1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 Horsham Air Guard Station Note: AFFF or Aqueous Film Forming Foam is a product specially designed to suppress fires involving petroleum fuels. TIMELINE FOR USAGE OF FIRE-FIGHTING FOAM (AFFF) CONTAINING PFOS/PFOA AT THE HORSHAM AIR GUARD STATION. Base mission includes A-10. Air National Guard installs AFFF fire suppression systems in their hangars. F-14 Tomcat crash occurs off base during air show. Responded to by local fire departments and Navy (AFFF used for fire suppression). 3M ceases manufacture of AFFF with PFOS/PFOA. ANG uses 3M as sole provider of AFFF EPA establishes Provisional Health Advisory Levels for PFOS and PFOA BRAC realigns base On base testing of groundwater ANG begins Facility Investigation Two spills occur at Building 335. Total volume less than approximately 150 gallons per spill A-10 aircraft crash occurs. AFFF used for fire suppression Spill occurs at Building 201. Unknown volume. Spill occurs at Building 348. Estimated volume of approximately 1,000 gallons. AFFF shipped off base EPA issues Administrative Order to ANG

TIMELINE FOR USAGE OF FIRE-FIGHTING FOAM (AFFF) …

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015

Horsham Air Guard Station

Note: AFFF or Aqueous Film Forming Foam is a product specially designed to suppress fires involving petroleum fuels.

TIMELINE FOR USAGE OF FIRE-FIGHTING FOAM (AFFF) CONTAINING PFOS/PFOA AT THE HORSHAM AIR GUARD STATION.

Base mission includes A-10. Air National Guard installs AFFF fire suppression systems in their hangars.

F-14 Tomcat crash occurs off base during air show. Responded to by local fire departments and Navy (AFFF used for fire suppression).

3M ceases manufacture of AFFF with PFOS/PFOA. ANG uses 3M as sole provider of AFFF

EPA establishes Provisional Health Advisory Levels for PFOS and PFOA

BRAC realigns base

On base testing of groundwater

ANG begins Facility Investigation

Two spills occur at Building 335. Total volume less than approximately 150 gallons per spill

A-10 aircraft crash occurs. AFFF used for fire suppression

Spill occurs at Building 201. Unknown volume.

Spill occurs at Building 348. Estimated volume of approximately 1,000 gallons.

AFFF shipped off base

EPA issues Administrative Order to ANG

Horsham Air Guard Station

SAMPLING LOCATIONS AT HORSHAM AIR GUARD STATION

DATE: 5/9/2016FIGURE: 1PROJECT: \ANG_Horsham_PFCs\0_GIS\Projects|\FIWP\Actual_Location\Figure 1 Horsham Sample Locations_11x17.mxd

SAMPLING LOCATIONSAT HORSHAM AGS

HORSHAM AIR GUARD STATIONHORSHAM TOWNSHIP,

PENNSYLVANIA

&(

&(

&(

&(

&(

&(&(

&(&(

&<&<

&<

&< &<&<

&<

@?@?

@?

@?

@?

@?

@?

@?@?

@?

@? @?

@?

!(

!(

!(!(

!(

!(

!(

!(

!(!(!(

!(

!(!(

!(

!(

!(

!(

!(

!(!(

!(!(

!(

!(!(

!(!(

!(!(

!(

!(

!(

!(!(

!(!( !(!(

!(

!(!(

!(!(

!(!(

!(!(

!( !(!(!(

!(!(

!(

!(!( !(

@A @A@A @A@A

@A@A@A@A

@A@A

@A

@A

@A@A

@A@A

@A

@A@A@A

@A@A

@A

@A@A@A

@A

@A

@A@A

@A

@A @A@A

@A@A@A

@A

@A

@A@A

@A

@A

@A@A

@A

@A

Hawkeye

Ave

HornetAve

Prive

t RD

16th Ave

Privet

RD

Private Rd

Liberty Cir

Minot STNorton STMcGuire

ST

Intruder AVE

Robins ST

Eglin ST

Johnson ST

Eas

ton

AVE

Seasprite AVE

Fowler AVE

Griffiss S

T

Perimeter R

D

Langley ST

Andrews RD

Hor

net A

ve

Itami ST

Eas

ton

AVE

Fairc

hild S

T

Skyh

awk A

VE

County Line RD

207

314464

211

212234313

246

232

310227

301

213

307

320

345

230229 219

312

244

300

346

201

348

236

202

242

217235

335

214

350

216

239

237

240

351

1100

208

204

353

233203

355

243

248

249

231

354

AreaShown

NOTES:

LEGEND:

1. Additional monitoring well locations will be added pending results of analytical samples.2. An additional sediment sample was collected immediately downstream from the wastewater treatment outfall located along Park Creek at the County Line Road bridge.3. Source: Common Installation Picture (CIP) geodatabase provided by ANG GeoBase on 09/14/2015.4. Background Source: ESRI World Imagery (USDA NAIP, 06/2013).

40 200 400Feet

@AExisting GroundwaterMonitoring Well 1

!( Soil Boring

@? Surface Water Sample

@? Sediment Sample2

&<Sediment and SurfaceWater Sample

&(Approximate AFFF TankLocation

Stream3

Building3

Installation Boundary3

206238

Horsham Air Guard Station

HORSHAM AIR GUARD STATION SITE MAP

DATE: 12/21/2015FIGURE: 2PROJECT: \ANG_Horsham_PFCs\0_GIS\Projects|\FIWP\UFPQAPP\Figure 2 Site Map_11x17.mxd

HORSHAM AGSSITE MAP

HORSHAM AIR GUARD STATIONHORSHAM TOWNSHIP,

PENNSYLVANIA

207

209

314464

211

212234 313

246

310227

301

213

307

320

345

229 219

312

223

244

300

346

236

202

242

217235

214

350

216

239

237

240

351

1100

208

204

353

233

203

355

243

248

249

231

354

Prive

t RD

16th AveLiberty Cir

Haw

keye Ave

Minot STNorton ST

McGuire ST

Intruder AVE

Robins ST

Eglin ST

Johnson ST

Seasprite AVE

Fowler AVE

Griffiss

ST

Perimeter R

D

County Line RD

Langley ST

Andrews RD

Hor

net A

ve

Itami ST

Fairc

hild

ST

Eas

ton

AVE

Skyh

awk A

VE

206

StormwaterBasin

230

201

348

Privet RoadCompound 633

FormerWWTP

232

AreaShown

NOTES:

LEGEND:

* Source: Common Installation Picture (CIP) geodatabase provided by ANG GeoBase on 09/14/2015.1. Background Source: ESRI World Imagery (USDA NAIP, 06/2013).

40 300 600150Feet

Stream*

Potential PFC Source Areas

Building*

Installation*

335

238

18