUSB3.0Dockwith1TBCartridge

    3628L5X HalfHighLTOGen5ExternalSASTapeDrive(withUSlinecord)

    3628N5X HalfHighLTOGen5ExternalSASTapeDrive(withoutl inecord)

    *TheseexternaltapedrivescanbeorderedthroughtheSystemxsaleschannel.Theservermightsupportothertapedrivesthatarenotlistedinthistable.Formoreinformation,seetheIBMSystemStorageInteroperationCenter(SSIC)atthiswebsite:

    http://www.ibm.com/systems/support/storage/ssic 

    Formoreinformation,seethelistofLenovoPressProductGuidesintheBackupunitscategoryatthiswebsite:http://lenovopress.com/systemx/tape

    http://www.ibm.com/systems/support/storage/ssichttp://lenovopress.com/systemx/tapehttp://lenovopress.com/systemx/tapehttp://www.ibm.com/systems/support/storage/ssic

  • 8/9/2019 Tips 1242

    46/57

    LenovoSystemx3500M5 46

    Top-o f-rack Ethernet switches

    Theserversupportsthetop-of-rackEthernetswitchesthatarelistedinthefollowingtable.

    Table33.Top-of-rackswitches

    Part num ber Descript ion

    1Gbtop-of-rackswitches

    7159BAX LenovoRackSwitchG7028(ReartoFront)

    7159CAX LenovoRackSwitchG7052(ReartoFront)

    715952F LenovoRackSwitchG8052(FronttoRear)

    7159G52 LenovoRackSwitchG8052(ReartoFront)

    10Gbtop-of-rackswitches

    7159BF7 LenovoRackSwitchG8124E(FronttoRear)

    7159BR6 LenovoRackSwitchG8124E(ReartoFront)

    715964F LenovoRackSwitchG8264(FronttoRear)

    7159G64 LenovoRackSwitchG8264(ReartoFront)

    7159DFX LenovoRackSwitchG8264CS(FronttoRear)

    7159DRX LenovoRackSwitchG8264CS(ReartoFront)

    7159CFV LenovoRackSwitchG8272(FronttoRear)

    7159CRW LenovoRackSwitchG8272(ReartoFront)

    7159GR5 LenovoRackSwitchG8296(FronttoRear)

    7159GR6 LenovoRackSwitchG8296(ReartoFront)

    40Gbtop-of-rackswitches

    7159BFX LenovoRackSwitchG8332(FronttoRear)

    7159BRX LenovoRackSwitchG8332(ReartoFront)

    Formoreinformation,seethelistofLenovoPressProductGuidesintheTop-of-rackswitchescategoryatthiswebsite:http://lenovopress.com/systemx/tor

    http://lenovopress.com/systemx/torhttp://lenovopress.com/systemx/tor

  • 8/9/2019 Tips 1242

    47/57

    LenovoSystemx3500M5 47

    Uninterruptible po wer sup ply units

    Theserversupportsattachmentstotheuninterruptiblepowersupply(UPS)unitsthatarelistedinthefollowingtable.

    Table34.Uninterruptiblepowersupplyunits(Part1)

    Part num ber Description

    TowerUPSunits

    55951AX T1kVATowerUPS(100-125VAC)

    55951KX T1kVATowerUPS(200-240VAC)

    55952AX T1.5kVATowerUPS(100-125VAC)

    55952KX T1.5kVATowerUPS(200-240VAC)

    53961AX 1000VALCDTowerUPS(120V)

    53961JX 1000VALCDTowerUPS(100V)

    53961KX 1000VALCDTowerUPS(230V)

    53962AX 1500VALCDTowerUPS(120V)

    53962JX 1500VALCDTowerUPS(100V)

    53962KX 1500VALCDTowerUPS(230V)

    Rack-mountedortowerUPSunits

    55941AX RT1.5kVA2URackorTowerUPS(100-125VAC)

    55941KX RT1.5kVA2URackorTowerUPS(200-240VAC)

    55942AX RT2.2kVA2URackorTowerUPS(100-125VAC)

    55942KX RT2.2kVA2URackorTowerUPS(200-240VAC)

    55943AX RT3kVA2URackorTowerUPS(100-125VAC)

    55943KX RT3kVA2URackorTowerUPS(200-240VAC)

    55945KX RT5kVA3URackorTowerUPS(200-240VAC)

    55946KX RT6kVA3URackorTowerUPS(200-240VAC)

    55948KX RT8kVA6URackorTowerUPS(200-240VAC)

    55949KX RT11kVA6URackorTowerUPS(200-240VAC)

    55948PX RT8kVA6U3:1PhaseRackorTowerUPS(380-415VAC)

    55949PX RT11kVA6U3:1PhaseRackorTowerUPS(380-415VAC)

  • 8/9/2019 Tips 1242

    48/57

    LenovoSystemx3500M5 48

    Table34.Uninterruptiblepowersupplyunits(Part2)

    Part num ber Description

    Rack-mountedUPSunits

    53951AX 1500VALCD2URackUPS(100V/120V)

    53951KX 1500VALCD2URackUPS(230V)

    53952AX 2200VALCD2URackUPS(100V/120V)

    53952KX 2200VALCD2URackUPS(230V)

    53953AX 3000VALCD3URackUPS(100V/120V)

    53953JX 3000VALCD3URackUPS(200V/208V)

    53956AX 6000VALCD4URackUPS(200V/208V)

    53956KX 6000VALCD4URackUPS(230V)

    53959KX 11000VALCD5URackUPS(200V/208V/230V)

    24195KX UPS5000

    21303RX UPS7500XHV

    21304RX UPS10000XHV

    Formoreinformation,seethelistofLenovoPressProductGuidesinthePowerinfrastructurecategoryatthiswebsite:http://lenovopress.com/systemx/power

    http://lenovopress.com/systemx/powerhttp://lenovopress.com/systemx/power

  • 8/9/2019 Tips 1242

    49/57

    LenovoSystemx3500M5 49

    Powe r distr ibution un its

    Theserversupportsattachmentstothepowerdistributionunits(PDUs)arelistedinthefollowingtable.

    Table35.Powerdistributionunits(Part1)

    Part num ber Description

    SwitchedandMonitoredPDUs

    46M4002 1U9C19/3C13ActiveEnergyManagerDPIPDU

    46M4003 1U9C19/3C13ActiveEnergyManager60A3PhasePDU

    46M4004 1U12C13ActiveEnergyManagerDPIPDU

    46M4005 1U12C13ActiveEnergyManager60A3PhasePDU

    46M4167 1U9C19/3C13SwitchedandMonitored30A3PhasePDU

    46M4116 0U24C13SwitchedandMonitored30APDU

    46M4119 0U24C13SwitchedandMonitored32APDU

    46M4134 0U12C19/12C13SwitchedandMonitored50A3PhasePDU

    46M4137 0U12C19/12C13SwitchedandMonitored32A3PhasePDU

    EnterprisePDUs

    71762MX UltraDensityEnterprisePDUC19PDU+(WW)

    71762NX UltraDensityEnterprisePDUC19PDU(WW)

    71763MU UltraDensityEnterprisePDUC193Phase60APDU+(NA)

    71763NU UltraDensityEnterprisePDUC193Phase60APDU(NA)

    39M2816 DPIC13EnterprisePDUwithoutl inecord

    39Y8923 DPI60AThreePhaseC19EnterprisePDUwithIEC3093P+G(208V)fixedlinecord

    39Y8941 DPISinglePhaseC13EnterprisePDUwithoutlinecord

    39Y8948 DPISinglePhaseC19EnterprisePDUwithoutlinecord

    Front-endPDUs

    39Y8934 DPI32amp/250VFront-endPDUwithIEC3092P+Gndconnector

    39Y8935 DPI63amp/250VFront-endPDUwithIEC3092P+Gndconnector

    39Y8938 30amp/125VFront-endPDUwithNEMAL5-30Pconnector

    39Y8939 30amp/250VFront-endPDUwithNEMAL6-30Pconnector

    39Y8940 60amp/250VFront-endPDUwithIEC30960A2P+N+Gndconnector

  • 8/9/2019 Tips 1242

    50/57

    LenovoSystemx3500M5 50

    Table35.Powerdistributionunits(Part2)

    Part num ber Descript ion

    UniversalPDUs

    39Y8951 DPIUniversalRackPDUwithUSLVandHVlinecords

    39Y8952 DPIUniversalRackPDUwithCEE7-VIIEuropeLC

    39Y8953 DPIUniversalRackPDUwithDenmarkLC

    39Y8954 DPIUniversalRackPDUwithIsraelLC

    39Y8955 DPIUniversalRackPDUwithItalyLC

    39Y8956 DPIUniversalRackPDUwithSouthAfricaLC

    39Y8957 DPIUniversalRackPDUwithUKLC

    39Y8958 DPIUniversalRackPDUwithAS/NZLC

    39Y8959 DPIUniversalRackPDUwithChinaLC

    39Y8962 DPIUniversalRackPDU(Argentina)

    39Y8960 DPIUniversalRackPDU(Brazil)

    39Y8961 DPIUniversalRackPDU(India)

    0UBasicPDUs

    46M4122 0U24C1316A3PhasePDU

    46M4125 0U24C1330A3PhasePDU

    46M4128 0U24C1330APDU

    46M4131 0U24C1332APDU

    46M4140 0U12C19/12C1360A3PhasePDU

    46M4143 0U12C19/12C1332A3PhasePDU

    Formoreinformation,seethelistofLenovoPressProductGuidesinthePowerinfrastructurecategoryatthiswebsite:http://lenovopress.com/systemx/power

    http://lenovopress.com/systemx/powerhttp://lenovopress.com/systemx/power

  • 8/9/2019 Tips 1242

    51/57

    LenovoSystemx3500M5 51

    Rack options

    Thex3500M5servercanbeinstalledintherackwiththeTowertoRackConversionKit(00AL538).Theresultingserverisa5Urack-mountableserver,asshowninthefollowingfigure.

    Figure15.Thex3500M5withthe5UTowertoRackConversionKit(includedslidekitshown)

    TheTowertoRackConversionKit(00AL538)includesacablemanagementarm;however,standardrackmodels(forexample,5464-C3xandG3x)donotincludeacablemanagementarm.Thefore,thearmmustbeorderedseparatelybyusingpartnumber00KC334.

  • 8/9/2019 Tips 1242

    52/57

    LenovoSystemx3500M5 52

    Thetower-to-rackconversionkit,supportedcablemanagementarmkit,rackconsoleswitches,monitorkits,andmanagementgatewaysarelistedinthefollowingtable.

    Table36.Rackoptions

    Part num ber Feature code Description

    Rackoptionsforthex3500M5

    00KC334 ARZ2 Systemx3500M5CableManagementKit

    00AL538 A5N4 Systemx3500M5TowertoRackConversionKit

    Monitorkitsandkeyboardtrays

    17238BX 1723HC1fcA3EK 1U18.5"StandardConsole

    17238EX 1723HC1fcA3EL 1U18.5"EnhancedMediaConsole

    Consoleswitches

    1754D2X 1754HC2fc6695 Global4x2x32ConsoleManager(GCM32)

    1754D1X 1754HC1fc6694 Global2x2x16ConsoleManager(GCM16)

    1754A2X 1754HC4fc0726 Local2x16ConsoleManager(LCM16)

    1754A1X 1754HC3fc0725 Local1x8ConsoleManager(LCM8)

    Consolecables

    43V6147 3757 SingleCableUSBConversionOption(UCO)

    39M2895 3756 USBConversionOption(4PackUCO)

    46M5383 5341 VirtualMediaConversionOptionGen2(VCO2)

    46M5382 5340 SerialConversionOption(SCO)

    Universalmanagementgatewayandcables

    3858D3X 3858HC1fcA4X1 AvocentUniversalManagementGateway6000

    00AK142 A4X4 UMKVMModuleVGA+SDDualRJ45

    Formoreinformation,seethelistofLenovoPressProductGuidesintheRackcabinetsandoptionscategoryatthiswebsite:http://lenovopress.com/systemx/rack

    http://lenovopress.com/systemx/rackhttp://lenovopress.com/systemx/rack

  • 8/9/2019 Tips 1242

    53/57

  • 8/9/2019 Tips 1242

    54/57

    LenovoSystemx3500M5 54

    Lenovo Financial Services

    LenovoFinancialServicesreinforcesLenovo’scommitmenttodeliverpioneeringproductsandservicesthatarerecognizedfortheirquality,excellence,andtrustworthiness.LenovoFinancialServicesoffersfinancingsolutionsandservicesthatcomplementyourtechnologysolutionanywhereintheworld.

    Wearededicatedtodeliveringapositivefinanceexperienceforcustomerslikeyouwhowanttomaximizeyourpurchasepowerbyobtainingthetechnologyyouneedtoday,protectagainsttechnologyobsolescence,andpreserveyourcapitalforotheruses.

    Weworkwithbusinesses,non-profitorganizations,governmentsandeducationalinstitutionstofinancetheirentiretechnologysolution.Wefocusonmakingiteasytodobusinesswithus.Ourhighlyexperiencedteamoffinanceprofessionalsoperatesinaworkculturethatemphasizestheimportanceofprovidingoutstandingcustomerservice.Oursystems,processesandflexiblepoliciessupportourgoalofprovidingcustomerswithapositiveexperience.

    Wefinanceyourentiresolution.Unlikeothers,weallowyoutobundleeverythingyouneedfromhardwareandsoftwaretoservicecontracts,installationcosts,trainingfees,andsalestax.Ifyoudecideweeksormonthslatertoaddtoyoursolution,wecanconsolidateeverythingintoasingleinvoice.

    OurPremierClientservicesprovidelargeaccountswithspecialhandlingservicestoensurethesecomplextransactionsareservicedproperly.Asapremierclient,youhaveadedicatedfinancespecialistwhomanagesyouraccountthroughitslife,fromfirstinvoicethroughassetreturnorpurchase.Thisspecialistdevelopsanin-depthunderstandingofyourinvoiceandpaymentrequirements.Foryou,thisdedicationprovidesahigh-quality,easy,andpositivefinancingexperience.

    ForyourregionspecificofferspleaseaskyourLenovosalesrepresentativeoryourtechnologyproviderabouttheuseofLenovoFinancialServices.Formoreinformation,seethefollowingLenovowebsite:http://www.lenovo.com/services_warranty/us/en/financial_services.html

    http://www.lenovo.com/services_warranty/us/en/financial_services.htmlhttp://www.lenovo.com/services_warranty/us/en/financial_services.html

  • 8/9/2019 Tips 1242

    55/57

    LenovoSystemx3500M5 55

    Related p ubl ications a nd l inks

    Formoreinformation,seethefollowingresources:

    LenovoSystemx3500M5productpage:http://ibm.com/systems/x/hardware/tower/x3500m5/

    InstallationandServiceGuide:http://ibm.com/support/entry/portal/docdisplay?lndocid=migr-5096811

    ServerProvenhardwarecompatibilitypageforthex3500M5:http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/5464.html

    LenovoPressProductGuidesforSystemxserversandoptions:http://lenovopress.com/systemx

    SystemxConfigurationandOptionsGuide :http://www.ibm.com/systems/xbc/cog/

    xREF:SystemxReference :http://lenovopress.com/xref 

    SystemxSupportPortal:http://ibm.com/support/entry/portal/http://ibm.com/support/entry/portal/Downloads/Hardware/Systems/System_x/System_x3500_M5

    IBMSystemStorageInteroperationCenter(SSIC):http://www.ibm.com/systems/support/storage/ssic

    GoldenEggsdiagramhttp://www.goldeneggs.fi/documents/GE-LENOVO-X3500M5-A.pdf 

    http://ibm.com/systems/x/hardware/tower/x3500m5/http://ibm.com/support/entry/portal/docdisplay?lndocid=migr-5096811http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/5464.htmlhttp://lenovopress.com/systemxhttp://www.ibm.com/systems/xbc/cog/http://lenovopress.com/xrefhttp://ibm.com/support/entry/portal/http://ibm.com/support/entry/portal/Downloads/Hardware/Systems/System_x/System_x3500_M5http://www.ibm.com/systems/support/storage/ssichttp://www.goldeneggs.fi/documents/GE-LENOVO-X3500M5-A.pdfhttp://www.goldeneggs.fi/documents/GE-LENOVO-X3500M5-A.pdfhttp://www.ibm.com/systems/support/storage/ssichttp://ibm.com/support/entry/portal/Downloads/Hardware/Systems/System_x/System_x3500_M5http://ibm.com/support/entry/portal/http://lenovopress.com/xrefhttp://www.ibm.com/systems/xbc/cog/http://lenovopress.com/systemxhttp://www.ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/5464.htmlhttp://ibm.com/support/entry/portal/docdisplay?lndocid=migr-5096811http://ibm.com/systems/x/hardware/tower/x3500m5/

  • 8/9/2019 Tips 1242

    56/57

    LenovoSystemx3500M5 56

    NoticesLenovomaynotoffertheproducts,services,orfeaturesdiscussedinthisdocumentinallcountries.ConsultyourlocalLenovorepresentativeforinformationontheproductsandservicescurrentlyavailableinyourarea.AnyreferencetoaLenovoproduct,program,orserviceisnotintendedtostateorimplythatonlythatLenovoproduct,

    program,orservicemaybeused.Anyfunctionallyequivalentproduct,program,orservicethatdoesnotinfringeanyLenovointellectualpropertyrightmaybeusedinstead.However,itistheuser'sresponsibilitytoevaluateandverifytheoperationofanyotherproduct,program,orservice.Lenovomayhavepatentsorpendingpatentapplicationscoveringsubjectmatterdescribedinthisdocument.Thefurnishingofthisdocumentdoesnotgiveyouanylicensetothesepatents.Youcansendlicenseinquiries,inwriting,to:

    Lenovo(UnitedStates),Inc.1009ThinkPlace-BuildingOne Morrisville,NC27560 U.S.A. Attention:LenovoDirectorofLicensing 

    LENOVOPROVIDESTHISPUBLICATION“ASIS”WITHOUTWARRANTYOFANYKIND,EITHEREXPRESSORIMPLIED,INCLUDING,BUTNOTLIMITEDTO,THEIMPLIEDWARRANTIESOFNON-INFRINGEMENT,MERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.Somejurisdictionsdonotallowdisclaimerof

    expressorimpliedwarrantiesincertaintransactions,therefore,thisstatementmaynotapplytoyou.

    Thisinformationcouldincludetechnicalinaccuraciesortypographicalerrors.Changesareperiodicallymadetotheinformationherein;thesechangeswillbeincorporatedinneweditionsofthepublication.Lenovomaymakeimprovementsand/orchangesintheproduct(s)and/ortheprogram(s)describedinthispublicationatanytimewithoutnotice.

    Theproductsdescribedinthisdocumentarenotintendedforuseinimplantationorotherlifesupportapplicationswheremalfunctionmayresultininjuryordeathtopersons.TheinformationcontainedinthisdocumentdoesnotaffectorchangeLenovoproductspecificationsorwarranties.NothinginthisdocumentshalloperateasanexpressorimpliedlicenseorindemnityundertheintellectualpropertyrightsofLenovoorthirdparties.Allinformationcontainedinthisdocumentwasobtainedinspecificenvironmentsandispresentedasanillustration.Theresultobtainedinotheroperatingenvironmentsmayvary.Lenovomayuseordistributeanyoftheinformationyousupplyinanywayitbelievesappropriatewithoutincurringanyobligationtoyou.

     Anyreferencesinthispublicationtonon-LenovoWebsitesareprovidedforconvenienceonlyanddonotinanymannerserveasanendorsementofthoseWebsites.ThematerialsatthoseWebsitesarenotpartofthematerialsforthisLenovoproduct,anduseofthoseWebsitesisatyourownrisk.Anyperformancedatacontainedhereinwasdeterminedinacontrolledenvironment.Therefore,theresultobtainedinotheroperatingenvironmentsmayvarysignificantly.Somemeasurementsmayhavebeenmadeondevelopment-levelsystemsandthereisnoguaranteethatthesemeasurementswillbethesameongenerallyavailablesystems.Furthermore,somemeasurementsmayhavebeenestimatedthroughextrapolation.Actualresultsmayvary.Usersofthisdocumentshouldverifytheapplicabledatafortheirspecificenvironment.

    © Copy r ight Lenovo 2015. Al l r ights reserved.

  • 8/9/2019 Tips 1242

    57/57

    ThisdocumentwascreatedorupdatedonMay7,2015.

    Sendusyourcommentsinoneofthefollowingways:UsetheonlineContact us reviewformfoundat:ibm.com /redbooksSendyourcommentsinane-mailto:

    [email protected]

    Thisdocumentisavailableonlineathttp://lenovopress.com/tips1242.

    Trademarks

    Lenovo,ForThoseWhoDoandtheLenovologoaretrademarksorregisteredtrademarksofLenovointheUnitedStates,othercountries,orboth.TheseandotherLenovotrademarkedtermsaremarkedontheirfirstoccurrenceinthisinformationwiththeappropriatesymbol(®or™),indicatingUSregisteredorcommonlawtrademarksownedbyLenovoatthetimethisinformationwaspublished.Suchtrademarksmayalsoberegisteredorcommonlawtrademarksinothercountries.AcurrentlistofLenovotrademarksisavailableontheWebathttp://www.lenovo.com/legal/copytrade.html.

    ThefollowingtermsaretrademarksofLenovointheUnitedStates,othercountries,orboth:

    Lenovo®RackSwitch™Lenovo(logo)®ServeRAID™ServerProven®Systemx®ToolsCenter™TruDDR4™

    Thefollowingtermsaretrademarksofothercompanies:

    Intel,IntelXeon,Intellogo,IntelInsidelogo,andIntelCentrinologoaretrademarksorregisteredtrademarksofIntelCorporationoritssubsidiariesintheUnitedStatesandothercountries.

    LinuxisatrademarkofLinusTorvaldsintheUnitedStates,othercountries,orboth.

    Microsoft,Windows,andtheWindowslogoaretrademarksofMicrosoftCorporationintheUnitedStates,othercountries,orboth.

    Othercompany,product,orservicenamesmaybetrademarksorservicemarksofothers.

    mailto:[email protected]://lenovopress.com/tips1242http://www.lenovo.com/legal/copytrade.html.http://www.lenovo.com/legal/copytrade.html.http://www.lenovo.com/legal/copytrade.html.http://lenovopress.com/tips1242mailto:[email protected]