7
Project description User Namai Position HECO - HCS - Timber construction design ® (1 By 7) Page 1 Project information Planned construction Deadline 2015.05.19 Item overview Description Article number Diameter Length 300 mm 8,5 mm 46838 TOPIX-CC 8,5 x 300 Type Cylinder head VE/piece 50 Number 12 Result Number of screws 12 TOPIX-CC 8,5 x 300 No pre-drilled 6 mm = Edge distance 48 mm = Screw distancce 40 mm = Edge distance 176 mm = Screw distancce 32 mm = Edge distance 90 ° = Screw-in angle Version: 3.0.2.33 HECO-Schrauben GmbH & Co.KG Dr.-Kurt-Steim-Strasse 28 D-78713 Schramberg Phone: +49 (0)7422 989-0 Fax: +49 (0)7422 989-200 2015.05.19

Timber Bearing Design

Embed Size (px)

DESCRIPTION

Timber construction design

Citation preview

  • Project description

    User Namai

    Position

    HECO - HCS - Timber construction design

    (1 By 7) Page 1

    Project information

    Planned construction

    Deadline 2015.05.19

    Item overview

    Description

    Article number

    Diameter

    Length 300 mm

    8,5 mm

    46838

    TOPIX-CC 8,5 x 300

    Type Cylinder head

    VE/piece 50

    Number 12

    Result

    Number of screws 12 TOPIX-CC 8,5 x 300

    Nopre-drilled

    6 mm=Edge distance

    48 mm=Screw distancce

    40 mm=Edge distance

    176 mm=Screw distancce

    32 mm=Edge distance

    90 =Screw-in angle

    Version: 3.0.2.33

    HECO-Schrauben GmbH & Co.KG

    Dr.-Kurt-Steim-Strasse 28 D-78713 Schramberg

    Phone: +49 (0)7422 989-0 Fax: +49 (0)7422 989-200 2015.05.19

  • Project description

    User Namai

    Position

    HECO - HCS - Timber construction design

    (2 By 7) Page 2

    Geometry

    CarrierGlulam, homogeneousMaterial

    GL28hClass of strength

    NoDouglas fir

    YesSpruce, pine or fir

    240= mmWidth

    500= mmHeight

    Pressure distribution panel16= mmThickness

    SupportEnd supportType

    240= mmWidth

    284= mmLength

    0= mmOverhang

    Screws0= mmMinimum distance from support edge

    Version: 3.0.2.33

    HECO-Schrauben GmbH & Co.KG

    Dr.-Kurt-Steim-Strasse 28 D-78713 Schramberg

    Phone: +49 (0)7422 989-0 Fax: +49 (0)7422 989-200 2015.05.19

  • Project description

    User Namai

    Position

    HECO - HCS - Timber construction design

    (3 By 7) Page 3

    Load

    Single load / line load with support distanceSupport reaction due to

    200= mmDistance of impact to support

    1Class of usage

    Permanent characteristic load108,00= kN

    1,35=Partial safety factor

    PermanentLoad effect duration class

    Variable characteristic load80,00= kN

    1,30=Partial safety factor

    MediumLoad effect duration class

    Version: 3.0.2.33

    HECO-Schrauben GmbH & Co.KG

    Dr.-Kurt-Steim-Strasse 28 D-78713 Schramberg

    Phone: +49 (0)7422 989-0 Fax: +49 (0)7422 989-200 2015.05.19

  • Project description

    User Namai

    Position

    HECO - HCS - Timber construction design

    (4 By 7) Page 4

    Static verification

    LCC1 Load case combination permanent

    LCC2 Load case combination permanent and variable

    Support pressure

    Aef = l * Min(bA; b)

    l [mm] bA [mm] b [mm] Aef [mm]

    314 240 240 75360

    c,90,d = Fc,90,dAef

    Fc,90,d [kN] Aef [mm] c,90,d [N/mm]145,80 75360 1,93LCC1

    249,80 75360 3,31LCC2

    fc,90,d = kmod * fc,90,kM

    Version: 3.0.2.33

    HECO-Schrauben GmbH & Co.KG

    Dr.-Kurt-Steim-Strasse 28 D-78713 Schramberg

    Phone: +49 (0)7422 989-0 Fax: +49 (0)7422 989-200 2015.05.19

  • Project description

    User Namai

    Position

    HECO - HCS - Timber construction design

    (5 By 7) Page 5

    kmod f c,90,k [N/mm] M f c,90,d [N/mm]0,60 3,00 1,30 1,38LCC1

    0,80 3,00 1,30 1,85LCC2

    = c,90,dkc,90 * fc,90,d

    * 100%

    c,90,d [N/mm] kc,90 f c,90,d [N/mm] [%]1,93 1,00 1,38 139,73LCC1

    3,31 1,00 1,85 179,55LCC2

    Support pressure with reinforcement

    Fax,,Rk = n * fax,k * d1 * lef

    1,2 * cos + sin * (k

    350)

    0.8

    n fax,k [N/mm] d1 [mm] lef [mm]

    1 12,50 8,0 292

    [] k [kg/m] Fax,,Rk [kN]90 410 33,13

    Fax,,Rd = kmod * Fax,,Rk

    Mkmod Fax,,Rk [kN] M Fax,,Rd [kN]0,60 33,13 1,30 15,29LCC1

    0,80 33,13 1,30 20,38LCC2

    Npl,k = * d21

    4 * fy,k

    d1 [mm] f y,k [N/mm] Npl,k [kN]

    4,85 900 16,63

    Npl,d = Npl,kM

    Npl,k [kN] M Npl,d [kN]16,63 1,10 15,12

    Version: 3.0.2.33

    HECO-Schrauben GmbH & Co.KG

    Dr.-Kurt-Steim-Strasse 28 D-78713 Schramberg

    Phone: +49 (0)7422 989-0 Fax: +49 (0)7422 989-200 2015.05.19

  • Project description

    User Namai

    Position

    HECO - HCS - Timber construction design

    (6 By 7) Page 6

    R90,d,1 = kc,90 * B * lef,1 * fc,90,d + n * Min(Fax,,Rd; c * Npl,d)kc,90 B [mm] lef,1 [mm] f c,90,d [N/mm]

    1,00 240 314 1,38LCC1

    1,00 240 314 1,85LCC2

    n Fax,,Rd [kN] c Npl,d [kN]12 15,29 0,66 15,12LCC1

    12 20,38 0,66 15,12LCC2

    R90,d,1 [kN]

    224,24LCC1

    259,02LCC2

    R90,d,2 = B * lef,2 * fc,90,d

    B [mm] lef,2 [mm] f c,90,d [N/mm] R90,d,2 [kN]

    240 578 1,38 192,07LCC1

    240 578 1,85 256,10LCC2

    R90,d = Min(R90,d,1; R90,d,2)

    R90,d,1 [kN] R90,d,2 [kN] R90,d [kN]

    224,24 192,07 192,07LCC1

    259,02 256,10 256,10LCC2

    = VdR90,d

    * 100%

    Vd [kN] R90,d [kN] [%]145,80 192,07 75,91LCC1

    249,80 256,10 97,54LCC2

    Support pressure179,55%=

    Support pressure with reinforcement97,54%=

    The screw is suitable for the selected system.

    Version: 3.0.2.33

    HECO-Schrauben GmbH & Co.KG

    Dr.-Kurt-Steim-Strasse 28 D-78713 Schramberg

    Phone: +49 (0)7422 989-0 Fax: +49 (0)7422 989-200 2015.05.19

  • Project description

    User Namai

    Position

    HECO - HCS - Timber construction design

    (7 By 7) Page 7

    Construction notes

    1. Determination pursuant to DIN EN 1995-1-1 2010-12 & DIN EN 1995-1-1/NA 2010-12 inconnection with approval number ETA-12/0132 for HECO TOPIX-CC full-thread screws as woodconnection media.

    2. The screws may only be used for static or quasi-static loads. 3. Wood moisture content must be less than 20%. 4. The loads transferred by the screw forces must be taken up without deformation of the support. 5. All calculations must be verified and cleared before performance by the responsible bearing

    structure planner.

    Version: 3.0.2.33

    HECO-Schrauben GmbH & Co.KG

    Dr.-Kurt-Steim-Strasse 28 D-78713 Schramberg

    Phone: +49 (0)7422 989-0 Fax: +49 (0)7422 989-200 2015.05.19