8/9/2019 Tips 1242
1/57
LenovoSystemx3500M5 1
Lenovo System x3500 M5Lenovo Press Product Guide
TheLenovoSystemx3500M5serverprovidesoutstandingperformanceforyourbusiness-criticalapplications.Itsenergy-efficientdesignsupportsmorecores,memory,anddatacapacityinascalableToweror5URackpackagethatiseasytoserviceandmanage.WithmorecomputingpowerperwattandthelatestIntelXeonE5-2600v3processors,youcanreducecostswhilemaintainingspeedandavailability.
Suggesteduse:business-criticalworkloads,cloudcomputing,virtualization,virtualdesktop,bigdata,analytics,SAPapplications,databasemanagement,pointofsale
Figure1showstheSystemx3500M5.
Figure1.TheLenovoSystemx3500M5
Did you know?
Thex3500M5offersaflexible,scalabledesignandsimpleupgradepathto32HDDs,withuptosevenPCIe3.0slotsandupto1.5TBofmemory.TheonboardEthernetsolutionprovidesfourstandardintegratedGigabitEthernetportswithoutoccupyingPCIeslots.Comprehensivesystemsmanagementtoolswiththenext-generationIntegratedManagementModuleIImakeiteasytodeploy,integrate,service,andmanage.
8/9/2019 Tips 1242
2/57
LenovoSystemx3500M5 2
Key features
Ahigh-performancedual-sockettowerserver,theLenovoSystemx3500M5candeliverthescalability,reliableperformance,andoptimizedefficiencyforyourbusiness-criticalapplications.Startwiththebasicsandupgradeasyourbusinesschangeswithoutjeopardizingexistinginvestments.VirtualizingthePCinfrastructureintooneservercanprovideaccesstoapowerfulserverwithabundantstoragespace,while
significantlyreducingITcosts.
Scalabi l i ty and performance
Thex3500M5offersthefollowingfeaturestoboostperformance,improvescalability,andreducecosts:
Improvesproductivitybyofferingsuperiorsystemperformancewithuptotwoprocessors(eachwith
upto18cores),upto45MBofL3cache,andupto9.6GT/sQPIinterconnectlinks.
Supportsuptotwoprocessors,36cores,and72threadsmaximizetheconcurrentexecutionofmulti-threadedapplications.
IntelligentandadaptivesystemperformancewithenergyefficientIntelTurboBoostTechnologyallowsCPUcorestorunatmaximumspeedsduringpeakworkloadsbytemporarilygoingbeyond
processorthermaldesignpower(TDP).IntelHyper-ThreadingTechnologyboostsperformanceformultithreadedapplicationsbyenablingsimultaneousmultithreadingwithineachprocessorcore,uptotwothreadspercore.
IntelVirtualizationTechnologyintegrateshardware-levelvirtualizationhooksthatallowoperatingsystemvendorstobetterusethehardwareforvirtualizationworkloads.
IntelAdvancedVectorExtensions2.0(AVX2.0)enableaccelerationofenterprise-classworkloads,includingdatabases,andenterpriseresourceplanning.
Upto2133MHzmemoryspeedswithtwoDIMMsperchannelthatarerunningat2133MHztohelpmaximizesystemperformance.
Upto1.5TBofmemorycapacitywith64GBload-reducedDIMMs,orLRDIMMs(supportfor64GBLRDIMMsisplannedforalaterdate).
The12GbpsSASinternalstorageconnectivitydoublesthedatatransferratecomparedto6GbSASsolutionstomaximizeperformanceofstorageI/O-intensiveapplications.
Upto32drivebayswithinternalbackupandopticaldriveatthesametimeprovideaflexibleandscalableall-in-oneplatformtomeetincreasingdemands.
Flexibleandscalableinternalstorageconfigurationsprovideforupto72TBofstoragecapacity.
Theuseofsolid-statedrives(SSDs)insteadoforalongwithtraditionalspinningharddiskdrives(HDDs)cansignificantlyimproveI/Operformance.AnSSDcansupportupto100timesmoreI/Ooperationspersecond(IOPS)thanatypicalHDD.
TheserverhasfourintegratedGigabitEthernetports.
TheserveroffersuptosevenPCIExpress(PCIe)3.0I/Oexpansionslots.
WithIntelIntegratedI/OTechnology,thePCIExpress3.0controllerisintegratedintotheIntelXeonprocessorE5family.ThisintegrationhelpstodramaticallyreduceI/Olatencyandincreaseoverallsystemperformance.
SupportforuptotwoNVIDIAQuadrographicsprocessingunits(GPUs)tomaximizecomputingpower.
8/9/2019 Tips 1242
3/57
LenovoSystemx3500M5 3
Avai labi l i ty and serviceabi l ity
Thex3500M5providesthefollowingfeaturestosimplifyserviceabilityandincreasesystemuptime:
TheserveroffersChipkill,memorymirroring,andmemoryranksparingforredundancyintheeventofanon-correctablememoryfailure.
Tool-lesscoverremovalprovideseasyaccesstoupgradesandserviceableparts,suchasCPU,memory,andadaptercards.
Offershot-swapdrivesthatsupportRAIDredundancyfordataprotectionandgreatersystemuptime.
Supportstheabilitytohaveredundanthot-swappowersuppliesandredundanthot-swapfanstoprovideavailabilityforbusiness-criticalapplications.
TheoptionallightpathdiagnosticspanelandindividuallightpathLEDsquicklyleadthetechniciantofailed(orfailing)components.Thisfeaturesimplifiesservicing,speedsupproblemresolution,andhelpsimprovesystemavailability.
PredictiveFailureAnalysis(PFA)detectswhensystemcomponents(processors,VRMs,memory,disks,fans,andpowersupplies)operateoutsideofstandardthresholdsandgeneratesproactivealertsinadvanceofpossiblefailure,whichincreasesuptime.
SSDsoffersignificantlybetterreliabilitythantraditionalmechanicalHDDsforgreateruptime.
Built-inIntegratedManagementModuleII(IMM2.1)continuouslymonitorssystemparameters,triggersalerts,andperformsrecoveryactionsifthereisafailuretominimizedowntime.
Built-indiagnosticsbyusingDynamicSystemsAnalysis(DSA)Prebootspeedsuptroubleshootingtaskstoreduceservicetime.
Three-yearcustomerreplaceableunitandonsitelimitedwarranty;nextbusinessday9x5.Optionalserviceupgradesavailable.
Manage abi l i ty and securi ty
Thefollowingpowerfulsystemsmanagementfeaturessimplifylocalandremotemanagementofthex3500M5:
TheserverincludesanIMM2.1tomonitorserveravailabilityandperformremotemanagement.
Integratedindustry-standardUnifiedExtensibleFirmwareInterface(UEFI)enablesimprovedsetup,configuration,andupdatesandsimplifieserrorhandling.
TwointegratedTrustedPlatformModules(TPMs)enableadvancedcryptographicfunctionality,suchasdigitalsignaturesandremoteattestation.
SystemxTrustedPlatformAssurance,anexclusivesetofSystemxsecurityfeaturesandpractices,establishesafoolproofsecurityfoundationforworkloadsbydeliveringfirmwarethatissecurelybuilt,tested,digitallysigned,andverifiedbeforerunning.
Theserveroffersenterprise-classdataprotectionwithoptionalself-encryptingdrivesandsimple,centralizedkeymanagementthroughIBMSecurityKeyLifecycleManagement.
Industry-standardAESNIsupportoffersfaster,strongerencryption.
IBMSystemsDirectorofferscomprehensivesystemsmanagementtoolsthathelptoincreaseuptime,reducecosts,andimproveproductivitythroughadvancedservermanagementcapabilities.
8/9/2019 Tips 1242
4/57
LenovoSystemx3500M5 4
IntelExecuteDisableBitfunctionalitycanhelppreventcertainclassesofmaliciousbufferoverflowattackswhencombinedwithasupportingoperatingsystem.
IntelTrustedExecutionTechnologyprovidesenhancedsecuritythroughhardware-basedresistancetomalicioussoftwareattacks,whichallowsanapplicationtoruninitsownisolatedspacethatisprotectedfromallothersoftwarerunningonasystem.
Energy eff ic iency
Thex3500M5offersthefollowingenergy-efficiencyfeaturestosaveenergy,reduceoperationalcosts,increaseenergyavailability,andcontributetothegreenenvironment:
Energy-efficientplanarcomponentshelploweroperationalcosts.
High-efficiencypowersupplieswith80PLUSPlatinumandTitaniumcertifications.
IntelIntelligentPowerCapabilitypowersindividualprocessorelementsonandoffasneededtoreducepowerdraw.
TheIntelXeonprocessorE5-2600v3productfamiliesoffersignificantlybetterperformanceoverthepreviousgenerationwhilefittingintothesamethermaldesignpower(TDP)limits.
IntelIntelligentPowerCapabilitypowersindividualprocessorelementsonandoffasneededto
reducepowerdraw.
Low-voltageIntelXeonprocessorsdrawlessenergytosatisfydemandsofpowerandthermallyconstraineddatacentersandtelecommunicationenvironments.
Low-voltage1.2VDDR4memoryDIMMsuseupto20%lessenergycomparedto1.35VDDR3DIMMs.
SSDsuseasmuchas80%lesspowerthantraditionalspinning2.5-inchHDDs.
Theserveruseshexagonalventilationholes,whichisapartofCalibratedVectoredCooling™technology.Hexagonalholescanbegroupedmoredenselythanroundholes,whichprovidesmoreefficientairflowthroughthesystem.
IBMSystemsDirectorActiveEnergyManager™providesadvanceddatacenterpowernotificationand
managementtohelpachievelowerheatoutputandreducedcoolingneeds.
8/9/2019 Tips 1242
5/57
LenovoSystemx3500M5 5
Locat ions of key components and connectors
Thefollowingfigureshowsthefrontoftheserver.
Figure2.FrontviewoftheSystemx3500M5
8/9/2019 Tips 1242
6/57
LenovoSystemx3500M5 6
Thefollowingfigureshowstherearoftheserver.
Figure3.RearviewoftheSystemx3500M5
Thefollowingfigureshowsthelocationsofkeycomponentsinsidetheserver.
Figure4.InsideviewoftheSystemx3500M5
8/9/2019 Tips 1242
7/57
LenovoSystemx3500M5 7
Standard specif ications
Thefollowingtableliststhestandardspecifications.
Table1.Standardspecifications(part1)
Com ponents Specificat ion
Machinetype 5464
Formfactor Toweror5URack.
Processor UptotwoIntelXeonprocessorE5-2600v3productfamilyCPUswith18cores(2.8GHzcorespeeds);or14cores(2.6GHz),12cores(upto2.6GHz),10cores(2.3GHz),8cores(upto3.2GHz),6cores(upto2.4GHz),4cores(3.0GHz)
TwoQPIlinksupto9.6GT/seach.Upto2133MHzmemoryspeed.Upto45MBL3cache.
Chipset IntelC612.
Memory Upto24DIMMsockets(12DIMMsperprocessor).RDIMMsandLRDIMMsaresupported.Memorytypescannotbeintermixed.Memoryspeedupto2133MHz.
Memorymaximums
WithRDIMMs:Upto384GBwith24x16GBRDIMMsandtwoprocessorsWithLRDIMMs:Upto1.5TBwith24x64GBLRDIMMsandtwoprocessors
Memoryprotection
ECC,Chipkill(forx4-basedmemoryDIMMs),memorymirroring,andmemoryranksparing
Diskdrivebays Availableconfigurations:Upto32x2.5-inchhot-swapSAS/SATAHDDs
Upto12x3.5-inchhot-swapSAS/SATAHDDsorSSDs
Upto6x3.5-inchhot-swapHDDs+16x2.5-inchhot-swapdrivesHDDs/SSDs
Upto6x3.5-inchsimple-swapSATAHDDs
Additionaldrivebaysfortheaboveconfigurations:Two5.25-inchdrivebaysforopticaldrives
Maximuminternalstorage
72TBwith12x6TB3.5-inchNLSASorNLSATAhot-swapHDDs
51.2TBwith32x1.6TB2.5-inchSAShot-swapSSDs
38.4TBwith32x1.2TB2.5-inchSAShot-swapHDDs
36TBwith6x6TB3.5-inchNLSASorNLSATAsimple-swapHDDs
IntermixofSASandSATAissupported.
Storagecontroller
Onboard6GbSATA:noRAIDsupport
12GbSAS/SATARAID:RAID0,1,10withM1215orM5210.OptionalupgradetoRAID5,50isavailableforM1215.OptionalupgradetoRAID5,50isavailableforM5210(zero-cache;1GBnon-backedcache;1GB,2GBor4GBflash-backedcache).OptionalupgradetoRAID6,60isavailableforM5210withmemorycacheupgrades.12GbSAS/SATAnon-RAID:N2215HBA
Opticaldrivebays
Twohalf-height5.25-inchbaysforopticalortapedrives.SupportsDVD-ROMorMultiburner.
Tapedrivebays Twohalf-height5.25-inchbaysforopticalortapedrives.SupportforoneRDXinternalUSB
tapedrive.
Networkinterfaces
FourintegratedGigabitEthernet1000BASE-Tports(RJ-45)basedonBroadcomBCM5719controller
8/9/2019 Tips 1242
8/57
LenovoSystemx3500M5 8
Table1.Standardspecifications(part2)
Com ponents Specification
PCIExpansionslots
UptosevenslotswithtwoprocessorsandfourslotswhenoneCPUisinstalled.AllslotsarePCIe3.0slots:
Slot1:PCIe3.0x8(x8wired);full-height,half-length
Slot2:PCIe3.0x16(x8wired);full-height,full-lengthSlot3:PCIe3.0x16(x16wired);full-height,full-length
Slot4:PCIe3.0x8(x8wired);full-height,full-length
Slot5:PCIe3.0x8(x8wired);full-height,half-length(requiressecondprocessor)
Slot6:PCIe3.0x16(x16wired);full-height,full-length(requiressecondprocessor)
Slot7:PCIe3.0x16(x16wired)full-height,full-length(requiressecondprocessor)
Slots3and6supportdouble-wideGPUs
Ports Front:TwoUSB2.0ports
Rear:FourUSBports(twoUSB2.0,twoUSB3.0),oneDB-15video,oneRJ-45systemsmanagement,fourRJ-45GbEnetworkports,optionalserialport.
Internal:TwointernalUSB3.0ports(forembeddedhypervisorandinternaltapedrive).OptionalSDMediaAdapter.
Cooling CalibratedVectoredCoolingwithuptofourhot-swapfans(twofansshippedstandardonsingleprocessormodelsandfourfansshippedondualprocessormodels).Forsingle-processormodels,optionalRedundantCoolingKitprovidestwoextrafansforN+1redundancy.
Powersupply Uptotworedundanthot-swap550W,750Wor900WHighEfficiencyPlatinumACpowersupplies,or750WHighEfficiencyTitaniumACpowersupplies.
Hot-swapparts Harddrives,powersupplies,andfans
Systemsmanagement
UEFI,IMM2.1thatisbasedonRenesasSH7758,PredictiveFailureAnalysis,lightpathdiagnosticspanelonthefrontoftheserverwithoptionalupgradekit,AutomaticServerRestart,ToolsCenter,SystemsDirectorandActiveEnergyManager.OptionalIMMAdvancedUpgradesoftwarefeatureforremotepresence.
Securityfeatures Power-onpassword,administrator'spassword,twoTPMs:OntheIMM2.1(TPM1.2)andonthehost(TPM1.2/2.0).Lockablefrontbezel.
Video MatroxG200eR2with16MBmemoryintegratedintotheIMM2.1.Maximumresolutionis1600x1200at75Hzwith16Mcolors.
Operatingsystemssupported
MicrosoftWindowsServer2012R2,2012and2008R2,RedHatEnterpriseLinux6and7,SUSELinuxEnterpriseServer11,VMwarevSphere(ESXi)5.1and5.5.
Limitedwarranty Three-yearcustomer-replaceableunitandonsitelimitedwarrantywith9x5/NBD.
Serviceandsupport
OptionalserviceupgradesareavailablethroughLenovo:4-houror2-hourresponsetime,8-hourfixtime,1-yearor2-yearwarrantyextension,remotetechnicalsupportforLenovohardwareandselectedLenovoandthird-party(Microsoft,Linux,VMware)software.
Dimensions Tower:Width:218mm(8.6in),depth:720mm(28.3in),height:440mm(17.25in).Withrackconversionkit:Width:423mm(16.6in),depth:706mm(27.8in),height:218mm
(8.6in)Weight Tower:45.5kg(100.3lb)fullyconfigured,30.8kg(67.9lb)minimumconfiguration
Withrackconversionkit:44.2kg(97.4lb)fullyconfigured,29.5kg(65lb)minimumconfiguration
8/9/2019 Tips 1242
9/57
LenovoSystemx3500M5 9
Thex3500M5serversareshippedwiththefollowingitems:
StatementofLimitedWarrantyImportantNoticesRegistrationflyerDocumentationCDthatcontainstheInstallationandUser'sGuideOne2.8mC13linecord(country-specific)
Notes: Rackmodelsincludearailkitbutdonotincludeacablemanagementarm.OrdertheCMAseparatelybyusingpartnumber00KC334.EMEAmodelsdonotcontainlinecord.Itmustbepurchasedseparately.
Standard models
Thefollowingtableliststhestandardmodels.
Table2.Standardmodels
M T M * In te l X e on p ro ce ss o rs †
two maximum)
M em ory R AID D rive bays
std / max)
D riv es S lots
std /
max)
G bE O ptical Pow er
supply
std / max)
Towermodels
5464- A2x
1xE5-2603v36C1.6GHz15MB1600MHz85W
1x8GB M1215 8x2.5-inchHS/32
Open 4/7 4 DVD 1x550WHS/2
5464-B2x
1xE5-2609v36C1.9GHz15MB1600MHz85W
1x8GB M1215 8x2.5-inchHS/32
Open 4/7 4 DVD 1x550WHS/2
5464-C2x
1xE5-2620v36C2.4GHz15MB1866MHz85W
1x16GB M1215 8x2.5-inchHS/32
Open 4/7 4 DVD 1x550WHS/2
5464-C4x
1xE5-2620v36C2.4GHz15MB1866MHz85W
1x16GB M1215 6x3.5-inchHS/12
Open 4/7 4 DVD 1x550WHS/2
5464-
D2x
1xE5-2630v38C2.4GHz
20MB1866MHz85W
1x16GB M1215 8x2.5-inch
HS/32
Open 4/7 4 DVD 1x550W
HS/2
5464-G2x
1xE5-2650v310C2.3GHz
25MB2133MHz105W
1x16GB M52101GBFlash
8x2.-inchHS/32
Open 4/7 4 DVD 1x750WHS/2
5464-H2x
1xE5-2670v312C2.3GHz
30MB2133MHz120W
1x16GB M52102GBFlash
8x2.5-inchHS/32
Open 4/7 4 DVD 1x900WHS/2
5464-J2x
1xE5-2680v312C2.5GHz
30MB2133MHz120W
1x16GB M52102GBFlash
8x2.5-inchHS/32
Open 4/7 4 DVD 1x900WHS/2
Rackmodels
5464-C3x
1xE5-2620v36C2.4GHz15MB1866MHz85W
1x16GB M1215 6x3.5-inchHS/12
Open 4/7 4 DVD 1x550WHS/2
5464-G3x
1xE5-2650v310C2.3GHz
25MB2133MHz105W
1x16GB M52101GBFlash
8x2.5-inchHS/32
Open 4/7 4 DVD 1x750WHS/2
*xintheMachineTypeModel(MTM)representsacountry-specificletter(forexample,theEMEAMTMis7983-A5G,andtheUSMTMis7383-A5U).AskaLenovorepresentativeforspecificinformation.†Processordetail:Processorquantityandmodel,cores,corespeed,L3cache,memoryspeed,TDP.
RefertotheSpecificationssectionforinformationaboutstandardfeaturesoftheserver.
8/9/2019 Tips 1242
10/57
LenovoSystemx3500M5 10
TopSel ler and Express models
Thefollowingtableliststheexpressmodels.
Table3.Expressmodels(Part1)
MTM**
Form
factor
Intel Xeon processors†
two maximum)
M emory R AID D rive
bays
std / max)
D rives Slots
std /
max)
O ptica l Pow er
supply
2 max)
UnitedStatesandCanada
5464-EAUTower
1xE5-2609v36C1.9GHz15MB1600MHz85W
1x8GB M1215 6x3.5-inchHS/12
Open 4/7 Multi-burner
1x550W
5464-EBUTower
1xE5-2620v36C2.4GHz15MB1866MHz85W
1x16GB M5120 6x3.5-inchHS/12
Open 4/7 Multi-burner
1x750W
5464-ECUTower
1xE5-2640v38C2.6GHz20MB1866MHz90W
1x16GB M5120 8x2.5-inchHS/32
Open 4/7 Multi-burner
1x750W
5464-EDUTower
2xE5-2609v36C1.9GHz15MB1600MHz85W
2x16GB M51202GBFlash
6x3.5-inchHS/12
Open 4/7 Multi-burner
2x550W
5464-EEUTower 2xE5-2640v38C2.6GHz20MB1866MHz90W 2x16GB M51202GBFlash 8x2.5-inchHS/32 Open 4/7 Multi-burner 2x750W
Europe,MiddleEast&Africa(EMEA)
5464-E1GTower
1xE5-2603v36C1.6GHz15MB1600MHz85W
M1215+RAID5/50
8x2.5-inchHS/32
Open 4/7 Multi-burner
1x550W
5464-E2GTower
1xE5-2609v36C1.9GHz15MB1600MHz85W
1x8GB M1215+RAID5/50
6x3.5-inchHS/12
Open 4/7 Multi-burner
1x550W
5464-E3GTower
1xE5-2620v36C2.4GHz15MB1866MHz85W
1x8GB M51201GBNobackup
8x2.5-inchHS/32
Open 4/7 Multi-burner
2x550W
5464-E4GTower
1xE5-2620v36C2.4GHz15MB1866MHz85W
1x8GB M51201GBFlash
8x2.5-inchHS/32
3x300GB10KSAS
4/7 Multi-burner
2x750W
5464-E5G
Tower
1xE5-2640v38C2.6GHz
20MB1866MHz90W
1x16GB M51202GB
Flash
8x2.5-inch
HS/32
Open 4/7 Multi-
burner
2x750W
LatinAmerica&Brazil
5464-EFxTower
1xE5-2609v36C1.9GHz15MB1600MHz85W
1x8GB M51201GBFlash+Cap
8x2.5-inchHS/32
Open 4/7 DVD 1x550W
5464-EGxTower
1xE5-2620v36C2.4GHz15MB1866MHz85W
1x16GB M51201GBFlash
8x2.5-inchHS/32
Open 4/7 DVD 1x550W
5464-EHxTower
1xE5-2650v310C2.3GHz25MB2133MHz105W
1x16GB M51201GBFlash
8x2.5-inchHS/32
Open 4/7 DVD 1x750W
Japan
5464-E6JTower
1xE5-2603v36C1.6GHz15MB1600MHz85W
1x8GB M51201GBFlash
8x2.5-inchHS/32
Open 4/7 DVD 1x550W
5464-E7JTower
1xE5-2609v36C1.9GHz15MB1600MHz85W
1x8GB M51201GBFlash
8x2.5-inchHS/32
Open 4/7 DVD 1x550W
8/9/2019 Tips 1242
11/57
LenovoSystemx3500M5 11
Table3.Expressmodels(Part2)
MTM**
Form
factor
Intel Xeon processors†
two maximum)
Memory R AID D rive
bays
std / max)
D rives S lots
std /
max)
O ptical Pow er
supply
2 max)
Australia&NewZealand
5464-EIMTower 1xE5-2609v36C1.9GHz15MB1600MHz85W 1x8GB M1215+RAID5/50 6x3.5-inchHS/12 Open 4/7 Multi-burner 1x550W
5464-EJMTower
1xE5-2609v36C1.9GHz15MB1600MHz85W
1x8GB M1215+RAID5/50
8x2.5-inchHS/32
Open 4/7 Multi-burner
1x550W
5464-EKMTower
1xE5-2620v36C2.4GHz15MB1866MHz85W
2x8GB M51201GBFlash+Cap
8x2.5-inchHS/32
Open 4/7 Multi-burner
1x550W
5464-ELMTower
1xE5-2640v38C2.6GHz20MB1866MHz90W
2x8GB M51201GBFlash+Cap
8x2.5-inchHS/32
Open 4/7 Multi-burner
1x750W
**MTM=MachineTypeModel†Processordetail:Processorquantityandmodel,numberofcores,corespeed,L3cache,memoryspeed,TDP.
Table4.TopSellerModels
MTM**
Form
factor
Intel Xeon processors†
two maximum)
M emory R AID D rive
bays
std / max)
D rives Slots
std /
max)
O ptica l Pow er
supply
2 max)
UnitedStatesandCanada
5464-NAYTower
1xE5-2603v36C1.6GHz15MB1600MHz85W
1x8GB M1215 6x3.5-inchHS/12
Open 4/7 Open 1x550W
5464-NBYTower
1xE5-2609v36C1.9GHz15MB1600MHz85W
1x8GB M1215 8x2.5-inchHS/32
Open 4/7 Open 1x550W
5464-NCYTower
1xE5-2620v36C2.4GHz15MB1866MHz85W
1x16GB M1215 8x2.5-inchHS/32
Open 4/7 Open 1x550W
5464-NDYTower
1xE5-2630v38C2.4GHz20MB1866MHz85W
1x16GB M5120 8x2.5-inchHS/32
Open 4/7 Open 1x550W
5464-NEYTower
1xE5-2630v38C2.4GHz20MB1866MHz85W
1x16GB M5120 6x3.5-inchHS/12
Open 4/7 Open 1x550W
5464-NFYTower
1xE5-2650v310C2.3GHz25MB2133MHz105W
1x16GB M5120 8x2.5-inchHS/32
Open 4/7 Open 1x750W
Europe,MiddleEast,andAfrica(EMEA)
5464-K1G 1xE5-2620v36C2.4GHz15MB1866MHz85W
1x16GB M52102GBFlash
8x2.5-inchHS/32
Open 4/7 Multi-burner
1x550W
8/9/2019 Tips 1242
12/57
LenovoSystemx3500M5 12
Processor options
Thex3500M5supportstheprocessoroptionsthatarelistedinthefollowingtable.Theserversupportsuptotwoprocessors.Thistableshowswhichservermodelsfeatureeachprocessorasstandard.Ifthereisnocorrespondingwhere-used modelforaparticularprocessor,thisprocessorisavailablethroughCTOonly.
Table5.Processoroptions
Part
number
Feature
codes* Description
Standard models
where used
81Y7113 A5C8/A5MP IntelXeonE5-2603v36C1.6GHz15MB1600MHz85W A2x
81Y7114 A5C9/A5MQ IntelXeonE5-2609v36C1.9GHz15MB1600MHz85W B2x
81Y7115 A5CA/A5MR IntelXeonE5-2620v36C2.4GHz15MB1866MHz85W C2x,C3x,C4x
00MU332 ASLW/ASLZ IntelXeonE5-2623v34C3.0GHz10MB1866MHz105W -
81Y7116 A5CB/A5MS IntelXeonE5-2630v38C2.4GHz20MB1866MHz85W D2x
00KG052 ARZK/ARZL IntelXeonE5-2630Lv38C1.8GHz20MB1866MHz55W -
81Y7117 A5CC/A5MT IntelXeonE5-2640v38C2.6GHz20MB1866MHz90W -
81Y7118 A5CD/A5MU IntelXeonE5-2650v310C2.3GHz25MB2133MHz105W G2x,G3x
81Y7121 A5CG/A5MX IntelXeonE5-2650Lv312C1.8GHz30MB2133MHz65W -
00MU330 ASLU/ASLX IntelXeonE5-2660v312C2.3GHz30MB2133MHz105W -
00MU331 ASLV/ASLY IntelXeonE5-2667v38C3.2GHz20MB2133MHz135W -
81Y7119 A5CE/A5MV IntelXeonE5-2670v312C2.3GHz30MB2133MHz120W H2x
81Y7120 A5CF/A5MW IntelXeonE5-2680v312C2.5GHz30MB2133MHz120W J2x
00KG038 ARYU/ARYX IntelXeonE5-2690v312C2.6GHz30MB2133MHz135W -
00KG039 ARYV/ARYY IntelXeonE5-2697v314C2.6GHz35MB2133MHz145W -
00KG040 ARYW/ARYZ IntelXeonE5-2699v318C2.8GHz45MB2133MHz145W -
*Thefirstfeaturecodeisforthefirstprocessor;thesecondfeaturecodeisforthesecondprocessor.
8/9/2019 Tips 1242
13/57
LenovoSystemx3500M5 13
Mem ory opt ions
TheSystemx3500M5supportsTruDDR4memory.TruDDRMemoryusesthehighestqualitycomponentsthataresourcedfromTier1DRAMsuppliersandonlymemorythatmeetsourstrictrequirementsisselected.ItiscompatibilitytestedandtunedoneverySystemxservertomaximizeperformanceandreliability.TruDDR4MemoryhasauniquesignatureprogrammedintotheDIMMthat
enablesSystemxserverstoverifywhethertheinstalledmemoryisqualifiedorsupported.BecauseTruDDR4Memoryisauthenticated,certainextendedmemoryperformancefeaturescanbeenabledtoextendperformanceoverindustrystandards.Fromaserviceandsupportstandpoint,Systemxmemoryautomaticallyassumesthesystem'swarranty,andserviceandsupportprovidedworldwide.
Thefollowingtableliststheavailablememoryoptionsforthex3500M5server.
Table6.Memoryoptions
Partnumber
Feature
code
Description M axim um
suppor ted
Standard
mode ls
where used
RDIMMs-2133MHz
46W0784 A5B6 4GBTruDDR4Memory(1Rx8,1.2V)PC4-17000CL152133MHzLPRDIMM
24(12perCPU) -
46W0788 A5B5 8GBTruDDR4Memory(1Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM
24(12perCPU) A2x,B2x
46W0792 A5B8 8GBTruDDR4Memory(2Rx8,1.2V)PC4-17000CL152133MHzLPRDIMM
24(12perCPU)
46W0796 A5B7 16GBTruDDR4Memory(2Rx4,1.2V)PC4-17000CL152133MHzLPRDIMM
24(12perCPU) Allothermodels
LRDIMMs-2133MHz
46W0800 A5B9 32GBTruDDR4Memory(4Rx4,1.2V)PC417000
CL152133MHzLPLRDIMM
24(12perCPU) -
95Y4812* A5UK 64GBTruDDR4Memory(4Rx4,1.2V)PC4-17000CL152133MHzLPLRDIMM
24(12perCPU) -
*Supportfor64GBLRDIMMsisplannedforalaterdate.
Theserversupportsupto12DIMMswhenoneprocessorisinstalledandupto24DIMMswhentwoprocessorsareinstalled.Eachprocessorhasfourmemorychannels;therearethreeDIMMsperchannel.
Thefollowingrulesapplywhenthememoryconfigurationisselected:
TheserversupportsRDIMMsandLRDIMMs.Mixingtypesofmemory(RDIMMsandLRDIMMs)isnotsupported.ThemaximumquantityofDIMMsthatcanbeinstalledintheserverdependsonthenumberofprocessors. AllDIMMsintheserveroperateatthesamespeed,whichisdeterminedasthelowestvalueofthefollowingfactors:
Memoryspeedthatissupportedbythespecificprocessor.LowestofmaximumoperatingspeedsforselectedmemoryconfigurationthatdependsonquantityofDIMMsperchannel,asshownunder"Maximumoperatingspeed"sectioninthefollowingtable.
8/9/2019 Tips 1242
14/57
8/9/2019 Tips 1242
15/57
LenovoSystemx3500M5 15
Internal storage
Theinternaldrivebaysofthex3500M5areshowninthefollowingfigure.
Figure5.Internaldrivebays
TheSystemx3500M5serversupportsthefollowinginternalstorageconfigurations:
Configurationswith2.5-inchhot-swapdrives:
8x2.5-inchhot-swapdrives(1RAIDadapter)16x2.5-inchhot-swapdrives(1RAIDadapter)16x2.5-inchhot-swapdrives(2RAIDadapters)24x2.5-inchhot-swapdrives(1RAIDadapter)24x2.5-inchhot-swapdrives(2RAIDadapters)32x2.5-inchhot-swapdrives(1RAIDadapter)32x2.5-inchhot-swapdrives(2RAIDadapters)
Configurationswith3.5-inchhot-swapdrives:
6x3.5-inchhot-swapharddiskdrives(1RAIDadapter)12x3.5-inchhot-swapharddiskdrives(2RAIDadapters)
Configurationswith2.5-inchand3.5-inchhot-swapdrives:6x3.5-inchhot-swapharddiskdrives+16x2.5-inchhot-swapdrives(2RAIDadapters)
Configurationswith3.5-inchsimple-swapdrives:
6x3.5-inchsimple-swapharddiskdrives(6GbSATAonboardconnectors)6x3.5-inchsimple-swapharddiskdrives(1adapter)
Note :Aconfigurationof12simple-swapdrivesisnotsupported.
Thefollowingdrivetypemixingrulesapply:
Hot-swapSATAHDDsandhot-swapSASHDDscanbeintermixedonthesamebackplane,butcannotbeintermixedinthesameRAIDarray.
Hot-swapSATAHDDsandhot-swapSASHDDscanbeintermixedwithSSDsonthesamebackplane,butSASnorSATAHDDscanbeconfiguredwithSSDswithinthesameRAIDarray.
8/9/2019 Tips 1242
16/57
LenovoSystemx3500M5 16
Backplanes
Thefollowingtableliststheavailablebackplanesforthex3500M5.Standardmodelsshipwithone8x2.5-inchhot-swapbackplaneorone6x3.5-inchhot-swapbackplane,aslisted.
Table8.Internalstoragebackplane(configuretoorder)
Feature
code
Nam e M odels
where used
Maximum
suppor ted
A5D4 Systemx3500M52.5-inchHotSwapSAS:8x2.5-inchhot-swapdrives
Connectto1adapter(2ports)or2adapters(1porteach)
SupportedbyM5210,M1215,orN2215
Allotherstandardmodels
2
A5N5 Systemx3500M52.5-inchHotSwapSAS8-16:8x2.5-inchhot-swapdrives
IncludesaSASexpander
ConnectstobackplaneA5D4tosupportupto16drivesperport
SupportedbyM5210,M1215,orN2215
- 2
A5D5 Systemx3500M53.5-inchHotSwapSAS:
6x3.5-inchhot-swapdrivesSupportedbyM5210,M1215,orN2215
C3x,C4x 2
A5UM Systemx3500M53.5-inchSimpleSwap:6x3.5-inchsimple-swapdrives
ConnectionstoonboardSATAports
- 1
A5D2 Systemx3500M53.5-inchSimpleSwap:6x3.5-inchsimple-swapdrives
ConnectionstoRAIDcontroller
- 1
8/9/2019 Tips 1242
17/57
LenovoSystemx3500M5 17
Thefollowingtablelisttheavailablehot-swapdrivebayupgrades.
Table9.Drivebayupgradeoptions
Option
part numberNa m e
00AL540 8x2.5-inchHot-SwapSAS/SATAUpgradeKitfor16or24HDDs:Forexistingconfigurationswith8xor16x2.5-inchbays Adds8x2.5-inchhot-swapdrives
BackplaneIncludesaSASexpander
SamebackplaneasfeatureA5N5
00AL541 8x2.5-inchHot-SwapSAS/SATAUpgradeKitfor32HDDs:Forexistingconfigurationswith24x2.5-inchbays
Adds8x2.5-inchhot-swapdrives
SamebackplaneasfeatureA5D4
00AL542 6x3.5-inchHot-SwapSAS/SATAUpgradeKitfor12HDDs:Forexistingconfigurationswith6x3.5-inchdrives
Adds6x3.5-inchhot-swapdrives
SamebackplaneasfeatureA5D5
00AL543 6x3.5-inchHot-SwapSAS/SATAUpgradeKitfor22HDDs(Intermix):Forexistingconfigurationswith16x2.5-inchdrives
Adds6x3.5-inchhot-swapdrives
SamebackplaneasfeatureA5D5
00AL544 8x2.5-inchHot-SwapSAS/SATAUpgradeKitfor14HDDs(Intermix):Forexistingconfigurationswith6x3.5-inchdrives
Adds8x2.5-inchhot-swapdrives
SamebackplaneasfeatureA5D4
00KG037 8x2.5-inchHot-SwapSAS/SATAUpgradeKitfor22HDDs(Intermix):Forexistingconfigurationswith6x3.5-inchand8x2.5-inchdrives
Adds8x2.5-inchhot-swapdrives
SamebackplaneasfeatureA5N5
00AL539 SAScableoptionforDualRAIDarray(RAIDadapternotincluded):ForconfigurationswithtwoRAIDcards
Onlyneededwhenupgradingfrom8x2.5-inchdrivesto16,24or32drives,asshowninFigure7.Connectssecondadaptertobackplane
8/9/2019 Tips 1242
18/57
LenovoSystemx3500M5 18
Drive bay configurations
Thefollowingfigureshowshowmodelswitheight2.5-inchdrivebayscanbeupgradedtoatotalof32drivebays.Insuchconfigurations,alldrivesareconnectedtooneRAIDcontroller.SupportedadaptersaretheServeRAIDM5210,ServeRAIDM1215,andN2215hostbusadapter.
Figure6.Configurationsof2.5-inchdriveswithoneRAIDadapter
Thefollowingfigureshowshowmodelswitheight2.5-inchdrivebayscanbeupgradedtoatotalof32drivebaysthatusetwoRAIDcontrollerforaddedperformance.SupportedadaptersaretheServeRAIDM5210,ServeRAIDM1215,andN2215hostbusadapter.
Figure7.Configurationsof2.5-inchdriveswithtwoRAIDadapters
8/9/2019 Tips 1242
19/57
LenovoSystemx3500M5 19
Thefollowingfigureshowshowmodelswithsix3.5-inchhot-swapdrivebayscanbeupgradedto12drivebays.SuchaconfigurationrequirestwoRAIDcontrollers.SupportedadaptersaretheServeRAIDM5210,ServeRAIDM1215,andN2215hostbusadapter.
Figure8.Configurationsof3.5-inchdrives
Forconfigure-to-orderconfigurations,theserveralsosupportssimple-swap3.5-inchdrives.Thesimple-swapdrivescanbeconnectedtothe6GbSATAportsonthesystemboardoftheserverortoaRAIDcontroller.Onlysix3.5-inchdrivesaresupported;aconfigurationof12simple-swapdrivesisnotsupported.
Figure9.Simple-swap3.5-inchdrives
8/9/2019 Tips 1242
20/57
LenovoSystemx3500M5 20
Theserveralsosupportscombinationsof2.5-inchdrivebays(upto16)and3.5-inchdrivebays(6bays).Theupgradepathfrommodelswith2.5-inchdrivesisshowninthefollowingfigure.The3.5-inchdrivesmustbeconnectedtoaseparateRAIDadapter.
Figure10.Combinationsof2.5-inchand3.5-inchdrivebaysfroma2.5-inchbase
Thefollowingfigureshowstheupgradepathfrommodelswith3.5-inchdrives.
Figure11.Combinationsof2.5-inchand3.5-inchdrivebaysfroma3.5-inchbase
8/9/2019 Tips 1242
21/57
8/9/2019 Tips 1242
22/57
LenovoSystemx3500M5 22
TheServeRAIDM5210SAS/SATAControllerhasthefollowingspecifications:
Eightinternal12GbpsSAS/SATAportsUpto12GbpsthroughputperportTwox4HDmini-SASinternalconnectors(SFF-8643)SupportsconnectionstoSAS/SATAHDDsandSSDsandSASExpandersSupportsRAID0,1,and10SupportsRAID5and50withoptionalM5200SeriesRAID5upgradesSupportsRAID6and60withtheoptionalM5200SeriesRAID6upgradeOptionalsupportforself-encryptingdrives(SEDs)withMegaRAIDSafeStore(withRAID5upgrade)Supports1GBnon-backedcacheor1GB,2GBor4GBflash-backedcachePCIe3.0x8hostinterfaceBasedontheLSISAS310812GbpsROCcontroller
TheN2215SAS/SATAHBAhasthefollowingspecifications:
Eightinternal12GbpsSAS/SATAportsUpto12GbpsthroughputperportTwox4HDmini-SASinternalconnectors(SFF-8643)SupportsconnectionstoSAS/SATAHDDsandSSDs
OptimizedforSSDperformanceNoRAIDsupportPCIe3.0x8hostinterfaceBasedontheLSISAS300812Gbpscontroller
Formoreinformation,seethelistofLenovoPressProductGuidesintheRAIDadapterscategoryatthiswebsite:http://lenovopress.com/systemx/raid
http://lenovopress.com/systemx/raidhttp://lenovopress.com/systemx/raid
8/9/2019 Tips 1242
23/57
LenovoSystemx3500M5 23
Internal dr ive options
Thefollowingtablelistsharddriveoptionsforinternaldiskstorageofthex3500M5server.
Table11.Driveoptionsforinternaldiskstorage(Part1)
Part
number
Feature
code
Description M axim um
suppor ted
3.5-inchhot-swapHDDs-12GbpsNLSAS
00FN188 A5VP 2TB7.2K12GbpsNLSAS3.5-inchG2HS512eHDD 12
00FN208 A5VQ 4TB7.2K12GbpsNLSAS3.5-inchG2HS512eHDD 12
00FN228 A5VR 6TB7.2K12GbpsNLSAS3.5-inchG2HS512eHDD 12
3.5-inchhot-swapSEDs-12GbpsNLSAS
00FN238 A5VS 2TB7.2K12GbpsNLSAS3.5-inchG2HS512eSED 12
00FN248 A5VT 4TB7.2K12GbpsNLSAS3.5-inchG2HS512eSED 12
00FN258 A5VU 6TB7.2K12GbpsNLSAS3.5-inchG2HS512eSED 12
3.5-inchhot-swapHDDs-12GbpsNLSATA
81Y9794 A22T 2TB7.2K6GbpsNLSATA3.5-inchG2HSHDD 12
81Y9798 A22S 3TB7.2K6GbpsNLSATA3.5-inchG2HSHDD 12
49Y6002 A3W9 4TB7.2K6GbpsNLSATA3.5-inchG2HSHDD 12
3.5-inchhot-swapHDDs-6GbpsNLSATA
00FN113 A5VD 2TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12
00FN128 A5VF 3TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12
00FN143 A5VH 4TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12
00FN158 A5VK 5TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12
00FN173 A5VM 6TB7.2K6GbpsNLSATA3.5-inchG2HS512eHDD 12
3.5-inchsimple-swapHDDs-6GbpsNLSATA
00FN118 A5VE 2TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6
00FN133 A5VG 3TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6
00FN148 A5VJ 4TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6
00FN163 A5VL 5TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6
00FN178 A5VN 6TB7.2K6GbpsNLSATA3.5-inchG2SS512eHDD 6
81Y9810 A22W 2TB7.2K6GbpsNLSATA3.5-inchG2SSHDD 6
81Y9814 A22V 3TB7.2K6GbpsNLSATA3.5-inchG2SSHDD 6
49Y6012 A3WA 4TB7.2K6GbpsNLSATA3.5-inchG2SSHDD 6
8/9/2019 Tips 1242
24/57
LenovoSystemx3500M5 24
Table11.Driveoptionsforinternaldiskstorage(Part2)
Partnumber
Feature
code
Description M axim um
suppor ted
2.5-inchhot-swap15KHDDs-12GbpsSAS
00AJ081 A4TR 300GB15K6GbpsSAS2.5-inchG3HSHDD 32
00AJ126 A4TS 600GB15K6GbpsSAS2.5-inchG3HSHDD 32
00NA221 ASBB 300GB15K12GbpsSAS2.5"G3HS512eHDD 32
00NA231 ASBD 600GB15K12GbpsSAS2.5"G3HS512eHDD 32
2.5-inchhot-swap10KHDDs-12GbpsSAS
00NA241 ASBF 600GB10K12GbpsSAS2.5"G3HS512eHDD 32
00NA251 ASBH 900GB10K12GbpsSAS2.5"G3HS512eHDD 32
00NA261 ASBK 1.2TB10K12GbpsSAS2.5"G3HS512eHDD 32
00NA271 ASBM 1.8TB10K12GbpsSAS2.5"G3HS512eHDD 32
2.5-inchhot-swap15KHDDs-12GbpsSASself-encyrptingdrive(SED)
00NA281 ASBP 300GB15K12GbpsSAS2.5"G3HS512eSED 32
00NA286 ASBQ 600GB15K12GbpsSAS2.5"G3HS512eSED 32
2.5-inchhot-swap10KHDDs-12GbpsSASSED
00NA291 ASBR 600GB10K12GbpsSAS2.5"G3HS512eSED 32
00NA296 ASBS 900GB10K12GbpsSAS2.5"G3HS512eSED 32
00NA301 ASBT 1.2TB10K12GbpsSAS2.5"G3HS512eSED 32
00NA306 ASBU 1.8TB10K12GbpsSAS2.5"G3HS512eSED 32
2.5-inchhot-swap15KHDDs-12GbpsSAS-SSDHybrid
00NA311 ASBV 300GB15K12GbpsSAS2.5"G3HS512eHybrid 32
00NA321 ASBX 600GB15K12GbpsSAS2.5"G3HS512eHybrid 32
2.5-inchhot-swapSSDs-12GbpsSAS-EnterpriseCapacity
00NA671 ASW6 3.84TB6GbSASEnterpriseCapacityG3HSMLCSSD 32
2.5-inchhot-swapSSDs-12GbpsSAS-Enterprise
00FN379 AS7C 200GB12GSAS2.5-inchMLCG3HSEnterpriseSSD 32
00FN389 AS7E 400GB12GSAS2.5-inchMLCG3HSEnterpriseSSD 32
00FN399 AS7G 800GB12GSAS2.5-inchMLCG3HSEnterpriseSSD 32
00FN409 AS7J 1.6TB12GSAS2.5-inchMLCG3HSEnterpriseSSD 32
2.5-inchhot-swapSSDs-12GbpsSASSED-Enterprise
00FN419 AS7L 400GBSED12GSAS2.5-inchMLCG3HSEnterpriseSSD 32
00FN424 AS7M 800GBSED12GSAS2.5-inchMLCG3HSEnterpriseSSD 32
8/9/2019 Tips 1242
25/57
LenovoSystemx3500M5 25
Table11.Driveoptionsforinternaldiskstorage(Part3)
Partn um b er F ea tu recode
Description M axim um
suppor ted
2.5-inchhot-swap10KHDDs-6GbpsSAS
00AJ096 A4TL 300GB10K6GbpsSAS2.5-inchG3HSHDD 32
00AJ091 A4TM 600GB10K6GbpsSAS2.5-inchG3HSHDD 32
00AJ071 A4TN 900GB10K6GbpsSAS2.5-inchG3HSHDD 32
00AJ146 A4TP 1.2TB10K6GbpsSAS2.5-inchG3HSHDD 32
2.5-inchhot-swapHDDs-6GbpsNLSAS
00AJ086 A4TU 1TB7.2K6GbpsNLSAS2.5-inchG3HSHDD 32
00AJ121 A4TT 500GB7.2K6GbpsNLSAS2.5-inchG3HSHDD 32
2.5-inchhot-swapHDDs-6GbpsNLSATA
00AJ136 A4TW 500GB7.2K6GbpsNLSATA2.5-inchG3HSHDD 32
00AJ141 A4TX 1TB7.2K6GbpsNLSATA2.5-inchG3HSHDD 32
2.5-inchhot-swapSSDs-6GbpsSAS-Enterprise
00AJ217 A4UC 800GBSAS2.5-inchMLCG3HSEnterpriseSSD 32
2.5-inchhot-swapSSDs-6GbpsSATASSDs-Enterprise
00AJ161 A4U4 S3700400GBSATA2.5-inchMLCG3HSEnterpriseSSD 32
2.5-inchhot-swapSSDs-6GbpsSATA-EnterpriseValue
00AJ405 A579 480GBSATA2.5-inchMLCG3HSEnterpriseValueSSD 32
2.5-inchhot-swapSSDs-6GbpsSATA-Entry
00FN347 AS0J 960GBSATA2.5-inchMLCG3HSEntrySSD 32
8/9/2019 Tips 1242
26/57
LenovoSystemx3500M5 26
Internal backup un its
Theserversupportstheinternalbackupunitoptionsthatarelistedinthefollowingtable.
Table12.Internaltapedrives
Part
number
Feature
code
Description M axim um
suppor ted
Drives
- A2U7 RDX3InternalUSBDrive 1
00D2786 A2VE RDXInternalUSB3.0Dockwith320GBCartridge(includesUSBcable) 1
00D2787 A2VF RDXInternalUSB3.0Dockwith500GBCartridge(includesUSBcable) 1
00D2788 A2VG RDXInternalUSB3.0Dockwith1TBCartridge(includesUSBcable) 1
49Y9898 5345 HalfHighLTOGen5InternalSASTapeDrive* 2
00D8924 A3S3 HalfHighLTOUltriumGen6InternalSASTapeDrive* 2
Media
46W6589 A3S6 LTOUltriumGen6SingleMedia(2.6TBnativecapacity)
46C5367 5708 RDX320GBCartridge
46C5368 5709 RDX500GBCartridge
81Y3647 A1VL RDX1TBCartridge
*SupportedwiththeN2215SAS/SATAHBA;alsorequires12GbSASCableforLTOTapedrive,SBB00MV226,featurecodeASTU
USBdevicesareattachedtotheinternalUSBconnector.Foroptionpartnumberorders,theUSBcableisincludedwiththeRDXdrive.ForCTO,usefeaturecode9266.
Formoreinformation,seethelistofProductGuide,RDXUSB3.0DiskBackupSolution ,whichisavailableatthiswebsite:http://lenovopress.com/tips0894
http://lenovopress.com/tips0894http://lenovopress.com/tips0894
8/9/2019 Tips 1242
27/57
LenovoSystemx3500M5 27
Optical dr ives
Theserversupportstheopticaldriveoptionsthatarelistedinthefollowingtable.
Table13.Opticaldrives
Part num ber Feature
code
Description M axim um
suppor ted
Standard models
where used
None* 4154 Half-HighSATADVD-ROM 2 Allstandardmodels
81Y6404 4155 Half-HighSATAMultiburner 2 -
*ThisoptionisavailableviaCTOonlyorisalreadyinstalledinstandardmodels.
Thetwohalf-highdrivesinthetablecanbeinstalledinanyopen5.25-inchdrivebay.
TheHalf-HighSATADVD-ROMdrivesupportsthefollowingmediaandspeedsforreading:
CD-ROM48XCD-DA(DAE)40XCD-R48XCD-RW40XDVD-ROM(singlelayer)16XDVD-ROM(duallayer)12XDVD-R(4.7GB)16XDVD-RDL12XDVD+R16XDVD+RDL12XDVD-RW(4.7GB)12XDVD+RW12XDVD-RAM(4.7/9.4GB)6X
TheHalf-HighSATAmultiburnerdrivesupportsthesamemediaandspeedsforreadingasHH
DVD-ROM.Inaddition,thisdrivesupportsthefollowingmediaandspeedsforwriting:CD-R24XCD-RW4XHighSpeedCD-RW10XUltraSpeedCD-RW16XDVD-R8XDVD-RDL8XDVD+R8XDVD+RDL8XDVD-RW6XDVD+RW8XDVD-RAM3X
8/9/2019 Tips 1242
28/57
LenovoSystemx3500M5 28
I /O expansion options
TheserversupportsuptosevenPCIe3.0slots:Fourslots(1-4)whenoneCPUisinstalledorsevenslotswhentwoCPUsareinstalled.Thefollowingslotformfactorsareavailable:
Slot1:PCIe3.0x8(x8wired);full-height,half-lengthSlot2:PCIe3.0x16(x8wired);full-height,full-length
Slot3:PCIe3.0x16(x16wired);full-height,full-lengthSlot4:PCIe3.0x8(x8wired);full-height,full-lengthSlot5:PCIe3.0x8(x8wired);full-height,half-length(requiressecondprocessor)Slot6:PCIe3.0x16(x16wired);full-height,full-length(requiressecondprocessor)Slot7:PCIe3.0x16(x16wired)full-height,full-length(requiressecondprocessor)
Slots3and6supportdouble-wideGPUs
TheCOMPortBracket,partnumber00KC332,isusedformakinganexternalserialportavailableattherearoftheserver.Thisoptionincludesthebracketandthecable.TheCOMPortoptionismountedinoneofthePCIeslotsandthatPCIeslotcannotbeused.ThefollowingtableliststhePCIeslotoptions.
Table14.Systemx3500M5COMPortKitorderinginformation
Part num ber Feature
code
Description M axim um
suppor ted
00KC332 ARZ0 Systemx3500M5COMPortKit 1
Network adapters
Thex3550M5supportsfourintegratedGigabitEthernetportswiththefollowingfeatures:
ABroadcomBCM5719chip
FourGigabitEthernetports
NICTeaming(loadbalancingandfailover)
Ethernetfeatures:
Compliantwith1GbEthernetIEEE802.3,802.3u,and802.3abPHYspecificationsIntegratedPHYfor10/100/1000Mbpsformultispeed,full,andhalf-duplexauto-negotiation AutomaticMDIcrossoverIEEE802.3x-compliantflowcontrolsupportIEEE1588protocoland802.1AStimesynchronizationimplementationIEEE802.3az-EnergyEfficientEthernet(EEE)
I/OVirtualizationfeatures:
I/OVirtualizationsupportforVMwareNetQueueandMicrosoftvirtualmachinequeue(VMQ)FunctionLevelReset(FLR)IEEE802.1qVirtualLocalAreaNetwork(VLAN)taggingsupport
Statelessoffloadandperformancefeatures:
TCP,IP,andUserDatagramProtocol(UDP)checksumoffloadTCPsegmentationoffload(TCO)LargeSendOffload(LSO)ReceiveSideScaling(RSS)andTransmitSideScaling(TSS)MessageSignalInterrupt(MSI)andMessageSignalInterruptExtension(MSI-X)supportSupportforjumboframesupto9600bytes
8/9/2019 Tips 1242
29/57
LenovoSystemx3500M5 29
Thefollowingtablelistsothersupportednetworkadapters.
Table15.Networkadapters
P ar t n um b er F ea tu re
code
Description M axim um
suppor ted
1 CPU / 2
CPUs)
40GbEthernet
00D9550 A3PN MellanoxConnectX-340GbE/FDRIBVPIAdapter* 4/7
10GbEthernet
44T1370 A5GZ BroadcomNetXtreme2x10GbEBaseTAdapter 4/7
94Y5180 A4Z6 BroadcomNetXtremeDualPort10GbESFP+Adapter* 4/7
00JY830 A5UU EmulexVFA52x10GbESFP+AdapterandFCoE/iSCSISW* 4/7
None AS3M EmulexVFA52x10GbESFP+IntegratedAdapter* 1/1
00JY820 A5UT EmulexVFA52x10GbESFP+PCIeAdapter* 4/700JY824 A5UV EmulexVFA5FCoE/iSCSISWforPCIeAdapterforSystemx(FoD)
(FeaturesonDemandupgradefor00JY820andfeaturecodeAS3M)4/7
49Y7960 A2EC IntelX520DualPort10GbESFP+Adapter* 4/7
49Y7970 A2ED IntelX540-T2DualPort10GBaseTAdapter 4/7
81Y3520 AS73 IntelX7102x10GbESFP+Adapter* 4/7
00D9690 A3PM MellanoxConnectX-310GbEAdapter* 4/7
90Y4600 A3MR QLogic8200DualPort10GbESFP+VFA* 4/7
00Y5624 A3MT QLogic8200VFAFCoE/iSCSILicenseforSystemx(FoD)(FeaturesonDemandupgradefor90Y4600)
4/7
47C9977 A522 SolarflareSFN7122F2x10GbESFP+FlareonUltra* 4/7
1GbEthernet
42C1780 2995 BroadcomNetXtreme2xGbEBaseTAdapter 4/7
90Y9370 A2V4 BroadcomNetXtremeIDualPortGbEAdapter 4/7
90Y9352 A2V3 BroadcomNetXtremeIQuadPortGbEAdapter 4/7
49Y4230 5767 IntelEthernetDualPortServerAdapterI340-T2 4/7
49Y4240 5768 IntelEthernetQuadPortServerAdapterI340-T4 4/7
00AG510 A56L IntelI350-T22xGbEBaseTAdapter 4/7
00AG520 A56M IntelI350-T44xGbEBaseTAdapter 4/7
*RequireSFP+opticaltransceiversorDACcablesthatmustbepurchasedseparately.
Formoreinformation,seethelistofLenovoPressProductGuidesintheNetworkingadapterscategoryat:http://lenovopress.com/systemx/networkadapters
http://lenovopress.com/systemx/networkadaptershttp://lenovopress.com/systemx/networkadapters
8/9/2019 Tips 1242
30/57
LenovoSystemx3500M5 30
Storage host bus adapters
ThefollowingtablelistsstorageHBAsthataresupportedbythex3500M5server.
Table16.Storageadapters
Part num ber Feature
code
Description M axim um
suppor ted
1 CPU / 2 CPUs)
16GbFibreChannel
81Y1668 A2XU Brocade16GbFCSingle-portHBAforSystemx 4/7
81Y1662 A2W6 Emulex16GbFCDual-portHBAforSystemx 4/7
81Y1655 A2W5 Emulex16GbFCSingle-portHBAforSystemx 4/7
00Y3341 A3KX QLogic16GbFCDual-portHBAforSystemx 4/7
00Y3337 A3KW QLogic16GbFCSingle-portHBAforSystemx 4/7
8GbFibreChannel
46M6050 3591 Brocade8GbFCDual-portHBAforSystemx 4/7
46M6049 3589 Brocade8GbFCSingle-portHBAforSystemx 4/7
42D0494 3581 Emulex8GbFCDual-portHBAforSystemx 4/7
42D0485 3580 Emulex8GbFCSingle-portHBAforSystemx 4/7
42D0510 3579 QLogic8GbFCDual-portHBAforSystemx 4/7
42D0501 3578 QLogic8GbFCSingle-portHBAforSystemx 4/7
SAS
46M0907 5982 6GbSASHBAController 4/7
00AE912 A5M0 N2225SAS/SATAHBAforSystemx 4/7
00AE916 A5M1 N2226SAS/SATAHBAforSystemx 4/7
Formoreinformation,seethelistofLenovoPressProductGuidesintheHostbusadapterscategoryatthiswebsite:http://lenovopress.com/systemx/hba
PCIe SSD adap ters
TheservercurrentlydoesnotsupportHighIOPSSSDadapters.
http://lenovopress.com/systemx/hbahttp://lenovopress.com/systemx/hba
8/9/2019 Tips 1242
31/57
LenovoSystemx3500M5 31
GPU adapters
Thex3500M5serversupportsgraphicsprocessingunits(GPUs)thatarelistedinthefollowingtable.UptotwoGPUsaresupported,dependingonthenumberofprocessorsthatareinstalledinaserver.
Table17.GPUadapters
Part num ber Feature code Description M axim um supported
1 CPU / 2 CPUs)
00FP672 A3YV NVIDIAQuadroK6000 1/2
Thefollowingotherrulesapply:
IftwoGPUsareinstalled,theymustbeidentical
ThefirstGPUisinstalledinslot3;thesecondGPUisinstalledinslot6andrequiresthesecondprocessortobeinstalled.
ThenumberofGPUsthatcanbeinstalleddependsonthetypeofpowersupplythatisinstalledandthetypeandnumberofothercomponentsthatareinstalled.Formoreinformation,seethePower
Supplysection.
IfaNVIDIAcardisinstalled,themaximummemorythatcanbeinstalledis1TB.
Powe r suppl ies and redun dant cool ing
Theserversupportsuptotworedundantpowersupplies.Standardmodelscomewithoneortwopowersupplies(dependingonthemodel).
Theserveralsocomesstandardwithtwo(formodelswithoneprocessorinstalled)orfour(formodelswithtwoprocessorsinstalled)hot-swapcoolingfans.Formodelswithonlyoneprocessor,anoptionalRedundantCoolingKitprovidesN+1coolingredundancy.Thefollowingtableliststhepowersuppliesand
redundantcoolingupgradeoptions.
Table18.Powersupplies
Part
number
Feature code Description M axim um
suppor ted
Standard models
where used
00AL533 A5MY Systemx550WHighEffiencyPlatinumACPowerSupply
2 A2x,B2x,C2x,C3x,C4x,D2x
00AL534 A5MZ Systemx750WHighEfficiencyPlatinumACPowerSupply
2 G2x,G3x
00AL536 A5N0 Systemx900WHighEfficencyPlatinumACPowerSupply
2 H2x,J2x
00AL535 A5N1 Systemx750WHighEfficiencyTitaniumACPowerSupply
2 -
None* A5CH Systemx550WHighEfficencyPlatinumACFixedPowerSupply
1 -
00AL537 A5D6 Systemx3500M5RedundantCoolingKit 1 -
*CTOonly
8/9/2019 Tips 1242
32/57
8/9/2019 Tips 1242
33/57
LenovoSystemx3500M5 33
ACpowersupplyoptionsshipswithoutalinecord,itmustbepurchasedseparately.Country-specificlinecordsandrackcablescanbeorderedifneeded,aslistedinthefollowingtable.
Table20.Powercables
Part num ber Feature code Description
Rackpowercables
39Y7932 6263 4.3m,10A/100-250V,C13toIEC320-C14RackPowerCable
39Y7937 6201 1.5m,10A/100-250V,C13toIEC320-C14RackPowerCable
39Y7938 6204 IEC309C20toC13rackjumpercable
Country-specificpowercords
39Y7917 6212 European10AlineC13toCEE7/7(2.8M)
39Y7918 6213 Denmark10AlineC13toDK2-5A(2.8M)
39Y7919 6216 Switzerland10AlineC13toSEV1011(2.8M)
39Y7920 6218 Israel10AlineC13toSI32(2.8M)
39Y7921 6217 Italy10AlineC13toCEE7/7(2.8M)
39Y7922 6214 SouthAfrica10AlineC13toSABS164/1(2.8M)
39Y7923 6215 UnitedKingdom10AlineC13toBS1363(2.8M)
39Y7924 6211 Australia/NZ10AlineC13toSAA-ASC112(2.8M)
39Y7925 6219 Korea7AlineC13toKETI15A/250V(2.8M)
39Y7927 6269 India6AlineC13toFig68(2.8M)
39Y7928 6210 China6AlineC13toGB2099.1(2.8M)
39Y7929 6223 Brazil10AlineC13toNBR6147(2.8M)
39Y7930 6222 Argentina10AlineC13toIRAM2063(2.8M)
39Y7931 6207 PowerCable-C13/NEMA5-15P14ft
00CG265 A53E PowerCordTaiwanACplug10A/250V,2.8M;OPT
00CG267 A53F PowerCordTaiwanACplug15A/125V;2.8M;OPT
46M2592 A1RF 10A/250VC13toNEMA6-15P2.8mlinecord
46M2593 A1RE Japan10A/100VC13toJISC-83032.8mlinecord
8/9/2019 Tips 1242
34/57
LenovoSystemx3500M5 34
Integrated virtualization
TheserversupportstheVMwarevSphere(ESXi)hypervisorononeortwoSDcardswiththeoptionalSDMediaAdapterforSystemx.Thisadapterisinadedicatedconnectoronthesystemboard,asshowninthefollowingfigure.
Figure12.SDMediaAdapterwithoneSDCardinstalled
WhenonlyoneSDcardisinstalledintheadapter,youcancreateupto16volumes,eachofwhichispresentedtoUEFIasabootabledevice.WhentwoSDMediacardsareinserted,volumescanbemirrored(RAID1)acrossbothcards,uptoatotalofeightmirroredvolumes.Theuseofmirroredvolumesimprovessystemavailabilitybecausetheserverremainsoperational,evenifoneSDcardfails.TheRAIDfunctionalityishandledinternallybytheSDMediaAdapter.
Thefollowingtableshowstheavailableoptions.ThetablealsoindicateswhethertheoptionincludestheSDMediaRAIDAdapterandhowmanySDcardsareincluded.
Table21.Virtualizationoptions
Part
number
Feature
code
Description Inc ludes
Adapter
SD
Cards
Included
00ML706 A5TJ SDMediaAdapterforSystemsx(Option00ML706includes2blank32GBSDcards)
Yes 2*
00ML700 AS2V Blank32GBSDMediaforSystemx No 2
None** AS4B RAIDAdapterforSDMediaw/VMwareESXi5.1U2(2SDMedia,RAIDed) Yes 2
None** ASCG RAIDAdapterforSDMediaw/VMwareESXi5.1U2(1SDMedia) Yes 1
*Option00ML706includestwo32GBSDcards;however,forCTOorders,featurecodeA5TJdoesnotincludeSDmediaandthe32GBcardsandVMwarevSpherepreloadmustbeselectedseparately.
**CTOonly.
8/9/2019 Tips 1242
35/57
LenovoSystemx3500M5 35
Systems management
TheservercontainsIMM2.1,whichprovidesadvancedservice-processorcontrol,monitoring,andanalertingfunction.Ifanenvironmentalconditionexceedsathresholdorifasystemcomponentfails,theIMM2.1lightsLEDstohelpyoudiagnosetheproblem,recordstheerrorintheeventlog,andalertsyoutotheproblem.Optionally,theIMM2.1alsoprovidesavirtualpresencecapabilityforremoteserver
managementcapabilities.
TheIMMprovidesremoteservermanagementthroughthefollowingindustry-standardinterfaces:
IntelligentPlatformManagementInterface(IPMI)Version2.0SimpleNetworkManagementProtocol(SNMP)Version3CommonInformationModel(CIM)Webbrowser
TheoptionalIntegratedManagementModuleAdvancedUpgradeisrequiredforenablingremotepresenceandblue-screencapturefeatures.Theremotepresencefeatureprovidesthefollowingfunctions:
Remotelyviewingvideowithgraphicsresolutionsupto1600x1200at75Hzwithupto23bitsperpixelcolors,regardlessofthesystemstateRemotelyaccessingtheserverbyusingthekeyboardandmousefromaremoteclientMappingtheCDorDVDdrive,diskettedrive,andUSBflashdriveonaremoteclient,andmappingISOanddisketteimagefilesasvirtualdrivesthatareavailableforusebytheserverUploadingadisketteimagetotheIMMmemoryandmappingittotheserverasavirtualdrive
Theblue-screencapturefeaturecapturesthevideodisplaycontentsbeforetheIMMrestartstheserverwhentheIMMdetectsanoperating-systemhangcondition.Asystemadministratorcanusetheblue-screencapturetoassistindeterminingthecauseofthehangcondition.Thefollowingtableliststheremotemanagementoption.
Table22.Remotemanagementoption
Part num ber Feature code Description M axim um
suppor ted
90Y3901 A1ML IntegratedManagementModuleAdvancedUpgrade 1
Allstandardmodelsincludebasiclightpathdiagnostics,whichincludesystemLEDsonthefrontoftheserver(seethefollowingfigure)andLEDsnearthemonitoredcomponents(forexample,theDIMMerrorLEDonthesystemboard).TheserveralsooffersanoptionalupgradetosupplyanotherarrayoflightpathdiagnosticLEDsonthefrontofthechassis.
Thefollowingtableliststheorderinginformationforthelightpathdiagnosticspanelupgradekit.
Table23.Remotemanagementoption
Part num ber Feature code Description M axim um
suppor ted
00AL566 A5N3 Systemx3500M5LightpathUpgradeKit 1
8/9/2019 Tips 1242
36/57
LenovoSystemx3500M5 36
ThefollowingfigureshowsthemeaningofeachLED.
Figure13.SystemLEDsandtheoptionallightpathdiagnosticspanel
Note :ThelightpathdiagnosticspanelupgradekitsuppliesthearrayofLEDsthatismountedinabracketthatisinstalledinsidetheserver,asshowninthefollowingfigure.Thelightpathdiagnosticsindicatorsarestillvisibleonthefrontoftheserver,eveniftheupgradekitisnotinstalled.
Figure14.Systemx3500M5LightpathUpgradeKit
IBMSecurityKeyLifecycleManagerforSystemxSEDs-FoD(SKLM-FoD)isanoptionalfeature,whichisavailableinSystemxenvironmentsthatcentralizes,simplifies,andautomatesthedataencryptionkeymanagementprocesstohelpminimizeriskandreduceoperationalcosts.SKLM-FoDoffersasimpleandrobustsolutionforkeystorage,keyserving,andkeylifecyclemanagementforself-encryptingdrives(SEDs)inlocalanddistributedSystemxenvironments.TheFoDupgradecanbeconfiguredwiththeServeRAIDM5210andM1215RAIDcontrollerspairedwithSEDs.ThefollowingtablelistsSKLM-FoDpartnumbers.
8/9/2019 Tips 1242
37/57
LenovoSystemx3500M5 37
Table24.SecurityKeyLifecycleManager-FoDpartnumbers
Part
number
Feature
code
Description M axim um
suppor ted
UnitedStates,Canada,AsiaPacificandJapan
00D9998 A5U1 IBMSKLMforSystemxw/SEDs-FoDperInstallw/1YrS&S 1
00D9999 AS6C IBMSKLMforSystemxw/SEDs-FoDperInstallw/3YrS&S 1
LatinAmerica,Europe,MiddleEastandAfrica
00FP648 A5U1 IBMSKLMforSystemxw/SEDs-FoDperInstallw/1YrS&S 1
00FP649 AS6C IBMSKLMforSystemxw/SEDs-FoDperInstallw/3YrS&S 1
Supported operating systems
Theserversupportsthefollowingoperatingsystems:
MicrosoftWindowsServer2012R2MicrosoftWindowsServer2008R2MicrosoftWindowsServer2012SUSELINUXEnterpriseServer11forAMD64/EM64TSUSELINUXEnterpriseServer11withXenforAMD64/EM64TRedHatEnterpriseLinux6Serverx64EditionRedHatEnterpriseLinux7SUSEEnterpriseLinuxServer(SLES)12SUSELinuxEnterpriseServer12withXENVMwarevSphere5.5(ESXi)VMwarevSphere5.1(ESXi)
Someoperatingsystemsmighthavesupportdelayeduntil60or90daysaftergeneralavailability.For
moreinformationaboutthesupportedspecificversionsandservicelevelsandanyotherprerequisites.seethefollowingServerProven®website:http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml
Physical and electrical specifications
Theserverfeaturesthefollowingdimensionsandweight(approximate):
Tower:
Width:218mm(8.6in)Depth:720mm(28.3in)
Height:440mm(17.25in)
Weightfullyconfigured:45.5kg(100.3lb)Weightminimumconfiguration:30.8kg(67.9lb)
Withrackconversionkit:
Width:423mm(16.6in)Depth:706mm(27.8in)Height:218mm(8.6in)Weightfullyconfigured:44.2kg(97.4lb)Weightminimumconfiguration:29.5kg(65lb)minimumconfiguration
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtmlhttp://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml
8/9/2019 Tips 1242
38/57
LenovoSystemx3500M5 38
Theserverfeaturesthefollowingsupportedenvironment:
DesigntoASHRAEClassA3,ambientof36°Cto40°C(96.8°Fto104°F),withrelaxedsupport:
Supportscloud-likeworkloadwithnoperformancedegradationacceptable(Turbo-Off).Undernocircumstancecananycombinationofworst-caseworkloadandconfigurationresultin
systemshutdownordesignexposureat40°C.Theworst-caseworkload(likeLinpack,Turbo-On)mighthaveperformancedegradation.
Airtemperature:
Serveron:5-40°C(41to104°F);altitude:0-950m(3,100ft)Serveron:5-28°C(41-82°F);altitude:915m(3,000ft)-3050m(10,000ft)Serveroff(withstandbypower):5-45°C(41-113°F)Storage:1-60°C(34-140°F)Shipping:-40-60°C(-40-140°F)
Humidity:8-85%,Max.DewPoint24°C
Electrical:
Modelswith900WACpowersupplies:
100-127(nominal)Vac;50Hzor60Hz;10.3A200-240(nominal)Vac;50Hzor60Hz;5.0AInputkilovolt-amperes(kVA)(approximately):
Minimumconfiguration:0.15kVAMaximumconfiguration:1.194kVA
Modelswith750WPlatinumACpowersupplies:
100-127(nominal)Vac;50Hzor60Hz;8.6A200-240(nominal)Vac;50Hzor60Hz;4.2AInputkilovolt-amperes(kVA)(approximately):
Minimumconfiguration:0.15kVAMaximumconfiguration:1.015kVA
Modelswith750WTitaniumACpowersupplies:
200-240(nominal)Vac;50Hzor60Hz;4.2AInputkilovolt-amperes(kVA)(approximately):
Minimumconfiguration:0.15kVAMaximumconfiguration:0.965kVA
Modelswith550WACpowersupplies:
100to127(nominal)Vac;50Hzor60Hz;6.5A200to240(nominal)Vac;50Hzor60Hz;3.3AInputkilovolt-amperes(kVA)(approximately):
Minimumconfiguration:0.16kVAMaximumconfiguration:0.732kVA
BTUoutput:
Baseconfiguration:2931Btu/hr(859watts)Maximumconfiguration:4043Btu/hr(1185watts)
Acousticalnoiseemissions:
Soundpower,idling:6.0belsSoundpower,operating:6.0bels
8/9/2019 Tips 1242
39/57
LenovoSystemx3500M5 39
Warranty options
TheLenovoSystemx3500M5hasathree-yearwarrantywith24x7standardcallcentersupportand9x5NextBusinessDayonsitecoverage.AlsoavailableareLenovoServiceswarrantymaintenanceupgradesandpost-warrantymaintenanceagreements,withawell-definedscopeofservices,includingservicehours,responsetime,termofservice,andserviceagreementtermsandconditions.
Lenovowarrantyserviceupgradeofferingsarecountry-specific.Notallwarrantyserviceupgradesareavailableineverycountry.FormoreinformationaboutLenovowarrantyserviceupgradeofferingsthatareavailableinyourcountry,visittheLenovoServiceswebsite:
https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do
Thefollowingtableexplainswarrantyservicedefinitionsinmoredetail.
Table25.Warrantyservicedefinitions
Term Description
On-site
service
Aservicetechnicianwillarriveattheclient’slocationforequipmentservice.
24x7x2hour Aservicetechnicianisscheduledtoarriveattheclient’slocationwithintwohoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservicearoundtheclock,everyday,includingLenovoholidays.
24x7x4hour Aservicetechnicianisscheduledtoarriveattheclient’slocationwithinfourhoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservicearoundtheclock,everyday,includingLenovoholidays.
9x5x4hour Aservicetechnicianisscheduledtoarriveattheclient’slocationwithinfourbusinesshoursafterremoteproblemdeterminationiscompleted.Lenovoprovidesservice8:00am-5:00pmintheclient'slocaltimezone,Monday-Friday,excludingLenovoholidays.Forexample,ifacustomerreportsanincidentat3:00pmonFriday,thetechnicianwillarriveby10:00amthefollowingMonday.
9x5nextbusinessday
Aservicetechnicianisscheduledtoarriveattheclient’slocationonthebusinessdayafterremoteproblemdeterminationiscompleted.Lenovoprovidesservice8:00am-5:00pmintheclient'slocaltimezone,Monday-Friday,excludingLenovoholidays.Callsreceivedafter4:00pmlocaltimerequireanextrabusinessdayforservicedispatch.Nextbusinessdayserviceisnotguaranteed.
CommittedRepair
Problemsreceivepriorityhandlingsothatrepairsarecompletedwithinthecommittedtimeof6,8,or24hours.Lenovoprovidesservice24hours/day,everyday,includingLenovoholidays.
The following Lenovo warranty service upgrades are available:
Warranty and maintenance service upgrades:
Three, four, or five years of 9x5 or 24x7 service coverage
Onsite response from next business day to 2 or 4 hoursCommitted repair serviceWarranty extension of up to 5 yearsPost warranty extensions
https://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.dohttps://www-304.ibm.com/sales/gss/download/spst/servicepac/extProductSelectorWWW.do
8/9/2019 Tips 1242
40/57
LenovoSystemx3500M5 40
Committed Repair Service
Committed Repair Services enhances the level of Warranty Service Upgrade or PostWarranty/Maintenance Service offering associated with the selected systems. Offerings vary and areavailable in select countries.
Priority handling to meet defined time frames to restore the failing machine to good workingcondition
Committed repair service levels are measured within the following coverage hours:
24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours24x7x8: Service performed 24 hours per day, 7 days per week, within 8 hours24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours
Hard Drive Retention
Lenovo’s Hard Drive Retention service is a multi-drive hard drive retention offering that ensures yourdata is always under your control, regardless of the number of hard drives that are installed in yourLenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drivewhile Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.The Hard Drive Retention service can be purchased in convenient bundles with our warrantyupgrades and extensions.
Microcode Support
Keeping microcode current helps prevent hardware failures and security exposure. There are twolevels of service: analysis of the installed base and analysis and update where required. Offeringsvary by country and can be bundled with other warranty upgrades and extensions.
Remote Technical Support Services (RTS)
RTS provides comprehensive technical call center support for covered servers, storage, operatingsystems, and applications. Providing a single source for support of hardware and software issues,RTS can reduce problem resolution time, decreasing the cost to address technical problems andincreasing uptime. Offerings are available for Windows, Linux, IBM Systems Director, VMware,Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storagedevices.
8/9/2019 Tips 1242
41/57
LenovoSystemx3500M5 41
Regulatory compliance
Theserverconformstothefollowingstandards:
FCC-VerifiedtocomplywithPart15oftheFCCRules,ClassACanadaICES-003,issue5,ClassA
UL/IEC60950-1
CSAC22.2No.60950-1-07NOM-019 ArgentinaIEC60950-1JapanVCCI,ClassAIEC-60950-1(CBCertificateandCBTestReport) Australia/NewZealandAS/NZSCISPR22:2006,ClassA;AS/NZS60950.1TaiwanBSMICNS13438,ClassA;CNS14336-1GB9254ClassA,GB17625.1ChinaCCCGB4943.1KoreaKN22,ClassA;KN24
External disk storage expansion
Theserversupportsattachmenttoexternalstorageexpansionenclosures,suchastheEXP2500series,byusingtheServeRAIDM5225SAS/SATAController.TheservercanalsobeattachedtosupportedexternalstoragesystemsbyusingasupportedHBA.Formoreinformation,seethefollowingtable.
Table26.RAIDcontrollersandoptionsforexternaldiskstorageexpansion
Partnumber
Feature
code
Descript ion M axim um
suppor ted
Standard models
where used
12GbRAIDcontrollers
00AE938 A5ND ServeRAIDM5225-2GBSAS/SATAController 4 -
FeatureonDemand(FoD)upgradesfortheM5225
47C8706 A3Z5 ServeRAIDM5200SeriesRAID6Upgrade 1* -
47C8710 A3Z7 ServeRAIDM5200SeriesPerformance Accelerator
1* -
47C8712 A3Z8 ServeRAIDM5200SeriesSSDCachingEnabler 1* -
*OneFoDupgradefortheM5225activatesthefeatureonallM5225controllersthatareinstalledinaserver.
TheServeRAIDM5225SAS/SATAControllerhasthefollowingspecifications:
Eightexternal12GbpsSAS/SATAportsSupports12,6,and3Gb/sSASand6and3Gb/sSATAdatatransferratesTwoexternalx4mini-SASHDconnectors(SFF-8644)
Supports2GBflash-backedcache(standard)SupportsRAIDlevels0,1,5,10,and50(standard)SupportsRAID6and60withtheoptionalM5200SeriesRAID6UpgradeSupportsoptionalM5200SeriesPerformanceAcceleratorandSSDCachingupgradesPCIex8Gen3hostinterfaceBasedontheLSISAS310812GbpsROCcontrollerSupportsconnectivitytotheEXP2512andEXP2524storageexpansionenclosures
FormoreinformationabouttheServeRAIDM5225,seetheLenovoPressProductGuideathttp://lenovopress.com/tips1258
http://lenovopress.com/tips1258http://lenovopress.com/tips1258
8/9/2019 Tips 1242
42/57
LenovoSystemx3500M5 42
TheServeRAIDM5225SAS/SATAControllersupportsconnectivitytoexternalexpansionenclosuresthatarelistedinthefollowingtable.Uptonineexpansionenclosurescanbedaisy-chainedperoneM5225externalport.Forbetterperformance,distributeexpansionenclosuresevenlyacrossbothM5225ports.
Table27.Externalexpansionenclosures
Partnum ber Description M axim um quantity supported per one M 5225
70F0/70F1 LenovoThinkServerSA120 8
610012X EXP2512StorageEnclosure 17
610024X EXP2524StorageEnclosure 9
Lenovo ThinkServer SA120 support
FordetailsaboutsupporteddrivesandcablesfortheLenovoThinkServerSA120,seetheLenovoPressProductGuide:http://lenovopress.com/tips1234
EXP2512 and E XP2524 suppor t
TheexternalSAScablesthatarelistedinthefollowingtablesupportconnectivitybetweenexternalexpansionenclosuresandtheServeRAIDM5225SAS/SATAController.
Table28.ExternalSAScablesforexternalstorageexpansionenclosures
Partnum ber Descript ion M axim um quantity supported per one enclosure
ServertoExpansionenclosureconnectivity(Mini-SASHDx4toMini-SASx4)
00MJ162 0.6mSASCable(mSASHDtomSAS) 1
00MJ163 1.5mSASCable(mSASHDtomSAS) 1
00MJ166 3mSASCable(mSASHDtomSAS) 1
ExpansionenclosuretoExpansionenclosureconnectivity(Mini-SASx4toMini-SASx4)
39R6529 1mSASCable 1
39R6531 3mSASCable 1
http://lenovopress.com/tips1234http://lenovopress.com/tips1234
8/9/2019 Tips 1242
43/57
LenovoSystemx3500M5 43
ThefollowingtablelistsdrivesthataresupportedbyEXP2512externalexpansionenclosures.
Table29.DriveoptionsforEXP2512externalexpansionenclosures
Partnum ber Descript ion M axim um quantity supportedper one enclosure
3.5-inchNLSASHSHDDs
00NC555 2TB7,200rpm6GbSASNL3.5-inchHDD 12
00NC557 3TB7,200rpm6GbSASNL3.5-inchHDD 12
00NC559 4TB7,200rpm6GbSASNL3.5-inchHDD 12
ThefollowingtablelistsHDDsthataresupportedbyEXP2524externalexpansionenclosures.
Table30.DriveoptionsforEXP2524externalexpansionenclosures
Partnum ber Description M axim um quant ity supportedper one enclosure
2.5-inchNLSASHSHDDs
00NC571 1TB7,200rpm6GbSASNL2.5-inchHDD 24
2.5-inchSASHSHDDs
00NC561 146GB15,000rpm6GbSAS2.5-inchHDD 24
00NC563 300GB15,000rpm6GbSAS2.5-inchHDD 24
00NC565 600GB10,000rpm6GbSAS2.5-inchHDD 24
00NC567 900GB10,000rpm6GbSAS2.5-inchHDD 24
00NC569 1.2TB10,000rpm6GbSAS2.5-inchHDD 24
2.5-inchSASHSSSDs
00NC573 200GB6GbSAS2.5-inchSSD 24
00NC575 400GB6GbSAS2.5-inchSSD 24
8/9/2019 Tips 1242
44/57
LenovoSystemx3500M5 44
External disk storage system s
ThefollowingtableliststheexternalstoragesystemsthataresupportedbytheserverandcanbeorderedthroughtheSystemxsaleschannel.
Table31.Externaldiskstoragesystems
Part num ber Description
2071CU2 IBMStorwizeV3500LFFDualControlEnclosure
2071CU3 IBMStorwizeV3500SFFDualControlEnclosure
6099L2C IBMStorwizeV37003.5-inchStorageControllerUnit
6099S2C IBMStorwizeV37002.5-inchStorageControllerUnit
6099T2C IBMStorwizeV37002.5-inchDCStorageControllerUnit
6194L2C IBMStorwizeV5000LFFControlEnclosure
6194LEU IBMStorwizeV5000LFFExpansionEnclosure
6194S2C IBMStorwizeV5000SFFControlEnclosure
6194SEU IBMStorwizeV5000SFFExpansionEnclosure
6195SC5 IBMStorwizeV70002.5-inchStorageControllerUnit
6195LEF IBMStorwizeV70003.5-inchStorageExpansionUnit
6195SEF IBMStorwizeV70002.5-inchStorageExpansionUnit
Formoreinformation,seethelistofProductGuidesintheSystemStoragecategoryatthiswebsite:http://lenovopress.com/systemx/externalstorage
http://lenovopress.com/systemx/externalstoragehttp://lenovopress.com/systemx/externalstorage
8/9/2019 Tips 1242
45/57
LenovoSystemx3500M5 45
External backup units
Theserversupportstheexternalbackupattachmentoptionsthatarelistedinthefollowingtable.
Table32.Externalbackupoptions
Part num ber Description
Externaltapeexpansionenclosuresforinternaltapedrives
87651UX 1UTapeDriveEnclosure
87651NX 1UTapeDriveEnclosure(withNema5-15PLineCord)
Tapeenclosureadapters(withcables)
44E8869 USBEnclosureAdapterKit
40K2599 SASEnclosureAdapterKit
Internalbackupdrivessupportedbyexternaltapeenclosures
00D2786 RDXInternalUSB3.0Dockwith320GBCartridge
00D2787 RDXInternalUSB3.0Dockwith500GBCartridge
00D2788 RDXInternalUSB3.0Dockwith1TBCartridge
49Y9898 HalfHighLTOGen5InternalSASTapeDrive
00D8924 HalfHighLTOUltriumGen6InternalSASTapeDrive
Externalbackupunits*
362532Y RDXExternalUSB3.0Dockwith320GBCartridge
362550Y RDXExternalUSB3.0Dockwith500GBCartridge
36251TY RDXExternalUSB3.0Dockwith1TBCartridge
3628L5X HalfHighLTOGen5ExternalSASTapeDrive(withUSlinecord)
3628N5X HalfHighLTOGen5ExternalSASTapeDrive(withoutl inecord)
*TheseexternaltapedrivescanbeorderedthroughtheSystemxsaleschannel.Theservermightsupportothertapedrivesthatarenotlistedinthistable.Formoreinformation,seetheIBMSystemStorageInteroperationCenter(SSIC)atthiswebsite:
http://www.ibm.com/systems/support/storage/ssic
Formoreinformation,seethelistofLenovoPressProductGuidesintheBackupunitscategoryatthiswebsite:http://lenovopress.com/systemx/tape
http://www.ibm.com/systems/support/storage/ssichttp://lenovopress.com/systemx/tapehttp://lenovopress.com/systemx/tapehttp://www.ibm.com/systems/support/storage/ssic
8/9/2019 Tips 1242
46/57
LenovoSystemx3500M5 46
Top-o f-rack Ethernet switches
Theserversupportsthetop-of-rackEthernetswitchesthatarelistedinthefollowingtable.
Table33.Top-of-rackswitches
Part num ber Descript ion
1Gbtop-of-rackswitches
7159BAX LenovoRackSwitchG7028(ReartoFront)
7159CAX LenovoRackSwitchG7052(ReartoFront)
715952F LenovoRackSwitchG8052(FronttoRear)
7159G52 LenovoRackSwitchG8052(ReartoFront)
10Gbtop-of-rackswitches
7159BF7 LenovoRackSwitchG8124E(FronttoRear)
7159BR6 LenovoRackSwitchG8124E(ReartoFront)
715964F LenovoRackSwitchG8264(FronttoRear)
7159G64 LenovoRackSwitchG8264(ReartoFront)
7159DFX LenovoRackSwitchG8264CS(FronttoRear)
7159DRX LenovoRackSwitchG8264CS(ReartoFront)
7159CFV LenovoRackSwitchG8272(FronttoRear)
7159CRW LenovoRackSwitchG8272(ReartoFront)
7159GR5 LenovoRackSwitchG8296(FronttoRear)
7159GR6 LenovoRackSwitchG8296(ReartoFront)
40Gbtop-of-rackswitches
7159BFX LenovoRackSwitchG8332(FronttoRear)
7159BRX LenovoRackSwitchG8332(ReartoFront)
Formoreinformation,seethelistofLenovoPressProductGuidesintheTop-of-rackswitchescategoryatthiswebsite:http://lenovopress.com/systemx/tor
http://lenovopress.com/systemx/torhttp://lenovopress.com/systemx/tor
8/9/2019 Tips 1242
47/57
LenovoSystemx3500M5 47
Uninterruptible po wer sup ply units
Theserversupportsattachmentstotheuninterruptiblepowersupply(UPS)unitsthatarelistedinthefollowingtable.
Table34.Uninterruptiblepowersupplyunits(Part1)
Part num ber Description
TowerUPSunits
55951AX T1kVATowerUPS(100-125VAC)
55951KX T1kVATowerUPS(200-240VAC)
55952AX T1.5kVATowerUPS(100-125VAC)
55952KX T1.5kVATowerUPS(200-240VAC)
53961AX 1000VALCDTowerUPS(120V)
53961JX 1000VALCDTowerUPS(100V)
53961KX 1000VALCDTowerUPS(230V)
53962AX 1500VALCDTowerUPS(120V)
53962JX 1500VALCDTowerUPS(100V)
53962KX 1500VALCDTowerUPS(230V)
Rack-mountedortowerUPSunits
55941AX RT1.5kVA2URackorTowerUPS(100-125VAC)
55941KX RT1.5kVA2URackorTowerUPS(200-240VAC)
55942AX RT2.2kVA2URackorTowerUPS(100-125VAC)
55942KX RT2.2kVA2URackorTowerUPS(200-240VAC)
55943AX RT3kVA2URackorTowerUPS(100-125VAC)
55943KX RT3kVA2URackorTowerUPS(200-240VAC)
55945KX RT5kVA3URackorTowerUPS(200-240VAC)
55946KX RT6kVA3URackorTowerUPS(200-240VAC)
55948KX RT8kVA6URackorTowerUPS(200-240VAC)
55949KX RT11kVA6URackorTowerUPS(200-240VAC)
55948PX RT8kVA6U3:1PhaseRackorTowerUPS(380-415VAC)
55949PX RT11kVA6U3:1PhaseRackorTowerUPS(380-415VAC)
8/9/2019 Tips 1242
48/57
LenovoSystemx3500M5 48
Table34.Uninterruptiblepowersupplyunits(Part2)
Part num ber Description
Rack-mountedUPSunits
53951AX 1500VALCD2URackUPS(100V/120V)
53951KX 1500VALCD2URackUPS(230V)
53952AX 2200VALCD2URackUPS(100V/120V)
53952KX 2200VALCD2URackUPS(230V)
53953AX 3000VALCD3URackUPS(100V/120V)
53953JX 3000VALCD3URackUPS(200V/208V)
53956AX 6000VALCD4URackUPS(200V/208V)
53956KX 6000VALCD4URackUPS(230V)
53959KX 11000VALCD5URackUPS(200V/208V/230V)
24195KX UPS5000
21303RX UPS7500XHV
21304RX UPS10000XHV
Formoreinformation,seethelistofLenovoPressProductGuidesinthePowerinfrastructurecategoryatthiswebsite:http://lenovopress.com/systemx/power
http://lenovopress.com/systemx/powerhttp://lenovopress.com/systemx/power
8/9/2019 Tips 1242
49/57
LenovoSystemx3500M5 49
Powe r distr ibution un its
Theserversupportsattachmentstothepowerdistributionunits(PDUs)arelistedinthefollowingtable.
Table35.Powerdistributionunits(Part1)
Part num ber Description
SwitchedandMonitoredPDUs
46M4002 1U9C19/3C13ActiveEnergyManagerDPIPDU
46M4003 1U9C19/3C13ActiveEnergyManager60A3PhasePDU
46M4004 1U12C13ActiveEnergyManagerDPIPDU
46M4005 1U12C13ActiveEnergyManager60A3PhasePDU
46M4167 1U9C19/3C13SwitchedandMonitored30A3PhasePDU
46M4116 0U24C13SwitchedandMonitored30APDU
46M4119 0U24C13SwitchedandMonitored32APDU
46M4134 0U12C19/12C13SwitchedandMonitored50A3PhasePDU
46M4137 0U12C19/12C13SwitchedandMonitored32A3PhasePDU
EnterprisePDUs
71762MX UltraDensityEnterprisePDUC19PDU+(WW)
71762NX UltraDensityEnterprisePDUC19PDU(WW)
71763MU UltraDensityEnterprisePDUC193Phase60APDU+(NA)
71763NU UltraDensityEnterprisePDUC193Phase60APDU(NA)
39M2816 DPIC13EnterprisePDUwithoutl inecord
39Y8923 DPI60AThreePhaseC19EnterprisePDUwithIEC3093P+G(208V)fixedlinecord
39Y8941 DPISinglePhaseC13EnterprisePDUwithoutlinecord
39Y8948 DPISinglePhaseC19EnterprisePDUwithoutlinecord
Front-endPDUs
39Y8934 DPI32amp/250VFront-endPDUwithIEC3092P+Gndconnector
39Y8935 DPI63amp/250VFront-endPDUwithIEC3092P+Gndconnector
39Y8938 30amp/125VFront-endPDUwithNEMAL5-30Pconnector
39Y8939 30amp/250VFront-endPDUwithNEMAL6-30Pconnector
39Y8940 60amp/250VFront-endPDUwithIEC30960A2P+N+Gndconnector
8/9/2019 Tips 1242
50/57
LenovoSystemx3500M5 50
Table35.Powerdistributionunits(Part2)
Part num ber Descript ion
UniversalPDUs
39Y8951 DPIUniversalRackPDUwithUSLVandHVlinecords
39Y8952 DPIUniversalRackPDUwithCEE7-VIIEuropeLC
39Y8953 DPIUniversalRackPDUwithDenmarkLC
39Y8954 DPIUniversalRackPDUwithIsraelLC
39Y8955 DPIUniversalRackPDUwithItalyLC
39Y8956 DPIUniversalRackPDUwithSouthAfricaLC
39Y8957 DPIUniversalRackPDUwithUKLC
39Y8958 DPIUniversalRackPDUwithAS/NZLC
39Y8959 DPIUniversalRackPDUwithChinaLC
39Y8962 DPIUniversalRackPDU(Argentina)
39Y8960 DPIUniversalRackPDU(Brazil)
39Y8961 DPIUniversalRackPDU(India)
0UBasicPDUs
46M4122 0U24C1316A3PhasePDU
46M4125 0U24C1330A3PhasePDU
46M4128 0U24C1330APDU
46M4131 0U24C1332APDU
46M4140 0U12C19/12C1360A3PhasePDU
46M4143 0U12C19/12C1332A3PhasePDU
Formoreinformation,seethelistofLenovoPressProductGuidesinthePowerinfrastructurecategoryatthiswebsite:http://lenovopress.com/systemx/power
http://lenovopress.com/systemx/powerhttp://lenovopress.com/systemx/power
8/9/2019 Tips 1242
51/57
LenovoSystemx3500M5 51
Rack options
Thex3500M5servercanbeinstalledintherackwiththeTowertoRackConversionKit(00AL538).Theresultingserverisa5Urack-mountableserver,asshowninthefollowingfigure.
Figure15.Thex3500M5withthe5UTowertoRackConversionKit(includedslidekitshown)
TheTowertoRackConversionKit(00AL538)includesacablemanagementarm;however,standardrackmodels(forexample,5464-C3xandG3x)donotincludeacablemanagementarm.Thefore,thearmmustbeorderedseparatelybyusingpartnumber00KC334.
8/9/2019 Tips 1242
52/57
LenovoSystemx3500M5 52
Thetower-to-rackconversionkit,supportedcablemanagementarmkit,rackconsoleswitches,monitorkits,andmanagementgatewaysarelistedinthefollowingtable.
Table36.Rackoptions
Part num ber Feature code Description
Rackoptionsforthex3500M5
00KC334 ARZ2 Systemx3500M5CableManagementKit
00AL538 A5N4 Systemx3500M5TowertoRackConversionKit
Monitorkitsandkeyboardtrays
17238BX 1723HC1fcA3EK 1U18.5"StandardConsole
17238EX 1723HC1fcA3EL 1U18.5"EnhancedMediaConsole
Consoleswitches
1754D2X 1754HC2fc6695 Global4x2x32ConsoleManager(GCM32)
1754D1X 1754HC1fc6694 Global2x2x16ConsoleManager(GCM16)
1754A2X 1754HC4fc0726 Local2x16ConsoleManager(LCM16)
1754A1X 1754HC3fc0725 Local1x8ConsoleManager(LCM8)
Consolecables
43V6147 3757 SingleCableUSBConversionOption(UCO)
39M2895 3756 USBConversionOption(4PackUCO)
46M5383 5341 VirtualMediaConversionOptionGen2(VCO2)
46M5382 5340 SerialConversionOption(SCO)
Universalmanagementgatewayandcables
3858D3X 3858HC1fcA4X1 AvocentUniversalManagementGateway6000
00AK142 A4X4 UMKVMModuleVGA+SDDualRJ45
Formoreinformation,seethelistofLenovoPressProductGuidesintheRackcabinetsandoptionscategoryatthiswebsite:http://lenovopress.com/systemx/rack
http://lenovopress.com/systemx/rackhttp://lenovopress.com/systemx/rack
8/9/2019 Tips 1242
53/57
8/9/2019 Tips 1242
54/57
LenovoSystemx3500M5 54
Lenovo Financial Services
LenovoFinancialServicesreinforcesLenovo’scommitmenttodeliverpioneeringproductsandservicesthatarerecognizedfortheirquality,excellence,andtrustworthiness.LenovoFinancialServicesoffersfinancingsolutionsandservicesthatcomplementyourtechnologysolutionanywhereintheworld.
Wearededicatedtodeliveringapositivefinanceexperienceforcustomerslikeyouwhowanttomaximizeyourpurchasepowerbyobtainingthetechnologyyouneedtoday,protectagainsttechnologyobsolescence,andpreserveyourcapitalforotheruses.
Weworkwithbusinesses,non-profitorganizations,governmentsandeducationalinstitutionstofinancetheirentiretechnologysolution.Wefocusonmakingiteasytodobusinesswithus.Ourhighlyexperiencedteamoffinanceprofessionalsoperatesinaworkculturethatemphasizestheimportanceofprovidingoutstandingcustomerservice.Oursystems,processesandflexiblepoliciessupportourgoalofprovidingcustomerswithapositiveexperience.
Wefinanceyourentiresolution.Unlikeothers,weallowyoutobundleeverythingyouneedfromhardwareandsoftwaretoservicecontracts,installationcosts,trainingfees,andsalestax.Ifyoudecideweeksormonthslatertoaddtoyoursolution,wecanconsolidateeverythingintoasingleinvoice.
OurPremierClientservicesprovidelargeaccountswithspecialhandlingservicestoensurethesecomplextransactionsareservicedproperly.Asapremierclient,youhaveadedicatedfinancespecialistwhomanagesyouraccountthroughitslife,fromfirstinvoicethroughassetreturnorpurchase.Thisspecialistdevelopsanin-depthunderstandingofyourinvoiceandpaymentrequirements.Foryou,thisdedicationprovidesahigh-quality,easy,andpositivefinancingexperience.
ForyourregionspecificofferspleaseaskyourLenovosalesrepresentativeoryourtechnologyproviderabouttheuseofLenovoFinancialServices.Formoreinformation,seethefollowingLenovowebsite:http://www.lenovo.com/services_warranty/us/en/financial_services.html
http://www.lenovo.com/services_warranty/us/en/financial_services.htmlhttp://www.lenovo.com/services_warranty/us/en/financial_services.html
8/9/2019 Tips 1242
55/57
LenovoSystemx3500M5 55
Related p ubl ications a nd l inks
Formoreinformation,seethefollowingresources:
LenovoSystemx3500M5productpage:http://ibm.com/systems/x/hardware/tower/x3500m5/
InstallationandServiceGuide:http://ibm.com/support/entry/portal/docdisplay?lndocid=migr-5096811
ServerProvenhardwarecompatibilitypageforthex3500M5:http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/5464.html
LenovoPressProductGuidesforSystemxserversandoptions:http://lenovopress.com/systemx
SystemxConfigurationandOptionsGuide :http://www.ibm.com/systems/xbc/cog/
xREF:SystemxReference :http://lenovopress.com/xref
SystemxSupportPortal:http://ibm.com/support/entry/portal/http://ibm.com/support/entry/portal/Downloads/Hardware/Systems/System_x/System_x3500_M5
IBMSystemStorageInteroperationCenter(SSIC):http://www.ibm.com/systems/support/storage/ssic
GoldenEggsdiagramhttp://www.goldeneggs.fi/documents/GE-LENOVO-X3500M5-A.pdf
http://ibm.com/systems/x/hardware/tower/x3500m5/http://ibm.com/support/entry/portal/docdisplay?lndocid=migr-5096811http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/5464.htmlhttp://lenovopress.com/systemxhttp://www.ibm.com/systems/xbc/cog/http://lenovopress.com/xrefhttp://ibm.com/support/entry/portal/http://ibm.com/support/entry/portal/Downloads/Hardware/Systems/System_x/System_x3500_M5http://www.ibm.com/systems/support/storage/ssichttp://www.goldeneggs.fi/documents/GE-LENOVO-X3500M5-A.pdfhttp://www.goldeneggs.fi/documents/GE-LENOVO-X3500M5-A.pdfhttp://www.ibm.com/systems/support/storage/ssichttp://ibm.com/support/entry/portal/Downloads/Hardware/Systems/System_x/System_x3500_M5http://ibm.com/support/entry/portal/http://lenovopress.com/xrefhttp://www.ibm.com/systems/xbc/cog/http://lenovopress.com/systemxhttp://www.ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/5464.htmlhttp://ibm.com/support/entry/portal/docdisplay?lndocid=migr-5096811http://ibm.com/systems/x/hardware/tower/x3500m5/
8/9/2019 Tips 1242
56/57
LenovoSystemx3500M5 56
NoticesLenovomaynotoffertheproducts,services,orfeaturesdiscussedinthisdocumentinallcountries.ConsultyourlocalLenovorepresentativeforinformationontheproductsandservicescurrentlyavailableinyourarea.AnyreferencetoaLenovoproduct,program,orserviceisnotintendedtostateorimplythatonlythatLenovoproduct,
program,orservicemaybeused.Anyfunctionallyequivalentproduct,program,orservicethatdoesnotinfringeanyLenovointellectualpropertyrightmaybeusedinstead.However,itistheuser'sresponsibilitytoevaluateandverifytheoperationofanyotherproduct,program,orservice.Lenovomayhavepatentsorpendingpatentapplicationscoveringsubjectmatterdescribedinthisdocument.Thefurnishingofthisdocumentdoesnotgiveyouanylicensetothesepatents.Youcansendlicenseinquiries,inwriting,to:
Lenovo(UnitedStates),Inc.1009ThinkPlace-BuildingOne Morrisville,NC27560 U.S.A. Attention:LenovoDirectorofLicensing
LENOVOPROVIDESTHISPUBLICATION“ASIS”WITHOUTWARRANTYOFANYKIND,EITHEREXPRESSORIMPLIED,INCLUDING,BUTNOTLIMITEDTO,THEIMPLIEDWARRANTIESOFNON-INFRINGEMENT,MERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.Somejurisdictionsdonotallowdisclaimerof
expressorimpliedwarrantiesincertaintransactions,therefore,thisstatementmaynotapplytoyou.
Thisinformationcouldincludetechnicalinaccuraciesortypographicalerrors.Changesareperiodicallymadetotheinformationherein;thesechangeswillbeincorporatedinneweditionsofthepublication.Lenovomaymakeimprovementsand/orchangesintheproduct(s)and/ortheprogram(s)describedinthispublicationatanytimewithoutnotice.
Theproductsdescribedinthisdocumentarenotintendedforuseinimplantationorotherlifesupportapplicationswheremalfunctionmayresultininjuryordeathtopersons.TheinformationcontainedinthisdocumentdoesnotaffectorchangeLenovoproductspecificationsorwarranties.NothinginthisdocumentshalloperateasanexpressorimpliedlicenseorindemnityundertheintellectualpropertyrightsofLenovoorthirdparties.Allinformationcontainedinthisdocumentwasobtainedinspecificenvironmentsandispresentedasanillustration.Theresultobtainedinotheroperatingenvironmentsmayvary.Lenovomayuseordistributeanyoftheinformationyousupplyinanywayitbelievesappropriatewithoutincurringanyobligationtoyou.
Anyreferencesinthispublicationtonon-LenovoWebsitesareprovidedforconvenienceonlyanddonotinanymannerserveasanendorsementofthoseWebsites.ThematerialsatthoseWebsitesarenotpartofthematerialsforthisLenovoproduct,anduseofthoseWebsitesisatyourownrisk.Anyperformancedatacontainedhereinwasdeterminedinacontrolledenvironment.Therefore,theresultobtainedinotheroperatingenvironmentsmayvarysignificantly.Somemeasurementsmayhavebeenmadeondevelopment-levelsystemsandthereisnoguaranteethatthesemeasurementswillbethesameongenerallyavailablesystems.Furthermore,somemeasurementsmayhavebeenestimatedthroughextrapolation.Actualresultsmayvary.Usersofthisdocumentshouldverifytheapplicabledatafortheirspecificenvironment.
© Copy r ight Lenovo 2015. Al l r ights reserved.
8/9/2019 Tips 1242
57/57
ThisdocumentwascreatedorupdatedonMay7,2015.
Sendusyourcommentsinoneofthefollowingways:UsetheonlineContact us reviewformfoundat:ibm.com /redbooksSendyourcommentsinane-mailto:
Thisdocumentisavailableonlineathttp://lenovopress.com/tips1242.
Trademarks
Lenovo,ForThoseWhoDoandtheLenovologoaretrademarksorregisteredtrademarksofLenovointheUnitedStates,othercountries,orboth.TheseandotherLenovotrademarkedtermsaremarkedontheirfirstoccurrenceinthisinformationwiththeappropriatesymbol(®or™),indicatingUSregisteredorcommonlawtrademarksownedbyLenovoatthetimethisinformationwaspublished.Suchtrademarksmayalsoberegisteredorcommonlawtrademarksinothercountries.AcurrentlistofLenovotrademarksisavailableontheWebathttp://www.lenovo.com/legal/copytrade.html.
ThefollowingtermsaretrademarksofLenovointheUnitedStates,othercountries,orboth:
Lenovo®RackSwitch™Lenovo(logo)®ServeRAID™ServerProven®Systemx®ToolsCenter™TruDDR4™
Thefollowingtermsaretrademarksofothercompanies:
Intel,IntelXeon,Intellogo,IntelInsidelogo,andIntelCentrinologoaretrademarksorregisteredtrademarksofIntelCorporationoritssubsidiariesintheUnitedStatesandothercountries.
LinuxisatrademarkofLinusTorvaldsintheUnitedStates,othercountries,orboth.
Microsoft,Windows,andtheWindowslogoaretrademarksofMicrosoftCorporationintheUnitedStates,othercountries,orboth.
Othercompany,product,orservicenamesmaybetrademarksorservicemarksofothers.
mailto:[email protected]://lenovopress.com/tips1242http://www.lenovo.com/legal/copytrade.html.http://www.lenovo.com/legal/copytrade.html.http://www.lenovo.com/legal/copytrade.html.http://lenovopress.com/tips1242mailto:[email protected]